N USER GUIDE ETHERNET MODULE (REF. RS2NET)

USER GUIDE ETHERNET MODULE (REF. RS2NET) Technical manual V1.0 NetBus is a module produced by Sugar Valley in order to allow the interconnection between a Sugar Valley device

Modulo Ethernet Hayward Kripsol Sugar Valley | PoolComet

PDF preview unavailable. Download the PDF instead.

manual-de-instalacion-modulo-ethernet-hayward-aquarite
EN
USER GUIDE ETHERNET MODULE (REF. RS2NET)
Technical manual V1.0

NetBus is a module produced by Sugar Valley in order to allow the interconnection between a Sugar Valley device and the VistaPool system. Likewise, the NetBus module allows the work with the PoolShow system of Sugar Valley to see the pool parameters.
IMPORTANT: The NETBUS module and the PoolShow system must to be in the same network local to work properly.
This module allows an internet wired connection, replacing the WIFI solution
IMPORTANT: The manual contains instructions for the acces to a low level of differents operating ways of the devices, like the information used to generate a firmware upgrade file. It's recommended to keep this document only for the internal use of Sugar Valley.

NETBUS module

Local internet Network

ADSL modem

Pool controller

Internet

Vistappol web server
Starting the system: When the NetBus box is opened, you will find the folloging parts: - NETBUS module - MODBUS RTU wire connection - Ethernet wire The device can power from an 12V external adapter, or from the device. To install, complete the following steps:

1

1. Connect the NETBUS module as follows:

Power 9Va 27V

USB

RS485

MODBUS RTU

Ethernet 10/100

Button

The Ethernet port must be connected to the router/switch you have available. The RS485 MODBUS RTU port must be connected to the connector labeled as WIFI in the Sugar Valley device.
2. Once the connection is made, toggle the power switch on your Sugar Valley device and wait 60 seconds.
3. Configure the Internet connection as detailed in the Sugar Valley instructions (Main Menu > Settings > Internet > Settings). It's recommended to use DHCP as the connection parameter, but if you preffer, you can set the parameters of a connection with fixed IP.
4. Once the settings are placed, check that your computer connects to the Internet, if not, turn off and turn on the device to ensure that the configuration parameters have been applied correctly.

To check that the device is working correctly, look at the status of the 4 LED's of the NETBUS module:

Power

MODBUS connection Internet connection Activity indicator

2

Indicator
Power MODBUS connection
Internet connection

Off
The device is off and it's not working. Check the power
The search of the equipment has not sterted
There is no configuration to access the internet. Wait until the device MODBUS search is finished.

Blinking

On
There is POWER on the device.

Serching device on MODBUS System found and network. Wait 1 - 2 minutes identified

The internet connection is starting. Wait 1 - 2 minutes.

Device connected

In normal conditions, the activity indicator will go on and off depending on the network traffic. When the 3 LEDs on the right remain solid lighted and the left one blinks sometimes, means a correct operation