Saffire LX-D & Saffire Evo Deadbolt Installation Guide

WARNING 1. Please read and follow all directions carefully.
2. This lock is not designed to be used on emergency exit doors. 3. Carefully inspect glass, door frame, door, etc. to ensure the recommended procedure will not cause damage.
dormakaba standard warranty does not cover damages caused by installation. 4. Wear safety glasses when making the holes. 5. All the following operations and testing of the lock are to be done with door open.

TOOLS REQUIRED · Safety glasses · 1/2" (13mm) Chisel · 1/8" (3mm) Drill Bit · 5/32" (4mm) Drill Bit · 1" (25mm) Drill Bit or Hole Saw · 2 1/8" (54mm) Drill Bit or Hole
Saw · Drill · Awl or Center Punch · Screwdriver, 1/8" Slotted · Philips Screwdriver #2 · Adjustable Square · Tape Measure · Screw driver Torx T10

1A - INSTALL STRIKE ON WOOD FRAME For maximum security, install reinforcing plate.
Install long screws in door stop side

1B - INSTALL STRIKE ON STEEL FRAME
Door stop

1C - DOOR PREPARATION
A

A = Backset = 2.3/4"(70mm) or 2 3/8" (60mm)

1" (25mm)

1. Determine which template fits your Saffire LX-D lock installation, either 2 3/8" (60mm) or 2 3/4" (70mm) backset.
2. Place appropriate template onto door and mark holes. 3. Drill holes as per dimensions on the template. The 1" (25 mm) hole
shall be on the center line of door thickness. 4. Mortise door edge for dead bolt face plate. 5. Drill 2 1/8" from both sides of the door to prevent unsightly damage.

2 1/8" (54mm) Hole saw

2. ADJUST BACKSET OF DEADBOLT 1

3. INSTALL DEADBOLT IN DOOR 2

3
DO NOT REMOVE TAPE TAPE IS REQUIRED FOR BACK SET ADJUSTMENT
DEADBOLT IS PRE-SET AT 2 ¾" (70mm) BACKSET. PROCEED AS SHOWN TO CHANGE TO 2 " (60mm) BACKSET, IF REQUIRED.

SLOT AT THE BOTTOM

DO NOT REMOVE TAPE
2X 14 OR 2X 13 FOR STEEL DOOR

PK3705 - Rev 8

ITEM NO.

QTY. DESCRIPTION

1

1 FRONT LOCK HOUSING ASSEMBLY

2

1 GASKET FRONT LOCK HOUSING

3

1 TAIL PIECE

4

1 INSIDE TRIM ASSEMBLY

5

1 INSIDE TRIM COVER ASSEMBLY

6

1 DEADBOLT

7

1 STRIKER PLATE

8

1 DUST BOX

9

1 REINFORCING PLATE

10

2 PHILLIPS #2, FLAT HEAD WOOD SCREW 8 X 1" LG

11

2 PHILLIPS #2, FLAT HEAD WOOD SCREW 8 X 3" LG

12

2 PHILLIPS #2, FLAT HEAD SCREW 8-32 X 7/32" LG

13

4 PHILLIPS #2, FLAT HEAD SCREW 8-32 X 1/2" LG

14

2 PHILLIPS #2, FLAT HEAD WOOD SCREW 8 X 1" LG

15

1 PHILLIPE #2, TRUSS HEAD 6-32 X 5/16" LG

16

3 PHILLIPS #2, PAN HEAD SCREW 10-24 X 1-1/4" LG

17

1 COMMUNICATION HARNESS (OPTIONAL)

18

1 POWER CABLE

19

3 AA BATTERY

ITEM NO.

QTY. DESCRIPTION

20 1 FIRE PLATE 21 1 BASE PLATE 22 1 COVER PLATE 23 1 LOCATING POST 24 3 PHILLIPS #2 FLAT HEAD SCREW 10-24 X 1.500" LG 25 3 PHILLIPS #2 PAN HEAD SCREW 6-32 X 5/16" LG

PART LIST & LOCK DIAGRAM

FOR DOOR THICKNESS BETWEEN 2-1/4" AND 2-1/2" PLEASE ORDER HARDWARE KIT 062-515846.

HORIZONTAL MOUNTING OPTION INSIDE TRIM

1 2 3

4 19

23
20 24

21 22

12
9 8

18

17

14

6

15

13 13

16

7 10

5

11

1-877-468-3555 www.dormakaba.us

25 Please continue on next page.

4. ADJUST LOCK HANDING ON OUTSIDE HOUSING ASSEMBLY 1. HOLD INNER CAM IN PLACE, INNER CAM GROOVE ORIENTED AT 12 O'CLOCK. 2. FOR RH LOCK, ROTATE OUTER CAM COUNTERCLOCKWISE UNTIL OUTER CAM GROOVE IS ORIENTED AT 6 O'CLOCK. 3. FOR LH LOCK, ROTATE OUTER CAM CLOCKWISE UNTIL OUTER CAM GROOVE IS ORIENTED AT 12 O'CLOCK.

LEFT HAND (LH) OUTER CAM

GROOVE AT 12 O'CLOCK

RIGHT HAND (RH)

INNER CAM

2- ROTATE TO CHANGE FROM LH TO RH.

GROOVE AT 6 O'CLOCK

5. ASSEMBLE TAIL PIECE

1- HOLD TO PREVENT ROTATION.
6. REMOVE INSIDE COVER

7. ASSEMBLE OUTSIDE HOUSING

STEP 1
TAIL PIECE SHALL BE "SNAP" IN PLACE WITH WIRE RING OPENING ROTATED AT 12 O'CLOCK.

STEP 2

REMOVE TAPE

WARNING ALIGN STUD AND TAIL PIECE GENTLY INTO DEAD BOLT TAIL PIECE MUST BE BELOW DEADBOLT CENTER LINE

PK3705 - Rev 8

8A - INSTALL INSIDE TRIM ASSEMBLY (VERTICAL MOUNTING ONLY) - FOR HORIZONTAL MOUNTING SEE 8B - SHEET 3 THEN PROCEED WITH SECTION 9.
1. INSTALL INSIDE TRIM ON DOOR AS SHOWN BELOW, RUNNING CABLES THROUGH INSIDE TRIM BACKPLATE LOWER SLOT. CABLE SHALL BE PULL GENTLY TO ACCUMULATE ALL EXCESS WITHIN INSIDE TRIM.
2. INSTALL MOUNTING SCREW, 3X. 3. BEFORE TIGHTENING THE SCREWS, DEADBOLT FUNCTIONALITY SHALL BE VALIDATED BY ROTATING TAIL PIECE FROM
INSIDE. DEADBOLT SHALL MOVE SMOOTHLY. 4. ALL SCREWS SHALL BE TIGHTENED PROPERLY. 5. INSTALL BATTERIES AFTER TIGHTENING ALL SCREWS AND CONNECTING WIRING V1 & V2 AND W1 & W2 IF APPLICABLE.
6. AFTER CONNECTION, CABLES SHALL BE ROUTED AROUND THE CLIPS

CONNECT V1 TO V2 (POWER)

CONNECT W1 TO W2 (COMMUNICATION IF APPLICABLE)

MAKE SURE THE HARNESS WILL NOT COME INTO CONTACT WITH THE SPINDLE.

9. INSIDE COVER INSTALLATION

KEEP HARNESS INSIDE TAB TO AVOID PINCHING WITH COVER

METHOD 1: FOR THIN DOOR, 1.375" TO 1.50 PLEASE FOLLOW STEP 1, 2A, 3A, 4 & 5. METHOD 2 (FOR TAIL PIECE WITH CHAMFER ONLY): FOR NORMAL DOOR 1.75" AND THICKER PLEASE FOLLOW STEP 2B, 3B, 4 & 5. FOR DOOR FROM 1.5" TO 1.75" PLEASE USE THE MOST CONVENIENT METHOD, 1 OR 2.

CHAMFER

STEP 1 STEP 1

KNOB

LH INSTALLATION

RH INSTALLATION

STEP 1: ENGAGE TAIL PIECE

STEP 2A: MOVE THE COVER UPWARD. TAIL PIECE STEP 2B: ENGAGE COVER'S TAB IN BACK

MUST REMAIN ENGAGED IN TURN KNOB.

PLATE'S HOOK. LIFT COVER AS REQUIRED.

STEP 3A : ENGAGE COVER'S TAB WITH BACK PLATE HOOK.

STEP 3B : LOWER COVER AND ROTATE AS SHOWN. TAIL PIECE WITH CHANFER SHALL ENGAGE IN RELATED SLOT AUTOMATICALLY.

STEP 3A

STEP 2B

STEP 3B

TAIL PIECE WITH CHAMFER USE METHOD 1 OR 2
TAIL PIECE WITHOUT CHAMFER USE METHOD 1 ONLY TAIL PIECE SHALL BE IN VERTICAL POSITION & KNOB IN HORIZONTAL POSITION.
STEP 4: CLOSE COVER'S BOTTOM. STEP 5: INSTALL SCREWS.
STEP 4

STEP 2A
GAP KEEP CLEARANCE TO MIN.
TO FACILITATE INSTAL. OF COVER

STEP 5
STEP 6: PROTECTIVE PLASTIC FILM SHALL BE REMOVED FROM THE COVER, BOTH SIDE.

8B - INSTALL INSIDE TRIM ASSEMBLY HORIZONTAL MOUNTING OPTION (IF APPLICABLE)
1. BEFORE TIGHTENING THE SCREWS VERIFY FUNCTIONALITY BY EXTRACTING AND RETRACTING THE DEADBOLT. DEADBOLT SHALL MOVE SMOOTHLY.
2. ALL SCREWS SHALL BE TIGHTENED PROPERLY. 3. CONNECT BATTERIES AFTER TIGHTENING ALL SCREWS AND WIRING W1 & W2.

COVER PLATE AND INSIDE TRIM ASSEMBLY SHALL BE INSTALLED AS SHOWN WITH 3X SCREWS, ITEM 25.

LH MOUNTING

RH MOUNTING

1. HARNESS SHALL BE PULLED GENTLY THROUGH INSIDE TRIM'S BACKPLATE TO ACCUMULATE ALL EXCESS CABLES WITHIN THE INSIDE TRIM.

1. HARNESS SHALL BE PULLED GENTLY THROUGH INSIDE TRIM'S BACKPLATE TO ACCUMULATE ALL EXCESS CABLES WITHIN THE INSIDE TRIM.

25
CONNECT V1 TO V2 (POWER)

CONNECT W1 TO W2 (COMMUNICATION IF APPLICABLE)
POWER AND COMMUNICATION CABLES SHALL BE CONNECTED AND ROUTED AS SHOWN ON SHEET 2.

9B - INSTALL INSIDE TRIM COVER SEE INSTALLATION DETAIL ON SHEET 2.

LOCATING POST AND MOUNTING SCREWS SHALL BE INSTALLED AS SHOWN. LEFT MOUNTING SHOWN. COVER REMOVED FOR CLARITY

2 1

PK3705 - Rev 8

INTENTIONALLY LEFT BLANK.

PK3705 - Rev 8

ISED non-interference disclaimer This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
This equipment complies with ISED RSS-102 radiation exposure limits set forth far an uncontrolled environment. This transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement."
Cet équipement est conforme avec ISED RSS-102 des limites d'exposition aux rayonnements définies pour un environnement non contrôlé. Cet émetteur doit être installé à au moins 20 cm de toute personne et ne doit pas être colocalisé ou fonctionner en association avec une autre antenne ou émetteur.
FCC Compliance Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
· Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. · Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
RF Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be colocated or operating in conjunction with any other antenna or transmitter. To avoid the possibility of exceeding the FCC radio frequency exposure limits, this equipment should be installed and operated with minimum distance 20 cm between the antenna and your body during normal operation. Users must follow the specific operating instructions for satisfying RF exposure compliance.

REV 6

ECN

DESCRIPTION

REVISIONS

CN03611

TITLE WAS: Saffire LX-D & Saffire Evo LX-D InstallationGuide for door thickness 1 3/8" to 2 1/8", BOM ITEM 16 WAS PHILLIPS, 10-24 X 1-1/4" PAN HEAD SCREW; SHEET 1 ADRESSE REMOVED

FAIT PAR/ DONE BY

VÉR. PAR/ VER. BY

DATE

AC

CD

2022-12-06

SHEET 1: TITLE WAS Saffire LX Deadbolt & Saffire Evo LX Deadbolt Installation Guide for door thickness 1 3/8" to 2 1/8"; ITEM 17 WAS MESSENGER

7

CN03645

CABLE, BALLOON 23 ADDED; SHEET 2 SECTION 2A WAS 2, SECTION 3A WAS 3; SECTION 2B & 3B WITH RELATED VIEW ADDED; SHEET 2 SECTION 5: 12 O'CLOCK WAS 6 O'CLOCK, HARNESS ROUTING REVISED; SHEET 3: SECTION 8 HARNESS WAS CABLE 2X PLACES; BALLOON

AC

25 ADDED, ROUTING VIEW REMOVE & RELATED NOTE REVISED, SECTION 9B ADDED

8

CN04398

SHEET 4 ADDED; INDUSTRY CANADA AND FCC NOTE TRANSFER TO SHEET 4; SHEET 3: VIEW SPACED OUT; SHEET 4: INDUSTRY CANADA & FCC NOTE REVISED AS PER TUV REQUEST

AC

CD

2023-03-13

CD

2023-06-29

REVISIONDTOABNLOETFPORRINETNTGHINISESEEREINTG ONLY

2023-07-03 1:56:51 PM

This document containing drawings and information derived therefrom or thereon is confidential and proprietary to dormakaba Canada inc. This document is submitted in confidence and its contents may not be disclosed, reproduced, or revealed in any manner without prior written consent from dormakaba Canada inc. This document will be returned to dormakaba Canada inc. upon demand.
Ce document contenant des dessins et des informations dérivés de celui-ci est confidentiel et la propriété de dormakaba Canada inc. Ce document est soumis à titre confidentiel et son contenu ne peut être divulgué, reproduit ou révélé de quelque manière que ce soit sans le consentement écrit préalable de dormakaba Canada inc. Ce document sera retourné a dormakaba Canada inc. sur demande.

DIMENSIONS = MILLIMETER / MILLIMÈTRE
3D FILE GOVERNS ALL UNSPECIFIED DIMENSIONS & GENERAL

DRAWN BY / DESSINÉ PAR:
A.CHIQUETTE

TOLERANCES APPLY / LES DIMENSIONS NON SPÉCIFIÉES SONT DÉFINIES APPROVED BY / APPROUVÉ PAR:

PAR LE FICHIER 3D ET LES TOLÉRANCES GÉNÉRALES S'APPLIQUENT GENERAL TOLERANCE, UNLESS OTHERWISE SPECIFIED TOLÉRANCES GÉNÉRALES, SAUF SI SPÉCIFIÉ AUTREMENT

C.DOUCET
MATERIAL / MATÉRIEL

X 0.25 X.X 0.25 X.XX 0.25 HOLE / TROU

THREAD CLASS / FILET SAE: 2A-2B ISO: 6g / 6H
ANGLE: 1°

FINISH / FINI
3.2

N/A
FINISH / FINI

: +0.13/-0.05 CHAMFER /CHANFREIN:

5° N/A

AS PER / SELON : ASME Y14.5M-2009

YYYY-MM-DD
2018-08-20
YYYY-MM-DD
2018-08-21 TITLE / TITRE

DWG NO / NO. DESSIN
PK3705
PART NO / NO. DE PIÈCE
PK3705

dormakaba Canada Inc. 7301, boul. Décarie Montréal, QC, Canada, H4P 2G7
REVISION
8
SHEET / FEUIL.
1 / 5

