User Manual for HANNA models including: HI97115 Marine Master Waterproof Wireless Multiparameter Photometer, HI97115, Marine Master Waterproof Wireless Multiparameter Photometer, Wireless Multiparameter Photometer, Multiparameter Photometer
14 apr 2023 — The sample cell of these photometers fits a round, glass cuvette with a 25 mm path length. The relatively long path length of the sample cuvette allows the ...6 pagine
File Info : application/pdf, 6 Pages, 2.08MB
DocumentDocumentIP67 waterproof Floating Hanna Lab App Compatible HI97115 Marine Master Waterproof Wireless Multiparameter Photometer Backlit LCD The 128 x 64 Pixel LCD allows for a simplified user interfacer. Method and Parameter Chosen parameter and method used is displayed along with the reading. Battery status indicator and auto-shut off The auto-off feature automatically shuts off the meter after 15 minutes of inactivity in order conserve battery life. Large cuvette size The sample cell of these photometers fits a round, glass cuvette with a 25 mm path length. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples. The cuvette holder features ridges to protect scratching of the optical path by the cuvette. Compact size Measures 142.5 mm (5.6") x 102.5 mm (4") and only 50.5 mm (2") thick. Virtual keys Menu available at the touch of a button Dedicated help A dedicated help key provides information relating to the current meter operation, and can be used at any stage in the setup or measurement process to show contextual help. HI97115 Marine Master Waterproof Wireless Multiparameter Photometer pH, Alkalinity, Ammonia, Calcium, Magnesium, Nitrate Low Range, Nitrate High Range, Nitrite Ultra Low Range, Phosphate Ultra Low Range The HI97115 is a compact and versatile Marine multiparameter photometer designed to accurately determine pH, Alkalinity, Ammonia, Calcium, Magnesium, Nitrate, Nitrite, and Phosphate levels in aquariums and marine biology applications. The HI97115 is suitable for field and bench measurements. The HI97115 can be used as a stand-alone photometer or can be connected to the Hanna Lab App with a compatible smart device via the integrated Bluetooth module. When connected, Hanna Lab App functions include measurement with the ability to add notes, data logging with extended storage capacity, data sharing, and the ability to create and save method groups. Precise and advanced LED optical system Innovative optical design that utilizes a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce little heat, which could otherwise affect electronic stability. Waterproof and floating IP67 meter design Backlit LCD and on-screen help to guide users Includes auto-data logging features to easily record water testing results The instrument features a data autolog function to help users keep track of all measurements. Every time a measurement is made the data is automatically saved. The data log can hold 200 individual measurements. When the data log is full (200 data points), the meter will rewrite the oldest data point. Option to select measurement location for better tracking consistency Built-in reaction timer that ensures consistency between tests. CAL CheckTM validation and calibration Validate instrument performance at any time using CAL Check cuvettes made with NIST traceable standards. The CAL Check screen guides the user step-by-step through the validation process and user calibration. GLP data displays the last calibration date. On-screen tutorial mode with animations The built-in tutorial mode guides users step-by-step through the measurement process. It includes all steps required for sample preparation, the required reagents and quantities. Tutorial mode can be easily enabled or disabled from the setup menu. Positive locking system The Hanna positive-locking system ensures cuvettes are placed into the holder in the same position every time. Hanna Lab App When used with the HI97115, the Hanna Lab App adds an enhanced user experience to a compatible smart device. Features include: measurement with the ability add notes, data logging with extended storage capacity, data sharing, and the ability to create and save method groups.. Samples can be named along with annotations View logged detail with date and time Share logged data in various formats Control meter settings within the Hanna Lab App Specifications Marine pH Range Resolution Accuracy Method LED Marine Alkalinity Range Resolution Accuracy Method LED Marine Ammonia Range Resolution Accuracy Method LED Marine Calcium Range Resolution Marine Magnesium Accuracy Method LED Range Resolution Accuracy Method LED Marine Nitrate Range LR Resolution Accuracy Method LED Marine Nitrate Range HR Resolution Accuracy Method LED Marine Nitrite Range ULR Resolution Accuracy Method LED 6.3 to 8.6 pH 0.1 pH ±0.2 pH of reading at 25 °C Colorimetric Adaptation of the Phenol Red Method 525 nm 0.0 to 20.0 dKH 0.1 dKH ±0.3 dKH ±5 % of reading at 25 °C Colorimetric Method 610 nm 0.00 to 2.50 ppm (as NH) 0.01 ppm ±0.05 ppm ±5% of reading at 25 °C Adaptation of the Salicylate Method 610 nm 200 to 600 ppm 1 ppm ±6% of reading at 25 °C Adaptation of the Zincon Method 610 nm 1000 to 1800 ppm (as Mg2+) 5 ppm ±5% of reading at 25 °C Adaptation of the Colorimetric EDTA Method using calmagite indicator 610 nm 0.00 to 5.00 ppm (as NO) 0.01 ppm ±0.25 ppm ±2% of reading at 25 °C Zinc Reduction Method 525 nm 0.0 to 75.0 ppm (as NO) 0.1 ppm ±2.0 ppm ±5% of reading at 25 °C Zinc Reduction Method 525 nm 0 to 200 ppb (as NO-N) 1 ppb ±10 ppb ±4% of reading at 25 °C Adaptation of the EPA Diazotization Method 354.1 525 nm The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. Marine Phosphate ULR Range Resolution Accuracy Method 0.00 to 0.90 ppm 0.01 ppm ±0.02 ppm ±5% of reading at 25 °C Adaptation of Standard Methods for the Examination of Water and Wastewater, 20th Edition, Ascorbic Acid Method LED 610 nm Measurement system Light source Bandpass filter Light detector LED wavelength bandwidth wavelength accuracy silicon photocell 525 nm & 610 nm 8 nm ±1.0 nm Cuvette Type round 24.6 mm diameter (22 mm inside diameter) Additional Auto logging 200 readings Specifications Display 128 x 64 pixel B/W LCD with backlight Auto-off after 15 minutes of inactivity (30 minutes before a READ measurement) Battery type / Life alkaline 1.5 V AA (3) / > 800 measurements (without backlight) Environment 0 to 50 °C (32 to 122 °F); 0 to 100% RH, non-serviceable Dimensions 142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0") Weight 380 g (13.4 oz.); with batteries Ordering Information Casing IP67 rating, floating HI97115 is supplied with sample cuvette (2 pcs.); sample cuvette cap (2 pcs.); 1.5V AA alkaline batteries (3 pcs.); instrument quality certificate; and quick reference guide with instructions for manual download. CAL Check standards and testing reagents sold separately HI97115C* is delivered in a rugged carrying case and is supplied with sample cuvette (2 pcs.); sample cuvette cap (2 pcs.); marine pH reagent, 30 mL dropper (1 pc.), Marine Alkalinity reagent, 30 mL bottle (1 pc.); Marine Ammonia starter kit - reagent A, 30 mL dropper (1 pc.), reagent B and C (reagent for 25 tests, each); Marine Calcium starter kit - reagent A, 30 mL bottle (1 pc.), reagent B (reagent for 25 tests); Marine Magnesium starter kit - reagent A, 120 mL bottle (1 pc.); Magnesium indicator reagent (for 25 tests); Marine Nitrate High Range reagent (reagent for 25 tests); Marine Nitrite Ultra Low Range reagent (reagent for 25 tests); Marine Phosphate Ultra Low Range reagent (reagent for 25 tests); 1 mL graduated syringe with tip (3 pcs.); minipipette with tip (1 pc.); 3 mL Pasteur pipette (2 pcs.); 5 mL syringe with black printing and tip (1 pc.); 5 mL syringe with blue printing and tip (1 pc.); 1.5V AA alkaline batteries (3 pcs.); cloth for wiping cuvettes; scissors; instrument quality certificate; and quick reference guide with instructions for manual download. CAL Check standards sold separately. Nitrate LR testing reagent not included. *HI97115UC is ordering code for USA Reagents and HI97105-11 CAL CheckTM standards for Marine Master Standards photometer cuvette kit HI758-26 marine calcium reagent - 25 tests HI758U-26 marine calcium reagent - 25 tests (ordering code in the USA) HI764-25 marine nitrite ULR reagent - 25 tests HI772-26 marine alkalinity reagent - 25 tests HI774-25 marine phosphate ULR reagent - 25 tests HI780-25 marine pH Reagent - approx. 100 tests HI781-25 marine nitrate LR Reagent - 25 tests HI782-25 marine nitrate HR reagent - 25 tests HI783-25 marine magnesium reagent - 25 tests HI784-25 marine ammonia reagent - 25 tests Accessories HI70436M Deionized water (230 mL) HI7101419 Blue carrying case for Marine Master photometer HI731318 Cloth for wiping cuvettes (4 pcs.) HI731360 Glass cuvette with cap (2 pcs.) HI731339P 0.1 mL minipipette HI731349P Tip for 0.1 mL minipipette (10 pcs.) HI740142P 1 mL graduated syringe (10 pcs.) HI740143 1 mL graduated syringe (6 pcs.) HI740144P Plastic tip for 5 mL syringe (10 pcs.) HI740157P Plastic refilling pipette (20 pcs.) HI740226 5 mL graduated syringe with black printing (1 pc.) HI740237 5 mL graduated syringe with blue printing (1 pc.) HI740228 Filter disc (25 pcs.) HI740270 10 mL syringe with Luer Lock (1 pc.) HI740271 Filter holder with Luer Lock (1 pc.) HI740272 16 gauge blunt needle (6 pcs.) HI740273 Marine Nitrate LR measurement kit (1 pc.) HI93703-50 Cuvette cleaning solution (230 mL) www.hannainst.com LF_HI97115_1p2_0223