Models No. HF7200, 7240, 7600 Series OWNER’S MANUAL

OWNER’S MANUAL READ AND SAVE THESE INSTRUCTIONS Models No. HF7200, 7240, 7600 Series Standard Uplight Fan Net Weight 14.51 kg (32 lbs) WARNING: Support Directly From Building Structure For Canada, this fan must be secured directly to the building structure or ceiling joist.

Hubbardton Forge HFLeaf-Std OM

Product Support – Fanimation

PDF preview unavailable. Download the PDF instead.

Hubbardton Forge HFLeaf-Std OM
Leaf Fan Net Weight 16.33 kg
(36 lbs)
Standard Uplight Fan Net Weight 14.51 kg (32 lbs)

Presidio TryneTM Fan Net Weight 16.78 kg
(37 lbs)

WARNING: Support Directly From Building Structure
Models No. HF7200, 7240, 7600 Series
OWNER'S MANUAL
READ AND SAVE THESE INSTRUCTIONS
HUBBARDTON FORGE DESIGN, MANUFACTURED AND DISTRIBUTED BY FANIMATION
For Canada, this fan must be secured directly to the building structure or ceiling joist. Don't secure this fan to an outlet box.

Important Safety Instructions
WARNING: To avoid fire, shock and serious personal injury, follow these instructions.
1. Read your owner's manual and safety information before installing your new fan. Review the accompanying assembly diagrams. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel. 3. Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing. 4. Do not insert anything into the fan blades while the fan is operating. 5. Do not operate reversing switch until fan blades have come to a complete stop.
Additional Safety Instructions
1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades. 2. All wiring and installation procedures must satisfy National Electrical Codes (ANSI/ NFPA 70-1999) and Local Codes. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation should be made or approved by a licensed electrician. 3. The fan base must be securely mounted and capable of reliably supporting at least 50 lbs. (fan and accessories not to exceed 50 lbs. or 22.7 kgs.). See page 4 of owner's manual for support requirements. Consult a qualified electrician if in doubt. WARNING: Mount only to an outlet box marked acceptable for fan support. 4. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades. 5. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not have adequate electrical knowledge or experience, have your fan installed by licensed electrician. 6. Suitable for use with solid-state speed controls.
WARNING: To reduce the risk of fire or electric shock, this fan should only be used with Fan Speed Control Part No. UC7067RC, manufactured by Rhine Electronic Co., Ltd.
WARNING: TO REDUCE THE RISK OF SHOCK, THIS FAN MUST BE INSTALLED WITH AN ISOLATING WALL CONTROL/SWITCH.
WARNING: This product is designed to use only those parts supplied with this product and/or accessories designated specifically for use with this product. Using parts and/or accessories not designated for use with this product could result in personal injury or property damage.
WARNING: To reduce the risk of personal injury, do not bend the blade bracket (flange or blade holder) when installing the brackets, balancing the blades, or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
LIMITED LIFETIME WARRANTY
Extends to the original purchaser of a Fanimation Fan
1. LIMITED LIFETIME MOTOR WARRANTY - If any part of your fan motor fails, due to a defect in materials or workmanship during the lifetime of the original purchaser, Fanimation will provide the replacement part free of charge, when the defective fan is returned to our national service center. Proof of purchase is required. Customer shall be responsible for all costs incurred in the removal or reinstallation and shipping of the product for repairs or replacement. 2. ONE YEAR MOTOR LABOR WARRANTY - If your fan motor fails at any time within one year from the original purchase, due to defects in materials or workmanship, labor to repair the motor will be provided free of charge at our national service center. Purchaser will be responsible for labor charges after this one-year period. Customer shall be responsible for all costs incurred in the removal or reinstallation and shipping of the product for repairs or replacement. 3. If any other part of your fan fails at any time within one year after original purchase, due to a defect in materials or workmanship, we will repair, or replace, at our option, the defective part free of charge for parts and labor performed at our national service center. 4. Because of varying climate conditions, this warranty does not cover changes in the finish, including rusting, pitting, corroding, tarnishing, or peeling. 5. This warranty is void and does not apply to damage from improper installation, neglect, accident, misuse, exposure to extremes of heat or humidity, or as a result of any modification to the original product. 6. All costs of removal and reinstallation of the fan are the sole responsibility of the owner of the fan and not the store that sold the fan or Fanimation. 7. Fanimation reserves the right to modify or discontinue any product at any time and may substitute any part under this warranty. 8. Under no circumstances may a fan be returned without prior authorization from Fanimation. The receipt of purchase must accompany authorized returns and must be sent freight prepaid to Fanimation. The fan to be returned must be properly packed to avoid damage in transit; Fanimation will not be responsible for any damage resulting from improper packaging. 9. It is understood that any repair or replacement is the exclusive remedy available from Fanimation. There is no other expressed or implied warranty. Fanimation hereby disclaims any and all implied warranties, including, but not limited to those of merchantability and fitness for a particular purpose to the extent permitted by law. Some states do not allow limitations on implied warranties. Fanimation will not be liable for incidental, consequential, or special damages arising out of or in conjunction with product use or performance, except as may otherwise be accorded by law. This warranty gives you special legal rights and you may also have other rights that vary from state to state. 10. A certain amount of wobble is normal and should not be considered a problem or a defect.

Table of Contents

Unpacking Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Electrical and Structural Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . 4 How to Assemble Your Down Rod Sleeve . . . . . . . . . . . . . . . . . . . . . . . . 4 How to Assemble Your Ceiling Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 How to Hang Your Ceiling Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 How to Wire Your Ceiling Fan - C22 Remote Control . . . . . . . . . . . . . . . 9 Installing the Canopy Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Assembling and Mounting the Fan Blades . . . . . . . . . . . . . . . . . . . . . . 10 Installing the Receiver Unit and Switch Cup Housing . . . . . . . . . . . . . 11

Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Blade Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Exploded-View Drawing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Installing the Leaf Light Kit ­ LKHF7260BZ. . . . . . . . . . . . . . . . . . . . . . 14 Leaf Light Kit ­ LKHF7260BZ -- Parts Identification . . . . . . . . . . . . . . 15 Installing the Presidio TryneTM Light Kit ­ LKHF7660DS . . . . . . . . . . . 16 Presidio TryneTM Light Kit ­ LKHF7660DS -- Parts Identification. . . . 17 Trouble Shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

This Manual is Designed to Make it as Easy as Possible for You to Assemble, Install, Operate, and Maintain Your Ceiling Fan

Tools Needed for Assembly

Materials

· One Phillips head screwdriver · One wire stripper

· One stepladder

· Three wire connectors

· One ¼ blade screwdriver

(supplied)

WARNING
Before assembling your ceiling fan, refer to section on proper method of wiring your fan (page 4). If you feel you do not have enough wiring knowledge or experience, have your fan installed by a licensed electrician.

Wiring outlet box and box connectors must be of type required by local code. The minimum wire would be a 3conductor (2-wire with ground) of the following size:

Installed Wire Length
Up to 50 ft. 50 - 100 ft.

Wire Size A.W.G.
14 12

NOTE: Place the parts from the loose parts bags in a small container to keep them from being lost. If any parts are missing, contact your local retailer.

Unpacking Instructions
For your convenience, check-off each step. As each step is completed, place a check mark. This will ensure that all
steps have been completed and will be helpful in finding your place should you be interrupted.

WARNING
Do not install or use fan if any part is damaged or missing. This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Fanimation. Substitution of parts or accessories not designated for use with this product by Fanimation could result in personal injury or property damage. Contact your retail store for missing or damaged parts.
1. Check to see that you have received the following parts:
NOTE: If you are uncertain of part description, refer to exploded view illustration. (Figure 1, page 13)

· Fan Motor assembly

· Hardware bags:

­ Support Safety Cable bag ­ Two 5/32 threaded rods

· Five Blade Holders

­ Two 5/32 lockwashers

· Five Wood Blades

­ Two knurled knobs

· Hanger Bracket

­ Two 5/32 Flat head screws

· Downrod/Hanger Ball

­ Sixteen 3/16 screws

assembly

­ Sixteen 3/16 fiber washers

· Downrod Cover assembly ­ Eleven 1/4 screws

· Ceiling Canopy

­ Four wire nuts

· Switch Cup Cover

­ Phillips screwdriver, 4

· Glass

­ Balance Kit

· Housing Fixture

· C22 Remote Control

· Receiver Unit

Hanger Bracket
Downrod/ Hanger Ball Assembly

Wood Blade (5)

Blade Holder (5)

Ceiling Canopy

Receiver Unit

C22 Remote Control

Glass

Downrod Cover Assembly

Fan Motor Assembly

Switch Cup Cover
3

Housing Fixture

Hardware Bag

Electrical and Structural Requirements

Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and capable of withstanding a load of at least 22.7 kgs (50 lbs). Figure 1 depicts different structural configurations that may be used for mounting the outlet box.
WARNING
To reduce the risk of fire, electrical shock, or personal injury, mount fan to outlet box marked acceptable for fan support of 22.7 kg (50 lbs) or less. Use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
If your fan is to replace an existing light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.
WARNING
Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.

Ceiling

Ceiling Joists

Figure 1

2 x 4
Outlet Box

WARNING
To avoid fire or shock, follow all wiring instructions carefully. Any electrical work not described in these instructions should be done or approved by a licensed electrician.

How to Assemble Your Down Rod Sleeve
1. Prior to assembly, set aside and save the hardware bag(s) packed in the packing.

2. Check to see that you have received the following parts (Figure 1).

Sleeve, 8

NOTE: You will be using either the 6 downrod supplied with your fan or an optional downrod purchased separately.

INSTALLATION NOTE
For various Downrod lengths, maintain the distance between 2½ to 3½ from the bottom of Collar to the end of Downrod as shown.

Checkring
Figure 1

Sleeve, 4 Collar (2)

6 Down Rod Assembly: 3. Assemble one Collar with allen wrench provided, as shown (Figure 2).

DR1x6

Collar

2½
Figure 2
4

How to Assemble Your Down Rod Sleeve (cont'd)

12 Down Rod Assembly: 3. Assemble two Collars and 4 Sleeve, as shown (Figure 3).

DR1x12
Collar

Collar Sleeve, 4

3½
Figure 3

18 Down Rod Assembly: 4. Assemble the 18 Down Rod and the Sleeve Kit in the order as shown (Figure 4).

DR1x18

Collar

Collar

Sleeve, 8

2½
Figure 4

24 (or longer) Down Rod Assembly: 5. Assemble the 24 Down Rod and the Sleeve Kit in the order as shown (Figure 5).

DR1x24 or Longer

Checkring
Sleeve, 4 Collar

Sleeve, 8 Collar

3½
Figure 5

5

How to Assemble Your Ceiling Fan

1. Prior to assembly, set aside and save the hardware bag(s) packed in the packing.
2. Remove the Hanger Ball by loosening the setscrew in the Hanger Ball until the ball falls freely down the Downrod. (Figure 1) Remove the Pin from the Downrod, then remove the Hanger Ball. Retain the Pin and Hanger Ball for reinstallation in Step 8.
3. The fan comes with support cable, black and white 80 wires. Separate and untwist the wires & cable. Route the wires & cable through the Downrod.
NOTE: You will be using either the 6 downrod supplied with your fan or an optional downrod purchased separately.
4. Position Fan/Motor Assembly on styrofoam, for ease of assembly.
5. Loosen the two setscrews in the Downrod Support. Align the Clevis Pin holes in the Downrod with the holes in the Downrod Support. Install the Clevis Pin and secure with the Hairpin Clip. (Figure 2) Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin. The hairpin clip must be properly installed to prevent the clevis pin from working loose. Pull on the Downrod to make sure the clevis pin is properly installed. (Figure 2)
6. While pulling up on the hanger ball, securely tighten the two 3/16-24 x 3/8 setscrews in the downrod support. (Figure 2)
7. Install 3 - 40 watt candelabra bulbs (not included) (Figure 3)
NOTE: The setscrews must be properly installed as described above, or fan-wobble could result.

Setscrew
Downrod Support Clevis Pin

Figure 1 Figure 2

Pin Hanger Ball
Hairpin Clip Setscrew (2)

Figure 3

6

How to Assemble Your Ceiling Fan (cont'd)

8. The three screws are pre-assembled onto the Fan Motor assembly. (Figure 4) Remove three screws and use them to attach the Housing Fixture onto the Fan Motor assembly. (Figure 5a)
9. Slide the Glass down until it touches the rubber pads in the Housing Fixture. (Figure 5b)
10. Route wires & cable through opening in Canopy. Position Canopy on fan shown with open side facing up. (Figure 6)
11. Reinstall the Hanger Ball (Figure 3) on the Downrod as follows. Route the three 80 wires through the Hanger Ball. Position the Pin through the two holes in the Downrod and align the Hanger Ball so the Pin is captured in the groove in the top of the Hanger Ball. Pull the Hanger Ball up tight against the pin. Securely tighten the setscrew in the Hanger Ball. A loose setscrew could create fan wobble.
WARNING
It is critical that the clevis pin in the downrod support is properly installed and the setscrews & nuts are securely tightened. Failure to verify that the pin and setscrews are properly installed could result in the fan falling.
12. The fan comes with black and white leads. Before installing fan, measure up approximately 6-9 inches above top of Downrod/Hanger Ball Assembly. Cut off excess wire and strip back insulation ½ from end of wire.
13. You have now completed the assembly of your new ceiling fan. You can now proceed with the hanging and the electrical wiring of your fan.

Figure 4
Figure 5a
Downrod/Hanger Ball Assembly Ceiling Canopy

Figure 5b

Downrod Support

Figure 6

7

How to Hang Your Ceiling Fan

WARNING
To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before hanging. NOTE: If you are not sure if the outlet box is grounded, contact a licensed electrician for advice, as it must be grounded for safe operation.
WARNING
The fan must be hung with at least 7´ of clearance from floor to blades (Figure 1)
WARNING
The outlet box must be securely anchored and capable of withstanding a load of at least 50 lbs. Hanger bracket must seat firmly against outlet box. If the outlet box is recessed, remove wallboard until bracket contacts box. If bracket and/or outlet box are not securely attached, the fan could wobble or fall.
1. Using the 3/8 x 2 lag bolt and flat washer, attach safety cable to ceiling joist or wood structural member. The lag bolt will pass through the flat washer, safety cable loop, the junction box and into the building structure (Figure 2). You will first drill a ¼ pilot hole into the building structure to prevent splitting or cracking.
2. Securely attach the hanger bracket to ceiling junction box acceptable for ceiling support.
NOTE: Ceiling support cable cannot be secured to junction box only, it must be directly secured to ceiling joist or structural member using the  x 2 lag bolt and flat washer. (Figure 2).
3. Make sure the electrical supply wires, including the hanger bracket grounding wire and safety cable are pulled through the downrod, between the hanger bracket and the junction box so that electrical connections can be made later.
4. Carefully lift the fan and seat the downrod/hanger ball assembly on the hanger bracket that was just attached to the ceiling joist. Be sure the groove in the ball is lined up with tab on the hanger bracket. (Figure 3)
5. Attach the safety cable to ceiling support cable. Slide cable clamp onto safety cable (from fan). Place the end of cable through the loop of ceiling support cable. Pull as much cable through loop as possible. Feed end of cable into clamp hole and firmly tighten screw (Figure 3). Cut off excess safety cable.
WARNING
Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard.

No less than
7 ft

Figure 1

Floor

Wood Member (2 x 4 Approx.)

Ceiling Joist

Ceiling
Ceiling Support
Cable

Figure 2

Junction Box
Hanger Bracket

Attach Safety Cable to Ceiling Support
Cable
Tab NOTE: Supply wires and
fan wires omitted for clarity Figure 3

Downrod/Hanger Ball Assembly

WARNING
To avoid possible shock, do not pinch wires between the downrod/hanger ball assembly and the hanger bracket.
8

How to Wire Your Ceiling Fan - C22 Remote Control
If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician.
NOTE: If fan or supply wires are different colors than indicated, have this unit installed by a qualified electrician.
WARNING
To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. NOTE: If you are not sure if the outlet box is grounded, contact a licensed electrician for advice, as it must be grounded for safe operation.

1. Setting the Code: The remote unit has 16 different code combinations. It may be necessary to test a couple of frequency code settings to improve signal reception and/or eliminate interference from other remote control household items. Multiple fans should have different code settings to allow independent fan control. To set the code, perform these steps.
· Transmitter: remove battery cover. Press firmly below arrow and slide battery cover off. Slide code switches to your choice of up or down position. Factory setting is all up. Do not use this position. With a small screwdriver or ball point pen slide firmly up or down (Figure 1a). Replace battery cover on the transmitter.
· Receiver: Slide code switches to the same positions as set on your transmitter (Figure 1b).
2. Wiring & Connecting Your Ceiling Fan: (Figure 2) ­ Green Hanger Bracket and Hanger Ball wires to
BARE (ground) wire. ­ BLACK Fan Motor wire to BLACK supply wire. ­ WHITE Fan Motor wire to WHITE supply wire. · Position all connected wires to allow installation of
ceiling canopy. · Install canopy using threaded rods, lockwashers, and
knurled knobs. (see page 10)
WARNING
Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Do not operate fan until the blades is in place. Noise and fan damage could result.
Operating & Using Remote Transmitter: Install 9 volt battery (If not using for long periods of time, remove battery to prevent damage to transmitter). Store the transmitter away from excess heat or humidity.
· HI Push Button ­ high fan speed · MED Push Button ­ medium fan speed · LOW Push Button ­ low fan speed · REV Push Button ­ toggles between air upflow and
air downflow · OFF Push Button ­ fan off · U/L Push Button ­ use top portion of light button to operate up light · D/L Push Button ­ use bottom portion of light button to operate
optional down light
NOTE: To control either light hold down key to increase or decrease brightness. Tap key quickly to turn light on or off. The light keys have auto resume and will stay at the same brightness as the last time it was turned off.

Remote Transmitter Unit Detail
9V Battery

Receiver Unit Detail

Figure 1a

Figure 1b

WARNING
Total wattage NOT to exceed 300 watts.

BL-AC IN L
GRN or BARE GROUND GRN
BLK-TO MOTOR L WH-TO MOTOR N WH-AC IN N

FAN MOTOR
UNIT

Receiver Unit
BLUE-FOR LIGHT DOWN

Plug from Motor into Receiver Connector

WH-FOR LIGHT DOWN

Figure 2

GRN from hanger ball GRN from bracket
120 VAC SUPPLY (User Supplied)

9

Installing the Canopy Housing
NOTE: This step is applicable after the necessary wiring is completed. (see page 9)
WARNING
To avoid possible fire or shock, make sure that the electrical wires are completely inside the canopy housing and not pinched between the housing and the ceiling.

1. Screw in two threaded rods into the Hanger Bracket (Figure 1).
NOTE: The threaded rods in the hanger bracket serve as guides for easier installation.
2. Securely attach the Canopy Housing to the Hanger Bracket using the external lock washers and knurled knobs supplied with your fan (Figure 2).

NOTE: Supply wires and fan wires omitted for clarity.

Figure 1

Figure 2

Assembling and Mounting the Fan Blades

INSTALLATION NOTE
Do not connect fan blades until the fan is completely installed. Installing the fan with blades assembled may result in damage to the fan blades.

WARNING
To reduce the risk of personal injury, do not bend the blade holders when installing, balancing the blades or cleaning the fan. Do not insert foreign objects in between the rotating blades.
1. Lay blade holder with the threaded posts facing up.
2. Position the wood blade over the blade holder with the threaded posts showing through the holes of the blade.
3. With a Phillips screwdriver, tighten washer-head screws with fiber washers. (Figure 1)
4. Attach assembled blades and blade holders to the motor hub using the provided screws. (Figure 2)
5. Make sure the screws securing the blade holders to the motor hub are tight and that the blade holders are properly seated.
10

Figure 1 Figure 2

Installing the Receiver Unit and Switch Cup Housing

NOTE: This step is applicable for model without lower Light Kits. For Forged Leaf or Presidio TryneTM fan models, skip this section and go to page 14 or 16.
1. Install receiver unit in the switch cup cover by align the two green dots. Carefully connect the main connector & antenna wire connector and push all wires back into switch housing of fan. (Figures 1a and 1b).

IMPORTANT! Align Green Dots

IMPORTANT! Align Orange Dots

WARNING
Check to see that all connections are tight. To avoid possible electrical shock, make sure that the wires are completely inside the switch housing and not pinched between the switch cup base and the housing.
2. Install the assembled switch cup cover (align the two orange dots) using two flat head screws provided. (Figure 2).

Figure 1b

Antenna Wire Connector
Figure 1a

Figure 2

Maintenance

Periodic cleaning of your new ceiling fan is the only maintenance that is needed. When cleaning, use only a soft brush or lint free cloth to avoid scratching the finish. Abrasive cleaning agents are not required and should be avoided to prevent damage to finish.

CAUTION
Do not use water when cleaning your ceiling fan. It could damage the motor or the finish and create the possibility of electrical shock.

Blade Cleaning

Periodic light dusting of the blades is recommended. A feather duster will work best.

Avoid using water, cleansers, or harsh rags, which can warp and ruin the blade and the finish.

11

Parts List
Models #HF7200BZ, #HF7240**, #HF7600DS

Ref. #

Description

Part #

Standard Uplight Fan Assembly

HF7240¾¾

Leaf Fan Assembly (for LK info, see pages 14 & 15)

HF7200BZ

Presidio TryneTM Fan Assembly (for LK info, see pages 16 & 17)

HF7600DS

FAN MOTOR ASSEMBLY -- MAHF7000CY**

1

Hanger Bracket Assembly

APG610BL

2

Ball/Downrod Assembly

3

Downrod Cover Assembly

4

Ceiling Canopy

7

Fan Motor Assembly

8

Blade Holder Set (5)

9

Wood Blade Set (5); Coffee or Slate

ADR1x6¾¾ AP7070¾¾ P7080¾¾ AMA7000¾¾ AP7030¾¾ AP7052¾¾

10

Switch Cup Cover Assembly

AP7020¾¾

11

Receiver Unit

AP7075

12

Remote Control

C22

STANDARD UPLIGHT HOUSING ASSEMBLY -- HAHF7240**

5

Glass, BZ = Stone; DS = Opal

P7040

6

Acharn / Scroll Housing Fixture: BZ or DS

--

Support Cable Bag Containing:

Ceiling Support Cable

Cable Clamp

Flat Washer

Lag Bolt, 3/8 x 2

Loose Parts Hardware Bag Containing:

5/32 Threaded Rods (2)

5/32 External Lockwasher (2)

Knurled Knobs (2) 13
5/32 x 19mm Flat Head Screws (2)

HDWFP7000BL

Wire Nut (4)

Balance Kit

Blade Mount Hardware Bag Containing:

3/16 Pan Head Screw with Washer Head (16)

Fiber Washer (16)

Phillips Screwdriver, 4

Blade Holder Mount Hardware Bag Containing:

¼ Pan Head Screw (11)

¾¾Insert FINISH CODES (Refer to fan model number located on downrod support)

Before discarding packaging materials, be certain all parts have been removed

How To Order Parts

Contact your retail store for repair parts. When ordering repair parts, always give the following information.

· Part Number · Part Description · Fan Model Number

12

Standard Uplight Fan HF7240**
Exploded-View (also for Leaf & Presidio TryneTM Fans)
1
2
4

3 13
9

5 6
7 8
10

12 11

Figure 1 NOTE: The illustration shown is not to scale or its actual configuration may vary
13

Installing the Leaf Light Kit ­ LKHF7260BZ

Leaf Fan Model:
CAUTION
To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before installing light kit.

WARNING
To avoid fire or shock, follow all wiring instructions carefully. Any electrical work not described in these instructions should be done or approved by a licensed electrician.

Figure 1
1. Remove the plug, lockwasher and nut from the bottom of switch cup cover.

Figure 2
2. Mount bowl fitter unit on switch cup cover with lockwasher and nut provided.

IMPORTANT! Align Orange Dots

IMPORTANT! Align Green Dots

Figure 3

Figure 4

3. Locate white and blue wires labeled "FOR LIGHT". Securely connect white-to-white and blue-to-black wires as shown. Push the connectors under the edge of the receiver unit housing.

4. Carefully connect the main connector & antenna wire connector and push all wires back into switch cup housing of fan.

14

Installing the Leaf Light Kit ­ LKHF7260BZ (cont'd)
WARNING
Check to see that all connections are tight. To avoid possible electrical shock, make sure that the wires are completely inside the switch cup housing and not pinched between the housing and the cover.
Figure 6a

Figure 6b

6. Install the Glass bowl with washer and nipple nut provided. (Figure 6a)

Figure 5
5. Reinstall the assembled switch cup cover & fitter using the two flat head screws supplied with your fan. Install three 60 watt candelabra bulbs (not included).

7. Install fixture assembly with the bowl cap and finial nut, do not over tighten. (Figure 6b)
8. Restore power to the fan/light kit assembly.

Leaf Light Kit ­ LKHF7260BZ -- Parts Identification

LEAF FAN ASS'Y ­ HF7200BZ

· MAHF7000BZ - Fan Motor Ass'y/Blades

· HAHF7240BZ - Upper Housing Assembly

1

· LKHF7260BZ - Downlight Stone Glass Bowl

Leaf Down Light Kit Parts List - LKHF7260BZ

Item #

Part #

Qty.

1

AP7024BZ 1

2

P7260ST

1

3

AP7261BZ 1

Description Bowl Fitter Glass, Stone Fixture Assembly

2 3

15

Installing the Presidio TryneTM Light Kit ­ LKHF7660DS

Presidio TryneTM Fan Model:
CAUTION
To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before installing light kit.

WARNING
To avoid fire or shock, follow all wiring instructions carefully. Any electrical work not described in these instructions should be done or approved by a licensed electrician.

Figure 1
1. Remove the plug, lockwasher and nut from the bottom of switch cup cover.

Figure 2
2. Mount bowl fitter unit on switch cup cover with lockwasher and nut provided.

IMPORTANT! Align Orange Dots

IMPORTANT! Align Green Dots

Figure 3

Figure 4

3. Locate white and blue wires labeled "FOR LIGHT". Securely connect white-to-white and blue-to-black wires as shown. Push the connectors under the edge of the receiver unit housing.

4. Carefully connect the main connector and push all wires back into switch cup housing of fan.

16

Installing the Presidio TryneTM Light Kit ­ LKHF7660DS (cont'd)

WARNING
Check to see that all connections are tight. To avoid possible electrical shock, make sure that the wires are completely inside the switch cup housing and not pinched between the housing and the cover.

Figure 6a

Figure 6b

6. Install the Glass bowl with washer and nipple nut provided. (Figure 6a)

Figure 5
5. Reinstall the assembled switch cup cover & fitter using the two flat head screws supplied with your fan. Install three 60 watt candelabra bulbs (not included).

7. Install the bowl cap and finial nut, do not over tighten. (Figure 6b)
8. Restore power to the fan/light kit assembly.

Presidio TryneTM Light Kit ­ LKHF7660DS -- Parts Identification

PRESIDIO TRYNETM FAN ASS'Y ­ HF7600DS

· MAHF7000DS - Fan Motor Ass'y/Blades

· HAHF7240DS - Upper Housing Assembly

1

· LKHF7660DS - Downlight Stone Glass Bowl

Presidio TryneTM Down Light Kit Parts List - LKHF7660DS

Item #

Part #

Qty.

Description

1

AP7023DS 1

Bowl Fitter

2

AP7661OP 1

Glass Ass'y, Opal

2

17

Trouble Shooting
WARNING
For your own safety turn off power at fuse box or circuit breaker before trouble shooting your fan.

Trouble

Probable Cause
1. Fuse or circuit breaker blown.

1. FAN WILL NOT START

2. Loose power line connections to the fan, or loose switch wire connections in the switch housing.

3. Dead battery in remote control.

Suggested Remedy
1. Check main and branch circuit fuses or circuit breakers.
2. Check line wire connections to fan and switch wire connections in the switch housings.
CAUTION: Make sure main power is turned off !
3. Replace with fresh battery.

2. FAN SOUNDS NOISY

1. Loose screws in motor housing. 2. Wire connectors inside housing rattling.
3. Motor noise caused by solid state variable speed control.
4. Screws holding blades to blade holders are loose. 5. Lower housing support set screw loose.

1. Check to make sure all screws in motor housing are snug (not over-tight).
2. Check to make sure wire connectors in switch housing are not rattling against each other or against the interior wall of the switch housing.
CAUTION: Make sure main power is turned off !
3. Some fan motors are sensitive to signals from solid-state variable speed controls. Solid-state controls are not recommended, choose an alternative control method.
4. Tighten screws securely.
5. Tighten set screw securely.

3. FAN WOBBLES EXCESSIVELY

1. Setscrew in downrod support is loose. 2. Setscrew in downrod/hanger ball assembly is loose.
3. Screws securing fan blade holders to motor hub are loose. 4. Hanger bracket and/or ceiling outlet box is not securely fastened.

1. Tighten both setscrews securely in downrod support.
2. Tighten the setscrew in the downrod/hanger ball assembly.
3. Check to be sure screws which attach the fan blade holders to the flywheel are tight.
4. Tighten the hanger bracket screws to the outlet box, and secure outlet box.

4. NOT ENOUGH AIR MOVEMENT

1. If possible, consider using a longer downrod. For example, use a 12" downrod instead of the 6" downrod that comes with your fan.

18

HUBBARDTON FORGE DESIGN, MANUFACTURED AND DISTRIBUTED BY FANIMATION

Copyright 2008 Fanimation

10983 Bennett Parkway Zionsville, IN 46077 (888) 567-2055 FAX (866) 482-5215
Outside U.S. call (317) 733-4113 Visit Our Website www.fanimation.com

All Hubbardton Forge designs, the mark HUBBARDTON FORGE and the design of the tongs are trademarks or registered trademarks of Hubbardton Forge Corporation.

2008/01

