SC18MLX MBP Compressor R404A/R507 220V 50Hz

PDF preview unavailable. Download the PDF instead.

AI376135611517en-010101
SC18MLX MBP Compressor R404A/R507 220-240V 50Hz

General Code number Approvals Compressors on pallet
Application Application Frequency Evaporating temperature Voltage range Max. condensing temperature continuous (short) Max. winding temperature continuous (short)
Cooling requirements Frequency Application 32°C 38°C 43°C Remarks on application:

104L2139 EN 60335-2-34
80

MBP

Hz

50

60

°C -23.3 to 7.2

­

V 198 - 254

­

°C 50 (60)

­

°C 125 (135)

­

Hz

50

60

LBP MBP HBP LBP MBP HBP

­ F2 ­ ­ ­ ­ ­ F2 ­ ­ ­ ­ ­­­­­­

S = Static cooling normally sufficient O = Oil cooling F1 = Fan cooling 1.5 m/s
(compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary SG = Suction gas cooling normally sufficent ­ = not applicable in this area

Motor Motor type LRA (rated after 4 sec. UL984), HST | LST Cut in Current, HST | LST Resistance, main | start winding (25°C)

CSR

A

23.6

­

A

23.6

­



3.4

14.4

Design Displacement Oil quantity (type) Maximum refrigerant charge Free gas volume in compressor Weight without electrical equipment

cm3

17.68

cm3

600 (polyolester)

g

1300

cm3

1460

kg

14.0

Dimensions Height
Suction connector Process connector Discharge connector Oil cooler connector Connector tolerance Remarks:

mm A

219

B

213

B1

193

B2

110

location/I.D. mm | angle C

10.2 | 37°

material | comment Cu-plated steel | Al cap

location/I.D. mm | angle D

6.2 | 37°

material | comment Cu-plated steel | Al cap

location/I.D. mm | angle E

6.2 | 37°

material | comment Cu-plated steel | Al cap

location/I.D. mm | angle F

­

material | comment

­

I.D. mm

±0.09

Dec 2011

Manufactured by Secop for Danfoss - DEHC.ED.400.J3.02 / 520N0256

1/2

EN 12900 Household (CECOMAF)

220V, 50Hz, fan cooling F2

Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0

5 7.2 10 15 20

Capacity in W

831 968 1210 1497 1712 1832 2220 2665 2880

Power cons. in W

676 722 790 860 907 931 1004 1080 1114

Current cons. in A

3.57 3.76 4.07 4.40 4.63 4.75 5.12 5.51 5.69

COP in W/W

1.23 1.34 1.53 1.74 1.89 1.97 2.21 2.47 2.59

ASHRAE MBP

220V, 50Hz, fan cooling F2

Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0

5 7.2 10 15 20

Capacity in W

762 887 1111 1380 1584 1698 2072 2507 2720

Power cons. in W

703 757 838 920 975 1003 1087 1173 1212

Current cons. in A

3.70 3.92 4.27 4.65 4.91 5.04 5.46 5.89 6.09

COP in W/W

1.08 1.17 1.33 1.50 1.62 1.69 1.91 2.14 2.24

Accessories for SC18MLX

Figure

Sarting device

470 mm cable length

550 mm cable length a3
650 mm cable length

1000 mm cable length

Cover

b

Starting relay

6.3 mm spade connectors a2

Start. capacitor 80 µF 6.3 mm spade connectors c

Run capacitor 10 µF 6.3 mm spade connectors e

Cord relief

d

Code number 117-7012 117-7027 117-7046 117-7040 103N2009
Components of starting device
103N1004

Test conditions

EN 12900/CECOMAF

Condensing temperature

45°C

Ambient temperature

32°C

Suction gas temperature

32°C

Liquid temperature

no subcooling

ASHRAE MBP 54.4°C 35°C 35°C 46.1°C

Mounting accessories Bolt joint for one comp. Bolt joint in quantities Snap-on in quantities

Ø: 16 mm Ø: 16 mm Ø: 16 mm

Code number 118-1917 118-1918 118-1919

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

2/2

Manufactured by Secop for Danfoss - DEHC.ED.400.J3.02 / 520N0256

Dec 2011


Danfoss A/S