SZ25020263W01 Linkplay AMP003 BLE DTS

Morlab

SZ25020263W01 Linkplay AMP003 BLE DTS

Linkplay Technology Inc. AMP003 WiiM Amp Ultra 2BABF-AMP003 2BABFAMP003 amp003

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=8316418
REPORT No.SZ25020263W01
TEST REPORT

APPLICANT

: Linkplay Technology Inc.

PRODUCT NAME : WiiM Amp Ultra

MODEL NAME

: AMP003

BRAND NAME

: WiiM

FCC ID

: 2BABF-AMP003

STANDARD(S)

: 47 CFR Part 15 Subpart C

RECEIPT DATE

: 2025-03-19

TEST DATE

: 2025-04-15 to 2025-05-09

ISSUE DATE

: 2025-05-19

Edited by:

Zeng Xiaoying (Rapporteur)

Approved by: Shen Junsheng (Supervisor)

NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn

Page 1 of 36

REPORT No.SZ25020263W01
DIRECTORY
1. Summary of Test Result 3 1.1. Testing Applied Standards 4 1.2. Test Equipment List 5 1.3. Measurement Uncertainty 7 1.4. Testing Laboratory7 2. General Description 8 2.1. Information of Applicant and Manufacturer 8 2.2. Information of EUT8 2.3. Channel List of EUT 9 2.4. Test Configuration of EUT 10 2.5. Test Conditions  10 2.6. Test Setup Layout Diagram  10 3. Test Results  13 3.1. Conducted Emission  13 3.2. Restricted Frequency Bands  14 3.3. Radiated Emission  15 Annex A Test Data and Result  17

Version 1.0

Change History Date 2025-05-19

Reason for change First edition

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 2 of 36

1. Summary of Test Result

REPORT No.SZ25020263W01

No. Section Description

Test Date

Test Engineer

Result

Method Determination
/Remark

1 15.203

Antenna Requirement

N/A

N/A

N/ANote1

N/A

2 N/A

Duty Cycle of Test Signal

N/A

N/A

N/ANote1

N/A

Maximum Peak

3 15.247(b) Conducted

N/A

Output Power

N/A

N/ANote1

N/A

Maximum

4

15.247(b)

Average Conducted

N/A

N/A

N/ANote1

N/A

Output Power

5 15.247(a) Bandwidth

N/A

N/A

N/ANote1

N/A

Conducted

6

15.247(d)

Spurious Emission and

N/A

N/A

N/ANote1

N/A

Band Edge

7

15.247(e)

Power Spectral Density

N/A

N/A

N/ANote1

N/A

8 15.207

Conducted Emission

May 09, 2025

Fan Shengquan

PASS

No deviation

Restricted

9 15.247(d) Frequency

Apr. 09, 2025 Gao Jianrou PASS No deviation

Bands

10

15.209, 15.247(d)

Radiated Emission

Apr. 23, 2025 Gao Jianrou PASS No deviation

Note 1: The test results of all conducted test items please refer to the module FCC

test report (Report No.: SZ24040154W01), which issued on Jul. 26, 2024.

Note 2: The tests were performed according to the method of measurements prescribed in ANSI

C63.10-2013 and KDB 558074 D01 v05r02.

Note 3: Additions to, deviation, or exclusions from the method shall be judged in the "method

determination" column of add, deviate or exclude from the specific method shall be explained in the

"Remark" of the above table.

Note 4: When the test result is a critical value, we will use the measurement uncertainty give the

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 3 of 36

REPORT No.SZ25020263W01
judgment result based on the 95% confidence intervals.
1.1. Testing Applied Standards
According to the specifications of the manufacturer, the EUT must comply with the requirements of the following standards:  47 CFR Part 15 Subpart C Radio Frequency Devices

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 4 of 36

1.2. Test Equipment List

REPORT No.SZ25020263W01

1.2.1 Conducted Emission Test Equipment

Equipment

Serial No.

Type

Receiver

MY56400093 N9038A

LISN

8127449

Pulse Limiter (10dB)
RF Coaxial Cable (DC-100MHz)

VTSD 9561 FB #206
BNC

NSLK 8127 VTSD 9561-F
MRE04

Manufacturer KEYSIGHT

Cal. Date Due Date 2025.01.06 2026.01.05

Schwarzbeck 2025.01.09 2026.01.08

Schwarzbeck 2024.05.30 2025.05.29

Qualwave

2024.07.02 2025.07.01

1.2.2 List of Software Used Description JS32-RE
TS+ -[JS32-CE]

Manufacturer Tonscend Tonscend

Software Version 5.0.0 2.5.0.0

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 5 of 36

REPORT No.SZ25020263W01

1.2.4 Radiated Test Equipment

Equipment

Serial No.

Signal Analyzer MY56060145

Test Antenna - BiLog

9163-519

Test Antenna Loop

1519-022

Test Antenna ­ Horn

01774

Test Antenna ­ BBHA9170

Horn

#773

Preamplifier (10MHz-6GHz)

46732

Preamplifier (2GHz-18GHz)

61171/61172

Preamplifier (18GHz-40GHz)

DS77209

Type N9020A VULB 9163
FMZB1519
BBHA 9120D
BBHA9170 S10M100L38
02 S020180L32
03 DCLNA0118-
40C-S

RF Coaxial Cable (DC-18GHz)

MRE001

PE330

RF Coaxial Cable (DC-18GHz)
RF Coaxial Cable (DC-18GHz)
RF Coaxial Cable (DC-40GHz)
RF Coaxial Cable (DC-40GHz)
RF Coaxial Cable (DC-18GHz)
Notch Filter
Anechoic Chamber Anechoic Chamber

MRE002 MRE003 22290045 22290046 22120181
N/A N/A N/A

CLU18
CLU18
QA360-40KK-0.5
QA360-40KKF-2
QA500-18NN-5
WRCG-24002483.5-60SS
9m*6m*6m
9m*6m*6m

Manufacturer Agilent
Schwarzbeck Schwarzbeck Schwarzbeck Schwarzbeck LUCIX CORP. LUCIX CORP.
Decentest
Pasternack
Pasternack Pasternack Qualwave Qualwave Qualwave Wainwright
CRT CRT

Cal. Date 2024.05.30 2024.06.22 2024.06.03 2024.06.22 2024.06.22 2024.05.30 2024.05.30 2024.05.30
2024.05.30
2024.05.30 2024.05.30 2024.07.03 2024.07.03 2024.07.03
N/A 2025.04.19 2022.11.30

Due Date 2025.05.29 2025.06.21 2025.06.02 2025.06.21 2025.06.21 2025.05.29 2025.05.29 2025.05.29
2025.05.29
2025.05.29 2025.05.29 2025.07.02 2025.07.02 2025.07.02
N/A 2028.04.18 2025.11.29

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 6 of 36

1.3. Measurement Uncertainty

REPORT No.SZ25020263W01

Test Items Restricted Frequency Bands Radiated Emission Conducted Emission
1.4. Testing Laboratory

Uncertainty ±5% ±2.95dB ±2.44dB

Remark Confidence levels of 95% Confidence levels of 95% Confidence levels of 95%

Laboratory Name
Laboratory Address
Telephone Facsimile FCC Designation Number FCC Test Firm Registration Number

Shenzhen Morlab Communications Technology Co., Ltd. FL.3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China +86 755 36698555 +86 755 36698525 CN1192
226174

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 7 of 36

2. General Description

REPORT No.SZ25020263W01

2.1. Information of Applicant and Manufacturer

Applicant Applicant Address Manufacturer Manufacturer Address

Linkplay Technology Inc. 8000 Jarvis Avenue Suite #130, Newark, CA 94560 Linkplay Technology Inc. 8000 Jarvis Avenue Suite #130, Newark, CA 94560

2.2. Information of EUT

Product Name:

WiiM Amp Ultra

Sample No.:

4#, 25#

Hardware Version:

A98D V02+Main Board V02

Software Version:

Linkplay.5.2.708867

Equipment Type:

Bluetooth LE

Bluetooth Version:

5.3

Modulation Type:

GFSK

Data Rate:

1Mbps, 2Mbps

Operating Frequency Range: 2402MHz-2480MHz

Antenna Type:

PIFA Antenna

Antenna Gain:

ANT1: 3.46dBi; ANT2: 3.46dBi

Note 1: The test results of all conducted test items please refer to the module FCC test report

(Report No.: SZ24040154W01), which issued on Jul. 26, 2024. We only recorded the radiated test

result in this report.

Note 2: The EUT has two antennas and it operates in single antenna. Both of the two antennas

were evaluated separately, only the worst test result (ANT2) were recorded in the test report.

Note 3: For a more detailed description, please refer to Specification or User's Manual supplied by the applicant and/or manufacturer.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 8 of 36

2.3. Channel List of EUT

REPORT No.SZ25020263W01

Channel

Frequency (MHz)

Channel

Frequency (MHz)

Channel

Frequency (MHz)

Channel

Frequency (MHz)

0

2402

10

2422

20

2442

30

2462

1

2404

11

2424

21

2444

31

2464

2

2406

12

2426

22

2446

32

2466

3

2408

13

2428

23

2448

33

2468

4

2410

14

2430

24

2450

34

2470

5

2412

15

2432

25

2452

35

2472

6

2414

16

2434

26

2454

36

2474

7

2416

17

2436

27

2456

37

2476

8

2418

18

2438

28

2458

38

2478

9

2420

19

2440

29

2460

39

2480

Note 1: The black bold channels were selected for test.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 9 of 36

2.4. Test Configuration of EUT

REPORT No.SZ25020263W01

Test mode is used to control the EUT under the maximum power level during test.
2.5. Test Conditions

Temperature (°C) Relative Humidity (%) Atmospheric Pressure (kPa)

15-35 30-60 86-106

2.6. Test Setup Layout Diagram

2.6.1.Conducted Emission Measurement

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 10 of 36

2.6.2.Radiation Measurement 1) For radiated emissions from 9kHz to 30MHz

REPORT No.SZ25020263W01

2) For radiated emissions from 30MHz to1GHz

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 11 of 36

3) For radiated emissions above 1GHz

REPORT No.SZ25020263W01

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 12 of 36

3. Test Results

REPORT No.SZ25020263W01

3.1. Conducted Emission

3.1.1.Requirement

According to FCC section 15.207, for an intentional radiator that is designed to be connected to the

public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power

line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in the following

table, as measured using a 50µH/50 line impedance stabilization network (LISN).

Frequency Range (MHz)

Conducted Limit (dBµV)

Quai-peak

Average

0.15 - 0.50

66 to 56

56 to 46

0.50 - 5

56

46

5 - 30

60

50

Note:

(a) The lower limit shall apply at the band edges.

(b) The limit decreases linearly with the logarithm of the frequency in the range 0.15 - 0.50MHz.

3.1.2.Test Procedures

The Table-top EUT was placed upon a non-metallic table 0.8m above the horizontal metal reference ground plane. EUT was connected to LISN and LISN was connected to reference Ground Plane. EUT was 80cm from LISN. The set-up and test methods were according to ANSI C63.10: 2013.

3.1.3.Test Setup Layout Refer to chapter 2.6.2 in this report.

3.1.4.Test Result Refer to Annex A.1 in this report.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 13 of 36

3.2. Restricted Frequency Bands

REPORT No.SZ25020263W01

3.2.1.Requirement
According to FCC section 15.247(d), in any 100kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20dB below that in the 100kHz bandwidth within the band that contains the highest level of the desired power, In addition, radiated emissions which fall in the restricted bands, as defined in 15.205(a), must also comply with the radiated emission limits specified in 15.209(a).

3.2.2.Test Procedures
The EUT is located in a 3m Semi-Anechoic Chamber; the antenna factors, cable loss and so on of the site as factors are calculated to correct the reading. For the Test Antenna: Test Antenna is 3m away from the EUT. Test Antenna height is varied from 1m to 4m above the ground to determine the maximum value of the field strength. Span = wide enough to fully capture the emission being measured RBW = 1 MHz for f  1GHz, 100 kHz for f < 1GHz VBW = 3 MHz Sweep = auto Detector function = peak/average Trace = max hold Allow the trace to stabilize

3.2.3.Test Setup Layout Refer to chapter 2.6.3 in this report.

3.2.4.Test Result Refer to Annex A.2 in this report.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 14 of 36

3.3. Radiated Emission

REPORT No.SZ25020263W01

3.3.1.Requirement

According to FCC section 15.247(d), radiated emission outside the frequency band attenuation below the general limits specified in FCC section 15.209(a) is not required. In addition, radiated emissions which fall in the restricted bands, as defined in FCC section 15.205(a), must also comply with the radiated emission limits specified in FCC section 15.209(a).

According to FCC section 15.209 (a), except as provided elsewhere in this subpart, the emissions

from an intentional radiator shall not exceed the field strength levels specified in the following

table:

Frequency (MHz)

Field Strength (µV/m)

Measurement Distance (m)

0.009 - 0.490

2400/F(kHz)

300

0.490 - 1.705

24000/F(kHz)

30

1.705 - 30.0

30

30

30 - 88

100

3

88 - 216

150

3

216 - 960

200

3

Above 960

500

3

Note1: For above 1000MHz, the emission limit in this paragraph is based on measurement

instrumentation employing an average detector, measurement using instrumentation with a peak

detector function, corresponding to 20dB above the maximum permitted average limit.

Note2:For above 1000MHz, limit field strength of harmonics: 54dBuV/m@3m (AV) and

74dBuV/m@3m (PK).In addition, radiated emissions which fall in the restricted bands, as defined

in Section 15.205(a), also should comply with the radiated emission limits specified in Section

15.209(a)(above table).

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 15 of 36

REPORT No.SZ25020263W01
3.3.2.Test Procedures
The EUT is placed on a non-conducting table 80 cm above the ground plane for measurement below 1GHz; 1.5 m above the ground plane for measurement above 1GHz.The antenna to EUT distance is 3meters. The EUT is configured in accordance with ANSI C63.10. The EUT is set to transmit in a continuous mode.
For measurements below 30MHz, the emission limits shown in the above table are based on measurements employing a CISPR quasi-peak detector except for the frequency bands 9kHz-90 kHz, 110kHz-490 kHz. Radiated emission limits in these two bands are based on measurements employing an average detector.
For measurements below 1GHz the resolution bandwidth is set to 100kHz for peak detection measurements or 120kHz for quasi-peak detection measurements. Peak detection is used unless otherwise noted as quasi-peak.
For measurements above 1GHz the resolution bandwidth is set to 1MHz, the video band width is set to 3MHz for peak measurements and as applicable for average measurements.
The EUT is rotated through 360 degrees to maximize emissions received. The antenna is scanned from 1 to 4 meters above the ground plane to further maximize the emission. Measurements are made with the antenna polarized in both the vertical and the horizontal positions. For measurements above 1 GHz, keeping the measurement antenna aimed at the source of emissions at each frequency of significant emissions, with polarization oriented for maximum response.
3.3.3.Test Setup Layout
Refer to chapter 2.6.3 in this report.
3.3.4.Test Result
Refer to Annex A.3 in this report.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 16 of 36

REPORT No.SZ25020263W01
Annex A Test Data and Result
A.1. Conducted Emission
The maximum conducted interference is searched using Peak (PK), if the emission levels more than the AV and QP limits, and that have narrow margins from the AV and QP limits will be remeasured with AV and QP detectors. Tests for both L phase and N phase lines of the power mains connected to the EUT are performed. Set RBW=9kHz, VBW=30kHz. Refer to recorded points and plots below. Note: Both of the test voltage AC 120V/60Hz and AC 230V/50Hz were considered and tested respectively, only the results of the worst case AC 120V/60Hz were recorded in this report. A. Test Setup: Test Mode: EUT+TV+HDMl cable+Load+Fiber box+Mobile phone+Audio+U disk+BT TX Test voltage: AC 120V/60Hz The measurement results are obtained as below: E [dBV] =UR + LCable loss [dB] + AFactor UR: Receiver Reading AFactor: Voltage division factor of LISN

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 17 of 36

B. Test Plot:

REPORT No.SZ25020263W01

(L Phase)

No.

Fre. (MHz)

Emission Level (dBµV) Quai-peak Average

1 0.1590

48.77

29.17

2 0.2895

42.55

27.22

3 0.4200

43.55

26.46

4 0.5640

33.71

22.21

5 0.6989

32.44

21.50

6 9.7297

27.73

17.75

Limit (dBµV)

Quai-peak 65.52 60.54 57.45 56.00 56.00 60.00

Average 55.52 50.54 47.45 46.00 46.00 50.00

Power-line Verdict

PASS

PASS

Line

PASS PASS

PASS

PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 18 of 36

REPORT No.SZ25020263W01

(N Phase)

No.

Fre. (MHz)

Emission Level (dBµV) Quai-peak Average

1 0.2445

39.42

25.47

2 0.2580

39.95

25.81

3 0.3975

44.86

26.59

4 0.5370

31.97

21.37

5 7.4540

29.87

15.18

6 18.2432 40.50

37.11

Limit (dBµV)

Quai-peak 61.94 61.49 57.91 56.00 60.00 60.00

Average 51.94 51.49 47.91 46.00 50.00 50.00

Power-line Verdict

Neutral

PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 19 of 36

REPORT No.SZ25020263W01
A.2. Restricted Frequency Bands
Note: Restricted Frequency Bands were performed when antenna was at vertical and horizontal polarity, and only the worse test condition (Vertical) was recorded in this test report. 1Mbps Plot for Channel 0

Fre. (MHz) 2324.11 2333.52 2351.84 2355.25 2374.36 2375.17

Reading [dBV]
12.9 -0.3 12.0 -0.2 13.5 0.5

Level [dBV/m]
45.01 31.99 44.44 32.18 45.96 33.00

Factor [dB/m] 32.150 32.240 32.400 32.420 32.490 32.490

Limit [dBV/m]
74.00 54.00 74.00 54.00 74.00 54.00

Margin [dB] 28.99 22.01 29.56 21.82 28.04 21.00

Height [cm] 150 150 150 150 150 150

Angle [°] 352 224 360 185 224 312

Detector
PK AV PK AV PK AV

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 20 of 36

Plot for Channel 39

REPORT No.SZ25020263W01

Fre. (MHz) 2483.50 2484.48 2489.69 2489.77 2494.63 2494.68

Reading [dBV]
7.0 18.3 5.5 17.8 17.7 5.4

Level [dBV/m]
39.98 51.33 38.49 50.82 50.66 38.37

Factor [dB/m] 33.030 33.030 33.020 33.020 33.010 33.010

Limit [dBV/m]
54.00 74.00 54.00 74.00 74.00 54.00

Margin [dB] 14.02 22.67 15.51 23.18 23.34 15.63

Height [cm] 150 150 150 150 150 150

Angle [°] 195 175 308 53 206 1

Detector
AV PK AV PK PK AV

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 21 of 36

2Mbps Plot for Channel 0

REPORT No.SZ25020263W01

Fre. (MHz) 2332.22 2338.93 2368.76 2375.07 2376.37 2387.68

Reading [dBV]
12.5 -0.2 -0.4 0.5 12.5 12.1

Level [dBV/m]
44.71 32.09 32.12 32.95 44.99 44.65

Factor [dB/m] 32.230 32.290 32.470 32.490 32.490 32.540

Limit [dBV/m]
74.00 54.00 54.00 54.00 74.00 74.00

Margin [dB] 29.29 21.91 21.88 21.05 29.01 29.35

Height [cm] 150 150 150 150 150 150

Angle [°] 203 349 242 232 194 0

Detector
PK AV AV AV PK PK

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 22 of 36

Plot for Channel 39

REPORT No.SZ25020263W01

Fre. (MHz) 2483.95 2484.04 2486.42 2487.87 2488.76 2493.36

Reading [dBV]
17.4 5.7 19.8 18.4 5.7 5.6

Level [dBV/m]
50.40 38.76 52.84 51.46 38.71 38.63

Factor [dB/m] 33.030 33.030 33.030 33.020 33.020 33.010

Limit [dBV/m]
74.00 54.00 74.00 74.00 54.00 54.00

Margin [dB] 23.60 15.24 21.16 22.54 15.29 15.37

Height [cm] 150 150 150 150 150 150

Angle [°] 183 225 173 195 22 11

Detector
PK AV PK PK AV AV

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 23 of 36

REPORT No.SZ25020263W01
A.3. Radiated Emission
According to ANSI C63.10, because of peak detection will yield amplitudes equal to or greater than amplitudes measured with the quasi-peak (or average) detector, the measurement data from a spectrum analyzer peak detector will represent the worst-case results, if the peak measured value complies with the quasi-peak (or average) limit, it is unnecessary to perform an quasi-peak measurement (or average).
The measurement results are obtained as below: E [dBV/m] =UR + AT + AFactor [dB]; AT =LCable loss [dB]-Gpreamp [dB] AT: Total correction Factor except Antenna UR: Receiver Reading Gpreamp: Preamplifier Gain AFactor: Antenna Factor at 3m During the test, the total correction Factor AT and AFactor were built in test software. Note1: All radiated emission tests were performed in X, Y, Z axis direction. And only the worst axis test condition was recorded in this test report. Note2: For the frequency, which started from 9kHz to 30MHz, was pre-scanned and the result which was 20dB lower than the limit was not recorded. Note3: For the frequency, which started from 18GHz to 10th harmonic of the highest frequency, was pre-scanned and the result which was 20dB lower than the limit was not recorded. Note 4: All test modes were considered and evaluated respectively by performing full test, only the worst data were recorded.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 24 of 36

1Mbps Plot for Channel 0

REPORT No.SZ25020263W01

Fre. (MHz) 55.85 104.74 163.92 250.01 531.13 798.42

(Antenna Horizontal, 30MHz to 1GHz)

Reading [dBV]
62.0 67.6 66.9 66.6 53.6 42.2

Level [dBV/m]
33.98 38.29 35.87 39.11 34.62 27.65

Factor [dB/m] -28.010 -29.300 -31.050 -27.490 -18.930 -14.570

Limit [dBV/m]
40.00 43.50 43.50 46.00 46.00 46.00

Margin [dB] 6.02 5.21 7.63 6.89 11.38 18.35

Height [cm] 150 150 150 150 150 150

Angle [°] 334 341 178 359 164 348

Detector
PK PK PK PK PK PK

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 25 of 36

REPORT No.SZ25020263W01

(Antenna Horizontal, 1GHz to 18GHz)

Fre. (MHz) 1061.21 1061.61 2472.69 2473.89 3202.72 3203.15 5669.22 5706.08 10615.07 10713.65 14477.47 14672.48

Reading [dBV]
37.0 49.0 28.5 40.4 54.6 51.5 36.5 46.0 31.4 40.5 36.5 26.8

Level [dBV/m]
34.36 46.33 34.36 46.26 43.67 40.58 35.37 45.25 43.59 52.80 56.06 47.37

Factor [dB/m] -2.660 -2.640 5.910 5.900 -10.880 -10.880 -1.100 -0.760 12.150 12.330 19.550 20.530

Limit [dBV/m]
54.00 74.00 54.00 74.00 74.00 54.00 54.00 74.00 54.00 74.00 74.00 54.00

Margin [dB] 19.64 27.67 19.64 27.74 30.33 13.42 18.63 28.75 10.41 21.20 17.94 6.63

Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150

Angle [°] 1 1 193 90 158 158 319 158 185 130 76 9

Detector
AV PK AV PK PK AV AV PK AV PK PK AV

Verdict
PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 26 of 36

REPORT No.SZ25020263W01

Fre. (MHz) 30.58 52.99 104.74 163.96 532.53 749.97

(Antenna Vertical, 30MHz to 1GHz)

Reading [dBV]
67.3 61.8 62.8 62.2 54.4 51.2

Level [dBV/m]
36.56 34.06 33.50 31.12 35.42 36.38

Factor [dB/m] -30.750 -27.770 -29.300 -31.040 -18.990 -14.840

Limit [dBV/m]
40.00 40.00 43.50 43.50 46.00 46.00

Margin [dB] 3.44 5.94 10.00 12.38 10.58 9.62

Height [cm] 150 150 150 150 150 150

Angle [°] 241 347 130 72 220 340

Detector
PK PK PK PK PK PK

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 27 of 36

REPORT No.SZ25020263W01

(Antenna Vertical, 1GHz to 18GHz)

Fre. (MHz) 1119.22 1127.23 2402.28 2418.68 3202.72 3203.15 5219.63 5220.92 7992.57 7996.86 14684.05 14738.48

Reading [dBV]
33.1 44.5 30.6 39.7 60.0 57.2 49.4 41.8 35.1 44.7 26.6 37.1

Level [dBV/m]
30.87 42.33 35.89 45.20 49.09 46.34 46.04 38.51 40.19 49.78 47.19 57.33

Factor [dB/m] -2.190 -2.140 5.250 5.500 -10.880 -10.880 -3.330 -3.310 5.050 5.120 20.560 20.270

Limit [dBV/m]
54.00 74.00 54.00 74.00 74.00 54.00 74.00 54.00 54.00 74.00 54.00 74.00

Margin [dB] 23.13 31.67 18.11 28.80 24.91 7.66 27.96 15.49 13.81 24.22 6.81 16.67

Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150

Angle [°] 137 132 148 170 76 64 130 130 64 64 117 330

Detector
AV PK AV PK PK AV PK AV AV PK AV PK

Verdict
PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 28 of 36

Plot for Channel 19

REPORT No.SZ25020263W01

Fre. (MHz) 55.90 104.74 163.96 331.78 531.95 749.97

(Antenna Horizontal, 30MHz to 1GHz)

Reading [dBV]
62.3 67.6 66.8 58.5 55.9 50.6

Level [dBV/m]
34.30 38.34 35.79 34.15 36.97 35.74

Factor [dB/m] -28.020 -29.300 -31.040 -24.390 -18.970 -14.840

Limit [dBV/m]
40.00 43.50 43.50 46.00 46.00 46.00

Margin [dB] 5.70 5.16 7.71 11.85 9.03 10.26

Height [cm] 150 150 150 150 150 150

Angle [°] 0 295 209 40 174 281

Detector
PK PK PK PK PK PK

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 29 of 36

REPORT No.SZ25020263W01

(Antenna Horizontal, 1GHz to 18GHz)

Fre. (MHz) 1040.01 1114.42 2440.29 2473.49 3253.29 3253.72 5213.21 5214.49 11093.80 11125.52 14690.05 14691.76

Reading [dBV]
36.5 46.8 33.6 39.5 53.1 50.4 47.8 40.6 30.2 40.0 26.9 35.5

Level [dBV/m]
33.69 44.57 39.46 45.45 41.76 39.04 44.40 37.18 44.22 53.96 47.48 56.12

Factor [dB/m] -2.820 -2.230 5.820 5.910 -11.310 -11.310 -3.440 -3.420 14.000 13.920 20.570 20.580

Limit [dBV/m]
54.00 74.00
74.00 74.00 54.00 74.00 54.00 54.00 74.00 54.00 74.00

Margin [dB] 20.31 29.43 28.55 32.24 14.96 29.60 16.82 9.78 20.04 6.52 17.88

Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150

Angle [°] 1 160 132 241 250 250 24 24 184 116 9 24

Detector
AV PK AV PK PK AV PK AV AV PK AV PK

Verdict
PASS PASS
NA PASS PASS PASS PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 30 of 36

REPORT No.SZ25020263W01

Fre. (MHz) 30.63 52.60 101.88 164.50 331.78 531.03

(Antenna Vertical, 30MHz to 1GHz)

Reading [dBV]
65.8 61.9 63.3 63.2 55.5 49.5

Level [dBV/m]
35.06 34.09 33.66 31.97 31.15 30.61

Factor [dB/m] -30.750 -27.850 -29.600 -31.220 -24.390 -18.930

Limit [dBV/m]
40.00 40.00 43.50 43.50 46.00 46.00

Margin [dB] 4.94 5.91 9.84 11.53 14.85 15.39

Height [cm] 150 150 150 150 150 150

Angle [°] 210 288 118 32 309 210

Detector
PK PK PK PK PK PK

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 31 of 36

REPORT No.SZ25020263W01

(Antenna Vertical, 1GHz to 18GHz)

Fre. (MHz) 1063.61 1063.61 2439.89 2440.29 3253.29 3253.72 6361.81 6364.81 11108.37 11110.52 14703.33 14711.91

Reading [dBV]
46.6 36.2 43.0 40.0 56.9 55.4 48.2 39.1 40.4 30.0 26.6 35.8

Level [dBV/m]
43.96 33.53 48.81 45.84 45.63 44.10 49.38 40.25 54.47 44.00 47.15 56.27

Factor [dB/m] -2.640 -2.640 5.820 5.820 -11.310 -11.310 1.160 1.140 14.030 14.020 20.570 20.500

Limit [dBV/m]
74.00 54.00
74.00 54.00 74.00 54.00 74.00 54.00 54.00 74.00

Margin [dB] 30.04 20.47 28.37 9.90 24.62 13.75 19.53 10.00 6.85 17.73

Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150

Angle [°] 55 55 142 142 64 144 157 144 170 264 345 184

Detector
PK AV PK AV PK AV PK AV PK AV AV PK

Verdict
PASS PASS
NA NA PASS PASS PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 32 of 36

Plot for Channel 39

REPORT No.SZ25020263W01

Fre. (MHz) 56.00 104.74 164.50 250.01 533.16 916.67

(Antenna Horizontal, 30MHz to 1GHz)

Reading [dBV]
62.1 66.9 69.1 68.2 55.6 41.4

Level [dBV/m]
34.09 37.57 37.86 40.75 36.60 29.42

Factor [dB/m] -28.050 -29.300 -31.220 -27.490 -19.020 -11.930

Limit [dBV/m]
40.00 43.50 43.50 46.00 46.00 46.00

Margin [dB] 5.91 5.93 5.64 5.25 9.40 16.58

Height [cm] 150 150 150 150 150 150

Angle [°] 359 334 207 359 137 87

Detector
PK PK PK PK PK PK

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 33 of 36

REPORT No.SZ25020263W01

(Antenna Horizontal, 1GHz to 18GHz)

Fre. (MHz) 1053.61 1054.01 2413.48 2471.49 3306.44 3307.29 5219.63 5222.21 7579.85 7591.85 14538.76 14685.76

Reading [dBV]
47.5 35.2 40.7 28.3 50.9 46.8 48.8 41.6 44.8 34.7 36.9 26.5

Level [dBV/m]
44.78 32.45 46.09 34.19 39.86 35.78 45.51 38.34 49.54 39.55 56.87 47.05

Factor [dB/m] -2.720 -2.700 5.420 5.910 -11.000 -10.990 -3.330 -3.290 4.750 4.860 20.010 20.560

Limit [dBV/m]
74.00 54.00 74.00 54.00 74.00 54.00 74.00 54.00 74.00 54.00 74.00 54.00

Margin [dB] 29.22 21.55 27.91 19.81 34.14 18.22 28.49 15.66 24.46 14.45 17.13 6.95

Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150

Angle [°] 351 351 324 166 265 265 144 144 184 360 169 9

Detector
PK AV PK AV PK AV PK AV PK AV PK AV

Verdict
PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 34 of 36

REPORT No.SZ25020263W01

Fre. (MHz) 30.63 62.55 184.33 282.60 533.16 750.02

(Antenna Vertical, 30MHz to 1GHz)

Reading [dBV]
65.8 63.3 63.0 60.7 51.4 45.4

Level [dBV/m]
35.01 34.48 32.90 34.43 32.35 30.52

Factor [dB/m] -30.750 -28.790 -30.090 -26.310 -19.020 -14.840

Limit [dBV/m]
40.00 40.00 43.50 46.00 46.00 46.00

Margin [dB] 4.99 5.52 10.60 11.57 13.65 15.48

Height [cm] 150 150 150 150 150 150

Angle [°] 159 68 245 273 173 102

Detector
PK PK PK PK PK PK

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 35 of 36

REPORT No.SZ25020263W01

(Antenna Vertical, 1GHz to 18GHz)

Fre. (MHz) 1183.24 1266.05 2464.69 2480.30 3306.87 3307.29 7089.55 7201.41 10534.93 11098.95 14470.61 14706.33

Reading [dBV]
31.5 43.3 39.4 31.6 53.7 49.2 44.8 34.4 40.8 30.1 36.8 26.3

Level [dBV/m]
30.13 41.95 45.33 37.48 42.66 38.16 48.93 39.50 52.85 44.14 56.24 46.88

Factor [dB/m] -1.380 -1.300 5.930 5.890 -11.000 -10.990 4.140 5.100 12.030 14.060 19.470 20.540

Limit [dBV/m]
54.00 74.00 74.00 54.00 74.00 54.00 74.00 54.00 74.00 54.00 74.00 54.00

Margin [dB] 23.87 32.05 28.67 16.52 31.34 15.84 25.07 14.50 21.15 9.86 17.76 7.12

Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150

Angle [°] 112 150 199 150 144 144 129 264 197 89 104 304

Detector
AV PK PK AV PK AV PK AV PK AV PK AV

Verdict
PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS

END OF REPORT

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 36 of 36


Acrobat Distiller 9.3.2 (Windows)