Instructions for DELTA models including: DVP-F232 PLC Extension Card, DVP-F232, PLC Extension Card, Extension Card, Card
21 mag 2024 — EH2 MPU built in COM1 (RS-232) and COM2 (RS-485). When connecting. RS-232 to PC or other peripheral, such as MODEM, by using COM2, you.
%PDF-1.4 %âãÏÓ 195 0 obj > endobj xref 195 20 0000000016 00000 n 0000002019 00000 n 0000002104 00000 n 0000002301 00000 n 0000002401 00000 n 0000002884 00000 n 0000002987 00000 n 0000003257 00000 n 0000005613 00000 n 0000008093 00000 n 0000010417 00000 n 0000012722 00000 n 0000014921 00000 n 0000017249 00000 n 0000017860 00000 n 0000018110 00000 n 0000020422 00000 n 0000022815 00000 n ...
Wiring Please use single or multi-core cables with 14-30 AWG (0.25~1.6 mm). PLC terminal screws should be tightened to 9.50 kg-cm (8.25 in-Ibs) and please use only 60/75ºC copper conductor.
File Info : application/pdf, 19 Pages, 1.86MB
DocumentDocumentDVP-0407730-02 20240521 Warning ENGLISH This instruction provides electrical specifications, functional specifications, wiring and basic program design. For detailed program design and explanation of instructions, please refer to DVP-PLC Application Manual (programming). This is an OPEN-TYPE function extension card. When installing it, you should turn off the MPU and have static electricity protection (such as wearing antistatic gloves) to prevent those components on the function extension card from being damaged by static. This instruction is for DVP series function extension cards. Please find out the model you order in the following for correct usage. Introduction Thank you for choosing Delta's PLC extension card of DVP-EH Series. There are analog input/output card (AI/AO), digital input/output card (DI/DO), extension card for communication port and memory card. Refer to following table for detail. Model Name Outline Function Explanation DVP-F232 (RS-232 card) EH2 MPU built in COM1 (RS-232) and COM2 (RS-485). When connecting RS-232 to PC or other peripheral, such as MODEM, by using COM2, you can use this extension card. The communication function is the same as Terminal Layout (DB-9 COM2 except communication interface, i.e. there are Slave mode and male) Master mode for you to choose. Note: PLC will set that COM2 is occupied by RS-232 card and built-in COM2 (RS-485) function will be invalid after G ND V. High Tx Rx 5 4 3 2 1 9 inserting this card. Refer to following for system connection. 8 7 6 V. High PC RS-485 is invalid V. High: high potential, i.e. logic 1 Note: Please pay attention for pin 2 and pin 3 when or (R S-2 3 2) e xte ns io n c a rd for DVP EH MP U co mmun ica tion po rt DVP-F232 or DVP-F422 s e le ct o n e Master/Slave d e vic e HMI connecting this communication port to PC or HMI. MODEM PC HMI For EH3 MPU, it will be COM3 card and either slave or master mode can be used. Application example for connection in Slave mode PLC COM2 /COM3 PC RS-232 s e r ia l po rt 3 Tx Tx 3 2 Rx Rx 2 7 7 8 8 6 6 5 GND S.G.5 1 1 4 4 9 Rl. 9 DB-9 FEMALE DB-9 FEMALE PLC COM2/ De lt a HMI COM3 DOPA series 3 Tx Tx 3 2 Rx Rx 2 7 7 8 8 6 6 5 GND S.G.5 1 1 4 4 9 9 DB-9 FEMALE DB-9 MA LE PLC COM2/ COM 3 HITECH HMI 3 Tx Tx 2 2 Rx Rx 3 7 6 8 8 6 20 5 GND S. G.7 1 4 4 5 9 DB-9 FEMALE DB-25 MALE Model Name Outline DVP-F422 (RS-422 card) Terminal Layout Tx+: transmission Tx+ TxRx+ Rx- GND (+) Tx-: transmission (-) Rx+: receive (+) Rx-: receive (-) Function Explanation For EH2 series: User can use COM2 to connect RS-422 and HMI or other peripheral for long distance connection. The communication function is the same as COM2 except communication interface. Note: PLC will set that COM2 is occupied by RS-422 card and built-in COM2 (RS-485) function will be invalid after inserting this card. Refer to following for system connection. Wiring example PLC COM2 1 Tx+ 2 Tx3 Rx+ 4 Rx- DVP-F422 De lta HMI DOPA s e r ie s Rx+ 2 Rx- 1 6 RTS7 RTS+ De lta HMI DOPA s e rie s : RS-422 is at COM2, and need to set to MODE 2, R e fe r to fo llo win g for s e ttin g : Tx+ 3 8 CTS+ Tx- 4 9 CTS- MODE 1: RS-232 MODE 2: RS-422 COM2/DB-9 MODE 3: RS-485 For EH3 MPU, it will be COM3 card and either slave or master mode can be used. DVP-F2AD There are 2 analog input points supported by F2AD card and their characteristics are shown in the following: Terminal layout 0~10V V0+ I0+ 0~10V V1+ I1+ Voltage input COM CH0 CH1 Item Analog signal Resolution (12bit) Input impedance Update time for conversion Voltage input DC 0~+10V 2.5mV (10/4000) 40K Current input DC 0~20mA 10uA (20/2000) 250 D1118 setting (K150, unit: ms) V0+ 0~20mA I0+ V1+ 0~20mA I1+ Current input COM CH0 CH1 Voltage input signal limit: less than 12VDC (Inputting Characteristic curve Digital value output 4000 Digital output 2000 Digital output 0 10V voltage input 0 20m A current input Current value D1056 (CH0) D1057 (CH1) Average value D1110 (CH0) D1111 (CH1) negative voltage is banned) User can get A/D conversion value saved in special D by reading special D Current input signal limit: that corresponds to current value or average value. D1118 setting is every less than 30mA (Inputting update time of current value of digital value output. negative current is banned) DVP-256FM/ DVP-512FM DVP-256FM(for EH2 series)/DVP-512FM(for EH3 series) is a data backup memory card. There is a switch on it and PLC will check the state of this switch when PLC is power on. If this switch is Off, memory card will be invalid. And it is invalid to change the switch when PLC is power on. All memory data read/write action will be valid when switch is On. NOTE: DVP-512FM is black cover and DVP-256FM is white cover. DVP-F2DA There are 2 analog output points supported by F2DA card and their characteristics are shown in the following: Model Name Outline Function Explanation Terminal layout CH0 V0+ I0+ 0~+10V CH1 V1+ I1+ 0~+10V COM Voltage output Load Impedance: Output voltage 1K Output current 500 Item Analog signal Output impedance Resolution (12bit) Update time for conversion Digital value input Voltage output Current output DC 0~+10V DC 0~20mA 0.5 1M 2.5mV (10/4000) 5uA (20/4000) D1118 setting (K5, unit: ms) D1116 (CH0) D1117 (CH1) 10V 20mA CH0 V0+ I0+ 0 ~ 2 0m A Characteristic curve voltage output cur rent out put CH1 V1+ I1+ 0 ~ 2 0m A 0 4000 digital input 0 4000 digital input COM Current output User can move value to D1116 (CH0) or D1117 (CH1) to get correspondent output load: 0~500 output voltage by using instruction MOV. DVP-F232S (RS-232 card) When two built-in COM1 (RS-232) and COM2 (RS-485) are not enough for use, you can add one COM by this card (number is 3 and is called COM3. There are two interfaces, RS-232 and RS-485, for you to use. Its general Terminal Layout (DB-9 function is the same as COM1 but communication baud rate is female) 9600/19200/38400 bps. PLC scan time will be added at least 0.8ms ~ 2ms GND NC Rx Tx NC 5 4 3 2 1 due to COM3. 9 8 7 6 NC NC Usage limit: PC1 and PC2 can't execute ladder diagram monitor function NC simultaneously when COM2 is slave mode and connect to PC1 with NC executing WPLSoft/ISPSoft and COM3 also connects to PC2 with Note: Please pay attention to signal of pin2 and pin3 executing WPLSoft/ISPSoft. But other communication function is normal. COM1 is out of this limit. PC 1 AC drive or Servo HMI when this communication port is connected to PC or HMI. Especial that this definition is different from DVP-F232 card. DVP-F485S (RS-485 card) D+ D- D+: signal (+) D-: signal (-) PC Extension card for COM2 communication port (RS-485) COM1 or (RS -2 32 ) DVP EH MP U COM3 DVP-F232S or DVP-F485S/F485 select one Master device HMI PC 2 Master Model Name DVP-F485 (RS-485 card) (Only for DVP-EH3 series MPUs) DVP-512FM Outline Function Explanation D+ DVP-F485 only supports DVP-EH3 series MPUs. Its communication port can communicate independently without occupying COM2 on a D- MPU. DVP-F485 can function as a slave or a master. After N1 is SG connected to N2, D+ and D- will be connected to the 120 terminal N1 resistor in parallel. N2 D+ Resistor 120 DN1 N2 DVP-512FM(for EH3 series) is a data backup memory card. There is a switch on it and PLC will check the state of this switch when PLC is power on. If this switch is Off, memory card will be invalid. And it is invalid to change the switch when PLC is power on. All memory data read/write action will be valid when switch is On. NOTE: DVP-512FM is black cover Installation and Maintenance Please make sure that PLC is power off and open extension slot cover before installing or removing function card or memory card. The installed position of function card and memory card are shown at the right side. Please attach terminal label shipped with package on correct terminal to avoid error wiring. Function card installation Please put function card into slot vertically and tighten accessory screws into correct position. Remove function card Backup memory card installation (change switch to On or Off by requirement) and removal Installation Removal Check for finishing installation After PLC is power on, connect PLC to WPLSoft/ISPSoft at PC side. In WPLSoft/ISPSoft, select view -> workspace and then select connected model to connect. At this time, WPLSoft/ISPSoft will detect configuration of PLC MPU system and show the result, including categories of function card and state of memory card (On or Off), in working area. Refer to WPLSoft/ISPSoft user manual for detail. Wiring Please use single or multi-core cables with 14-30 AWG (0.25~1.6 mm). PLC terminal screws should be tightened to 9.50 kg-cm (8.25 in-Ibs) and please use only 60/75ºC copper conductor. Application All kinds of function card provided by DVP series solve the problem that happened in PLC application. For example: Usage timing and application requirement solution (correspond to function card model name) There is space limit for installing and need to deal with analog signal. Use DVP-F2AD or DVP-F2DA You need 1~2 analog output points to control AC drive speed. Use DVP-F2DA Small control system and need 1~2 analog input points. Use DVP-F2AD For EH2: You need to connect PLC to PC and HMI and also control AC Use DVP-F232S or drive. DVP-F485S There are many PLCs and need to download program quickly. (copy Use DVP-256FM or PLC) DVP-512FM For EH2: When built-in COM 2 is RS-485, but what you need is RS-232 or RS-422. Use DVP-F232 or DVP-F422 For EH2: When remote control PLC is by MODEM.(NOT for EH3) Use DVP-F232 Following is application for DI/DO card and AI/AO card: DVP-F2AD application: Terminal Layout detector (voltage) detector (current) GND common terminal V0+ I0+ V1+ I1+ COM Program M1000 MOV D1056 D0 M1000 MOV D1110 D1 MOV D1057 D10 MOV D1111 D11 CH0 CH1 Explanation CH0 AD is variable. Current value is D0 and average value is D1. CH1 AD is variable. Current value is D10 and average value is D11. Conversion calculation of CH0 AD: Conversion calculation of CH1 AD: 4,000 1,472 Di gi ta l output 0 ? +10V Analog input Detector (voltage) produces an input 2,000 voltage CH0. If the value D1 reads is K1472, it 1,234 means input voltage is 1472 10V 3.68V Di gi ta l o ut pu t 0 4000 ? 20mA Analog input Detector (current) produces an input current CH1. If the value D11 reads is K1234, it means input current is 1234 20mA 12.34mA 2000 DVP-F2DA application: Terminal layout V0+ C urre n t o utpu t AC d riv e 1 I0+ V1+ Vo lta g e o u tp u t AVI I1+ ACM COM AC d r iv e 2 ACI ACM Program M1000 MOV D0 D1116 CH0 M1000 MOV D1 D1117 CH1 Conversion calculation of CH0 DA: Conversion calculation of CH1 DA: 20mA 1,234 Analog output 0 ? 4,000 Digital input The current is outputted to ACI of AC drive to be speed control. If you need current 12.34mA, you should give D0: 12.34mA 4000 2468 20mA +10V 5.23 Analog o ut pu t 0 ? 4000 Digital input The voltage is outputted to AVI of AC drive to be speed control. If you need voltage 5.23V, you should give D1: 5.23V 4000 2092 10V DVP-PLC (OPEN TYPE) () DVP DVP-EH PLC /(AI/AO)/(DI/DO) DVP-F232 (RS-232 ) (DB-9 ) GND V. High Tx Rx 5 4 3 2 1 9 8 7 6 V. High EH2 COM1(RS-232)COM2(RS-485) COM2 RS-232 PC MODEM COM2 Slave Master COM2(RS-485 )PLC COM2 RS-232 PC RS-485 V. High ,1 PC HMI 2, 3 or (RS -2 3 2) DVP EH DVP-F232 DVP- F422 Ma te rS la ve HMI MOD EM PC HMI EH3 COM3 Slave Master Slave PLC COM2/COM3 PC RS-232 3 Tx 2 Rx Tx 3 Rx 2 7 7 8 8 6 6 5 GND S.G. 5 1 1 4 4 9 Rl. 9 DB-9 FE MALE DB-9 FE MALE PLC COM2/COM3 DOPA 3 Tx 2 Rx Tx 3 Rx 2 7 7 8 8 6 6 5 GND S.G. 5 1 1 4 4 9 9 DB-9 FE MAL E DB-9 MALE PLC COM2/COM3 HITECH 3 Tx 2 Rx Tx 2 Rx 3 7 6 8 8 6 20 5 GND S.G. 7 1 4 4 5 9 DB-9 FE MALE DB-25 MALE DVP-F422 (RS-422 ) Tx+ TxRx+ Rx- GND Tx Tx Rx Rx DVP-F2AD 0~10V 0~10V V0+ I0+ V1+ I1+ COM CH0 CH1 0~20mA 0~20mA V0+ I0+ V1+ I1+ COM CH0 CH1 12VDC () 30mA () EH2 COM2 RS-422 COM2 COM2(RS-485 )PLC COM2 RS-422 COM2 PLC COM2 1 Tx+ 2 Tx3 Rx+ 4 Rx- DVP -F4 22 DOPA Rx+ 2 Rx- 1 Tx+ 3 Tx- 4 6 RTS7 RTS+ 8 CTS+ 9 CTS- COM2 /DB -9 DOPA RS-422 COM2 MODE 2 MODE 1: RS-232 MODE 2: RS-422 MODE 3: RS-485 EH3 COM3 Slave Master F2AD 2 DC 0~+10V DC 0~20mA (12bit) 2.5mV (10/4000) 10uA (20/2000) 40K 250 D1118 (K150, ms) 4000 0 10V 2000 0 20mA D1056(CH0) D1110 (CH0) D1057(CH1) D1111 (CH1) D A/D D1118 DVP-F2DA CH0 V0+ I0+ 0~+10V CH1 V1+ I1+ 0~+10V COM 1K 500 F2DA 2 DC 0~+10V DC 0~20mA 0.5 1M (12bit) 2.5mV (10/4000) 5uA (20/4000) D1118 (K5, ms) D1116 (CH0) D1117 (CH1) 10V 0 4000 2 0mA 0 4000 CH0 V0+ I0+ CH 1 V1+ I1+ COM 0~20mA 0~20mA MOV D1116(CH0) D1117(CH1) 0 ~ 500 DVP-F232S (RS-232 ) (DB-9 ) GND NC Rx Tx NC 5 4 3 2 1 9 8 7 6 NC NC NC NC PC HMI 2, 3 DVP-F232 COM1(RS-232)COM2(RS-485) COM COM( 3 COM3 RS-232 RS-485 COM1 9600/19200/38400 bps COM3 PLC 0.8ms2ms COM2 Slave PC1 WPLSoft/ISPSoft COM3 PC2 WPLSoft/ISPSoft PC1 PC2 COM1 PC 1 HMI PC COM2 (RS-485) DVP-F485S (RS-485 ) D+ D- D D COM1 or (RS-232) DVP EH COM3 DVP-F232S or DVP-F485S/F485 Master HMI PC 2 Master DVP-F485 (RS-485 ) ( EH3 ) D+ DVP-F485 EH3 D- COM2 Slave Master SG N1 N2 D+ D- 120 N1 N2 Resistor D+ 120 DN1 N2 DVP-512FM DVP-512FM(EH3 ) PLC Off PLC ( On) DVP-512FM PLC -- ( On Off) PLC PC WPLSoft/ISPSoft [][][] WPLSoft/ISPSoft PLC () WPLSoft/ISPSoft 14-30 AWG0.25~1.6 mm 5 kg-cm4.34 in-lbs 60/75°C DVP PLC () DVP-F2AD DVP-F2DA 1~2 DVP-F2DA 1~2 DVP-F2AD EH2 PLC PCHMI DVP-F232S DVP-F485S PLC (PLC ) DVP-512FM EH2 COM2 RS-485 RS-232 RS-422 DVP-F232 DVP-F422 EH2 MODEM PLC EH3 DVP-F232 DI/DO AI/AO DVP-F2AD () () GND V0+ I0+ V1+ I1+ COM M1000 M1000 MOV D1056 D0 MOV D1110 D1 MOV D1057 D10 MOV D1111 D11 CH0 AD D0 D1 CH0 CH1 AD D10 D11 CH1 CH0 AD CH1 AD 4,000 1 ,4 72 0 ? +10V () CH0 D1 K1472 1472 10V 3.68V 4000 2,000 1,234 0 ? 20mA () CH1 D11 K1234 1234 20mA 12.34mA 2000 DVP-F2DA V0+ 1 I0+ AVI V1+ I1+ ACM COM 2 ACI ACM M1000 MOV D0 D1116 CH0 M1000 MOV D1 D1117 CH1 CH0 DA CH1 DA 20mA 1,234 ACI 12.34mAD0 20mA 1,234 AVI 5.23V D1 0 ? 4,000 12.34mA 4000 2468 20mA 0 ? 4,000 5.23V 4000 2092 10V PLC [] (OPEN TYPE) () DVP DVP-EH PLC /(AI/AO)/(DI/DO) DVP-F232 (RS-232 ) (DB-9 ) GND V. High Tx Rx 5 4 3 2 1 9 8 7 6 V. High EH2 COM1(RS-232)COM2(RS-485) COM2 RS-232 PC MODEM COM2 Slave Master COM2(RS-485 )PLC COM2 RS-232 V.High , PC HMI 2, 3 EH3 COM3 Slave Master Slave PLC COM2/COM3 PC RS-232 3 Tx 2 Rx Tx 3 Rx 2 7 7 8 8 6 5 GND 1 6 S.G. 5 1 4 4 9 Rl. 9 DB-9 FE MAL E DB-9 FE MAL E PLC COM2/COM3 DOPA 3 Tx 2 Rx Tx 3 Rx 2 7 7 8 8 6 6 5 GND S.G. 5 1 1 4 4 9 9 DB-9 FE MAL E DB-9 MALE PLC COM2/COM3 HITECH 3 Tx 2 Rx Tx 2 Rx 3 7 6 8 8 6 20 5 GND S.G. 7 1 4 4 5 9 DB-9 FE MALE DB-25 MALE DVP-F422 (RS-422 ) EH2 COM2 RS-422 COM2 COM2(RS-485 )PLC COM2 RS-422 COM2 Tx+ Tx- Rx+ RxGND Tx Tx Rx Rx PLC COM2 1 Tx+ 2 Tx3 Rx+ 4 Rx- DOPA Rx+ 2 Rx- 1 Tx+ 3 Tx- 4 6 RTS7 RTS+ 8 CTS+ 9 CTS- D OPA RS-422 COM2 MODE 2 MODE 1: RS-232 MODE 2: RS-422 MODE 3: RS-485 DVP -F4 22 COM2 /DB -9 EH3 COM3 Slave Master F2AD 2 DVP-F2AD 0~10V 0~10V V0+ I0+ CH0 V1+ I1+ CH1 COM 0~20mA V0+ I0+ CH0 0~20mA V1+ I1+ CH1 COM 12VDC () 30mA () (12bit) DC 0~+10V DC 0~20mA 2.5mV (10/4000) 10uA (20/2000) 40K 250 D1118 (K150, ms) 4000 0 10V 2000 0 20mA D1056(CH0) D1110 (CH0) D1057(CH1) D1111 (CH1) D A/D D1118 F2DA 2 DVP-F2DA CH 0 V0+ I0+ 0~+10V CH1 V1+ I1+ 0~+10V COM 1K 500 (12bit) DC 0~+10V DC 0~20mA 0.5 1M 2.5mV (10/4000) 5uA (20/4000) D1118 (K5, ms) D1116 (CH0) D1117 (CH1) 10 V 0 4 0 00 20 mA 0 4 0 00 V0+ CH0 I0+ V1+ CH1 I1+ COM 0~20mA 0~20mA MOV D1116(CH0) D1117(CH1) 0 ~ 500 DVP-F232S (RS-232 ) (DB-9 ) GND NC Rx 5 4 3 Tx NC 2 1 9 8 7 6 NC NC NC NC COM1(RS-232)COM2(RS-485) COM COM( 3 COM3 RS-232 RS-485 COM1 9600/19200/38400 bps COM3 PLC 0.8ms2ms COM2 Slave PC1 WPLSoft/ISPSoft COM3 PC2 WPLSoft/ISPSoft PC1 PC2 COM1 PC HMI 2, 3 DVP-F232 DVP-F485S (RS-485 ) D+ D- D D DVP-F485 (RS-485 ) ( EH3 ) DVP-F485 EH3 D+ D- COM2 Slave Master SG N1 N2 D+ D- 120 N1 D+ N2 Resistor 120 DN1 N2 DVP-512FM DVP-512FM(EH3 ) PLC Off PLC ( On) DVP-512FM PLC -- ( On Off) PLC PC WPLSoft/ISPSoft [][][] WPLSoft/ISPSoft PLC () WPLSoft/ISPSoft 14-30 AWG0.25~1.6 mm 5 kg-cm4.34 in-lbs 60/75°C DVP PLC () DVP-F2AD DVP-F2DA 1~2 DVP-F2DA 1~2 DVP-F2AD EH2 PLC PCHMI DVP-F232S DVP-F485S PLC (PLC ) DVP-512FM EH2 COM2 RS-485 RS-232 DVP-F232 DVP-F422 RS-422 EH2 MODEM PLC EH3 DVP-F232 DI/DO AI/AO DVP-F2AD M1000 M1000 MOV D1056 D0 MOV D1110 D1 MOV D1057 D10 MOV D1111 D11 CH0 AD D0 D1 CH0 CH1 AD D10 D11 CH1 CH0 AD CH1 AD () 4,000 1,472 CH0 D1 K1472 0 ? +10V 1472 10V 3.68V 4000 2,000 1,234 0 ? 20mA () CH1 D11 K1234 1234 20mA 12.34mA 2000 DVP-F2DA M1000 MOV D0 D1116 CH0 M1000 MOV D1 D1117 CH1 CH0 DA CH1 DA 20m A 1,234 0 ? 4,000 ACI 12.34mAD0 12.34mA 4000 2468 20mA 20mA 1,234 0 ? 4,000 AVI 5.23V D1 5.23V 4000 2092 10VAcrobat Distiller 22.0 (Windows)