User Manual for MARTINDALE ELECTRIC models including: TB118KIT1 Complete Electrical Safety Kit for Gas Engineers, TB118KIT1, Complete Electrical Safety Kit for Gas Engineers
29 mars 2022 — LOKKITGAS1. ○ Four essential locking off devices, LOK10, LOK11, LOK7 for. MCBs and LOKFS1 for fused spurs. ○ Padlock, pen tag and carry case. VIPD138-S.
File Info : application/pdf, 2 Pages, 613.93KB
DocumentDocumentTB118KIT1 Complete electrical safety kit for gas engineers Technical Data Key features z Complete electrical safety kits for gas installation and service engineers z All in one solution for earth verification, locking off and proving dead z Includes voltage indicator, proving unit, locking off devices and earth checker z Slimline and miniature push pin MCB lock outs and fused spur locking off device z Essential for compliance with Electricity at Work Regulations for safe working and TB118 OInv2e0rv1i8ewGagsoeSsahfeerReegister Technical Bulletin 118 was amended. The changes require new test procedures to keep service engineers safe from electrical hazards. Starting from July 2020 Gas Safe registration will require knowledge and competency in how to safely isolate the electrical supply to appliances. Martindale TB118KIT1 includes all the essential test tools for gas safety engineers to achieve compliance. The new kit combines easy to use tools for live voltage indication and earth loop verification together with fused spur and MCB locking off devices in a high quality soft carry case. The full kit compromises of: LOKKITGAS1 z Four essential locking off devices, LOK10, LOK11, LOK7 for MCBs and LOKFS1 for fused spurs z Padlock, pen tag and carry case VIPD138-S z Voltage indicator and matching proving unit for safe and simple voltage indication z Combination carry case EZ650 z Earth loop resistance and polarity checker for socket and spur testing TC88 z Soft carry case with shoulder strap Specifications TB118KIT1 Complete electrical safety kit for gas engineers VI13800 Voltage Indicator Electrical Nominal voltage range: 50 - 600V DC/AC rms Nominal voltage threshold indications: 50, 100, 200, 400 V DC/AC rms Voltage threshold tolerance: Conforms to BS EN 61243-3 Internal impedance at ELV a.c.: 214k Polarity & voltage indication: 12V DC/AC rms AC/DC voltage detection: automatic Range detection: automatic Response time: <0.1s Frequency range: DC, 1 - 400Hz Test current: < 3.5mA at 600V DC/AC rms Duty ratio: 30s ON (operated) / 240s OFF (recovery) Environmental Temperature & Humidity (Operating & Storage): -10°C to 55°C 85% R.H. Altitude: up to 2000m General Power: From circuit under test Dimensions: 205(L) x 67(W) x 27(D) mm Weight: 130g approx. Safety Conforms to BS EN 61243-3 CAT IV 600 V Class II, Double Insulation Pollution Degree 2 IP rating: IP54 EMC Conforms to BS EN 61326-1 PD440S Proving Unit Output voltage: 440V nominal Output frequency: 50Hz nominal Environmental Operating temperature: -10°C to 40°C at max. 70% R.H. Altitude: up to 2000m Pollution degree: 2 General Power: internal batteries Internal batteries: 6 x 1.5V, AA alkaline batteries (IEC LR6, NEDA 15A) Dimensions: 143 x 84 x 50mm. Weight packed: 400g approx. with batteries Includes: 6 x 1.5V AA alkaline batteries, instructions EZ650 Advanced Socket and Spur Tester EZ650 E-Ze Check Xtra Pro is supplied with an IEC socket with an interchangeable 3 pin adaptor and a 3 way flying lead with croc clips allowing testing at sockets, fused spurs, light fittings, junction boxes and terminals. Nominal operating voltage: 230V Frequency: 50Hz Non-trip Earth loop impedance ranges: 0-1.7-5-10-100-200-500 Earth loop threshold accuracy: ±(10% + 0.3)* Voltage low indication: <195V ± 5% Voltage high indication: >270V ± 5% Earth neutral voltage high indication: >30V ± 5% Open earth indication: >500 Temperature Range: -10 to 40°C, non-condensing Dimensions: 315mm x 260mm x 85mm Weight: Approx 250g Power supply: From mains Power consumption: <2.5W Overvoltage category: Cat II / 300V Pollution degree: 2 Safety: Complies with BS EN 61010-1 * Note: Measurement accuracy can be affected by highly inductive or capacitive loads distributed on the supply LOKKITGAS1 Gas Engineer Lockout Kit The 8 piece lock out kit contains the following items: 1 x Padlock with unique key (PAD11RD) 1 x Steel safety hasp (LOKHASP25) 1 x Slimline grey isolation lock (LOK7) 1 x Red miniature push pin MCB lock (LOK11) 1 x Yellow push pin MCB lock (LOK10) 1 x "Equipment Locked Out" tag which can be overwritten 1 x Black marker pen (LOKMP) 1 x Soft carry case (TC55) Included EZ650 Earth loop impedance & socket tester, LOKKITGAS1 Gas engineer lockout kit, VIPD138-S Voltage indicator & proving unit kit, TC88 Soft carry case Optional Accessories TAG4 Pack of 10 lock out kit tags Martindale Electric Co. Ltd. Metrohm House, 12 Imperial Park, Imperial Way, Watford WD24 4PP. T: 01923 441717 F: 01923 446900 www.martindale-electric.co.uk sales@martindale-electric.co.uk Ver. C1.0 Due to policy of continuous development, Martindale Electric reserves the right to alter equipment specification and description outlined in this document without prior notice. No part of this document shall be deemed to be part of any contract for the equipment unless specifically referred to as an inclusion within such contract. © 2022 Martindale Electric Co. Ltd.