Honeywell Analytics

Options for use with 301EM-20 Break glass manual switch option for 301EM 301EM-20 light stack assembly with red lens, horn (85-103 dB), voltage rating, 24VDC LED Light...

2015 Product Guide - Gas & Flame Detection | Honeywell

Oxygen, Toxic & Combustible Gas Controller. User Friendly. • Zero maintenance. • Automatic quick self-test and warm-up. • Continuous alphanumeric display.

2015 Product Guide - Gas Leak & Flame Detection | Honeywell

Carbon dioxide (CO2) monitor, duct mount, network, temp and rH, display. IAQ-DNC-TRH-D. 1508A2021. Carbon dioxide (CO2) monitor, duct mount, network, ...

PDF preview unavailable. Download the PDF instead.

2015CommercialProductGuidePG11009NCL
Honeywell Analytics

2015 Product Guide
Commercial Gas Detection

Contact Information

USA

405 Barclay Blvd. Lincolnshire, IL 60069 USA

Order Status, Pricing Information and Product Availability

Tel:

+1.888.955.2585 (press 1)

Order Placement or Making Changes to an Order

Email: hasales.us@honeywell.com

Fax:

+1.847.955.8210

Product Information and Application Questions

Tel:

+1.888.955.2585 (press 1)

Email: hasales.us@honeywell.com

Product Information, Application Support & Written Quotations Call or email your Regional Sales Managers

Technical Support

Tel:

+1.888.955.2585 (press 2)

Email: haservice.workshop.us@honeywell.com

Latin & South America

Marginal da Rodovia dos Bandeirantes, 100 - Distrito Industrial Jundiaí, São Paulo ­ Brazil ZIP: 13213-008

Tel: Fax: Email:

+55 11 3309 1030 +55 11 3309 1005 ha.latinamerica@honeywell.com

Canada

2840 2nd Ave SE Calgary, Alberta, Canada T2A 7X9

3580 Rue Isabelle Unit 100 Brossard, Quebec, Canada J4Y 2R3

Order Status, Pricing Information and Product Availability

Tel:

+1.800.563.2967 (select language + press 1)

Order Placement or Making Changes to an Order

Email: hasales.canada@honeywell.com

Fax:

+1.450.619.2448

Product Information and Application Questions

Tel:

+1.800.563.2967 (select Language + press 1)

Email: hasales.canada@honeywell.com

Product Information, Application Support & Written Quotations Call or email your Regional Sales Managers

Technical Support

Tel:

+1.800.563.2967 (select language + press 2)

Fax:

+1.450.619.2447

Email: haservice.canada@honeywell.com

2

When placing an order, please reference the Order Number (not the Model Number) where applicable.

PG1100-9-NCL

Table of Contents
E³Point .....................................................2 301C.........................................................4 IAQPoint2.................................................5 301EM-20 & 301IRFS..............................8 Self-Contained Breathing Apparatus
(SCBA)..............................................11 SQN8x Sample Draw.............................12 AirScanTM IR-F9.....................................14 Sensepoint® XCD...................................15 Sensepoint® XCD RTD...........................18 Sensepoint® XCD RFD...........................21 ToxyPoint...............................................23 Midas® Extractive Gas Detector............24 Commercial Accessories.......................28 Calibration Equipment...........................30 Service Information................................32

PG1100-9-NCL

Note Please note that specifications and exact product offering are subject to change without notice. Additonal shipping and handling fees may apply for some products. This publication is not intended to form the basis of a contract.

When placing an order, please reference the Order Number (not the Model Number) where applicable.

1

E³Point
Toxic & Combustible Gas Monitor
CO, NO2, H2S, H2, O2, CH4, C3H8
Sensor Cartridge Remote Sensor

Make your operation run more intelligently to protect people, property and your bottom line. Protect parking structures, loading docks, transport terminals, hospital/ambulance bays, car washes, battery charging rooms and hydrogen tanks, commercial kitchens, indoor stadiums, outbuildings and more.
Note: Non-branded versions of this product are available upon request.

Flexible Operation · Comes in standalone,
standalone with remote (dual gas mode) or network versions · Connects to analog or digital systems · Works with virtually any BAS including BACnet or Modbus · Wall or duct mount · Factorycalibrated cartridges
Cost Effective · Saves energy through Demand
Control Ventilation (DCV) · Simplifies installation/maintenance
through plugnplay sensor · Remote sensor option provides
dual gas monitoring (standalone version only) · Optimizes BAS, fire, ventilation and other security systems
Versatile Communications · Works through BAS to improve
fault diagnostics and collect data on gas concentation levels, sensor condition, etc. · Couple with 301C to log data and daisychain up to 96 E³Point units
Advanced Sensing Technology · Detects CO, NO2, O2, H2, H2S,
CH4, C3H8 · Advanced electrochemical (for
toxic gases) and catalytic bead (for combustible gases) sensor performance · Uses patented Reflex® and smart cartridge technologies

Range of Accessories · Factorycalibrated replacement
cartridges · Power transformer · Vandalresistant steel wire
detector guards · Tamperproof screws · Horns and strobes
Applications · Parking Structure · Loading Dock Transport
Terminal · Golf Cart Maintenance · Battery Charging Area · Maintenance Garage · Hospital/Ambulance Bay · Fire/Police Station · Car Wash · Battery Charging Rooms · H2 & Hydrogen Tanks · Commercial Kitchen C3H8 · Boiler rooms
Certifications · Intertek Classified to:
UL 61010-1; and CSA C22.2 No. 61010-1-04 · COLA (City of Los Angeles) approved for carbon monoxide detection in commercial buildings and parking garages

2

When placing an order, please reference the Order Number (not the Model Number) where applicable.

PG1100-9-NCL

E³Point
Toxic & Combustible Gas Monitor

E³Point Analog (Single or Dual Gas) E³Point without sensor, wall mount, analog, 24 Vac/Vdc E³Point without sensor, wall mount, analog, 120 Vac E³Point without sensor, duct mount, analog, 24 Vac/Vdc Note: Sensor cartridge sold separately (see list below).

Model Number E3SA E3SAH E3DA

E³Point Network (Single Gas, BACnet or Modbus Selectable) E³Point without sensor, wall mount, Modbus/BACnet, 24 Vac/Vdc E³Point without sensor, duct mount, Modbus/BACnet 24 Vac/Vdc Note: Sensor cartridge sold separately (see list below).

Model Number E3SM E3DM

E³Point Sensor Cartridges Carbon monoxide (CO); -20° to 50°C (-4° to 122°F) Nitrogen dioxide (NO2); -40° to 50°C (-40° to 122°F) Hydrogen sulfide (H2S); -40° to 50°C (-40° to 122°F) Hydrogen (H2); -40° to 50°C (-40° to 122°F) Oxygen (O2); -40° to 50°C (-40° to 122°F) Methane (CH4); -40° to 50°C (-40° to 122°F) Propane (C3H8); -40° to 50°C (-40° to 122°F)

Model Number E3SCO E3NO2 E3H2S E3H2 E302 E3M E3P

E³Point Remote Gas Sensor (For use with E³Point Analog Units Only) E³Point remote sensor, carbon monoxide (CO) E³Point remote sensor, nitrogen dioxide (NO2) E³Point remote sensor, hydrogen sulfide (H2S) E³Point remote sensor, hydrogen (H2) E³Point remote sensor, oxygen (O2) E³Point remote sensor, methane (CH4) E³Point remote sensor, propane (C3H8)

Model Number E3SRMCO E3SRMNO2 E3SRMH2S E3SRMH2 E3SRMO2 E3SRMM E3SRMP

E³Point Accessories Protective wire guard for E³Point E³Point tamper-proof kit Splash guard enclosure Bump test kit; includes balloon adapter and quad gas cylinder: H2S (40 ppm), CO (200 ppm), CH4 (2.5%), O2 (10%) Test cap with hose for E³Point Regulator for 58 L / 103 L cylinder (0.5 LPM) for E³Point Polyurethane tubing, 6 mm O.D. x 4 mm I.D., 1 ft. / 30 cm

Model Number E3PT-CAGE E3T-PK ECLAB TEST-1A
­ ­ ­

Order Number 1309A0042 1309A0043 1309A0049
Order Number 1309A0047 1309A0051
Order Number 1309A0038 1309A0037 1309A0035 1309A0039 1309A0036 1309A0040 1309A0041
Order Number 1309A0060 1309A0057 1309A0058 1309A0059 1309A0056 1309A0061 1309A0062
Order Number 1309-0071 1309K0001 1309K0003 TEST-1A
131635-L3 M-502875 M-502730

PG1100-9-NCL

When placing an order, please reference the Order Number (not the Model Number) where applicable.

3

301C
Oxygen, Toxic & Combustible Gas Controller

The 301C Controller continuously monitors and controls toxic gases, combustible gases, and oxygen hazards. Designed for installation and operational simplicity, the 301C reduces the cost of installation and ownership.
Using an addressable RS-485 Modbus communication protocol, the 301C uses daisy chain wiring requiring only 2 pairs of wires to connect up to 96 transmitters on the 3 input channels. This simplifies installation, in turn lowering costs. The 301C's zoning and averaging abilities significantly reduce operational and maintenance costs.
Note: Non-branded versions of this product are available upon request.

User Friendly · Zero maintenance · Automatic quick self-test and
warm-up · Continuous alphanumeric display
Inexpensive and Reliable · Low installation costs · Allows for up to 126 zoning
groups which can save energy and extend fan and relay life · Manages up to 180 events with programmable latching alarms
Flexible Operation · Modbus compatible; with
BACnet/IP available · Interchangeable transmitters
able to detect different gases · Expands to handle up to 96
transmitters or relay modules · Programmable time delays · Integrated time clock enables
scheduling of system operations

Safety Measures · Full array of visual indicators and
integrated 65dBA alarm levels
· Fully programmable relays (can be set as fail-safe or not) Beneficial Options · Available in a heavy duty
industrial housing · Datalogging option
Applications All commercial building areas requiring multi-point gas monitoring
Certifications · Intertek Listed to:
UL 61010-1; and CSA C22.2 No. 61010-1-04

301C Gas Controllers 301C Controller with datalogger, BACnet/IP output, ABS polycarbonate enclosure 301C Controller with datalogger, ABS polycarbonate enclosure 301C Controller, ABS polycarbonate enclosure

Order Number 301-C-DLC-BIP 301-C-DLC 301-C

301C Gas Controller Interface Modules 301-ADI analog digital input converter (4-20mA to Modbus RS-485) 301AP annunciator panel for 301C Controller 301-R8 relay module with 8 relays, failsafe 301-R8 relay module with 8 relays 420I digital analog output converter, Modbus RS-485 to 4-20mA

Order Number 301-ADI 301-AP 301-R8-FS 301-R8 420-I

4

When placing an order, please reference the Order Number (not the Model Number) where applicable.

PG1100-9-NCL

Non Display Unit View at-a-glance normal
or fault status
Ductmount Unit Gain maximum flexibility
for installation

IAQPoint2
Indoor Air Quality Monitor

CO2 or VOC + temperature/humidity monitoring

Improve indoor air quality and cut energy costs with CO2 or VOC + temp/humidity monitoring for demand control ventilation. IAQPoint2 features a fully functional, multi-color, touch screen interface, the first of it's kind. IAQPoint2 operates on +24 Vac/Vdc. Analog output is 4-20 mA or 2-10 Vdc, switch selectable. Digital output is BACnet/ Modbus selectable or LonWorks. Available in wall mount and duct mount configurations.
Note: Non-branded versions of this product are available upon request.

UserFriendly Touchscreen Operation · Menu driven, customizable,
easytonavigate display · Large 1.9 x 2.6 in. (4.9 x
6.5 cm) VGA screen with easytoread LCD digits and graphical display
Flexible, MoneySaving Design · Simple wall or ductmount · Multianalog or digital (BACnet,
Modbus) options · DC and AC power; fits standard
junction box · 5 year sensor life with automatic
selfcalibration · Adjustable setpoints and
optional relay for local fan activation
3in1 Monitoring · Choose reliable CO2 or VOC
sensing technologies · Optimize room comfort through
temperature control
Green Attributes · Obtain LEED credits · Meet ASHRAE 15 standards · Low power consumption and
`sleep mode' feature · Optimize HVAC use and extend
life of components

Applications · Auditoriums · Conference rooms · Schools · Hospitals · Washrooms · Kitchens · Janitorial closets · Copier/printing rooms · Warehouses/shipping areas
Certifications · Intertek Listed to 3rd Editions
of: UL 61010-1; and CSA C22.2 No. 61010-1-12 · Intertek tested to EN 61010:2010, EN 61000-63:2007 + A1:2011, and EN 50270:2006, Type 2 Equipment for Immunity; and DLS tested to EN 50270:2006 for CE Mark · BTL (BACnet) · LonWorks

PG1100-9-NCL

When placing an order, please reference the Order Number (not the Model Number) where applicable.

5

IAQPoint2 Indoor Air Quality Monitor (continued)

IAQPoint2 Wall Mount Configurations

IAQPoint2 with Analog Output Carbon dioxide (CO2) monitor, wall mount, analog Carbon dioxide (CO2) monitor, wall mount, analog, relay Carbon dioxide (CO2) monitor, wall mount, analog, temp and rH Carbon dioxide (CO2) monitor, wall mount, analog, temp and rH, relay Carbon dioxide (CO2) monitor, wall mount, analog, display Carbon dioxide (CO2) monitor, wall mount, analog, relay, display Carbon dioxide (CO2) monitor, wall mount, analog, temp and rH, display Carbon dioxide (CO2) monitor, wall mount, analog, temp and rH, relay, display VOC monitor, wall mount, analog VOC monitor, wall mount, analog, relay VOC monitor, wall mount, analog, temp and rH VOC monitor, wall mount, analog, temp and rH, relay VOC monitor, wall mount, analog, display VOC monitor, wall mount, analog, relay, display VOC monitor, wall mount, analog, temp and rH, display VOC monitor, wall mount, analog, temp and rH, relay, display

Model Number IAQ-WAC IAQ-WAC-R IAQ-WAC-TRH IAQ-WAC-TRH-R IAQ-WAC-D IAQ-WAC-R-D IAQ-WAC-TRH-D IAQ-WAC-TRH-R-D IAQ-WAV IAQ-WAV-R IAQ-WAV-TRH IAQ-WAV-TRH-R IAQ-WAV-D IAQ-WAV-R-D IAQ-WAV-TRH-D IAQ-WAV-TRH-R-D

IAQPoint2 with Digital Output, BACnet and Modbus (Selectable)

Model Number

Carbon dioxide (CO2) monitor, wall mount, network, display

IAQ-WNC-D

Carbon dioxide (CO2) monitor, wall mount, network, relay, display

IAQ-WNC-R-D

Carbon dioxide (CO2) monitor, wall mount, network, temp and rH, display

IAQ-WNC-TRH-D

Carbon dioxide (CO2) monitor, wall mount, network, temp and rH, relay, display IAQ-WNC-TRH-R-D

VOC monitor, wall mount, network, display

IAQ-WNV-D

VOC monitor, wall mount, network, relay, display

IAQ-WNV-R-D

VOC monitor, wall mount, network, temp and rH, display

IAQ-WNV-TRH-D

VOC monitor, wall mount, network, temp and rH, relay, display

IAQ-WNV-TRH-R-D

IAQPoint2 with LonWorks Carbon dioxide (CO2) monitor, wall mount, LonWorks, display Carbon dioxide (CO2) monitor, wall mount, LonWorks, relay, display Carbon dioxide (CO2) monitor, wall mount, LonWorks, temp and rH, display Carbon dioxide (CO2) monitor, wall mount, LonWorks, temp and rH, relay, display VOC monitor, wall mount, LonWorks, display VOC monitor, wall mount, LonWorks, relay, display VOC monitor, wall mount, LonWorks, temp and rH, display VOC monitor, wall mount, LonWorks, temp and rH, relay, display

Model Number IAQ-WLC-D IAQ-WLC-R-D IAQ-WLC-TRH-D IAQ-WLC-TRH-R-D IAQ-WLV-D IAQ-WLV-R-D IAQ-WLV-TRH-D IAQ-WLV-TRH-R-D

Order Number 1508A1001 1508A1003 1508A1005 1508A1007 1508A1009 1508A1011 1508A1013 1508A1015 1508A1002 1508A1004 1508A1006 1508A1008 1508A1010 1508A1012 1508A1014 1508A1016
Order Number 1508A1017 1508A1019 1508A1021 1508A1023 1508A1018 1508A1020 1508A1022 1508A1024
Order Number 1508A1025 1508A1027 1508A1029 1508A1031 1508A1026 1508A1028 1508A1030 1508A1032

6

When placing an order, please reference the Order Number (not the Model Number) where applicable.

PG1100-9-NCL

IAQPoint2 Indoor Air Quality Monitor (continued)

IAQPoint2 Duct Mount Configurations

IAQPoint2 with Analog Output Carbon dioxide (CO2) monitor, duct mount, analog Carbon dioxide (CO2) monitor, duct mount, analog, relay Carbon dioxide (CO2) monitor, duct mount, analog, temp and rH Carbon dioxide (CO2) monitor, duct mount, analog, temp and rH, relay Carbon dioxide (CO2) monitor, duct mount, analog, display Carbon dioxide (CO2) monitor, duct mount, analog, relay, display Carbon dioxide (CO2) monitor, duct mount, analog, temp and rH, display Carbon dioxide (CO2) monitor, duct mount, analog, temp and rH, relay, display VOC monitor, duct mount, analog VOC monitor, duct mount, analog, relay VOC monitor, duct mount, analog, temp and rH VOC monitor, duct mount, analog, temp and rH, relay VOC monitor, duct mount, analog, display VOC monitor, duct mount, analog, relay, display VOC monitor, duct mount, analog, temp and rH, display VOC monitor, duct mount, analog, temp and rH, relay, display

Model Number IAQ-DAC IAQ-DAC-R IAQ-DAC-TRH IAQ-DAC-TRH-R IAQ-DAC-D IAQ-DAC-R-D IAQ-DAC-TRH-D IAQ-DAC-TRH-R-D IAQ-DAV IAQ-DAV-R IAQ-DAV-TRH IAQ-DAV-TRH-R IAQ-DAV-D IAQ-DAV-R-D IAQ-DAV-TRH-D IAQ-DAV-TRH-R-D

IAQPoint2 with Digital Output, BACnet and Modbus (Selectable) Carbon dioxide (CO2) monitor, duct mount, network, display Carbon dioxide (CO2) monitor, duct mount, network, relay, display Carbon dioxide (CO2) monitor, duct mount, network, temp and rH, display Carbon dioxide (CO2) monitor, duct mount, network, temp and rH, relay, display VOC monitor, duct mount, network, display VOC monitor, duct mount, network, relay, display VOC monitor, duct mount, network, temp and rH, display VOC monitor, duct mount, network, temp and rH, relay, display

Model Number IAQ-DNC-D IAQ-DNC-R-D IAQ-DNC-TRH-D IAQ-DNC-TRH-R-D IAQ-DNV-D IAQ-DNV-R-D IAQ-DNV-TRH-D IAQ-DNV-TRH-R-D

IAQPoint2 with LonWorks Carbon dioxide (CO2) monitor, duct mount, LonWorks, display Carbon dioxide (CO2) monitor, duct mount, LonWorks, relay, display Carbon dioxide (CO2) monitor, duct mount, LonWorks, temp and rH, display Carbon dioxide (CO2) monitor, duct mount, LonWorks, temp and rH, relay, display VOC monitor, duct mount, LonWorks, display VOC monitor, duct mount, LonWorks, relay, display VOC monitor, duct mount, LonWorks, temp and rH, display VOC monitor, duct mount, LonWorks, temp and rH, relay, display

Model Number IAQ-DLC-D IAQ-DLC-R-D IAQ-DLC-TRH-D IAQ-DLC-TRH-R-D IAQ-DLV-D IAQ-DLV-R-D IAQ-DLV-TRH-D IAQ-DLV-TRH-R-D

Order Number 1508A2001 1508A2003 1508A2005 1508A2007 1508A2009 1508A2011 1508A2013 1508A2015 1508A2002 1508A2004 1508A2006 1508A2008 1508A2010 1508A2012 1508A2014 1508A2016
Order Number 1508A2017 1508A2019 1508A2021 1508A2023 1508A2018 1508A2020 1508A2022 1508A2024
Order Number 1508A2025 1508A2027 1508A2029 1508A2031 1508A2026 1508A2028 1508A2030 1508A2032

PG1100-9-NCL

When placing an order, please reference the Order Number (not the Model Number) where applicable.

7

301EM-20 & 301IRFS
Refrigerant, Toxic & Combustible Gas Controller
and Networkable Sensors

R11, R123, R125, R134a, R22, R404a, R407c, R410a, R4310, R507a, CO, Cl2, H2S, NO2, NH3, O2, SO2, COMB

The 301EM-20 acts as a controller for up to 20 remote sensors and suits a variety of gas detection system solutions for Mechanical Rooms.
Particularly configured to meet ASHRAE 15, B-52 and International Mechanical Code requirements, the 301EM-20 is commonly used to optimize gas detection in mechanical and chiller rooms. A full complement of sensors (including toxic, oxygen, combustible gases and a full line of refrigerant sensors), horns, strobes and remote panels provide added flexibility to suit a variety of gas detection system solutions.
Note: Non-branded versions of this product are available upon request.

User Friendly · Easy to read LCD display · Autodiagnostic capabilities
Economical Solution · Cost-effective answer for
installation in Mechanical Rooms locations
Flexible Operation · Able to operate with up to 20
remote sensors at a time · Various types of sensors
available to simultaneously detect a range of different Refrigerant, Toxic and Combustible gases · Robust and reliable RS-485 Modbus communication

Output Adaptability · Three 24 Vdc alarm outputs and
four 4-20 mA outputs
Safety Measures · Four fully programmable relays · Three alarm levels with built-in
visual indicators and audible alarm
Beneficial Options · Convenient stand-alone or
network operation
Applications · Mechanical Rooms
Certifications · Intertek Classified (301IRFS)
Listed (301EM) to: UL 61010-1; and CSA C22.2 No. 61010-1-04

8

When placing an order, please reference the Order Number (not the Model Number) where applicable.

PG1100-9-NCL

301EM-20 & 301IRFS
Refrigerant, Toxic & Combustible Gas Controller
and Networkable Sensors

301EM Controllers Controller, Type 1 Canada (for use with R123) Controller, Type 2 Canada (for use with all other refrigerants) Controller, Type 3 US Controller with horn and strobe, Type 1 Canada Controller with horn and strobe, Type 2 Canada Controller with horn and strobe, Type 3 US

Order Number 301-EM-CA1 301-EM-CA2 301-EM-US3 301-EM-RFSA-CA1 301-EM-RFSA-CA2 301-EM-RFSA-US3

Annunciator Panel for use with 301EM-20 Remote panel Remote panel with horn and strobe

Order Number 301-EMRP 301-EMRP-RFSA

S301IRF Sensors for use with 301EM-20 (0-1000 ppm) R11 refrigerant gas sensor R123 refrigerant gas sensor R125 refrigerant gas sensor R134a refrigerant gas sensor R22 refrigerant gas sensor R404a refrigerant gas sensor R407c refrigerant gas sensor R410a refrigerant gas sensor R4310 refrigerant gas sensor R507a refrigerant gas sensor Note: S301IRF sensors operate on 12 Vdc power only. Higher voltage will result in damage to the sensor.

Order Number S301-IRF-R11 S301-IRF-R123 S301-IRF-R125 S301-IRF-R134A S301-IRF-R22 S301-IRF-R404A S301-IRF-R407C S301-IRF-R410A S301-IRF-R4310 S301-IRF-R507A

S301D2 Sensors for use with 301EM-20 Combustible explosion proof sensor - (GAIN 1.0-1.3 / Methane) Combustible explosion proof sensor - (GAIN 1.3-1.599 / Hydrogen) Combustible explosion proof sensor - (GAIN 1.6-1.999 / Propane, Ethanol) Combustible explosion proof sensor - (GAIN 2.0-2.219 / n-Pentane) Combustible explosion proof sensor - (GAIN 2.220-2.5 / Toluene) Combustible explosion proof sensor - (GAIN +2.5 / n-Decane) Carbon monoxide (CO) explosion proof sensor Chlorine (Cl2) explosion proof sensor Nitrogen dioxide (NO2) explosion proof sensor Hydrogen sulfide (H2S) explosion proof sensor Oxygen (O2) explosion proof sensor Sulfur dioxide (SO2) explosion proof sensor

Model Number S301D2COMB S301D2COMB S301D2COMB S301D2COMB S301D2COMB S301D2COMB S301D2CO S301D2CL2 S301D2NO2 S301D2H2S S301D2O2 S301D2SO2

Order Number 129570-L3 129426-L3 129427-L3 129428-L3 129429-L3 129430-L3 129431-L3 129435-L3 129432-L3 129433-L3 129436-L3 129434-L3

PG1100-9-NCL

When placing an order, please reference the Order Number (not the Model Number) where applicable.

9

301EM-20 & 301IRFS (continued)

EC-FX-EM Sensors for ammonia (NH3) detection for use with 301EM-20 Ammonia (NH3) Monitor, 4-20mA, Vulbus, 0-100 ppm, NEMA 1 Encl. Ammonia (NH3) Monitor, 4-20mA, Vulbus 0-250 ppm, NEMA 1 Encl. Ammonia (NH3) monitor, 4-20 mA, Modbus 0-500 ppm, NEMA 1 encl.

Model Number ECFX-100-N-EM ECFX-250-N-EM EC-F9-NH3-0/500-N1-EM

Order Number ECFX-100-N-EM ECFX-250-N-EM M-511010

EC-FX Replacements Cells
Replacement ammonia (NH3) cell, 0-100/250 ppm Note: Backwards compatible with EC-F2 & EC-F9 transmitters

Model Number EC-FX-NH3-LR

Order Number EC-FX-NH3-LR

EC-F9 Replacements Cells Replacement ammonia (NH3) cell Replacement ammonia (NH3) high range cell Replacement ammonia (NH3) cell

Model Number EC-F2-RC-NH3 EC-F2-RC-NH3 EC-F2-NH3-RC-EXP

Order Number M-507975 M-600043 M-600045

Options for use with 301EM-20 Break glass manual switch option for 301EM 301EM-20 light stack assembly with red lens, horn (85-103 dB), voltage rating, 24VDC LED Light Module, 24V AC/DC, green, for use with M-700123 LED Light Module, 24V AC/DC, blue, for use with M-700123 LED Light Module, 24V AC/DC, clear, for use with M-700123 LED Light Module, 24V AC/DC, yellow, for use with M-700123 LED Light Module, 24V AC/DC, amber, for use with M-700123 Vertical Stack Light Mounting Base w/cap Vertical Stack Light Mounting Base Metal guard for 301IRFS sensors 2-Position selector switch - 120 Vac Push button NO/NC - 120 Vac Push button NO/NC locked - 120 Vac 12/24 Vdc Power Supply, UL/cUL Listed, 2.5A @ 24Vdc

Model Number EMBG ­
­ ­ ­ ­ ­ ­ ­ IRFSENSORGUARD SEL-2POS-120V BP-120V-NO-NC BP-120V-LOCKED HPV5DC8UL

Order Number M-508617 M-700123
M-700327 M-700328 M-700329 M-700330 M-700331 M-700332 M-700333 M-505352 M-505913 M-505912 M-505911 HPV5DC8UL

10

When placing an order, please reference the Order Number (not the Model Number) where applicable.

PG1100-9-NCL

Self-Contained Breathing Apparatus (SCBA)
Aluminum Cylinders
Honeywell Analytics' Self-Contained Breathing Apparatus (SCBA) meets the demands of industrial users who want the finest respiratory protection against environments that are Immediately Dangerous to Life or Health (IDLH). The SCBA is designed to be a basic industrial unit, yet provides superior safety and comfort for industrial needs. The SCBA is available in medium face piece/bell alarm or hooded with medium nose cup/plain whistle alarm configurations. Note: All cylinders are shipped fully charged.

Breathing Apparatus SCBA, with low pressure 30 min. cylinder, medium facepiece, bell alarm SCBA, with low pressure 30 min. cylinder, hood with medium nose cup, plain whistle alarm SCBA, with high pressure 60 min. cylinder, medium facepiece, bell alarm
Breathing Apparatus Accessories Spare 30 min. cylinder, low pressure Spare 60 min. cylinder, high pressure Video, use/maintenance SCBA CD-ROM, use/maintenance SCBA Storage case for 1 SCBA wall unit Aluminum truck mounting bracket for SCBA

Order Number 888888 777777 555555
Order Number 915140 917160 995613 995612 83219 M-512890

PG1100-9-NCL

When placing an order, please reference the Order Number (not the Model Number) where applicable.

11

SQN8x Sample Draw
Refrigerant, Toxic & Combustible Sample-Draw
Gas Monitoring System

CO, COMB, NO2, O2, R11, R123, R125, R134A, R22, R227, R404A, R410A, R4310, R507

The new generation of the SQN8x series combines long proven sensing capability with state-of-the-art pumping technology and constant, high accuracy to yield a highly reliable sample draw gas detection system. Save costs through sensing capability to monitor gases in up to 8 different zones.

Note: Each configuration includes one sensor and tubing as indicated.

Safety Measures · 3 alarm relays · Audible alarm · Early low level warning alarm · Integrated flow loss surveillance
Reliable · Wide area of coverage · 2, 4 or 8 sample points · Proven sensing technology · Up to 2 gases

Applications · Chillers · Mechanical Rooms · Breweries · Wineries · Supermarkets
Certifications · Intertek Classified to:
UL 61010-1; and CSA C22.2 No. 61010-1-04

12

When placing an order, please reference the Order Number (not the Model Number) where applicable.

PG1100-9-NCL

SQN8x Sample Draw
Refrigerant, Toxic & Combustible Sample-Draw
Gas Monitoring System

 Gas 1 (required)

Refrigerant (R11)

Refrigerant (R123)

Refrigerant (R12)

Refrigerant (R134A)

Refrigerant (R22)

Refrigerant (R404A)

Refrigerant (407c)

Refrigerant (R410A)

Refrigerant (R4310)

Refrigerant (R507A)

Combustibles (% LEL)

Carbon monoxide (CO)

Nitrogen dioixide (NO2) Oxygen (O2)

 Number of Sampling Points

Two-point sample draw system (incl. 200ft tubing)

Four-point sample draw system (incl. 400 ft tubing)

Eight-point sample draw system (incl. 800 ft tubing)

 SQN8x Base Unit

Base unit

SQ8

 Gas 2 (optional)

R11

[ BLANK ] None

R123

R11

Refrigerant (R11)

R125

R123

Refrigerant (R123)

R134A

R125

Refrigerant (R12)

R22

R134A Refrigerant (R134A)

R404A

R22

Refrigerant (R22)

R407c

R404A Refrigerant (R404A)

R410A

R407c Refrigerant (407c)

R4310

R410A Refrigerant (R410A)

R507A

R4310 Refrigerant (R4310)

CMB

R507A Refrigerant (R507A)

CO

CMB

Combustibles (% LEL)

NO2

CO

Carbon monoxide (CO)

O2

NO2

Nitrogen dioixide (NO2)

O2

Oxygen (O2)

2

 Product Branding (optional)

[ BLANK ] With logo

4

N

No logo

8

Order number:

SQ8

-

-

-

(optional)

Example 1: A SQN8x configured with a four-point sample draw system and a single gas detector (R134A) with product branding would be SQ84R134A.
Example 2: A SQN8x configured with an eight-point sample draw system and dual gas detectors (R404A and CO) with no product branding would be SQ88R404ACON.

SQN8x Spare Sampling Tube 200 ft. sampling tube (0.17 in. I.D., 0.25 in. O.D.) 400 ft. sampling tube (0.17 in. I.D., 0.25 in. O.D.) 800 ft. sampling tube (0.17 in. I.D., 0.25 in. O.D.)
SQN8x Accessories Vacuum filter, 50 micron Sampling point with filter

Model Number 8XTL5 8XTL9 8XTL14

Order Number 0235-0295 0235-0296 0235-0297
Order Number M-510806 M-504183

PG1100-9-NCL

When placing an order, please reference the Order Number (not the Model Number) where applicable.

13

AirScanTM IR-F9
Standalone Refrigerant Gas Monitor for
Cold Storage

R134a, R22, R404a, R407a, R410a, R422d, R507a, HFO1234yf, CO2

The AirScanTM iR Sensor responds to refrigerants over the range of 0-1,000 ppm and features SensorCheckTM technology that continually monitors sensor performance.

The AirScanTM iR Sensor is an affordable microprocessor-based sensor that is selective to refrigerants and, because of its stabilised design platform, will provide years of service and will maintain the highest level of accuracy and reliability. This highly versatile sensor features SensorCheckTM, a unique technology that continuously monitors sensor performance that enables it to provide worry-free performance throughout the life of the sensor.

A true "diffusion" design sensor, the AirScanTM iR Sensor does not require either pumps or filters and allows all points of detection to be monitored perpetually, unlike sample draw systems. The versatile sensor is housed in a high mass metal bench structure that enables thermal stability and freedom from vibration.

IR-F9 units configured to a full scale of 0-500 ppm are designed to meet California Air Review Board (CARB) requirements.

Applications · Chiller Rooms · Food Processing

· Cold Storage · Supermarkets

AirScanTM IR-F9 with Commercial Enclosure Carbon dioxide (CO2) 0/10,000 ppm, commercial enclosure Carbon dioxide (CO2) 0/30,000 ppm, commercial enclosure HFO1234yf 0/500 ppm, commercial enclosure, CARBcompliant HFO1234yf 0/1000 ppm, commercial enclosure HFO1234yf 0/3000 ppm, commercial enclosure R22 0-500 ppm, commercial enclosure, CARBcompliant R22 0-1,000 ppm, commercial enclosure R134a 0-1,000 ppm, commercial enclosure R404a 0-1,000 ppm, commercial enclosure R407a 0-500 ppm, commercial enclosure, CARBcompliant R407a 0-1,000 ppm, commercial enclosure R410a 0-1,000 ppm, commercial enclosure R422d 0-500 ppm, commercial enclosure, CARBcompliant R422d 0-1,000 ppm, commercial enclosure R507a 0-1,000 ppm, commercial enclosure

Model Number

Order Number

IR-F9-CO2-1%-COM

M-700197

IR-F9-CO2-3%-COM

M-700198

IR-F9-HFO1234yf-0/1000-COM M-700265

IR-F9-HFO1234yf-0/1000-COM M-700270

IR-F9-HFO1234yf-0/1000-COM M-700275

IR-F9-R22-0-500-COM

M-700127

IR-F9-R22-0/1000-COM

M-700137

IR-F9-R134a-0/1000-COM

M-700138

IR-F9-R404a-0/1000-COM

M-700139

IR-F9-R407a-0-500-COM

M-700051

IR-F9-R407a-0/1000-COM

M-700061

IR-F9-R410a-0/1000-COM

M-700081

IR-F9-R422d-0-500-COM

M-700022

IR-F9-R422d-0/1000-COM

M-700031

IR-F9-R507a-0/1000-COM

M-700140

AirScanTM IR-F9 Accessories

Order Number

420MDBS-96D AirAlert 96d interface module 4-20 to RS485 with phoenix connector

M-511352*

Relay plug 4-20 signal term 3A 24 Vdc

M-600008

*Note: MDBS modules require factory-set configuration parameters. Please specify at time of ordering. Use of this module inside a sensor will invalidate any certifications.

14

When placing an order, please reference the Order Number (not the Model Number) where applicable.

PG1100-9-NCL

Sensepoint® XCD
Flammable, Toxic & Oxygen Gas Detector
and Transmitter

CH4, C3H8, C5H12, CO, CO2, H2, H2S, LEL, NO2, O2

The Sensepoint XCD range provides comprehensive monitoring of flammable, toxic and oxygen gas hazards in potentially explosive atmospheres, both indoors and outdoors. Users can modify detector operation using the LCD and magnet switches without ever needing to open the unit. This enables one-man, non-intrusive operation and reduces routine maintenance time and costs.

One-Stop Shop · Flammable (catalytic or infrared),
toxic and oxygen versions available · New and retrofit applications · Suitable for indoor or outdoor use · Aluminium explosion-proof housing · IP66 as standard
Proven and Reliable Sensor Technology · SurecellTM electrochemical
sensors · Reflex® sensor health check · Poison immune infrared sensors · Poison resistant catalytic bead
sensors · Long life sensors
Easy to Use · User friendly and intuitive
tricolour backlit display with digits, bar graph and icons · Fully configurable via magnetic switches · Selectable sink or source 4-20 mA output · Auto-inhibit during maintenance · Modbus communications for remote diagnostics/configuration

Cost Effective · Common transmitter platform · Minimal training required · Reduced spares · Non-intrusive, one-man
operation · Plug-in sensor replacement · Modbus multi drop option offers
cabling savings
Simple Installation · Plug-in display module removes
to give access to terminal area · Integral mounting bracket · 2 x ¾ in. NPT cable/conduit
entries · Removable plug/socket type
terminal blocks for ease of wiring · Sink/source switch to suit
preferred wiring topology
Range of Optional Accessories · Remote sensor gassing kit · Duct mounting kit · Calibration gas flow housing · Collecting cone
Applications · Boiler Rooms · Hospitals · Warehouses · Chemical storage
Certifications · US and Canadian · For additional information on
certifications and approvals contact Honeywell Analytics

PG1100-9-NCL

When placing an order, please reference the Order Number (not the Model Number) where applicable.

15

Sensepoint® XCD (continued)

Sensepoint XCD Transmitters Class I, Div. 1: UL & cUL Approvals

Order Number

Carbon monoxide (CO) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-250 ppm SPXCDULNCXM aluminum enclosure

Combustible (CH4) explosion proof transmitter (Cat Bead), 4-20 mA, 3 relays, Modbus, 0-100% SPXCDULNFXM aluminum enclosure

Combustible (C3H8) explosion proof transmitter (Cat Bead), 4-20 mA, 3 relays, Modbus, 0-100% SVIP3729 aluminum enclosure Custom calibration: SPXCDULNFXM PROPANE

Combustible (H2) explosion proof transmitter (Cat Bead), 4-20 mA, 3 relays, Modbus, 0-100% aluminum enclosure Custom calibration: SPXCDULNFXM HYDROGEN

SVIP3730

Combustible (C5H12) explosion proof transmitter (Cat Bead), 4-20 mA, 3 relays, Modbus, 0-100% aluminum enclosure Custom calibration: SPXCDULNFXM PENTANE

SVIP3731

Hydrogen sulfide (H2S) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-50 ppm SPXCDULNHXM aluminum enclosure

Nitrogen dioxide (NO2) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-50 ppm SPXCDULNNXM aluminum enclosure

Oxygen (O2) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-25% aluminum enclosure SPXCDULNO1M

Hydrogen (H2) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-1,000 ppm aluminum enclosure

SPXCDULNG1M

Sensepoint XCD Transmitters Class I, Div. 1: UL Approval
Combustible explosion proof transmitter (IR), methane (CH4) 4-20 mA, 3 relays, Modbus, 0-100% LEL aluminum enclosure
Combustible explosion proof transmitter (IR), propane (C3H8) 4-20 mA, 3 relays, Modbus, 0-100% LEL aluminum enclosure
Carbon dioxide (CO2) explosion proof transmitter (IR), 4-20 mA, 3 relays, Modbus, 0-2% Vol aluminum enclosure
EC: Electrochemical Cell / Cat Bead: Catalytic Bead / IR: Infrared

Order Number SPXCDULNRXM
SPXCDULNPXM
SPXCDULNB1M

16

When placing an order, please reference the Order Number (not the Model Number) where applicable.

PG1100-9-NCL

Sensepoint® XCD (continued)

XCD Consumables Class I, Div. 1 Flammable CAT 0-100% LEL (20 to 100.0% LEL) Oxygen (O2) 25.0%/Vol only Hydrogen sulfide (H2S) 0-50 ppm (10.0 to 100.0 ppm) Carbon monoxide (CO) 0-500 ppm (100 to 1000 ppm) Carbon dioxide (CO2) 0-2% VOL Hydrogen (H2) 0-1000 ppm only Nitrogen dioxide (NO2) 10-50 ppm Flammable IR 0-100% LEL methane (20 to 100.0% LEL) Flammable IR 0-100% LEL propane (C3H8) (20.0 to 100.0% LEL, 10% LEL)
XCD Spares, Class I, Div. 1 Sensepoint XCD standard weather protection Sensor retainer with locking screw Allen key for stopper Hex wrench for earth screw Earth bracket and screws Magnetic wand
XCD Accessories, Class I, Div. 1 Calibration cap Collecting cone for use with lighter than air gases Duct mounting kit Mounting bracket (inc. bolts, nuts, brackets) Sunshade / deluge protection Sensepoint XCD combustible calibration kit Sensepoint XCD toxic calibration kit

Order Number SPXCDXSFXSS SPXCDXSO1SS SPXCDXSHXSS SPXCDXSCXSS SPXCDXSB1SS SPXCDXSG1SS SPXCDXSNXSS SPXCDXSRXSS SPXCDXSPXSS
Order Number SPXDCWP SPXCDSRLS SPXCDAKS SPXCDHWES SPXCDEBS SPXCDMAG
Order Number S3KCAL SPXCDCC SPXCDDMK SPXCDMTBR SPXCDSDP XCDCOMBKIT XCDTOXKIT

PG1100-9-NCL

When placing an order, please reference the Order Number (not the Model Number) where applicable.

17

Sensepoint® XCD RTD
Remote Toxic & Oxygen Gas Detector
and Transmitter

Cl2, CO, H2, H2S, NH3, NO, NO2, O2, SO2

Sensepoint XCD RTD from Honeywell Analytics makes it easy on your maintenance team, time and budget when faced with the challenge of monitoring toxic gases in Class I, Div. 2 areas.
You can mount the unit up to 100 feet from the transmitter to obtain maximum gas detection coverage in areas not easily accessible or where the sensor would not be visible, as in high-or low-level concealed areas, or detection outside the room being monitored. XCD RTD offers unrivaled flexibility and performance via its easily recognizable display (traffic light pattern) to convey safety status, communication and mounting options, and onboard diagnostics.

Reduce Cost of Ownership Over Life of the Product · Cut stocking and procurement
costs with a common transmitter platform · Reduce maintenance time and expense with non-intrusive, one-man operation · Simplify maintenance with plugin, removable sensor · Reduce inspection and training time with tri-color `traffic light' display conveying safety status at a glance · Simplify set-up and configuration with non-intrusive magnetic switches
Applications · Class I, Div 2 Areas
Certifications · US and Canadian · For additional information on
certifications and approvals contact Honeywell Analytics

Gain Added Flexibility, Reliability and Performance · Extend gas sensing element
up to 100 ft. (30 m) from transmitter; mount in the most difficult to access areas · Reduce likelihood of human error via on-board diagnostics and easy-to-read display · Protect against dust/water ingress with IP66/67 rated stainless steel or aluminum enclosure · Prevent false alarms with autoinhibit during maintenance · Select sink or source 4-20 mA output; integral or remote configuration · Full range of accessories and purchase options let you choose the remote monitoring system that's right for your application

Sensor Fitted to Remote Junction Box
Note: Conduit and fittings not included

18

When placing an order, please reference the Order Number (not the Model Number) where applicable.

PG1100-9-NCL

Sensepoint® XCD RTD
Remote Toxic & Oxygen Gas Detector
and Transmitter

Sensepoint XCD RTD Transmitters Class I, Div. 2: UL & cUL Approvals

Order Number

Oxygen (O2) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-25% aluminum enclosure, Class I, Div. 2

SPXCDULNO2M

Hydrogen sulfide (H2S) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-50 ppm SPXCDULNH2M aluminum enclosure, Class I, Div. 2

Carbon monoxide (CO) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-200 ppm SPXCDULNC2M aluminum enclosure, Class I, Div. 2

Hydrogen (H2) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-1,000 ppm aluminum enclosure, Class I, Div. 2

SPXCDULNG2M

Nitrogen dioxide (NO2) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-10 ppm SPXCDULNN2M aluminum enclosure, Class I, Div. 2

Ammonia (NH3) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-50 ppm aluminum enclosure, Class I, Div. 2

SPXCDULNA2M

Chlorine (Cl2) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-5 ppm aluminum enclosure, Class I, Div. 2

SPXCDULNL2M

Sulfur dioxide (SO2) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-15 ppm aluminum enclosure, Class I, Div. 2

SPXCDULNS2M

Nitric oxide (NO) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-100 ppm aluminum enclosure, Class I, Div. 2

SPXCDULND2M

Sensepoint XCD RTD Transmitters Class I, Div. 2: UL & cUL Approvals with Remote Mount Hardware

Order Number

Oxygen (O2) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-25% aluminum enclosure, Class I, Div. 2 with remote mount hardware

SPXCDULNO2RM

Hydrogen sulfide (H2S) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-50 ppm SPXCDULNH2RM aluminum enclosure, Class I, Div. 2 with remote mount hardware

Carbon monoxide (CO) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-200 ppm SPXCDULNC2RM aluminum enclosure, Class I, Div. 2 with remote mount hardware

Hydrogen (H2) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-1,000 ppm aluminum enclosure, Class I, Div. 2 with remote mount hardware

SPXCDULNG2RM

Nitrogen dioxide (NO2) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-10 ppm SPXCDULNN2RM aluminum enclosure, Class I, Div. 2 with remote mount hardware

Ammonia (NH3) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-50 ppm aluminum enclosure, Class I, Div. 2 with remote mount hardware

SPXCDULNA2RM

Chlorine (Cl2) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-5 ppm aluminum enclosure, Class I, Div. 2 with remote mount hardware

SPXCDULNL2RM

Sulfur dioxide (SO2) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-15 ppm aluminum enclosure, Class I, Div. 2 with remote mount hardware

SPXCDULNS2RM

Nitric oxide (NO) explosion proof transmitter (EC), 4-20 mA, 3 relays, Modbus, 0-10 ppm aluminum enclosure, Class I, Div. 2 with remote mount hardware

SPXCDULND2RM

EC: Electrochemical Cell / Cat Bead: Catalytic Bead / IR: Infrared

PG1100-9-NCL

When placing an order, please reference the Order Number (not the Model Number) where applicable.

19

Sensepoint® XCD RTD (continued)

XCD Sensors Class I, Div. 2 Oxygen (O2) 0-25%Vol sensor Hydrogen sulfide (H2S) 0-50 ppm sensor Carbon monoxide (CO) 0-200 ppm sensor Hydrogen (H2) 0-1,000 ppm sensor Nitrogen dioxide (NO2) 0-10 ppm sensor Ammonia (NH3) 0-50 ppm sensor Chlorine (Cl2) 0-5 ppm sensor Sulfur dioxide (SO2) 0-15 ppm sensor Nitric oxide (NO) 0-100 ppm sensor

Order Number 2106B1830 2106B1801 2106B1806 2106B1817 2106B1822 2106B1813 2106B1810 2106B1820 2106B1818

XCD Replacement Cells Class I, Div. 2 Oxygen (O2) 0-25%Vol replacement cell kit Hydrogen sulfide (H2S) 0-50 ppm replacement cell kit Carbon monoxide (CO) 0-200 ppm Cell Kit Hydrogen (H2) 0-1,000 ppm replacement cell kit Nitrogen dioxide (NO2) 0-10 ppm replacement cell kit Ammonia (NH3) 0-50 ppm replacement cell kit Chlorine (Cl2) 0-5 ppm replacement cell kit Sulfur dioxide (SO2) 0-15 ppm replacement cell kit Nitric oxide (NO) 0-100 ppm replacement cell kit

Order Number 2106B1545 2106B1549 2106B1548 2106B1597 2106B1599 2106B1596 2106B1547 2106B1546 2106B1594

XCD Spares and Accessories, Class I, Div. 2 Sensepoint XCD RTD transmitter, 4-20 mA, 3 relays, Modbus Sensepoint XCD RTD remote junction box, 3 terminal Series 2000 weather housing for use with toxic sensor Series 2000 flow housing assembly Series 2000 flow housing assembly plastic Toxic calibration kit with calibration cover, removal tool, potentiometer adjustment tool Note: Flow housing (02000-A-1645) is required and must be ordered separately.

Order Number SPXCDULNTX4M 2430-0021 02000-A-1635 02000-A-1645 02000-A-3120 2106B2114

XCD RTD Calibration Kit
Sensepoint XCD RTD calibration kit - includes calibration cover, potentiometer, adjustment tool, flow housing, regulator and tubing (2106B2114, 02000-A-1645, 998-100-012, 998-100-003, 998-100-004)

Order Number XCDRTDKIT

20

When placing an order, please reference the Order Number (not the Model Number) where applicable.

PG1100-9-NCL

Sensepoint XCD RFD

Transmitter Display

705 Sensor

LEL (*1­*8)
The Sensepoint RFD is a remote flammable detection system for LEL monitoring applications. The XCD RFD combines the XCD transmitter with the 705 combustible sensor, and is certified for use in ClassI Div.1 rated areas. The XCD RFD offers one man, non-intrusive, operation and reduces routine maintenance time and costs. The XCD transmitter includes two programmable alarm/fault relays as well as an industry standard 4-20mA output. Calibration and relay operation of the transmitter may be adjusted via the transmitters' backlit LCD. Outputs are automatically inhibited during adjustment thereby reducing the risk of false alarm at the control panel during maintenance.
Sensepoint RFD is supplied with all necessary accessories for easy installation. It can be mounted on a wall or 2 in. round support pole using the universal bracket provided. The detector is ideal for use with either conduit or steel wire armored cable and glands and includes both 3/4 in. NPT and M20 entries to the junction box.
Sensepoint RFD offers easy installation and fast routine operation. Compatible with both standard and high temperature variants of the Sensepoint and 705 flammable sensors from Honeywell Analytics the overall flexibility of the product range is increased. Meets ClassI Div.1 UL performance standards.
Note: Conduit and fittings not included

Sensor Fitted to Remote Junction Box
Note: Conduit and fittings not included

Transmitter - cCSAus Certified for North America (ClassI, Div.1, Groups B, C & D) Transmitter with LM25, 3/4 in. NPT entry, Modbus, aluminum

Order Number SPXCDULNRFDM

Sensor 705 combustible sensor - aluminum - cat bead (SG16B) 0-100% LEL, UL / CSA approved 705 high temperature combustible sensor (150°C) 3/4 in. NPT threads, UL approved

Order Number 00705-A-1733 00705-A-1735

Junction Box UL/CSA aluminum 3 wire junction box

Order Number 2430-0021

Kits - cCSAus Certified for North America (ClassI, Div.1, Groups B, C & D) All kits include transmitter, sensor, and junction box.
Transmitter with LM25, 3/4 in. NPT entry, Modbus, aluminum, 705 sensor, and 3 wire junction box
Transmitter with LM25, 3/4 in. NPT entry, Modbus, aluminum, 705 High Temp sensor, and 3 wire junction box

Order Number XCDRFDLM XCDRFDLMH

PG1100-9-NCL

When placing an order, please reference the Order Number (not the Model Number) where applicable.

21

Sensepoint XCD RFD (continued)

Accessories Pipe mounting bracket (inc. fixings and hex wrench set) Sunshade / deluge protection Weather protection stainless steel for 705 HT Nylon weather protection for combustible sensor Weather protection housing Duct mount adaptor assembly (requires 1283-1084) Sensepoint adaptor interface kit (requires 1283-1047) Calibration gas flow adaptor (for use with 705 sensors) Collecting cone (for use with MPD, Sensepoint and 705 sensors)
XCD RFD Calibration Kit Sensepoint XCD RFD calibration kit - includes tubing, flow adaptor, regulator and carrying case (998-100-004, 00780-A-0035, 998-100-012 (1.5LPM), 998-100-003)

Order Number SPXCDMTBR SPXCDSDP 00780-A-0076 02000-A-1640 02000-A-1635 1283-1047 1283-1084 00780-A-0035 02000-A-1642
Order Number XCDRFDKIT

22

When placing an order, please reference the Order Number (not the Model Number) where applicable.

PG1100-9-NCL

ToxyPoint
Two-Wire Transmitter
CO

The ToxyPoint two wire transmitter provides continuous monitoring for carbon monoxide in ambient air and is designed to reduce the overall cost of ownership with a lower initial investment, eliminating maintenance costs and minimising building electrical operating costs. 2-Year disposable sensor, no calibration required.

ToxyPoint TwoWire Transmitter ToxyPoint: disposable 2wire 420 mA carbon monoxide (CO) transmitter

Model Number TP1-M

Order Number M-503340

PG1100-9-NCL

When placing an order, please reference the Order Number (not the Model Number) where applicable.

23

Midas®
Extractive Gas Detector

AsH3, B2H6, BCl3, BF3, Br2, C4F6, C5F8, CH2F2, CH3F, CH4, Cl2, ClO2, CO, CO2, F2, GeH4, H2, H2Cl2Si, H2S, HBr, HCl, HCN, HF, NF3, NH3, NO, NO2, O2, O3, PH3, Si2H6, SiH4, SO2, WF6

Extractive Midas® transmitters (universal) operate with sensor cartridges, for use as a local gas detector. Sensor Cartridges must be ordered separately. Units are powered by 24 Vdc or via Power over Ethernet (PoE). Transmitters provides 0-22 mA analog and Modbus/TCP Ethernet as standard outputs. Integral relays for A1, A2 and fault are included, and may be configured normally open or normally closed, latching or nonlatching. Transmitters include (1) PG16 gland fitting for power in and relays out, 1/4 in. O.D.x 1/8 in. I.D. Sample Inlet tubing (10 ft. / 3m), 1/4 in. O.D x 3/16 in. I.D. Exhaust tubing (10 ft. / 3m), and a sample line tubing duct adapter (1283K1090).

Note: Order a sensor cartridge separately for each transmitter.

Applications · Hospitals · School Labs · Chemical Storage Areas

Certifications · Intertek Classified to: UL 61010-1;
and CSA C22.2 No. 61010-1-04 · Intertek tested to EN 61010

Extractive Transmitter for Universal Gas Detection Midas® Extractive Transmitter

Order Number MIDAS-T-004

Pyrolyzer Module for NF3 Gas Detection (order separate transmitter unit) Pyrolyzer Midas® transmitters provide detection of NF3 specifically. Unit includes a snap on pyrolyzer module that operates with any Universal Midas® Extractive Transmitter (order separately) and (1) Freon in line filter. Units are
powered via direct connection to transmitter unit.

Order Number

Midas® Pyrolyzer Module

MIDAS-T-0P3

Note: Order the NF3 cartridge (MIDAS-S-HFX) and ventilated top cover (MIDAS-A-039) separately.

High Temperature Pyrolyzer Module for Perfluoro Compounds (PFC) Gas Detection Higher Temperature Pyrolyzer Midas® transmitters provide detection of C4F6, C5F8 and other gases. Unit includes a snap on pyrolyzer module that operates with any Universal Midas® Extractive Transmitter (order separately). Units are powered via direct connection to transmitter unit. Pyrolyzer includes installation screws.

Order Number

Midas® High Temperature Pyrolyzer Module

MIDAS-T-HTP

Note: Order transmitter uint, PFC cartridge (MIDAS-S-CFX) and ventilated top cover (MIDAS-A-039) separately.

LonWorks Module for Midas® Transmitter Connection Optional LonWorks interface module that mounts to and connects with any single, universal Midas® extractive transmitter with or without Pyrolyzer (order these separately) to provide bi-directional LonWorks connectivity; remote reset and remote control of the onboard relays. Unit is 24 Vdc powered and provides power and communications directly to the attached Midas® transmitter using special Ethernet cross over cable (supplied). Includes mounting bracket to the Midas® transmitter; rear panel installation screws are not supplied.

Order Number

Midas® LonWorks Interface Module

MIDAS-T-LON

Quad LonWorks Module for External Transmitter Connection Optional Modbus/TCP to LonWorks converter gateway that can connect up to 4 Midas® transmitters (with or without Pyrolyzers) to a LonWorks network. Requires separate 24 Vdc power supply and Ethernet connector cables. Suitable for DIN rail mounting. Consult Honeywell Analytics for full technical details. Access to LonMaker programming is required (not included).

Order Number

Midas® Quad LonWorks Module

MIDAS-A-035

24

When placing an order, please reference the Order Number (not the Model Number) where applicable.

PG1100-9-NCL

Midas®
Extractive Gas Detector

Midas® Transmitter and Cartridge Combined Kits A complete kit including one universal Midas® transmitter unit (Midas-T-001) and one Midas® sensor cartridge can be ordered as a combined package. Each cartridge is supplied with an extended 2 year warranty. This is the recommended kit for a new installation of a complete gas detection circuit. Cartridge and Transmitter are packaged separately for ease of installation. The detectable range is listed (outside of deadband). With the exception of O2 (where ambient concentration is typically 20.9%), the sensors will display zero when no gas is present.

Order Number

Ammonia (NH3)
Arsine (AsH3), germane (GeH4)
Boron trichloride (BCl3), dichlorosilane (H2Cl2Si), hydrogen bromide (HBr), hydrogen chloride (HCl)
Boron trifluoride (BF3), hydrogen fluoride (HF), nitrogen trifluoride (NF3) Note: Must order MIDAS-T-00P Pyro, tungsten hexafluoride (WF6)
Boron trifluoride (BF3), low level, hydrogen fluoride (HF), low level (LDL = 0.22 ppm), tungsten hexafluoride (WF6), low level
Bromine (Br2), chlorine dioxide (ClO2)
Difluoromethane (CH2F2) Note: Contact your local RSM or Inside Sales for special ordering requirements.

MIDAS-K-NH3 MIDAS-K-ASH MIDAS-K-HCL MIDAS-K-HFX
MIDAS-K-HFL
MIDAS-K-BR2 MIDAS-K-CFX

Carbon dioxide (CO2) Carbon monoxide (CO)

MIDAS-K-CO2 MIDAS-K-COX

Chlorine (Cl2), fluorine (F2) Hydrogen (H2) Hydrogen cyanide (HCN)

MIDAS-K-HAL MIDAS-K-H2X MIDAS-K-HCN

Hydrogen sulfide (H2S) Hydrogen (H2), methane (CH4) Nitric oxide (NO)

MIDAS-K-H2S MIDAS-K-LEL MIDAS-K-NOX

Nitrogen dioxide (NO2) Oxygen (O2) Ozone (O3) Phosphine (PH3) Silane (SiH4) (low level) Silane (SiH4), disilane (Si2H6) Sulfur dioxide (SO2) TEOS

MIDAS-K-NO2 MIDAS-K-O2X MIDAS-K-O3X MIDAS-K-PH3 MIDAS-K-SHL MIDAS-K-SHX MIDAS-K-SO2 MIDAS-K-TEO

Note: To detect NF3, a separate pyrolyzer module (MIDAS-T-00P) must also be ordered.

PG1100-9-NCL

When placing an order, please reference the Order Number (not the Model Number) where applicable.

25

Midas® Extractive Gas Detector (continued)

Mounting Accessories Midas® "L" bracket for vertical mounting Midas® DIN rail mounting kit Ventilated Midas® top cover for pyrolyzer applications Flexible conduit, 21 in. length Flexible conduit, 27 in. length 2A 24 Vdc power supply in vented NEMA4 enclosure 5A 24 Vdc power supply in vented NEMA4 enclosure

Order Number MIDAS-A-032 MIDAS-A-036 MIDAS-A-039 0235-0128 0235-0163 MVIP3632-2A MVIP3632-5A

Duct Sampling Adaptors Duct adapter for 1/4 in. O.D. tubing for 4-16 in. round ducts Union fitting 1/4 in. tube, polypropylene

Order Number 1283K1090 0235-0095

Tubing and External Sample Line Filters

Order Number

End of line particulate filter, disposable

780248

End of line particulate filter for corrosive gases, this disposable filter provides protection against particulate build up in the sample line when monitoring for corrosive gases.

1991-0147

Union fitting - use to connect disposable filter to end of line

0235-0095

End of line particulate filter for corrosive gases, this reusable filter housing provides protection

1830-0055

against particulate build up in the sample line when monitoring for corrosive gases. Replaceable filter

element (P/N 0235-1072) purchased separately

Replacement "corrosive" filter elements (pack of 100), for use in 1830-0055 filter housing

0235-1072

Freon filter for NF3 pyrolyzing gas detector

1830-0027

Freon filter for NF3 pyrolyzing gas detector (extended life) Note: Not for use with C4F6, C5F8, CH3F, CH2F2 pyrolyzers
Tubing Teflon® FEP 1/4 in. OD x 1/8 in. ID (sample inlet) (per ft.)

1830-0080 102599

Tubing Teflon® FEP 1/4 in. OD x 1/8 in. ID (sample Inlet) (100 ft. continuous length)

1991-0136

Tubing polypropylene 1/4 in. OD X 3/16 in. ID (exhaust) (per ft.)

100440

Tubing polypropylene 1/4 in. OD X 3/16 in. ID (exhaust) (100 ft. continuous length)

1991-0137

26

When placing an order, please reference the Order Number (not the Model Number) where applicable.

PG1100-9-NCL

Midas® Extractive Gas Detector (continued)

Midas® Sensor Cartridges Cartridges are required for all of the above transmitters sensors at time of purchase and for replacement. Several Midas® cartridges can be configured via the transmitter to read a number of different gases based on a common chemical family. Actual details for the sensor detection range are included in the sensor cartridge data sheet and the Midas® technical manual. Midas® sensor cartridges can be ordered as part of a Kit with the universal Midas® transmitter, or as a replacement part with either standard or extended warranty cover. The detectable range is listed (outside of deadband). With the exception of O2 (where ambient concentration is typically 20.9%), the sensors will display zero when no gas is present.

Order Number

Ammonia (NH3) Arsine (AsH3), germane (GeH4)

MIDAS-E-NH3 MIDAS-E-ASH

Boron trichloride (BCl3), dichlorosilane (H2Cl2Si), hydrogen bromide (HBr), hydrogen chloride (HCl) MIDAS-E-HCL

Boron trifluoride (BF3), hydrogen fluoride (HF), nitrogen trifluoride (NF3), tungsten hexafluoride (WF6) MIDAS-E-HFX

Boron trifluoride (BF3), low level, hydrogen fluoride (HF), low level (LDL = 0.22 ppm), tungsten hexafluoride (WF6), low level

MIDAS-E-HFL

Bromine (Br2), chlorine dioxide (ClO2)

MIDAS-E-BR2

Difluoromethane (CH2F2), hexafluorobutadiene (C4F6), methyl fluoride (CH3F), octofluorocyclopentene MIDAS-E-CFX (C5F8), sulfur hexafluoride (SF6)

Carbon dioxide (CO2) Carbon monoxide (CO)

MIDAS-E-CO2 MIDAS-E-COX

Chlorine (Cl2), fluorine (F2)

MIDAS-E-HAL

Diborane (B2H6)

MIDAS-E-B2H

Hydrogen (H2)

MIDAS-E-H2X

Hydrogen cyanide (HCN)

MIDAS-E-HCN

Hydrogen sulfide (H2S)

MIDAS-E-H2S

Hydrogen (H2), methane (CH4) Nitric oxide (NO)

MIDAS-E-LEL MIDAS-E-NOX

Nitrogen dioxide (NO2) Oxygen (O2)

MIDAS-E-NO2 MIDAS-E-O2X

Ozone (O3) Ozone (O3) (high level)

MIDAS-E-O3X MIDAS-E-O3H

Phosphine (PH3) Silane (SiH4) (low level)

MIDAS-E-PH3 MIDAS-E-SHL

Silane (SiH4), disilane (Si2H6)

MIDAS-E-SHX

Sulfur dioxide (SO2)

MIDAS-E-SO2

TEOS

MIDAS-E-TEO

Calibration Kit Midas® calibration kit

Order Number MIDASCALKIT

PG1100-9-NCL

When placing an order, please reference the Order Number (not the Model Number) where applicable.

27

Commercial Accessories

Strobe-Horn DC strobe and horn (P4W-P) Strobe and horn RED lens - 120 Vac - indoor application Strobe and horn BLUE lens - 120 Vac - indoor application Strobe and horn AMBER lens - 120 Vac - indoor application 2-wire horn strobe, standard candela, white, wall, 12 or 24 Vdc 2-wire horn strobe, high candela, white, wall, 12 or 24 Vdc 2-wire outdoor horn strobe, standard candela, white, wall, 12 or 24 Vdc 2-wire outdoor horn strobe, high candela, white, wall, 12 or 24 Vdc 2-wire horn strobe, standard candela, white, ceiling, 12 or 24 Vdc 2-wire horn strobe, high candela, white, ceiling, 12 or 24 Vdc Strobe and horn, RED lens, 24 Vac, indoor or outdoor Strobe and horn, BLUE lens, 24 Vac, indoor or outdoor Strobe and horn, AMBER lens, 24 Vac, indoor or outdoor Stackable base with horn - 120 Vac - indoor or outdoor Stackable strobe - RED Lens - 120 Vac - indoor or outdoor Stackable strobe - BLUE Lens - 120 Vac - indoor or outdoor Stackable strobe - AMBER Lens - 120 Vac - indoor or outdoor MT4 multitone strobe

Model Number FHS-240 STASR STASB STASA P2W-P P2WH-P P2WK-P P2WHK-P PC2W-P PC2WH-P STASR24VAC STASB24VAC STASA24VAC STACKSTASBASE STACKSTASR STACKSTASB STACKSTASA WHEELOCK

Strobe Strobe RED lens - 120 Vac - indoor or outdoor application Strobe BLUE lens - 120 Vac - indoor or outdoor application Strobe AMBER lens - 120 Vac - indoor or outdoor application Strobe (NEMA4X) RED - 120 Vac - Div. 2 hazardous loc Strobe (NEMA4X) BLUE - 120 Vac - Div. 2 hazardous loc Strobe (NEMA4X) AMBER - 120 Vac - Div. 2 hazardous loc Explosion Proof strobe - 120 Vac - Class I, Div. 2 - wall mount Strobe, standard candela, white, wall mount Strobe, standard candela, white, ceiling mount Strobe, high candela, white, wall mount Outdoor strobe, standard candela, white, wall mount Outdoor strobe, high candela, white, wall mount Speaker strobe, standard candela, white, wall mount Speaker strobe, high candela, white, wall mount Speaker strobe, standard candela, high dB, white, wall mount Outdoor speaker strobe, standard candela, white, wall mount Sync Module 3 (white) Sync Module 3 (red)

Model Number STAS50R120V STAS50B120V STAS50A120V STASHAZR120V STASHAZB120V STASHAZA120V STASDEFMUR120 SW-P SCW-P SWH-P SWK-P SWHK-P SPSW-P SPSWH-P SPSWV-P SPSWK-P MDL3W MDL3R

Order Number P4W-P M-503258 M-500902 M-503257 P2W-P P2WH-P P2WK-P P2WHK-P PC2W-P PC2WH-P M-506949 M-512023 M-512024 M-500877 M-501809 M-501807 M-501806 WH-126143
Order Number M-502831 M-500901 M-500710 M-502022 M-502021 M-502020 M-501763 SW-P SCW-P SWH-P SWK-P SWHK-P SPSW-P SPSWH-P SPSWV-P SPSWK-P MDL3W MDL3R

28

When placing an order, please reference the Order Number (not the Model Number) where applicable.

PG1100-9-NCL

Commercial Accessories

Horn Horn - 120 Vac - indoor application Horn (NEMA4X) - 120 Vac - indoor or outdoor application Explosion proof horn - 120 Vac - Class I Div. 1 and 2, tone selectable Explosion proof horn - 120 Vac - Class I Div. 1

Model Number HORN120VAC HORNWith P120V HORNEXPL120VTS HORNEXPL120V

Lens Wall mount lens attachment, blue Wall mount lens attachment, red Wall mount lens attachment, amber Wall mount lens attachment, green

Model Number LENS-B LENS-R LENS-A LENS-G

Power Supplies 120 Vac to 24 Vdc adapter for System Sensor horn and strobe units 24 Vac transformer, rate at 50 VA

Model Number MP120K VA201TA50

Power Supplies: UL or UL/cUL Approved 12/24 Vdc power supply, UL/cUL listed, 2.5A @ 24 Vdc 24 Vdc power supply, 6.5A UL approved 24 Vac power supply, UL/cUL listed, 100 VA, 4.1A @ 24 Vac 24 Vac power supply, UL/cUL listed, 200 VA, 8.3 @ 24 Vac 24 Vac power supply, UL/cUL listed, 400 VA, 16.6A @ 24 Vac

Model Number HPV5DC8UL PS-24-150-N12 HPTV2404UL HPV2401UL HPV2416-1UL

Uninterruptable Power Supplies (UPS) UPS750VA 120V APC Smart-UPS 750 VA UPS1000VA 120V APC Smart-UPS 1000 VA UPSAPCBP, battery unit for APC Smart-UPS

Order Number M-507960 M-508370 SMX48RMBP2U

Order Number M-503973 M-503974 0130-0018 M-501767
Order Number LENS-B LENS-R LENS-A LENS-G
Order Number MP120K M-503380
Order Number HPV5DC8UL M-600400 HPTV2404UL HPV2401UL HPV2416-1UL

PG1100-9-NCL

When placing an order, please reference the Order Number (not the Model Number) where applicable.

29

Calibration Equipment

Gas Legend % LEL CBrF3 / R13B1 CCl3F / R11 CF3-CH2F / R134A CH2F2 / R32 CH3CHF2 / R125 CH4 CHCl2CF3 / R123 CHClF2 / R22

Combustibles

Cl2

Trifluorobromomethane

ClO2

Trichloromonofluoromethane CO

1,1,1,2-Tetrafluoroethane CO2

Difluoromethane

C3H8

Pentafluoroethane

ETO

Methane

H2S

Dichlorotrifluoroethane

HCI

Chlorodifluoromethane

HCN

Chlorine Chlorine dioxide Carbon monoxide Carbon dioxide Propane Ethylene oxide Hydrogen sulfide Hydrogen chloride Hydrogen cyanide

N2 NH3 NO2 O2 O3 PH3 SO2 VOCs

Nitrogen Ammonia Nitrogen dioxide Oxygen Ozone Phosphine Sulfur dioxide Volatile organic compounds

Calibration Kits Cal kit for 58-103L cylinders (all products except SQN8x, AirScanTM IR-F9 and XCD) Sensepoint XCD combustilbe calibration kit Sensepoint XCD toxic calibration kit Sensepoint XCD RTD calibration kit - includes calibration cover, potentiometer, adjustment tool, flow housing, regulator and tubing (2106B2114, 02000-A-1645, 998-100-012, 998-100-003, 998-100-004) Sensepoint XCD RFD calibration kit - includes tubing, flow adaptor, regulator and carrying case (998-100-004, 00780-A-0035, 998-100-012 (1.5LPM), 998-100-003) AirScanTM IR-F9 calibration kit for use with 58/103L cylinders Demand flow regulator 58-103L cylinders, 0-3LPM for SQN8x Cal kit tubing 6 ft. 1/8 in. I.D. X 1/4 in. O.D. for SQN8x Bump test kit; includes balloon adapter and quad gas cylinder: H2S (40 ppm), CO (200 ppm), CH4 (2.5%), O2 (10%)

Order Number 1309K0002 XCDCOMBKIT XCDTOXKIT XCDRTDKIT
705CALKIT
11337-L9 M-700144 M-501062 TEST-1A

58L Calibration Gas Cylinders NH3 (25 ppm) NH3 (50 ppm) NH3 (100 ppm) NH3 (500 ppm) H2S (25 ppm) NO2 (5 ppm) Cl2 (5 ppm) NO (100 ppm) SO2 (5 ppm)

Balance N2 N2 Air Air N2 N2 N2 N2 N2

Liters Order Number 58 GFV213 58 2992-0015 58 M-501041 58 M-507546 58 M-501046 58 M-501054 58 M-501052 58 2992-0035 58 M-501055

103L Calibration Gas Cylinders Air N2 CH4 (1% / 20% LEL) (continued next page)

Balance Air N2 Air

Liters Order Number 103 M-501008 103 M-501011 103 M-500975

30

When placing an order, please reference the Order Number (not the Model Number) where applicable.

PG1100-9-NCL

Calibration Equipment

103L Calibration Gas Cylinders (cont'd) CH4 (25% LEL) CH4 (50% LEL) C3H8 (20% LEL) C3H8 (50% LEL) C2H4 (50% LEL) H2 (1% / 20% LEL) H2 (500 ppm) O2 (20%) O2 (20.9%) CO (200 ppm) CO2 (1,000 ppm) CO2 (2,000 ppm) CCl3F (R11) (500 ppm) CBrF3 (R13B1) (500 ppm) CHClF2 (R22) (500 ppm) CHCl2CF3 (R123) (500 ppm) CH3CHF2 (R125) (500 ppm) CF3-CH2F (R134A) (500 ppm) HFO-1234yf (500 ppm) HFO-1234yf (1000 ppm) HFO-1234yf (3000 ppm) R4310 (500 ppm) Blend of R125, R143A and R134A (R404A) (500 ppm) Blend of R32, R125 and R134A (R407C) (500 ppm) Blend of R32 and R125 (R410) (500 ppm) 50/50 Blend of R32 and R125 (R507) (500 ppm)

Balance Air Air Air Air Air Air Air N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2

Liters Order Number 103 998-012-001 103 998-022-001 103 M-507700 103 998-022-002 103 998-022-004 103 M-500976 103 1991-0159 103 M-500986 103 M-508161 103 M-500988 103 M-501010 103 M-500989 103 M-501012 103 M-511687 103 M-501005 103 M-501003 103 M-501004 103 M-504530 103 GFV543 103 GFV544 103 GFV545 103 0320-1024 103 M-509316 103 M-511688 103 M-511942 103 M-509317

103L Calibration Gas Cylinders: 100 ppm Refrigerant Calibration Gas; Designed for testing AirScanTM IR-F9, CARB 32 Units CHClF2 (R22) (100 ppm) CHCl2CF3 (R123) (100 ppm) CF3-CH2F (R134A) (100 ppm) Blend of R143A, R125 and R134A (R404A) (100 ppm) Blend of R32, R125 and R134A (R407C) (100 ppm) Blend of R32 and R125 (R410) (100 ppm) 50/50 Blend of R32 and R125 (R507) (100 ppm)

Balance N2 N2 N2 N2 N2 N2 N2

Liters Order Number 103 GFV541 103 M-500981 103 GFV542 103 GFV540 103 GFV539 103 GFV537 103 GFV538

PG1100-9-NCL

When placing an order, please reference the Order Number (not the Model Number) where applicable.

31

Honeywell Analytics Service
Honeywell Analytics' global standing for portable, fixed and low level toxic gas detection is backed up with a dedicated team of professionals that takes service and support to a whole new level. It's your choice... Whatever industry you're in, we have the levels of support that are right for your business. It's your business. It's your industry. And no matter whether you're managing personnel for confined space entry, or securing your plant against gas risks, the process has to keep moving. The alternative is downtime, or even total shutdown, and then the risks to your business are far greater. Honeywell provides service levels that make it easy to choose the right kind of support to keep your plant and people safe; to keep your business up and running - because that's our job! Choose from: Commissioning · Functional tests · Start-up · Staff training · Bump testing Contract Maintenance Service and Repair · On-site/workshop repair and calibration · Modification and conversion Calibration and Surveys · Instrument calibration equipment certified to national/regional
standards · Site surveys · Stock surveys

Honeywell Analytics Service contact information:
USA Service Workshop Headquarters 405 Barclay Blvd. Lincolnshire, IL 60069 USA Attn: Service Dept. Tel: 888-955-2585 (press 2) Fax: 847-572-1327 Email: haservice.workshop.us@honeywell.com

Canada Service Workshop Headquarters 3580 Rue Isabelle Unit 100 Brossard, Quebec, Canada J4Y 2R3
Tel: 1-800-563-2967 (select language + press 2) Email: haservice.canada@honeywell.com

32

When placing an order, please reference the Order Number (not the Model Number) where applicable.

PG1100-9-NCL

Honeywell Analytics Lines of Business

Commercial
Gas detection from standalone units to fully engineered, multi-point systems, all offering cost-effective regulatory compliance » Applications: parking structures,
chillers, mechanical rooms, office towers, commercial buildings, shopping centers, swimming pools, golf courses, schools and universities, laboratories

Industrial
Renowned Sieger and Manning gas detection systems with advanced electrochemical, infrared and open path sensing technologies » Applications: oil and gas, cold storage,
water/wastewater treatment, chemicals, engine rooms, plastics and fibers, agriculture, printing and light industrial

Portables
Single or multi-gas and other premium detectors with compact, lightweight designs ranging from simple alarm only units to advanced, fully configurable and serviceable instruments » Applications: underground utility
and electricity ducts, boiler rooms, post-fire sites, sewers, industrial plants, industrial hygiene, first responder teams, remote fleets

Find out more www.honeywellanalytics.com

USA Honeywell Analytics, Inc. 405 Barclay Blvd. Lincolnshire, IL 60069 USA Toll-free: 888-955-2585 (press 1) Tel: 847-955-8200 Fax: 847-955-8210 hasales.us@honeywell.com
USA Technical Services Tel: 888-955-2585 (press 2) haservice.workshop.us@honeywell.com
Canada 2840 2nd Ave SE Calgary, Alberta, Canada T2A 7X9
3580 Rue Isabelle Unit 100 Brossard, Quebec, Canada J4Y 2R3

High Tech/Government
A complete portfolio of gas and chemical detection instrumentation including infrared spectroscopy (MST) with no cross interference, to Chemcassette paperbased solutions (MDA Scientific) offering detection down to parts per billion » Applications: semiconductor
manufacturing and nanotechnology, aerospace propulsion and safety, specialty chemicals industry, research laboratories, emergency response

Technical Services
24/7 global network includes post-sales service and Systems Integration teams » Emergency call out, service
contracts, on/off-site repair, training and commissioning » Complete range of spares,
consumables and accessories

Toll-free: 1-800-563-2967 (select lang. + press 1) Tel: 847-955-8200 Fax: +1-450-619-2448 hasales.canada@honeywell.com
Canada Technical Services Tel: 1-800-563-2967 (select lang. + press 2) haservice.canada@honeywell.com
www.honeywell.com

Latin & South America Marginal da Rodovia dos Bandeirantes, 100 Distrito Industrial Jundiaí, São Paulo ­ Brazil ZIP: 13213-008 Tel: +55 11 3309 1030 Fax: +55 11 3309 1005 ha.latinamerica@honeywell.com

Europe, Middle East, Africa Life Safety Distribution AG Javastrasse 2 8604 Hegnau Switzerland Tel: +41 (0) 44 943 4380 Fax: +41 (0) 44 943 4398 gasdetection@honeywell.com

Asia Pacific Honeywell Analytics, Asia Pacific #701 Kolon Science Valley (1) 43 Digital-Ro 34-Gil, Guro-Gu Seoul 152-729 Korea Tel: +82 2 6909 0300 Fax:+82 2 6909 0329 analytics.ap@honeywell.com

Please Note: While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract.
PG1100-9-NCL © 2015 Honeywell Analytics


Adobe PDF Library 11.0 Adobe InDesign CC 2014 (Windows)