GE Comfort Functions leaflet Modular DIN rail

GE

GE Comfort Functions leaflet Modular DIN rail

Resistent to blocked push-buttons yes. Continuously adjustable time-lag yes. Manual switching (number of positions). 2. Front switch-off lever.

PDF preview unavailable. Download the PDF instead.

GLX Q LUX 1NA 16A 1M
GE Energy Connections

Modular DIN-rail devices

Comfort Functions

N2e0w17

ex.geindustrial.com

Comfort Functions
2 LED Indication Lamp - Aster BL 4 Relays - Contax R 8 Impulse Switches - Pulsar S 14 Staircase Switches - Pulsar SC 16 Universal reliable multifunction - Time Relays 20 Time Relays - Pulsar T+ 24 DIN-rail dimmers - DIM 30 Analogue Time Switches - Classic 32 Digital Time Switches - Galax 36 Time Switches - 72x72 Classic and Galax 38 Light Sensitive Switches - Galax LSS
Numerical index 40 by reference number 41 by catalogue number
1

Modular DIN-rail devices

Comfort Functions
Assembled indication lamps
Aster BL

Applications
Mainly used to visualize the status of a (sub)part of the installation, heater, motor, fan, pump etc.
Standards / Marking
VDE 0633, BS EN 60730-1, BS EN 60730-2-7

Features
Available in different colored leds. UNIVERSAL Current application DC/AC.
Functions
Status visualisation.

Performance

Standards Number of poles Rated voltage U n
Light source Light source capacity W Colours Terminal capacity mm2 Mounting Degree of protection
Ambient air temperature °C Working positions

EN 60 947-5-1 1 VAC 230 VDC 230 high capacity LED diode 0,8 green - G, red - R, blue - B,Yellow-Y 0,75 - 6 for Cu conductors on rail DIN 35x7,5 EN 60 715 IP 20 IP 40 from the front panel from -25 to +55 optional

2

Comfort Functions

Aster BL - Assembled indication lamps

Nominal voltage
230 VAC/DC

Color Red

Number of modules
1

Cat. No. ASTBLR230

Ref. No. Pack. 661692 12

230 VAC/DC

Green

1

ASTBLG230

661693 12

230 VAC/DC

Blue

1

ASTBLB230

661694 12

230 VAC/DC

Yellow /Amber

1

ASTBLY230

661695 12

Aster BL

3

Modular DIN-rail devices

Comfort Functions
Relays
Contax R

Applications
· Switching of lighting, heating, etc. · Galvanic insulation of i.e. status sig-
nalisation lamps from a (high) power (high voltage) circuit. · Galvanic insulation of PLC-inputs or outputs to avoid destruction through excessive voltage.
Standards / Marking
IEC/EN 61095, IEC/EN 60947-4-1, IEC/EN 60947-5-1

Features
· The switch position is visualised by the position of the front handle. · The safety terminals are equipped with captive Pozidriv screws and have
IP20 protection degree. · Add-on auxiliary contacts available. · Because of the advanced product design, no spacers are needed. · Increased safety: sealing caps for both coil and terminal are available.
Functions
Relays are electromechanically controlled switches used to control low power loads.

4

Contax R

Performance

Rated current (according to EN 60947-4-1)

230VAC (1 and 2 pole) / 400VAC (3 and 4 pole)

Nominal thermal current (Ith)

Number of pole

Contacts

NO

Changeover

NO + NC

Width (in 17.8mm DIN modules)

1P and 2P

3P and 4P

Coil specifications

Supply voltage range (in % of Un)

Coil voltage frequency

Coil pick-up power

1P and 2P

3P and 4P

Coil power loss - AC

1P and 2P

3P and 4P

Maximum coil holding voltage time

Contact bounce time at closing

Operate and release time

Pick-up time

NO contact

(from 0 to Un)

NC contact

Drop-out time

NO contact

(from Un to 0)

NC contact

Maximum peak current at closing Single phase 230VAC cos j = 0.95

3-phase

400V~ cos j = 0.65

Maximum peak current at opening

Single phase 230VAC cos j = 0.95

3-phase

400V~ cos j = 0.65

Lifetime (in number of operations)

Electrical (in AC-1 - At full load)

Mechanical

Load specifications per phase

Maximum load AC-1

1P and 2P

3P and 4P

Maximum load AC-5b

Maximum load AC-7b

Maximum load AC-3

230VAC

400VAC

Minimum load (under 5V)

Short-circuit fuse protection

General specifications

Auxiliary contact add-on (CTX R)

Need for spacer

DIN rail mounting

Front handle for manual operation

Permanent ON/OFF

Indicator of contact position

Clamping terminals

Unlosable screws

Sealable terminals (coil and load)

Cable cross section (Ø min/max)

Coil

Load

Maximum torque on terminals

Coil / load

Ambient temperature at installation point (min./max.)

Comfort Functions

A A
Mod. Mod.
% Hz VA VA VA VA sec. sec. sec. sec. sec.
kW kW kW kW kW kW W A
mm² mm² Nm
°C

Contax R
16 16 1  4 1  4 1  2 1+1 / 2+2 1 2
85-110 50/60
10 25 1.2 1.6 unlimited <0.010
<0.025 <0.025 <0.030 <0.030
70 70
56 56
2x105 3x106
2.9 8.8 2.0 1.1 1.1 3.0 2 16
yes no yes yes no yes yes yes yes 1.0 / 2.5 1.0 / 10 0.6 / 1.2 -15 / 55

5

Comfort Functions

Modular DIN-rail devices

Impulse switches, Contax L and relays: maximum lamp loads

Lamps type

Lamp Watts Pulsar S Pulsar S Power PULSAR16 PULSAR 32
consumption

Incandescent lamps Max. load 230VAC Max. number of lamps

Fluo lamp PF uncorrected Max. load 230VAC Max. number of lamps
Fluo twin lamps Max. load 230VAC Max. number of lamps
Fluo lamp parallel compensation Max. load 230VAC Max. number of lamps
Halogen 230V Max. load 230VAC Max. number of lamps
HP sodium vapour Max. load 230VAC Max. number of lamps
LP sodium vapour Max. load 230VAC Max. number of lamps
HP mercury vapour Max. load 230VAC Max. number of lamps
VLV halogen Max. load 230VAC Max. number of lamps

Electronic reactor Max. load 230VAC Max. number of lamps

LEDs Max. load 230VAC

Non dimmable

15W 25W 40W 60W 75W 100W 150W 200W 300W 500W
18W 36W 40W 58W 65W
2x18W 2x36W 2x40W 2x58W 2x65W
18W 36W 40W 58W 65W
150W 250W 300W 400W 500W 1000W
70W 150W 250W 400W 1000W
55W 90W 135W 180W 185W
50W 80W 125W 250W 400W 1000W
20W 50W 75W 100W 150W 200W 300W
1x18W 1x36W 1x58W 2x18W 2x36W 2x58W

2100W 133 80 50 33 27 20 13 10 7 4
1560W 43 37 37 24 24
2730W 62 33 33 21 21
720W 18 18 18 11 11
2100W 13 8 7 5 4 2
1200W 13 7 4 3 1
1800W 15 10 10 10 9
1250W 17 13 8 5 3 1
1050W 50 20 14 10 7 5 3
720W 33 19 11 18 10 5
2A

3600W 233 140 88 58 47 35 23 18 12 7
1560W 43 37 37 24 24
2730W 62 33 33 21 21
1365W 33 33 33 21 21
3600W 23 14 12 9 7 4
1600W 16 9 5 4 1
2880W 27 18 18 16 15
2000W 27 20 13 7 5 2
3000W 150 60 40 30 20 15 10
2800W 133 75 43 71 39 21
12A

Contax R
2100W 133 80 50 33 27 20 13 10 7 3
845W 24 20 20 13 13
1360W 31 17 17 10 10
390W 7 7 7 4 4
2100W 13 8 7 5 4 2
800W 9 5 3 2 -
540W 7 4 3 3 2
1000W 14 10 7 4 2 1
1050W 50 20 14 10 7 5 3
470W 22 13 7 12 6 4
1.5A

Contax L Contax L Contax L Contax L

Contactors Contactors Contactors Contactors

20A

25A

40A

63A

2100W 133 80 50 33 27 20 13 10 7 4
845W 24 20 20 13 13
1360W 31 17 17 10 10
390W 7 7 7 4 4
2100W 13 8 7 5 4 2
800W 9 5 3 2 -
540W 7 4 3 3 2
1000W 14 10 7 4 2 1
1050W 50 20 14 10 7 5 3
470W 22 13 7 12 6 4

2220W 147 88 55 37 29 22 15 11 7 4
1105W 30 26 26 17 17
1760W 40 22 22 13 13
325W 8 8 8 5 5
2250W 15 9 7 6 4 2
1000W 10 6 4 2 1
720W 9 5 4 4 3
1250W 18 13 9 5 3 1
1200W 60 24 16 12 8 6 4
720W 35 20 11 19 10 6

4050W 267 160 100 67 53 40 27 20 13 8
1950W 54 47 47 30 30
4320W 100 54 54 33 33
2015W 49 49 49 31 31
4050W 27 16 13 10 8 4
2500W 30 17 10 6 3
1800W 23 14 10 10 9
3000W 38 29 20 10 7 3
2700W 135 54 36 27 18 14 9
2090W 100 56 32 53 29 16

5100W 333 200 125 83 67 50 33 25 17 10
3120W 86 74 74 48 48
6500W 150 81 81 50 50
3055W 73 73 73 47 47
5100W 33 20 17 13 10 5
3300W 35 22 13 8 3
2340W 30 19 13 13 12
4000W 55 42 29 15 10 4
4350W 215 86 57 43 29 22 14
2880W 139 78 45 74 40 22

2.4A

3.8A

11A

18A

Dimmable

2A

12A

1.5A

2.4A

3.8A

11A

18A

6

Contax R

Comfort Functions

Contax R - Relays

1 NO

Nominal current
16A 16A 16A 16A 16A 16A 16A

Contact Coil voltage Number of

combination AC

Modules

1 NO

8V

1

1 NO

12V

1

1 NO

24V

1

1 NO

48V

1

1 NO

115V

1

1 NO

230V

1

1 NO

240V

1

Cat. No.
CONTAXR1610008A CONTAXR1610012A CONTAXR1610024A CONTAXR1610048A CONTAXR1610115A CONTAXR1610230A CONTAXR1610240A

1 CO

16A

16A

16A

16A

16A

16A

16A

1 CO 1 CO 1 CO 1 CO 1 CO 1 CO 1 CO

8V 12V 24V 48V 115V 230V 240V

1

CONTAXR161008A

1

CONTAXR161012A

1

CONTAXR161024A

1

CONTAXR161048A

1

CONTAXR161115A

1

CONTAXR161230A

1

CONTAXR161240A

2 NO

16A

16A

16A

16A

16A

16A

16A

2 NO 2 NO 2 NO 2 NO 2 NO 2 NO 2 NO

8V 12V 24V 48V 115V 230V 240V

1

CONTAXR1620008A

1

CONTAXR1620012A

1

CONTAXR1620024A

1

CONTAXR1620048A

1

CONTAXR1620115A

1

CONTAXR1620230A

1

CONTAXR1620240A

1 NO 1 NC

16A

1 NO 1 NC

8V

16A

1 NO 1 NC

12V

16A

1 NO 1 NC

24V

16A

1 NO 1 NC

48V

16A

1 NO 1 NC

115V

16A

1 NO 1 NC

230V

16A

1 NO 1 NC

240V

1

CONTAXR1611008A

1

CONTAXR1611012A

1

CONTAXR1611024A

1

CONTAXR1611048A

1

CONTAXR1611115A

1

CONTAXR1611230A

1

CONTAXR1611240A

2 CO

16A

16A

16A

16A

16A

16A

16A

2 CO 2 CO 2 CO 2 CO 2 CO 2 CO 2 CO

8V 12V 24V 48V 115V 230V 240V

2

CONTAXR162008A

2

CONTAXR162012A

2

CONTAXR162024A

2

CONTAXR162048A

2

CONTAXR162115A

2

CONTAXR162230A

2

CONTAXR162240A

3 NO

16A

16A

16A

16A

3 NO 3 NO 3 NO 3 NO

12V 24V 48V 230V

2

CONTAXR1630012A

2

CONTAXR1630024A

2

CONTAXR1630048A

2

CONTAXR1630230A

4 NO 2 NO 2 NC

16A

4 NO

8V

16A

4 NO

12V

16A

4 NO

24V

16A

4 NO

48V

16A

4 NO

230V

16A

4 NO

240V

16A

2 NO 2 NC

8V

16A

2 NO 2 NC

12V

16A

2 NO 2 NC

24V

16A

2 NO 2 NC

48V

16A

2 NO 2 NC

230V

16A

2 NO 2 NC

240V

2

CONTAXR1640008A

2

CONTAXR1640012A

2

CONTAXR1640024A

2

CONTAXR1640048A

2

CONTAXR1640230A

2

CONTAXR1640240A

2

CONTAXR1622008A

2

CONTAXR1622012A

2

CONTAXR1622024A

2

CONTAXR1622048A

2

CONTAXR1622230A

2

CONTAXR1622240A

Ref. No. Pack.
685693 1 685694 1 685695 1 685696 1 685697 1 685699 1 685700 1
685701 1 685702 1 685703 1 685704 1 685705 1 685706 1 685707 1
685708 1 685709 1 685710 1 685711 1 685712 1 685714 1 685715 1
685716 1 685717 1 685718 1 685719 1 685720 1 685722 1 685723 1
685724 1 685725 1 685726 1 685727 1 685728 1 685729 1 685730 1
685731 1 685732 1 685733 1 685734 1
685735 1 685736 1 685737 1 685738 1 685740 1 685741 1
685742 1 685743 1 685744 1 685745 1 685747 1 685748 1

Sealing covers

-

1

CONTAXR1CAP

-

2

CONTAXR2CAP

685945 2 685934 2

Add-on auxiliary contact

6A

1NO 1NC

-

1 NO 1 NC

2 NO

6A

2NO

-

0.5

CONTAXRAUX11

0.5

CONTAXRAUX20

685883 1 685930 1

7

Modular DIN-rail devices

Comfort Functions
Pulsar Impulse switches range
Impulse switches are switching devices without power consumption in operating switch-on position and very small power consumption per pole. On a very effective way helps to reduce greenhouse gas emissions of C02.
Main Benefits
Small switch on coil consumption No hold coil consumption Wide application Mounting on 35mm rail Sealing terminal covers All control voltages from 8V till 240V are possible For remote switching Advanced operation Lights and lighting Electric heating Electric drives Intelligent installations Impulse control Manual control

Main features
· Redline shape · Pozidriv screws · Market terminals · Electric diagram in front of the device

Plenty of accessories
· Sealing cover · Capacitor · Auxiliaries · General command · Multilevel

8

Full functionality FULL FUNCTIONALITY

Comfort Functions

Introduction

Multilevel Central Command

Local ON/OFF

Local ON/OFF

Local ON/OFF

3 Level ON

3 Level OFF
Impulse switches with central command

Multilevel Central Command

Local ON/OFF

Local ON/OFF

Local ON/OFF

2 Level ON

2 Level OFF
Impulse switches with central command

Multilevel ON

Multilevel Central Command

Local ON/OFF

Local ON/OFF

Local ON/OFF

Multilevel OFF

1 Level ON 1 Level OFF
Impulse switches with central command
9

Modular DIN-rail devices

Comfort Functions
Impulse switches
Pulsar S

Applications
Mainly used for the switching of lighting and heating equipment and/or to obtain a simplified wiring in case the load needs to be controlled at reduced voltage and/or from more than 2 different places.
Standards / Marking
IEC/EN 60669-1, IEC/EN 60669-2-2

Features
· Besides the normal operation through electrically energising the coil, manual operation is possible at all times.
· The switch position is visualised by the position of the front handle for all devices.
· The central command version was developed to force several devices at the same time to the on or off position, independently of the current status of each individual device. Also in this case, the possibility of operating the device locally remains.
· The safety terminals are equipped with captive Pozidriv screws and have IP20 protection degree.
· An add-on auxiliary contact, add-on central-command module and a spacer are available.
· The use of a large number of luminous push-buttons is possible. · Availability of sealing cap for coil and load terminals.
DIN-rail positioning: used in vertical/horizontal position
Functions
Impulse switches are electromechanically controlled switches used to control single- or multi-phase medium-power loads while the control itself can be (very) low power. The device switches between 2 stable positions, each time a (brief) impulse energises its control circuit.

10

Pulsar S

Comfort Functions

Performance

Rated current (according to IEC/EN 60669-2-2)

250VAC (1 pole) / 440V AC (2, 3 and 4 pole)

Direct current (at 30V DC)

Number of pole

Contacts

NO

Changeover

NO + NC

Width (in 17.8mm DIN modules)

1 P

2 P

3 P

4 P

Coil specifications

Supply voltage range (in % of Un)

Coil pick-up power

1P and 2P

3P and 4P

Coil power loss - AC

1P and 2P

3P and 4P

Maximum coil holding voltage time

Impulse times

Minimum impulse time (under Un)

Minimum impulse time (90% Un)

Minimum time between impulses

Maximum number of impulses per hour

Lifetime (in number of operations)

Electrical (AC - At full load)

Mechanical

Load specifications

Maximum load AC-1

Maximum load DC (30V DC)

Minimum load per phase (under 5V)

Short-circuit fuse protection

Maximum number of push-buttons

Non illuminated push-buttons

Luminous push-buttons (0.6mA)

Without compensator

1 compensator

2 compensators

General specifications

Auxiliary contact add-on (PLS)

Need for spacer (up to 40°C)(1)

DIN rail mounting

2-POSITION HANDLE

Indicator of contact position

Clamping terminals

Unlosable screws

Sealable terminals (coil and load)

Cable cross section (Ø min/max)

Coil

Load 1P-3P and 4P

Load 2P

Coil / Load

Ambient temperature at installation point (min./max.)

PLS + 16

A

16

A

16

1  4

1  4 1  2 1+1 / 2+2

Mod.

1

Mod.

1

Mod.

2

Mod.

2

%

90-110

VA

18

VA

18

VA

9

VA

9

1h

sec.

0.050

sec.

0.100

sec.

0.150

900

2x105 2x106

A

16

A

16

W

2

A

16

unlimited

4 30 50

mm² mm²
mm² °C

yes no yes yes yes yes yes yes 1 / 4 1 / 10 1 / 10 1.2 / 0.6 -25 / 55

PLS +

PLS + C

PLS + 32 PLS + PU 16 PLS + C 16 PLS + C 32

32 20 1  4

16 16 1  4

16 16 1  4

32 20 1  3

1  4

1  4

1  3

-

-

1  2

1  2

-

-

1+1 / 2+2

-

-

1

1

1

1

1

1

1 ½

1 ½

2

2

-

2 ½

2

2

2 ½

-

90-110 18 18 9 9 1h

90-110 18 18 9 9
permanent

90-110 18 18 9 9 1h

90-110 18 18 9 9 1h

0.050 0.100 0.150 450

0.050 0.100 0.150 900

0.050 0.100 0.150 900

0.050 0.100 0.150 600

2x105 2x106

2x105 2x106

2x105 2x106

2x105 2x106

32

16

16

32

20

16

16

20

2

2

2

2

32

16

16

32

unlimited unlimited unlimited unlimited

4

4

4

4

30

30

30

30

50

50

50

50

yes no yes yes yes yes yes yes 1/ 4 1 / 10 1 / 10 1.2 / 0.6 -25 / 55

yes yes yes yes yes yes yes yes 1 / 4 1 / 10 1 / 10 1.2 / 0.6 -25 / 55

no no yes yes yes yes yes yes 1 / 4 1 / 10 1 / 10 1.2 / 0.6 -25 / 55

no no yes yes yes yes yes yes 1 / 4 1 / 10 1 / 10 1.2 / 0.6 -25 / 55

(1) F or temperatures 40 ... 55°C the spacer is required on the side of 3 switches side-by-side and for temperatures 55 ... 70 °C the spacer is required on the side of each switch.

11

Modular DIN-rail devices

Comfort Functions

Pulsar S - Impulse switches

Impulse switches 1NO

Nominal current
16A 16A 16A 16A 16A 16A 16A 16A

Contact Coil voltage Number of

combination AC

modules

1NO

8V

1

1NO

12V

1

1NO

24V

1

1NO

48V

1

1NO

115V

1

1NO

230V

1

1NO

230V/60Hz

1

1NO

240V

1

Cat. No.
PULSAR1610008A PULSAR1610012A PULSAR1610024A PULSAR1610048A PULSAR1610115A PULSAR1610230A PULSAR16123060 PULSAR1610240A

1CO

16A

16A

16A

16A

16A

16A

16A

1CO

8V

1CO

12V

1CO

24V

1CO

48V

1CO

115V

1CO

230V

1CO

240V

1

PULSAR161008A

1

PULSAR161012A

1

PULSAR161024A

1

PULSAR161048A

1

PULSAR161115A

1

PULSAR161230A

1

PULSAR161240A

2NO

16A

16A

16A

16A

16A

16A

16A

16A

2NO

8V

1

2NO

12V

1

2NO

24V

1

2NO

48V

1

2NO

115V

1

2NO

230V/60Hz

1

2NO

230V

1

2NO

240V

1

PULSAR1620008A PULSAR1620012A PULSAR1620024A PULSAR1620048A PULSAR1620115A PULSAR162023060 PULSAR1620230A PULSAR1620240A

1NO 1NC

16A

1NO 1NC

8V

1

16A

1NO 1NC

12V

1

16A

1NO 1NC

24V

1

16A

1NO 1NC

48V

1

16A

1NO 1NC

115V

1

16A

1NO 1NC

230V

1

16A

1NO 1NC 230V/60Hz

1

16A

1NO 1NC

240V

1

PULSAR1611008A PULSAR1611012A PULSAR1611024A PULSAR1611048A PULSAR1611115A PULSAR1611230A PULSAR161123060 PULSAR1611240A

2CO

16A

16A

16A

16A

16A

16A

16A

2CO

8V

2CO

12V

2CO

24V

2CO

48V

2CO

115V

2CO

230V

2CO

240V

2

PULSAR162008A

2

PULSAR162012A

2

PULSAR162024A

2

PULSAR162048A

2

PULSAR162115A

2

PULSAR162230A

2

PULSAR162240A

1NO

32A

32A

32A

32A

32A

32A

32A

1NO

8V

1NO

12V

1NO

24V

1NO

48V

1NO

115V

1NO

230V

1NO

240V

1

PULSAR3210008A

1

PULSAR3210012A

1

PULSAR3210024A

1

PULSAR3210048A

1

PULSAR3210115A

1

PULSAR3210230A

1

PULSAR3210240A

2NO

32A

32A

32A

32A

32A

32A

32A

2NO

8V

2NO

12V

2NO

24V

2NO

48V

2NO

115V

2NO

230V

2NO

240V

1

PULSAR3220008A

1

PULSAR3220012A

1

PULSAR3220024A

1

PULSAR3220048A

1

PULSAR3220115A

1

PULSAR3220230A

1

PULSAR3220240A

Ref. No. Pack.
685779 1 685780 1 685781 1 685782 1 685783 1 685784 1 685785 1 685786 1
685787 1 685788 1 685789 1 685790 1 685791 1 685792 1 685793 1
685794 1 685795 1 685796 1 685797 1 685798 1 685799 1 685800 1 685801 1
685802 1 685803 1 685804 1 685805 1 685806 1 685807 1 685808 1 685809 1
685810 1 685811 1 685812 1 685813 1 685814 1 685815 1 685816 1
685817 1 685818 1 685819 1 685820 1 685821 1 685822 1 685823 1
685824 1 685825 1 685826 1 685827 1 685828 1 685829 1 685830 1

12

Pulsar S

Comfort Functions

Pulsar S - Impulse switches

All-in central command 1NO 1CO 2NO 2CO 1NO 2NO 3NO

Nominal current
16A 16A 16A 16A 16A 16A

Contact Coil voltage Number of

combination AC

modules

1NO

8V

1.5

1NO

12V

1.5

1NO

24V

1.5

1NO

48V

1.5

1NO

230V

1.5

1NO

240V

1.5

Cat. No.
PULSARC1610008A PULSARC1610012A PULSARC1610024A PULSARC1610048A PULSARC1610230A PULSARC1610240A

16A

1CO

8V

1.5

PULSARC161008A

16A

1CO

12V

1.5

PULSARC161012A

16A

1CO

24V

1.5

PULSARC161 024A

16A

1CO

48V

1.5

PULSARC161048A

16A

1CO

230V

1.5

PULSARC161230A

16A

1CO

240V

1.5

PULSARC161240A

16A

2NO

8V

1.5

PULSARC1620008A

16A

2NO

12V

1.5

PULSARC1620012A

16A

2NO

24V

1.5

PULSARC1620024A

16A

2NO

48V

1.5

PULSARC1620048A

16A

2NO

230V

1.5

PULSARC1620230A

16A

2NO

240V

1.5

PULSARC1620240A

16A

2CO

8V

2.5

PULSARC162008A

16A

2CO

12V

2.5

PULSARC162012A

16A

2CO

24V

2.5

PULSARC162024A

16A

2CO

48V

2.5

PULSARC162048A

16A

2CO

230V

2.5

PULSARC162230A

16A

2CO

240V

2.5

PULSARC162240A

32A

1NO

8V

1.5

PULSARC3210008A

32A

1NO

12V

1.5

PULSARC3210012A

32A

1NO

24V

1.5

PULSARC3210024A

32A

1NO

48V

1.5

PULSARC3210048A

32A

1NO

230V

1.5

PULSARC3210230A

32A

1NO

240V

1.5

PULSARC3210240A

32A

2NO

8V

1.5

PULSARC3220008A

32A

2NO

12V

1.5

PULSARC3220012A

32A

2NO

24V

1.5

PULSARC3220024A

32A

2NO

48V

1.5

PULSARC3220048A

32A

2NO

230V

1.5

PULSARC3220230A

32A

2NO

240V

1.5

PULSARC3220240A

32A

3NO

8V

2.5

PULSARC3230008A

32A

3NO

12V

2.5

PULSARC3230012A

32A

3NO

24V

2.5

PULSARC3230024A

32A

3NO

48V

2.5

PULSARC3230048A

32A

3NO

230V

2.5

PULSARC3230230A

32A

3NO

240V

2.5

PULSARC3230240A

Permanent use

16A

2NO

16A

2CO

16A

16A

4NO

16A

16A

2NO

24V

2NO

230V

2CO

24V

2CO

230V

4NO

24V

4NO

230V

1

PULSARPU162024A

1

PULSARPU162230A

2

PULSARPU1620024A

2

PULSARPU1620230A

2

PULSARPU1640024A

2

PULSARPU1640230A

Ref. No. Pack.
685831 1 685832 1 685833 1 685834 1 685835 1 685836 1
685837 1 685838 1 685839 1 685840 1 685841 1 685842 1
685843 1 685844 1 685845 1 685846 1 685847 1 685848 1
685849 1 685850 1 685851 1 685852 1 685853 1 685854 1
685855 1 685856 1 685857 1 685858 1 685859 1 685860 1
685861 1 685862 1 685863 1 685864 1 685865 1 685866 1
685867 1 685868 1 685869 1 685870 1 685871 1 685872 1
685873 1 685874 1
685875 1 685876 1
685877 1 685878 1

Add-on auxiliary contact

1NO 1NC 2NO

6A

1NO 1NC

-

6A

2NO

-

Add-on central control

-

-

-

0.5

PULSARAUX11

0.5

PULSARAUX20

0.5

PULSARC

685879 1 685880 1 685881 1

Multilevel central

-

command module

Capacity module

-

Sealing cap

-

Spacer

-

-

-

0.5

PULSARM

-

230/240V

-

PULSARCAPM

-

-

1

PULSARCAP

-

-

0.5

PLC/CTX SP

685882 1
685884 1 685885 2 686069 50
13

Comfort Functions
Staircase switches
Pulsar SC

Modular DIN-rail devices

Applications
Lighting or ventilation of staircases. basements, halls, etc
Standard
EN 60669-2-1

Features
· Designed for a real 4.000W switching capacity. · User adjustable time. · 3 or 4 wire wiring possible. · Safety terminals equipped with captive PH screws and IP20 protection degree. · Anti vandalisme: resistant to blocked push-buttons.
Functions
The staircase switch Pulsar SC is an electronic switching device with microdistance (µ) of opening between contacts. It manages over time the lights permanence in rooms such as hallways, stairs, cellars to avoid wiasting energy.

14

Pulsar SC - Staircase switches

Electronic staircase switch 1 NO

Nominal Contact Current Combination

Coil Voltage
AC

Coil Number of Voltage modules
DC

Cat. No.

Ref. No. Pack.

16A

1 NO 230 V AC(-15%...+10%) -

1

PULSAR SC 1-15 16A 1M 687474 1

Automatic

Power supply ON OFF

Push-buttons ON OFF

Relay

ON

OFF

T

<T

<T

T

Staircase light xed on

Power supply ON OFF

Push-buttons ON OFF

Relay

ON

OFF

Pulsar SC

Comfort Functions

Performance

Rated current (acc. IEC 669-2-3)

Width

(in number of DIN-modules)

Contacts

Time range

Supply voltage

Supply voltage range (in % of Un)

Rated power consumption

Closed circuit current

Working current (ignition and running)

Light types

Incandescent lamps

Fluorescent lamps

LED

Load type P max

Incandescent lamps (230V)

Fluorescence lamps (230V)

LED (<2W)

LED (2-8W)

LED (>8W)

Lifetime (in number of operations)

Electrical

Mechanical Max. number of push-buttons
Non illuminated push-buttons Luminous push-buttons: General specifications DIN-rail mounting Silent operations 3-wire and 4-wire installation Resistent to blocked push-buttons Continuously adjustable time-lag Manual switching (number of positions) Front switch-off lever Clamping screw terminals, unloosable screws Cable cross section (Ø min/max) Maximum torque on terminals Ambient temperature at installation point (min./max.) Storage temperature

A

NO 2 function 230V - 50/60 Hz
%

230V

VA

230V

VA

W W W W W
at 1200W at full load

Coil Load

mm2 mm2 N x m
ºC ºC

PULSAR SC 16 1 1
30 sec. - 20 min. yes
85 - 110
6 (1W) 6 (1W)
yes yes yes
4000 1000
55 150 180
5.104 1.105 1.107
unlimited 50 (1mA)
yes yes yes yes yes 2 yes 4 1.0 / 2.5 0.6 0 / +50 -10 / +60

Wiring diagram
3 wire connecting diagram

4 wire connecting diagram

15

Universal reliable multifunction

Multifunction Time Relays
Ten functions: - Five time functions controlled via supply voltage - Four time functions controlled via control input - One latching relay function Used for regular room ventilation, cyclic dehumidification, light control, circulating pumps, neon signs, etc.

Asymmetrical cycle Time Relay
Used for warning illumination on the road, flashers, cyclers, frequently-switched systems

Time Relay
Time Relay is defined as the controlled period between two operations. A Time relay is a combination of an electromechanical output relay and a control circuit. The control circuit comprises solid-state components and timing circuits that control the operation of the relay and the timing range.
Over time, advances in electronic technology have greatly increased the number and variety of applications available for industrial modular relays. Selecting a relay can often be difficult and confusing task. Hopefully, this brief explanation will help you to understand which factors to consider when selecting a time relay.
Relays perform the crucial function of using one level of voltage to control what is often a different level of voltage. They also provide a high degree of isolation between power wiring and control wiring. Time relays add an extra dimension in terms of application, as they allow the introduction of a time element into the control circuit. It is virtually impossible to design a control circuit in a system without using time relays.

The PLT+ Time relays range is highly versatile, it provides the basic switching or controlling function as mentioned, and the timing functions in the circuit. The PLT+ range is compact in size, with a modular 18 mm-width shape, and offers unrivalled performance in its function. Time relay contacts are rated from 8Amp. (3 COM contacts in only 1 mod.) to 16Amp. AC1.
Timing functions for the PLT+ time relays range include: Delay ON after energization, Delay OFF after energization, Cycler beginning with pause after energization, Cycler beginning with impulse after energization, Delay OFF after de-energization, Instant make of output, Delay OFF responding to make of control contact regardless its length, Delay OFF after break of control contact with instant output, Delay OFF after make and break of control contact, Impulse relay, Pulse generator, Asymmetrical Cycler beginning with pulse, Asymmetrical Cycler beginning with pause.
Timing values may be set using a rotary switch and potentiometer in the front of the device, from 0.1 seconds to 10 days.

Save energy
Examples of Use - Stagger start of motors to limit inrush current. - Security systems, delay system lockdown for a set period.
This allows the person setting the alarm to clear the area. - Stairwell light operated via momentary "ON" switch. - Switch OFF delay of toilet exhaust fan. If used in conjunction
with a light circuit, the timer will allow the fan to continue to operate (for a set delay time) after the light has been turned OFF. - When connected to the main light switch, a True OFF delay timer allows the last person sufficient time to clear the building before all the lights are turned off. - Running a discharge pump for 1 hour per every 10-hour cycle. - Turning a beacon "ON" for 2 seconds per every 6-second cycle.

Time Relays

Performances and features
Multifunction Time Relays

Comfort Functions
Functions

Supply terminals

Control. input "S"

Supply indication Rough time setting
Fine time setting Function setting

Output indication

Multifunctional cycle Time Relay (MF)

Output contact(s)

0.1 - 1 s

1 - 10 s

0.1 - 1 min 1 - 10 min

0.1 - 1 h

1 - 10 h

0.1 - 1 day 1 - 10 days fixed ON

fixed OFF

Rough time setting - IMPULS time setting in range 0.1 .. 10 days

Asymmetrical cycle Time Relay (AS)
Fine time setting - IMPULS fluent setting of rough range

Rough time setting - IMPULS /PAUSE Fine time setting - IMPULS /PAUSE

time setting in range 0.1 .. 100 days

fluent setting of rough range

0.1 - 1 s

1 - 10 s

0.1 - 1 min 1 - 10 min

0.1 - 1 h

1 - 10 h

0.1 - 1 day 1 - 10 days 3 - 30 days 10 - 100 days

17

Temporize/Dim whatever you want

Our new DIM range dimmers have been specifically created to control R, L, C, LED light sources (dimmable) and energy-saving lamps. The DIM RANGE is designed to be mounted on a DIN-rail onto panelboard. These dimmers have a number of characteristics that make them rank amongst the best on the market:

- The option to set the minimum brightness of the lamp - which eliminates flashing.
- Built-in protection, meaning that the light source will neither flash nor change brightness when the input voltage fluctuates. This dimmer is designed for use in a house, apartment or office.

Reading

Enjoy a movie

PARTY!

Falling asleep

Dim it. And enjoy yourself Conjure up rainbows of intense colour when watching fairy tales. Or do you like horror films? Bathe your living room in atmospheric light by programming your LED to shine in dark colours. The positive impact of dimmers is not limited to private spaces; they can also add value to business premises, where the right lighting can help to create a commercial advantage.
Dimmers in hotels From the moment hotel guests enter the lobby, they expect immaculate service and perfect comfort. This includes pleasant lighting in their hotel room. Dimmed lights contribute to wellbeing in a hotel room, and it is simple for each guest to adjust the lighting to meet his or her individual needs and preferences.

Dimmers in restaurants In restaurants and bars, dimmers create the right lighting mood for guests. At the same time, bright lighting is required for laying tables and making preparations at the bar and buffet.
Dimmers in shops In sales environments, optimal illumination of presentation areas and products is essential. Whenever changes are made to the shop concept, dimmers make it easy to adapt the lighting concept to a new product presentation.

Save up to 30% energy on lighting
Requirement I want to maintain the same light intensity on my site. Solution Get the automatic DIM LC 300 UNI 230V lighting intensity controller, and you will no longer need to keep checking if your employees are switching off the lights. How to do it? Connect the product to your existing Push-button (you don't need to cut anything). It will enable you to control brightness or to switch to an automatic mode. How much will you save? A 40W lamp switched on for 8 hours for 200 days per year will equal 64KWh; and therefore ten of these lamps in a single office will equal 640kWh. If you use an automatic lighting intensity controller, the intensity of the light will remain exactly where you set it. So if the sunshine is illuminating a room with high intensity, the lamp will automatically lower its brightness. This will enable you to save up to 50% of costs.

Performances and Features
DIM LC 300 UNI 230V
Supply voltage L
Thyristor Supply voltage
indicator Light source type
selection Automated reg. luminance adjustment
Supply voltage N

Comfort Functions

Output Output indication

L
LV B
IN IN NT N

T 2.5 A recommended upstream protection
load

Automatic fade and luminance setting
Min. luminance adjustment
Terminals for connecting sensor Controlling input

Time Relays

DIM 300 UNI 230V

L

T 2.5 A

ballast protection recommended

A1 V

Supply voltage L

A2 T N

Supply voltage indication Light source type selection

Minimal luminance setting

Supply voltage N

Output Output indication
Controlling input
19

Comfort Functions
Time Relays
Pulsar T+

Modular DIN-rail devices

Features

Applications

· Multi-function time relay with 10 functions, 1 CO contact 16A or 3 CO contacts 8A
· Multi-voltage time relay two versions: AC/DC 12-240V (AC50-60Hz) and AC 230V (AC50-60Hz)
· Assymetrical time relay with 2 functions and multivoltage AC/DC 12-240V (AC50-60Hz)
· Only 4 references cover the complete range · In the case of the multi-function relay, the function itself is also user select-
able, bringing impulse switch function as default (factory setting) · Compact version of 3 CO contacts 10 functions time relay in only 1 module! · The loss-proof safety terminals are equipped with Pozidriv screws and have
IP20 protection degree.

Functions

20

Asymetrical cycle time relay

Conditioning of incoming source to exact predictable output.

Using for warning illumination on the road, flashers, cyclers, often switched systems

Standards / Marking
EN 61812-1, EN 61010-1

Multifunction relays

10 functions:

- Five time functions controlled via supply voltage

Wiring

- Four time functions controlled via control input
- One function of latching relay

1 COM
A1

16 18

3 COM
A1

16 18 26 28 36 38

It is used for regular room ventilation,

cyclic dehumidification, light control,

S A2

15

S A2

15

25

35

circulating pumps, noon signs, etc.
Loads type

M
cos  0.95

Product: PLT+MF230V16A1CO(1)

PLT+MFUNI16A1CO

M
PcLoTs +0A.95SUNI16A1CcOos





0.9H5AL230V

M

HAL230V

Type of load

cos  0.95

M

cos  0.95

cos co0s.950.95

AC1

mat. contacts coHnAtLa2c3t0V16A

AgNiH,AL2302V50HVHAA/LL212H363A00ALVV230V

MMcoMs 



cos 0c.9o5s 

 0.95  0.95

MM

MM

cos  0.95

AC5a

HAL230V

M HAL230V HAL230V

AC5a cos  0.95

cos  0.95

HAL230MV

AC2

AC3

uncompensated compensated

AC5b

AC6a

AC7b

HAL230V

HAL230V

250HHVAHAL/AL2H2L5332AA003LVV02HV3A0VL230V250VH/AH3L2AA3L02HV3A0VL230V2(3609V0V/ A3)A

x

800W

x

250V / 3A

HAL230V

HAL230V

HAL230V

Type of load

mat. contacts AgNi, contact 16A

AC13 250V / 6A

AC14 250V / 6A

Product: PLT+MFUNI8A3CO

AC15 250V / 6A

cos  0.95
cosDC10.95

M

M
cos  0.95

DC3

24V / 16A HAL230V HAL230V

24V / 6A HAL2H3A0LV230V

M
cos  0.95

M DC5 24V c/o4sA 0.95
HAL230V
cos  0.9H5AL230V

coDs CM102.95 24V / 16A
HAL230V

M

HAL230V

M DC13
24V / 2A
HAL230V

Type of load

cos  0.95

M

cos  0.95

cos co0s.950.95

AC1

mat. contacts coHnAtLa2c3t0V8A

AgNiH,AL2302V50HHVAAL/L22H833AA00LVV230V

Type of load

AC13

mat. contacts AgNi,

x

contact 8A

MMcoMs 



cos 0c.9o5s 

 0.95  0.95

MM

MM

cos  0.95

AC5a

HAL230V

M HAL230V HAL230V

AC5a cos  0.95

cos  0.95

HAL230MV

AC2

AC3

uncompensated compensated

AC5b

AC6a

AC7b

250HHVAHAL/AL2H2L3332AA003LVV02HV3A0HVLA2L3203V20V50VH/A3HL22AA3L02HV3A0HVLA2L3203V203V(304V5/V1A.5) A

x

300W

x

250V / 1A

HAL230V

HAL230V

HAL230V

AC14 250V / 3A

AC15 250V / 3A

cos  0.95
cosDC10.95 24V / 8A
HAL230V HAL230V

M

M
cos  0.95

DC3

24V / 3A HAL2H3A0LV230V

M DC5 24V / 2A
HAL230V

coDs C102.95
24V / 8A
HAL230V

M DC13
24V / 2A
HAL230V

(1) Only at 230VAC

cos  0.95
AC12 250V / 10A
HAL230V
DC14 24V / 2A
cos  0.95
AC12 250V / 1A
HAL230V
DC14 x

M
HAL230V
M
HAL230V

Comfort Functions

Pulsar T+ Time Relays

Nom. Cont. Contact Funct. Coil Coil Voltage Timing No. of

current nr combin. nr voltage voltage tolerance scale mod.

AC

DC

Cat. No.

Ref. No. Pack.

16A 1 1 COM a ... j(1) 230V

-

50-60Hz

-15% ... 0.1s ... 1 PLT+MF230V16A1CO 685993 1 +10% 10 days

16A 1 1 COM a ... j(1) 12-240V 12-240V -15% ... 0.1s ... 1 PLT+MFUNI16A1CO 685994 1

50-60Hz

+10% 10 days

Time Relays

16A 1 1 COM k, l 12-240V 12-240V -15% ... 0.1s ... 1 PLT+ASUNI16A1CO 685996 1

50-60Hz

+10% 100 days

8A 3 3 COM a ... j(1) 12-240V 12-240V -15% ... 0.1s ... 1 PLT+MFUNI8A3CO 685995 1

50-60Hz

+10% 10 days

U

(1)

FacUtory U U U

stetting: t
t t

i

t t
t t

Ut

t

U UUU

t t
t t

tt tt
tt tt

S

ati-mOenddeelalSSSSSayyis(PcoowmeprlttttteOten.)CWonhteancttttttthseRinreptuutrvnotltoatgheeUir isshaeplfpsliteadt,etiwmhinegndienlpauyttvboelgtaingse.

Relay contacts R change state after U is removed. Trigger switch is not

ubWs-heOedfnfintditmehSSSSlieasydfueWnlachyteiiosnnci.onmpttttuptlevtoel,tcaognetUattttctiss

applied, relay return to shelf

contacts R change state immediately and timing cycle begins. state. When input voltage U is removed, contacts will also return

Ut

tt

U U UU

tt tt
tt tt

tt tt
tt tt

t t
t t

t t
t t

to their shSelfstate. Triggter switch is tnot used in this function.

crne-oRlateyupsceeodantSSSStinaCctythscislRefuc(Snhtttttcaatnirogtenin.ttttsgtaOteffftttt)oWr ttttthimene

input delay

voltage U is t. This cycle

applied, time delay t begins. When time delay t is complete, will repeat until input voltage U is removed. Trigger switch is

U tt t t t t

U U UU

tt tt
tt tt

tt tt
tt tt

t t
t t

t t
t t

d-RepeaSSt Cycle

tt (Starting

t On)

t When

input

voltage

U

is

applied,

relay

contacts

R

change

state

immediately

and

time

delay t beSgins. When time delay t is complete, contacts return to their shelf state for time delay t. This cycle will repeat

until inpuSt voltage U is removed. Trigger switch is not used in this function.

S

S S SSS
UUUSSS S U
15-1U8 15-1U8
111555---111888USSSS S

tt t t t t

t

t

t

t

t

t

t

t

t

t

t ttt

t ttt

t t t2 t1 t t2 t1 t t t2 t1 t t2 t1

t t2 t1 t2 t1

t tt

t

tt22ttt t

t1 tt1

t

ttt22ttt t

t1 t1

ecstRhth-raeaOetndtefuge.freIldfansetyUUUUUttrlobaiagetytgehge(.ieSnrWitttttsrsBhwsarPPPPPehgeiUUUUUtneaLLLLLacSSSSSlPPPPithfkEEEEEnrUUUUs)i,SgtLLLLaIangSSSSnistepde====ruc.rtttttslt0000eowv....ls5555PPPPPaoiUUUUUetysssslLLLLLdctSSSSScahEEEEEbogSeneftiosUarcoemtpsteuiRmnstereedbmd,edeaaeliapnlaypiylntietitsdbhececogiorimnnetsnpi.nelWeurtgoehiuz,eetsnhdlyed.sneWtlatahtiymeet.neIifstiisrnciopgregmuseteprvtlsoe.wltWteait,hgcceehonUnSttiarissicgrctgesleomRrsoesrvedwet,iudrtecr, nrlhaetySloaciytsohcnoeotpinaretcsnathcesetdRlsf,

f-SingUle SShot UponPaUpLpSli=ca0t.i5ons of input voltage U, the relay is ready to accept trigger signal S. Upon application of

tigtghr-inSeg1111ogi5555tnre----re1111girgdUUUU8888SSSSSlsge.iTegSShrnhesaiolrgetSnl.ttttTaa2222UlryapSrioe,lttisnnhetttt1111aegtsprEpebdllyiagcttttay2222aeptci(pooNtlnnyottttti1111noangfc-tRttttttshh2222eeeRtrtttirrrgiiagggnggeeserfrraessbriwgalenint)acdUlhtSphS,oetwnhpheareeprnsepeltlaithcyetaictmrioeonelnattyaobcifsteisnngiRponutstter.anDvnoeusrlrtfgieanizrggeeatdniU.md, etthh-oeeurpter,letashyeeitsttrriimegageedtry

signal S is
to accept begins. At

the15e-n1d8 of the ptr2eset tt1imt e tt,2the rte1latyt2contacts R return to their normal condition unless the trigger switch S is opened

and closed prior to time out t (before preset time elapses). Continuous cycling of the trigger switch S at a rate faster

t

t

than the preset time will cause the relay contacts R to remain closed. If input voltage U is removed, relay contacts R

ttt t
t

USSSS S

t

tttt t

tt

ttt t

t

tttt t

tttttt

t t tt

return toStheir shelf state.
h-On/Off delay Intput votltage tU mtust be applied continuously. When trigger switch S is closed, time delay t begins.
When time delay is complete, relay contacts R change state and remain transferred until trigger switch S is opened.

If input voltage U is removed, relay contacts R return to their shelf state.

ttttt

USS

S S

t

tt

tt t

tt t t

i-LatchinSg relay Input voltage U must be applied continuously. Output changes state with every trigger switch S
closure. If input voltage U is removed, relay contacts R return to their shelf state.

t

ttttt t
t 222 ttt111 2 t1 2 t1

SUUUS U
UUU U
11115555----1111UU8888SSSSS 15-18
U

ttt

t PULSE
PPUULLSSEE

ttt

PULSE PPUULLSSEE

t

t t

PULSPPPEUUULLLSSS PULSPEULS

====tt0000....5555PPUUssssLLSSEE

PULS = 0.5 s

t PULSE

t PULSE

tttt222 PtttU1112LS =ttt02221.5 s tttt1112 ttt2221 t2 t1 t2 t1 t2
t2 t1 t2 t1 t2

jt-imPuelsdeelgaUyent.eProawtoerr

Upon must

application be removed

of input voltage U, a single output pulse of 0.5 and reapplied to repeat pulse. Trigger switch is

seconds not used

is delivered to relay in this function.

after

t PULSE

t PULSE

PULS = 0.5 s

ASSYMETRICAL CYCLER RELAY

k-CyclUer beginning with pulse

S 15-18

t2 t1 t2 t1 t2

l-Cycler beginning with pause

S

2 t1

15-18

t2 t1 t2 t1 t2

21

Modular DIN-rail devices

Comfort Functions

Technical data Time Relays
PLT+MFUNI16A1CO

PLT+MF230V16A1CO Technical data

PLT+MFUNI8A3C

PLT+ASUNI16A1CO

Number of functions
Supply Supply voltage Consumption Supply voltage tolerance Supply indication Time ranges Time setting Time deviation Repeat accuracy Temperature coefficient

AC/DC12-240V (AC50-60Hz) AC0.7-3VA/DC 0.5-1.7W

10 (a....j)

A1-A2

AC 230V / 50 - 60Hz

AC/DC12-240V (AC50-60Hz)

AC max. 12VA / 1.3W

AC max. 12VA/1.9W

-15%; +10%

green LED

0.1 s - 10 days

rotary switch and potentiometer

5% mechanical setting

0.2% set value stability

0.01% °C, at =20°C

2: k, l. (second func. is chosen by connecting S-A1)
AC/DC12-240V (AC50-60Hz) AC0.7-3VA/DC 0.5-1.7W

Output

Changeover contacts Rated current Breaking capacity Inrush current Switching voltage Min. breaking capacity DC Output indication Mechanical life Electrical life (AC1)

1x changeover 16A / AC1
4000VA/AC1;384W/DC 30 A/<3s

3x changeover 8A/ AC1
2000VA/AC1;192W/DC 10 A/<3s
250VAC1/ 24VDC 500 mW
multifunction red LED 3x10000000 0.7x100000

Controlling

1x changeover 16A / AC1
4000VA/AC1;384W/DC 30 A/<3s

Consumption of input

AC 0.025-0.2 VA/ DC 0.1 - 0.7W (UNI), AC 0.53 VA (AC 230V)

-

Load between S-A2

YES(1)

-

NO

Glow tubes connections

230V - Yes / UNI - No

-

Max. amount of glow lamps

UNI - glow lamps cannot connected/NO

-

connected to controlling input

230V - max. 20 pcs (measured with glow lamp 0.68mA/230VAC)

-

Control. terminals

A1-S

-

Impulse length

min. 25ms / max. unlimited

-

Other information

Reset time

max. 150ms

Operating temperature

-20.. +55°C

Storage temperature

-30.. +70°C

Electrical strength

4kV (supply-output)

Operating position

any

Mounting

DIN-rail EN 60715

Protection degree

IP40 from front panel; IP20 terminals

Overvoltage cathegory

III.

Pollution degree

2

Max. cable size

max.1x2.5; max. 2x1.5/with cavern max. 1x2.5

Dimensions

90 x 17.6 x 64 mm

Weight (g)

64

62

89

65

Standards

EN 61812-1, EN 61010-1

(1) Through clamps S-A2 can be connect the loading parallel (for example contactor or other units) - without damage of right operation.

+

A1

Un

S A2

load

16 18 15

Un

+

­

A1 S A2

15 16 18

22

Dimmers

Comfort Functions

Dimmers
Today we encounter all kinds of different light sources, which makes it relatively hard for the average person to keep track of all of them. So in the following section, we will try to explain exactly what light sources you will find on the market, and how to control and/or dim them.

By dimming, you can save up to 20% of the electricity cost of lighting. Dimming also enables you to create a magical atmosphere - perfect for a party, for reading or for watching a movie. Individual light sources vary, depending on how they work - and we assign a `load' to each of them. Load information is important when selecting the right dimmer for your light.

TYPES OF LAMPS
R
Resistive

R ­ You mainly encounter resistance load with the ordinary lamp. The entire process works on the principle of heating a thin, usually tungsten filament, with an electric current running through it.

L
Inductive

L ­ This is an inductive load mainly characteristic for low-voltage (12-24V) halogen lamps, which are controlled by a wound transformer, whose principle is the passage of voltage through the coil. By decreasing the voltage at the input, we in turn also change the value of the voltage at the output, which enables dimming.

C
Capacitive

C ­ This is a capacity load mainly characteristic for energy-saving lamps, fluorescent or halogen lamps controlled by an electronic transformer. The principle is based on electrical ballast, which brightens or darkens the lamp. A dimmable transformer is used to dim.

1-10V

1-10V - This type of regulation is conditional to so-called dimmable electrical ballast with input for 1-10V. Consequently, at this input, the product is connected with the output 1-10V (RFDA-71B, LBC3-22M), which enables brightness control within this range. This mostly concerns dimming tube fluorescent lamps.

Dimmers and type of lamps

LED
Light-Emitting Diode

LED ­ A Light-Emitting Diode (LED) is an electronic semiconductor component, which radiates a visible light. In the last few years, they have replaced the lamps in automobiles, streetlights and home appliances, and their popularity as active household illumination is constantly growing. The basis of the LED is the P-N junction. The actual LED chip is often connected with a cooler for efficient removal of waste heat away from the chip, and is covered by an epoxy capsule. This design makes LEDs highly mechanically resistant. It is even more effective than a compact fluorescent lamp - and is up to 15x more efficient than a classic incandescent lamp.

ESL
Energy Saving Lamp

ESL ­ Energy saving lamp, often called a compact fluorescent lamp. In its design it is a capacity load, but for better separability of this type of light source, a special designation was created for it. The principle is a glass tube with heating electrodes filled with mercury vapors, in which the discharge occurs. This falls upon the walls of the tube covered with a luminophore - and the lamp illuminates. Disadvantages of this lamp are its sensitivity to frequent switching and the luminous flux that decreases over time.

R

L

C ESL

LED

Standard light bulbs, halogen lamps Low voltage lamps 12-24V wound transformers Low voltage lamps 12-24V electronic transformers Efficient dimmable fluorescent lamps Category 1 Mostly "multiple LED" illumination sources power provided by LINEAR source limiting current (sharper dimming), lower price Category 2 Sources that have 1-3 power LEDs, power provided by SWITCHING the source regulating brightness based on the input voltage (smoother dimming), higher price GU10 have higher body Category 3 LED with DC and current regulation. Designed for dimming LED chips, LED strips, RGB LED

Order codes

EAN code

685997 DIM500RL230V

Short press ON/OFF,

5413656859970 X

X

pressing and holding dims, 500VA

685998 DIM300UNI230V

Dimmer for LED lamps and dimmable efficient fluorescent lamps,

5413656859987 X

X

X

X

X

X

potentiometer brightness setting

685999 DIMLC300UNI230V

Dimmer maintaining and light intensity in Lx, 5413656859994 X

X

X

X

X

X

including SKS photo-sensor

23

Comfort Functions
DIN-rail dimmers
DIM

Modular DIN-rail devices

Applications
DIM dimmers are designed to adjust light intensity to your needs. They are particularly intended for the residential and tertiary sectors, for example to light conference rooms, cinemas, restaurants and shops. Nowadays, there are a lot of lighting sources and of course, for a layman, it is really hard to understand which one is the best. Dimming can save up to 20% of your energy bills. Moreover, dimming can create the right atmosphere for party, reading a book or watching a movie...
Marking

Features
- Low version dimmer only valid for resistive and halogen lamps - Universal dimmer optimised for LED and CFL lighting, a new universal
dimmers perfectly align to any DIN-rail installation. - Thanks to the low width of 18mm only, the DIN dimmers are particularly
suitable for retrofitting. - The universal DIN-dimmers are the perfect choice for all buildings which
demand individual and efficient lighting such as shops, restaurants or public areas. - Universal dimmer with automatic lighting level control. Ideal to mantain the same light intensity in any site.
Functions
In the past, many different lamps required many different specific dimmers. So changing lamps often led to the situation that the installed dimmer could not control the new lamp without disturbances. Your customers thus faced humming and flickering lighting - and you were forced to choose the right dimmer from a more and more complicated offer.
Industrial Solutions has developed a universal dimmer module you can easily upgrade an installed push-button to future-proof dimmer. The dimmer is optimised to control LED and reliable dims other loads as well. Installed in a switchboard, on a DIN-rail, they can be controlled by several push-buttons.
Wiring

A1

R, L

V

T A2
RL dimmer

A1
V T A2
Universal dimmer

Performance
Load

colsamp0.,95 halogen light
HAL230V

M
low-voltage el. bulbs 12-24V wound trans.

low-voltage el. bulbs 12-24V el. transformers

HAL230V

R

L

C

DIM 500 RL 230V

·

·

x

DIM 300 UNI 230V

·

·

·

DIM LC 300 UNI 230V

·

·

·

LED bulbs
230V AC dimmable
x
· ·

saving fluorescent
lamps
dimmable
x
· ·

BL

IN

IN

V

TN
Universal dimmer with automatic lighting level control

switching management

incline edge
· · ·

descending edge
x
· ·

24

Comfort Functions

DIM DIN-rail dimmers

Dimmed Type Output load of lamps

RL dimmer

R: 10...500VA R, L

2A

L: 10...250VA

Control by

Nominal Voltage No.

voltage tolerance of

AC

mod.

Cat. No.

Ref. No. Pack

Push-button 230V/ -15%..+10% 1 DIM500RL230V 685997 1 50Hz

Universal dimmer

300W

R, L, C, 2xMOSFET Push-Button

(cos=1)(1) LED, ESL

230V -15%..+10% 1 DIM300UNI230V 685998 1 /50Hz

Universal dimmer with automatic lighting level control

300W

R, L, C, 2xMOSFET Push-button & 230V/ -15%+15%

(cos=1)(1) LED, ESL

Light sensitive 50Hz-60Hz

photocell

1 DIMLC300UNI230V 685999 1

Dimmers

(1) D ue to a large number of light source types, the maximum load depends on the internal construction of dimmable LEDs and ESL bulbs and their power factor cos . The power factor of dimmable LEDs and ESL bulbs ranges from cos  = 0.95 to 0.4. An approximate value of maximum load may be obtained by multiplying the load capacity of the dimmer by the power factor of the connected light source.

Supply A1-A2
Supply A1-A2
Output brigOhutntpesust brightness Controlling Conctoronltlaincgt T
contLaEcDt T<0.5s LED <0.5s

<0.5s >0.5s <0.5s >0.5s

<0.5s >0.5s

<0.5s

<0.5s >0.5s

<0.5s

Supply A1-A2
Supply A1-A2T VT
R, L, C, LEDV R, L,SmCu,ipnLpElDy
min V ESVL
OmuitnEpSuLt brighmtniness

>0.5s >0.5s
A1-A2

<0.5s <0.5s <0.5s <0.5s

>0.5s

<0.5s

>0.5s

<0.5s

max

max

max

max

Controlling contact Un LUEDnT
BT
SupplymAa1x-.AB2 mrega.x. reg. T V
R, LL, ECD, LED LLmEEDDinUn
LED UnV ESL
min

T <0.5s <0.5s >0.5s
0.5s - 3s
0.5s - 3s

t

t

>0.5s t <0.5s t

<0.5s >0.5s >3s 3>s3s 3s

<0.5s

>0.5s

max

max

<0.5s <0.5s <0.5s
<0.5s

Un 0.5s - 3s
T
B

max. reg.

t

t

LED LED Un

>3s

<0.5s

3s

RL dimmer -short press for switch on/off the lamp, longer press (> 0.5 s) for fluent illumination regulation -w hen a device is de-energized, the brightness level is stored in its memory. When the device is energized again, a
light is off. You can switch this light on by pressing a button. The light then switches on in the brightness level which is stored in its memory.
Universal dimmer Controlling -short button press (<0.5s) turns the light off or on -long press (>0.5s) enables slight regulation of light intensity -setting of minimal luminance is possible only during decreasing of luminance by long button press -setting of minimal luminance by saving fluorescent lamps serves for harmonizing of lowest light intensity
prior its unprompted switching off Luminance setting R, L, C, LED - if the light is turned off, short press (<0.5s) switches the light onto last set luminance level ESL - if the light is turned off, short press increases the luminance onto maximal level (saving fluorescent lamps fires up) and then luminance decreases onto set level. Notice -it is not possible to dim saving fluorescent lamps without marking: dimmable -an incorrect setting of light source has effect only on dimming range, it means neither dimmer or load get damaged -T he maximum number of dimmable light sources depends on their internal construction
Universal dimmer with automatic lighting level control T-button control -pressing button shortly (<0.5s) always turns of lamp -pressing button longer (0.5... 3s) turns on lamp in automatic regulation mode -pressing button long (>3s) turns on lamp to full illumination - ,,cleaner" mode -after turning on the power supply, the dimmer is always turned off Thyristor B serves to block automatic regulation (lamp turns off) WARNING! The lamp may be turned on in "cleaner" mode even while blocked. After ending block mode, the lamp remains off. Control elements on the instrument panel -load switch ­ has 2 positions for each type of load that differ in their regulation curves
(sets the best position for the connected load) -the lamp turns off (if previously on) whenever the switch settings are changed -potentiometer setting of minimal luminance -potentiometer setting of desired lighting level during automatic regulation -the potentiometer status is stored in short-term memory whenever a change occurs - a green LED flashes
(approx. 3s) while storing -both lighting levels are storing in EEPROM memory during a power supply failure - LED meanwhile briefly turns off WARNING! -both lighting levels must be reset when switching Load type -both lighting levels may only be set in automatic mode while the lamp is on -potentiometer setting of lighting level fade speed - only available in automatic regulation mode -determines the reaction time to changes in surrounding lighting level

25

Modular DIN-rail devices

Comfort Functions

Technical data dimmers

DIM500RL230V

Supply

DIM300UNI230V

DIMLC300UNI230V

Supply terminals Supply voltage Supply voltage tolerance Consumption Supply indication

max. 5 VA

A1-A2 AC 230V / 50Hz
-15%; +10%

max. 1.5 VA/0.7W Green LED

Controlling

L-N AC 230V / 50-60Hz
-15%; +10% max. 1.6 VA/0.8W

Button - control. terminals Control voltage Control input power Control impulse length Glow tubes connection Maximum number of connected glow lamps the control input Blocking input - terminals Control voltage Consumption Connect glow-lamps (terminals L - B) Impulse length

T-A1

AC 230V

max. 1.5VA

AC 0.3-0.6VA

min. 80ms / max. unlimited

YES

max. 15 pcs (measured with glow lamp 0.68mA/230V AC)

-

Output

L-T
max. 0.6VA
230V - max.count 50ks (measured with glow 0.68mA/230V AC)
L - B AC 230V max. 0.1VA
NO min. 80ms / max. unlimited

Output type Output status indication Load capability

2A R: 10 - 500VA; L: 10 - 250VA
Other data

red LED

2 x MOSFET 300W (at cos  = 1)(1)

Operating temperature Storing temperature Operating position Mounting Protection degree Overvoltage category Pollution level Max. cable size Dimensions Weight (g) Applying standards

-20... +55°C -30... +70°C
58

-20.. +35°C -20.. +60°C any DIN-rail EN 60715 IP40 from front panel, IP10 terminals III. 2 max. 2x2.5; max. 1x4 s/with carven max. 1x2.5; max. 2x1.5 90 x 17.6 x 64mm
57 EN 60669-2-1; EN 61010-1

vertical

(1) Due to a large number of light source types, the maximum load depends on the internal construction of dimmable LEDs and ESL bulbs and their power factor cos. The power factor of dimmable LEDs and ESL bulbs ranges from cos = 0.95 to 0.4. An approximate value of maximum load may be obtained by multiplying the load capacity of the dimmer by the power factor of the connected light source.

26

Comfort Functions
New electromechanical time switches Complete range of possibilities
· 1, 2, 2.5 modules · With and without battery · Daily (Grey trippers), weekly (Yellow trippers) timers · Shortest switch time: 15 minutes or 30 minutes models · Normally Open and Changeover contacts
27

Modular DIN-rail devices

Comfort Functions
New SIMPLE digital time and astronomical switches
GLX+Q 30 Time switch
The perfect combination of the precision of digital time switch and the simplicity of the electromechanical one. · Display clarity, simplicity in the 3 keys · Replaceable backup battery through the rear cover on the back
Use · Gardens lighting, courtyards, alleys, ... · Opening gates, doors, ...
Electric utilities management throughout the day
· Desired program setting with simple ON/OFF of the virtual trippers lasting 30 minutes each
· All performed programming is immediately viewable on the display · 1 program for everyday or 7 programs, one for each day of the week
(weekly version of the instrument) · Automatic summer/winter time change · The instrument is supplied with already set time and date
Astronomical switch
· Automatic programming of switching on (at sunset) and switching off (at sunrise) · Possibility of night switching off with OFF virtual trippers · Automatic summer/winter time change · The instrument is supplied with already set time and date
Use · Shops, shop windows, ... · Roads, parks, fountains, ... · Illuminated signs, monuments, ...
28

Comfort Functions
New digital time and astronomical switches GLX+Q 1
Digital time switches 2 DIN-modules to manage electrical utilities in time with the maximum precision. The available models permit to make daily, weekly, monthly and yearly programs with 1 of 2 channels. Electronic time switch that combines the functionality of astronomical (channel 2) and digital switch (channel 1)
Digital time switch 3 DIN-modules with add on power contacts module and software to program remotely or through IR interface
New light sensitive switches
CHARATERISTICS · Compact form of the cover · Adjusting method of the intervention
threshold (which occurs via trimmer without the need to open the device)
29

Comfort Functions
Analogue time switches
Classic Plus

Modular DIN-rail devices

Applications
Going from the pre-programmed switching of lighting (car park, adver tising signs, public roads, etc.) over pre-programmed switching of heating equipment (home and work-environment , waterheating, etc.), to the preprogrammed switching of motors for pumps and fans and even to presence simulation.

Features
Going from the pre-programmed switching of lighting (car park, advertising signs, public roads, etc.) over pre-programmed switching of heating equipment (home and work-environment , waterheating, etc.), to the preprogrammed switching of motors for pumps and fans and even to presence simulation.
Functions
Pre-programmed switching of all kinds of electrical devices
Standards / Marking
VDE 0633, BS EN 60730-1, BS EN 60730-2-7

Performance
Contact Fix on, Fix off, Auto switch Rated switching capacity - Resistive load Connectable Loads - Incandescent - Fluorescent (neon) - Low voltage halogen - Halogen (230V) - Low consumption (CFL) - Led Shortest switching time day-program Shortest switching time week-program Screws Terminal capacity: min
max Clockwork Operating voltage Own consumption at 230V Running reserve Battery charging time Operating temperature range Accuracy Sealable

Plastic switches

NET SYNCHRONISED

QUARTZ SYNCHRONISED

1 module

2 modules

2.5 modules

1 module

2 modules

2.5 modules

Voltage free NO Voltage free CO Voltage free CO Voltage free NO Voltage free CO Voltage free CO

yes

yes

yes

yes

yes

yes

16A/250V

16A/250V

16A/250V

16A/250V

16A/250V

16A/250V

2500W 1200VA 2000VA 2500W 900VA - 1000VA 100VA 15 min.
Pozidriv1
1mm2 4mm2

3000W 1200VA 2000VA 3000W 900VA - 1000VA 1000VA 30 min.
Pozidriv1
1mm2 4mm2

3000W 1200VA 2000VA 3000W 900VA - 1000VA 1000VA 15 min.
Pozidriv1
1mm2 4mm2

2500W 1200VA 2000VA 2500W 900VA - 1000VA 100VA 15 min.
Pozidriv1
1mm2 4mm2

3000W 1200VA 2000VA 3000W 900VA - 1000VA 1000VA 30 min. 210 min. Pozidriv1 1mm2 4mm2

3000W 1200VA 2000VA 3000W 900VA - 1000VA 1000VA 15 min. 120 min. Pozidriv1 1mm2 4mm2

230 V AC(-15%...+10%) 230 V AC(-15%...+10%) 230 V AC(-15%...+10%) 230 V AC(-15%...+10%) 230 V AC(-15%...+10%) 230 V AC(-15%...+10%)

0.5W

0.5W

0.5W

0.5W

0.5W

0.5W

-

-

-

150h

150h

150h

-

-

-

120h

96h

96h

-10 ºC ... +50ºC -10 ºC ... +50ºC -10 ºC ... +50ºC -10 ºC ... +50ºC -10 ºC ... +50ºC -10 ºC ... +50ºC

±1s/24h at 25°C ±1s/24h at 25°C ±1s/24h at 25°C ±1s/24h at 25°C ±1s/24h at 25°C ±1s/24h at 25°C

yes

yes

yes

yes

yes

yes

30

Classic Plus

Comfort Functions

NET SYNCHRONISED Day programmable

Classic Plus - Analogue time switches

Program No. of Nominal channels Current

Running Shortest reserve switch
time

Operating Voltage: 230 V AC(-15%...+10%)

1x24x4 1NO 16A/250Vac

-

1x24x2 1CO 16A/250Vac

-

1x24x4 1CO 16A/250Vac

-

15min. 30min. 15min.

Fix on/off auto
yes yes yes

No. of mod.

Cat. No.

Ref. No. Pack.

1 CLS+S 15 1NA 16A 1M D 687436 1 2 CLS+S 30 1COM 16A 2M D 687438 1 2.5 CLS+S 15 1COM 16A 2.5M D 687441 1

QUARTZ SYNCHRONISED Day programmable

1NO

1CO

Operating Voltage: 230 V AC(-15%...+10%) 1x24x4 1NO 16A/250Vac 150h 1x24x2 1CO 16A/250Vac 150h 1x24x4 1CO 16A/250Vac 150h

15min. 30min. 15min.

yes

1 CLS+Q 15 1NA 16A 1M D 687437 1

yes

2 CLS+Q 30 1COM 16A 2M D 687439 1

yes 2.5 CLS+Q 15 1COM 16A 2.5M D 687442 1

QUARTZ SYNCHRONISED Week programmable

1CO

Operating Voltage: 230 V AC(-15%...+10%)

7x24/3.5 1CO 16A/250Vac 150h 210min. yes

2 CLS+Q 210 1COM 16A 2M W 687440 1

7x24/2 1CO 16A/250Vac 150h 120min. yes 2.5 CLS+Q 120 1COM 16A 2.5M W 687443 1

1CO

31

Comfort Functions
Digital Time Switches
Galax Plus

Modular DIN-rail devices

Applications
Going from the pre-programmed switching of lighting (car park, advertising signs, public roads, etc.) over pre-programmed switching of heating equipment (home and work environment, water heating, etc.), to the preprogrammed switching of motors for pumps and fans and even to random presence simulation.
Standards
BS EN-60730-1, BS EN-60730-2-7, VDE 0633

Features
Very easy programming, with quasi unlimited possibilities compared to the analogue time switches. Devices with daily, weekly and yearly event programming possibilities are available in 1, 2 up to 8 channel execution. All devices have a shortest switching time of one minute. On all devices, the summer/ winter time change is fully automatic. Devices with block-programming,
Functions
Pre-programmed switching of all kinds of electrical devices

Performance
Contact Rated switching capacity - Resistive load Connectable Loads - Incandescent 240V - Fluorescent (neon) - Halogen (230V) Minimum switching load DC switching capacity Shortest switching time Screws Terminal capacity: Clockwork Operating voltage Own consumption at 230V Operating temperature range Accuracy Sealable

DAY/WEEK PROGRAMMABLE

1 module

2 modules

Voltage free NO

Voltage free CO

DAY/WEEK/MONTH/YEAR

DW

BUS

Voltage free CO

Voltage free NO

16A/250 VAC

16A/250 VAC

16A/250 VAC

16A/250 VAC

1500W 600W 1500W 100mA/5 VDC 16A/24 VDC 30 min
PH 1-4mm2

1500W 600W 1500W 100mA/5 VDC 16A/24 VDC 30 min
PH 1-6mm2

1500W 600W 1500W 100mA/5 VDC 16A/24 VDC 1 min
PH 1-6mm2

1500W 600W 1500W 100mA/5 VDC 16A/24 VDC 1 min
PH 1-6mm2

230V AC(-15%...+10%) 6VA (1W)
-20ºC...+50ºC ± 1 second/day at 25ºC
no

230V AC(-15%...+10%) 5.5VA (1W) -20ºC...+50ºC
± 1 second/day at 25ºC no

230V AC(-10%...+10%) 8VA (2W)
-20ºC...+50ºC ± 1 second/day at 25ºC
yes

230V AC(-15%...+10%) 7VA (2.6W) -20ºC...+50ºC
± 0.5 second/day at 25ºC yes

32

Galax Plus

Comfort Functions

Galax Plus - Digital time switches

Program No. of Switching capacity Running Shortest No. of

channels

reserve switch modules

time

Cat. No.

Ref. No. Pack.

QUARTZ SYNCHRONISED Operating Voltage: 230V AC(-15%...+10%) Day programmable 1x24x2 1CO 16A (10) at 250V AC 5 years 30 min
Astro programmable 1x24x2 1CO 16A (10) at 250V AC 5 years 30 min

2 GLX+Q 30 1COM 16A 2M D ANA 687447 1 2 GLX+Q AST30 1NA 16A 2M D ANA 687449 1

Week programmable 7x24h/0.5 1CO 16A (10) at 250V AC 5 years 30 min

2 GLX+Q 30 1COM 16A 2M W ANA 687448 1

1CO

For day/week timers - P ower supply: 230V 50/60Hz - D aily or weekly versions - S witching of the relay only in presence of
power suppply - M anual override of the relay
(temporary or permanent) - S ummer time automatic update - D ate and time already default set - B ackup battery for maintaining the date and time
without power from the mains - L ow battery signal - P assword protected lock keypad - B acklighting always on when instrument is mains
powered (auto power off for energy saving in the case of blackout) - 4 8 virtual trippers for a resolution of 30 minutes

For Astro Timers - Available programming:
- P1 fixed with possibility of night-switch ON/OFF of minimum 30 minutes - Sunrise and sunset hours are calculated according to phone prefix or geographical coordinates - Display of the sunset/sunrise times calculated by the device - Update of sunrise/sunset hours: ±120 minutes - Summertime automatic update
- Manual override of the relay (temporary or permanent) - Relay switching only with power supply - Depleted battery signaling

Galax Plus - Digital time switches

Program No. of Switching capacity Running Shortest No. of

channels

reserve switch modules

time

Cat. No.

QUARTZ SYNCHRONISED Operating Voltage: 230V AC(-15%...+10%)

Day programmable 1x24x4 1NO 16A (10) at 250V AC 4 years 30 min

1

GLX+Q 30 1NA 16A 1M D

Astro programmable 1x24x4 1NO 16A (10) at 250V AC 4 years 30 min

1

GLX+Q 30 1NA 16A 1M AST D

Ref. No. Pack.
687444 1 687446 1

Week programmable 1x24x2 1NO 16A (10) at 250V AC 4 years 30 min

1

GLX+Q 30 1NA 16A 1M W 687445 1

1NO

For day/week timers - P ower supply: 230V 50/60Hz - D aily or weekly versions - S witching of the relay only in presence of power
suppply - M anual override of the relay (temporary or
permanent) - S ummer time automatic update - B ackup battery for maintaining the date and time
without power from the mains - L ow battery signal - B acklighting always on when instrument is mains
powered (auto power off for energy saving in the case of blackout) - 4 8 virtual trippers for a resolution of 30 minutes

For Astro Timers - Available programming:
- P1 fixed with possibility of night-switch ON/OFF of minimum 30 minutes - Sunrise and sunset hours are calculated according to phone prefix or geographical coordinates - Display of the sunset/sunrise times calculated by the device - Update of sunrise/sunset hours: ±120 minutes - Summertime automatic update - Manual override of the relay (temporary or permanent) - Relay switching only with power supply - Depleted battery signaling

33

Modular DIN-rail devices

Comfort Functions

Galax Plus - Digital time switches

Program No. of Switching capacity Running Shortest No. of

channels

reserve switch modules

time

Cat. No.

QUARTZ SYNCHRONISED Operating Voltage: 230V AC(-10%...+10%) With no IR interface 7x24x60 1CO 16A (10) at 250V AC 3 years 7x24x60 2CO 16A (10) at 250V AC 3 years

1 min 1 min

2

GLX+Q 1 1COM 16A 2M DW

2

GLX+Q 1 2COM 16A 2M DW

Ref. No. Pack.
687450 1 687451 1

With IR 7x24x60 1CO 16A (10) at 250V AC 3 years 1 min interface 7x24x60 2CO 16A (10) at 250V AC 3 years 1 min

2 GLX+Q 1 1COM 16A 2M DW IR 687452 1 2 GLX+Q 1 2COM 16A 2M DW IR 687453 1

ASTRO 7x24x60 7x24x60
remote Infrared control

1CO 16A (10) at 250V AC 3 years 2CO 16A (10) at 250V AC 3 years
- 2x1.5V (AAA type batteries)

1 min 1 min
-

2 GLX+Q 1 1COM 16A 2M AST IR 687454 1 2 GLX+Q 1 2COM 16A 2M AST IR 687455 1

-

GLX+ IR

687456 1

1CO

2CO

For day/week timers - Power supply: 230V 50/60Hz - Version: 1 or 2 channels - S witching of the relay only in presence of power
suppply
- M anual override of the relay (temporary or permanent)
- Program: ON, OFF, CYCLE, PULSE (1...9 seconds) HOLIDAY, RANDOM - M aximum storable programs for each channel:
- 30 events (on, off, cycle, pulse) - 4 holiday periods (period = more consecutive days) - 20 holiday days (single days) - Integrated infrared interface (only available in GLX+Q DW IR) - P assword protected lock keypad - D isplay automaticaly shuts-off after 3 minutes of inactivity of the keyboard

For Astro Timers - Available programming:
- P1 fixed and not modifiable - Only for GLX Q 2COM: 6 programs on output 1 - Maximum holiday events for each channel: 4 periods + 20 days - Display of the sunset/sunrise times calculated by the device - Update of sunrise/sunset hours: ±120 minutes - Summertime automatic update - Manual override of the relay (temporary or permanent) - Relay switching only with power supply - Depleted battery signaling - Integrated infrared interface

For GLX+IR - Charge reserve for battery replacement: 2 minutes - Viewing with display LCD (non-backlit) - Text guide
- Available languages: English/Italian/Spanish/French/German
- Maximum number of programs that can be stored: 126

Galax Plus - Digital time switches

Program No. of Switching capacity Running Shortest No. of

channels

reserve switch modules

time

Cat. No.

QUARTZ SYNCHRONISED Operating Voltage: 230V AC(-10%...+10%) 365x24x60 1CO 16A (10) at 250V AC 5 years 1 min

3

GLX+Q 1 1COM 16A 3M Y BUS

Ref. No. Pack. 687464 1

Operating Voltage: 230V AC (-15%...+10%)

-

4CO 8A (5) at 250V AC

-

-

4

GLX+Q 4COM 8A 4M BUS 687466 1

Operating Voltage: 12V DC(-20%...+20%)

GEOBUS -

-

-

-

-

-

GLX+ GEO BUS

687465 1

For day/week/month/year timers

For Receiver:

GLX+ GEO BUS

- Time programming (D/W/M/Y) or astronomical

- Power supply: 230V AC (-15%...+10%), 50/60Hz

Is a GPS module that allows you to capture the

programming

- Output: 4 bistable relays with change-over

information of date, time and position from satellites.

- Available programs: on/off, on pulse, on holiday,

contact from 8A (250V AC)

This information will be shared with GLX+Q BUS

off holiday, random, night (astronomical)

- Independent channels to control 9 loads (relays):

- 1 relay on board of the device

- 8 relays to be realized by connecting two actuators

- Maximum number of storable programs: 450

(900 events) allocable on 9 channels

- Possibility to automatically capture date, time and

geographical position connecting GEO BUS

- Manual override of the relay (temporary or

permanent)

- Possibility to copy:

- The programs of a channel on other channels

- A ll programs saber from another GLX+Q BUS

connected

- P assword protected lock keypad

- A utomatic time update (DST)

- M enu in five languages: English/Italian/Spanish/

French/German

34

Comfort Functions
Time Switches
72 x 72 Classic Plus and Galax Plus

Modular DIN-rail devices

Applications
Going from the pre-programmed switching of lighting (car park, advertising signs, public roads, etc.) over pre-programmed switching of heating equipment (home and work environment , water heating, etc.), to the preprogrammed switching of motors for pumps and fans and even to random presence simulation.
Standards
EN 60780-1, EN 60780-2-7

Features
Very easy programing by means of mechanical switches or digital buttons. Devices with daily and weekly event programing possibilities. Analogue devices have a shortest switching time of 15 minutes and digital device has 1 minute.
Functions
Pre-programmed switching of all kind of electrical devices.

Performance
Contact Maximum recommended load - Incandescent lamps - Fluorescent with compensation - Low voltage halogen lamps - Halogen (230V AC) - Low consumption lamps - Downlight lamps - LEDs - Non-compensated Running reserve Shortest switching time Modules Nominal current Accuracy Number of channels Operating voltage Fix on/off auto Own consumption at 230V Operating temperature range Flush mounting Surface mounting Number of memory position

DAY PROGRAMMABLE switched
3000W 1200VA 2000VA 3000W 1000VA 900VA 1000VA
>100h 15 min
4 16A/250 VAC ± 1 second/day at 25ºC
1 230V AC
yes 1.8W 0ºC...55ºC yes yes
-

WEEK PROGRAMMABLE switched
3000W 1200VA 2000VA 3000W 1000VA 900VA 1000VA
>100h
2 h 4 16A/250 VAC ± 1 second/day at 25ºC 1 230V AC yes 1.8W -10ºC...+45ºC yes yes -

DAY/WEEK PROGRAMMABLE changeover
3000W -
2000VA 3000W 1000VA
1000VA 1200VA 5 years 1 min
4 16A/250 VAC ± 1 second/day at 25ºC
1 230V AC
yes 6VA -10ºC...+45ºC yes yes 50

36

72 x 72 Classic Plus and Galax Plus

Comfort Functions

72 x 72 Classic Plus - Analogue time switches

Program No. of Nominal Running Shortest Fix No. of channels Current reserve switch on/off modules time auto

Cat. No.

Ref. No. Pack.

Operating Voltage: 120 or 230V AC

Day program 1x24

1CO 16A/250 VAC >100h 15 min yes

4 CLS+Q 15 1COM 16A 72x72 D 687467 1

1CO

Operating Voltage: 120 or 230V AC - 24 or 48V AC/DC

Week program 7x24

1CO 16A/250 VAC >100h 2 h

yes

4 CLS+Q 15 1COM 16A 72x72 W 687468 1

1CO
Operating Voltage: 120 or 230V AC - 24 or 48V AC/DC Day/Week program 1x24/7x24 1CO 16A/250 VAC 5 years 1min yes

4 GLX+Q 15 1COM 16A 72x72 W 687469 1

1CO

37

Comfort Functions
Light Sensitive Switches
Galax LSS

Modular DIN-rail devices

Applications
Control of lighting in shop windows, offices, car parking areas, controlling street lights, advertising signs, sun blinds, shutters, or even lighting in a home to simulate the presence of people.
Standards
VDE 0632, VDE 0633, EN 60669-2-1

Features
User presettable switch light intensity, intensity range and hysteresis (to avoid on/off a stable behavior). Reaction time is also user presettable. 1 channel and 2 channel with week-cycle, all with separate photocell are available besides a 1 channel all-in-one device.
Functions
Electronic switch controlled by the intensity of the ambient light , detected by a separate or integrated photocell (depending on the model). When the light intensity drops below the threshold setting. the switch changes its state to the on position. An increasing ambient light intensity eventually will switch off the device again.

Performance

Contact

Switching capacity

- Resistive load

Connectable Loads

- Incandescent Lamps

- Fluorescent Lamps

- LED <2W/2-8W/ >8W

DC switching capacity

Shortest switching time

Screws

Terminal capacity:

max

min

Operating voltage

Own consumption at 230V

Running reserve

Battery

Operating temperature range

Accuracy

Sealable

Light sensitive operating part

Light intensity switching range

Switching hysteresis

On/Off switching delay

Light sensitive sensor wire-length Light sensitive sensor protection degree Operationg temperature range

GLX+Q LUX 1NA 1 module 1 NO
16A/250 VAC
4000W 1000W 55/150/180W 16A/24VDC 20 sec
PH 4mm2 1mm2 230V AC (-20%...+10%) 6VA (1W)
-0ºC...+50ºC -
10 to 100 lux 0
15s ON 15s OFF max. 100m
IP65 -20ºC...+50ºC

GLX+Q LUX/T1COM 2 module
1 relay in monostable change over
16A/250 VAC
4000W 1000W 55/150/180W 16A/24VDC 1 min
PH 6mm2 1mm2 230V AC (-10%...+10%) 8VA (2W) 3 years Lithium -20ºC...+50ºC ± 1 second/day at 25ºC
yes
5 to 500 lux 1 to 50% threshold 1-50min (programmable) 1-50min (programmable)
max. 50m IP65
-20ºC...+50ºC

GLX+ LUX WALL
Relay with NO contact
10A/230 VAC
4000W 1000W 55/150/180W 16A/24VDC 10 sec
PH 4mm2 1mm2 230V AC (-10%...+10%) 8VA (1W)
-0ºC...+50ºC ± 1 second/day at 25ºC
-
3 to 70 lux 4 15s 15s -
IP54 -0ºC...+50ºC

38

Comfort Functions

Galax LSS

Program

No. of channels

Nominal Current

No. of modules

Cat. No.

Operating Voltage: 230V AC (-20%...+10%)

10 to 100 lux 1NO 16A/250 VAC

1

GLX+Q LUX 1NA 16A 1M

Ref. No. Pack.

687470

1

1NO

Operating Voltage: 230V AC (-10%...+10%)

5 to 500 lux

1CO 16A/250 VAC

2

GLX+Q LUX/T1COM16A2M 687472

1

1CO

Sensor for GLX+ QLUX

-

-

-

-

GLX+LSS EXT

687471

1

Operating Voltage: 230V AC (-10%...+10%)

3 to 70 lux

1NO

10A

-

GLX+ LUX WALL

687473

1

1NO

GLX LSS

39

Comfort Functions

By reference number

Modular DIN-rail devices

Ref. No.

Cat. No.

661000 661692 ASTBLR230 661693 ASTBLG230 661694 ASTBLB230 661695 ASTBLY230 685000 685693 CONTAXR1610008A 685694 CONTAXR1610012A 685695 CONTAXR1610024A 685696 CONTAXR1610048A 685697 CONTAXR1610115A 685699 CONTAXR1610230A 685700 CONTAXR1610240A 685701 CONTAXR161008A 685702 CONTAXR161012A 685703 CONTAXR161024A 685704 CONTAXR161048A 685705 CONTAXR161115A 685706 CONTAXR161230A 685707 CONTAXR161240A 685708 CONTAXR1620008A 685709 CONTAXR1620012A 685710 CONTAXR1620024A 685711 CONTAXR1620048A 685712 CONTAXR1620115A 685714 CONTAXR1620230A 685715 CONTAXR1620240A 685716 CONTAXR1611008A 685717 CONTAXR1611012A 685718 CONTAXR1611024A 685719 CONTAXR1611048A 685720 CONTAXR1611115A 685722 CONTAXR1611230A 685723 CONTAXR1611240A 685724 CONTAXR162008A 685725 CONTAXR162012A 685726 CONTAXR162024A 685727 CONTAXR162048A 685728 CONTAXR162115A 685729 CONTAXR162230A 685730 CONTAXR162240A 685731 CONTAXR1630012A 685732 CONTAXR1630024A 685733 CONTAXR1630048A 685734 CONTAXR1630230A 685735 CONTAXR1640008A 685736 CONTAXR1640012A 685737 CONTAXR1640024A 685738 CONTAXR1640048A 685740 CONTAXR1640230A 685741 CONTAXR1640240A 685742 CONTAXR1622008A 685743 CONTAXR1622012A 685744 CONTAXR1622024A 685745 CONTAXR1622048A 685747 CONTAXR1622230A 685748 CONTAXR1622240A 685779 PULSAR1610008A 685780 PULSAR1610012A 685781 PULSAR1610024A 685782 PULSAR1610048A 685783 PULSAR1610115A 685784 PULSAR1610230A 685785 PULSAR16123060 685786 PULSAR1610240A 685787 PULSAR161008A 685788 PULSAR161012A 685789 PULSAR161024A 685790 PULSAR161048A 685791 PULSAR161115A 685792 PULSAR161230A 685793 PULSAR161240A 685794 PULSAR1620008A 685795 PULSAR1620012A 685796 PULSAR1620024A 685797 PULSAR1620048A 685798 PULSAR1620115A 685799 PULSAR162023060 685800 PULSAR1620230A 685801 PULSAR1620240A 685802 PULSAR1611008A 685803 PULSAR1611012A 685804 PULSAR1611024A 685805 PULSAR1611048A 685806 PULSAR1611115A 685807 PULSAR1611230A 685808 PULSAR161123060 685809 PULSAR1611240A 685810 PULSAR162008A 685811 PULSAR162012A 685812 PULSAR162024A

Page
3 3 3 3
7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12

Ref. No.

Cat. No.

685813 PULSAR162048A 685814 PULSAR162115A 685815 PULSAR162230A 685816 PULSAR162240A 685817 PULSAR3210008A 685818 PULSAR3210012A 685819 PULSAR3210024A 685820 PULSAR3210048A 685821 PULSAR3210115A 685822 PULSAR3210230A 685823 PULSAR3210240A 685824 PULSAR3220008A 685825 PULSAR3220012A 685826 PULSAR3220024A 685827 PULSAR3220048A 685828 PULSAR3220115A 685829 PULSAR3220230A 685830 PULSAR3220240A 685831 PULSARC1610008A 685832 PULSARC1610012A 685833 PULSARC1610024A 685834 PULSARC1610048A 685835 PULSARC1610230A 685836 PULSARC1610240A 685837 PULSARC161008A 685838 PULSARC161012A 685839 PULSARC161 024A 685840 PULSARC161048A 685841 PULSARC161230A 685842 PULSARC161240A 685843 PULSARC1620008A 685844 PULSARC1620012A 685845 PULSARC1620024A 685846 PULSARC1620048A 685847 PULSARC1620230A 685848 PULSARC1620240A 685849 PULSARC162008A 685850 PULSARC162012A 685851 PULSARC162024A 685852 PULSARC162048A 685853 PULSARC162230A 685854 PULSARC162240A 685855 PULSARC3210008A 685856 PULSARC3210012A 685857 PULSARC3210024A 685858 PULSARC3210048A 685859 PULSARC3210230A 685860 PULSARC3210240A 685861 PULSARC3220008A 685862 PULSARC3220012A 685863 PULSARC3220024A 685864 PULSARC3220230A 685865 PULSARC3220240A 685866 PULSARC3220240A 685867 PULSARC3230008A 685868 PULSARC3230012A 685869 PULSARC3230024A 685870 PULSARC3230048A 685871 PULSARC3230230A 685872 PULSARC3230240A 685873 PULSARPU162024A 685874 PULSARPU162230A 685875 PULSARPU1620024A 685876 PULSARPU1620230A 685877 PULSARPU1640024A 685878 PULSARPU1640230A 685879 PULSARAUX11 685880 PULSARAUX20 685881 PULSARC 685882 PULSARM 685883 CONTAXRAUX11 685884 PULSARCAPM 685885 PULSARCAP 685930 CONTAXRAUX20 685934 CONTAXR2CAP 685945 CONTAXR1CAP 685993 PLT+MF230V16A1CO 685994 PLT+MFUNI16A1CO 685995 PLT+MFUNI8A3CO 685996 PLT+ASUNI16A1CO 685997 DIM500RL230V 685998 DIM300UNI230V 685999 DIMLC300UNI230V 686000 686069 PLC/CTX SP 687000 687436 CLS+S 15 1NA 16A 1M D 687437 CLS+Q 15 1NA 16A 1M D 687438 CLS+S 30 1COM 16A 2M D 687439 CLS+Q 30 1COM 16A 2M D 687440 CLS+Q 210 1COM 16A 2M W

Page
12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 7 13 13 7 7 7 21 21 21 21 25 25 25
13
31 31 31 31 31

Ref. No.

Cat. No.

Page

687441 CLS+S 15 1COM 16A 2.5M D

31

687442 CLS+Q 15 1COM 16A 2.5M D

31

687443 CLS+Q 120 1COM 16A 2.5M W 31

687444 GLX+Q 30 1NA 16A 1M D

33

687445 GLX+Q 30 1NA 16A 1M W

33

687446 GLX+Q 30 1NA 16A 1M AST D

33

687447 GLX+Q 30 1COM 16A 2M D ANA 33

687448 GLX+Q 30 1COM 16A 2M W ANA 33

687449 GLX+Q AST30 1NA 16A 2M D ANA 33

687450 GLX+Q 1 1COM 16A 2M DW

34

687451 GLX+Q 1 2COM 16A 2M DW

34

687452 GLX+Q 1 1COM 16A 2M DW IR 34

687453 GLX+Q 1 2COM 16A 2M DW IR 34

687454 GLX+Q 1 1COM 16A 2M AST IR 34

687455 GLX+Q 1 2COM 16A 2M AST IR 34

687456 GLX+ IR

34

687464 GLX+Q 1 1COM 16A 3M Y BUS 34

687465 GLX+ GEO BUS

34

687466 GLX+Q 4COM 8A 4M BUS

34

687467 CLS+Q 15 1COM 16A 72x72 D 37

687468 CLS+Q 15 1COM 16A 72x72 W 37

687469 GLX+Q 15 1COM 16A 72x72 W 37

687470 GLX+Q LUX 1NA 16A 1M

39

687471 GLX+LSS EXT

39

687472 GLX+Q LUX/T1COM16A2M

39

687473 GLX+ LUX WALL

39

687474 PULSAR SC 1-15 16A 1M

14

40

By catalogue number

Comfort Functions

Numerical Index

Cat. No.
A... ASTBLB230 ASTBLG230 ASTBLR230 ASTBLY230 C... CLS+Q 120 1COM 16A 2.5M W CLS+Q 15 1COM 16A 2.5M D CLS+Q 15 1COM 16A 72x72 D CLS+Q 15 1COM 16A 72x72 W CLS+Q 15 1NA 16A 1M D CLS+Q 210 1COM 16A 2M W CLS+Q 30 1COM 16A 2M D CLS+S 15 1COM 16A 2.5M D CLS+S 15 1NA 16A 1M D CLS+S 30 1COM 16A 2M D CONTAXR1610008A CONTAXR1610012A CONTAXR1610024A CONTAXR1610048A CONTAXR161008A CONTAXR1610115A CONTAXR161012A CONTAXR1610230A CONTAXR1610240A CONTAXR161024A CONTAXR161048A CONTAXR1611008A CONTAXR1611012A CONTAXR1611024A CONTAXR1611048A CONTAXR1611115A CONTAXR161115A CONTAXR1611230A CONTAXR1611240A CONTAXR161230A CONTAXR161240A CONTAXR1620008A CONTAXR1620012A CONTAXR1620024A CONTAXR1620048A CONTAXR162008A CONTAXR1620115A CONTAXR162012A CONTAXR1620230A CONTAXR1620240A CONTAXR162024A CONTAXR162048A CONTAXR162115A CONTAXR1622008A CONTAXR1622012A CONTAXR1622024A CONTAXR1622048A CONTAXR1622230A CONTAXR1622240A CONTAXR162230A CONTAXR162240A CONTAXR1630012A CONTAXR1630024A CONTAXR1630048A CONTAXR1630230A CONTAXR1640008A CONTAXR1640012A CONTAXR1640024A CONTAXR1640048A CONTAXR1640230A CONTAXR1640240A CONTAXR1CAP CONTAXR2CAP CONTAXRAUX11 CONTAXRAUX20 D... DIM300UNI230V DIM500RL230V DIMLC300UNI230V G... GLX+ GEO BUS GLX+ IR GLX+ LUX WALL GLX+LSS EXT GLX+Q 1 1COM 16A 2M AST IR GLX+Q 1 1COM 16A 2M DW GLX+Q 1 1COM 16A 2M DW IR GLX+Q 1 1COM 16A 3M Y BUS GLX+Q 1 2COM 16A 2M AST IR GLX+Q 1 2COM 16A 2M DW GLX+Q 1 2COM 16A 2M DW IR GLX+Q 15 1COM 16A 72x72 W GLX+Q 30 1COM 16A 2M D ANA GLX+Q 30 1COM 16A 2M W ANA GLX+Q 30 1NA 16A 1M AST D

Ref. No. Page
661694 3 661693 3 661692 3 661695 3
687443 31 687442 31 687467 37 687468 37 687437 31 687440 31 687439 31 687441 31 687436 31 687438 31 685693 7 685694 7 685695 7 685696 7 685701 7 685697 7 685702 7 685699 7 685700 7 685703 7 685704 7 685716 7 685717 7 685718 7 685719 7 685720 7 685705 7 685722 7 685723 7 685706 7 685707 7 685708 7 685709 7 685710 7 685711 7 685724 7 685712 7 685725 7 685714 7 685715 7 685726 7 685727 7 685728 7 685742 7 685743 7 685744 7 685745 7 685747 7 685748 7 685729 7 685730 7 685731 7 685732 7 685733 7 685734 7 685735 7 685736 7 685737 7 685738 7 685740 7 685741 7 685945 7 685934 7 685883 7 685930 7
685998 25 685997 25 685999 25
687465 34 687456 34 687473 39 687471 39 687454 34 687450 34 687452 34 687464 34 687455 34 687451 34 687453 34 687469 37 687447 33 687448 33 687446 33

Cat. No.

Ref. No. Page

GLX+Q 30 1NA 16A 1M D

687444 33

GLX+Q 30 1NA 16A 1M W

687445 33

GLX+Q 4COM 8A 4M BUS

687466 34

GLX+Q AST30 1NA 16A 2M D ANA 687449 33

GLX+Q LUX 1NA 16A 1M

687470 39

GLX+Q LUX/T1COM16A2M

687472 39

P...

PLC/CTX SP

686069 13

PLT+ASUNI16A1CO

685996 21

PLT+MF230V16A1CO

685993 21

PLT+MFUNI16A1CO

685994 21

PLT+MFUNI8A3CO

685995 21

PULSAR SC 1-15 16A 1M

687474 14

PULSAR1610008A

685779 12

PULSAR1610012A

685780 12

PULSAR1610024A

685781 12

PULSAR1610048A

685782 12

PULSAR161008A

685787 12

PULSAR1610115A

685783 12

PULSAR161012A

685788 12

PULSAR1610230A

685784 12

PULSAR1610240A

685786 12

PULSAR161024A

685789 12

PULSAR161048A

685790 12

PULSAR1611008A

685802 12

PULSAR1611012A

685803 12

PULSAR1611024A

685804 12

PULSAR1611048A

685805 12

PULSAR1611115A

685806 12

PULSAR161115A

685791 12

PULSAR161123060

685808 12

PULSAR1611230A

685807 12

PULSAR1611240A

685809 12

PULSAR16123060

685785 12

PULSAR161230A

685792 12

PULSAR161240A

685793 12

PULSAR1620008A

685794 12

PULSAR1620012A

685795 12

PULSAR1620024A

685796 12

PULSAR1620048A

685797 12

PULSAR162008A

685810 12

PULSAR1620115A

685798 12

PULSAR162012A

685811 12

PULSAR162023060

685799 12

PULSAR1620230A

685800 12

PULSAR1620240A

685801 12

PULSAR162024A

685812 12

PULSAR162048A

685813 12

PULSAR162115A

685814 12

PULSAR162230A

685815 12

PULSAR162240A

685816 12

PULSAR3210008A

685817 12

PULSAR3210012A

685818 12

PULSAR3210024A

685819 12

PULSAR3210048A

685820 12

PULSAR3210115A

685821 12

PULSAR3210230A

685822 12

PULSAR3210240A

685823 12

PULSAR3220008A

685824 12

PULSAR3220012A

685825 12

PULSAR3220024A

685826 12

PULSAR3220048A

685827 12

PULSAR3220115A

685828 12

PULSAR3220230A

685829 12

PULSAR3220240A

685830 12

PULSARAUX11

685879 13

PULSARAUX20

685880 13

PULSARC

685881 13

PULSARC161 024A

685839 13

PULSARC1610008A

685831 13

PULSARC1610012A

685832 13

PULSARC1610024A

685833 13

PULSARC1610048A

685834 13

PULSARC161008A

685837 13

PULSARC161012A

685838 13

PULSARC1610230A

685835 13

PULSARC1610240A

685836 13

PULSARC161048A

685840 13

PULSARC161230A

685841 13

PULSARC161240A

685842 13

PULSARC1620008A

685843 13

PULSARC1620012A

685844 13

PULSARC1620024A

685845 13

PULSARC1620048A

685846 13

PULSARC162008A

685849 13

PULSARC162012A

685850 13

PULSARC1620230A

685847 13

PULSARC1620240A

685848 13

PULSARC162024A

685851 13

PULSARC162048A

685852 13

PULSARC162230A

685853 13

Cat. No.
PULSARC162240A PULSARC3210008A PULSARC3210012A PULSARC3210024A PULSARC3210048A PULSARC3210230A PULSARC3210240A PULSARC3220008A PULSARC3220012A PULSARC3220024A PULSARC3220230A PULSARC3220240A PULSARC3230008A PULSARC3230012A PULSARC3230024A PULSARC3230048A PULSARC3230230A PULSARC3230240A PULSARCAP PULSARCAPM PULSARM PULSARPU1620024A PULSARPU1620230A PULSARPU162024A PULSARPU162230A PULSARPU1640024A PULSARPU1640230A

Ref. No. Page
685854 13 685855 13 685856 13 685857 13 685858 13 685859 13 685860 13 685861 13 685862 13 685863 13 685864 13 685865 13 685867 13 685868 13 685869 13 685870 13 685871 13 685872 13 685885 13 685884 13 685882 13 685875 13 685876 13 685873 13 685874 13 685877 13 685878 13

The policy of GE Energy Connections is one of continuous improvement. The right is reserved to alter the design or any structural details of the products at any time without giving notice.
July 2017 GE Energy Connections

41

124732

GE Energy Connections

Since Thomas Edison patented the world's first circuit breaker, Industrial Solutions has been transforming the future of electrification. We design electrical solutions at the crossroads of digital and industrial ­ smart, rugged and equipped to control electricity from the grid to its point of use. Every day, we partner with our customers to solve their toughest energy challenges and reimagine industry in a way that only the world's digital industrial company can.

Belgium GE Industrial Belgium Nieuwevaart 51 B-9000 Gent Tel. +32 (0)9 265 21 11
Finland GE Industrial Solutions Kuortaneenkatu 2 FI-00510 Helsinki Tel. +358 (0)10 394 3760
France GE Industrial Solutions 204, Rue du Rond-Point du Pont de Sèvres F-92100 Boulogne-Billancourt Tel. +33 (0)800 912 816
Germany GE Industrial Solutions Robert-Bosch Str. 3 D-50354 Hürth-Efferen Tel. +49 (0) 2233/ 9719-0
Hungary GE Hungary Kft. Vaci ut 81-83. H-1139 Budapest Tel. +36 1 447 6050
Italy GE Industrial Solutions Centro Direzionale Colleoni Via Paracelso 16 Palazzo Andromeda B1 I-20864 Agrate Brianza (MB) Tel. +39 039 637 371

Netherlands GE Industrial Solutions Parallelweg 10 NL-7482 CA Haaksbergen Tel. +31 (0)53 573 03 03
North Africa General Electric International, sq Inc. (Succursale) Crystal Building 3, 3rd Floor, Marina Casablanca, 20050 Casablanca, Morroco Tel. +212 529 025 502
Norway GE Industrial Solutions Drammensveien 165 0277 Oslo Tel. +47 (0)8 001 72 56
Poland GE Power Controls Gdanski Business Centre Inflancka 4C, bud. D 00-189 Warszawa Tel. +48 22 520 53 53
Rudawka 96 43-382 Bielsko-Biala Tel. +48 33 828 62 33
Russia GE Industrial Solutions 27/8, Electrozavodskaya street Moscow, 107023 Tel. +7 495 937 11 11

South Africa GE Industrial Solutions Unit 4, 130 Gazelle Avenue Corporate Park Midrand 1685 P.O. Box 76672 Wendywood 2144 Tel. +27 11 238 3000
Spain GE POWER CONTROLS IBÉRICA, S.L. Calle Miño 122 Naves E-F Polígono Industrial Santa Margarita 08223 Terrassa (Barcelona) Tel. +34 900 993 625
Sweden GE Industrial Slutions Vendevägen 89 SE-182 32 Danderyd Tel. +46 (0)20 79 16 70
United Arab Emirates GE Industrial Solutions Injaz Building, 3rd Floor Dubai Internet City PO Box 11549, Dubai Tel. +971 4 4546912
United Kingdom GE Industrial Solutions 2 The Arena, Downshire Way Bracknell, Berkshire RG12 1PU Tel. +44 (0)800 587 1239

ex.geindustrial.com

DEC1007 - 694569 Ref. R/2586/E/X 0.1 Ed. 07/17 * Trademark of General Electric Company © Copyright GE Energy Connections 2017


Adobe PDF Library 11.0