STI-6405
STI EXIT STOPPER®

To Stop Unauthorized Exits/Entries Through Emergency Exit Doors
Here is a highly effective way to alert you to any unauthorized exits or entries through any emergency exit door. By doing so, it can serve as an inexpensive security device and help stop theft.

How It Works
If the protected door is opened, the electronic Exit Stopper emits an ear piercing alarm for 30 seconds, 3 minutes or continuously (as preset by the user). A key operated override will silence the alarm and allow authorized exits. Exit Stopper "Always Active" allows the keyholder to reset the alarm, but does not allow the alarm to be turned off. Exit Stopper is fitted with a 9 VDC alkaline battery. It is available in red or green for almost any type of door, mounting or installation, including remote placement of the alarm.

STI-6400

STI-6405

STI-6406

Features

· Upon installation, user can select on site whether to use as an alarm or annunciator.
· May be mounted on top, right, left or next to almost any door.

· Unit is completely self-contained.
· STI-6403 allows for remote horn to be located 150 feet from the door it is protecting - 18 gauge wire not included or electrically supervised.

· May be set for piercing 105 dB warning horn or · STI-6404 provides protection for double doors

softer 95 dB.

and has remote horn capabilities.

· In exit alarm mode, alarm can be set to sound · STI-6405 allows keyholder to reset the alarm.

for 30 seconds, 3 minutes or indefinitely (unless disarmed with key supplied or until battery is drained).
· In annunciator mode, it announces door entry with a set of 10 beeps.
· May be programmed for 15 second entry delay or immediate alarm.

· STI-6406 can be operated from both sides of the exit/entry door without using alarm delays.
· Highly visible "stop sign" design acts as a deterrent.
· Exit delay allows unit to arm following authorized exits.
· Available in red or green.

· STI-6402 provides protection for double door applications with two sets of reed contacts.

· Lifetime guarantee against breakage of polycarbonate with normal use (one year on electronic components).

· Detects both unauthorized exits and entries.

· Easy to install...much less expensive than heavy

· Recommended operational temperature range is

horizontal bar type units...and practical for all

32°F to 120°F (0°C to 49°C).

emergency doors.

Safety Technology International, Inc.
2306 Airport Road · Waterford, Michigan 48327-1209 Phone: 248-673-9898 · Fax: 248-673-1246 · Toll Free: 800-888-4784 · E-mail: info@sti-usa.com · Web: www.sti-usa.com
Europe Branch Office · Unit 49G Pipers Road · Park Farm Industrial Estate · Redditch · Worcestershire · B98 0HU · England Tel: 44 (0) 1527 520 999 · Fax: 44 (0) 1527 501 999 · Freephone: 0800 085 1678 (UK only) · E-mail: info@sti-europe.com · Web: www.sti-europe.com

STI EXIT STOPPER®
Dimensions and Technical Information

Models Available

STI-6400 Exit Stopper multifunction door alarm FEATURE

JP2 JP3 JP4 JP5 JP7

STI-6402 Exit Stopper multifunction door alarm Volume- (105 dB) at 1 foot ON*

STOP for double door installation
STI-6403 Exit Stopper multifunction door alarm Volume- (95 dB) at 1 foot

OFF

with remote horn

Duration- 30 Second Alarm

OFF*

OFF*

STI-6404 Exit Stopper for double door with

Duration- 180 Second Alarm

OFF ON

STI-6405
STI-6406 STI-6453

remote horn Exit Stopper multifunction door alarm with "always active" feature Exit Stopper with dual access control Replacement siren alarm

Duration- Continuous Alarm Duration- Annunciator Mode Trip- Immediate Trip- 15 Second Delay

ON OFF

ON

ON

OFF*

ON

SUB-6403 Remote horn to use in conjunction

Arming- Immediate

ON*

06402

with all above exit alarm models or to replace remote horn in STI-6403 Magnet and reed switch with spacers

Arming- 15 Second Delay
*Factory Settings

OFF
SPECIFICATIONS

NOTE:

In moderate to high noise, a sound level check should be done to verify audibility in all areas where unit is needed to be heard.
End user must verify the alarm and battery every six months and replace battery annually or as required.

Housing

1/8 in. Polycarbonate

Power Source STV9ODVCPDWC iArelkdaline or 12-24

ALARM VOLUME SWITCH (ON) JP2 TRIP DELAY SWITCH (OFF) JP5

ALARM DURATION SWITCH

(OFF) JP4 (OFF) JP3

TERMINAL BLOCK

Warning Horn 95 dB - low

at 1 foot

105 dB - high

Relay Contacts Dimensions

Form C Dry 0-30 Volts AC/DC, 1 Amp
STOP
5.375 in. x 5.375 in. x 2 in. 137mm x 137mm x 51mm

Standby Current 10 uA

(FACTORY DEFAULT SETTINGS)

Alarm Current 200 mA

ARMING SWITCH (ON) JP7

Recommended 32°F to 120°F

Operating

(0°C to 49°C)

Temperature

Printed in U.S.A. © 1987, `90, `92, `95, `97, 2000, `02, `04, `05, `06, `07 Safety Technology Int'l.

STOP
EMERGENCY EXIT ONLY

FLANGES

ALARM SOUNDS WHEN DOOR IS OPENED

ON

OFF

SLOTS

TERMINAL STRIP 9 VOLT BATTERY

STOP

COVER 19014 MOUNTING SCREWS (4) PROVIDED

BASE

19011 TAMPERPROOF SCREW (1) PROVIDED
19016 TAMPER WRENCH (1) PROVIDED

STI-6400 Spec. 07/07

