General Electric Magne-blast Circuit Breakers

These documents provide comprehensive technical information for General Electric's Magne-blast circuit breakers. They cover installation, operation, maintenance, adjustments, and troubleshooting for various models, including those with MS-9 and MS-13 mechanisms.

The manuals detail specific series such as the AM 4.16-75 and AM-2.4/4.16 lines, offering essential guidance for service personnel and engineers working with this electrical equipment.

PDF preview unavailable. Download the PDF instead.

Adobe Acrobat Pro DC 15.7.20033 Adobe PDF Scan Library 3.2

Related Documents

PreviewGeneral Electric Secondary Unit Substation Transformers Instructions
Comprehensive instructions for the installation, operation, and maintenance of General Electric Secondary Unit Substation Transformers. Covers receiving, handling, storage, installation, connections, testing, and troubleshooting.
PreviewGeneral Electric Winding Temperature Equipment (Type AWR/AW) - Operation and Installation Guide
Comprehensive guide to General Electric's Type AWR and AW winding temperature equipment, detailing their function, installation, operation, and adjustment for transformer monitoring. Covers local and eye-level indicators, and remote detectors.
PreviewGeneral Electric ET-16 and ET-17 Indicating Lamps: Instructions and Specifications
This document provides instructions, specifications, ratings, and ordering information for General Electric's ET-16 (incandescent) and ET-17 (neon) indicating lamps, designed for panel mounting on switchboards.
PreviewGeneral Electric MicroVersaTrip RMS-9 Conversion Kit Installation Instructions for AK-15/25 Circuit Breakers
Detailed instructions for installing the General Electric MicroVersaTrip RMS-9 Solid State Overcurrent Trip Device conversion kit on AK-15 and AK-25 series low-voltage power circuit breakers. Covers preparation, installation, modifications, and testing.
PreviewGEH-5201C Synchronous-Motor Control: CR192 µSPM Application and Instructions
Comprehensive application notes and instructions for the General Electric GEH-5201C Synchronous-Motor Control system, featuring the CR192 Microprocessor-based Starting and Protection Module (µSPM). Covers operation, installation, programming, and troubleshooting for industrial motor control.
PreviewWorkstationST Alarm Server Instruction Guide
This instruction guide provides comprehensive details on the WorkstationST Alarm Server, covering its features, configuration, and operation. Learn about alarm states, event handling, system topology, and troubleshooting.
PreviewGeneral Electric AKR-75/100 and AKS-50 Low Voltage Power Circuit Breaker Maintenance Manual
Detailed maintenance manual for General Electric's AKR-75/100 and AKS-50 series low voltage power circuit breakers, covering inspection, operation, maintenance, troubleshooting, and accessories.
PreviewGE AK/AKR Low Voltage Power Circuit Breaker Parts & Identification Guide
Explore the comprehensive guide to General Electric AK and AKR series low voltage power circuit breaker parts, identification, and nomenclature. This document details components, trip units, and nameplate data for commercial, industrial, and utility applications.