Falcon Ultra B Operator and Parts Manual

tmf

Model Part No.: FALCON ULTRA B t - Nobles

OPERATOR AND PARTS MANUAL BATTERY AUTOMATIC CARPET EXTRACTOR 608418 Rev. 06 (06-2014) *608418* Model Part No.: FALCON ULTRA Bt 608350 608351 - PAC For the latest Parts manuals and other

PDF Model Part No.: FALCON ULTRA B t - Nobles

Go Now

Nobles.com View guide user manual › Url: https://www.nobles.com/content/dam/nobles/Products/machines/Carpet Extractors/Falcon Ultra B/operator-parts-manuals/608418

PDF preview unavailable. Download the PDF instead.

608418
Model Part No.: 608350 608351 - PAC

®
FALCONt ULTRA B
BATTERY AUTOMATIC CARPET EXTRACTOR
OPERATOR AND PARTS MANUAL

For the latest Parts manuals and other language Operator manuals, visit:
www.nobles.com/manuals
www.nobles.com

608418 Rev. 06 (06-2014)
*608418*

OPERATION
This manual is furnished with each new model. It provides necessary operation and maintenance instructions and an illustrated parts list.
Read this manual completely and understand the machine before operating or servicing it.
When ordering replacement parts, use the illustrated parts lists section in this manual. Before ordering parts or supplies, be sure to have your machine model number and serial number available. Parts and supplies may be ordered by phone or mail from any authorized parts and service center, distributor or from any of the manufacturer's subsidiaries.
This machine will provide excellent service. However, the best results will be obtained at minimum costs if:
S The machine is operated with reasonable care. S The machine is maintained regularly - per the
machine maintenance instructions provided.
S The machine is maintained with manufacturer
supplied or equivalent parts.
PROTECT THE ENVIRONMENT Please dispose of packaging materials, old machine components such as batteries, hazardous fluids such as antifreeze and oil, in a safe environmentally way according to your local waste disposal regulations.
Always remember to recycle.

MACHINE DATA
Please fill out at time of installation for future reference. Model No.Install. Date Serial No.-

Tennant Company PO Box 1452 Minneapolis, MN 55440 Phone: (800) 553- 8033 or (763) 513- 2850 www.nobles.com
Specifications and parts are subject to change without notice. Copyright E1999, 2002, 2005, 2007, 2012, 2013, 2014 Tennant Company. All rights reserved. Printed in U.S.A. Nobles is a registered United States trademark of Tennant Company.
2

Falcont Ultra B (06- 14)

OPERATION

TABLE OF CONTENTS
SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . 4 SAFETY LABEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 MACHINE COMPONENTS . . . . . . . . . . . . . . . . . . . 6 CONTROL PANEL SYMBOLS . . . . . . . . . . . . . . . 6 MACHINE INSTALLATION . . . . . . . . . . . . . . . . . . . 7
UNCRATING MACHINE . . . . . . . . . . . . . . . . . . 7 INSTALLING BATTERIES . . . . . . . . . . . . . . . . 7
MACHINE SETUP . . . . . . . . . . . . . . . . . . . . . . . . . . 8 FILLING SOLUTION TANK . . . . . . . . . . . . . . . 8 ADJUSTING CONTROL GRIP HEIGHT . . . . 8
MACHINE OPERATION . . . . . . . . . . . . . . . . . . . . . 9 PRE- OPERATION CHECKS . . . . . . . . . . . . . . 9 WHILE OPERATING MACHINE . . . . . . . . . . . 10 CIRCUIT BREAKERS . . . . . . . . . . . . . . . . . . . . 10
OPTIONAL ACCESSORY TOOL SETUP AND OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 DRAINING TANKS . . . . . . . . . . . . . . . . . . . . . . . . . . 11
DRAINING RECOVERY TANK . . . . . . . . . . . . 12
DRAINING SOLUTION TANK . . . . . . . . . . . . . . . . 12 BATTERY CHARGING . . . . . . . . . . . . . . . . . . . . . . 12 MACHINE MAINTENANCE . . . . . . . . . . . . . . . . . . 14
DAILY MAINTENANCE . . . . . . . . . . . . . . . . . . . 14 MONTHLY MAINTENANCE . . . . . . . . . . . . . . 15 QUARTERLY MAINTENANCE . . . . . . . . . . . . 15 BATTERY MAINTENANCE . . . . . . . . . . . . . . . 16
TRANSPORTING MACHINE . . . . . . . . . . . . . . . . . 17 STORING MACHINE . . . . . . . . . . . . . . . . . . . . . . . . 17 RECOMMENDED STOCK ITEMS . . . . . . . . . . . . . 17

TROUBLE SHOOTING . . . . . . . . . . . . . . . . . . . . . . 18

SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 20

MACHINE DIMENSIONS . . . . . . . . . . . . . . . . . . . . 21

ELECTRICAL DIAGRAMS . . . . . . . . . . . . . . . . . . . 22

PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

SOLUTION TANK GROUP . . . . . . . . . . . . . . . . 24

RECOVERY TANK GROUP

(S/N 10430222-

) . . . . . . . . . . . . . . . . 26

RECOVERY TANK GROUP

(S/N 00000000- 10430221) . . . . . . . . . . . . . . . 28

CONSOLE GROUP . . . . . . . . . . . . . . . . . . . . . . 30

CONTROL PANEL GROUP . . . . . . . . . . . . . . . 32

LIFT GROUP . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

DRIVE GROUP . . . . . . . . . . . . . . . . . . . . . . . . . 36

BRUSH BASE GROUP . . . . . . . . . . . . . . . . . . . 38

SOLUTION GROUP . . . . . . . . . . . . . . . . . . . . . 40

PUMP BREAKDOWN GROUP . . . . . . . . . . . . 42

BATTERY AND CHARGER GROUP . . . . . . . 43

OPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 WAND GROUP, LOW PRESSURE, 13 in / 330 mm . . . . . . . . . . . . . . . . . . . . . . . . . 44 WAND GROUP, LOW PRESSURE, 16 in / 406 mm . . . . . . . . . . . . . . . . . . . . . . . . . 46 HAND TOOL, 5 in / 127 mm . . . . . . . . . . . . . . . 48 HAND TOOL, CREVICE, 3 in / 76 mm . . . . . . 48 HAND TOOL, UPHOLSTERY, LOW PRESSURE . . . . . . . . . . . . . . . . . . . . . . 49 HOSES, SOLUTION AND VACUUM . . . . . . . 50 PUMP- UP CARPET SPRAYER . . . . . . . . . . . 50

Falcont Ultra B (03- 12)

3

OPERATION
SAFETY PRECAUTIONS
This machine is intended for commercial use. It is designed exclusively to clean carpets and upholstery in an indoor environment and is not constructed for any other use. Use only recommended accessory tools and commercially available carpet cleaners intended for machine application.
All operators must read, understand and practice the following safety precautions.
The following warning alert symbol and the "FOR SAFETY" heading are used throughout this manual as indicated in their description:
WARNING: To warn of hazards or unsafe practices which could result in severe personal injury or death. FOR SAFETY: To identify actions which must be followed for safe operation of equipment.
Failure to follow these warnings may result in personal injury, electrical shock, fire or explosion.
WARNING: Fire Or Explosion Hazard: - Never Use Flammable Liquids Or Operate
Machine in Or Near Flammable Liquids, Vapors Or Combustible Dusts. This machine is not equipped with explosion proof motors. The electric motors will spark upon start up and during operation which could cause a flash fire or explosion if machine is used in an area where flammable vapors/liquids or combustible dusts are present. - Do Not Pick Up Flammable Materials Or Reactive Metals. - Batteries Emit Hydrogen Gas. Keep Sparks And Open Flame Away. Keep Battery Compartment Open When Charging.
WARNING: Electrical Shock Hazard. Disconnect Battery Cables Before Servicing Machine.
WARNING: Spinning Brush. Keep Hands Away. Turn Off Power Before Working On Machine.

The following information signals potentially dangerous conditions to the operator or equipment:
FOR SAFETY:
1. Do not operate machine: - With flammable liquids or near flammable vapors as an explosion or flash fire may occur. - Unless trained and authorized. - Unless operation manual is read and understood. - If not in proper operating condition.
2. Before operating machine: - Make sure all safety devices are in place and operate properly. - Place wet floor signs as needed.
3. When using machine: - Go slow on inclines and slippery surfaces. - Use care when reversing machine. - Report machine damage or faulty operation immediately. - Never allow children to play on or around. - Follow mixing and handling instructions on chemical containers.
4. Before leaving or servicing machine: - Stop on level surface. - Turn off machine. - Set parking brake, if equipped.
5. When servicing machine: - Avoid moving parts. Do not wear loose jackets, shirts, or sleeves. - Disconnect battery connections before working on machine. - Wear protective gloves and eye protection when handling batteries or battery cables. - Avoid contact with battery acid. - Block machine tires before jacking up. - Use hoist or jack that will support the weight of the machine. - Do not power spray or hose off machine. Electrical malfunction may occur. - Use manufacturer supplied or approved replacement parts. - All repairs must be performed by a qualified service person. - Do not modify the machine from its original design.

4

Falcont Ultra B (07- 05)

OPERATION

6. When transporting machine: - Turn machine off. - Do not lift machine when batteries are installed. - Get assistance when lifting machine.

- Use a recommended ramp when loading/unloading on/off truck or trailer.
- Use tie- down straps to secure machine to truck or trailer.
- Put brush/pick-up head in the lowered position.

SAFETY LABEL

The safety label appears on the machine in the location indicated. Replace the label if it is missing or becomes damaged or illegible.

WARNING LABEL - LOCATED ON TOP OF THE RECOVERY TANK.

Falcont Ultra B (07- 07)

5

OPERATION

MACHINE COMPONENTS

21 24 23

1 22
25 26

32 2

7 34 56

17 9 10

29 31

28 27 30

13 15
16
12

20

11

19 18

1. Control Console 2. Control Roll Grips 3. Main ON/OFF Switch 4. Pump ON/OFF Switch 5. Vacuum ON/OFF Switch 6. Brush/Pickup Head Actuator Switch 7. Battery Meter 8. Speed Control Knob 9. Main/Pump/Brush Circuit Breaker 10. Vacuum/Drive Circuit Breaker 11. Intake Vacuum Hose

12. Brush/Pickup Head Actuator 13. Adjustable Control Console Levers 14. Recovery Tank Drain Hose 15. Solution Tank Drain Hose 16. 19L (5 Gal) Increment Markers 17. Rear Fill Port 18. Inline Solution Filter Strainer 19. Accessory Solution hose Coupler 20. Accessory Vacuum Hose Connecter 21. Recovery Tank 22. Recovery Tank Lid

23. Solution Tank 24. Solution Tank Fill Door 25. Battery Compartment 26. Charger Plug 27. Drive Wheels 28. Rear Casters 29. Wall Rollers 30. Pick-up Head 31. Brush Base 32. Reverse Switch

CONTROL PANEL SYMBOLS

8 14

Main Power Pump
Vacuum

Less Brush Pressure
More Brush Pressure
Battery Charge Meter

Fast Speed
Slow Speed
Vacuum/drive Motor Circuit Breaker

Main Power Circuit Breaker
Reverse

6

Falcont Ultra B (07- 05)

MACHINE INSTALLATION
UNCRATING MACHINE
1. Carefully check the shipping crate for signs of damage. Report damages at once to carrier.
2. Check the contents list. Contact distributor for missing items.
Contents: 1 - Battery Tray #601991 2 - Batteries, 225 Ah 12V #1070591 (included with
machine PAC) 1 - Battery Cable #6 x 15" Black #130364 4 - Battery Post Caps #45962 4 - Black Battery Boots #611221 1 - Battery Charger 24VDC/19A #1029256 (included
with machine PAC) Batteries and charger are packaged separately.
3. To uncrate your machine, remove the shipping hardware and straps that secure the machine to the pallet. With assistance, carefully lift the machine off the pallet.
ATTENTION: Do not roll machine off pallet unless a ramp is used, machine damage may occur. ATTENTION: To prevent possible machine damage, install batteries after removing machine from shipping pallet.
INSTALLING BATTERIES
WARNING: Fire Or Explosion Hazard. Batteries Emit Hydrogen Gas. Keep Sparks And Open Flame Away. Keep Battery Hood Open When Charging. FOR SAFETY: When servicing machine, wear protective gloves and eye protection when handling batteries and battery cables. Avoid contact with battery acid. Battery Specifications: Two 12 volt, deep cycle batteries. Consult with an Authorized Distributor for specific batteries. Maximum battery dimensions are 178 mm (7 in) W x 381 mm (15 in) L x 356 mm (14 in) H.

OPERATION
1. Turn all switches to the OFF position. 2. Carefully hinge open recovery tank to access
battery compartment. Remove loose battery cable from compartment (Figure 1).

FIG. 1
3. Carefully install batteries into battery tray at bottom of compartment and arrange battery posts as shown (Figure 2).

(+)

(- )

(- )

(+)

FIG. 2
ATTENTION: Do not drop batteries into compartment, battery and machine housing damage may result. This damage in not covered by warranty.
4. Before connecting battery cables, make sure terminals and posts are clean. Use a post cleaner and wire brush to clean posts and terminals.
5. Connect battery cables to battery posts as shown (RED TO POSITIVE & BLACK TO NEGATIVE) (Figure 2).
NOTE: Apply a light coating of non-metallic grease or protective spray on the cable connections to prevent battery corrosion.

Falcont Ultra B (06- 14)

7

OPERATION
6. After batteries are properly installed, turn on the main switch and check battery meter charge level to ensure batteries are fully charged. Charge if necessary, See Battery Charging (Figure 3).
FIG. 3
MACHINE SETUP
FILLING SOLUTION TANK 1. Transport machine to filling station. Raise
brush/pick-up head when transporting. 2. Turn off main switch. FOR SAFETY: Before leaving or servicing machine, stop on level surface, turn off machine. 3. Open solution fill door at front of machine and fill
solution tank with 64 L (17 gal) of clean water, 60C (140F) maximum temperature. Or you can use the rear fill port to fill solution tank. Twist off plug and insert hose to fill. The clear tube below the fill port has 19 L (5 gal) increment markers to indicate amount of water in tank (Figure 4).

NOTE: The water must not be hotter than 60_C (140_F) or tank damage may occur. NOTE: When filling the solution tank with a bucket, make sure that the bucket is clean. Do not use the same bucket for filling and draining the machine.
WARNING: Fire or Explosion Hazard. Never Use Flammable Liquids. 4. Add cleaning chemical. See proper dilution ratio
instructions on bottle. FOR SAFETY: When using machine, follow mixing and handling instructions on chemical containers. ATTENTION: Use only recommended detergents. Machine damage due to improper detergent usage will void the manufacturer's warranty. Contact your Tennant Sales Representative for detergent recommendations.
ADJUSTING CONTROL GRIP HEIGHT The machine has three control grip height settings. 1. Locate two spring loaded levers below console. 2. Squeeze levers together and lift or lower control
grips to a comfortable operating height (Figure 5).
FIG. 5

FIG. 4
8

Falcont Ultra B (07- 05)

MACHINE OPERATION
FOR SAFETY: Do not operate machine, unless operation manual is read and understood.
WARNING: Fire Or Explosion Hazard. Never Operate Machine In Or Near Flammable Liquids, Vapors Or Combustible Dusts.
PRE- OPERATION CHECKS
- Vacuum floor and remove any debris. - Check battery meter charge level to ensure
batteries are fully charged (See BATTERY CHARGING). - Check that spray bar is installed. - Check that inline strainer filter is installed. - Inspect spray tips for proper spray pattern (See DAILY MAINTENANCE).
1. Turn on main switch. 2. Lower brush/pick-up head to floor by depressing
brush height switch (Figure 6).

OPERATION
FIG. 7
5. To begin cleaning, rotate control grips completely forward and gradually turn speed control knob to desired cleaning speed (Figure 7). For optimum cleaning results, operate at a cleaning speed of 15 m (50 ft) per minute for deep cleaning and 30 m (100 ft) per minute for interim cleaning. WARNING: Fire Or Explosion Hazard. Do Not
Pick Up Flammable Materials Or Reactive Metals. 6. To stop machine, release control grips. 7. To operate machine in reverse, simply pull reverse
switch backwards one speed (Figure 8).

FIG. 6
3. Turn on vacuum and pump switches.
NOTE: The brush and pump will start once control grips are rotated.
4. Before you begin cleaning, turn speed control knob to slowest speed (Figure 7).

FIG. 8
8. After cleaning carpets, allow sufficient time for carpet to dry. Use a carpet blower to reduce drying time.

Falcont Ultra B (07- 05)

9

OPERATION

WHILE OPERATING MACHINE
WARNING: Fire Or Explosion Hazard. Do Not Pick Up Flammable Materials Or Reactive Metals.
1. Periodically check for foam buildup in recovery tank (look through clear lid). If excessive foam buildup begins to develop, pour a recommended foam control solution into recovery tank.
ATTENTION: Do not allow foam to enter the float shut-off screen, vacuum motor damage will result. Foam will not activate the float shut-off screen.
2. Always operate at a slower speed when cleaning around walls or obstacles.
3. Always reduce speed to maintain control when turning machine.
4. Overlap each pass by 50 mm (2 in).
5. Before reaching end of cleaning path, turn off pump switch and continue to drive machine forward to extract solution.
6. Periodically check battery meter discharge level. When needle drops to the red zone, recharge batteries.
ATTENTION: Do not continue to run machine when battery meter needle is in the red zone, battery damage will result.
7. While cleaning, view clear hose gallon marker for remaining cleaning solution. Each mark on hose indicates 19 L (5 gal).
8. When solution tank runs dry, turn off pump and vacuum switches, raise brush, and transport machine to draining area (See DRAINING TANKS).
9. If the cleaning path leaves streaks, spray tip cleaning is required (See MONTHLY MAINTENANCE).
CIRCUIT BREAKERS
The machine is equipped with two resetable circuit breakers, Main (15A) and Vacuum/Drive (60A), to protect machine from damage. If a circuit breaker should trip during operation, determine the cause, allow motor to cool and then manually reset the breaker button. The circuit breaker panel is located at rear of machine (Figure 9).
The vacuum/drive circuit breaker (60A) is designed to stop current flow by manually pulling out the circuit breaker button. This allows you to keep the machine stationary while performing specific maintenance procedures.

FIG. 9
Contact an Authorized Service Center for machine repairs. FOR SAFETY: When servicing machine, all repairs must be performed by a qualified service person.
OPTIONAL ACCESSORY TOOL SETUP AND OPERATION
Machine is equipped with accessory tool connections. Accessory tool enables you to reach areas that the machine is unable, such as alcoves, stairs and corners (See Options). 1. Vacuum area before cleaning. 2. Fill solution tank and add cleaning chemical (See
FILLING SOLUTION TANK). WARNING: Fire or Explosion Hazard. Never
Use Flammable Liquids. 3. Disconnect lower vacuum hose at rear of machine
and replace with accessory vacuum hose (Figure 10).
FIG. 10

10

Falcont Ultra B (07- 05)

4. Connect solution hose to accessory tool coupler, located at lower rear of machine (Figure 11).

OPERATION

FIG. 11
5. Connect accessory tool to solution hose and vacuum hose (Figure 12).
FIG. 12
6. Turn on main, pump and vacuum switches. 7. Take accessory tool and begin cleaning at top of
area and work backwards toward machine. WARNING: Fire Or Explosion Hazard. Do Not
Pick Up Flammable Materials Or Reactive Metals. 8. Place accessory tool head on area to be cleaned;
squeeze trigger, apply downward pressure on accessory tool head, and slowly pull tool backwards. Release trigger 152 mm (6 in) from end of stroke (Figure 13).

FIG. 13
9. When returning for next stroke, push accessory tool forward over same path with trigger released. Continue this pull and push method with a 50 to 102 mm (2 to 4 in) overlap of each stroke.
NOTE: For heavily soiled areas, repeat stroke or change angle of stroke. 10. Empty recovery tank when solution tank runs dry
(See DRAINING TANKS). ATTENTION: Do not allow foam to enter the float shut-off screen, vacuum motor damage will result. Foam will not activate the float shut-off screen.
DRAINING TANKS
The recovery tank should be drained and cleaned out after every use. The solution tank should be cleaned out periodically to remove any corrosion.
Transport the machine to a draining site, turn machine off and follow the draining instructions below:
ATTENTION: Raise brush/pick-up head when transporting machine to floor drain. FOR SAFETY: Before leaving or servicing machine, stop on level surface, turn off machine.

Falcont Ultra B (07- 05)

11

OPERATION

DRAINING RECOVERY TANK Always empty recovery tank when refilling solution tank. You may refill solution tank while emptying recovery tank. To drain recovery tank, perform the following steps: ATTENTION: If recovery tank is not emptied between fill- ups, foam or water will enter vacuum standpipe and damage vacuum motor. Float shut- off screen will not keep foam out of standpipe. Vacuum damage due to foam or water is not covered by warranty. 1. Remove drain hose from holder, position hose
over floor drain and twist off drain hose cap. To completely drain recovery tank, hinge open tank and flip up tank support stand to rest tank on (Figure 14).
FIG. 14
2. Rinse out recovery tank after each use. This will prevent a foul odor and residue buildup in tank. Unscrew clear lid on recovery tank and rinse out the tank with hose. Be careful not to spray water into float shut-off screen.
NOTE: The water must not be hotter than 60_C (140_F) or tank damage may occur. Do not use steam to clean tank. NOTE: When filling the solution tank with a bucket, make sure that the bucket is clean. Do not use the same bucket for filling and draining the machine. 3. Replace drain hose plug tightly when tank is
empty.
DRAINING SOLUTION TANK
To drain leftover cleaning solution from solution tank, follow steps below: 1. Pull clear hose off hose barb at rear of machine
and drain solution into floor drain or bucket (Figure 15).

FIG. 15
2. Rinse out solution tank and solution system with clean water after each use. This will prevent clogging due to chemical buildup. Use clear hose to drain solution tank when rinsing.
NOTE: The water must not be hotter than 60_C (140_F) or tank damage may occur. Do not use steam to clean tank.
NOTE: When filling the solution tank with a bucket, make sure that the bucket is clean. Do not use the same bucket for filling and draining the machine.
3. When reconnecting clear hose to hose barb, be certain hose is completely pushed onto hose barb.
BATTERY CHARGING
ATTENTION: To prolong the life of the batteries and to provide optimum machine performance, ONLY recharge the batteries after a total of 30 minutes of use or more. Do not leave batteries discharged for lengthy periods.
The following charging instructions are intended for battery chargers supplied with the machine. Only use a battery charger with the following specifications to prevent battery damage.
BATTERY CHARGER SPECIFICATIONS:
S CHARGER TYPE:
- FOR LEAD ACID BATTERIES
S OUTPUT VOLTAGE - 24 VOLTS S OUTPUT CURRENT - 25 AMPS MAXIMUM S AUTOMATIC SHUTOFF CIRCUIT S FOR DEEP CYCLE BATTERY CHARGING

12

Falcont Ultra B (07- 05)

WARNING: Fire Or Explosion Hazard. Batteries Emit Hydrogen Gas. Keep Sparks And Open Flame Away. Keep Battery Hood Open When Charging.
1. Transport machine to a well ventilated area for charging.
2. Lead acid batteries: Before charging the batteries, check the electrolyte level in each battery cell (Figure 16).

OPERATION
3. Connect the charger's AC power supply cord to a properly grounded receptacle (Figure 18).
Grounded 3 Hole Outlet
Ground Pin (120V)
FIG. 18
5. Plug charger's DC output connector to battery connector located near battery compartment. Rest the recovery tank on the support stand to promote ventilation during charging (Figure 19).

FIG. 16
FOR SAFETY: When servicing machine, wear protective gloves and eye protection when handling batteries and battery cables. Avoid contact with battery acid.
The electrolyte level (A) should slightly cover the battery plates (B). Add distilled water as needed. DO NOT OVERFILL, the fluid may expand and overflow while charging. Replace cell caps before charging (Figure 17).
A B
FIG. 17

FIG. 19
FOR SAFETY: Do not operate charger unless cord is properly grounded.
6. The charger will automatically begin charging and shut off when fully charged.
NOTE: The machine will not operate once the battery charger is connected.
ATTENTION: Do not disconnect the charger's DC cord from the machine's receptacle when the charger is operating. Arcing may result. If the charger must be interrupted during charging, disconnect the AC power supply cord first.
WARNING: Fire Or Explosion Hazard. Batteries Emit Hydrogen Gas. Keep Sparks And Open Flame Away. Keep Battery Compartment Open When Charging.

Falcont Ultra B (07- 05)

13

OPERATION
9. After charging, check the electrolyte level (A) again. The level should be approximately 1 cm from the bottom of the fill- port (B) (Figure 20). Add distilled water if needed. DO NOT OVERFILL.
B
A

FIG. 20
MACHINE MAINTENANCE
To keep machine in good working condition, simply follow daily, monthly and quarterly maintenance procedures.
FOR SAFETY: Before leaving or servicing machine, stop on level surface, turn off machine.
WARNING: Electrical Hazard. Disconnect Battery Cables Before Servicing Machine. ATTENTION: Contact an Authorized Service Center for machine repairs. Machine repairs performed by other than an authorized person will void your warranty.
DAILY MAINTENANCE (After Every Use)
1. Inspect spray tips for proper spray pattern: a. Pull out vacuum/drive circuit breaker button, located at rear of control console. b. Lower brush/pick- up head and remove detachable spray bar from brush base. Do not disconnect bar from quick coupler. Raise brush after removing spray bar (Figure 21). c. Turn on main and pump switches. d. Rotate control grips and observe spray pattern. Pattern should fan out evenly across the width of the spray bar. e. Clean or replace defective twist-out spray tips if necessary (See MONTHLY MAINTENANCE).

FIG. 21
2. Drain and clean out the recovery tank. 3. Remove and clean the float shut- off screen
located in the recovery tank (Figure 22).
FIG. 22
4. Drain the solution tank and rinse out the inside with hot water, 60C (140F) maximum temperature, as needed.
5. Clean the machine with an all purpose cleaner and damp cloth.
FOR SAFETY: When cleaning machine, do not power spray or hose off machine. Electrical malfunction may occur. 6. Remove inline strainer filter and rinse out. Make
sure solution tank is empty before removing filter. Filter is located under machine at rear (Figure 23).

FIG. 23

14

Falcont Ultra B (07- 05)

7. Inspect brush for entangled debris.
8. Recharge the batteries after a total of 30 minutes of use or more (Figure 24).

OPERATION
4. Remove detachable spray bar from brush base. Remove twist-out spray tips from spray bar and soak in 118 ml (4 oz) acetic acid solution for up to 6 hours. After soaking tips, use a small brush to remove excess alkaline and rinse thoroughly. DO NOT use pointed objects to unplug spray tips (Figure 25).

FIG. 24
MONTHLY MAINTENANCE (Every 80 hours of use)
1. Clean the battery tops to prevent corrosion (See BATTERY MAINTENANCE).
2. Check for loose battery cable connections.
3. Flush out tanks and solution lines: a. Pull out the vacuum/drive circuit breaker button, located at rear of control console. b. Pour 750 ml (24 oz) of an acetic acid solution with 11.3 L (3 gal) of hot water into solution tank; do not exceed 60_C (140_F).
FOR SAFETY: When using machine, follow mixing and handling instructions on chemical containers.
c. Turn on the main and pump switches. d. Over a floor drain, rotate control grips and
hold for one to two minutes. e. Shut off power and let machine set overnight
to allow acetic acid solution to breakdown alkaline buildup. f. Next day, operate pump to disperse remaining acetic acid solution. g. Then rinse out solution tank and solution lines with clean water. h. Reset drive circuit breaker button when completed.

FIG. 25
5. Lubricate caster grease fittings with a water resistant grease.
6. Lubricate all linkage pivot points with silicone spray, then coat with a water resistant grease to maintain a smooth operation.
7. Check the machine for loose nuts and bolts. 8. Check the machine for leaks.
QUARTERLY MAINTENANCE
Every 250 hours, check the drive transaxle motor, the vacuum motor and the brush motor for carbon brush wear. Replace carbon brushes when worn to a length of 10 mm (.375 in) or less.
Contact an Authorized Service Center for machine repairs.
FOR SAFETY: When servicing machine, all repairs must be performed by a qualified service person.
WARNING: Electrical Hazard. Disconnect Battery Cables Before Servicing Machine.

Falcont Ultra B (07- 05)

15

OPERATION
BATTERY MAINTENANCE
WARNING: Fire Or Explosion Hazard. Batteries Emit Hydrogen Gas. Keep Sparks And Open Flame Away. Keep Battery Compartment Open When Charging. FOR SAFETY: When servicing machine, wear protective gloves and eye protection when handling batteries and battery cables. Avoid contact with battery acid. 1. Always follow proper charging instructions (See
CHARGING BATTERIES). 2. Check the electrolyte level (A) in each battery cell
after charging batteries. The level should be approximately 1 cm from the bottom of the fill- port (B). Add distilled water if needed (Figure 26) DO NOT OVERFILL.
B
A

SPECIFIC GRAVITY at 27 C 1.265 1.223 1.185 1.148 1.110

BATTERY CHARGE 100% CHARGED 75% CHARGED 50% CHARGED 25% CHARGED DISCHARGED

NOTE: If the readings are taken when the battery electrolyte is any temperature other than 27_C, the reading must be temperature corrected. Add or subtract to the specific gravity reading 0.004, 4 points, for each 6_C above or below 27_C.
4. Keep battery tops and terminals clean and dry.
To clean batteries:
a. Mix a strong solution of baking soda and water (Figure 28).

FIG. 26
3. Measuring the specific gravity using a hydrometer is a way to determine the charge level, and condition of the batteries (Figure 27). If one or more of the battery cells test lower than the other battery cells (0.050 or more), the cell is damaged, shorted, or is about to fail.

FIG. 28
b. Brush solution sparingly over battery tops, terminal and cable connectors.
NOTE: Do not allow baking soda solution to enter battery cells.
c. Use wire brush to clean terminal post and cable connections.
d. After cleaning, apply a coating of clear battery post protectant to terminals and cable connections.
5. Check for loose or worn cables. Replace if worn.

FIG. 27
NOTE: Do not take readings immediately after adding distilled water. If the water and acid are not thoroughly mixed, the readings may not be accurate. Check the hydrometer readings against the following chart to determine the remaining battery charge level:

16

Falcont Ultra B (07- 05)

OPERATION

TRANSPORTING MACHINE
When transporting the machine by use of trailer or truck, be certain to follow the tie- down procedures below:
FOR SAFETY: When using machine, go slow on inclines and slippery surfaces.
1. Raise the brush/pick-up head.
2. Load the machine using a recommended loading ramp.
3. Position the front of machine up against the front of the trailer or truck. Once the machine is positioned, lower the brush/pick-up head.
4. Place a block behind each wheel to prevent the machine from rolling.
5. Place tie- down straps over the top of machine to prevent it from tipping. It may be necessary to install tie-down brackets to the floor of your trailer or truck.
NOTE: Do not use control grips to secure machine for transporting.
FOR SAFETY: When transporting machine, use a recommended ramp when loading/unloading on/off truck or trailer, use tie- down straps to secure machine to truck or trailer.
STORING MACHINE
1. Charge the batteries before storing. Never store the machine with discharged batteries.
2. Drain and rinse the tanks thoroughly.
3. Store the machine in a dry area with brush base in the up position.
4. Open the recovery tank lid to promote air circulation.
5. If storing machine in freezing temperatures, make sure to drain machine of all water.
ATTENTION: Do not allow machine to freeze without anti freeze. Damage due to freezing temperatures is not covered by warranty.
ATTENTION: Do not expose machine to rain and store indoors.

RECOMMENDED STOCK ITEMS
Refer to the Parts List section in this manual for recommended stock items. Stock Items are clearly identified with a bullet preceding the parts description. See example below:

Falcont Ultra B (07- 05)

17

OPERATION

TROUBLE SHOOTING

PROBLEM No power.

CAUSE Faulty main switch. Batteries need charging. Main circuit breaker is pulled out. Faulty battery(s). Loose battery cable. MAIN circuit breaker has tripped.

Brush motor does not operate.
Vacuum motor does not operate.

Pump switch is not on. Control grips are not rotated. Brush circuit breaker has tripped or is pulled out. Faulty brush motor or wiring. Carbon brushes worn. Loose or broken belt. Faulty vacuum switch. Vacuum motor thermal overload activated.

Faulty vacuum motor or wiring.

Carbon brushes worn.

Drive motor does not operate.

Drive motor circuit breaker has tripped. Faulty speed control board or connection.

Faulty solenoid.

Faulty drive motor.

Faulty wiring.

Worn carbon brushes.

Drive motor operates, but not correctly.

Faulty potentiometer or speed control board.

Loose wire connection.

Uneven or no solution spray. Twist- out spray tips are plugged.

Control grips are not rotated.

Solution line or solution tank filter is clogged.

Inline strainer filter is plugged.

Short run time.

Faulty pump switch. Faulty pump or solenoid. Batteries not fully charged. Bad cell in one or more batteries. Batteries need maintenance. Faulty charger.

SOLUTION Contact Service Center. See Charging Batteries. Depress main circuit breaker. Replace battery(s). Tighten loose cable. Determine cause and reset circuit breaker button. Turn on pump switch. Rotate control grips. Remove obstruction from brush and reset brush circuit breaker button. Contact Service Center. Contact Service Center. Replace, or contact Service Center. Contact Service Center. Remove obstruction and wait 20 minutes for motor to cool. Contact Service Center. Contact Service Center. Determine cause and reset breaker. Contact Service Center. Contact Service Center. Contact Service Center. Contact Service Center. Contact Service Center. Contact Service Center.
Contact Service Center. Remove and clean. Rotate control grips. Remove hose and blow compressed air through it. Flush solution tank after each use. Drain solution tank, remove filter and clean. Located under machine at rear. Contact Service Center. Contact Service Center. Charge batteries. Replace battery. See Battery Maintenance. Replace battery charger.

18

Falcont Ultra B (05- 99)

OPERATION

TROUBLE SHOOTING - Continued

PROBLEM Poor vacuum recovery.

CAUSE Recovery tank is full. Float shut-off screen inside recovery tank is clogged. Pick-up head is clogged with debris. Pick-up head is not sealed to carpet. Faulty actuator. Vacuum hose connections are loose or hose has a hole. Vacuum hose is clogged with debris. Recovery tank inlet hole is obstructed.
Tank gasket is defective. Drain hose plug is loose. Recovery tank lid is loose. Vacuum motor is loose. Battery charge level is low.

SOLUTION Empty recovery tank. Remove screen and clean.
Remove debris, use coat hanger. Adjust pick-up head. Contact Service Center. Push hose cuffs firmly on connections. Replace hose if damaged. Remove clogged debris. Empty recovery tank and tilt tank sideways to access inlet hole, remove obstruction. Replace gasket. Tighten drain plug. Tighten lid. Contact Service Center. Charge batteries. Do not run machine when battery meter is in the red zone.

Falcont Ultra B (05- 99)

19

OPERATION
SPECIFICATIONS
MODEL LENGTH WIDTH HEIGHT WEIGHT SOL./REC TANK CAPACITY SPEED CONTROL CLEANING SPEED (MAX) CLEANING PATH WIDTH PAD PRESSURE SOLUTION PUMP DRIVE SYSTEM BRUSH MOTOR VACUUM MOTOR WATERLIFT BATTERIES RUN TIME PER CHARGE DECIBEL RATING AT OPERATOR'S EAR, INDOORS ON CARPET

Falcont Ultra B
1372 mm (54 in) 762 mm (30 in) 1067 mm (42 in) 170 kg (375 lbs) - w/ batteries 272 kg (600 lbs) 64 L (17 gal) Variable Fwd. / Fixed Reverse 418.05m2 (4,500 sq. ft) per hour 559 mm (22 in) Variable 36- 68Kg (80- 150 lbs) 6.9 bar (100 psi) max., 24V Transaxle, .2 h.p., 24V .2 h.p., 2000 rpm, 24V, 8A, 192W 1 h.p., 2- stage 7.2", 24V, 30A, 720W 2057 mm (81 in) 2- 12V, 225AH Up to 4.5 hours 75dB(A)

20

Falcont Ultra B (06- 14)

MACHINE DIMENSIONS
991 mm (39 in)
762 mm (30 in)

OPERATION
1372 mm (54 in)

Falcont Ultra B (07- 05)

21

ELECTRICAL DIAGRAM

52
ROLL SWITCH

60 WHT

56

4.7K 50K
ADJUSTABLE FORWARD

54

F

70

DIRECTION SWITCH

R

50K

64

LOCKABLE

REVERSE

BLU

72

74

62

ORG

RED 6
VACUUM/ 60 DRIVE AMP CIRCUIT
BREAKER
4 RED
ORG
4 RED

WIRE DIAGRAM

11

BATTERY

BLK

METER

32 GRN

BLK

13

BLK

15

GRN

17

BLK

G

G

G

32

UP

76

58

33

BRN

GRN

16

GRN

38 RED

76

28

35

BLU

82

17 BRN

50

MAIN

24

RED

GRN

BRUSH\ PUMP

30 VACUUM

YEL

16

31

31

DOWN

BLK

ACTUATOR

BLK

RED 38

GRN RED

24 50

33

BLU

58

BRN

HARNESS CONNECTOR

50

RED

44

14

RED

RED

6

RED

14

15 MAIN AMP CIRCUIT
BREAKER

GRN 24
MAIN 66 GRN

GRN

7

BLK

RED

50

24

16
YEL 16
BLK 7

58

BRN

33

BLU

31

38

RED

BLK

31

8

ORG

12 ORG

VACUUM

18

RED

3

BLK

5

BLK

RED

BLU

BRN

33

58

ACTUATOR MOTOR

48

BLU

RED 38 RED 36

BRUSH ROLL SWITCH

18

VACUUM MOTOR

27

BLK

10 DRIVE

RED

BLK

MOTOR RED

ORG

21

20

12

WHT

T1 M2 M1

BLK

60

T2

5

BLU
64 ORG 62

SPEED CONTROL BOARD

GRN

66

4

RED

RED 10

34

CHARGER

CUTOFF

SWITCH

POSITIVE STANDOFF
RED RED

(2) 12 VOLT BATTERIES
24 VDC

+

RED

-

-

BLK

+

BLK 3

NEGATIVE STANDOFF

19

RED 46

BLK

9

BLK

27 BLK

BLK

+-

CHARGER PLUG

RED

36

PUMP

9

BLK

BLU 48

BRUSH

23

BLK

MOTOR

BLU 26

41

BLK

SOLUTION SOLENOID

22

Falcont Ultra B (02- 97)

LADDER DIAGRAM

ELECTRICAL DIAGRAM

RED

CHARGER

CUTOFF

- 34- SWITCH - 10-

- RED-

RED

MASTER CIRCUIT BREAKER
- 1415A RED

- 44- - 50-
RED RED MAIN SWITCH

VACUUM/DRIVE - 4RED 60A
CIRCUIT BREAKER

- 6- RED

(2) 12 VOLT BATTERIES 24 VDC

+

-

BLK

G - 32- - GRN-

- 24- GRN-

MAIN

- 13- - BLK- 11- - BLK-
BATTERY METER
- ORG- - 12-

- 7- - BLK- 20- - RED-

- 8- - ORG-
DIRECTION SWITCH N.C.

- 54- WHT-
F

50K

DRIVE

MOTOR

- 56-

FORWARD - WHT- ROLL

POT

SWITCH

- 52- WHT-

R
- 74- ORG-

REVERSE 50K POT - 64- - BLU-

- 72- ORG-

4.7K
- 70- ORG-

- 21- - BLK-

- 60- WHT-

T1 M2 M1
T2

- 5- BLK-

- 62- ORG-
- 66- - GRN-

SPEED CONTROL BOARD

- 30- - GRN-

- 8- - ORG-

G "VACUUM"

- 16YEL
VACUUM

- 76- GRN-

UP

- 58- - BRN- - BRN-

- BLU-

- 35- BLU-

DOWN ACTUATOR

- 82- BRN-

ACTUATOR MOTOR
- 33- - BLU-
- 31- - BLK- 15- - BLK-

- 17- - BLK- 3- - BLK-

- 18- RED-

- 27- BLK-

VAC MOTOR

"BRUSH/ G PUMP"
- 28- GRN-

- 38- RED-

ROLL SWITCH
- 36- RED-

- 48- BLU-
- 26- BLU-

BRUSH MOTOR

- WHT-

- BLK-

- 23- BLK-

SOLUTION SOLENOID

- 41- BLK-

- 36- RED-

SOLUTION PUMP

- 9- BLK-

Falcont Ultra B (02- 97)

23

PARTS LIST

Before SN 10514502
41 40
42

49 48
47

43
44 45 46

SOLUTION TANK GROUP

Before SN 10227764

2

5

6

7

4

1

17

3

53

49

12

54

13 14 15

19 20 18
21

23 16
24

20 19 22 18
25

28

26
27 55
29

30 28 39 31

9 10

11

50 51 52

Before SN 10227764

8

32 33 34
10 9

Before SN 10183532
36
35 37 38

24

Falcont Ultra B (03- 12)

PARTS LIST

SOLUTION TANK GROUP

REF 1
Y2
Y3
Y4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
27
28 29 30 31

PART # 608518
612518
611068
140706
602529
3701.6
140032
600730
150419 140310 607310 603233 630010 630011 630267 630016 608706 140027 140015 16931 230925 611418 1018155 01683 1012965 1023348 1023712
608417
1035597
150529 607983 608915 1029695

DESCRIPTION
ASM., SOL. TANK COVER GREEN (Before SN 10227764)
COVER, TANK, GREEN (Before SN 10227764)
HINGE, COVER (Before SN 10227764)
RIVET, POP (Before SN 10227764)
SCREEN, FILL (Before SN 10227764)
SCREW, #6X3/8 (Before SN 10227764)
WASHER, FLAT (Before SN 10227764)
DECAL, RECESS (Before SN 10227764) (NO LONGER AVAILABLE) ELBOW, 1/4M X 3/8H 90 CLAMP
HOSE, 3/8" X 17.5"
DECAL, BATTERY DIAGRAM
DGASKET
TUBE, ADAPTER
SPRING, COMP
RING, RETAINING
BRACKET, VAC TUBE
WASHER, FLAT
WASHER, LOCK
SCREW, HEX, M8 X 1.25 X 20, 8.8
SUPPORT, RECOVERY TANK
SLEEVE
SCREW, PAN, M4.8 X 16, SS, TCUT
WASHER, FLAT, #10 SS
DCAP, PORT, SOLUTION FILL
TANK, SOLUTION, GREEN
KIT, TANK, SOLUTION, GREEN (Before SN 10227764)
LABEL [FALCON ULTRA NOBLES] (NO LONGER AVAILABLE)
LABEL, MODEL [NOBLES FALCON ULTRA B]
FITTING, 3/4 HOSE BARB
HOSE, W/LEVEL INDICATORS
CLAMP, HOSE 2 WIRE
CASTER, SWIVEL, 4.0D 1.4W, 4- HOLE [400LB]

QTY. 1
1
1
7
1
2
2
1
2 2 1 1 1 1 1 1 1 3 3 3 1 1 1 1 1 1 1
2
2
2 1 1 2

 ASSEMBLY Y INCLUDED IN ASSEMBLY
D RECOMMENDED STOCK ITEMS

REF 32 33 34 35 36 37 38 39 40 41 42 43
44
45 46 47
48 49 50 51 52 53 54 55

PART # 140027 140015 09740 600476 621324 140011 140350 608184 578301 140826 621443 605061
605062
07514 578201000
606146
140032 140826 1020193 140032 140826 1060173 41578 1034637

DESCRIPTION

QTY.

WASHER, FLAT, 0.35B 0.75D .04 SS 8

WASHER, LOCK, SPLT, 0.31 SS

8

SCREW, HEX, M8 X 1.25 X 20, SS

8

STRAP, PLUG

1

(Before SN 10183532)

DPLUG, EXPANSION

1

(Before SN 10183532)

WASHER, FLAT

1

(Before SN 10183532)

SCREW, #10X1/2

1

(Before SN 10183532)

LABEL, LOGO, 09.3L 2COLOR

1

(NO LONGER AVAILABLE)

DKNOB, RND (Before SN 10514502) 1

SCREW, PAN, #6- 32X0.75, PHL SS 1 (Before SN 10514502)

DCHAIN, BALL, #10X157L, SS

1

(Before SN 10514502)

DCOVER, SOLUTON FILL

1

(Before SN 10514502)

(REPLACED BY 1060173)

DGASKET, COVER, SOLUTION FILL 1 (Before SN 10514502)
(REPLACED BY 1060173)

WASHER, LOCK, INT, #10 SS

1

(Before SN 10514502)

SCREW, PAN, #10- 32X0.50, PHL

1

(Before SN 10514502)

DFILTER, SCREEN, SOL- FILL

1

(Before SN 10514502)

(REPLACED BY 1060173)

WASHER, #6 FLAT SS

2

SCREW, PAN, #6- 32X0.75, PHL SS 2

SHIELD, LIGHT

1

WASHER, FLAT, #6 SS

2

SCREW, PAN, #06- 32 X 0.75, SS

2

PHL SHTMTL

DCOVER ASSY, TANK, SOLTN FILL 2 (AFTER SN 10514502)

WASHER, FLAT, 06, SS

2

(AFTER SN 10514502)

LABEL, FRONT 3.50 [NOBLES

1

ICON]

Falcont Ultra B (03- 12)

25

PARTS LIST

RECOVERY TANK GROUP (S/N 10430222-

)

7

5

69

10

11

12

8
2 1
3 4

9 14

13 17 16 15

18

19 20 21

15

36

16 17

17 16 15

33 34
26

27
28 37

24 23
25

29

22

30

31

32
33 34 35

26 Falcont Ultra B (03- 12)

PARTS LIST

RECOVERY TANK GROUP (S/N 10430222-

)

REF 1 Y2
3 4 5 6 Y7 Y8 9 10 11 12  13 Y 14
15 16 17 18 19 20 21

PART # 701103 606088 101714 210240 180613 100102 100105 100109 140826 3701.6 230513 120906 614373 1026386
578187000 140052 140000 140960 140027 140015 16931

DESCRIPTION ASM.,STANDPIPE NIPPLE DGASKET NUT, FLANGED DFLOAT, SHUTOFF DASM.,LID CLEAR W/STD HOLE DLID, CENTER CLEAR ONLY DLID, OUTER RING ONLY SCREW, #6X3/4 SCREW, #6X3/8 ASM., CHAIN DECAL, IMPORTANT DRAIN TANK, REC, GREEN W/LABEL LABEL, WARNING [EXPL, FIRE, SHK EN/FR/ES] SCREW, M06X12MM WASHER, LOCK WASHER, FLAT CABLE, SUPPORT WASHER, FLAT WASHER, LOCK SCREW, HEX, M8 X 1.25 X 20, 8.8

 ASSEMBLY Y INCLUDED IN ASSEMBLY
D RECOMMENDED STOCK ITEMS

QTY. 1 1 1 1 1 1 1 1 7 1 1 1 1 1
12 12 12 1 1 1 1

REF  22 Y 23 YY24 YY25
26 27 28  29 Y 30
31 32 33 34 35 36 37

PART # 1010143 1008639 1019563 1008637 614157 604137 100038 130397 1073334
100143 1055851 140000
08712 140340 600311 130192

DESCRIPTION

QTY.

DHOSE, DRAIN, ASSY, 1.5D X

1

32.3L, BLK

DASM., CAP, DRAIN HOSE

1

DSTRAP, DRAIN CAP

1

DO RING, 1.48" ID, 1.76" OD

1

CLAMP, HOSE, WORMDRIVE,

1

1.06- 2.00D, .50W

SCREW, STUD, M6 X 1.00 X 127, PL 3 (AFTER SN 10430222)

DGASKET, .50, 02.63ID 05.75OD,

1

ADH (AFTER SN 10430222)

DFAN, VACUUM, 5.7D, 024VDC, 3

1

STAGE [(AFTER SN 10430222)

DBRUSH, CARBON, MOTOR, ELE

1

[1PICK=1PKG] (1PKG=2 BRUSHES)

(AFTER SN 10430222)

DGASKET, MOTOR, VACUUM, 5.7

1

(AFTER SN 10430222)

PLATE, MOUNT, MOTOR

1

(AFTER SN 10430222)

WASHER, FLAT, 0.28B 0.62D .04 SS 3 (AFTER SN 10430222)

NUT, HEX, LOCK, M6 X 1.00, NL, SS 3 (AFTER SN 10430222)

SCREW, PAN, PHL, 10- 24 X 0.62,

4

SS (AFTER SN 10430222)

DHINGE, RECOVERY TANK

1

TERMINAL, MAL .25 12- 10GA YEL, 2 F- INS

Falcont Ultra B (06- 14)

27

PARTS LIST
RECOVERY TANK GROUP (S/N 00000000- 10430221)

2 1
3 4

5 69
8

15

36

16 17

17 16
15 29

30 32 34
28

7

10

12

11

9 14

13 17 16 15

18

19 20 21
24 23
25

27
28 35
32 31
33

22 37
26 Falcont Ultra B (03- 12)

PARTS LIST

RECOVERY TANK GROUP (S/N 00000000- 10430221)

REF 1 Y2
3 4 5 6 Y7 Y8 9 10 11 12  13 Y 14
15 16 17 18 19 20 21

PART # 701103 606088 101714 210240 180613 100102 100105 100109 140826 3701.6 230513 120906 614373 1026386
578187000 140052 140000 140960 140027 140015 16931

DESCRIPTION ASM.,STANDPIPE NIPPLE DGASKET NUT, FLANGED DFLOAT, SHUTOFF DASM.,LID CLEAR W/STD HOLE DLID, CENTER CLEAR ONLY DLID, OUTER RING ONLY SCREW, #6X3/4 SCREW, #6X3/8 ASM., CHAIN DECAL, IMPORTANT DRAIN TANK, REC, GREEN W/LABEL LABEL, WARNING [EXPL, FIRE, SHK EN/FR/ES] SCREW, M06X12MM WASHER, LOCK WASHER, FLAT CABLE, SUPPORT WASHER, FLAT WASHER, LOCK SCREW, HEX, M8 X 1.25 X 20, 8.8

 ASSEMBLY Y INCLUDED IN ASSEMBLY
D RECOMMENDED STOCK ITEMS

QTY. 1 1 1 1 1 1 1 1 7 1 1 1 1 1
12 12 12 1 1 1 1

REF  22 Y 23 YY24 YY25
26 27 28 29 30
31 32 33 34 35 36 37

PART # 1010143 1008639 1019563 1008637 614157 100001 019686055 603963 602656
604403 140000 06944 58979 130192 600311
N/A

DESCRIPTION
DHOSE, DRAIN, ASSY, 1.5D X 32.3L, BLK
DASM., CAP, DRAIN HOSE
DSTRAP, DRAIN CAP
DO RING, 1.48" ID, 1.76" OD
CLAMP, HOSE, WORMDRIVE, 1.06- 2.00D, .50W
DGASKET, VAC MOTOR (BEFORE SN 10430222)
SPACER 6.5X15.8X6.4 (BEFORE SN 10430222)
SPACER 6.5X12.7X41.2 (BEFORE SN 10430222)
DMOTOR, VAC 7.2 2 STG 24 VDC (BEFORE SN 10430222) (REPLACED BY 9006571)
CARBON BRUSH, SET OF 2 (BEFORE SN 10430222)
WASHER, FLAT (BEFORE SN 10430222)
SCREW, HEX, M6 X 1.00 X 25, 8.8 (BEFORE SN 10430222)
SCREW, HEX, M6 X 1.00 X 55, FL (BEFORE SN 10430222)
TERMINAL, MALE 1/4 #10 12- 10
DHINGE, RECOVERY TANK
DRAIN HOSE ASSEMBLY (REPLACED BY 1010143 ITEM #22)

QTY. 1 1 1 1 1 1 1 2 1
1 3 1 2 2 1 1

Falcont Ultra B (03- 12)

29

PARTS LIST

CONSOLE GROUP

1
10 2
5
6

8 9

38 40 46 36
46 18 30
50

37 34

7
33 42
3

36 35
45 32 31
29 27
54

48 16
21

41

11

38 47
15 14

17

35 4
49

51

55

39

52

53

13 12
43 41

12 1

51 52 53 24
Replaced By 1066506
30

28

26

19

23

44

25

20

24

22 Falcont Ultra B (07- 13)

PARTS LIST

CONSOLE GROUP

REF 1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28

PART # 1066506 605351 604402 605321 578141000
07514 602978 602919 601107 606020 630104 02850 630261 630128 608299 601108 130753 08712 140045 140351 630304 230715 230649 230710 140415 140155 606550 603007

DESCRIPTION GRIP, HANDLE, RND BUSHING HANDLE, TUBE CABLE TIE SCREW, M5X10MM WASHER, LOCK, INT, 10, SS PANEL, CONTROL W/SILKSCREEN DSWITCH, DPDT ON/ON DSWITCH, LIGHTED ROCKER METER, BATTERY VOLTAGE 24V DSPEED CONTROL, PMB, 55 AMP NUT, HEX, LOCK, M4 X 0.70, NL SPACER HEAT SINK HOUSING, CONTROL, GREEN DSWITCH, TOGGLE BOOT, SWITCH NUT, HEX, LOCK, M6 X 1.00, NL, SS WASHER, FLAT SCREW, M12X1.75X70MM SCREW, M4X35MM TUBE, HANDLE ADJUSTMENT PIN, HANDLE ADJUSTMENT PIN, HANDLE LOCK SPRING, LOCK PIN BUSHING KNOB, SPEED CONTROL BUSHING, SNAP

QTY. 2 1 1 1 4 4 1 1 3 1 1 4 2 1 1 1 1 2 2 2 2 1 2 2 1 2 1 1

 ASSEMBLY Y INCLUDED IN ASSEMBLY
D RECOMMENDED STOCK ITEMS

REF 29 30 31 32 33 34 35 36

PART # 602886 605812 140830 140019 27098 614003 140552 19066

37 38 39 40  41 Y 42 Y 43 44 45 46 47 48 49 50 51 52 53 54 55

25671 140890 140900 608322 602873 130776 130775 140024 603830 140000 605094 140859 230661 611979 140027 140015 16931 606549 613092 604486

DESCRIPTION PIN, SPRING RETURN SPRING, EXPANSION SCREW 6- 32X1- 5/8 WASHER, LOCK BRACKET, SWITCH DSWITCH, SNAP ACTION W/BUMP NUT WASHER, FLAT, 0.25B 0.56D .05, PL, 10 MOUNT, SWITCH SCREW. 10- 24X1/2 SCREW 10- 24X3/4 SCREW, M6X1.0X16MM HARNESS, CONSOLE W/POTS DPOTENTIOMETER, 50K DPOTENTIOMETER, 50K LOCKABLE WASHER, LOCK PLATE, GUARD SWITCH WASHER, 1/4 FLAT COLLAR, HANDLE SCREW, 1/4 SK PLATE, LOCK CONTROL HOUSING WELDMENT, DRAIN HOSE WASHER, FLAT WASHER, LOCK SCREW, HEX, M8 X 1.25 X 20, 8.8 DECAL, SPEED CONTROL DHARNESS, WIRE MAIN ASM., DIODE SPLICED

QTY. 1 1 2 2 1 2 2 2
1 2 1 2 1 1 1 2 1 4 2 2 2 1 4 4 4 1 1 1

Falcont Ultra B (07- 13)

31

PARTS LIST

CONTROL PANEL GROUP

1

18

13 8

12

10

7

11

8

12

9 10

9

13 11

16

35
34 30

37 36

17 19
20 21
22 23 24 25
26 27
29 28

28

32

30 31
33

30 31

32

2

3

6

5

4

14 15

Falcont Ultra B (07- 05)

PARTS LIST

CONTROL PANEL GROUP

REF 1 2 3 4 5 6 7 8 9
10  11 Y 12
13 14 15 16 17 18 19

PART # 602559 609969 069764626 130161 130175 582150 604486 608322 140284 140000 606404 281001009 605905 578141000 140018 603487 130739 605823 140829

DESCRIPTION PANEL, CONTROL HOUSING PLUG, HOUR METER PLUG, HOLE 012.7 PLUG, DOME .875 PLUG, DOME .750 PLUG, ACCESSORY SWITCH DIODE, ASSY SPLICED SCREW, M6X1.0X20MM NUT WASHER, FLAT DASM., DIODE W/RING TERM. RING, TERMINAL #10 DSOLENOID, 24V SCREW M5X10 PANPHL WASHER #10 INT DCIRCUITBREAKER, 15.0A BRUSH DCIRCUITBREAKER, 60AMP O RING .926ID X .996OD SCREW, 6- 32X1

 ASSEMBLY Y INCLUDED IN ASSEMBLY
D RECOMMENDED STOCK ITEMS

QTY. 1 1 1 1 1 2 1 6 4 4 2 4 2 4 4 1 1 1 2

REF 20 21 22 23 24 25 26 27 28
29 30 31 32 33 34 35 36

PART # 140019 605387 603331 578403000 601359 600437 603191 579211 76062
602871 140016 01697 140539 603192 140553 130698 140018

DESCRIPTION WASHER, LOCK CONNECTOR, 50A WO/CONTACTS SPACER, CHARGER PLUG SCREW, M3X20MM PLATE, SWITCH BACKING DSWITCH, ROLLER BRACKET, CHGR W/STANDOFF NUT, LOCK INSULATOR, PANEL & SWITCHBOARD CABLE, BATTERY #6 BLACKX24" WASHER, LOCK SCREW, HEX, .25- 20 X 0.62, SS NUT ASM., WIRE #6X650MM RED SCREW, 1/4- 20X1/2 BUSHING, SNAP WASHER, #10 INT

QTY. 2 1 1 2 1 1 1 2 2
1 4 2 2 1 2 1 2

Falcont Ultra B (03- 12)

33

PARTS LIST

48 22

26 25 22 24

2 10

22 24

26 25 22 43 46 7 33

7

47

8

9

7

8

9

LIFT GROUP

11 1

42

21

15

7

22

41

24

44 15
14

8 9 11 7 3 4
5
6 21
22

12

15

14

16

13 17
19 20

23
24 22 25 26
27 28
49 47

18 19 20

27

28

29

28 31

28 31

32

45

34

40

35

36

37 30

38

39

27

34

Falcont Ultra B (07- 05)

PARTS LIST

LIFT GROUP

REF

PART # DESCRIPTION

1 612782 PLATE, BASE TRANSAXLE

2 140236 SCREW, 1/2- 13X1 1/4

3 140028 WASHER, FLAT

4 140333 WASHER, LOCK

5 09291 SCREW, HEX, M10 X 1.5 X 20

6 1002936 BRACKET, ACTUATOR

7 140027 WASHER, FLAT

8 140015 WASHER, LOCK

9 16931 SCREW, HEX, M8 X 1.25 X 20, 8.8

10 590248 SCREW, 38- 16X4.75

11 160486 DCUFF, HOSE

12 160426 DHOSE, VAC 1.5X15" W/CUFF

13 603084 BRACKET, VAC HOSE

14 140000 WASHER, FLAT

15 140016 WASHER, LOCK

16 48732 SCREW, PAN, PHL, M6 X 1.00 X 10

17 130129 TERMINAL, FM DSCNT 22- 18 RED

18 600952 DACTUATOR, 24VDC

19 604076 PIN, CLEVIS

20 578421 PIN, COTTER

21 02931 NUT, HEX, LOCK, .50- 13, NL, SS

22 140045 WASHER, FLAT

23 602567 BRACKET, SPRING

24 602882 BUSHING

25 140024 WASHER, LOCK

D RECOMMENDED STOCK ITEMS

QTY. 1 2 2 2 2 1 16 8 8 2 1 1 1 2 10 2 2 1 2 2 3 17 1 8 6

REF 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49

PART # 09745 140564 140036 603044 140027 140546 612781 602977 602565 140221 140220 140015 600306 603046 160613 600307 140226 140139 15678 603093 630477 59156 36758 140046

DESCRIPTION SCREW, HEX, M12 X 1.75 X 25, SS BOLT, SHOULDER 3/8X3/4 WASHER, FLAT PLATE, ACTUATOR LIFT WASHER, FLAT NUT, NYLOCK LIFT BRACKET, EXTRACTOR BRACKET, MOUNT CARPET TOOL SPRING, CARPET TOOL SCREW, 5/16- 18X1 1/4 SCREW, 5/16- 18X2 1/2 WASHER, LOCK TOOL, CARPET 22" BRACKET, BASE LEVELER DHOSE, VAC 1.5X30" W/CUFFS BRACKET, MOUNT EXTRACTOR SCREW, 5/16- 18X5/8 SLEEVE SCREW, HEX, M6 X 1.00 X 16, SS BRACKET, BUMPER WHEEL WHEEL, 2" GRAY NUT, HEX, LOCK, .38- 16, NL, SS BOLT, SHOULDER WASHER, 1.00X.392X.090

QTY. 6 4 6 1 2 2 1 1 1 2 2 4 1 1 1 1 4 2 4 1 8 4 2 2

Falcont Ultra B (03- 12)

35

PARTS LIST

DRIVE GROUP

16 15

14

11
20 19 18 17
Before SN 10492843
12
13 12
Replaced By 1063591

7

21

10

9

8

1

6

5 4
21 10

3 2
14 15 16

20
19 18 17

36

Falcont Ultra B (03- 12)

PARTS LIST

DRIVE GROUP

REF  Y1 Y 2
YY 3
YY 4 YY 5 YY 6 YY 7 YY 8 YY 9 Y 10

PART # 1013312 612873 614165
612877
614166
612883
612874 612875 577031000
N/A 32982 33951 612880

DESCRIPTION

QTY.

TRANSAXLE, 24V MOTOR, 116RPM 1

TRANSAXLE, REPLMT,

1

BODY ONLY

DMOTOR, ELE, 24VDC

1

TRANSAXLE REPLMNT KIT

(After SN 10170826)

DMOTOR, REPLMT, 24V- 612844

1

TRANSAXLE

(Before SN 10170826)

(REPLACED BY 614165)

DKIT, BRUSH CARBON QTY (4)

1

(After SN 10170826)

(FOR MOTOR #614165)

DKIT, BRUSH CARBON QTY (2)

1

(Before SN 10170826)

(FOR MOTOR #612877)

COUPLING, TRANSAXLE REPLMT 1

KEY, SPECIAL, TRANSAXLE

1

REPLMT

SCREW, #8X1/2 PANPHL ZN

2

COVER, SHAFT

2

WASHER, LOCK, INT, 0.25

2

SCREW, SOC, .25- 20 X 0.62, BO

2

SLEEVE, TRANSAXLE REPLMT

2

 ASSEMBLY Y INCLUDED IN ASSEMBLY
D RECOMMENDED STOCK ITEMS

REF Y 11
12
13
14 15 16 17 18 19 20 21 N/S

PART # 1063591
1043275
612879
607452 140000 41169 612255000 140333 140028 612784 612783 130041

DESCRIPTION
RETAINER, HUB, TRANSAXLE WHEEL (After SN 10492843) (KIT INCLUDES 1 EACH - HUB, CLEVIS PIN & COTTER PIN)
BOLT KIT, TRANSAXLE (Before SN 10492843) (REPLACED BY 1063591)
HUB, WHEEL, TRANSAXLE RPLMT (Before SN 10492843) (REPLACED BY 1063591)
WHEEL, 8.0D 2.00W TPR
WASHER, 1/4 FLAT
NUT, HEX, LOCK, .25- 20 NL, SS
SCREW, M10X35MM
WASHER, LOCK M10
WASHER, 3/8 FLAT
BRACKET, MTG, TRANSAXLE, YEL PL [UNIVSL]
SPACER, AXLE
WIRE TIE, NYLON

QTY. 2
2
2
2 8 8 4 4 4 2 4 2

Falcont Ultra B (03- 12)

37

PARTS LIST

BRUSH BASE GROUP
1

2

23 17

7

8

9 10

11
12 16

20

13

14 18

15

3

19

24

22

21

6
38

4 5
Falcont Ultra B (03- 12)

PARTS LIST

BRUSH BASE GROUP

REF 1 2 3 4 5 6
 Y7 Y8 Y9 Y 10 Y 11 Y 12

PART # 603193 101106 200315016 100157 611919 140197 700422 240063 24672 100049 140125 230261 100005

DESCRIPTION CORD, 16/2X33 SJT BASE, 22" WASHER, FLAT GASKET, BASE PLATE PLATE, BASE SCREW, 10- 24X3/8 TRSPHL DASM., BRUSH BRUSH, CYLINDER SCREW, HEX, .25- 20 X 0.75, SS SEAL, BRUSH BEARING BEARING, BRUSH BLOCK, BEARING GASKET, BEARING BLOCK

 ASSEMBLY Y INCLUDED IN ASSEMBLY
D RECOMMENDED STOCK ITEMS

QTY. 1 1 1 1 1 11 1 1 4 2 2 2 1

REF Y 13 Y 14 Y 15 Y 16
17 18 19 20 21 22 23 24

PART # 230408 140548 230406 140859 130096 230411 140518 602965 230410 230409 130154 140859

DESCRIPTION PULLEY, BRUSH NUT 5/16 SHAFT, BRUSH 22" SCREW, SET 1/4- 20X1/4 TERMINAL, MALE DSCNT 16- 14 BRACKET, BRUSH MOTOR NUT, KEP 10- 32 DMOTOR, BRUSH DRIVE 24 VDC DPULLEY, MOTOR DBELT, TIMING DOME PLUG SCREW, SET 1/4- 20X1/4

QTY. 1 1 1 1 2 1 2 1 1 1 1 1

Falcont Ultra B (03- 12)

39

PARTS LIST

5
4 3 2 1
D

30 31
32

34 33

35
44 36 A
39 38
40

SOLUTION GROUP

B9 6
10

11

7

17

12

8

13

14

21

26

2

25 24

1 23

87 D

22 19 20

37 10

29 9

27 C
28

15 16
18 19 20
C

B

Before SN 10128570
46

43

45

47 48

41 42

44

A

36

50 51

49

A

36

40

Falcont Ultra B (07- 05)

PARTS LIST

SOLUTION GROUP

REF 1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18 19 20 21 22 23  Y 24 Y 25 Y 26 Y 27

PART # 607704 140310 150516 140058 603063 150933 140016 578187000 607705 630369 150517 150706 150615 607473 140801 140023 603055 150515 140325 607706 605394 150520 150915 700423 150921 150422 230407 150208

DESCRIPTION HOSE, 3/8" X 24.5" CLAMP, HOSE FITTING, 1/4MX3/8H BARB WASHER BRACKET, QC MOUNT PLUG, QUICK COUPLER WASHER, LOCK SCREW, M06X12MM HOSE, 1/2" X 24" RED CLAMP, HOSE FITTING, 1/4MX1/2H BARB FITTING, TEE NIPPLE, 1/4 CLOSE DSOLENOID, WATER 24 VDC SCREW, 8- 32X3/8 WASHER, LOCK BRACKET, SOLENOID FITTING, 4H BARB CLAMP HOSE, 1/4" X18" FITTING, 1/4MX3/8H BARB 45 FITTING, 1/8FX1/4H BARB COUPLER, QUICK ASM., SPRAY BAR PLUG, QUICK COUPLER FITTING, 1/8MX1/8F ELB STRT 45 MANIFOLD, SPRAYBAR 22" PLUG

 ASSEMBLY Y INCLUDED IN ASSEMBLY
D RECOMMENDED STOCK ITEMS

QTY. 1 2 1 2 1 1 4 4 1 2 1 1 1 1 2 2 1 1 2 1 1 1 1 1 1 1 1 2

REF Y 28 YY 29
30 31 32 33 34 35 36 37 

PART # 201011 201013 201015 140899 140012 603031 140552 130096 150412 607305 150425 613981

Y 38 Y 39 Y 40

150107 1043095 150617

Y 41 YY42

1007428 180638

Y 43 Y 44
45 46 47 48 49  50 Y 51

150412 607775 150101 150403 150302 150415 54333 180619 180638

DESCRIPTION DNOZZLE, TWISTOUT (80015) DTIP, REPLACEMENT FOR #80015 DSEAL, SPRAY NOZZLE SCREW, 10- 24X1 1/4 WASHER, FLAT DPUMP, SOL, ELE, 24VDC 100PSI NUT, NYLOCK TERMINAL, MALE .25 FITTING. 3/8MX3/8H ELBOW 90_ TUBING, 3/8" X 30" GRAY VINYL FITTING, 3/8MX1/2H ELBOW 90 KIT, REPLMT, FILTER, LARGE ID (Before SN 10128570)
FITTING, BRS, STR, PM08/PF06 FITTING, BRS, E45, PF06/PM06 FITTING, BRS, STR, PM06 HEX NIPPLE, T
DFILTER, BOWL & SCREEN DFILTER, SCREEN, 125MESH NY, SLEEVE
FITTING, PLSTC, E90, PM06/BM06 CLAMP, HOSE .63- .66 2 WIRE BLK FITTING, BUSHING ELBOW, STREET 1/4X45 COUPLING, 1/4FX1/4F FITTING, 1/4MX3/8H ELBOW 90_ CLAMP, HOSE DFILTER, 1/4 NPT CLEAR BOWL DFILTER, SCREEN, 125MESH NY, SLEEVE

QTY. 6 1 1 2 2 1 2 2 1 1 1 1
1 1 1
1 1
1 2 1 1 1 1 2 1 1

Falcont Ultra B (03- 12)

41

PARTS LIST

PUMP BREAKDOWN GROUP

2
3 4 5
6 1

REF 1 Y2
Y3

PART # 603031 190129 190172 190134 190128 190124

DESCRIPTION DPUMP, SOL, ELE, 24VDC 100PSI DKIT, PUMP PRESSURE SWITCH DKIT, PUMP PRS SWITCH (VITON) DKIT, PUMP DIAPHRAGM ONLY DKIT, PUMP UPPER HOUSING DKIT, PUMP CHECK VALVE ONLY

 ASSEMBLY Y INCLUDED IN ASSEMBLY
D RECOMMENDED STOCK ITEMS

QTY. 1 1 1 1 1 1

REF Y4 Y5 Y6

PART # 190171 190131 190130

DESCRIPTION DKIT, PUMP VALVE (VITON) DKIT, PUMP SERVICE DKIT, PUMP LOWER HOUSING

QTY. 1 1 1

42

Falcont Ultra B (07- 05)

1
2 3

BATTERY AND CHARGER GROUP
5 5

2

5

2

2 4

PARTS LIST

6

10 7 8

11 9
12

REF 1 2 3 4 5 6
7

PART # 602871 45962 603192 130364 611221 1070591
601991

DESCRIPTION CABLE, BATTERY #6 BLACKX24" COVER, BATTERY TERMINAL ASM., WIRE #6X650MM RED CABLE, BATTERY #6 BLACKX15" DBOOT, BATTERY CABLE BLK DBATTERY, WET, 12VDC 0225AH, W/ CARTON DTRAY, BATTERY

 ASSEMBLY Y INCLUDED IN ASSEMBLY
D RECOMMENDED STOCK ITEMS

QTY. 1 4 1 1 4 2
1

Falcont Ultra B (07- 13)

REF 8 9
 10
Y 11
Y 12

PART # 602592 603828 1029256
605387
1017079

DESCRIPTION
SUPPORT TUBE BATTERY
DECAL, BATTERY PLACEMENT
DCHARGER 24VDC, 19A VAR VAC 1PH 50/60HZ
CONNECTOR, ANDERSON, 50A, RED W/O CONTACT
CORD, EXTN, 16GA /3, 010FT

QTY. 1 1 1
1
1

43

OPTIONS

WAND GROUP, LOW PRESSURE, 13 in / 330 mm

4 5

6

1

7

15

17 2

8 10
11 9
12
13 14
16

3
44

17
18 19 20
21 22
23 24
25 26
Falcont Ultra B (07- 07)

OPTIONS

WAND GROUP, LOW PRESSURE, 13 in / 330 mm

REF 
Y1 Y2 Y3 Y 4 YY 5 YY 6 YY 7 Y8 Y9 Y 10 Y 11 Y 12 Y 13 Y 14

PART # 600048
200403.BK 120846 200939 200927 01697 200912 140834 200809 200902 140605 140520 150403 150913 150615

DESCRIPTION DTOOL, 330MM (13 IN) FLOOR LP SER 60 TOOL, FLOOR BLACK DECAL, LOW PRESSURE TOOL DSHOE, 330MM (13 IN) FLR TOOL DGRIP, HAND ADJ. COMPLETE SCREW, HEX .25- 20 X 0.62 DGRIP, HANDLE FOAM SCREW, FLT .25- 20 X 0.62 PHL SLEEVE, HANDLE FLOOR TOOL HANDLE, IMPERIAL VALVE PIN, HANDLE IMPERIAL NUT, 1/4 PUSH BLK FITTING, BRS E45 PM04/PF04 DFITTING, BRS QDC PF04 SER 60 FITTING, BRS STR PM04 CLOSE

 ASSEMBLY Y INCLUDED IN ASSEMBLY
D RECOMMENDED STOCK ITEMS

QTY. 1
1 1 2 1 2 1 2 1 1 1 2 1 1 1

REF Y 15 YY16 Y 17 Y 18 Y 19 Y YY20 YY21 YY22 YY23 Y 24 Y 25 Y 26 N/S

PART # 210150 190603 160170 150606 140058 700062 150700 150600 150401 200993 200996 200964 200994 200170

DESCRIPTION DVALVE, FLOW CONTROL PF04 DKIT, REPAIR IMPERIAL WAND, HOSE ASSEMBLY 46" FITTING, BRS STR PM04 HEX NIP WASHER, .54B X .88D X .06 WAND ASM., SPRAYBAR WO/TIPS FITTING, BRS TEE PF04 CROSS FITTING, 1/4MX2" NIPPLE BRS FITTING, BRS E90 PF04/PF04 SPRAY BODY, 1/4" MALE BRASS DFILTER, SCREEN 100 MESH DFITTING, TIP 11003 T- JET BRS DCAP, NOZZLE SPRAY (8002) SQUEEGEE ASSY, 380MM/15.0, COMPLT (OPTION - FOR HARD FLOOR SURFACES)

QTY. 1 1 1 1 1 1 1 2 2 3 3 3 3 1

Falcont Ultra B (03- 12)

45

OPTIONS

WAND GROUP, LOW PRESSURE, 16 in / 406 mm

4 5

6

1

7

15

17 2

8

10

9

11

12

13 14
16

17

18

19

20 21

22

3

23

24
25 26 27

46

Falcont Ultra B (07- 07)

OPTIONS

WAND GROUP, LOW PRESSURE, 16 in / 406 mm

REF 
Y1 Y2 Y3 Y 4 YY 5 YY 6 YY 7 Y8 Y9 Y 10 Y 11 Y 12 Y 13 Y 14

PART # 200503
200411.BK 120846 200956 200927 01697 200912 140834 200809 200902 140605 140520 150403 150913 150615

DESCRIPTION DTOOL, 406MM (16 IN) FLOOR LP SER 60 TOOL, FLOOR 406MM (16 IN) DECAL, LOW PRESSURE TOOL DSHOE, 406MM (16 IN) FLR TOOL DGRIP, HAND ADJ. COMPLETE SCREW, HEX .25- 20 X 0.62 DGRIP, HANDLE FOAM SCREW, FLT .25- 20 X 0.62 PHL SLEEVE, HANDLE FLOOR TOOL HANDLE, IMPERIAL VALVE PIN, HANDLE IMPERIAL NUT, 1/4 PUSH BLK FITTING, BRS E45 PM04/PF04 DFITTING, BRS QDC PF04 SER 60 FITTING, BRS STR PM04 CLOSE

 ASSEMBLY Y INCLUDED IN ASSEMBLY
D RECOMMENDED STOCK ITEMS

QTY. 1
1 1 2 1 2 1 2 1 1 1 2 1 1 1

REF Y 15 YY16 Y 17 Y 18 Y 19 Y YY20 YY21
YY22 YY23 YY24 Y 25 Y 26 Y 27

PART # 210150 190603 160170 150606 140058 700656 150706 150709
150600 150401 200993 200996 200964 200994

DESCRIPTION DVALVE, FLOW CONTROL PF04 DKIT, REPAIR IMPERIAL WAND, HOSE ASSEMBLY 46" FITTING, BRS STR PM04 HEX NIP WASHER, .54B X .88D X .06 WAND ASM., SPRAYBAR 16" WO/TIPS FITTING, BRS TEE PF04 FITTING, BRS TEE PM04/PF04/PF04 FITTING, 1/4MX2" NIPPLE BRS FITTING, BRS E90 PF04/PF04 SPRAY BODY, 1/4" MALE BRASS DFILTER, SCREEN 100 MESH DFITTING, TIP 11003 T- JET BRS CAP, NOZZLE SPRAY (8002)

QTY. 1 1 1 1 1 1 1 2
2 2 4 4 4 4

Falcont Ultra B (03- 12)

47

OPTIONS

HAND TOOL, 5 in / 127 mm
6 1
5 3

2 3

REF  Y1 Y2 Y3 Y4 Y5 Y6

PART # 200505 200431.BK 150913 150606 200905 210210 190600

DESCRIPTION DASM., HAND TOOL 5" SERIES 60 TOOL, HAND BLACK FITTING, BRS QDC PF04 SER60 FITTING, BRS STR PF04 HEX NIP LEVER, K- VALVE W/PIN DVALVE, FLOW CONTROL 04PF KIT, K- VALVE REPAIR

QTY. 1 1 1 2 1 1 1

4 8
7 9
10 11 12

REF Y7 Y8 Y9 Y 10 Y 11 Y 12

PART # 140609 150403 200992 200996 200965 200994

DESCRIPTION PIN, ROLL 0.187D X 0.56L FITTING, BRS E45 PF04/PF04 FITTING, BRS STR PF02 SWIVEL FILTER, SCREEN 100MESH DFITTING, BRS TIP, 8002 T- JET CAP, NOZZLE SPRAY (8002)

QTY. 1 1 1 1 1 1

HAND TOOL, CREVICE, 3 in / 76 mm

1
7 6 5

23 4

REF  Y1 Y2 Y3

PART # 200517 200436.BK 200975 210014

DESCRIPTION DTOOL, CREVICE LP/HP SER 60 TOOL, CREVICE BLACK DFITTING, BRS TIP #5002 1/8V- JET DVALVE, TOGGLE 02PF W/NUT

QTY. 1 1 1 1

 ASSEMBLY Y INCLUDED IN ASSEMBLY
D RECOMMENDED STOCK ITEMS

REF Y4 Y5 Y6 Y7

PART # 210020 160106 150100 150913

DESCRIPTION POSITIONER, VALVE HANDLE HOSE, SOLUTION CREVICE TOOL FITTING, BRS STR PM04/PF02 FITTING, BRS QDC PF04 SER 60

QTY. 1 1 1 1

48

Falcont Ultra B (07- 07)

HAND TOOL, UPHOLSTERY, LOW PRESSURE

1 2

3

54

8

9

OPTIONS

7

6

12

10

REF  Y1 Y2 Y3 Y4 Y5 Y6 Y7

PART # 200540 200845 200843 190631 210226 200991 200838 200840

DESCRIPTION DTOOL, UPHOLSTERY LP SER 60 COVER, UPHOLSTERY TOOL GASKET, COVER DKIT, SERVICE LP UPHOLSTERY DVALVE, WATER/SOL 120VAC LP DFITTING, SS TIP 1/8K- JET SCREW, #06- 32 X 0.75 TRIGGER, UPHOLSTERY TOOL

 ASSEMBLY Y INCLUDED IN ASSEMBLY
D RECOMMENDED STOCK ITEMS

QTY. 1 1 1 1 1 1 4 1

11 13 14

REF Y8
Y9 Y 10 Y 11 Y 12 Y 13 Y 14

PART # 200844
200837 200848 200842 200841 150606 150913

DESCRIPTION DHOSE, VAC UPHOLSTERY TOOL W/O CUFFS DHOSE, UPHOLSTERY TOOL FITTING, BRASS (3 PCS) FILTER, INLINE COMPLETE SCREEN ONLY, INLINE FILTER FITTING, BRS STR PM04 HEX NIP DFITTING , BRS QDC PF04 SER 60

QTY. 1
1 1 1 1 1 1

Falcont Ultra B (07- 07)

49

OPTIONS
3

HOSES, SOLUTION AND VACUUM
5 7 1

4

4 2

REF 1
Y2 Y3 Y4

PART # 160185
160186
160187
150913 150933 150615

DESCRIPTION
HOSE, SOLUTION 3/8X4.6M/15' (OPTIONAL)
HOSE, SOLUTION 3/8X7.6M/25' (STANDARD)
HOSE, SOLUTION 3/8X15.2M/50' (OPTIONAL)
DFITTING, BRS, QDC, PF04, SER60
FITTING, BRS, QDC, PM04, SER60
FITTING, BRS, STR, PM04, CLOSE, T

QTY. 1
1
1
1 1 2

 ASSEMBLY Y INCLUDED IN ASSEMBLY
D RECOMMENDED STOCK ITEMS

6

REF 5
Y6 7
N/S

PART # 160400
160401
160402 160430 12694
220040

DESCRIPTION
HOSE, VACUUM 1- 1/2X4.6M/15' (OPTIONAL)
HOSE, VACUUM 1- 1/2X7.6M/25' (STANDARD)
HOSE, VACUUM 1- 1/2X15.2M/50' (OPTIONAL)
DCUFF, HOSE 1- 1/2"
DFITTING, PLSTC, STR, BM24/BM24
DBAG, HOSE W/DRAW STRING (OPTIONAL)

QTY. 1
1
1 2 1
1

PUMP- UP CARPET SPRAYER

1

REF

PART # DESCRIPTION

1 605848 DSPRAYER 2GAL PUMPUP HEAVY DUTY

D RECOMMENDED STOCK ITEMS

QTY. 1

50

Falcont Ultra B (03- 12)


Acrobat Distiller 10.0.0 (Windows)