Bestway #58230 Pool+Drain Pump Owner's Manual
Model: #58230
Specifications: 220-240V~50Hz, 80W, IPX8, Max Head 2.2m, Min Head 0.02m, Max Immersion Depth 1.22m
Contact Information
Shanghai: Bestway Global Holding Inc. No.3065 Cao An Road, Shanghai, 201812, China. Tel: +86 21 6913 5588, Fax: +86 21 5913 8383, Email: info@bestway-shanghai.com
Hong Kong: Bestway (Hong Kong) International Ltd. Suite 713, 7/Floor, East Wing, Tsim Sha Tsui Centre, 66 Mody Road, Kowloon, Hong Kong. Tel: +852 2997 7169, Fax: +852 2997 7869, Email: info@bestway-hongkong.com
Europe: Bestway (Europe) S.r.l. Via Resistenza 5, 20098 San Giuliano M.se (Mi) - Italy. Tel: +39 02 9884 881, Fax: +39 02 9884 8828, Email: info@bestway-europe.com
Central & South America: Bestway Central & South America Ltda Salar Ascotan 1282, Parque Enea, Pudahuel, Santiago, Chile. Tel: +562 3203 6438, Fax: +562 3203 6409, Email: info@bestway-southamerica.com
U.S.A.: Bestway (USA) Inc. 3249 E. Harbour Drive, Phoenix, Arizona 85034, United States of America. Tel: +1 480 838 3888, Fax: +1 480 304 3349, Email: sales@bestway-northamerica.com
Australia: Bestway Australia Pty Limited Unit 10/71-83 Asquith Street, Silverwater, NSW 2128, Australia. Tel: +61 2 9037 1388, Fax: +61 2 9737 9423, Email: info@bestway-australia.com
WARNING: IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
WARNING – The pump is to be supplied by an isolating transformer or supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 mA.
WARNING – The power source on the wall of building should keep more than 4m away from pool and at a height of 1.2m at least.
WARNING – The appliance must be supplied by earthed power source.
WARNING – RISK OF ELECTRIC SHOCK – The pump cannot be used while people are inside the pool.
DO NOT BURY CORD. Locate cord to minimize abuse from lawn mower, hedge trimmers, and other equipment.
WARNING – TO REDUCE THE RISK OF ELECTRIC SHOCK – The supply cord cannot be replaced. If the cord is damaged the appliance should be scrapped.
WARNING - Extension cords can't be used.
CAUTION – This pump is for use with storable pools only. Do not use with permanently-installed pools. A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity. A permanently-installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage.
IMPORTANT – Using the pump with an unmatched electrical supply is dangerous and will result in catastrophic failure of pump.
RISK OF ELECTRIC SHOCK – When working with electricity, turn the electrical power off at the circuit breaker and lock breaker door. Failure to do so will result in increased risk of shock, injury and possibly death.
DO NOT REMOVE THE GROUNDING PRONG OR MODIFY THE PLUG IN ANY WAY. DO NOT USE ADAPTOR PLUGS. Consult a qualified electrician for any questions related to the validity of your plugs grounding.
Handle the pump with care. Do not pull or carry the pump by the power cord. Never pull a plug from the outlet by yanking the power cord. Keep cord free from abrasions. Sharp objects, oil, moving parts, and heat should never be exposed to the pump.
WARNING – This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Usage and Maintenance Guidelines
Cleaning and user maintenance must be performed by an adult above 18 years old who is familiar with the risk of electric shock.
Caution: Read the instruction before using the appliance and installation/reassemble each time.
WARNING – RISK OF ELECTRIC SHOCK – Do not put the plug into the water.
NOTE: Please examine equipment before use. Notify Bestway at the customer service address listed on this manual for any manufacturing defect or missing parts at the time of purchase. Verify that the equipment components represent the pump model that you had intended to purchase.
NOTE: The plug of pump shall be at least 3.50m away from the pool.
NOTE: Atmospheric conditions may affect the performance and life span of your pump. Unnecessary wear and tear may occur during periods of cold, heat and exposure to sun. Whenever possible shelter the pump from these conditions.
It is imperative to change as soon as possible all the deteriorated parts. Only use the parts approved by the manufacturer.
IMPORTANT: Always remember to unplug the drain pump after each using.
NOTE: Assembly and disassembly by adults only.
NOTE: The pump is used for cleaning and other maintenance of swimming pools.
Do not plug or unplug the appliance if hand is wet.
Always unplug the appliance:
- On raining days
- Before cleaning or other maintenance
- When left unattended on holidays
When the appliance will be not used for long time, such as in the winter, the pump should be disassembled and stored indoor.
Safekeeping the instruction. For reconstruction the pool set every time, please always refer to the instructions.
If instruction is missed, please contact with Bestway or search it in website: www.bestway-service.com
NOTE: This product is not intended for commercial use.
SAVE THESE INSTRUCTIONS.
Parts Reference Overview
Before assembling the drain pump, become familiar with all parts. (See Figure 1)
Part Number | Description |
---|---|
P6005 | Hose Seal Ring |
P6124 | Hose Clamp |
P6556 | Hose |
P6555 | Adaptor |
P6H565 | Adaptor |
NOTE: To order spare parts for the drain pump, list the part No.
Pump Installation and Operation
- Connect the provided hose to the drain pump by fastening the hose clamp. (See Figure 2)
NOTE: Two types of hose adaptors are provided to be used with different garden hoses, see Figure 3 & Figure 4 for assembly.
- Vertically place the drain pump into the pool with the other end of hose to the drain area. (Check local regulations for drainage by-laws)
NOTE: Do not put the plug into the pool.
- To turn on the pump, insert the plug into a proper socket.
NOTE: When the water level of the pool is less than 2cm, do not use the drain pump.
NOTE: Keep the drain pump vertical at all times.
NOTE: Do not dry run the pump.
Figure 1 Description: Illustrates the Bestway Pool+Drain Pump (P6556) and its associated parts: Hose Clamp (P6124), Hose Seal Ring (P6005), and Adaptors (P6555, P6H565).
Figure 2 Description: Shows the pump (P6556) connected to the hose (P6124) using a hose clamp.
Figure 3 Description: Depicts an American garden hose connected to the pump using adaptor P6555.
Figure 4 Description: Depicts a European garden hose connected to the pump using adaptors P6H565 and P6555.
Pump Maintenance and Storage
CAUTION: YOU MUST ENSURE THE DRAIN PUMP IS UNPLUGGED BEFORE PERFORMING MAINTENANCE OR SEVERE RISK OF INJURY OR DEATH EXISTS.
- Unplug the pump.
- Loosen the hose clamps, and remove the hose from the drain pump.
- Dry the pump with a cloth and store in a dry location out of reach from children.