READ BEFORE INSTALLATION

(1) INSTRUCTION MANUAL 46 16 6.4 1.8 7.2 ft 12 ft 19 ft 36 ft 3 ft 5 ft 8 ft 15 ft Center Beam (Foot Candles) Beam Diameter Beam Angle = 100º LIGHTING DISTRIBUTION Before beginning installation of this product, make sure all parts are present. Compare parts with package contents list and diagram.

Manual - Feit Electric

RISK OF FIRE OR ELECTRIC SHOCK: Install this product only in luminaires that have the construction features and dimensions shown in the photographs and/or ...

IMPORTANT SAFETY INSTRUCTIONS AND INSTALLATION ...

If the product fails within the warranty period, please contact Feit Electric at info@feit.com, visit feit.com/contact-us or call 1-866-326-BULB (2852) for instructions on ...


File Info : application/pdf, 4 Pages, 221.12KB

PDF 315379278 Installation
ITEM # LEDR56/NL/5CCTCA
Questions, problems, missing parts? Before returning to the store, call Feit Electric Customer Service 8 a.m. - 5 p.m., PST, Monday-Friday 1-866-326-BULB (2852)

IMPORTANT SAFETY INSTRUCTIONS AND INSTALLATION GUIDE

READ BEFORE INSTALLATION
SAVE THESE INSTRUCTIONS
Please read and understand this entire manual before attempting to assemble, operate or install this product. This product must be installed in accordance with any applicable installation code(s) by a qualified electrician or person familiar with the construction and operation of the product and the hazards involved.

WARNING

CAUTION

· RISK OF FIRE OR ELECTRIC SHOCK: The electrical rating of this product is 120VAC.
· RISK OF FIRE OR ELECTRIC SHOCK: Install this product only in luminaires that have the construction features and dimensions shown in the photographs and/or drawings in this manual.
· To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
· RISK OF SHOCK ­ DISCONNECT POWER BEFORE INSTALLATION
· Do not make or alter any open holes in an enclosure of wiring or electrical components during installation.
· THIS DEVICE IS NOT INTENDED FOR USE WITH EMERGENCY EXITS.
· RISK OF FIRE OR ELECTRIC SHOCK: LED Recessed Downlight with Trim installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.

To avoid possible electrical shock, be sure that the power is turned off at the fuse box or circuit breaker before installing or servicing the product. For your safety, read and understand the instructions completely before beginning installation.

Supplier's Declaration of Conformity: 47 CFR § 2.1077 Compliance Information Responsible Party: Feit Electric Company 4901 Gregg Road, Pico Rivera, CA 90660, USA 562-463-2852 Unique Identifier: FEIT ITEM # LEDR56/NL/5CCTCA
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Any changes or modifications not expressly approved by the manufacturer could void the user's authority to operate the equipment.

WARRANTY

This product is warrantied to be free from defects in workmanship and materials for up to five years from date of purchase. If the product fails within the warranty period, please contact Feit Electric at info@feit.com, visit feit.com/contact-us or call 1-866-326-BULB (2852) for instructions on replacement or refund. REPLACEMENT OR REFUND IS YOUR SOLE REMEDY. EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, ANY IMPLIED WARRANTIES ARE LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IS HEREBY EXPRESSLY EXCLUDED. Some states and provinces do not allow the exclusion of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state or province to province.

REV003

FEIT ELECTRIC COMPANY | PICO RIVERA, CA | 1-866-326-BULB (2852) | FAX (562) 908-6360 | www.feit.com

1

PACKAGE CONTENTS
Before beginning installation of this product, make sure all parts are present. Compare parts with package contents list and diagram. If any part is missing or damaged, do not attempt to assemble, install or operate this product.

COMPONENTS INCLUDED

A

A (1) MEDIUM BASE ADAPTER

B (1) RECESSED DOWNLIGHT

C (1) INSTRUCTION MANUAL

B

PRODUCT ELECTRICAL RATINGS
120 V / 60 Hz, XX mA, 11.1 W
SUITABLE FOR DAMP LOCATIONS Suitable for Type IC Housings and Non-IC Housings. Continuous dimming between 5% - 100% with most dimmers

LIGHTING DISTRIBUTION

Center Beam (Foot Candles)

Beam Diameter

3 ft

46

7.2 ft

5 ft

16

12 ft

8 ft

6.4

19 ft

15 ft

1.8

36 ft

Beam Angle = 100º

FEIT ELECTRIC COMPANY | PICO RIVERA, CA | 1-866-326-BULB (2852) | FAX (562) 908-6360 | www.feit.com

2

HOW TO SELECT YOUR LIGHT COLOR OR NIGHTLIGHT
This product comes with a dual feature that allows you to select between downlight mode and nightlight mode. · Downlight mode provides a selection of five color temperatures. · Nightlight mode provides low light output at a soft color temperature.

Soft White Bright White Neutral White Cool White

2700K

3000K

3500K

4000K

Daylight 5000K

NOTICE:

PICK YOUR FAVORITE LIGHT COLOR BEFORE INSTALLING

· You can lock in one color temperature. · When the slide switch is set to SW (Soft White),
the color temperature is set at 2700K. · When the slide switch is set to BW (Bright White),
the color temperature is set at 3000K.

· When the slide switch is set to NW (Neutral White), the color temperature is set at 3500K.
· When the slide switch is set to CW (Cool White), the color temperature is set at 4000K.
· When the slide switch is set to DL (Daylight), the color temperature is set at 5000K.

HOW TO SWITCH TO NIGHTLIGHT MODE
· Toggle the wall switch to power on the light. · At initial light up, the product is set to downlight mode. · To transition to nightlight mode, toggle the wall switch off and back on within 2 seconds. · To transition back to downlight mode, toggle the wall switch off and back on within 2 seconds

FEIT ELECTRIC COMPANY | PICO RIVERA, CA | 1-866-326-BULB (2852) | FAX (562) 908-6360 | www.feit.com

3

INSTALLATION INTO EXISTING RECESSED FIXTURE

NOTE: For use with 5 in. and 6 in. recessed housings (housing sold separately)

1 Turn off the power at the switch and fuse box or circuit breaker.
2 Remove the existing trim installed in the recessed housing (if necessary).

6 Insert the torsion springs into the fixture housing brackets. When installing the product into a 5 in. recessed housing, the torsion spring must be moved. Unscrew the torsion spring from the 6 in. position and move to the 5 in. position.

3 If applicable, slide the lampholder bracket to its upward maximum position. If necessary, remove the lampholder mounting bracket by removing the wing nut and the lampholder from the bracket, then attach the provided label to the existing luminaire.
Remove the lamp holder bracket (if necessary)

Wing nut
4 Install the medium base adapter into the socket.

NOTE: Select preferred light color before installing.

5 Connect the two terminals together.

For 5 in. recessed housings For 6 in. recessed housings
7 Gently push the product in until it is flush to the ceiling.

FEIT ELECTRIC COMPANY | PICO RIVERA, CA | 1-866-326-BULB (2852) | FAX (562) 908-6360 | www.feit.com