Linkplay Technology Inc. AMP003 WiiM Amp Ultra 2BABF-AMP003 2BABFAMP003 amp003
REPORT No.SZ25020263W01 TEST REPORT APPLICANT : Linkplay Technology Inc. PRODUCT NAME : WiiM Amp Ultra MODEL NAME : AMP003 BRAND NAME : WiiM FCC ID : 2BABF-AMP003 STANDARD(S) : 47 CFR Part 15 Subpart C RECEIPT DATE : 2025-03-19 TEST DATE : 2025-04-15 to 2025-05-09 ISSUE DATE : 2025-05-19 Edited by: Zeng Xiaoying (Rapporteur) Approved by: Shen Junsheng (Supervisor) NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 1 of 36 REPORT No.SZ25020263W01 DIRECTORY 1. Summary of Test Result 3 1.1. Testing Applied Standards 4 1.2. Test Equipment List 5 1.3. Measurement Uncertainty 7 1.4. Testing Laboratory7 2. General Description 8 2.1. Information of Applicant and Manufacturer 8 2.2. Information of EUT8 2.3. Channel List of EUT 9 2.4. Test Configuration of EUT 10 2.5. Test Conditions 10 2.6. Test Setup Layout Diagram 10 3. Test Results 13 3.1. Conducted Emission 13 3.2. Restricted Frequency Bands 14 3.3. Radiated Emission 15 Annex A Test Data and Result 17 Version 1.0 Change History Date 2025-05-19 Reason for change First edition MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 2 of 36 1. Summary of Test Result REPORT No.SZ25020263W01 No. Section Description Test Date Test Engineer Result Method Determination /Remark 1 15.203 Antenna Requirement N/A N/A N/ANote1 N/A 2 N/A Duty Cycle of Test Signal N/A N/A N/ANote1 N/A Maximum Peak 3 15.247(b) Conducted N/A Output Power N/A N/ANote1 N/A Maximum 4 15.247(b) Average Conducted N/A N/A N/ANote1 N/A Output Power 5 15.247(a) Bandwidth N/A N/A N/ANote1 N/A Conducted 6 15.247(d) Spurious Emission and N/A N/A N/ANote1 N/A Band Edge 7 15.247(e) Power Spectral Density N/A N/A N/ANote1 N/A 8 15.207 Conducted Emission May 09, 2025 Fan Shengquan PASS No deviation Restricted 9 15.247(d) Frequency Apr. 09, 2025 Gao Jianrou PASS No deviation Bands 10 15.209, 15.247(d) Radiated Emission Apr. 23, 2025 Gao Jianrou PASS No deviation Note 1: The test results of all conducted test items please refer to the module FCC test report (Report No.: SZ24040154W01), which issued on Jul. 26, 2024. Note 2: The tests were performed according to the method of measurements prescribed in ANSI C63.10-2013 and KDB 558074 D01 v05r02. Note 3: Additions to, deviation, or exclusions from the method shall be judged in the "method determination" column of add, deviate or exclude from the specific method shall be explained in the "Remark" of the above table. Note 4: When the test result is a critical value, we will use the measurement uncertainty give the MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 3 of 36 REPORT No.SZ25020263W01 judgment result based on the 95% confidence intervals. 1.1. Testing Applied Standards According to the specifications of the manufacturer, the EUT must comply with the requirements of the following standards: 47 CFR Part 15 Subpart C Radio Frequency Devices MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 4 of 36 1.2. Test Equipment List REPORT No.SZ25020263W01 1.2.1 Conducted Emission Test Equipment Equipment Serial No. Type Receiver MY56400093 N9038A LISN 8127449 Pulse Limiter (10dB) RF Coaxial Cable (DC-100MHz) VTSD 9561 FB #206 BNC NSLK 8127 VTSD 9561-F MRE04 Manufacturer KEYSIGHT Cal. Date Due Date 2025.01.06 2026.01.05 Schwarzbeck 2025.01.09 2026.01.08 Schwarzbeck 2024.05.30 2025.05.29 Qualwave 2024.07.02 2025.07.01 1.2.2 List of Software Used Description JS32-RE TS+ -[JS32-CE] Manufacturer Tonscend Tonscend Software Version 5.0.0 2.5.0.0 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 5 of 36 REPORT No.SZ25020263W01 1.2.4 Radiated Test Equipment Equipment Serial No. Signal Analyzer MY56060145 Test Antenna - BiLog 9163-519 Test Antenna Loop 1519-022 Test Antenna Horn 01774 Test Antenna BBHA9170 Horn #773 Preamplifier (10MHz-6GHz) 46732 Preamplifier (2GHz-18GHz) 61171/61172 Preamplifier (18GHz-40GHz) DS77209 Type N9020A VULB 9163 FMZB1519 BBHA 9120D BBHA9170 S10M100L38 02 S020180L32 03 DCLNA0118- 40C-S RF Coaxial Cable (DC-18GHz) MRE001 PE330 RF Coaxial Cable (DC-18GHz) RF Coaxial Cable (DC-18GHz) RF Coaxial Cable (DC-40GHz) RF Coaxial Cable (DC-40GHz) RF Coaxial Cable (DC-18GHz) Notch Filter Anechoic Chamber Anechoic Chamber MRE002 MRE003 22290045 22290046 22120181 N/A N/A N/A CLU18 CLU18 QA360-40KK-0.5 QA360-40KKF-2 QA500-18NN-5 WRCG-24002483.5-60SS 9m*6m*6m 9m*6m*6m Manufacturer Agilent Schwarzbeck Schwarzbeck Schwarzbeck Schwarzbeck LUCIX CORP. LUCIX CORP. Decentest Pasternack Pasternack Pasternack Qualwave Qualwave Qualwave Wainwright CRT CRT Cal. Date 2024.05.30 2024.06.22 2024.06.03 2024.06.22 2024.06.22 2024.05.30 2024.05.30 2024.05.30 2024.05.30 2024.05.30 2024.05.30 2024.07.03 2024.07.03 2024.07.03 N/A 2025.04.19 2022.11.30 Due Date 2025.05.29 2025.06.21 2025.06.02 2025.06.21 2025.06.21 2025.05.29 2025.05.29 2025.05.29 2025.05.29 2025.05.29 2025.05.29 2025.07.02 2025.07.02 2025.07.02 N/A 2028.04.18 2025.11.29 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 6 of 36 1.3. Measurement Uncertainty REPORT No.SZ25020263W01 Test Items Restricted Frequency Bands Radiated Emission Conducted Emission 1.4. Testing Laboratory Uncertainty ±5% ±2.95dB ±2.44dB Remark Confidence levels of 95% Confidence levels of 95% Confidence levels of 95% Laboratory Name Laboratory Address Telephone Facsimile FCC Designation Number FCC Test Firm Registration Number Shenzhen Morlab Communications Technology Co., Ltd. FL.3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China +86 755 36698555 +86 755 36698525 CN1192 226174 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 7 of 36 2. General Description REPORT No.SZ25020263W01 2.1. Information of Applicant and Manufacturer Applicant Applicant Address Manufacturer Manufacturer Address Linkplay Technology Inc. 8000 Jarvis Avenue Suite #130, Newark, CA 94560 Linkplay Technology Inc. 8000 Jarvis Avenue Suite #130, Newark, CA 94560 2.2. Information of EUT Product Name: WiiM Amp Ultra Sample No.: 4#, 25# Hardware Version: A98D V02+Main Board V02 Software Version: Linkplay.5.2.708867 Equipment Type: Bluetooth LE Bluetooth Version: 5.3 Modulation Type: GFSK Data Rate: 1Mbps, 2Mbps Operating Frequency Range: 2402MHz-2480MHz Antenna Type: PIFA Antenna Antenna Gain: ANT1: 3.46dBi; ANT2: 3.46dBi Note 1: The test results of all conducted test items please refer to the module FCC test report (Report No.: SZ24040154W01), which issued on Jul. 26, 2024. We only recorded the radiated test result in this report. Note 2: The EUT has two antennas and it operates in single antenna. Both of the two antennas were evaluated separately, only the worst test result (ANT2) were recorded in the test report. Note 3: For a more detailed description, please refer to Specification or User's Manual supplied by the applicant and/or manufacturer. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 8 of 36 2.3. Channel List of EUT REPORT No.SZ25020263W01 Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) 0 2402 10 2422 20 2442 30 2462 1 2404 11 2424 21 2444 31 2464 2 2406 12 2426 22 2446 32 2466 3 2408 13 2428 23 2448 33 2468 4 2410 14 2430 24 2450 34 2470 5 2412 15 2432 25 2452 35 2472 6 2414 16 2434 26 2454 36 2474 7 2416 17 2436 27 2456 37 2476 8 2418 18 2438 28 2458 38 2478 9 2420 19 2440 29 2460 39 2480 Note 1: The black bold channels were selected for test. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 9 of 36 2.4. Test Configuration of EUT REPORT No.SZ25020263W01 Test mode is used to control the EUT under the maximum power level during test. 2.5. Test Conditions Temperature (°C) Relative Humidity (%) Atmospheric Pressure (kPa) 15-35 30-60 86-106 2.6. Test Setup Layout Diagram 2.6.1.Conducted Emission Measurement MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 10 of 36 2.6.2.Radiation Measurement 1) For radiated emissions from 9kHz to 30MHz REPORT No.SZ25020263W01 2) For radiated emissions from 30MHz to1GHz MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 11 of 36 3) For radiated emissions above 1GHz REPORT No.SZ25020263W01 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 12 of 36 3. Test Results REPORT No.SZ25020263W01 3.1. Conducted Emission 3.1.1.Requirement According to FCC section 15.207, for an intentional radiator that is designed to be connected to the public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in the following table, as measured using a 50µH/50 line impedance stabilization network (LISN). Frequency Range (MHz) Conducted Limit (dBµV) Quai-peak Average 0.15 - 0.50 66 to 56 56 to 46 0.50 - 5 56 46 5 - 30 60 50 Note: (a) The lower limit shall apply at the band edges. (b) The limit decreases linearly with the logarithm of the frequency in the range 0.15 - 0.50MHz. 3.1.2.Test Procedures The Table-top EUT was placed upon a non-metallic table 0.8m above the horizontal metal reference ground plane. EUT was connected to LISN and LISN was connected to reference Ground Plane. EUT was 80cm from LISN. The set-up and test methods were according to ANSI C63.10: 2013. 3.1.3.Test Setup Layout Refer to chapter 2.6.2 in this report. 3.1.4.Test Result Refer to Annex A.1 in this report. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 13 of 36 3.2. Restricted Frequency Bands REPORT No.SZ25020263W01 3.2.1.Requirement According to FCC section 15.247(d), in any 100kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20dB below that in the 100kHz bandwidth within the band that contains the highest level of the desired power, In addition, radiated emissions which fall in the restricted bands, as defined in 15.205(a), must also comply with the radiated emission limits specified in 15.209(a). 3.2.2.Test Procedures The EUT is located in a 3m Semi-Anechoic Chamber; the antenna factors, cable loss and so on of the site as factors are calculated to correct the reading. For the Test Antenna: Test Antenna is 3m away from the EUT. Test Antenna height is varied from 1m to 4m above the ground to determine the maximum value of the field strength. Span = wide enough to fully capture the emission being measured RBW = 1 MHz for f 1GHz, 100 kHz for f < 1GHz VBW = 3 MHz Sweep = auto Detector function = peak/average Trace = max hold Allow the trace to stabilize 3.2.3.Test Setup Layout Refer to chapter 2.6.3 in this report. 3.2.4.Test Result Refer to Annex A.2 in this report. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 14 of 36 3.3. Radiated Emission REPORT No.SZ25020263W01 3.3.1.Requirement According to FCC section 15.247(d), radiated emission outside the frequency band attenuation below the general limits specified in FCC section 15.209(a) is not required. In addition, radiated emissions which fall in the restricted bands, as defined in FCC section 15.205(a), must also comply with the radiated emission limits specified in FCC section 15.209(a). According to FCC section 15.209 (a), except as provided elsewhere in this subpart, the emissions from an intentional radiator shall not exceed the field strength levels specified in the following table: Frequency (MHz) Field Strength (µV/m) Measurement Distance (m) 0.009 - 0.490 2400/F(kHz) 300 0.490 - 1.705 24000/F(kHz) 30 1.705 - 30.0 30 30 30 - 88 100 3 88 - 216 150 3 216 - 960 200 3 Above 960 500 3 Note1: For above 1000MHz, the emission limit in this paragraph is based on measurement instrumentation employing an average detector, measurement using instrumentation with a peak detector function, corresponding to 20dB above the maximum permitted average limit. Note2:For above 1000MHz, limit field strength of harmonics: 54dBuV/m@3m (AV) and 74dBuV/m@3m (PK).In addition, radiated emissions which fall in the restricted bands, as defined in Section 15.205(a), also should comply with the radiated emission limits specified in Section 15.209(a)(above table). MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 15 of 36 REPORT No.SZ25020263W01 3.3.2.Test Procedures The EUT is placed on a non-conducting table 80 cm above the ground plane for measurement below 1GHz; 1.5 m above the ground plane for measurement above 1GHz.The antenna to EUT distance is 3meters. The EUT is configured in accordance with ANSI C63.10. The EUT is set to transmit in a continuous mode. For measurements below 30MHz, the emission limits shown in the above table are based on measurements employing a CISPR quasi-peak detector except for the frequency bands 9kHz-90 kHz, 110kHz-490 kHz. Radiated emission limits in these two bands are based on measurements employing an average detector. For measurements below 1GHz the resolution bandwidth is set to 100kHz for peak detection measurements or 120kHz for quasi-peak detection measurements. Peak detection is used unless otherwise noted as quasi-peak. For measurements above 1GHz the resolution bandwidth is set to 1MHz, the video band width is set to 3MHz for peak measurements and as applicable for average measurements. The EUT is rotated through 360 degrees to maximize emissions received. The antenna is scanned from 1 to 4 meters above the ground plane to further maximize the emission. Measurements are made with the antenna polarized in both the vertical and the horizontal positions. For measurements above 1 GHz, keeping the measurement antenna aimed at the source of emissions at each frequency of significant emissions, with polarization oriented for maximum response. 3.3.3.Test Setup Layout Refer to chapter 2.6.3 in this report. 3.3.4.Test Result Refer to Annex A.3 in this report. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 16 of 36 REPORT No.SZ25020263W01 Annex A Test Data and Result A.1. Conducted Emission The maximum conducted interference is searched using Peak (PK), if the emission levels more than the AV and QP limits, and that have narrow margins from the AV and QP limits will be remeasured with AV and QP detectors. Tests for both L phase and N phase lines of the power mains connected to the EUT are performed. Set RBW=9kHz, VBW=30kHz. Refer to recorded points and plots below. Note: Both of the test voltage AC 120V/60Hz and AC 230V/50Hz were considered and tested respectively, only the results of the worst case AC 120V/60Hz were recorded in this report. A. Test Setup: Test Mode: EUT+TV+HDMl cable+Load+Fiber box+Mobile phone+Audio+U disk+BT TX Test voltage: AC 120V/60Hz The measurement results are obtained as below: E [dBV] =UR + LCable loss [dB] + AFactor UR: Receiver Reading AFactor: Voltage division factor of LISN MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 17 of 36 B. Test Plot: REPORT No.SZ25020263W01 (L Phase) No. Fre. (MHz) Emission Level (dBµV) Quai-peak Average 1 0.1590 48.77 29.17 2 0.2895 42.55 27.22 3 0.4200 43.55 26.46 4 0.5640 33.71 22.21 5 0.6989 32.44 21.50 6 9.7297 27.73 17.75 Limit (dBµV) Quai-peak 65.52 60.54 57.45 56.00 56.00 60.00 Average 55.52 50.54 47.45 46.00 46.00 50.00 Power-line Verdict PASS PASS Line PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 18 of 36 REPORT No.SZ25020263W01 (N Phase) No. Fre. (MHz) Emission Level (dBµV) Quai-peak Average 1 0.2445 39.42 25.47 2 0.2580 39.95 25.81 3 0.3975 44.86 26.59 4 0.5370 31.97 21.37 5 7.4540 29.87 15.18 6 18.2432 40.50 37.11 Limit (dBµV) Quai-peak 61.94 61.49 57.91 56.00 60.00 60.00 Average 51.94 51.49 47.91 46.00 50.00 50.00 Power-line Verdict Neutral PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 19 of 36 REPORT No.SZ25020263W01 A.2. Restricted Frequency Bands Note: Restricted Frequency Bands were performed when antenna was at vertical and horizontal polarity, and only the worse test condition (Vertical) was recorded in this test report. 1Mbps Plot for Channel 0 Fre. (MHz) 2324.11 2333.52 2351.84 2355.25 2374.36 2375.17 Reading [dBV] 12.9 -0.3 12.0 -0.2 13.5 0.5 Level [dBV/m] 45.01 31.99 44.44 32.18 45.96 33.00 Factor [dB/m] 32.150 32.240 32.400 32.420 32.490 32.490 Limit [dBV/m] 74.00 54.00 74.00 54.00 74.00 54.00 Margin [dB] 28.99 22.01 29.56 21.82 28.04 21.00 Height [cm] 150 150 150 150 150 150 Angle [°] 352 224 360 185 224 312 Detector PK AV PK AV PK AV Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 20 of 36 Plot for Channel 39 REPORT No.SZ25020263W01 Fre. (MHz) 2483.50 2484.48 2489.69 2489.77 2494.63 2494.68 Reading [dBV] 7.0 18.3 5.5 17.8 17.7 5.4 Level [dBV/m] 39.98 51.33 38.49 50.82 50.66 38.37 Factor [dB/m] 33.030 33.030 33.020 33.020 33.010 33.010 Limit [dBV/m] 54.00 74.00 54.00 74.00 74.00 54.00 Margin [dB] 14.02 22.67 15.51 23.18 23.34 15.63 Height [cm] 150 150 150 150 150 150 Angle [°] 195 175 308 53 206 1 Detector AV PK AV PK PK AV Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 21 of 36 2Mbps Plot for Channel 0 REPORT No.SZ25020263W01 Fre. (MHz) 2332.22 2338.93 2368.76 2375.07 2376.37 2387.68 Reading [dBV] 12.5 -0.2 -0.4 0.5 12.5 12.1 Level [dBV/m] 44.71 32.09 32.12 32.95 44.99 44.65 Factor [dB/m] 32.230 32.290 32.470 32.490 32.490 32.540 Limit [dBV/m] 74.00 54.00 54.00 54.00 74.00 74.00 Margin [dB] 29.29 21.91 21.88 21.05 29.01 29.35 Height [cm] 150 150 150 150 150 150 Angle [°] 203 349 242 232 194 0 Detector PK AV AV AV PK PK Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 22 of 36 Plot for Channel 39 REPORT No.SZ25020263W01 Fre. (MHz) 2483.95 2484.04 2486.42 2487.87 2488.76 2493.36 Reading [dBV] 17.4 5.7 19.8 18.4 5.7 5.6 Level [dBV/m] 50.40 38.76 52.84 51.46 38.71 38.63 Factor [dB/m] 33.030 33.030 33.030 33.020 33.020 33.010 Limit [dBV/m] 74.00 54.00 74.00 74.00 54.00 54.00 Margin [dB] 23.60 15.24 21.16 22.54 15.29 15.37 Height [cm] 150 150 150 150 150 150 Angle [°] 183 225 173 195 22 11 Detector PK AV PK PK AV AV Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 23 of 36 REPORT No.SZ25020263W01 A.3. Radiated Emission According to ANSI C63.10, because of peak detection will yield amplitudes equal to or greater than amplitudes measured with the quasi-peak (or average) detector, the measurement data from a spectrum analyzer peak detector will represent the worst-case results, if the peak measured value complies with the quasi-peak (or average) limit, it is unnecessary to perform an quasi-peak measurement (or average). The measurement results are obtained as below: E [dBV/m] =UR + AT + AFactor [dB]; AT =LCable loss [dB]-Gpreamp [dB] AT: Total correction Factor except Antenna UR: Receiver Reading Gpreamp: Preamplifier Gain AFactor: Antenna Factor at 3m During the test, the total correction Factor AT and AFactor were built in test software. Note1: All radiated emission tests were performed in X, Y, Z axis direction. And only the worst axis test condition was recorded in this test report. Note2: For the frequency, which started from 9kHz to 30MHz, was pre-scanned and the result which was 20dB lower than the limit was not recorded. Note3: For the frequency, which started from 18GHz to 10th harmonic of the highest frequency, was pre-scanned and the result which was 20dB lower than the limit was not recorded. Note 4: All test modes were considered and evaluated respectively by performing full test, only the worst data were recorded. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 24 of 36 1Mbps Plot for Channel 0 REPORT No.SZ25020263W01 Fre. (MHz) 55.85 104.74 163.92 250.01 531.13 798.42 (Antenna Horizontal, 30MHz to 1GHz) Reading [dBV] 62.0 67.6 66.9 66.6 53.6 42.2 Level [dBV/m] 33.98 38.29 35.87 39.11 34.62 27.65 Factor [dB/m] -28.010 -29.300 -31.050 -27.490 -18.930 -14.570 Limit [dBV/m] 40.00 43.50 43.50 46.00 46.00 46.00 Margin [dB] 6.02 5.21 7.63 6.89 11.38 18.35 Height [cm] 150 150 150 150 150 150 Angle [°] 334 341 178 359 164 348 Detector PK PK PK PK PK PK Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 25 of 36 REPORT No.SZ25020263W01 (Antenna Horizontal, 1GHz to 18GHz) Fre. (MHz) 1061.21 1061.61 2472.69 2473.89 3202.72 3203.15 5669.22 5706.08 10615.07 10713.65 14477.47 14672.48 Reading [dBV] 37.0 49.0 28.5 40.4 54.6 51.5 36.5 46.0 31.4 40.5 36.5 26.8 Level [dBV/m] 34.36 46.33 34.36 46.26 43.67 40.58 35.37 45.25 43.59 52.80 56.06 47.37 Factor [dB/m] -2.660 -2.640 5.910 5.900 -10.880 -10.880 -1.100 -0.760 12.150 12.330 19.550 20.530 Limit [dBV/m] 54.00 74.00 54.00 74.00 74.00 54.00 54.00 74.00 54.00 74.00 74.00 54.00 Margin [dB] 19.64 27.67 19.64 27.74 30.33 13.42 18.63 28.75 10.41 21.20 17.94 6.63 Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150 Angle [°] 1 1 193 90 158 158 319 158 185 130 76 9 Detector AV PK AV PK PK AV AV PK AV PK PK AV Verdict PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 26 of 36 REPORT No.SZ25020263W01 Fre. (MHz) 30.58 52.99 104.74 163.96 532.53 749.97 (Antenna Vertical, 30MHz to 1GHz) Reading [dBV] 67.3 61.8 62.8 62.2 54.4 51.2 Level [dBV/m] 36.56 34.06 33.50 31.12 35.42 36.38 Factor [dB/m] -30.750 -27.770 -29.300 -31.040 -18.990 -14.840 Limit [dBV/m] 40.00 40.00 43.50 43.50 46.00 46.00 Margin [dB] 3.44 5.94 10.00 12.38 10.58 9.62 Height [cm] 150 150 150 150 150 150 Angle [°] 241 347 130 72 220 340 Detector PK PK PK PK PK PK Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 27 of 36 REPORT No.SZ25020263W01 (Antenna Vertical, 1GHz to 18GHz) Fre. (MHz) 1119.22 1127.23 2402.28 2418.68 3202.72 3203.15 5219.63 5220.92 7992.57 7996.86 14684.05 14738.48 Reading [dBV] 33.1 44.5 30.6 39.7 60.0 57.2 49.4 41.8 35.1 44.7 26.6 37.1 Level [dBV/m] 30.87 42.33 35.89 45.20 49.09 46.34 46.04 38.51 40.19 49.78 47.19 57.33 Factor [dB/m] -2.190 -2.140 5.250 5.500 -10.880 -10.880 -3.330 -3.310 5.050 5.120 20.560 20.270 Limit [dBV/m] 54.00 74.00 54.00 74.00 74.00 54.00 74.00 54.00 54.00 74.00 54.00 74.00 Margin [dB] 23.13 31.67 18.11 28.80 24.91 7.66 27.96 15.49 13.81 24.22 6.81 16.67 Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150 Angle [°] 137 132 148 170 76 64 130 130 64 64 117 330 Detector AV PK AV PK PK AV PK AV AV PK AV PK Verdict PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 28 of 36 Plot for Channel 19 REPORT No.SZ25020263W01 Fre. (MHz) 55.90 104.74 163.96 331.78 531.95 749.97 (Antenna Horizontal, 30MHz to 1GHz) Reading [dBV] 62.3 67.6 66.8 58.5 55.9 50.6 Level [dBV/m] 34.30 38.34 35.79 34.15 36.97 35.74 Factor [dB/m] -28.020 -29.300 -31.040 -24.390 -18.970 -14.840 Limit [dBV/m] 40.00 43.50 43.50 46.00 46.00 46.00 Margin [dB] 5.70 5.16 7.71 11.85 9.03 10.26 Height [cm] 150 150 150 150 150 150 Angle [°] 0 295 209 40 174 281 Detector PK PK PK PK PK PK Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 29 of 36 REPORT No.SZ25020263W01 (Antenna Horizontal, 1GHz to 18GHz) Fre. (MHz) 1040.01 1114.42 2440.29 2473.49 3253.29 3253.72 5213.21 5214.49 11093.80 11125.52 14690.05 14691.76 Reading [dBV] 36.5 46.8 33.6 39.5 53.1 50.4 47.8 40.6 30.2 40.0 26.9 35.5 Level [dBV/m] 33.69 44.57 39.46 45.45 41.76 39.04 44.40 37.18 44.22 53.96 47.48 56.12 Factor [dB/m] -2.820 -2.230 5.820 5.910 -11.310 -11.310 -3.440 -3.420 14.000 13.920 20.570 20.580 Limit [dBV/m] 54.00 74.00 74.00 74.00 54.00 74.00 54.00 54.00 74.00 54.00 74.00 Margin [dB] 20.31 29.43 28.55 32.24 14.96 29.60 16.82 9.78 20.04 6.52 17.88 Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150 Angle [°] 1 160 132 241 250 250 24 24 184 116 9 24 Detector AV PK AV PK PK AV PK AV AV PK AV PK Verdict PASS PASS NA PASS PASS PASS PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 30 of 36 REPORT No.SZ25020263W01 Fre. (MHz) 30.63 52.60 101.88 164.50 331.78 531.03 (Antenna Vertical, 30MHz to 1GHz) Reading [dBV] 65.8 61.9 63.3 63.2 55.5 49.5 Level [dBV/m] 35.06 34.09 33.66 31.97 31.15 30.61 Factor [dB/m] -30.750 -27.850 -29.600 -31.220 -24.390 -18.930 Limit [dBV/m] 40.00 40.00 43.50 43.50 46.00 46.00 Margin [dB] 4.94 5.91 9.84 11.53 14.85 15.39 Height [cm] 150 150 150 150 150 150 Angle [°] 210 288 118 32 309 210 Detector PK PK PK PK PK PK Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 31 of 36 REPORT No.SZ25020263W01 (Antenna Vertical, 1GHz to 18GHz) Fre. (MHz) 1063.61 1063.61 2439.89 2440.29 3253.29 3253.72 6361.81 6364.81 11108.37 11110.52 14703.33 14711.91 Reading [dBV] 46.6 36.2 43.0 40.0 56.9 55.4 48.2 39.1 40.4 30.0 26.6 35.8 Level [dBV/m] 43.96 33.53 48.81 45.84 45.63 44.10 49.38 40.25 54.47 44.00 47.15 56.27 Factor [dB/m] -2.640 -2.640 5.820 5.820 -11.310 -11.310 1.160 1.140 14.030 14.020 20.570 20.500 Limit [dBV/m] 74.00 54.00 74.00 54.00 74.00 54.00 74.00 54.00 54.00 74.00 Margin [dB] 30.04 20.47 28.37 9.90 24.62 13.75 19.53 10.00 6.85 17.73 Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150 Angle [°] 55 55 142 142 64 144 157 144 170 264 345 184 Detector PK AV PK AV PK AV PK AV PK AV AV PK Verdict PASS PASS NA NA PASS PASS PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 32 of 36 Plot for Channel 39 REPORT No.SZ25020263W01 Fre. (MHz) 56.00 104.74 164.50 250.01 533.16 916.67 (Antenna Horizontal, 30MHz to 1GHz) Reading [dBV] 62.1 66.9 69.1 68.2 55.6 41.4 Level [dBV/m] 34.09 37.57 37.86 40.75 36.60 29.42 Factor [dB/m] -28.050 -29.300 -31.220 -27.490 -19.020 -11.930 Limit [dBV/m] 40.00 43.50 43.50 46.00 46.00 46.00 Margin [dB] 5.91 5.93 5.64 5.25 9.40 16.58 Height [cm] 150 150 150 150 150 150 Angle [°] 359 334 207 359 137 87 Detector PK PK PK PK PK PK Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 33 of 36 REPORT No.SZ25020263W01 (Antenna Horizontal, 1GHz to 18GHz) Fre. (MHz) 1053.61 1054.01 2413.48 2471.49 3306.44 3307.29 5219.63 5222.21 7579.85 7591.85 14538.76 14685.76 Reading [dBV] 47.5 35.2 40.7 28.3 50.9 46.8 48.8 41.6 44.8 34.7 36.9 26.5 Level [dBV/m] 44.78 32.45 46.09 34.19 39.86 35.78 45.51 38.34 49.54 39.55 56.87 47.05 Factor [dB/m] -2.720 -2.700 5.420 5.910 -11.000 -10.990 -3.330 -3.290 4.750 4.860 20.010 20.560 Limit [dBV/m] 74.00 54.00 74.00 54.00 74.00 54.00 74.00 54.00 74.00 54.00 74.00 54.00 Margin [dB] 29.22 21.55 27.91 19.81 34.14 18.22 28.49 15.66 24.46 14.45 17.13 6.95 Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150 Angle [°] 351 351 324 166 265 265 144 144 184 360 169 9 Detector PK AV PK AV PK AV PK AV PK AV PK AV Verdict PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 34 of 36 REPORT No.SZ25020263W01 Fre. (MHz) 30.63 62.55 184.33 282.60 533.16 750.02 (Antenna Vertical, 30MHz to 1GHz) Reading [dBV] 65.8 63.3 63.0 60.7 51.4 45.4 Level [dBV/m] 35.01 34.48 32.90 34.43 32.35 30.52 Factor [dB/m] -30.750 -28.790 -30.090 -26.310 -19.020 -14.840 Limit [dBV/m] 40.00 40.00 43.50 46.00 46.00 46.00 Margin [dB] 4.99 5.52 10.60 11.57 13.65 15.48 Height [cm] 150 150 150 150 150 150 Angle [°] 159 68 245 273 173 102 Detector PK PK PK PK PK PK Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 35 of 36 REPORT No.SZ25020263W01 (Antenna Vertical, 1GHz to 18GHz) Fre. (MHz) 1183.24 1266.05 2464.69 2480.30 3306.87 3307.29 7089.55 7201.41 10534.93 11098.95 14470.61 14706.33 Reading [dBV] 31.5 43.3 39.4 31.6 53.7 49.2 44.8 34.4 40.8 30.1 36.8 26.3 Level [dBV/m] 30.13 41.95 45.33 37.48 42.66 38.16 48.93 39.50 52.85 44.14 56.24 46.88 Factor [dB/m] -1.380 -1.300 5.930 5.890 -11.000 -10.990 4.140 5.100 12.030 14.060 19.470 20.540 Limit [dBV/m] 54.00 74.00 74.00 54.00 74.00 54.00 74.00 54.00 74.00 54.00 74.00 54.00 Margin [dB] 23.87 32.05 28.67 16.52 31.34 15.84 25.07 14.50 21.15 9.86 17.76 7.12 Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150 Angle [°] 112 150 199 150 144 144 129 264 197 89 104 304 Detector AV PK PK AV PK AV PK AV PK AV PK AV Verdict PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS END OF REPORT MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 36 of 36Acrobat Distiller 9.3.2 (Windows)