Options for use with 301EM-20 Break glass manual switch option for 301EM 301EM-20 light stack assembly with red lens, horn (85-103 dB), voltage rating, 24VDC LED Light...
Oxygen, Toxic & Combustible Gas Controller. User Friendly. • Zero maintenance. • Automatic quick self-test and warm-up. • Continuous alphanumeric display.
Carbon dioxide (CO2) monitor, duct mount, network, temp and rH, display. IAQ-DNC-TRH-D. 1508A2021. Carbon dioxide (CO2) monitor, duct mount, network, ...
Honeywell Analytics 2015 Product Guide Commercial Gas Detection Contact Information USA 405 Barclay Blvd. Lincolnshire, IL 60069 USA Order Status, Pricing Information and Product Availability Tel: +1.888.955.2585 (press 1) Order Placement or Making Changes to an Order Email: hasales.us@honeywell.com Fax: +1.847.955.8210 Product Information and Application Questions Tel: +1.888.955.2585 (press 1) Email: hasales.us@honeywell.com Product Information, Application Support & Written Quotations Call or email your Regional Sales Managers Technical Support Tel: +1.888.955.2585 (press 2) Email: haservice.workshop.us@honeywell.com Latin & South America Marginal da Rodovia dos Bandeirantes, 100 - Distrito Industrial Jundiaí, São Paulo Brazil ZIP: 13213-008 Tel: Fax: Email: +55 11 3309 1030 +55 11 3309 1005 ha.latinamerica@honeywell.com Canada 2840 2nd Ave SE Calgary, Alberta, Canada T2A 7X9 3580 Rue Isabelle Unit 100 Brossard, Quebec, Canada J4Y 2R3 Order Status, Pricing Information and Product Availability Tel: +1.800.563.2967 (select language + press 1) Order Placement or Making Changes to an Order Email: hasales.canada@honeywell.com Fax: +1.450.619.2448 Product Information and Application Questions Tel: +1.800.563.2967 (select Language + press 1) Email: hasales.canada@honeywell.com Product Information, Application Support & Written Quotations Call or email your Regional Sales Managers Technical Support Tel: +1.800.563.2967 (select language + press 2) Fax: +1.450.619.2447 Email: haservice.canada@honeywell.com 2 When placing an order, please reference the Order Number (not the Model Number) where applicable. PG1100-9-NCL Table of Contents E³Point .....................................................2 301C.........................................................4 IAQPoint2.................................................5 301EM-20 & 301IRFS..............................8 Self-Contained Breathing Apparatus (SCBA)..............................................11 SQN8x Sample Draw.............................12 AirScanTM IR-F9.....................................14 Sensepoint® XCD...................................15 Sensepoint® XCD RTD...........................18 Sensepoint® XCD RFD...........................21 ToxyPoint...............................................23 Midas® Extractive Gas Detector............24 Commercial Accessories.......................28 Calibration Equipment...........................30 Service Information................................32 PG1100-9-NCL Note Please note that specifications and exact product offering are subject to change without notice. Additonal shipping and handling fees may apply for some products. This publication is not intended to form the basis of a contract. When placing an order, please reference the Order Number (not the Model Number) where applicable. 1 E³Point Toxic & Combustible Gas Monitor CO, NO2, H2S, H2, O2, CH4, C3H8 Sensor Cartridge Remote Sensor Make your operation run more intelligently to protect people, property and your bottom line. Protect parking structures, loading docks, transport terminals, hospital/ambulance bays, car washes, battery charging rooms and hydrogen tanks, commercial kitchens, indoor stadiums, outbuildings and more. Note: Non-branded versions of this product are available upon request. Flexible Operation · Comes in standalone, standalone with remote (dual gas mode) or network versions · Connects to analog or digital systems · Works with virtually any BAS including BACnet or Modbus · Wall or duct mount · Factorycalibrated cartridges Cost Effective · Saves energy through Demand Control Ventilation (DCV) · Simplifies installation/maintenance through plugnplay sensor · Remote sensor option provides dual gas monitoring (standalone version only) · Optimizes BAS, fire, ventilation and other security systems Versatile Communications · Works through BAS to improve fault diagnostics and collect data on gas concentation levels, sensor condition, etc. · Couple with 301C to log data and daisychain up to 96 E³Point units Advanced Sensing Technology · Detects CO, NO2, O2, H2, H2S, CH4, C3H8 · Advanced electrochemical (for toxic gases) and catalytic bead (for combustible gases) sensor performance · Uses patented Reflex® and smart cartridge technologies Range of Accessories · Factorycalibrated replacement cartridges · Power transformer · Vandalresistant steel wire detector guards · Tamperproof screws · Horns and strobes Applications · Parking Structure · Loading Dock Transport Terminal · Golf Cart Maintenance · Battery Charging Area · Maintenance Garage · Hospital/Ambulance Bay · Fire/Police Station · Car Wash · Battery Charging Rooms · H2 & Hydrogen Tanks · Commercial Kitchen C3H8 · Boiler rooms Certifications · Intertek Classified to: UL 61010-1; and CSA C22.2 No. 61010-1-04 · COLA (City of Los Angeles) approved for carbon monoxide detection in commercial buildings and parking garages 2 When placing an order, please reference the Order Number (not the Model Number) where applicable. PG1100-9-NCL E³Point Toxic & Combustible Gas Monitor E³Point Analog (Single or Dual Gas) E³Point without sensor, wall mount, analog, 24 Vac/Vdc E³Point without sensor, wall mount, analog, 120 Vac E³Point without sensor, duct mount, analog, 24 Vac/Vdc Note: Sensor cartridge sold separately (see list below). Model Number E3SA E3SAH E3DA E³Point Network (Single Gas, BACnet or Modbus Selectable) E³Point without sensor, wall mount, Modbus/BACnet, 24 Vac/Vdc E³Point without sensor, duct mount, Modbus/BACnet 24 Vac/Vdc Note: Sensor cartridge sold separately (see list below). Model Number E3SM E3DM E³Point Sensor Cartridges Carbon monoxide (CO); -20° to 50°C (-4° to 122°F) Nitrogen dioxide (NO2); -40° to 50°C (-40° to 122°F) Hydrogen sulfide (H2S); -40° to 50°C (-40° to 122°F) Hydrogen (H2); -40° to 50°C (-40° to 122°F) Oxygen (O2); -40° to 50°C (-40° to 122°F) Methane (CH4); -40° to 50°C (-40° to 122°F) Propane (C3H8); -40° to 50°C (-40° to 122°F) Model Number E3SCO E3NO2 E3H2S E3H2 E302 E3M E3P E³Point Remote Gas Sensor (For use with E³Point Analog Units Only) E³Point remote sensor, carbon monoxide (CO) E³Point remote sensor, nitrogen dioxide (NO2) E³Point remote sensor, hydrogen sulfide (H2S) E³Point remote sensor, hydrogen (H2) E³Point remote sensor, oxygen (O2) E³Point remote sensor, methane (CH4) E³Point remote sensor, propane (C3H8) Model Number E3SRMCO E3SRMNO2 E3SRMH2S E3SRMH2 E3SRMO2 E3SRMM E3SRMP E³Point Accessories Protective wire guard for E³Point E³Point tamper-proof kit Splash guard enclosure Bump test kit; includes balloon adapter and quad gas cylinder: H2S (40 ppm), CO (200 ppm), CH4 (2.5%), O2 (10%) Test cap with hose for E³Point Regulator for 58 L / 103 L cylinder (0.5 LPM) for E³Point Polyurethane tubing, 6 mm O.D. x 4 mm I.D., 1 ft. / 30 cm Model Number E3PT-CAGE E3T-PK ECLAB TEST-1A Order Number 1309A0042 1309A0043 1309A0049 Order Number 1309A0047 1309A0051 Order Number 1309A0038 1309A0037 1309A0035 1309A0039 1309A0036 1309A0040 1309A0041 Order Number 1309A0060 1309A0057 1309A0058 1309A0059 1309A0056 1309A0061 1309A0062 Order Number 1309-0071 1309K0001 1309K0003 TEST-1A 131635-L3 M-502875 M-502730 PG1100-9-NCL When placing an order, please reference the Order Number (not the Model Number) where applicable. 3 301C Oxygen, Toxic & Combustible Gas Controller The 301C Controller continuously monitors and controls toxic gases, combustible gases, and oxygen hazards. Designed for installation and operational simplicity, the 301C reduces the cost of installation and ownership. Using an addressable RS-485 Modbus communication protocol, the 301C uses daisy chain wiring requiring only 2 pairs of wires to connect up to 96 transmitters on the 3 input channels. This simplifies installation, in turn lowering costs. The 301C's zoning and averaging abilities significantly reduce operational and maintenance costs. Note: Non-branded versions of this product are available upon request. User Friendly · Zero maintenance · Automatic quick self-test and warm-up · Continuous alphanumeric display Inexpensive and Reliable · Low installation costs · Allows for up to 126 zoning groups which can save energy and extend fan and relay life · Manages up to 180 events with programmable latching alarms Flexible Operation · Modbus compatible; with BACnet/IP available · Interchangeable transmitters able to detect different gases · Expands to handle up to 96 transmitters or relay modules · Programmable time delays · Integrated time clock enables scheduling of system operations Safety Measures · Full array of visual indicators and integrated 65dBA alarm levels · Fully programmable relays (can be set as fail-safe or not) Beneficial Options · Available in a heavy duty industrial housing · Datalogging option Applications All commercial building areas requiring multi-point gas monitoring Certifications · Intertek Listed to: UL 61010-1; and CSA C22.2 No. 61010-1-04 301C Gas Controllers 301C Controller with datalogger, BACnet/IP output, ABS polycarbonate enclosure 301C Controller with datalogger, ABS polycarbonate enclosure 301C Controller, ABS polycarbonate enclosure Order Number 301-C-DLC-BIP 301-C-DLC 301-C 301C Gas Controller Interface Modules 301-ADI analog digital input converter (4-20mA to Modbus RS-485) 301AP annunciator panel for 301C Controller 301-R8 relay module with 8 relays, failsafe 301-R8 relay module with 8 relays 420I digital analog output converter, Modbus RS-485 to 4-20mA Order Number 301-ADI 301-AP 301-R8-FS 301-R8 420-I 4 When placing an order, please reference the Order Number (not the Model Number) where applicable. PG1100-9-NCL Non Display Unit View at-a-glance normal or fault status Ductmount Unit Gain maximum flexibility for installation IAQPoint2 Indoor Air Quality Monitor CO2 or VOC + temperature/humidity monitoring Improve indoor air quality and cut energy costs with CO2 or VOC + temp/humidity monitoring for demand control ventilation. IAQPoint2 features a fully functional, multi-color, touch screen interface, the first of it's kind. IAQPoint2 operates on +24 Vac/Vdc. Analog output is 4-20 mA or 2-10 Vdc, switch selectable. Digital output is BACnet/ Modbus selectable or LonWorks. Available in wall mount and duct mount configurations. Note: Non-branded versions of this product are available upon request. UserFriendly Touchscreen Operation · Menu driven, customizable, easytonavigate display · Large 1.9 x 2.6 in. (4.9 x 6.5 cm) VGA screen with easytoread LCD digits and graphical display Flexible, MoneySaving Design · Simple wall or ductmount · Multianalog or digital (BACnet, Modbus) options · DC and AC power; fits standard junction box · 5 year sensor life with automatic selfcalibration · Adjustable setpoints and optional relay for local fan activation 3in1 Monitoring · Choose reliable CO2 or VOC sensing technologies · Optimize room comfort through temperature control Green Attributes · Obtain LEED credits · Meet ASHRAE 15 standards · Low power consumption and `sleep mode' feature · Optimize HVAC use and extend life of components Applications · Auditoriums · Conference rooms · Schools · Hospitals · Washrooms · Kitchens · Janitorial closets · Copier/printing rooms · Warehouses/shipping areas Certifications · Intertek Listed to 3rd Editions of: UL 61010-1; and CSA C22.2 No. 61010-1-12 · Intertek tested to EN 61010:2010, EN 61000-63:2007 + A1:2011, and EN 50270:2006, Type 2 Equipment for Immunity; and DLS tested to EN 50270:2006 for CE Mark · BTL (BACnet) · LonWorks PG1100-9-NCL When placing an order, please reference the Order Number (not the Model Number) where applicable. 5 IAQPoint2 Indoor Air Quality Monitor (continued) IAQPoint2 Wall Mount Configurations IAQPoint2 with Analog Output Carbon dioxide (CO2) monitor, wall mount, analog Carbon dioxide (CO2) monitor, wall mount, analog, relay Carbon dioxide (CO2) monitor, wall mount, analog, temp and rH Carbon dioxide (CO2) monitor, wall mount, analog, temp and rH, relay Carbon dioxide (CO2) monitor, wall mount, analog, display Carbon dioxide (CO2) monitor, wall mount, analog, relay, display Carbon dioxide (CO2) monitor, wall mount, analog, temp and rH, display Carbon dioxide (CO2) monitor, wall mount, analog, temp and rH, relay, display VOC monitor, wall mount, analog VOC monitor, wall mount, analog, relay VOC monitor, wall mount, analog, temp and rH VOC monitor, wall mount, analog, temp and rH, relay VOC monitor, wall mount, analog, display VOC monitor, wall mount, analog, relay, display VOC monitor, wall mount, analog, temp and rH, display VOC monitor, wall mount, analog, temp and rH, relay, display Model Number IAQ-WAC IAQ-WAC-R IAQ-WAC-TRH IAQ-WAC-TRH-R IAQ-WAC-D IAQ-WAC-R-D IAQ-WAC-TRH-D IAQ-WAC-TRH-R-D IAQ-WAV IAQ-WAV-R IAQ-WAV-TRH IAQ-WAV-TRH-R IAQ-WAV-D IAQ-WAV-R-D IAQ-WAV-TRH-D IAQ-WAV-TRH-R-D IAQPoint2 with Digital Output, BACnet and Modbus (Selectable) Model Number Carbon dioxide (CO2) monitor, wall mount, network, display IAQ-WNC-D Carbon dioxide (CO2) monitor, wall mount, network, relay, display IAQ-WNC-R-D Carbon dioxide (CO2) monitor, wall mount, network, temp and rH, display IAQ-WNC-TRH-D Carbon dioxide (CO2) monitor, wall mount, network, temp and rH, relay, display IAQ-WNC-TRH-R-D VOC monitor, wall mount, network, display IAQ-WNV-D VOC monitor, wall mount, network, relay, display IAQ-WNV-R-D VOC monitor, wall mount, network, temp and rH, display IAQ-WNV-TRH-D VOC monitor, wall mount, network, temp and rH, relay, display IAQ-WNV-TRH-R-D IAQPoint2 with LonWorks Carbon dioxide (CO2) monitor, wall mount, LonWorks, display Carbon dioxide (CO2) monitor, wall mount, LonWorks, relay, display Carbon dioxide (CO2) monitor, wall mount, LonWorks, temp and rH, display Carbon dioxide (CO2) monitor, wall mount, LonWorks, temp and rH, relay, display VOC monitor, wall mount, LonWorks, display VOC monitor, wall mount, LonWorks, relay, display VOC monitor, wall mount, LonWorks, temp and rH, display VOC monitor, wall mount, LonWorks, temp and rH, relay, display Model Number IAQ-WLC-D IAQ-WLC-R-D IAQ-WLC-TRH-D IAQ-WLC-TRH-R-D IAQ-WLV-D IAQ-WLV-R-D IAQ-WLV-TRH-D IAQ-WLV-TRH-R-D Order Number 1508A1001 1508A1003 1508A1005 1508A1007 1508A1009 1508A1011 1508A1013 1508A1015 1508A1002 1508A1004 1508A1006 1508A1008 1508A1010 1508A1012 1508A1014 1508A1016 Order Number 1508A1017 1508A1019 1508A1021 1508A1023 1508A1018 1508A1020 1508A1022 1508A1024 Order Number 1508A1025 1508A1027 1508A1029 1508A1031 1508A1026 1508A1028 1508A1030 1508A1032 6 When placing an order, please reference the Order Number (not the Model Number) where applicable. PG1100-9-NCL IAQPoint2 Indoor Air Quality Monitor (continued) IAQPoint2 Duct Mount Configurations IAQPoint2 with Analog Output Carbon dioxide (CO2) monitor, duct mount, analog Carbon dioxide (CO2) monitor, duct mount, analog, relay Carbon dioxide (CO2) monitor, duct mount, analog, temp and rH Carbon dioxide (CO2) monitor, duct mount, analog, temp and rH, relay Carbon dioxide (CO2) monitor, duct mount, analog, display Carbon dioxide (CO2) monitor, duct mount, analog, relay, display Carbon dioxide (CO2) monitor, duct mount, analog, temp and rH, display Carbon dioxide (CO2) monitor, duct mount, analog, temp and rH, relay, display VOC monitor, duct mount, analog VOC monitor, duct mount, analog, relay VOC monitor, duct mount, analog, temp and rH VOC monitor, duct mount, analog, temp and rH, relay VOC monitor, duct mount, analog, display VOC monitor, duct mount, analog, relay, display VOC monitor, duct mount, analog, temp and rH, display VOC monitor, duct mount, analog, temp and rH, relay, display Model Number IAQ-DAC IAQ-DAC-R IAQ-DAC-TRH IAQ-DAC-TRH-R IAQ-DAC-D IAQ-DAC-R-D IAQ-DAC-TRH-D IAQ-DAC-TRH-R-D IAQ-DAV IAQ-DAV-R IAQ-DAV-TRH IAQ-DAV-TRH-R IAQ-DAV-D IAQ-DAV-R-D IAQ-DAV-TRH-D IAQ-DAV-TRH-R-D IAQPoint2 with Digital Output, BACnet and Modbus (Selectable) Carbon dioxide (CO2) monitor, duct mount, network, display Carbon dioxide (CO2) monitor, duct mount, network, relay, display Carbon dioxide (CO2) monitor, duct mount, network, temp and rH, display Carbon dioxide (CO2) monitor, duct mount, network, temp and rH, relay, display VOC monitor, duct mount, network, display VOC monitor, duct mount, network, relay, display VOC monitor, duct mount, network, temp and rH, display VOC monitor, duct mount, network, temp and rH, relay, display Model Number IAQ-DNC-D IAQ-DNC-R-D IAQ-DNC-TRH-D IAQ-DNC-TRH-R-D IAQ-DNV-D IAQ-DNV-R-D IAQ-DNV-TRH-D IAQ-DNV-TRH-R-D IAQPoint2 with LonWorks Carbon dioxide (CO2) monitor, duct mount, LonWorks, display Carbon dioxide (CO2) monitor, duct mount, LonWorks, relay, display Carbon dioxide (CO2) monitor, duct mount, LonWorks, temp and rH, display Carbon dioxide (CO2) monitor, duct mount, LonWorks, temp and rH, relay, display VOC monitor, duct mount, LonWorks, display VOC monitor, duct mount, LonWorks, relay, display VOC monitor, duct mount, LonWorks, temp and rH, display VOC monitor, duct mount, LonWorks, temp and rH, relay, display Model Number IAQ-DLC-D IAQ-DLC-R-D IAQ-DLC-TRH-D IAQ-DLC-TRH-R-D IAQ-DLV-D IAQ-DLV-R-D IAQ-DLV-TRH-D IAQ-DLV-TRH-R-D Order Number 1508A2001 1508A2003 1508A2005 1508A2007 1508A2009 1508A2011 1508A2013 1508A2015 1508A2002 1508A2004 1508A2006 1508A2008 1508A2010 1508A2012 1508A2014 1508A2016 Order Number 1508A2017 1508A2019 1508A2021 1508A2023 1508A2018 1508A2020 1508A2022 1508A2024 Order Number 1508A2025 1508A2027 1508A2029 1508A2031 1508A2026 1508A2028 1508A2030 1508A2032 PG1100-9-NCL When placing an order, please reference the Order Number (not the Model Number) where applicable. 7 301EM-20 & 301IRFS Refrigerant, Toxic & Combustible Gas Controller and Networkable Sensors R11, R123, R125, R134a, R22, R404a, R407c, R410a, R4310, R507a, CO, Cl2, H2S, NO2, NH3, O2, SO2, COMB The 301EM-20 acts as a controller for up to 20 remote sensors and suits a variety of gas detection system solutions for Mechanical Rooms. Particularly configured to meet ASHRAE 15, B-52 and International Mechanical Code requirements, the 301EM-20 is commonly used to optimize gas detection in mechanical and chiller rooms. A full complement of sensors (including toxic, oxygen, combustible gases and a full line of refrigerant sensors), horns, strobes and remote panels provide added flexibility to suit a variety of gas detection system solutions. Note: Non-branded versions of this product are available upon request. User Friendly · Easy to read LCD display · Autodiagnostic capabilities Economical Solution · Cost-effective answer for installation in Mechanical Rooms locations Flexible Operation · Able to operate with up to 20 remote sensors at a time · Various types of sensors available to simultaneously detect a range of different Refrigerant, Toxic and Combustible gases · Robust and reliable RS-485 Modbus communication Output Adaptability · Three 24 Vdc alarm outputs and four 4-20 mA outputs Safety Measures · Four fully programmable relays · Three alarm levels with built-in visual indicators and audible alarm Beneficial Options · Convenient stand-alone or network operation Applications · Mechanical Rooms Certifications · Intertek Classified (301IRFS) Listed (301EM) to: UL 61010-1; and CSA C22.2 No. 61010-1-04 8 When placing an order, please reference the Order Number (not the Model Number) where applicable. PG1100-9-NCL 301EM-20 & 301IRFS Refrigerant, Toxic & Combustible Gas Controller and Networkable Sensors 301EM Controllers Controller, Type 1 Canada (for use with R123) Controller, Type 2 Canada (for use with all other refrigerants) Controller, Type 3 US Controller with horn and strobe, Type 1 Canada Controller with horn and strobe, Type 2 Canada Controller with horn and strobe, Type 3 US Order Number 301-EM-CA1 301-EM-CA2 301-EM-US3 301-EM-RFSA-CA1 301-EM-RFSA-CA2 301-EM-RFSA-US3 Annunciator Panel for use with 301EM-20 Remote panel Remote panel with horn and strobe Order Number 301-EMRP 301-EMRP-RFSA S301IRF Sensors for use with 301EM-20 (0-1000 ppm) R11 refrigerant gas sensor R123 refrigerant gas sensor R125 refrigerant gas sensor R134a refrigerant gas sensor R22 refrigerant gas sensor R404a refrigerant gas sensor R407c refrigerant gas sensor R410a refrigerant gas sensor R4310 refrigerant gas sensor R507a refrigerant gas sensor Note: S301IRF sensors operate on 12 Vdc power only. Higher voltage will result in damage to the sensor. Order Number S301-IRF-R11 S301-IRF-R123 S301-IRF-R125 S301-IRF-R134A S301-IRF-R22 S301-IRF-R404A S301-IRF-R407C S301-IRF-R410A S301-IRF-R4310 S301-IRF-R507A S301D2 Sensors for use with 301EM-20 Combustible explosion proof sensor - (GAIN 1.0-1.3 / Methane) Combustible explosion proof sensor - (GAIN 1.3-1.599 / Hydrogen) Combustible explosion proof sensor - (GAIN 1.6-1.999 / Propane, Ethanol) Combustible explosion proof sensor - (GAIN 2.0-2.219 / n-Pentane) Combustible explosion proof sensor - (GAIN 2.220-2.5 / Toluene) Combustible explosion proof sensor - (GAIN +2.5 / n-Decane) Carbon monoxide (CO) explosion proof sensor Chlorine (Cl2) explosion proof sensor Nitrogen dioxide (NO2) explosion proof sensor Hydrogen sulfide (H2S) explosion proof sensor Oxygen (O2) explosion proof sensor Sulfur dioxide (SO2) explosion proof sensor Model Number S301D2COMB S301D2COMB S301D2COMB S301D2COMB S301D2COMB S301D2COMB S301D2CO S301D2CL2 S301D2NO2 S301D2H2S S301D2O2 S301D2SO2 Order Number 129570-L3 129426-L3 129427-L3 129428-L3 129429-L3 129430-L3 129431-L3 129435-L3 129432-L3 129433-L3 129436-L3 129434-L3 PG1100-9-NCL When placing an order, please reference the Order Number (not the Model Number) where applicable. 9 301EM-20 & 301IRFS (continued) EC-FX-EM Sensors for ammonia (NH3) detection for use with 301EM-20 Ammonia (NH3) Monitor, 4-20mA, Vulbus, 0-100 ppm, NEMA 1 Encl. Ammonia (NH3) Monitor, 4-20mA, Vulbus 0-250 ppm, NEMA 1 Encl. Ammonia (NH3) monitor, 4-20 mA, Modbus 0-500 ppm, NEMA 1 encl. Model Number ECFX-100-N-EM ECFX-250-N-EM EC-F9-NH3-0/500-N1-EM Order Number ECFX-100-N-EM ECFX-250-N-EM M-511010 EC-FX Replacements Cells Replacement ammonia (NH3) cell, 0-100/250 ppm Note: Backwards compatible with EC-F2 & EC-F9 transmitters Model Number EC-FX-NH3-LR Order Number EC-FX-NH3-LR EC-F9 Replacements Cells Replacement ammonia (NH3) cell Replacement ammonia (NH3) high range cell Replacement ammonia (NH3) cell Model Number EC-F2-RC-NH3 EC-F2-RC-NH3 EC-F2-NH3-RC-EXP Order Number M-507975 M-600043 M-600045 Options for use with 301EM-20 Break glass manual switch option for 301EM 301EM-20 light stack assembly with red lens, horn (85-103 dB), voltage rating, 24VDC LED Light Module, 24V AC/DC, green, for use with M-700123 LED Light Module, 24V AC/DC, blue, for use with M-700123 LED Light Module, 24V AC/DC, clear, for use with M-700123 LED Light Module, 24V AC/DC, yellow, for use with M-700123 LED Light Module, 24V AC/DC, amber, for use with M-700123 Vertical Stack Light Mounting Base w/cap Vertical Stack Light Mounting Base Metal guard for 301IRFS sensors 2-Position selector switch - 120 Vac Push button NO/NC - 120 Vac Push button NO/NC locked - 120 Vac 12/24 Vdc Power Supply, UL/cUL Listed, 2.5A @ 24Vdc Model Number EMBG IRFSENSORGUARD SEL-2POS-120V BP-120V-NO-NC BP-120V-LOCKED HPV5DC8UL Order Number M-508617 M-700123 M-700327 M-700328 M-700329 M-700330 M-700331 M-700332 M-700333 M-505352 M-505913 M-505912 M-505911 HPV5DC8UL 10 When placing an order, please reference the Order Number (not the Model Number) where applicable. PG1100-9-NCL Self-Contained Breathing Apparatus (SCBA) Aluminum Cylinders Honeywell Analytics' Self-Contained Breathing Apparatus (SCBA) meets the demands of industrial users who want the finest respiratory protection against environments that are Immediately Dangerous to Life or Health (IDLH). The SCBA is designed to be a basic industrial unit, yet provides superior safety and comfort for industrial needs. The SCBA is available in medium face piece/bell alarm or hooded with medium nose cup/plain whistle alarm configurations. Note: All cylinders are shipped fully charged. Breathing Apparatus SCBA, with low pressure 30 min. cylinder, medium facepiece, bell alarm SCBA, with low pressure 30 min. cylinder, hood with medium nose cup, plain whistle alarm SCBA, with high pressure 60 min. cylinder, medium facepiece, bell alarm Breathing Apparatus Accessories Spare 30 min. cylinder, low pressure Spare 60 min. cylinder, high pressure Video, use/maintenance SCBA CD-ROM, use/maintenance SCBA Storage case for 1 SCBA wall unit Aluminum truck mounting bracket for SCBA Order Number 888888 777777 555555 Order Number 915140 917160 995613 995612 83219 M-512890 PG1100-9-NCL When placing an order, please reference the Order Number (not the Model Number) where applicable. 11 SQN8x Sample Draw Refrigerant, Toxic & Combustible Sample-Draw Gas Monitoring System CO, COMB, NO2, O2, R11, R123, R125, R134A, R22, R227, R404A, R410A, R4310, R507 The new generation of the SQN8x series combines long proven sensing capability with state-of-the-art pumping technology and constant, high accuracy to yield a highly reliable sample draw gas detection system. Save costs through sensing capability to monitor gases in up to 8 different zones. Note: Each configuration includes one sensor and tubing as indicated. Safety Measures · 3 alarm relays · Audible alarm · Early low level warning alarm · Integrated flow loss surveillance Reliable · Wide area of coverage · 2, 4 or 8 sample points · Proven sensing technology · Up to 2 gases Applications · Chillers · Mechanical Rooms · Breweries · Wineries · Supermarkets Certifications · Intertek Classified to: UL 61010-1; and CSA C22.2 No. 61010-1-04 12 When placing an order, please reference the Order Number (not the Model Number) where applicable. PG1100-9-NCL SQN8x Sample Draw Refrigerant, Toxic & Combustible Sample-Draw Gas Monitoring System Gas 1 (required) Refrigerant (R11) Refrigerant (R123) Refrigerant (R12) Refrigerant (R134A) Refrigerant (R22) Refrigerant (R404A) Refrigerant (407c) Refrigerant (R410A) Refrigerant (R4310) Refrigerant (R507A) Combustibles (% LEL) Carbon monoxide (CO) Nitrogen dioixide (NO2) Oxygen (O2) Number of Sampling Points Two-point sample draw system (incl. 200ft tubing) Four-point sample draw system (incl. 400 ft tubing) Eight-point sample draw system (incl. 800 ft tubing) SQN8x Base Unit Base unit SQ8 Gas 2 (optional) R11 [ BLANK ] None R123 R11 Refrigerant (R11) R125 R123 Refrigerant (R123) R134A R125 Refrigerant (R12) R22 R134A Refrigerant (R134A) R404A R22 Refrigerant (R22) R407c R404A Refrigerant (R404A) R410A R407c Refrigerant (407c) R4310 R410A Refrigerant (R410A) R507A R4310 Refrigerant (R4310) CMB R507A Refrigerant (R507A) CO CMB Combustibles (% LEL) NO2 CO Carbon monoxide (CO) O2 NO2 Nitrogen dioixide (NO2) O2 Oxygen (O2) 2 Product Branding (optional) [ BLANK ] With logo 4 N No logo 8 Order number: SQ8 - - - (optional) Example 1: A SQN8x configured with a four-point sample draw system and a single gas detector (R134A) with product branding would be SQ84R134A. Example 2: A SQN8x configured with an eight-point sample draw system and dual gas detectors (R404A and CO) with no product branding would be SQ88R404ACON. SQN8x Spare Sampling Tube 200 ft. sampling tube (0.17 in. I.D., 0.25 in. O.D.) 400 ft. sampling tube (0.17 in. I.D., 0.25 in. O.D.) 800 ft. sampling tube (0.17 in. I.D., 0.25 in. O.D.) SQN8x Accessories Vacuum filter, 50 micron Sampling point with filter Model Number 8XTL5 8XTL9 8XTL14 Order Number 0235-0295 0235-0296 0235-0297 Order Number M-510806 M-504183 PG1100-9-NCL When placing an order, please reference the Order Number (not the Model Number) where applicable. 13 AirScanTM IR-F9 Standalone Refrigerant Gas Monitor for Cold Storage R134a, R22, R404a, R407a, R410a, R422d, R507a, HFO1234yf, CO2 The AirScanTM iR Sensor responds to refrigerants over the range of 0-1,000 ppm and features SensorCheckTM technology that continually monitors sensor performance. The AirScanTM iR Sensor is an affordable microprocessor-based sensor that is selective to refrigerants and, because of its stabilised design platform, will provide years of service and will maintain the highest level of accuracy and reliability. This highly versatile sensor features SensorCheckTM, a unique technology that continuously monitors sensor performance that enables it to provide worry-free performance throughout the life of the sensor. A true "diffusion" design sensor, the AirScanTM iR Sensor does not require either pumps or filters and allows all points of detection to be monitored perpetually, unlike sample draw systems. The versatile sensor is housed in a high mass metal bench structure that enables thermal stability and freedom from vibration. IR-F9 units configured to a full scale of 0-500 ppm are designed to meet California Air Review Board (CARB) requirements. Applications · Chiller Rooms · Food Processing · Cold Storage · Supermarkets AirScanTM IR-F9 with Commercial Enclosure Carbon dioxide (CO2) 0/10,000 ppm, commercial enclosure Carbon dioxide (CO2) 0/30,000 ppm, commercial enclosure HFO1234yf 0/500 ppm, commercial enclosure, CARBcompliant HFO1234yf 0/1000 ppm, commercial enclosure HFO1234yf 0/3000 ppm, commercial enclosure R22 0-500 ppm, commercial enclosure, CARBcompliant R22 0-1,000 ppm, commercial enclosure R134a 0-1,000 ppm, commercial enclosure R404a 0-1,000 ppm, commercial enclosure R407a 0-500 ppm, commercial enclosure, CARBcompliant R407a 0-1,000 ppm, commercial enclosure R410a 0-1,000 ppm, commercial enclosure R422d 0-500 ppm, commercial enclosure, CARBcompliant R422d 0-1,000 ppm, commercial enclosure R507a 0-1,000 ppm, commercial enclosure Model Number Order Number IR-F9-CO2-1%-COM M-700197 IR-F9-CO2-3%-COM M-700198 IR-F9-HFO1234yf-0/1000-COM M-700265 IR-F9-HFO1234yf-0/1000-COM M-700270 IR-F9-HFO1234yf-0/1000-COM M-700275 IR-F9-R22-0-500-COM M-700127 IR-F9-R22-0/1000-COM M-700137 IR-F9-R134a-0/1000-COM M-700138 IR-F9-R404a-0/1000-COM M-700139 IR-F9-R407a-0-500-COM M-700051 IR-F9-R407a-0/1000-COM M-700061 IR-F9-R410a-0/1000-COM M-700081 IR-F9-R422d-0-500-COM M-700022 IR-F9-R422d-0/1000-COM M-700031 IR-F9-R507a-0/1000-COM M-700140 AirScanTM IR-F9 Accessories Order Number 420MDBS-96D AirAlert 96d interface module 4-20 to RS485 with phoenix connector M-511352* Relay plug 4-20 signal term 3A 24 Vdc M-600008 *Note: MDBS modules require factory-set configuration parameters. Please specify at time of ordering. Use of this module inside a sensor will invalidate any certifications. 14 When placing an order, please reference the Order Number (not the Model Number) where applicable. PG1100-9-NCL Sensepoint® XCD Flammable, Toxic & Oxygen Gas Detector and Transmitter CH4, C3H8, C5H12, CO, CO2, H2, H2S, LEL, NO2, O2 The Sensepoint XCD range provides comprehensive monitoring of flammable, toxic and oxygen gas hazards in potentially explosive atmospheres, both indoors and outdoors. Users can modify detector operation using the LCD and magnet switches without ever needing to open the unit. This enables one-man, non-intrusive operation and reduces routine maintenance time and costs. One-Stop Shop · Flammable (catalytic or infrared), toxic and oxygen versions available · New and retrofit applications · Suitable for indoor or outdoor use · Aluminium explosion-proof housing · IP66 as standard Proven and Reliable Sensor Technology · SurecellTM electrochemical sensors · Reflex® sensor health check · Poison immune infrared sensors · Poison resistant catalytic bead sensors · Long life sensors Easy to Use · User friendly and intuitive tricolour backlit display with digits, bar graph and icons · Fully configurable via magnetic switches · Selectable sink or source 4-20 mA output · Auto-inhibit during maintenance · Modbus communications for remote diagnostics/configuration Cost Effective · Common transmitter platform · Minimal training required · Reduced spares · Non-intrusive, one-man operation · Plug-in sensor replacement · Modbus multi drop option offers cabling savings Simple Installation · Plug-in display module removes to give access to terminal area · Integral mounting bracket · 2 x ¾ in. NPT cable/conduit entries · Removable plug/socket type terminal blocks for ease of wiring · Sink/source switch to suit preferred wiring topology Range of Optional Accessories · Remote sensor gassing kit · Duct mounting kit · Calibration gas flow housing · Collecting cone Applications · Boiler Rooms · Hospitals · Warehouses · Chemical storage Certifications · US and Canadian · For additional information on certifications and approvals contact Honeywell Analytics PG1100-9-NCL When placing an order, please reference the Order Number (not the Model Number) where applicable. 15 Sensepoint® XCD (continued) Sensepoint XCD Transmitters Class I, Div. 1: UL & cUL Approvals Order Number Carbon monoxide (CO) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-250 ppm SPXCDULNCXM aluminum enclosure Combustible (CH4) explosion proof transmitter (Cat Bead), 4-20 mA, 3 relays, Modbus, 0-100% SPXCDULNFXM aluminum enclosure Combustible (C3H8) explosion proof transmitter (Cat Bead), 4-20 mA, 3 relays, Modbus, 0-100% SVIP3729 aluminum enclosure Custom calibration: SPXCDULNFXM PROPANE Combustible (H2) explosion proof transmitter (Cat Bead), 4-20 mA, 3 relays, Modbus, 0-100% aluminum enclosure Custom calibration: SPXCDULNFXM HYDROGEN SVIP3730 Combustible (C5H12) explosion proof transmitter (Cat Bead), 4-20 mA, 3 relays, Modbus, 0-100% aluminum enclosure Custom calibration: SPXCDULNFXM PENTANE SVIP3731 Hydrogen sulfide (H2S) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-50 ppm SPXCDULNHXM aluminum enclosure Nitrogen dioxide (NO2) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-50 ppm SPXCDULNNXM aluminum enclosure Oxygen (O2) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-25% aluminum enclosure SPXCDULNO1M Hydrogen (H2) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-1,000 ppm aluminum enclosure SPXCDULNG1M Sensepoint XCD Transmitters Class I, Div. 1: UL Approval Combustible explosion proof transmitter (IR), methane (CH4) 4-20 mA, 3 relays, Modbus, 0-100% LEL aluminum enclosure Combustible explosion proof transmitter (IR), propane (C3H8) 4-20 mA, 3 relays, Modbus, 0-100% LEL aluminum enclosure Carbon dioxide (CO2) explosion proof transmitter (IR), 4-20 mA, 3 relays, Modbus, 0-2% Vol aluminum enclosure EC: Electrochemical Cell / Cat Bead: Catalytic Bead / IR: Infrared Order Number SPXCDULNRXM SPXCDULNPXM SPXCDULNB1M 16 When placing an order, please reference the Order Number (not the Model Number) where applicable. PG1100-9-NCL Sensepoint® XCD (continued) XCD Consumables Class I, Div. 1 Flammable CAT 0-100% LEL (20 to 100.0% LEL) Oxygen (O2) 25.0%/Vol only Hydrogen sulfide (H2S) 0-50 ppm (10.0 to 100.0 ppm) Carbon monoxide (CO) 0-500 ppm (100 to 1000 ppm) Carbon dioxide (CO2) 0-2% VOL Hydrogen (H2) 0-1000 ppm only Nitrogen dioxide (NO2) 10-50 ppm Flammable IR 0-100% LEL methane (20 to 100.0% LEL) Flammable IR 0-100% LEL propane (C3H8) (20.0 to 100.0% LEL, 10% LEL) XCD Spares, Class I, Div. 1 Sensepoint XCD standard weather protection Sensor retainer with locking screw Allen key for stopper Hex wrench for earth screw Earth bracket and screws Magnetic wand XCD Accessories, Class I, Div. 1 Calibration cap Collecting cone for use with lighter than air gases Duct mounting kit Mounting bracket (inc. bolts, nuts, brackets) Sunshade / deluge protection Sensepoint XCD combustible calibration kit Sensepoint XCD toxic calibration kit Order Number SPXCDXSFXSS SPXCDXSO1SS SPXCDXSHXSS SPXCDXSCXSS SPXCDXSB1SS SPXCDXSG1SS SPXCDXSNXSS SPXCDXSRXSS SPXCDXSPXSS Order Number SPXDCWP SPXCDSRLS SPXCDAKS SPXCDHWES SPXCDEBS SPXCDMAG Order Number S3KCAL SPXCDCC SPXCDDMK SPXCDMTBR SPXCDSDP XCDCOMBKIT XCDTOXKIT PG1100-9-NCL When placing an order, please reference the Order Number (not the Model Number) where applicable. 17 Sensepoint® XCD RTD Remote Toxic & Oxygen Gas Detector and Transmitter Cl2, CO, H2, H2S, NH3, NO, NO2, O2, SO2 Sensepoint XCD RTD from Honeywell Analytics makes it easy on your maintenance team, time and budget when faced with the challenge of monitoring toxic gases in Class I, Div. 2 areas. You can mount the unit up to 100 feet from the transmitter to obtain maximum gas detection coverage in areas not easily accessible or where the sensor would not be visible, as in high-or low-level concealed areas, or detection outside the room being monitored. XCD RTD offers unrivaled flexibility and performance via its easily recognizable display (traffic light pattern) to convey safety status, communication and mounting options, and onboard diagnostics. Reduce Cost of Ownership Over Life of the Product · Cut stocking and procurement costs with a common transmitter platform · Reduce maintenance time and expense with non-intrusive, one-man operation · Simplify maintenance with plugin, removable sensor · Reduce inspection and training time with tri-color `traffic light' display conveying safety status at a glance · Simplify set-up and configuration with non-intrusive magnetic switches Applications · Class I, Div 2 Areas Certifications · US and Canadian · For additional information on certifications and approvals contact Honeywell Analytics Gain Added Flexibility, Reliability and Performance · Extend gas sensing element up to 100 ft. (30 m) from transmitter; mount in the most difficult to access areas · Reduce likelihood of human error via on-board diagnostics and easy-to-read display · Protect against dust/water ingress with IP66/67 rated stainless steel or aluminum enclosure · Prevent false alarms with autoinhibit during maintenance · Select sink or source 4-20 mA output; integral or remote configuration · Full range of accessories and purchase options let you choose the remote monitoring system that's right for your application Sensor Fitted to Remote Junction Box Note: Conduit and fittings not included 18 When placing an order, please reference the Order Number (not the Model Number) where applicable. PG1100-9-NCL Sensepoint® XCD RTD Remote Toxic & Oxygen Gas Detector and Transmitter Sensepoint XCD RTD Transmitters Class I, Div. 2: UL & cUL Approvals Order Number Oxygen (O2) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-25% aluminum enclosure, Class I, Div. 2 SPXCDULNO2M Hydrogen sulfide (H2S) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-50 ppm SPXCDULNH2M aluminum enclosure, Class I, Div. 2 Carbon monoxide (CO) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-200 ppm SPXCDULNC2M aluminum enclosure, Class I, Div. 2 Hydrogen (H2) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-1,000 ppm aluminum enclosure, Class I, Div. 2 SPXCDULNG2M Nitrogen dioxide (NO2) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-10 ppm SPXCDULNN2M aluminum enclosure, Class I, Div. 2 Ammonia (NH3) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-50 ppm aluminum enclosure, Class I, Div. 2 SPXCDULNA2M Chlorine (Cl2) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-5 ppm aluminum enclosure, Class I, Div. 2 SPXCDULNL2M Sulfur dioxide (SO2) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-15 ppm aluminum enclosure, Class I, Div. 2 SPXCDULNS2M Nitric oxide (NO) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-100 ppm aluminum enclosure, Class I, Div. 2 SPXCDULND2M Sensepoint XCD RTD Transmitters Class I, Div. 2: UL & cUL Approvals with Remote Mount Hardware Order Number Oxygen (O2) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-25% aluminum enclosure, Class I, Div. 2 with remote mount hardware SPXCDULNO2RM Hydrogen sulfide (H2S) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-50 ppm SPXCDULNH2RM aluminum enclosure, Class I, Div. 2 with remote mount hardware Carbon monoxide (CO) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-200 ppm SPXCDULNC2RM aluminum enclosure, Class I, Div. 2 with remote mount hardware Hydrogen (H2) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-1,000 ppm aluminum enclosure, Class I, Div. 2 with remote mount hardware SPXCDULNG2RM Nitrogen dioxide (NO2) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-10 ppm SPXCDULNN2RM aluminum enclosure, Class I, Div. 2 with remote mount hardware Ammonia (NH3) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-50 ppm aluminum enclosure, Class I, Div. 2 with remote mount hardware SPXCDULNA2RM Chlorine (Cl2) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-5 ppm aluminum enclosure, Class I, Div. 2 with remote mount hardware SPXCDULNL2RM Sulfur dioxide (SO2) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-15 ppm aluminum enclosure, Class I, Div. 2 with remote mount hardware SPXCDULNS2RM Nitric oxide (NO) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-10 ppm aluminum enclosure, Class I, Div. 2 with remote mount hardware SPXCDULND2RM EC: Electrochemical Cell / Cat Bead: Catalytic Bead / IR: Infrared PG1100-9-NCL When placing an order, please reference the Order Number (not the Model Number) where applicable. 19 Sensepoint® XCD RTD (continued) XCD Sensors Class I, Div. 2 Oxygen (O2) 0-25%Vol sensor Hydrogen sulfide (H2S) 0-50 ppm sensor Carbon monoxide (CO) 0-200 ppm sensor Hydrogen (H2) 0-1,000 ppm sensor Nitrogen dioxide (NO2) 0-10 ppm sensor Ammonia (NH3) 0-50 ppm sensor Chlorine (Cl2) 0-5 ppm sensor Sulfur dioxide (SO2) 0-15 ppm sensor Nitric oxide (NO) 0-100 ppm sensor Order Number 2106B1830 2106B1801 2106B1806 2106B1817 2106B1822 2106B1813 2106B1810 2106B1820 2106B1818 XCD Replacement Cells Class I, Div. 2 Oxygen (O2) 0-25%Vol replacement cell kit Hydrogen sulfide (H2S) 0-50 ppm replacement cell kit Carbon monoxide (CO) 0-200 ppm Cell Kit Hydrogen (H2) 0-1,000 ppm replacement cell kit Nitrogen dioxide (NO2) 0-10 ppm replacement cell kit Ammonia (NH3) 0-50 ppm replacement cell kit Chlorine (Cl2) 0-5 ppm replacement cell kit Sulfur dioxide (SO2) 0-15 ppm replacement cell kit Nitric oxide (NO) 0-100 ppm replacement cell kit Order Number 2106B1545 2106B1549 2106B1548 2106B1597 2106B1599 2106B1596 2106B1547 2106B1546 2106B1594 XCD Spares and Accessories, Class I, Div. 2 Sensepoint XCD RTD transmitter, 4-20 mA, 3 relays, Modbus Sensepoint XCD RTD remote junction box, 3 terminal Series 2000 weather housing for use with toxic sensor Series 2000 flow housing assembly Series 2000 flow housing assembly plastic Toxic calibration kit with calibration cover, removal tool, potentiometer adjustment tool Note: Flow housing (02000-A-1645) is required and must be ordered separately. Order Number SPXCDULNTX4M 2430-0021 02000-A-1635 02000-A-1645 02000-A-3120 2106B2114 XCD RTD Calibration Kit Sensepoint XCD RTD calibration kit - includes calibration cover, potentiometer, adjustment tool, flow housing, regulator and tubing (2106B2114, 02000-A-1645, 998-100-012, 998-100-003, 998-100-004) Order Number XCDRTDKIT 20 When placing an order, please reference the Order Number (not the Model Number) where applicable. PG1100-9-NCL Sensepoint XCD RFD Transmitter Display 705 Sensor LEL (*1*8) The Sensepoint RFD is a remote flammable detection system for LEL monitoring applications. The XCD RFD combines the XCD transmitter with the 705 combustible sensor, and is certified for use in ClassI Div.1 rated areas. The XCD RFD offers one man, non-intrusive, operation and reduces routine maintenance time and costs. The XCD transmitter includes two programmable alarm/fault relays as well as an industry standard 4-20mA output. Calibration and relay operation of the transmitter may be adjusted via the transmitters' backlit LCD. Outputs are automatically inhibited during adjustment thereby reducing the risk of false alarm at the control panel during maintenance. Sensepoint RFD is supplied with all necessary accessories for easy installation. It can be mounted on a wall or 2 in. round support pole using the universal bracket provided. The detector is ideal for use with either conduit or steel wire armored cable and glands and includes both 3/4 in. NPT and M20 entries to the junction box. Sensepoint RFD offers easy installation and fast routine operation. Compatible with both standard and high temperature variants of the Sensepoint and 705 flammable sensors from Honeywell Analytics the overall flexibility of the product range is increased. Meets ClassI Div.1 UL performance standards. Note: Conduit and fittings not included Sensor Fitted to Remote Junction Box Note: Conduit and fittings not included Transmitter - cCSAus Certified for North America (ClassI, Div.1, Groups B, C & D) Transmitter with LM25, 3/4 in. NPT entry, Modbus, aluminum Order Number SPXCDULNRFDM Sensor 705 combustible sensor - aluminum - cat bead (SG16B) 0-100% LEL, UL / CSA approved 705 high temperature combustible sensor (150°C) 3/4 in. NPT threads, UL approved Order Number 00705-A-1733 00705-A-1735 Junction Box UL/CSA aluminum 3 wire junction box Order Number 2430-0021 Kits - cCSAus Certified for North America (ClassI, Div.1, Groups B, C & D) All kits include transmitter, sensor, and junction box. Transmitter with LM25, 3/4 in. NPT entry, Modbus, aluminum, 705 sensor, and 3 wire junction box Transmitter with LM25, 3/4 in. NPT entry, Modbus, aluminum, 705 High Temp sensor, and 3 wire junction box Order Number XCDRFDLM XCDRFDLMH PG1100-9-NCL When placing an order, please reference the Order Number (not the Model Number) where applicable. 21 Sensepoint XCD RFD (continued) Accessories Pipe mounting bracket (inc. fixings and hex wrench set) Sunshade / deluge protection Weather protection stainless steel for 705 HT Nylon weather protection for combustible sensor Weather protection housing Duct mount adaptor assembly (requires 1283-1084) Sensepoint adaptor interface kit (requires 1283-1047) Calibration gas flow adaptor (for use with 705 sensors) Collecting cone (for use with MPD, Sensepoint and 705 sensors) XCD RFD Calibration Kit Sensepoint XCD RFD calibration kit - includes tubing, flow adaptor, regulator and carrying case (998-100-004, 00780-A-0035, 998-100-012 (1.5LPM), 998-100-003) Order Number SPXCDMTBR SPXCDSDP 00780-A-0076 02000-A-1640 02000-A-1635 1283-1047 1283-1084 00780-A-0035 02000-A-1642 Order Number XCDRFDKIT 22 When placing an order, please reference the Order Number (not the Model Number) where applicable. PG1100-9-NCL ToxyPoint Two-Wire Transmitter CO The ToxyPoint two wire transmitter provides continuous monitoring for carbon monoxide in ambient air and is designed to reduce the overall cost of ownership with a lower initial investment, eliminating maintenance costs and minimising building electrical operating costs. 2-Year disposable sensor, no calibration required. ToxyPoint TwoWire Transmitter ToxyPoint: disposable 2wire 420 mA carbon monoxide (CO) transmitter Model Number TP1-M Order Number M-503340 PG1100-9-NCL When placing an order, please reference the Order Number (not the Model Number) where applicable. 23 Midas® Extractive Gas Detector AsH3, B2H6, BCl3, BF3, Br2, C4F6, C5F8, CH2F2, CH3F, CH4, Cl2, ClO2, CO, CO2, F2, GeH4, H2, H2Cl2Si, H2S, HBr, HCl, HCN, HF, NF3, NH3, NO, NO2, O2, O3, PH3, Si2H6, SiH4, SO2, WF6 Extractive Midas® transmitters (universal) operate with sensor cartridges, for use as a local gas detector. Sensor Cartridges must be ordered separately. Units are powered by 24 Vdc or via Power over Ethernet (PoE). Transmitters provides 0-22 mA analog and Modbus/TCP Ethernet as standard outputs. Integral relays for A1, A2 and fault are included, and may be configured normally open or normally closed, latching or nonlatching. Transmitters include (1) PG16 gland fitting for power in and relays out, 1/4 in. O.D.x 1/8 in. I.D. Sample Inlet tubing (10 ft. / 3m), 1/4 in. O.D x 3/16 in. I.D. Exhaust tubing (10 ft. / 3m), and a sample line tubing duct adapter (1283K1090). Note: Order a sensor cartridge separately for each transmitter. Applications · Hospitals · School Labs · Chemical Storage Areas Certifications · Intertek Classified to: UL 61010-1; and CSA C22.2 No. 61010-1-04 · Intertek tested to EN 61010 Extractive Transmitter for Universal Gas Detection Midas® Extractive Transmitter Order Number MIDAS-T-004 Pyrolyzer Module for NF3 Gas Detection (order separate transmitter unit) Pyrolyzer Midas® transmitters provide detection of NF3 specifically. Unit includes a snap on pyrolyzer module that operates with any Universal Midas® Extractive Transmitter (order separately) and (1) Freon in line filter. Units are powered via direct connection to transmitter unit. Order Number Midas® Pyrolyzer Module MIDAS-T-0P3 Note: Order the NF3 cartridge (MIDAS-S-HFX) and ventilated top cover (MIDAS-A-039) separately. High Temperature Pyrolyzer Module for Perfluoro Compounds (PFC) Gas Detection Higher Temperature Pyrolyzer Midas® transmitters provide detection of C4F6, C5F8 and other gases. Unit includes a snap on pyrolyzer module that operates with any Universal Midas® Extractive Transmitter (order separately). Units are powered via direct connection to transmitter unit. Pyrolyzer includes installation screws. Order Number Midas® High Temperature Pyrolyzer Module MIDAS-T-HTP Note: Order transmitter uint, PFC cartridge (MIDAS-S-CFX) and ventilated top cover (MIDAS-A-039) separately. LonWorks Module for Midas® Transmitter Connection Optional LonWorks interface module that mounts to and connects with any single, universal Midas® extractive transmitter with or without Pyrolyzer (order these separately) to provide bi-directional LonWorks connectivity; remote reset and remote control of the onboard relays. Unit is 24 Vdc powered and provides power and communications directly to the attached Midas® transmitter using special Ethernet cross over cable (supplied). Includes mounting bracket to the Midas® transmitter; rear panel installation screws are not supplied. Order Number Midas® LonWorks Interface Module MIDAS-T-LON Quad LonWorks Module for External Transmitter Connection Optional Modbus/TCP to LonWorks converter gateway that can connect up to 4 Midas® transmitters (with or without Pyrolyzers) to a LonWorks network. Requires separate 24 Vdc power supply and Ethernet connector cables. Suitable for DIN rail mounting. Consult Honeywell Analytics for full technical details. Access to LonMaker programming is required (not included). Order Number Midas® Quad LonWorks Module MIDAS-A-035 24 When placing an order, please reference the Order Number (not the Model Number) where applicable. PG1100-9-NCL Midas® Extractive Gas Detector Midas® Transmitter and Cartridge Combined Kits A complete kit including one universal Midas® transmitter unit (Midas-T-001) and one Midas® sensor cartridge can be ordered as a combined package. Each cartridge is supplied with an extended 2 year warranty. This is the recommended kit for a new installation of a complete gas detection circuit. Cartridge and Transmitter are packaged separately for ease of installation. The detectable range is listed (outside of deadband). With the exception of O2 (where ambient concentration is typically 20.9%), the sensors will display zero when no gas is present. Order Number Ammonia (NH3) Arsine (AsH3), germane (GeH4) Boron trichloride (BCl3), dichlorosilane (H2Cl2Si), hydrogen bromide (HBr), hydrogen chloride (HCl) Boron trifluoride (BF3), hydrogen fluoride (HF), nitrogen trifluoride (NF3) Note: Must order MIDAS-T-00P Pyro, tungsten hexafluoride (WF6) Boron trifluoride (BF3), low level, hydrogen fluoride (HF), low level (LDL = 0.22 ppm), tungsten hexafluoride (WF6), low level Bromine (Br2), chlorine dioxide (ClO2) Difluoromethane (CH2F2) Note: Contact your local RSM or Inside Sales for special ordering requirements. MIDAS-K-NH3 MIDAS-K-ASH MIDAS-K-HCL MIDAS-K-HFX MIDAS-K-HFL MIDAS-K-BR2 MIDAS-K-CFX Carbon dioxide (CO2) Carbon monoxide (CO) MIDAS-K-CO2 MIDAS-K-COX Chlorine (Cl2), fluorine (F2) Hydrogen (H2) Hydrogen cyanide (HCN) MIDAS-K-HAL MIDAS-K-H2X MIDAS-K-HCN Hydrogen sulfide (H2S) Hydrogen (H2), methane (CH4) Nitric oxide (NO) MIDAS-K-H2S MIDAS-K-LEL MIDAS-K-NOX Nitrogen dioxide (NO2) Oxygen (O2) Ozone (O3) Phosphine (PH3) Silane (SiH4) (low level) Silane (SiH4), disilane (Si2H6) Sulfur dioxide (SO2) TEOS MIDAS-K-NO2 MIDAS-K-O2X MIDAS-K-O3X MIDAS-K-PH3 MIDAS-K-SHL MIDAS-K-SHX MIDAS-K-SO2 MIDAS-K-TEO Note: To detect NF3, a separate pyrolyzer module (MIDAS-T-00P) must also be ordered. PG1100-9-NCL When placing an order, please reference the Order Number (not the Model Number) where applicable. 25 Midas® Extractive Gas Detector (continued) Mounting Accessories Midas® "L" bracket for vertical mounting Midas® DIN rail mounting kit Ventilated Midas® top cover for pyrolyzer applications Flexible conduit, 21 in. length Flexible conduit, 27 in. length 2A 24 Vdc power supply in vented NEMA4 enclosure 5A 24 Vdc power supply in vented NEMA4 enclosure Order Number MIDAS-A-032 MIDAS-A-036 MIDAS-A-039 0235-0128 0235-0163 MVIP3632-2A MVIP3632-5A Duct Sampling Adaptors Duct adapter for 1/4 in. O.D. tubing for 4-16 in. round ducts Union fitting 1/4 in. tube, polypropylene Order Number 1283K1090 0235-0095 Tubing and External Sample Line Filters Order Number End of line particulate filter, disposable 780248 End of line particulate filter for corrosive gases, this disposable filter provides protection against particulate build up in the sample line when monitoring for corrosive gases. 1991-0147 Union fitting - use to connect disposable filter to end of line 0235-0095 End of line particulate filter for corrosive gases, this reusable filter housing provides protection 1830-0055 against particulate build up in the sample line when monitoring for corrosive gases. Replaceable filter element (P/N 0235-1072) purchased separately Replacement "corrosive" filter elements (pack of 100), for use in 1830-0055 filter housing 0235-1072 Freon filter for NF3 pyrolyzing gas detector 1830-0027 Freon filter for NF3 pyrolyzing gas detector (extended life) Note: Not for use with C4F6, C5F8, CH3F, CH2F2 pyrolyzers Tubing Teflon® FEP 1/4 in. OD x 1/8 in. ID (sample inlet) (per ft.) 1830-0080 102599 Tubing Teflon® FEP 1/4 in. OD x 1/8 in. ID (sample Inlet) (100 ft. continuous length) 1991-0136 Tubing polypropylene 1/4 in. OD X 3/16 in. ID (exhaust) (per ft.) 100440 Tubing polypropylene 1/4 in. OD X 3/16 in. ID (exhaust) (100 ft. continuous length) 1991-0137 26 When placing an order, please reference the Order Number (not the Model Number) where applicable. PG1100-9-NCL Midas® Extractive Gas Detector (continued) Midas® Sensor Cartridges Cartridges are required for all of the above transmitters sensors at time of purchase and for replacement. Several Midas® cartridges can be configured via the transmitter to read a number of different gases based on a common chemical family. Actual details for the sensor detection range are included in the sensor cartridge data sheet and the Midas® technical manual. Midas® sensor cartridges can be ordered as part of a Kit with the universal Midas® transmitter, or as a replacement part with either standard or extended warranty cover. The detectable range is listed (outside of deadband). With the exception of O2 (where ambient concentration is typically 20.9%), the sensors will display zero when no gas is present. Order Number Ammonia (NH3) Arsine (AsH3), germane (GeH4) MIDAS-E-NH3 MIDAS-E-ASH Boron trichloride (BCl3), dichlorosilane (H2Cl2Si), hydrogen bromide (HBr), hydrogen chloride (HCl) MIDAS-E-HCL Boron trifluoride (BF3), hydrogen fluoride (HF), nitrogen trifluoride (NF3), tungsten hexafluoride (WF6) MIDAS-E-HFX Boron trifluoride (BF3), low level, hydrogen fluoride (HF), low level (LDL = 0.22 ppm), tungsten hexafluoride (WF6), low level MIDAS-E-HFL Bromine (Br2), chlorine dioxide (ClO2) MIDAS-E-BR2 Difluoromethane (CH2F2), hexafluorobutadiene (C4F6), methyl fluoride (CH3F), octofluorocyclopentene MIDAS-E-CFX (C5F8), sulfur hexafluoride (SF6) Carbon dioxide (CO2) Carbon monoxide (CO) MIDAS-E-CO2 MIDAS-E-COX Chlorine (Cl2), fluorine (F2) MIDAS-E-HAL Diborane (B2H6) MIDAS-E-B2H Hydrogen (H2) MIDAS-E-H2X Hydrogen cyanide (HCN) MIDAS-E-HCN Hydrogen sulfide (H2S) MIDAS-E-H2S Hydrogen (H2), methane (CH4) Nitric oxide (NO) MIDAS-E-LEL MIDAS-E-NOX Nitrogen dioxide (NO2) Oxygen (O2) MIDAS-E-NO2 MIDAS-E-O2X Ozone (O3) Ozone (O3) (high level) MIDAS-E-O3X MIDAS-E-O3H Phosphine (PH3) Silane (SiH4) (low level) MIDAS-E-PH3 MIDAS-E-SHL Silane (SiH4), disilane (Si2H6) MIDAS-E-SHX Sulfur dioxide (SO2) MIDAS-E-SO2 TEOS MIDAS-E-TEO Calibration Kit Midas® calibration kit Order Number MIDASCALKIT PG1100-9-NCL When placing an order, please reference the Order Number (not the Model Number) where applicable. 27 Commercial Accessories Strobe-Horn DC strobe and horn (P4W-P) Strobe and horn RED lens - 120 Vac - indoor application Strobe and horn BLUE lens - 120 Vac - indoor application Strobe and horn AMBER lens - 120 Vac - indoor application 2-wire horn strobe, standard candela, white, wall, 12 or 24 Vdc 2-wire horn strobe, high candela, white, wall, 12 or 24 Vdc 2-wire outdoor horn strobe, standard candela, white, wall, 12 or 24 Vdc 2-wire outdoor horn strobe, high candela, white, wall, 12 or 24 Vdc 2-wire horn strobe, standard candela, white, ceiling, 12 or 24 Vdc 2-wire horn strobe, high candela, white, ceiling, 12 or 24 Vdc Strobe and horn, RED lens, 24 Vac, indoor or outdoor Strobe and horn, BLUE lens, 24 Vac, indoor or outdoor Strobe and horn, AMBER lens, 24 Vac, indoor or outdoor Stackable base with horn - 120 Vac - indoor or outdoor Stackable strobe - RED Lens - 120 Vac - indoor or outdoor Stackable strobe - BLUE Lens - 120 Vac - indoor or outdoor Stackable strobe - AMBER Lens - 120 Vac - indoor or outdoor MT4 multitone strobe Model Number FHS-240 STASR STASB STASA P2W-P P2WH-P P2WK-P P2WHK-P PC2W-P PC2WH-P STASR24VAC STASB24VAC STASA24VAC STACKSTASBASE STACKSTASR STACKSTASB STACKSTASA WHEELOCK Strobe Strobe RED lens - 120 Vac - indoor or outdoor application Strobe BLUE lens - 120 Vac - indoor or outdoor application Strobe AMBER lens - 120 Vac - indoor or outdoor application Strobe (NEMA4X) RED - 120 Vac - Div. 2 hazardous loc Strobe (NEMA4X) BLUE - 120 Vac - Div. 2 hazardous loc Strobe (NEMA4X) AMBER - 120 Vac - Div. 2 hazardous loc Explosion Proof strobe - 120 Vac - Class I, Div. 2 - wall mount Strobe, standard candela, white, wall mount Strobe, standard candela, white, ceiling mount Strobe, high candela, white, wall mount Outdoor strobe, standard candela, white, wall mount Outdoor strobe, high candela, white, wall mount Speaker strobe, standard candela, white, wall mount Speaker strobe, high candela, white, wall mount Speaker strobe, standard candela, high dB, white, wall mount Outdoor speaker strobe, standard candela, white, wall mount Sync Module 3 (white) Sync Module 3 (red) Model Number STAS50R120V STAS50B120V STAS50A120V STASHAZR120V STASHAZB120V STASHAZA120V STASDEFMUR120 SW-P SCW-P SWH-P SWK-P SWHK-P SPSW-P SPSWH-P SPSWV-P SPSWK-P MDL3W MDL3R Order Number P4W-P M-503258 M-500902 M-503257 P2W-P P2WH-P P2WK-P P2WHK-P PC2W-P PC2WH-P M-506949 M-512023 M-512024 M-500877 M-501809 M-501807 M-501806 WH-126143 Order Number M-502831 M-500901 M-500710 M-502022 M-502021 M-502020 M-501763 SW-P SCW-P SWH-P SWK-P SWHK-P SPSW-P SPSWH-P SPSWV-P SPSWK-P MDL3W MDL3R 28 When placing an order, please reference the Order Number (not the Model Number) where applicable. PG1100-9-NCL Commercial Accessories Horn Horn - 120 Vac - indoor application Horn (NEMA4X) - 120 Vac - indoor or outdoor application Explosion proof horn - 120 Vac - Class I Div. 1 and 2, tone selectable Explosion proof horn - 120 Vac - Class I Div. 1 Model Number HORN120VAC HORNWith P120V HORNEXPL120VTS HORNEXPL120V Lens Wall mount lens attachment, blue Wall mount lens attachment, red Wall mount lens attachment, amber Wall mount lens attachment, green Model Number LENS-B LENS-R LENS-A LENS-G Power Supplies 120 Vac to 24 Vdc adapter for System Sensor horn and strobe units 24 Vac transformer, rate at 50 VA Model Number MP120K VA201TA50 Power Supplies: UL or UL/cUL Approved 12/24 Vdc power supply, UL/cUL listed, 2.5A @ 24 Vdc 24 Vdc power supply, 6.5A UL approved 24 Vac power supply, UL/cUL listed, 100 VA, 4.1A @ 24 Vac 24 Vac power supply, UL/cUL listed, 200 VA, 8.3 @ 24 Vac 24 Vac power supply, UL/cUL listed, 400 VA, 16.6A @ 24 Vac Model Number HPV5DC8UL PS-24-150-N12 HPTV2404UL HPV2401UL HPV2416-1UL Uninterruptable Power Supplies (UPS) UPS750VA 120V APC Smart-UPS 750 VA UPS1000VA 120V APC Smart-UPS 1000 VA UPSAPCBP, battery unit for APC Smart-UPS Order Number M-507960 M-508370 SMX48RMBP2U Order Number M-503973 M-503974 0130-0018 M-501767 Order Number LENS-B LENS-R LENS-A LENS-G Order Number MP120K M-503380 Order Number HPV5DC8UL M-600400 HPTV2404UL HPV2401UL HPV2416-1UL PG1100-9-NCL When placing an order, please reference the Order Number (not the Model Number) where applicable. 29 Calibration Equipment Gas Legend % LEL CBrF3 / R13B1 CCl3F / R11 CF3-CH2F / R134A CH2F2 / R32 CH3CHF2 / R125 CH4 CHCl2CF3 / R123 CHClF2 / R22 Combustibles Cl2 Trifluorobromomethane ClO2 Trichloromonofluoromethane CO 1,1,1,2-Tetrafluoroethane CO2 Difluoromethane C3H8 Pentafluoroethane ETO Methane H2S Dichlorotrifluoroethane HCI Chlorodifluoromethane HCN Chlorine Chlorine dioxide Carbon monoxide Carbon dioxide Propane Ethylene oxide Hydrogen sulfide Hydrogen chloride Hydrogen cyanide N2 NH3 NO2 O2 O3 PH3 SO2 VOCs Nitrogen Ammonia Nitrogen dioxide Oxygen Ozone Phosphine Sulfur dioxide Volatile organic compounds Calibration Kits Cal kit for 58-103L cylinders (all products except SQN8x, AirScanTM IR-F9 and XCD) Sensepoint XCD combustilbe calibration kit Sensepoint XCD toxic calibration kit Sensepoint XCD RTD calibration kit - includes calibration cover, potentiometer, adjustment tool, flow housing, regulator and tubing (2106B2114, 02000-A-1645, 998-100-012, 998-100-003, 998-100-004) Sensepoint XCD RFD calibration kit - includes tubing, flow adaptor, regulator and carrying case (998-100-004, 00780-A-0035, 998-100-012 (1.5LPM), 998-100-003) AirScanTM IR-F9 calibration kit for use with 58/103L cylinders Demand flow regulator 58-103L cylinders, 0-3LPM for SQN8x Cal kit tubing 6 ft. 1/8 in. I.D. X 1/4 in. O.D. for SQN8x Bump test kit; includes balloon adapter and quad gas cylinder: H2S (40 ppm), CO (200 ppm), CH4 (2.5%), O2 (10%) Order Number 1309K0002 XCDCOMBKIT XCDTOXKIT XCDRTDKIT 705CALKIT 11337-L9 M-700144 M-501062 TEST-1A 58L Calibration Gas Cylinders NH3 (25 ppm) NH3 (50 ppm) NH3 (100 ppm) NH3 (500 ppm) H2S (25 ppm) NO2 (5 ppm) Cl2 (5 ppm) NO (100 ppm) SO2 (5 ppm) Balance N2 N2 Air Air N2 N2 N2 N2 N2 Liters Order Number 58 GFV213 58 2992-0015 58 M-501041 58 M-507546 58 M-501046 58 M-501054 58 M-501052 58 2992-0035 58 M-501055 103L Calibration Gas Cylinders Air N2 CH4 (1% / 20% LEL) (continued next page) Balance Air N2 Air Liters Order Number 103 M-501008 103 M-501011 103 M-500975 30 When placing an order, please reference the Order Number (not the Model Number) where applicable. PG1100-9-NCL Calibration Equipment 103L Calibration Gas Cylinders (cont'd) CH4 (25% LEL) CH4 (50% LEL) C3H8 (20% LEL) C3H8 (50% LEL) C2H4 (50% LEL) H2 (1% / 20% LEL) H2 (500 ppm) O2 (20%) O2 (20.9%) CO (200 ppm) CO2 (1,000 ppm) CO2 (2,000 ppm) CCl3F (R11) (500 ppm) CBrF3 (R13B1) (500 ppm) CHClF2 (R22) (500 ppm) CHCl2CF3 (R123) (500 ppm) CH3CHF2 (R125) (500 ppm) CF3-CH2F (R134A) (500 ppm) HFO-1234yf (500 ppm) HFO-1234yf (1000 ppm) HFO-1234yf (3000 ppm) R4310 (500 ppm) Blend of R125, R143A and R134A (R404A) (500 ppm) Blend of R32, R125 and R134A (R407C) (500 ppm) Blend of R32 and R125 (R410) (500 ppm) 50/50 Blend of R32 and R125 (R507) (500 ppm) Balance Air Air Air Air Air Air Air N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 Liters Order Number 103 998-012-001 103 998-022-001 103 M-507700 103 998-022-002 103 998-022-004 103 M-500976 103 1991-0159 103 M-500986 103 M-508161 103 M-500988 103 M-501010 103 M-500989 103 M-501012 103 M-511687 103 M-501005 103 M-501003 103 M-501004 103 M-504530 103 GFV543 103 GFV544 103 GFV545 103 0320-1024 103 M-509316 103 M-511688 103 M-511942 103 M-509317 103L Calibration Gas Cylinders: 100 ppm Refrigerant Calibration Gas; Designed for testing AirScanTM IR-F9, CARB 32 Units CHClF2 (R22) (100 ppm) CHCl2CF3 (R123) (100 ppm) CF3-CH2F (R134A) (100 ppm) Blend of R143A, R125 and R134A (R404A) (100 ppm) Blend of R32, R125 and R134A (R407C) (100 ppm) Blend of R32 and R125 (R410) (100 ppm) 50/50 Blend of R32 and R125 (R507) (100 ppm) Balance N2 N2 N2 N2 N2 N2 N2 Liters Order Number 103 GFV541 103 M-500981 103 GFV542 103 GFV540 103 GFV539 103 GFV537 103 GFV538 PG1100-9-NCL When placing an order, please reference the Order Number (not the Model Number) where applicable. 31 Honeywell Analytics Service Honeywell Analytics' global standing for portable, fixed and low level toxic gas detection is backed up with a dedicated team of professionals that takes service and support to a whole new level. It's your choice... Whatever industry you're in, we have the levels of support that are right for your business. It's your business. It's your industry. And no matter whether you're managing personnel for confined space entry, or securing your plant against gas risks, the process has to keep moving. The alternative is downtime, or even total shutdown, and then the risks to your business are far greater. Honeywell provides service levels that make it easy to choose the right kind of support to keep your plant and people safe; to keep your business up and running - because that's our job! Choose from: Commissioning · Functional tests · Start-up · Staff training · Bump testing Contract Maintenance Service and Repair · On-site/workshop repair and calibration · Modification and conversion Calibration and Surveys · Instrument calibration equipment certified to national/regional standards · Site surveys · Stock surveys Honeywell Analytics Service contact information: USA Service Workshop Headquarters 405 Barclay Blvd. Lincolnshire, IL 60069 USA Attn: Service Dept. Tel: 888-955-2585 (press 2) Fax: 847-572-1327 Email: haservice.workshop.us@honeywell.com Canada Service Workshop Headquarters 3580 Rue Isabelle Unit 100 Brossard, Quebec, Canada J4Y 2R3 Tel: 1-800-563-2967 (select language + press 2) Email: haservice.canada@honeywell.com 32 When placing an order, please reference the Order Number (not the Model Number) where applicable. PG1100-9-NCL Honeywell Analytics Lines of Business Commercial Gas detection from standalone units to fully engineered, multi-point systems, all offering cost-effective regulatory compliance » Applications: parking structures, chillers, mechanical rooms, office towers, commercial buildings, shopping centers, swimming pools, golf courses, schools and universities, laboratories Industrial Renowned Sieger and Manning gas detection systems with advanced electrochemical, infrared and open path sensing technologies » Applications: oil and gas, cold storage, water/wastewater treatment, chemicals, engine rooms, plastics and fibers, agriculture, printing and light industrial Portables Single or multi-gas and other premium detectors with compact, lightweight designs ranging from simple alarm only units to advanced, fully configurable and serviceable instruments » Applications: underground utility and electricity ducts, boiler rooms, post-fire sites, sewers, industrial plants, industrial hygiene, first responder teams, remote fleets Find out more www.honeywellanalytics.com USA Honeywell Analytics, Inc. 405 Barclay Blvd. Lincolnshire, IL 60069 USA Toll-free: 888-955-2585 (press 1) Tel: 847-955-8200 Fax: 847-955-8210 hasales.us@honeywell.com USA Technical Services Tel: 888-955-2585 (press 2) haservice.workshop.us@honeywell.com Canada 2840 2nd Ave SE Calgary, Alberta, Canada T2A 7X9 3580 Rue Isabelle Unit 100 Brossard, Quebec, Canada J4Y 2R3 High Tech/Government A complete portfolio of gas and chemical detection instrumentation including infrared spectroscopy (MST) with no cross interference, to Chemcassette paperbased solutions (MDA Scientific) offering detection down to parts per billion » Applications: semiconductor manufacturing and nanotechnology, aerospace propulsion and safety, specialty chemicals industry, research laboratories, emergency response Technical Services 24/7 global network includes post-sales service and Systems Integration teams » Emergency call out, service contracts, on/off-site repair, training and commissioning » Complete range of spares, consumables and accessories Toll-free: 1-800-563-2967 (select lang. + press 1) Tel: 847-955-8200 Fax: +1-450-619-2448 hasales.canada@honeywell.com Canada Technical Services Tel: 1-800-563-2967 (select lang. + press 2) haservice.canada@honeywell.com www.honeywell.com Latin & South America Marginal da Rodovia dos Bandeirantes, 100 Distrito Industrial Jundiaí, São Paulo Brazil ZIP: 13213-008 Tel: +55 11 3309 1030 Fax: +55 11 3309 1005 ha.latinamerica@honeywell.com Europe, Middle East, Africa Life Safety Distribution AG Javastrasse 2 8604 Hegnau Switzerland Tel: +41 (0) 44 943 4380 Fax: +41 (0) 44 943 4398 gasdetection@honeywell.com Asia Pacific Honeywell Analytics, Asia Pacific #701 Kolon Science Valley (1) 43 Digital-Ro 34-Gil, Guro-Gu Seoul 152-729 Korea Tel: +82 2 6909 0300 Fax:+82 2 6909 0329 analytics.ap@honeywell.com Please Note: While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract. PG1100-9-NCL © 2015 Honeywell AnalyticsAdobe PDF Library 11.0 Adobe InDesign CC 2014 (Windows)