Nortek Global HVAC GXH48-60MSK4DH 4/5 Ton Inverter Split System Heat Pump - Technical Specifications
Submittal Document: GXH48-60MSK4DH
Product: 4/5 Ton Inverter Split System Heat Pump ODU
Features and Benefits
- High-efficiency heat pump system; up to 18 SEER and 10.5 HSPF
- Unparalleled heating performance rated to -22°F with 100% nominal capacity down to 17°F
- 100% cooling capacity up to 105°F
- Fully-inverter-driven compressor controlled in 1Hz steps, outperforming few-speed compressors
- Side discharge outdoor unit provides greater installation flexibility, requiring less space
- Capable of a braze-free installation, eliminating corrosive contaminants
- One system with two capacities set via the flip of a dip switch
- Long Life PVE oil that does not break down in the presence of moisture
- One of the quietest outdoor units on the market
- Outdoor unit is sea coast rated, showing no unexpected corrosion in 1500 hr salt spray test
- Control board indicates errors on an easy-to-read display; no counting flashes
- Compatible with most 24V heat pump thermostats; non-communicating
- Multi-level self-protection ensures a long, trouble-free equipment life
- Intelligent defrost ensures defrost operation only operates when needed
- Built-in base pan heater provides protection from freezing and ice build-up
- Built-in crankcase heater protects the compressor
- Fits standard mini-split-style outdoor unit wall brackets
- 10 Year, non-transferable, parts and compressor warranty; no registration requirement
- Includes Flexible Suction Line Connector for easily routing piping through the side or back
- Accumulator and oil separator protects the compressor
- Refrigerant Adjustment Tank removes or adds refrigerant to the circuit as needed
- Pre-charged for 31 feet of line set. No Refrigerant Adjustment Needed for Less Than 31'
- Copper-tube/aluminum fin outdoor and indoor coil
- Independent lab-tested and verified heating operation to -22°F
- Independent lab-tested and verified cooling operation to 118°F
Product Image Description: A large, rectangular outdoor unit with two stacked fan/coil sections on top, a control panel on the side, and a base. It is designed for side discharge.
System Ratings and Specifications
System Ratings
4 Ton | 5 Ton | |
---|---|---|
Rated Cooling Capacity: | 48,000 | 54,000 |
Rated Heating Capacity: | 48,000 | 54,000 |
Efficiencies
Metric | 4 Ton | 5 Ton |
---|---|---|
SEER: | 18 | 17 |
HSPF: | 10.5 | 10 |
EER (95°F): | 11 | 10.5 |
Power Supply
Parameter | 4 Ton / 5 Ton |
---|---|
Voltage (Min-Max): | 187-253 V |
MCA: | 31 A |
MOCP: | 45 A |
Ambient Operating Ranges
- Cooling: 5°F to 118°F
- Heating: -22°F to 75°F
- Max. Sound Pressure: 61 dB(A)
Outdoor Unit Data
Compressor
- Type: Inverter Rotary
- RLA: 19 A
- Model: QXAU-F516zX440A
- Oil: Polyvinylether (PVE)
Fan Motor
- Type: Brushless DC
- RLA: 0.75 A
- Model: SWZ150D
Physical Characteristics
- Net Weight: 308.7 lbs
- Gross Weight: 337.3 lbs
- Height: 53-5/8"
- Width: 39-3/8"
- Depth: 14-1/2"
Refrigerant Piping Data
- Refrigerant Type: R-410A
- Pre-charged Amount (Oz): 13.8 oz
- Pre-Charged Length (ft): 31.1 ft
- Additional amount (Oz/ft.): 0.32 oz/ft
- Max. Piping Length (ft): 98.4 ft
- Max. Piping Height (ft): 49.2 ft
- ODU Connection Size (Liquid): 3/8"
- ODU Connection Size (Gas): 3/4"
Dimensions and Installation Clearances
Outdoor Unit Dimensions
Front View: Width approximately 42-3/4 inches.
Side View: Height 53-3/4 inches, Depth 14-1/2 inches.
Top View: Width at center of mount approximately 24-1/2 inches, Depth at center of mount approximately 15-1/2 inches.
Typical Installation Minimum Clearances
- Front: Greater than 12 inches
- Side: Greater than 12 inches
- Top: Greater than or equal to 4 inches
- Rear: Greater than 40 inches
Note: Ensure the height of the wall in front is not shorter than the top of the unit. Refer to the installation manual for detailed guidance.
Installation Examples and Performance Charts
Covered Installation Examples
Example 1: Unit installed on a balcony or deck, showing minimum clearances of greater than 12 inches on the front and side.
Example 2: Unit installed near a house or building, showing minimum clearances of greater than 40 inches in the rear, greater than 3 inches in the front, and considerations for snow or water accumulation.
Heating Capacity Comparison (4 Ton)
This chart illustrates the heating capacity (BTU/h) of the "M-1 Ultra" model against "Company B" and a "16 SEER" benchmark across a temperature range from -22°F to 48°F. The "M-1 Ultra" demonstrates superior heating performance, maintaining a higher capacity at colder temperatures, particularly from -22°F up to 18°F, compared to the other models.
Heating Capacity Comparison (5 Ton)
This chart presents a similar comparison for the 5-ton model. The "M-1 Ultra" again shows a distinct advantage in heating capacity at low ambient temperatures, outperforming "Company B" and the "16 SEER" benchmark from -22°F through 38°F.