Ubiquiti Inc. UDR7 Digital Transmission Radio SWX-UDR7 SWXUDR7 udr7
Maximum Permissible Exposure FCC Part 2 Sections §2.1091 and §2.1093 Test Requirement(s): §15.407(f): U-NII devices are subject to the radio frequency radiation exposure requirements specified in §1.1307(b), §2.1091 and §2.1093 of this chapter, as appropriate. All equipment shall be considered to operate in a "general population/uncontrolled" environment. RF Exposure Requirements: §1.1307(b)(1) and §1.1307(b)(2): Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission's guidelines. RF Radiation Exposure Limit: §1.1310: As specified in this section, the Maximum Permissible Exposure (MPE) Limit shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in Sec. 1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of Sec. 2.1093 of this chapter. MPE Limit: EUT's operating frequencies @ Bluetooth 2402 2480 MHz; WiFi 2412 2462 MHz; UNII-1 5180 5240 MHz; UNII-2a 5260 5320 MHZ; UNII-2c 5500 5720 MHz; UNII-3 5745 5855 MHz; UNII-5 5955 6415 MHz; UNII-6 6435 6515 MHz; UNII-7 6535 6875 MHz; UNII-8 6895 7115 MHz Limit for Uncontrolled exposure: 1 mW/cm2 or 10 W/m2 Equation from page 18 of OET 65, Edition 97-01 S = PG / 4R2 or R = (PG / 4S) where, S = Power Density (mW/cm2) P = Power Input to antenna (mW) G = Antenna Gain (numeric value) R = Distance (cm) Test Results: Frequency Con. Pwr. (MHz) (dBm) 2480* 2442* 5240 5320 5530 5775* 6905* 5.18 29.99 26.73 22.88 22.96 27.20 22.97 Con. Pwr. (mW) 6.60 997.70 470.98 194.09 197.70 524.81 198.15 Ant. Gain (dBi) 4 5 7 7 7 7 6 FCC Pwr. Ant. Gain Density numeric (mW/cm2) 2.51 0.00 3.16 0.40 5.01 0.30 5.01 0.12 5.01 0.13 5.01 0.34 3.98 0.10 Limit (mW/cm2) 1.0 1.0 1.0 1.0 1.0 1.0 1.0 Margin -0.0 -0.60 -0.70 -0.88 -0.87 -0.66 -0.90 Distance (cm) 25 25 25 25 25 25 25 Result Pass Pass Pass Pass Pass Pass Pass *Simultaneous Transmission (Worse case): 0.84 1.0 -0.16 25 Pass The safe distance for SWX-UDR7 where Power Density is less than the MPE Limit listed above was found to be 25 cm. This device does not perform power tune-ups, therefore the maximum power is used for this analysis.Microsoft Word 2016 Microsoft Word 2016