Fujitsu Inverter Multi Air Conditioner - Wall Mounted Type
This service manual provides detailed information for Fujitsu Inverter Multi Air Conditioners, Wall Mounted type.
Models Covered
- Indoor Units: ASYA07LACM, ASYA09LACM, ASYA12LACM
- Outdoor Units: AOYA18LAT3, AOYA24LAT3
Contents
The manual covers the following sections:
- Specifications
- Outline and Dimensions
- Refrigerant System Diagram
- Circuit Diagram
- Indoor PCB Circuit Diagram
- Outdoor PCB Circuit Diagram
- Error Contents
- Parts (Indoor Unit)
- Parts (Outdoor Unit)
- Standard Accessories
Specifications - Indoor Unit
Category | Details | ASYA07LACM | ASYA09LACM | ASYA12LACM |
---|---|---|---|---|
ELECTRICAL DATA | Cooling Capacity | 2.3 kW | 2.7 kW | 3.5 kW |
Heating Capacity | 2.7 kW | 3.3 kW | 4.0 kW | |
Moisture Removal | 0.8 L/hr | 1.0 L/hr | 1.2 L/hr | |
Air Circulation High | 500 m³/hr | 550 m³/hr | 580 m³/hr | |
FAN MOTOR | Power Source | 230 V | ||
Discrimination | MFD-34ROM | |||
Fan Speed (cool / heat) | High speed: 1,140 / 1,140 r.p.m. Middle: 1,000 / 1,050 r.p.m. Low: 880 / 980 r.p.m. Quiet: 700 / 800 r.p.m. | High speed: 1,220 / 1,220 r.p.m. Middle: 1,060 / 1,110 r.p.m. Low: 900 / 1,040 r.p.m. Quiet: 720 / 830 r.p.m. | High speed: 1,280 / 1,320 r.p.m. Middle: 1,100 / 1,180 r.p.m. Low: 900 / 1,080 r.p.m. Quiet: 750 / 860 r.p.m. | |
Noise Level | High Speed: 35 dB(A) Quiet: 21 dB(A) | High Speed: 38 dB(A) Quiet: 22 dB(A) | High Speed: 39 dB(A) Quiet: 23 dB(A) | |
MEASUREMENT | Dimensions (H x W x D) | 275 x 790 x 215 mm | ||
Weight (Gross / Net) | 12 kg / 9 kg |
Specifications - Outdoor Unit
Category | Details | AOYA18LAT3 | AOYA24LAT3 |
---|---|---|---|
ELECTRICAL SPECIFICATIONS | Type | Cooling & heating multi | Cooling & heating multi |
Model Name | AOYA18LAT3 | AOYA24LAT3 | |
Cooling Capacity | 5.4 kW | 6.8 kW | |
Heating Capacity | 6.8 kW | 8.0 kW | |
Power Supply | (220V) - 230V - (240V) | (220V) - 230V - (240V) | |
Frequency | 50 Hz | 50 Hz | |
Running Current (Cooling / Heating) | 5.9 A / 7.1 A | 8.5 A / 8.8 A | |
INPUT | Cooling | 1.35 kW | 1.94 kW |
Heating | 1.62 kW | 2.00 kW | |
EER | Cooling | 4.00 kW/kW | 3.50 kW/kW |
Heating | 4.20 kW/kW | 4.00 kW/kW | |
AIR CIRCULATION HIGH | 3,050 m³/hr | 3,300 m³/hr | |
FAN MOTOR | Discrimination | MFE-60PO | MFE-60PO |
High Speed (Cool / Heat) | 730 r.p.m. / 660 r.p.m. | 780 r.p.m. / 780 r.p.m. | |
NOISE LEVEL | Cool | 48 dB(A) | 50 dB(A) |
Heat | 49 dB(A) | 51 dB(A) | |
MEASUREMENT | Dimensions (H x W x D) | 700 x 900 x 330 mm | |
Weight (Net / Gross) | 55 kg / 63 kg | ||
COMPRESSOR AND REFRIGERANT | Compressor Type | Hermetic type, Inverter, 4 poles, 3-phase, DC motor, Twin Rotary | |
Discrimination | DA150A1F-20NA | ||
Weight (with oil) | 10.0 kg | ||
Refrigerant | 2,200 g | ||
Refrigerant Type | R410A | ||
Full Charge Amount | 30 m: 2,200 g 40 m: 2,400 g 50 m: 2,600 g | ||
Additional Charge | 20 g/m | ||
PIPE SPECIFICATIONS | Chargeless | 30 m | |
Max Pipe Length (each unit) | 25 m | ||
Max Pipe Length (total) | 50 m | ||
Max Elevation (between indoor units) | 10 m | ||
Max Elevation (between indoor and outdoor) | 15 m | ||
Min. Pipe Length (each unit) | 5 m |
Dimensions - Indoor Unit
The indoor unit dimensions are:
- Width: 790 mm
- Height: 275 mm
- Depth: 215 mm
Dimensions - Outdoor Unit
The outdoor unit dimensions are:
- Width: 900 mm
- Height: 700 mm
- Depth: 400 mm
- Side Panel Depth: 330 mm
- Air flow is indicated from the front.
Refrigerant System Diagram
The refrigerant system diagram illustrates the flow of refrigerant between the outdoor unit and multiple indoor units (A, B, C). Key components include:
- Outdoor Unit: Compressor, Muffler, Accumulator, Pressure Switches (A, B), 4-way valve, Heat Exchanger, Receiver Tank, Strainer, Distributor.
- Connecting Pipes: Expansion Valves, Pipe Thermistors, Strainers, 3-way valves, 2-way valves.
- Indoor Units: Room Thermistors, Heat Exchangers.
The system allows for both cooling and heating modes, controlled by the 4-way valve and expansion valves.
Circuit Diagrams
The document contains detailed circuit diagrams for both the Indoor Unit and Outdoor Unit, illustrating the electrical connections between various components such as:
- Indoor Unit: Controller PCB Assembly (Main PCB), Fan Motor, Step Motor, Pipe Temperature Thermistor, Room Temperature Thermistor, Thermal Fuse, Varistor, Display Board, and connections to the outdoor unit.
- Outdoor Unit: DC Compressor, DC Fan Motor, IPM, Diode Bridge, 4-Way Valve, Construction Check Switch, Pressure Switches, Expansion Valves (A, B, C), various Thermistors (Heatsink, Compressor, Outdoor, Pipe, Discharge), 2-way and 3-way Valves, Power Supply PCB Assembly, Controller PCB Assembly (Main PCB), EMI Filters, Choke Coil, and terminals for AC input and output to indoor units.
- PCB Diagrams: Detailed diagrams for the Indoor Controller PCB Assembly and Outdoor Controller PCB Assembly show connections to various sensors, motors, valves, and communication interfaces.
Error Contents
The manual lists potential error codes and their corresponding symptoms and LED indications for both indoor and outdoor units.
Indoor Unit Error Contents
Errors are categorized by type (e.g., Communication error, Indoor unit temperature error, Outdoor unit temperature error, Indoor unit control system error, Outdoor unit control system error, Refrigerant system error, Added function error, Indoor unit connect error) and described by the number of flashes or states (off, blinking) of the operation, timer, air clean, and coil dry LEDs.
Outdoor Unit LED Indications
Specific LED (A, B, C) indications for outdoor unit errors are provided, detailing the number of times a LED flashes or if it is off, for errors such as communication errors, temperature sensor errors, valve errors, compressor errors, fan motor errors, IPM errors, and microcomputer errors.
Parts Lists
Detailed parts lists with descriptions and part numbers are provided for both indoor and outdoor units, including exploded views for identification.
Indoor Unit Parts
- Front Panel Assembly: Includes Front Panel Assy, Intake Grille Assy, Air Filter, Front Panel, Clamper (Grille), Air Clean Filter Assy, Electric Filter Holder, Remote Control Unit, and Remote Control Holder.
- Casing Assembly: Includes Casing Assy, Casing Cover B, Casing Cover F, Louver Holder, Drain Hose Assy, Drain Cap Assy, Louver U Assy, and Louver Z Assy.
- Main Components: Includes Gear A, Crossflow Fan Assy, Clamp (Motor), Shaft Holder C Assy, Wire Clamper, Holder (Room Thermistor), Cover (Switch), Evaporator Total Assy, Joint Pipe Assy, Insulation (Pipe) E, Holder (Evaporator) L/R, Water Seal, Terminal, Step Motor, Fan Motor Assy, and various Controller PCB Assemblies and Thermistors.
Outdoor Unit Parts
- External Components: Includes Top Panel Sub Assy, Front Panel, Fan Guard, Grip Side, Service Panel Sub Assy, Right Panel, Grip, Valve Cover Sub Assy, Propeller Fan Assy, Fan Motor, Condenser A Assy, Base Assy, Cap Foot, Protective Net, and Emblem Rear.
- Internal Components: Includes Separate Wall Assy, Coil Choke, Compressor Assy, 4-Way Valve Assy, Inlet/Outlet Pipe Assy, Pressure Switches (A, B), Accumulator Assy, Receiver Tank Assy, Valve Plate Assy, Pulse Motor Valve, 3-Way Valve Assy, 2-Way Valve Assy, Solenoids, Thermistors, Compressor Plate Assy, Water Seal Plate, Thermo Holder, Compressor Covers (A, B, C), Inverter Boxes (A, B, C, D, Duct, Cover), Fuse Holders, Fuses, Terminals, ACTPM, Power Supply PCB Assy, Controller PCB Assy, and Thermo Holders.
Standard Accessories
The following accessories are supplied with the units:
Indoor Unit Accessories
- Wall hook bracket (1 pc) - For indoor unit installation
- Remote control unit (1 pc) - For air conditioner operation
- Battery (penlight) (2 pcs) - For remote control unit
- Cloth tape (1 pc) - For indoor unit installation
- Remote control unit holder (1 pc) - For use as remote control unit holder
- Tapping screw (big) (8 pcs) - For wall hook bracket installation
- Tapping screw (small) (2 pcs) - For remote control unit holder installation
Outdoor Unit Accessories
- Drain pipe (1 pc) - For outdoor unit drain piping work
- Drain cap (2 pcs)
- Adapter assy (1 pc) - For connecting models 9-12 to outdoor port A
- Putty (1 pc) - For sealing
Document Reference
Document Number: 0703G3212