7 oct. 2022 — The 58SB0B/58SB1B Comfort™ Series 4-way Multipoise Gas Furnaces feature Carrier's QuieTech™ noise reduction system for incredibly quiet.
Carrier Comfort™ Multipoise Furnace, 80% AFUE, 70,000 BTU, 18 Speed ECM, Single Stage, 115/1
Carrier Comfort™ Multipoise Furnace, 80% AFUE, 18 Speed ECM, Single Stage, Low NOx, 115/1
58SB0B/58SB1B Comfort 80, 80% AFUE, Single-Stage, Multi 18-Speed ECM, Non-Condensing Gas Furnaces Product Data Representative drawing only. Some product models may vary. A190411 ! WARNING This furnace is not designed for use in mobile homes, trailers, or recreational vehicles. Such use could result in property damage and/or death. The 58SB0B/58SB1B ComfortTM Series 4-way Multipoise Gas Furnaces feature Carrier's QuieTechTM noise reduction system for incredibly quiet induced draft operation. Applications are easy with 4-way multipoise design, through-the-furnace downflow venting, 13 different venting options, and designed for easy service access. An inner blower door is provided for tighter sealing in sensitive applications. Improved serviceability with the 3 digit status display and NFC enabled board allowing setup via the service tech app. The 58SB0B/58SB1B furnaces are approved for use with natural or propane gas, and the 58SB1B-Low NOx units are designed for California installations and can be installed in air quality management districts with a 40 ng/J NOx emissions limit. PERFORMANCE · Single Stage gas valve · Multi 18-Speed, constant torque (MCT) ECM blower motor · QuieTechTM noise reduction system · Microprocessor based control center · Adjustable heating air temperature rise · Adjustable cooling airflow · Enhanced diagnostics with easy to read 3 digit display for faults and status · Stores fault codes during power outages · Power HeatTM Igniter · Draft safeguard switch designed to ensure proper furnace venting · Inner door for tighter sealing INSTALLATION FLEXIBILITY · 4-way Multipoise furnace, 13 vent applications · On-board NFC antenna makes setup a tap away when using the Carrier service technician app · HYBRID HEAT® Dual Fuel System compatible · All models are chimney friendly when used with accessory vent kit · Select sizes approved for twinning, refer to accessory kit listing APPLICATIONS · Compact design - only 33-1/3 in. (847 mm) tall · Propane convertible with gas conversion accessory · Convenient Air Purifier and Humidifier connections CERTIFICATION · Cabinet air leakage less than 2.0% at 1.0 in. w.c. and cabinet air leakage less than 1.4% at 0.5 in. w.c. when tested in accordance with ASHRAE standard 193 · Residential installations eligible for consumer financing through the Retail Credit Program A200123 58SB0B/58SB1B: Product Data DIMENSIONAL DATA NOTE: ALL DIMENSIONS IN INCH (MM) U.S. ECCN: Not Subject to Regulation (N.S.R.) SD5669-4 REV. - A210785 Unit Size 045M14--12 045M17--14 070M14--12 070M17--12 070M17--16 070M21--16 090M17--14 090M21--16 090M21--20 090M24--20 110M21--20 110M24--20 135M24--20 155M24--20 A CABINET WIDTH 14-3/16 (360) 17-1/2 (445) 14-3/16 (360) 17-1/2 (445) 17-1/2 (445) 21 (533) 17-1/2 (445) 21 (533) 21 (533) 24-1/2 (622) 21 (533) 24-1/2 (622) 24-1/2 (622) 24-1/2 (622) B OUTLET WIDTH 12-9/16 (319) 15-7/8 (403) 12-9/16 (319) 15-7/8 (403) 15-7/8 (403) 19-3/8 (492) 15-7/8 (403) 19-3/8 (492) 19-3/8 (492) 22-7/8 (581) 19-3/8 (492) 22-7/8 (581) 22-7/8 (581) 22-7/8 (581) Dimensions C TOP AND BOTTOM FLUE COLLAR 9-5/16 (237) 11-9/16 (294) 9-5/16 (237) 11-9/16 (294) 11-9/16 (294) 13-5/16 (338) 11-9/16 (294) 13-5/16 (338) 13-5/16 (338) 15-1/16 (383) 13-5/16 (338) 15-1/16 (383) 15-1/16 (383) 15-1/16 (383) D BOTTOM INLET WIDTH 12-11/16 (322) 16 (406) 12-11/16 (322) 16 (406) 16 (406) 19-1/2 (495) 16 (406) 19-1/2 (495) 19-1/2 (495) 23 (584) 19-1/2 (495) 23 (584) 23 (584) 23 (584) VENT CONNECTION SIZE 4 (102) 4 (102) 4 (102) 4 (102) 4 (102) 4 (102) 4 (102) 4 (102) 4 (102) 4 (102) 4 (102) 4 (102) 4 (102)* 4 (102)* SHIP WT. LB. (KG) 108 (49) 121 (55) 114 (52) 124 (56) 127 (58) 139.5 (63) 133 (60) 140.5 (64) 147 (67) 150 (68) 150 (68) 165 (75) 167 (76) 171 (77) *. 135 and 155 size furnaces requires a 5 or 6-in. (127 or 152 mm) vent. Use a vent adapter between furnace and vent stack. See Installation Instructions for complete installation requirements Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 2 58SB0B/58SB1B: Product Data MODEL NUMBER NOMENCLATURE 6 1, 2 3 4 5 Major Gas Furnace Heating Stages Tier Min. AFUE/NOx Series 59 M N 7 B | | | | | 7, 8, 9 Heating Input 060 | 10 Motor Type E | 11, 12 Width 17 | 13 Voltage (1-phase) 1 | 58 = 80% Non-Condensing 59 = 90%+ Condensing M = Modulating T = Two Stage B = Base C = Comfort E = Export 0 = 80% 1 = 80% Low NOx (Not Ultra Low NOx) C = Constant Airflow Variable- Speed (VCA) ECM S = Single Stage N = Infinity 2 = 92% V = Variable-Speed C = Single Stage P = Performance 5 = 95% 026 = 26,000 BTU (VCT) PWM Communicating U = Ultra Low 6 = 96% A 040 = 40,000 BTU M = Multi 18-Speed Nox 7 = 97% B 060 = 60,000 BTU Constant Torque 8 = 98% C --- (MCT) ECM --- 155 = 155,000 BTU 14 - 14.2" 17 - 17.5" 21 - 21.0" 24 - 24.5" 1 = 110V/60Hz 2 = 230V/50Hz FURNACE COMPONENTS CLEARANCES 14 Minor Series 1 | 1 2 3 --- 15, 16 Airflow 16 | 08 = 800 CFM 10 = 1000 CFM 12 =1200 CFM 14 = 1400 CFM 16 = 1600 CFM 20 = 2000 CFM 22 = 2200 CFM A220581 A190086 Representative drawing only, some models may vary. The furnaces are factory shipped for use with natural gas. These furnaces can be field-converted for propane gas with a factory-authorized and listed accessory conversion kit. A220231 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 3 58SB0B/58SB1B: Product Data SPECIFICATIONS UNIT SIZE 045M14--12 045M17--14 070M14--12 070M17--12 070M17--16 070M21--16 090M17--14 HEATING AND CAPACITY AND EFFICIENCY Input BTUh* All Standard Low NOx - Upflow Low NOx - Dwnflw/Hz Output Capacity (BTUh) All Standard Low NOx - Upflow Low NOx - Dwnflw/Hz Certified Temperature Rise Range - °F (°C) AFUE 44,000 42,000 36,000 34,000 30-60 (17-33) 44,000 42,000 35,000 34,000 30-60 (17-33) 66,000 63,000 54,000 51,000 30-60 (17-33) 66,000 63,000 54,000 51,000 30-60 (17-33) 80% 66,000 63,000 54,000 51,000 25-55 (14-31) 66,000 63,000 53,000 51,000 25-55 (14-31) 88,000 84,000 71,000 68,000 40-70 (22-39) AIRFLOW CAPACITY AND BLOWER DATA Rated Certified External Static Pressure Heating Cooling Airflow CFM @ Rated ESP (CFM) Heating Cooling 0.10 0.50 715 175-1095 0.10 0.50 720 210-1285 0.12 0.50 1075 180-1115 0.12 0.50 1110 155-1160 0.12 0.50 1310 235-1700 0.12 0.50 1290 210-1820 0.15 0.50 1230 330-1490 Direct Drive Motor HP 1/3 1/2 1/3 1/3 3/4 3/4 1/2 Motor Full Load Amps 4.4 6.7 4.4 4.4 8.8 8.8 6.7 Heating Blower Control (Htg OFF-Delay) Adjustable: 90, 120 (factory-set), 150, 180 seconds Cooling Blower Control (Clg OFF-Delay) Blower Wheel Diameter x Width - In. (mm) Air Filtration System Filter used for Certified Watt Data 10x6 (254x152) Adjustable: 90 (factory-set), 5, 30 seconds 10x8 10x6 10x8 11x8 10x10 (254x203) (254x152) (254x203) (279x203) (254x254) Field Supplied Filter 325531-40** 10x8 (254x203) ELECTRICAL DATA Unit Volts-Hertz-Phase Operating Voltage Range Min-Max 115-60-1 104-127 Maximum Unit Amps 6.0 7.9 6.0 5.9 10.4 10.4 8.2 Unit Ampacity 8.3 10.7 8.3 8.2 13.8 13.8 11.0 Maximum Wire Length (Measure 1 way in Ft/M) Minimum Wire Size AWG Max. Fuse/Ckt Bkr Size (Time-Delay Type Recommended) Amps Transformer Capacity (24 VAC output) External Control Power Available Heating Cooling 44/13.6 14 15 34/10.6 14 15 44/13.6 14 15 45/13.80 14 15 40VA 12VA 35VA 26/8.2 14 15 26/8.2 14 15 34/10.3 14 15 GAS CONTROLS Burners 2 2 3 3 3 3 4 Gas Connection Size Gas Valve (Redundant) Min. inlet pressure Max. inlet pressure Mfr (in.w.c.) (in.w.c.) 1/2 in. NPT WhiteRodgersTM 4.5 (Natural Gas) 13.6 (Natural Gas) Ignition Device Silicon Nitride Factory installed orifice Size 43 CONNECTIONS Communication System None Thermostat Connections G, C, W, Y, R Accessory Connections EAC-1 (115 VAC); HUM (24 VAC); 1-STG AC (via Y) *. Gas input ratings are certified for elevations to 2000 ft. (610 M). In USA, For elevations above 2000 ft (610 M), reduce ratings 4 percent for each 1000 ft (305 M) above sea level. Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1 Table F.4 or furnace installation instructions. . Capacity in accordance with U.S. Government DOE test procedures. . Airflow shown is for bottom only return-air supply for the as-shipped speed tap. For air delivery above 1800 CFM, see Air Delivery table for other options. A filter is required for each return-air supply. An airflow reduction of up to 7 percent may occur when using the factory-specified 4-5/16-in. (110 mm) wide, high efficiency media filter. **. See Accessory List for part numbers available. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 4 58SB0B/58SB1B: Product Data UNIT SIZE 090M21--16 090M21--20 090M24--20 110M21--20 110M24--20 135M24--20 155M24--20 HEATING AND CAPACITY AND EFFICIENCY Input BTUh* All Standard Low NOx - Upflow Low NOx - Dwnflw/Hz Output Capacity (BTUh) All Standard Low NOx - Upflow Low NOx - Dwnflw/Hz Certified Temperature Rise Range - °F (°C) AFUE 88,000 84,000 72,000 68,000 35-65 (19-36) 88,000 84,000 71,000 68,000 25-55 (14-31) 88,000 - 72,000 30-60 (17-33) 110,000 105,000 90,000 85,000 30-60 (17-33) 80% 110,000 105,000 90,000 85,000 30-60 (17-33) 132,000 126,000 107,000 102,000 40-70 (22-39) 154,000 147,000 125,000 119,000 45-75 (25-42) AIRFLOW CAPACITY AND BLOWER DATA Rated Certified External Static Pressure Heating Cooling Airflow CFM @ Rated ESP (CFM) Heating Cooling 0.15 0.50 1325 315-1565 0.15 0.50 1645 325-2315 0.15 0.50 1515 265-1980 0.20 0.50 1840 420-2350 0.20 0.50 1970 400-2005 0.20 0.50 1805 290-1925 0.20 0.50 1945 290-1985 Direct Drive Motor HP 1/2 1 3/4 1 3/4 3/4 3/4 Motor Full Load Amps 6.7 11.5 8.8 11.5 8.8 8.8 8.8 Heating Blower Control (Htg OFF-Delay) Adjustable: 90, 120 (factory-set), 150, 180 seconds Cooling Blower Control (Clg OFF-Delay) Blower Wheel Diameter x Width - In. (mm) Air Filtration System Filter used for Certified Watt Data 10x10 (254x254) Adjustable: 90 (factory-set), 5, 30 seconds 11x11 11x11 11x11 11x11 11x11 (279x279) (279x279) (279x279) (279x279) (279x279) Field Supplied Filter 325531-40** 11x11 (279x279) ELECTRICAL DATA Unit Volts-Hertz-Phase Operating Voltage Range Min-Max 115-60-1 104-127 Maximum Unit Amps 8.2 13.9 10.7 14.4 11.1 11.0 10.7 Unit Ampacity 11.0 18.1 14.1 18.6 14.6 14.4 14.1 Maximum Wire Length (Measure 1 way in Ft/M) Minimum Wire Size AWG Max. Fuse/Ckt Bkr Size (Time-Delay Type Recommended) Amps Transformer Capacity (24 VAC output) External Control Power Available Heating Cooling 34/10.3 14 15 31/9.6 12 20 26/8.0 14 15 30/9.4 12 20 40VA 12VA 35VA 25/7.7 14 15 25/7.8 14 15 26/8.0 14 15 GAS CONTROLS Burners 4 4 4 5 5 6 6 Gas Connection Size Gas Valve (Redundant) Min. inlet pressure Max. inlet pressure Mfr (in.w.c.) (in.w.c.) 1/2 in. NPT WhiteRodgersTM 4.5 (Natural Gas) 13.6 (Natural Gas) Ignition Device Silicon Nitride Factory installed orifice Size 43 CONNECTIONS Communication System None Thermostat Connections G, C, W, Y, R Accessory Connections EAC-1 (115 VAC); HUM (24 VAC); 1-STG AC (via Y) *. Gas input ratings are certified for elevations to 2000 ft. (610 M). In USA, For elevations above 2000 ft (610 M), reduce ratings 4 percent for each 1000 ft (305 M) above sea level. Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1 Table F.4 or furnace installation instructions. . Capacity in accordance with U.S. Government DOE test procedures. . Airflow shown is for bottom only return-air supply for the as-shipped speed tap. For air delivery above 1800 CFM, see Air Delivery table for other options. A filter is required for each return-air supply. An airflow reduction of up to 7 percent may occur when using the factory-specified 4-5/16-in. (110 mm) wide, high efficiency media filter. **. See Accessory List for part numbers available. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 5 58SB0B/58SB1B: Product Data AIR DELIVERY (with filter) Unit Size 045M14--12 045M17--14 070M14--12 Airflow Setting 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Air Delivery - CFM (with filter)* Default Setting Constant Fan Heating Cooling Constant Fan Heating Cooling Constant Fan Heating Cooling External Static Pressure (in. w.c.) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 455 385 320 250 175 -- -- -- -- -- 490 425 360 300 225 150 -- -- -- -- 535 480 415 360 305 230 160 -- -- -- 565 510 450 395 345 285 215 135 -- -- 605 555 500 445 390 345 285 215 145 -- 645 595 545 490 440 395 350 290 225 155 695 645 600 550 500 455 410 370 310 255 715 670 625 575 530 485 440 400 355 290 770 730 685 640 595 555 510 470 430 390 825 780 740 700 660 615 575 535 500 460 870 830 795 755 720 680 640 600 560 525 920 880 845 810 775 735 700 660 625 590 965 930 895 855 825 790 755 720 685 650 1005 970 935 905 875 840 805 770 740 705 1055 1020 990 960 930 895 865 835 800 770 1105 1070 1040 1010 980 950 925 895 860 830 1125 1095 1065 1035 1005 975 950 920 890 860 1210 1180 1150 1120 1095 1065 1040 1010 980 945 495 425 345 270 210 135 -- -- -- -- 540 475 400 330 270 205 135 -- -- -- 580 520 455 380 320 260 200 160 -- -- 635 575 520 450 385 330 275 215 155 -- 685 630 570 515 450 390 340 290 235 180 720 665 615 560 505 445 395 345 295 245 770 720 665 615 565 505 450 400 355 310 830 785 735 690 640 590 535 485 440 395 880 840 790 745 705 660 610 555 510 465 945 905 860 815 775 735 690 645 595 550 1005 965 920 880 840 800 760 725 680 630 1060 1025 985 940 905 865 825 790 750 710 1120 1085 1050 1010 970 935 900 865 830 795 1170 1135 1100 1065 1030 995 960 925 890 855 1235 1205 1170 1135 1100 1065 1035 1000 965 915 1295 1265 1235 1200 1170 1135 1105 1075 1020 930 1365 1335 1305 1270 1240 1210 1180 1125 1035 930 1460 1420 1375 1330 1285 1235 1190 1130 1035 930 465 400 330 250 180 115 -- -- -- -- 500 440 370 295 225 165 115 - -- -- 550 490 430 365 300 235 175 130 --- -- 595 540 485 425 355 295 240 185 135 -- 635 580 530 475 420 355 300 245 195 145 675 625 575 525 470 410 355 300 250 205 715 670 625 575 525 475 420 370 320 270 760 720 675 630 585 535 490 435 390 340 805 765 725 685 640 595 550 505 455 410 855 820 780 740 700 660 615 575 530 485 905 870 835 795 760 720 685 645 600 560 950 915 880 845 810 775 740 700 665 625 1005 970 940 905 870 840 805 770 735 700 1055 1020 990 960 930 895 865 830 800 765 1085 1055 1025 995 965 935 900 870 840 810 1120 1090 1060 1030 1000 970 940 910 880 850 1150 1120 1095 1065 1035 1005 975 945 920 890 1220 1195 1170 1140 1115 1090 1060 1035 1005 970 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 6 58SB0B/58SB1B: Product Data Unit Size 070M17--12 070M17--16 070M21--16 Airflow Setting 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Air Delivery - CFM (with filter)* (Continued) Default Setting Constant Fan Heating Cooling Constant Fan Heating Cooling Constant Fan Heating Cooling 0.1 475 515 565 610 655 700 740 790 835 880 935 985 1035 1080 1120 1175 1225 1300 545 605 665 740 810 870 955 1025 1095 1175 1220 1320 1390 1475 1550 1630 1705 1840 590 665 730 820 875 950 1045 1140 1200 1300 1370 1455 1535 1615 1705 1775 1870 2025 0.2 385 430 490 540 590 635 685 735 785 830 890 940 990 1040 1075 1140 1190 1265 465 535 595 675 750 815 900 975 1050 1135 1180 1285 1355 1435 1520 1600 1675 1810 495 580 655 750 810 885 985 1085 1145 1250 1320 1410 1490 1575 1670 1745 1840 1975 External Static Pressure (in. w.c.) 0.3 0.4 0.5 0.6 0.7 0.8 300 220 155 - -- -- 350 275 200 130 -- -- 410 340 270 205 140 -- 470 400 335 265 210 150 525 455 395 330 270 215 570 505 445 385 325 270 620 560 500 445 390 335 675 620 565 510 455 400 730 675 620 570 515 465 780 725 675 625 575 525 840 790 740 690 645 595 895 845 800 750 705 665 950 900 855 810 770 730 995 950 910 865 825 785 1035 995 950 910 870 830 1100 1060 1020 980 940 905 1155 1115 1080 1040 1000 965 1230 1190 1160 1120 1085 1050 385 310 235 155 -- -- 455 385 315 250 175 - 530 460 395 330 270 205 615 550 490 430 370 315 690 635 570 515 460 405 760 705 650 595 545 490 850 795 745 695 645 595 925 880 835 785 735 685 1005 955 915 870 820 770 1090 1045 1005 960 920 875 1135 1095 1055 1015 975 935 1245 1205 1170 1130 1095 1055 1315 1280 1245 1210 1170 1135 1405 1370 1335 1300 1265 1235 1485 1450 1415 1385 1350 1320 1570 1540 1510 1480 1450 1420 1640 1615 1590 1560 1535 1505 1775 1735 1700 1660 1620 1580 390 290 210 120 -- -- 485 390 300 225 145 - 565 480 385 310 245 170 675 595 520 435 360 300 740 665 595 515 435 370 830 760 695 625 550 480 930 875 810 750 685 620 1030 980 925 865 810 750 1095 1050 1000 945 885 835 1195 1155 1110 1065 1015 960 1275 1230 1190 1150 1105 1055 1365 1325 1285 1245 1205 1165 1450 1415 1375 1340 1305 1265 1535 1495 1460 1425 1390 1355 1635 1600 1565 1535 1505 1470 1710 1680 1650 1620 1590 1560 1810 1780 1750 1725 1705 1670 1925 1875 1820 1770 1725 1680 0.9 ----155 220 280 350 415 480 550 620 685 745 790 865 930 1015 ---255 355 440 545 645 730 830 890 1015 1100 1200 1290 1390 1480 1540 ---235 315 410 555 695 780 910 1005 1115 1225 1320 1435 1530 1630 1630 1 -----165 235 300 365 430 505 575 640 705 750 830 895 980 ---190 305 390 495 595 685 790 850 980 1065 1165 1260 1365 1455 1500 ---165 250 360 490 635 730 865 960 1070 1185 1285 1400 1505 1530 1535 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 7 58SB0B/58SB1B: Product Data Unit Size 090M17--14 090M21--16 090M21--20 Airflow Setting 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Air Delivery - CFM (with filter)* (Continued) Default Setting Constant Fan Heating Cooling Constant Fan Heating Cooling Constant Fan Heating Cooling 0.1 670 705 760 810 860 910 950 1025 1075 1140 1210 1255 1280 1340 1410 1475 1550 1620 685 745 810 860 915 980 1040 1100 1170 1225 1295 1315 1350 1420 1495 1565 1645 1725 770 850 925 1030 1120 1210 1285 1385 1480 1570 1675 1775 1865 1965 2075 2170 2270 2485 0.2 595 635 695 750 800 855 900 975 1030 1095 1165 1210 1235 1300 1370 1440 1515 1585 585 660 725 785 845 910 980 1040 1110 1170 1245 1265 1300 1375 1455 1525 1605 1680 655 745 825 940 1040 1130 1215 1320 1415 1510 1615 1720 1815 1920 2030 2135 2225 2445 External Static Pressure (in. w.c.) 0.3 0.4 0.5 0.6 0.7 0.8 485 405 330 245 190 130 535 450 380 305 235 180 625 520 450 380 310 245 685 585 515 450 385 320 745 675 580 510 450 390 800 740 650 580 515 460 850 790 730 640 575 515 925 875 820 740 670 615 985 935 885 835 745 690 1050 1005 960 910 855 775 1125 1085 1040 995 950 895 1170 1130 1085 1045 1000 955 1200 1160 1115 1075 1030 990 1265 1225 1185 1145 1105 1065 1335 1300 1265 1225 1190 1150 1405 1370 1335 1300 1265 1225 1480 1445 1415 1380 1345 1310 1555 1520 1490 1460 1425 1375 490 395 315 240 170 -- 560 480 390 320 250 185 635 550 475 395 325 265 700 615 540 465 395 335 765 680 610 535 465 400 840 765 690 620 555 490 910 840 770 700 635 575 975 910 840 770 710 650 1055 995 930 870 800 745 1110 1055 995 930 865 810 1195 1135 1085 1025 970 905 1215 1160 1110 1055 1000 935 1250 1195 1145 1090 1035 975 1330 1280 1230 1185 1130 1075 1405 1360 1315 1270 1220 1170 1480 1435 1395 1350 1305 1260 1565 1525 1480 1435 1390 1345 1645 1605 1565 1520 1480 1420 540 430 325 195 -- -- 640 535 435 340 210 - 725 625 530 435 345 230 845 755 665 575 490 405 950 865 780 700 615 540 1050 970 895 810 735 655 1140 1065 990 915 840 765 1250 1180 1110 1040 975 900 1355 1290 1215 1155 1090 1025 1450 1390 1325 1260 1200 1140 1560 1505 1450 1390 1330 1270 1670 1615 1560 1510 1450 1395 1765 1715 1660 1610 1555 1500 1875 1825 1780 1730 1680 1630 1985 1940 1895 1845 1805 1760 2090 2050 2005 1965 1925 1880 2190 2150 2115 2075 2035 2000 2410 2365 2315 2265 2215 2160 0.9 -125 195 260 325 400 465 560 630 715 815 880 925 1025 1110 1190 1270 1315 --200 275 345 425 510 590 685 755 850 880 915 1020 1120 1210 1300 1340 ---315 455 580 690 835 960 1080 1210 1340 1450 1580 1710 1835 1960 2105 1 --145 210 270 345 410 510 580 665 760 820 855 965 1070 1150 1235 1255 ---215 285 370 450 530 630 700 795 830 865 960 1060 1160 1250 1260 ---185 380 510 620 765 895 1015 1155 1285 1395 1535 1660 1790 1920 2050 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 8 58SB0B/58SB1B: Product Data Unit Size 090M24--20 110M21--20 110M24--20 Airflow Setting 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Air Delivery - CFM (with filter)* (Continued) Default Setting Constant Fan Heating Cooling Constant Fan Heating Cooling Constant Fan Heating Cooling 0.1 735 830 890 975 1050 1120 1210 1295 1395 1460 1550 1615 1710 1785 1890 1970 2050 2170 845 920 1025 1115 1235 1340 1440 1530 1640 1745 1835 1895 1950 2055 2160 2260 2355 2520 840 930 1015 1095 1185 1250 1335 1435 1510 1600 1685 1760 1855 1945 2025 2055 2125 2220 0.2 610 720 790 880 960 1035 1130 1220 1320 1390 1485 1550 1650 1730 1835 1920 2000 2120 730 810 920 1015 1150 1260 1365 1460 1575 1685 1780 1840 1895 2005 2110 2210 2310 2480 725 825 915 995 1090 1160 1255 1355 1435 1530 1615 1695 1795 1885 1970 2000 2070 2170 External Static Pressure (in. w.c.) 0.3 0.4 0.5 0.6 0.7 0.8 485 375 265 135 -- -- 610 495 395 295 175 -- 680 570 470 380 280 160 775 675 575 485 405 310 865 770 680 585 500 425 950 860 770 685 595 515 1050 965 880 800 715 635 1140 1065 985 905 830 755 1250 1180 1100 1030 955 885 1325 1255 1190 1115 1045 975 1420 1355 1295 1225 1155 1090 1490 1430 1370 1305 1240 1175 1595 1535 1475 1420 1355 1295 1675 1615 1560 1510 1450 1390 1780 1725 1675 1620 1570 1520 1865 1815 1765 1715 1670 1620 1950 1905 1855 1810 1760 1720 2070 2025 1980 1930 1880 1820 625 520 420 330 240 135 705 610 515 425 345 260 825 735 645 560 475 400 930 840 760 675 595 520 1060 980 900 825 750 675 1180 1100 1025 955 885 810 1290 1215 1140 1070 1005 940 1390 1320 1250 1185 1115 1055 1510 1440 1375 1310 1250 1190 1620 1555 1495 1430 1370 1315 1720 1665 1605 1550 1490 1435 1785 1730 1675 1615 1560 1505 1840 1785 1725 1670 1615 1565 1955 1900 1845 1790 1740 1690 2065 2015 1960 1910 1860 1815 2165 2120 2070 2020 1975 1930 2265 2225 2180 2135 2090 2045 2435 2395 2350 2310 2255 2195 615 505 400 310 215 135 720 620 520 420 335 250 815 725 630 530 440 360 905 815 725 635 540 460 1005 915 835 750 665 580 1080 1000 915 840 755 675 1175 1100 1020 940 870 790 1280 1210 1140 1060 990 920 1360 1290 1225 1155 1085 1015 1455 1390 1325 1260 1190 1125 1545 1480 1420 1360 1295 1230 1630 1565 1505 1450 1390 1330 1730 1670 1610 1560 1505 1445 1830 1770 1710 1655 1605 1555 1915 1855 1800 1750 1700 1650 1945 1890 1835 1785 1735 1685 2015 1965 1910 1860 1815 1765 2115 2060 2005 1960 1905 1860 0.9 ---195 340 445 565 670 810 905 1020 1110 1235 1330 1460 1570 1675 1765 -155 320 445 600 740 875 995 1130 1260 1380 1455 1510 1640 1765 1885 2005 2135 -165 280 385 500 595 710 845 950 1060 1165 1270 1385 1495 1600 1635 1720 1810 1 ----235 360 495 605 735 840 960 1045 1175 1275 1410 1520 1625 1695 --245 380 525 675 805 930 1075 1205 1330 1400 1460 1590 1720 1840 1960 2080 --205 310 430 525 635 780 880 995 1110 1210 1330 1445 1550 1585 1670 1750 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 9 58SB0B/58SB1B: Product Data Air Delivery - CFM (with filter)* (Continued) Unit Size 135M24--20 155M24--20 Airflow Setting 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Default Setting Constant Fan Heating Cooling Constant Fan Heating Cooling 0.1 760 815 905 975 1025 1120 1205 1285 1380 1450 1555 1635 1710 1785 1870 1940 2020 2125 765 860 915 1000 1075 1170 1260 1340 1415 1505 1575 1660 1735 1825 1920 2000 2085 2205 0.2 635 700 795 870 920 1025 1120 1200 1305 1380 1480 1565 1645 1725 1805 1885 1965 2075 645 750 810 895 975 1075 1170 1255 1340 1430 1500 1590 1670 1760 1860 1945 2035 2150 External Static Pressure (in. w.c.) 0.3 0.4 0.5 0.6 0.7 0.8 520 405 290 175 -- -- 590 485 370 270 155 -- 685 590 490 380 290 185 770 680 590 490 395 310 825 740 655 560 460 375 935 845 770 690 600 505 1030 945 870 800 720 635 1120 1040 965 900 830 750 1225 1150 1075 1010 950 885 1305 1230 1160 1095 1030 975 1415 1345 1275 1210 1150 1095 1500 1435 1370 1310 1245 1190 1585 1525 1460 1400 1340 1285 1665 1600 1545 1485 1425 1375 1750 1695 1640 1580 1525 1475 1830 1780 1725 1675 1620 1570 1915 1865 1815 1765 1715 1665 2025 1975 1925 1875 1825 1775 520 395 290 185 -- -- 635 520 410 315 220 145 705 600 485 385 300 210 795 695 595 490 400 320 880 790 695 595 500 420 985 900 815 730 635 545 1090 1010 930 845 765 675 1180 1100 1025 950 870 795 1260 1190 1120 1045 970 895 1355 1290 1220 1150 1080 1010 1430 1365 1295 1230 1165 1100 1520 1455 1395 1335 1275 1210 1605 1545 1485 1425 1365 1310 1700 1640 1585 1530 1475 1425 1800 1740 1685 1630 1580 1530 1890 1825 1775 1725 1675 1625 1980 1925 1870 1825 1780 1740 2095 2040 1985 1935 1885 1835 0.9 ---205 290 420 550 675 815 910 1045 1140 1230 1320 1420 1520 1620 1705 --135 230 335 470 590 710 815 945 1030 1140 1250 1365 1475 1575 1695 1775 1 ----195 350 470 590 735 840 985 1090 1185 1275 1375 1475 1580 1640 ---145 260 390 510 625 745 870 970 1085 1185 1310 1420 1525 1650 1720 NOTE: 1. A filter is required for each return-air inlet. Airflow performance included 3/4-in. (19 mm) washable filter media such as contained in a factory - authorized accessory filter rack. See accessory list. To determine airflow performance without this filter, assume an additional 0.1 in. w.c. available external static pressure. 2. Adjust the blower airflow setting as necessary for the proper air temperature rise for each installation. 3. Airflows over 1800 CFM require bottom return, two-side return, or bottom and side return. A minimum filter size of 20" x 25" (508 x 635 mm) is required. 4. For upflow applications, air entering from one side into both the side of the furnace and a return air base counts as a side and bottom return. 5. The -- entry indicates unstable operating conditions. Airflow Settings Default Airflow Settings* Designated Airflow Settings Unit Size Heating Cooling Heating Constant Fan 045M14--12 8 18 (4-12) (1-7) 045M17--14 6 18 (4-12) (1-7) 070M14--12 15 18 (9-16) (1-7) 070M17--12 15 18 (11-17) (1-8) 070M17--16 12 18 (7-13) (1-4) 070M21--16 10 18 (6-14) (1-8) 090M17--14 12 18 (7-16) (1-9) 090M21--16 13 18 (8-16) (1-6) 090M21--20 11 17 (7-14) (1-9) 090M24--20 11 18 (7-16) (1-10) 110M21--20 12 16 (8-15) (1-9) 110M24--20 15 18 (9-17) (1-6) 135M24--20 15 18 (12-16) (1-7) 155M24--20 16 18 (13-17) (1-2) *. Setting #1 is the default setting for Constant Fan Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 10 58SB0B/58SB1B: Product Data TYPICAL WIRING SCHEMATIC FURNACE CONTROL BOARD VENTING CONFIGURATIONS A190079 A210192 Downflow Application-Vent Elbow Up then Left A03210 Downflow Application-Vent Elbow Up A03211 Upflow Application-Vent Elbow Right A03209 Downflow Application-Vent Elbow Left then Up A03207 Horizontal Right Application-Vent Elbow Left A02068 Horizontal Left Application-Vent Elbow Left A03213 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 11 58SB0B/58SB1B: Product Data Upflow Application-Vent Elbow Up A03208 A03219 Horizontal Right Application-Vent Elbow Left then Up Downflow Application-Vent Elbow Up then Right Horizontal Right Application-Vent Elbow Right A03212 A03218 A03214 Horizontal Left Application-Vent Elbow Right then Up Venting notes: 1. For common vent, vent connector sizing and vent material: United States, latest edition of the National Fuel Gas Code (NFGC), ANSI Z223.1/NFPA 54. 2. Immediately increase to 5-in. (127 mm) vent connector outside furnace casing when 5-in. (127 mm) vent connector required, refer to Note 1. 3. Side outlet vent for upflow and downflow installations must use Type B vent immediately after exiting the furnace, except when Downflow Vent Guard is used in downflow position. 4. Type B vent where required, refer to Note 1. 5. 4-in. (102 mm) single wall vent must be used inside furnace casing and the Downflow Vent Guard Kit. 6. Accessory Downflow Vent Guard Kit required in downflow installations with bottom vent configuration. 7. Chimney Adapter Kit required for exterior masonry chimney applications. Refer to Chimney Adapter Kits for sizing and complete application details. 8. Secure vent connector to furnace elbow with (2) corrosion-resistant sheet metal screws, space approximately 180 apart. 9. Secure all other single wall vent connector joints with (3) corrosion-resistant screws spaced approximately 120 apart. Secure Type B vent connectors per vent connector manufacturer's recommendations. Horizontal Left Application-Vent Elbow Right A03216 Horizontal Left Application-Vent Elbow Up A03215 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 12 58SB0B/58SB1B: Product Data ACCESSORIES PART NO. DESCRIPTION 045M14--12 045M17--14 070M14--12 070M17--12 070M17--16 070M21--16 090M17--14 ACG1425NCB* External Filter Rack, 14-1/2 x 25" X - X - - - - ACG1625NCF* External Filter Rack, 16 x 25" - X - X X - X ACG2025NCJ* External Filter Rack, 20 x 25" - - - - - X - 325531-402* Washable filter, 3/4" x 16" x 25" X X X X X - X 325531-403* Washable filter, 3/4" x 21" x 25" - - - - - X - KGADA0101ALL Coil Adapter Kits - No Offset X X X X X X X KGADA0201ALL Coil Adapter Kits - Single Offset X X X X X X X KGADA0301ALL Coil Adapter Kits - Double Offset X X X X X X X KGARP0301B14 Return Air Base (Upflow Applications) 14-3/16" wide X - X - - - - KGARP0301B17 Return Air Base (Upflow Applications) 17-1/2" wide - X - X X - X KGARP0301B21 Return Air Base (Upflow Applications) 21" wide - - - - - X - KGACA02014FC Chimney Adapter Kit, up to or equal to 110K BTUh X X X X X X X KGAFE0112UPH Flue Extension X X X X X X X KGAVE0101DNH Vent Extension Kit X X X X X X X Combustible Floor Base (Not KGASB0201ALL required when evaporator coil case X X X X X X X is used for downflow) KGBVG0101DFG Downflow Vent Guard (Not required X X X X X X X when vent is routed through cabinet) AGAGC8NPS01B* Natural-to-Propane Conversion Kit X X X X X X X AGAGC8PNS01B* Propane-to-Natural Conversion Kit X X X X X X X AGATWNDTE01B Twinning Kit FCT-ECM Motor - - - - - X - *. Purchased through Replacement Components . Factory-authorized and field installed. Fuel conversion kits are CSA recognized. X = Accessory Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 13 58SB0B/58SB1B: Product Data ACCESSORIES (Continued) PART NO. ACG2025NCJ* ACG2424NCL* 325531-403* 325531-404* KGADA0101ALL KGADA0201ALL KGADA0301ALL KGARP0301B21 KGARP0301B24 KGACA02014FC KGACA02015FC KGAFE0112UPH KGAVE0101DNH KGASB0201ALL KGBVG0101DFG AGAGC8NPS01B* AGAGC8PNS01B* AGATWNDTE01B DESCRIPTION External Filter Rack 20 x 25" External Filter Rack 24-1/2 x 24" Washable filter 3/4" x 21" x 25" Washable filter 3/4" x 24" x 25"* Coil Adapter Kits - No Offset Coil Adapter Kits - Single Offset Coil Adapter Kits - Double Offset Return Air Base (Upflow Applications) 21" wide Return Air Base (Upflow Applications) 24-1/2 wide Chimney Adapter Kit, up to or equal to 110K BTUh Chimney Adapter Kit, greater than or equal to 135K BTUh Flue Extension Vent Extension Kit Combustible Floor Base (Not required when evaporator coil case is used for down- flow) Downflow Vent Guard (Not required when vent is routed through cabinet) Natural-to-Propane Conversion Kit Propane-to-Natural Conversion Kit Twinning Kit FCT-ECM Motor 090M21--16 X X X X X X X X X X X X X X 090M21--20 X X X X X X X X X X X X X X 090M24--20 X X X X X X X X X X X X X X 110M21--20 X X X X X X X X X X X X X X 110M24--20 X X X X X X X X X X X X X X 135M24--20 X X X X X X - X X X X X X X X 155M24--20 X X X X X X - X X X X X X X X *. Purchased through Replacement Components . Factory-authorized and field installed. Fuel conversion kits are CSA recognized. X = Accessory Gas Orifice Kit - #42 (Nat Gas) Gas Orifice Kit - #43 (Nat Gas) Gas Orifice Kit - #44 (Nat Gas) Gas Orifice Kit - #45 (Nat Gas) Gas Orifice Kit - #46 (Nat Gas) Gas Orifice Kit - #47 (Nat Gas) Gas Orifice Kit - #48 (Nat Gas) Gas Orifice Kit - #54 (LP) Gas Orifice Kit - #55 (LP) Gas Orifice Kit - #56 (LP) Gas Orifice Kit - 1.25mm (LP) Gas Orifice Kit - 1.30mm (LP) ORFICIES LH32DB207 LH32DB202 LH32DB200 LH32DB205 LH32DB208 LH32DB078 LH32DB076 LH32DB203 LH32DB201 LH32DB206 LH32DB209 LH32DB210 See Installation Instructions for model, altitude, and heat value usages. DESCRIPTION HUMIDIFIER HEAT RECOVERY VENTILATOR ENERGY RECOVERY VENTILATOR UV LIGHTS ACCESSORY Model HUM Model HRV Model ERV Model UVL Carrier has a wide variety of thermostats for your system, please visit www.Carrier.com to see all thermostat and IAQ products. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 14 58SB0B/58SB1B: Product Data ACCESSORIES (Continued) DESCRIPTION Carrier Carbon Monoxide Alarm (10 pack) Carrier Infinity Air Purifier - 16x25 (407x635 mm) Carrier Infinity Air Purifier - 20x25 (508x635 mm) Carrier Infinity Air Purifier Repl. Filter- 16x25 (407x635 mm) Carrier Infinity Air Purifier Repl. Filter- 20x25 (508x635 mm) Cartridge Media Filter - 16" (407 mm) (MERV 11) Cartridge Media Filter - 16" (407 mm) (MERV 8) Cartridge Media Filter - 20" (508 mm) (MERV 8) Cartridge Media Filter - 20" (508 mm) (MERV11) Cartridge Media Filter - 24" (610 mm) (MERV 8) Cartridge Media Filter - 24" (610 mm) (MERV11) EZ Flex Cabinet Side or Bottom - 16" EZ Flex Cabinet Side or Bottom - 20" EZ Flex Replacement Filters 16" MERV 10 EZ Flex Replacement Filters 16" MERV 13 EZ Flex Replacement Filters 20" MERV 10 EZ Flex Replacement Filters 20" MERV 13 EZ Flex Replacement Filters 24" MERV 10 EZ Flex Replacement Filters 24" MERV 13 EZ-Flex Filter with End Caps - 16" (407 mm) (MERV 10) EZ-Flex Filter with End Caps - 16" (407 mm) (MERV 13) EZ-Flex Filter with End Caps - 20" (508 mm) (MERV 10) EZ-Flex Filter with End Caps - 20" (508 mm) (MERV 13) EZ-Flex Filter with End Caps - 24" (610 mm) (MERV 10) EZ-Flex Filter with End Caps - 24" (610 mm) (MERV 13) Media Filter Cabinet - 20" Media Filter Cabinet - 24" Media Filter Cabinet -16" ACCESSORY COALMCCNRB02-A10 DGAPAXX1625 DGAPAXX2025 GAPCCCAR1625-A05 GAPCCCAR2025-A05 FILXXCAR0116 FILXXCAR0016 FILXXCAR0020 FILXXCAR0120 FILXXCAR0024 FILXXCAR0124 EZXCAB--0016 EZXCAB--0020 EXPXXFIL0016 EXPXXFIL0316 EXPXXFIL0020 EXPXXFIL0320 EXPXXFIL0024 EXPXXFIL0324 EXPXXUNV0016 EXPXXUNV0316 EXPXXUNV0020 EXPXXUNV0320 EXPXXUNV0024 EXPXXUNV0324 FILCABXL0020 FILCABXL0024 FILCABXL0016 14" 17" 21" 24" X X X X X X - - - - X X X X - - - - X X X X - - X X - - - - X - - - X - - - - X - - - X X X - - - - X X X X - - X X - - - - X - - - X - - - - X - - - X X X - - X X - - - - X - - - X - - - - X - - - X - - X - - - - X X X - - © 2022 Carrier. All rights reserved. Edition Date: 08/22 Catalog No: 58SB0B-01PD REV A Replaces:58SB0B-01PD Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 15Adobe PDF Library 15.0