Professional Prestige ProTerra™ Hybrid Electric with ...

Plus… • Premium grade anode rod with resistor extends the life of the tank. • 3/4" NPT water inlet and outlet;. 3/4" condensate drain connections.

Product Specifications

Rheem's Hybrid Electric Water Heater Is the Most Efficient Rheem Water Heater Available - Rheem Water Heaters

PDF preview unavailable. Download the PDF instead.

HP-350-5CAN-Rev2-092420
Water

Residential Electric Professional Prestige ProTerra Hybrid Water Heaters

Professional Prestige® ProTerraTM Hybrid Electric with LeakGuardTM is the most efficient water heater available

Efficiency
· Up to 4.0 UEF reduces operating cost · ENERGY STAR® rated
Performance
· Delivers hot water faster than most standard electric water heaters
· Ambient operating range: 37-145° F is widest in class, offering more days of HP operation annually; designed to meet Northern Climate Spec (Tier 4)
Easy Installation
· Easy access side connections
· Quick access to electrical junction box
· Easily replaces a standard electric water heater
Integration
· LED Screen with built-in water sensor alert with audible alarm1
· Integrated EcoNet® WiFi-c onnected2 technology and free mobile app gives users control over water heater, allowing for customizable temperature, vacation settings, energy savings and system monitoring at home or away. Visit Rheem.com/hybridsolutions
· Integrated leak detection and prevention system with factory installed auto water shut-off valve limits leaks to no more than 20 ounces of water1, 3
· LeakSenseTM Built-in Leak Detection System detects any leak large or small, internal or external1, 4

Operation Modes
· Energy Saver
· Heat Pump
· High Demand
· Electric
· Vacation/Away: 2-28 days (or placed on hold indefinitely)
Plus...
· Premium grade anode rod with resistor extends the life of the tank
· 3/4" NPT water inlet and outlet; 3/4" condensate drain connections
· Incoloy stainless steel resistor elements
· Dry-fire protection
· Easy access, top mounted washable air filter
· 2" Non-CFC foam insulation
· Enhanced flow brass drain valve
· Temperature and pressure relief valve installed
· Design certified to NSF/ANSI 372 (Lead Content)
Warranty
· 10-Year limited tank and parts warranty
See Residential W arranty Certificate for complete information

Available in 15 & 30 Amps
Professional Prestige ProTerra Hybrid
40, 50, 65 and 80 - US Gallon Capacities
208-240 Volt / 1 PH Electric
LEED Points = 3

1Available with select models. 2WiFi broadband internet connection required. 3Source: Rheem Leak-Sensing Data; testing under a vacuum lock using 50-gallon tank, no expansion tank, average tank pressure of 40 psi, assuming no additional faucets are opened. 4Water leaks from the heater only, as tested across scenarios including a minimum of 5.5mL/hr v olume leak rate, using most common installation scenarios.

See specifications chart on next page.

IINNTTEEGGRRAATETDE DHOHMOEMCEOCMOFOMRFTO RT

PRINTED IN U.S.A. 09/20 WP FORM NO. HP-350-5CAN Rev. 2

Professional Prestige® ProTerra Hybrid Specifications

DESCRIPTION

NOMINAL RATED US GALLON US GALLON IMP. GALS CAPACITY CAPACITY CAPACITY

MODEL NUMBER

MODEL VARIANT

ENERGY INFO

FEATURES

ELECTRIC BREAKER
SIZE

UNIFORM ENERGY FACTOR
(UEF)

COMPRESSOR BTU/H

SOUND LEVEL (dBA)

UEF FIRST HR.
RATING G.P.H.

RECOVERY IN G.P.H 90° F RISE

TOTAL ELEMENT UNIT WATTAGE WATTAGE

MAX AMPS

SHIPPING WEIGHTS
UNIT APPROX. WT. SHIP WT. (LBS) (LBS.)

ProTerra with LeakGuard

40

36

33 CPROPH40 T2 RH375-SO 701345 30

3.75

4,200

49

60

26

4,500 5,000 21 157 174

50

45

42 CPROPH50 T2 RH375-SO 701354 30

3.75

4,200

49

67

27

4,500 5,000 21 178 218

65

59

54 CPROPH65 T2 RH375-SO 701363 30

3.85

4,200

49

75

27

4,500 5,000 21 225 262

80

72

67 CPROPH80 T2 RH375-SO 701355 30

4.00

4,200

49

87

27

4,500 5,000 21 244 281

ProTerra 30 Amp without LeakGuard

40

36

33 CPROPH40 T2 RH375-30 701361 30

3.75

4,200

49

60

27

4,500 5,000 21 157 174

50

45

42 CPROPH50 T2 RH375-30 701369 30

3.75

4,200

49

67

27

4,500 5,000 21 178 218

65

59

54 CPROPH65 T2 RH375-30 701370 30

3.85

4,200

49

75

27

4,500 5,000 21 225 262

80

72

67 CPROPH80 T2 RH375-30 701372 30

4.00

4,200

49

87

27

4,500 5,000 21 244 281

ProTerra 15 Amp without LeakGuard

40

36

33 CPROPH40 T2 RH375-15 701350 15

3.45

4,200

49

46

16

2,250 2,750 12 157 174

50

45

42 CPROPH50 T2 RH375-15 701358 15

3.75

4,200

49

52

16

2,250 2,750 12 178 218

65

59

54 CPROPH65 T2 RH375-15 701349 15

3.55

4,200

49

54

16

2,250 2,750 12 225 262

80

72

67 CPROPH80 T2 RH375-15 701356 15

3.70

4,200

49

67

16

2,250 2,750 12 244 281

I J

2" Clearance Needed for T&P Release
F
G

B

H A C E

D

DESCRIPTION

DIMENSIONS (SHOWN IN INCHES)

NOMINAL US GALLON CAPACITY

RATED US GALLON CAPACITY

IMP. GALS CAPACITY

MODEL NUMBER

A

B

C

40

36

33

CPROPH40

62-5/16 20-1/4

47

50

45

42

CPROPH50

61-3/4

22-1/4

47

65

59

54

CPROPH65

64-3/16 24-1/4

49

80

72

67

CPROPH80

74-3/16 24-1/4

59

D 3-5/8 3-5/8 3-7/8 3-7/8

E 39-5/8 39-5/8 42-3/8 42-3/8

F 23-3/8 25-3/8 27-1/2 27-1/2

G 20-1/2 22-1/2 24-5/8 24-5/8

H 78-7/8 78-5/8 81-1/8
91

I 22-3/8 24-3/8 26-1/2 26-1/2

J 23-1/4 25-9/16 27-3/8 27-3/8

2

Hybrid Water Heater Installation Guidelines to Provide Optimal Efficiency

Heater: Not Ducted
Room size: Larger than 700 ft3 (e.g. 7' x 10' x 10'). Requirements: No additional ventilation needed.

Heater: Not Ducted
Room size: Smaller than 700 ft3 (e.g. 7' x 10' x 10'). Requirements: Full louvered door OR two louvers top and bottom. See below.

Heater: Not ducted
Room: Small Closet Requirements: * Air gap under door equal to 18 in2 (0.75" clearance).
* Louver must be located the same height on door as the air exhaust on heater.
* Heater air exhaust must be positioned towards louver within one foot of door.

.75"

24"

Heater: Ducted with inlet OR outlet duct
Room size: Any size room Requirements: Air gap under door equal to 18 in2 (0.75" clearance)

Air exhaust

12" Max

Door

Heater: Ducted with inlet AND outlet duct
Room size: Any size room Requirements: No additional ventilation needed.

.75"

24"

3

Water

Residential Electric Professional Prestige ProTerra Hybrid Water Heaters

Hybrid Accessories List

PART NUMBER AP19134 AP20180 AP21365 AP17829 SP20882 SP20883 SP20884 SP20885 SP20886 SP20887 SP20888 SP20889 SP20890 UPGRADE KIT

DESCRIPTION Leak Sensor Shutoff Valve Inlet Duct Adapter Outlet Duct Adapter Earthquake Isolation Kit Vibration Isolation Kit 8" Diameter UL Certified Termination Kit 7" Diameter UL Certified Termination Kit 6" Diameter UL Certified Termination Kit 5" Diameter UL Certified Termination Kit 8" Rheem Approved Damper Kit 25' Flexible 8" Diameter Duct Kit Rigid Elbow Duct Kit

SP21111

Leak Sensor & Shutoff Valve Kit

USE FOR Automatic detection of internal and external leaks Automatic shut off of water supply to unit Allows for ducting to be connected on the top inlet Allows for ducting to be connected to the unit Installations in seismic regions Installation on non-concrete floors Termination to the outside or to the attic with 8" diameter Termination to the outside or to the attic with 7" diameter Termination to the outside or to the attic with 6" diameter Termination to the outside or to the attic with 5" diameter Exhaust only to the outside ducting configuration (no inlet duct) For up to 25' of ducting Installation in tight places where space needs to be minimized
Upgrade ProTerra 15 and 30 Amp models to protect your customers home from water damage with leak detection and auto shutoff valve

AP19134 - Leak Sensor

AP20180 - Shutoff Valve

AP21365 - Inlet Duct Adapter

AP17829 - Outlet Duct Adapter

SP20882 - Earthquake Isolation Kit

SP20883 - Vibration Isolation Kit

SP20884 - 8" Diameter UL Certified Termination Kit

SP20885 - 7" Diameter UL Certified Termination Kit

SP20886 - 6" Diameter UL Certified Termination Kit

SP20887 - 5" Diameter UL Certified Termination Kit

SP20888 - 8" Rheem Approved Damper Kit

SP20889 - 25' Flexible 8" Diameter Duct Kit

UPGRADE KIT (for ProTerra models without LeakGuard only) ­ Add leak detector and shuttoff valve to protect from water damage

SP20890 - Rigid Elbow Duct Kit

SP21111 - Leak Sensor & Shutoff Valve Kit

In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.

Rheem Canada Ltd./Ltée · 125 Edgeware Road, Unit 1 Brampton, Ontario L6Y 0P5 · www.rheem.ca

IINNTTEEGGRRAATETDE DHOHMOEMCEOCMOFOMRFTO RT

4
PRINTED IN U.S.A. 09/20 WP FORM NO. HP-350-5CAN Rev. 2


Adobe PDF Library 10.0.1 Adobe InDesign CS6 (Macintosh)