02-661blot guide FINAL

Diana Kollanyi

A Guide to Transfer and Detection

21 ott 2022 — See Chapter 2 and the instruction manual for suggested run times with various buffers. 14. Upon completion of the run, remove the cathode assembly and ...

Fast Semi Dry Transfer | Keyword Rankings

PDF preview unavailable. Download the PDF instead.

biorad-pbguide
A Guide to Transfer and Detection
Third Edition

About This Manual
This reference manual provides information on the fundamentals of protein transfer and detection chemistries. It is also a guide to the methods, equipment, and reagents used in protein blotting experiments, and offers troubleshooting tips and technical advice.
As a researcher using the blotting technique, you know that each research objective, experimental approach, and protein sample can be different. Your equipment, sample, antibody, and detection chemistries all can impact your results. The goal of this manual is to provide you with a broad understanding of the variables you face when blotting, and how best to work with each of them to achieve the optimal results.
A History of Leadership and Quality
A pioneer in the design and manufacture of western blotting apparatus with 30 years of experience, Bio-Rad is considered the industry leader in providing high-quality, durable, and powerful blotting equipment.
Bio-Rad offers superior products and expert technical service. Our goal is to support your research with the necessary tools and materials to optimize the analysis of complex protein samples.
Meeting Your Blotting Needs
Turn to Bio-Rad for: · Gel-blotting equipment for an array of gel sizes · Microfiltration devices · Multiple-sample screening devices · Membranes for every binding requirement · Protein standards · Blotting buffers, reagents, and background removal kits · Colorimetric and chemiluminescent detection reagents · Total protein stains · Secondary antibodies and antibody conjugates
For detailed protocols on the use of any of the products mentioned in this guide, please refer to their instruction manuals, available in Adobe Acrobat (PDF) format at discover.bio-rad.com

Protein Blotting Guide

1

Table of Contents

Protein Blotting

Introduction to Protein Blotting

7

Chapter 1 Transfer
Transfer Methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Electrophoretic Transfer The Principle of Electrophoretic Transfer Types of Electrophoretic Transfer Microfiltration (Dot-Blotting) . . . . . . . . . . . . . . . . . . . .11
Blotting Systems and Power Supplies . . . . . . . . . . . .12 Transfer Apparatus . . . . . . . . . . . . . . . . . . . . . . . . . .12 Tank Blotting Apparatus Semi-Dry Blotting Apparatus Microfiltration Apparatus Power Supplies for Electrophoretic Transfers . . . . . . .15

Power Conditions for Electrophoretic Transfers . . . . .21 Useful Equations . . . . . . . . . . . . . . . . . . . . . . . . . . .22 Joule Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 Other Factors Affecting Transfer . . . . . . . . . . . . . . . .22 Relationship Between Power Settings and Transfer Times . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 High-Intensity Field Transfers Standard Field Transfers Selecting Power Supply Settings . . . . . . . . . . . . . . . .22 Transfers Under Constant Voltage Transfers Under Constant Current Transfers Under Constant Power
General Guidelines for Transfer Buffers and Transfer Conditions . . . . . . . . . . . . . . . . . . . . . . .24
Chapter 3 Performing the Transfer

Chapter 2 Membranes, Buffers, and Power Conditions
Membrane Selection . . . . . . . . . . . . . . . . . . . . . . . . . .17 Nitrocellulose and Supported Nitrocellulose . . . . . . . .17 Polyvinylidene Difluoride (PVDF) Membrane . . . . . . . .18

Electrophoretic Transfer . . . . . . . . . . . . . . . . . . . . . . .25
Performing a Tank Transfer . . . . . . . . . . . . . . . . . . . . .25 Preparing the Transfer Buffer, Gels, and Tank Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 Assembling the Gel and Membrane Sandwich . . . . . .26 Performing the Transfer . . . . . . . . . . . . . . . . . . . . . .27

Blotting Filter Paper . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Membrane/Filter Paper Sandwiches . . . . . . . . . . . . . .19
Transfer Buffer Selection . . . . . . . . . . . . . . . . . . . . . . .19 General Recommendations . . . . . . . . . . . . . . . . . . . .20 A Note About SDS and Alcohol Towbin and Bjerrum and Schafer-Nielsen Buffers (Tris/Glycine Buffers) . . . . . . . . . . . . . . . . . . . . . . . . .20 CAPS Buffer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 Discontinuous Tris-CAPS Buffer System (Semi-Dry Transfers) . . . . . . . . . . . . . . . . . . . . . . . . .21 Dunn Carbonate Buffer . . . . . . . . . . . . . . . . . . . . . . .21 Alternative Buffer Conditions . . . . . . . . . . . . . . . . . . .21

Performing a Semi-Dry Transfer . . . . . . . . . . . . . . . . .27 Preparing the Transfer Buffer and Gels . . . . . . . . . . .27 Assembling the Gel and Membrane Sandwich . . . . . .28 Performing the Transfer . . . . . . . . . . . . . . . . . . . . . . .28
Microfiltration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 Application of the Vacuum . . . . . . . . . . . . . . . . . . . .28 Proper Drainage . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 Flow Valve -- Extended Incubations . . . . . . . . . . . . .29 Flow Valve -- Gentle Vacuum . . . . . . . . . . . . . . . . . .29 Filtering or Centrifugation of Samples . . . . . . . . . . . .29 Air Bubbles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 Membrane Removal . . . . . . . . . . . . . . . . . . . . . . . . .29

Protein Blotting Guide

3

Table of Contents

Protein Blotting

Chapter 4 Detection
Detection Methods . . . . . . . . . . . . . . . . . . . . . . . . . . .31
Protein Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . .32 Prestained Standards for Western Blotting . . . . . . . . .33 Recombinant Prestained Standards Natural Prestained SDS-PAGE Standards Unstained Standards for Western Blotting . . . . . . . . .35
Total Protein Staining . . . . . . . . . . . . . . . . . . . . . . . . .36 Anionic Dyes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37 Colloidal Gold . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37 Biotinylation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38 Fluorescence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38

Gel Cassette Pattern Transferred to Blot
Poor Binding to the Membrane -- Nitrocellulose
Poor Binding to the Membrane -- PVDF
Blotting Standards . . . . . . . . . . . . . . . . . . . . . . . . . .55
Missing Bands
Molecular Weight Assignments for Natural (Nonrecombinant) Prestained Standards Differ From Lot to Lot
A Protein's Molecular Weight Differs From Expected Molecular Weight
Variation in Mobility Between Recombinant and Natural Prestained Standards of the Same Molecular Weight
Microfiltration Blotting . . . . . . . . . . . . . . . . . . . . . . . .56
Leakage or Cross-Well Contamination
Uneven Filtration or No Filtration
Halos Around the Wells

Immunological Detection Systems . . . . . . . . . . . . . . .38 Blocking Reagents . . . . . . . . . . . . . . . . . . . . . . . . . .39 Antibody Incubations . . . . . . . . . . . . . . . . . . . . . . . .39 Primary Antibodies Species-Specific Secondary Antibodies Antibody-Specific Ligands Washes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41 Detection Methods . . . . . . . . . . . . . . . . . . . . . . . . . .41 Colorimetric Detection Chemiluminescent Detection Other Detection Methods Imaging -- Documentation and Analysis Methods . . .48 Luminescent Detection Fluorescent, Chemifluorescent, and Colorimetric Detection Autoradiography Screening Apparatus . . . . . . . . . . . . . . . . . . . . . . . .50
Chapter 5 Troubleshooting
Transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 Electrophoretic Transfer . . . . . . . . . . . . . . . . . . . . . .52 Poor Electrophoretic Transfer Swirls or Missing Patterns; Diffuse Transfers

Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57 Immunological Detection . . . . . . . . . . . . . . . . . . . . .57 Overall High Background Nonspecific Reactions Between Bound Proteins and Probes No Reaction or Weak Signal Tests for Monitoring Reagent Activity Multiscreen Apparatus . . . . . . . . . . . . . . . . . . . . . . .59 Leakage or Cross-Well Contamination Bubbles Trapped Within the Channels Halos Around the Wells Total Protein Detection . . . . . . . . . . . . . . . . . . . . . . .59 Colloidal Gold Total Protein Stain -- High Background Colloidal Gold Total Protein Stain -- Low Sensitivity Biotin-BlotTM Total Protein Detection -- High Background Biotin-Blot Total Protein Detection -- No Reaction or Weak Color Development Anionic Dyes -- High Background Anionic Dyes -- Low Sensitivity

4

Protein Blotting Guide

Appendices
Transfer Buffer Formulations . . . . . . . . . . . . . . . . . . . .62
Detection Buffer Formulations . . . . . . . . . . . . . . . . . .63 General Detection Buffers . . . . . . . . . . . . . . . . . . . . .63 Total Protein Staining Buffers and Solutions . . . . . . . .64 Substrate Buffers and Solutions . . . . . . . . . . . . . . . .64
Assay Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . .66 Immun-Blot® Assay . . . . . . . . . . . . . . . . . . . . . . . . .66 Total Protein Detection Procedures . . . . . . . . . . . . . .67
Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72
Trademarks and Legal Notices . . . . . . . . . . . . . . . . . .73
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . .74

Table of Contents

Protein Blotting

Protein Blotting Guide

5

Introduction

Protein Blotting

Overview of protein blotting methods. Dark colors indicate the transfer phase, light colors indicate the detection phase.

Proteins Electrophoretically Separated in a Gel
Electrophoretic Transfer

Protein Sample in Free Solution

Sample Matrix

Microfiltration (Dot-Blotting)

Transfer Method

Membranes Reagents
Power Conditions

Conditions

Immunological Detection

Total Protein Detection

Imaging

Detection/Identification

6

Protein Blotting Guide

Introduction

Protein Blotting

Introduction to Protein Blotting
Protein blotting, the transfer of proteins to solid-phase membrane supports, has become a powerful and popular technique for the visualization and identification of proteins. When bound to membranes, proteins are readily accessible for immunological or biochemical analyses, quantitative staining, or demonstration of protein-protein or protein-ligand interactions.
Protein blotting involves two major phases: transfer and detection (see overview opposite).
Transfer
The transfer step involves moving the proteins from a solution or gel and immobilizing them on a synthetic membrane support (blot). Transfer may be performed by direct application or dot-blotting of proteins that are in solution, or by electrophoretic transfer of proteins from a gel to a membrane. In performing a protein transfer, the researcher must choose the appropriate method, apparatus, membrane, buffer, and transfer conditions.
Detection
Detection entails probing the membrane with either a total protein stain or primary antibodies specific to the protein(s) of interest and subsequent visualization of the labeled proteins. Detection involves a number of steps and the selection of the appropriate method, reagents, and imaging equipment.
The most commonly used protein blotting technique, western blotting (immunoblotting), was developed as a result of the need to probe for proteins that were inaccessible to antibodies while in polyacrylamide gels. Western blotting procedures involve the transfer of proteins that have been separated by gel electrophoresis onto a membrane, followed by immunological detection of these proteins. Western blotting combines the resolution of gel electrophoresis with the specificity of immunoassays, allowing individual proteins in mixtures to be identified and analyzed. Since the development of immunoblotting techniques, other probing and detection techniques have been developed for functional protein characterization.
Many applications and methods for protein blotting have been previously reviewed (Beisiegel 1986, Bers and Garfin 1985, Carr and Scott 1992, Crisp and Dunn 1994, Dunn 1994, 1999, Egger and Bienz 1994, Garfin and Bers 1989, Gershoni 1985, 1987, 1988, Gershoni and Palade 1983, Gooderham 1984, Harper, et al. 1990, Kurien and Scofield 2003, Tovey and Baldo 1987, Wisdom 1994). This manual summarizes the most commonly used techniques, provides information about the wide selection of blotting apparatus and detection reagents available from Bio-Rad, and offers troubleshooting tips and technical advice.

Protein Blotting Guide

7

8

Protein Blotting Guide

Chapter 1 Transfer

Transfer

The initial step in any blotting experiment is the transfer of proteins from a solution or gel and immobilization of those proteins on a solid membrane support. Immobilization of proteins on a membrane makes the proteins accessible to probes for specific proteins and enables quantitative detection.
This chapter reviews the options that are available for blotting instruments and power supplies. Chapter 2 describes the various membranes, transfer buffers, and power conditions that may be used for transfer. Chapter 3 provides an overview of the steps and workflow involved in performing protein transfer. Subsequent processing of the protein blots for detection and identification is discussed in Chapter 4.

Proteins Electrophoretically Separated in a Gel

Protein Sample in Free Solution

Sample Matrix

Electrophoretic Transfer

Tank Transfer

Semi-Dry Transfer

Microfiltration (Dot-Blotting)

Transfer Method

Mini Trans-Blot®
Cell

CriterionTM Blotter

Trans-Blot® Trans-Blot®

Cell

Plus Cell

Trans-Blot SD Cell

Bio-Dot® Apparatus

Bio-Dot SF Apparatus

Products

Transfer Methods

Fig. 1.1. Protein transfer systems.

Proteins can be transferred to membranes by a number of methods. The most common are electrophoretic transfer and microfiltration (dot-blotting). Although diffusion or capillary blotting methods may also be used to transfer proteins from gels, generally electrophoretic transfer is used to transfer proteins following electrophoretic separation by SDS-polyacrylamide gel electrophoresis (SDS-PAGE) or by native PAGE -- whereas microfiltration is used to transfer proteins that are in solution (Figure 1.1). Electrophoretic transfer of proteins is fast, efficient, and preserves the high-resolution separation of proteins by PAGE. Microfiltration is particularly useful to determine working conditions for a new blotting assay or in any other situation where the resolving power of gel electrophoresis is not needed.

Protein Blotting Guide

9

Chapter 1

Transfer

­

Cathode

Filter paper

Gel

Membrane

Filter paper

+

Anode

Fig. 1.2. Gel and membrane setup for electrophoretic transfer.

Electrophoretic Transfer
Electrophoretic methods are used to elute proteins from gels and transfer them to membranes. Electrophoretic transfer is the most widely used blotting method because of its speed and precision in replicating the pattern of separated proteins from a gel to a membrane.
The Principle of Electrophoretic Transfer In an electrophoretic transfer, the membrane and protein-containing gel are placed together with filter paper between two electrodes (Figure 1.2). Proteins migrate to the membrane following a current (I) that is generated by applying a voltage (V) across the electrodes, following Ohm's law:
V = I x R
where R is the resistance generated by the materials placed between the electrodes (that is, the transfer buffer, gel, membrane, and filter papers).
The electric field strength (V/cm) that is generated between the electrodes is the driving force for electrophoretic transfer. Though a number of other factors, including the size, shape, and charge of the protein and the pH, viscosity, and ionic strength of the transfer buffer and gel %T may influence the elution of particular proteins from gels, both the applied voltage and the distance

between the electrodes play a major role in governing the rate of elution of the proteins from the gel. There are practical limits on field strength, however, due to the production of heat during transfer.
The heat generated during a transfer (Joule heating) is proportional to the power consumed by the electrical elements (P), which is equal to the product of the current (I) and voltage (V).
P = I x V = I2 x R
Joule heating increases temperature and decreases resistance of the transfer buffer. Such changes in resistance may lead to inconsistent field strength and transfer, or may cause the transfer buffer to lose its buffering capacity. In addition, excessive heat may cause the gel to deteriorate and stick to the membrane. The major limitation of any electrophoretic transfer method is the ability of the chamber to dissipate heat.
Types of Electrophoretic Transfer There are two main types of electrophoretic blotting apparatus and transfer procedures: tank, or wet transfer, where gels and membranes are submerged under transfer buffer in tanks, and semi-dry transfer, where gels and membranes are sandwiched between buffer-wetted filter papers that are in direct contact with flat-plate electrodes. The two types of transfer systems are compared in Table 1.1.

Table 1.1. Comparison of electrophoretic protein transfer systems.

Flexibility
Quantitative vs. qualitative results Molecular weight range

Tank Blotting
Flexible voltage settings, blotting times, and cooling requirements; flexible electrode positions (Trans-Blot and Trans-Blot Plus cells)
Quantitative transfer of low molecular weight proteins possible under conditions that allow efficient binding to the membrane
Broad molecular weight range

Transfer time Temperature control Buffer capacity

Extended transfer (up to 24 hr) possible without buffer depletion; rapid transfers (15­60 min) obtained under high-intensity conditions
Specific temperature regulation with cooling coil and refrigerated water recirculator; permits transfers at low temperatures (4­10°C), for example, native enzyme transfers
Up to 10­12 L (Trans-Blot Plus cell) or as little as 450 ml (Mini Trans-Blot cell); length of blotting time not restricted by limited buffer capacity

Semi-Dry Blotting Dedicated to rapid transfer with minimal transfer buffer, without cooling
Some low molecular weight molecules will be transferred through the membrane without binding quantitatively Variable transfer efficiencies for proteins >120 kD (may be improved with discontinuous buffer system); low molecular weight proteins may be transferred through membrane Rapid transfers; extended transfers not possible due to buffer depletion
Temperature regulation by external cooling is not possible
Minimal, ~250 ml per experiment; reduced cost of reagents and experiment time

10 Protein Blotting Guide

Transfer

Chapter 1

Tank Blotting In tank transfer systems, the gel and membrane sandwich is entirely submerged under transfer buffer within a buffer tank. A nonconducting cassette holds the membrane in close contact with the gel and the cassette assembly is placed in the tank between the electrodes, transverse to the electrical field, and submerged under conducting transfer buffer (Burnette 1981, Gershoni et al. 1985, Towbin et al. 1979). Although large volumes of buffer in the tank dissipate the heat generated during transfer and provide the conducting capacity for extended transfer conditions, additional cooling mechanisms are offered by the various tank blotter systems.
Tank transfer systems contain the following elements:
· Buffer tank and lid -- The buffer tank and lid combine to fully enclose the inner chamber during electrophoresis. On the inside, the tank has slots for placement of the electrode cards, gel holder cassettes, and the cooling element. Ports on the lid allow connection points for the electrodes
· Gel holder cassette -- The gel and membrane sandwich is held together between two fiber pads and filter paper sheets and placed into the tank within a gel holder cassette. Cassettes are made of nonconducting material and are designed to permit unimpeded flow of current and buffer through the gel and membrane sandwich
· Electrodes -- Tank transfer systems use either plate or wire electrode cards. Plate electrodes offer greater field strength than wire electrodes, but wire electrodes may be more economical and generate less heat
· Cooling mechanism -- Cooling systems consist of an in ice block, a sealed ice unit, or a cooling coil that is coupled to an external cooling mechanism. These cooling systems prevent temperature fluctuations and overheating during highintensity, extended, or native protein transfers

Tank transfer systems are recommended for most routine protein work, for efficient and quantitative protein transfers, and for transfers of proteins of all sizes.
Semi-Dry Blotting In a semi-dry transfer, the gel and membrane are sandwiched between two stacks of filter paper and are in direct contact with plate electrodes (Bjerrum and Schafer-Nielsen 1986, Kyhse-Andersen 1984, Tovey and Baldo 1987). The term "semi-dry" refers to the limited amount of buffer, which is confined to the two stacks of filter paper.
In semi-dry systems, the distance between the electrodes is limited only by the thickness of the gel/membrane sandwich. As a result, high electric field strengths and high-intensity blotting conditions are achieved. Under semidry conditions, some small proteins may be driven through the membrane in response to the high field strengths. Moreover, because low buffer capacity limits run times, some large proteins may be poorly transferred. Use of a discontinuous buffer system (see Chapter 2) may enhance semi-dry transfer of high molecular weight proteins (>80 kD). As semi-dry transfers require considerably less buffer and are easier to set up than the tank method, laboratories performing large numbers of blots often favor them.
Microfiltration (Dot-Blotting)
Simple, bulk transfer of proteins that are in solution may be achieved by manual application (dotting) to a membrane from a pipet or syringe, or by vacuum-assisted microfiltration. Manual dot-blotting with a pipet or syringe is generally used for small sample volumes. Microfiltration devices, on the other hand, enable application of larger volumes, multiple assays with different probes, and quick, reproducible screening of a large number of samples.
Microfiltration facilitates the determination of working conditions for a new blotting assay and is a convenient method in any other situation where the resolving power of gel electrophoresis is not needed.

Protein Blotting Guide 11

Chapter 1

Transfer

Blotting Systems and Power Supplies

5
4
Fig. 1.3. The Trans-Blot cell. 1, buffer tank and lid; 2, gel holder cassette and fiber pads; 3, wire electrodes; 4, plate electrodes; 5, super cooling coil.

Transfer Apparatus
The transfer of proteins to a membrane support is accomplished by electrophoresis (tank or semi-dry blotting) for gels and by microfiltration (dot-blotting) for proteins in solution.
Tank Blotting Apparatus Tank transfer systems offer flexibility in choosing voltage settings, blotting times, and cooling options. Tank transfer systems provide efficient and quantitative protein transfers over a broad molecular weight range. The tank transfer systems offered by Bio-Rad are described below, and their specifications are summarized in Table 1.2.
Trans-Blot Cell The Trans-Blot cell (Figure 1.3) offers a choice of plate or wire electrodes and variable placement of the electrodes for
1
2
3
1

both standard and high-intensity blotting options. The Trans-Blot cell accommodates three gel holder cassettes, each with a 16 x 20 cm blotting area. Standard field transfers are performed with the electrodes placed 8 cm apart; with this arrangement, all three of the gel holder cassettes may be used simultaneously. High-intensity transfers are performed with the electrodes placed 4 cm apart, with a single gel holder cassette between them. Temperature regulation can be achieved by using the super cooling coil (included) and a refrigerated water recirculator (purchased separately).
Trans-Blot Plus Cell The Trans-Blot Plus cell (Figure 1.4) is designed to provide efficient transfers of protein from large format (28 x 26.5 cm) gels. The Trans-Blot Plus has the capacity to transfer three large format gels or multiple smaller format gels simultaneously in as little as 15­30 min. Each gel holder cassette is constructed of a durable material that, along with an effective clamping mechanism, ensures tight, uniform contact between the gel and membrane across the entire blotting area. A detachable hinge mechanism in the cassette virtually eliminates shifting of gel sandwiches during assembly. Plate electrodes provide a strong and uniform electrical field and are movable -- one, two, or three gel cassettes can be placed in the

4 2
Fig. 1.4. The Trans-Blot Plus cell. 1, buffer tank and lid; 2, gel holder cassette and fiber pads; 3, plate electrodes; 4, super cooling coil.
3
12 Protein Blotting Guide

Transfer

Chapter 1

tank with the minimum electrode distance between them, increasing the field strength and efficiency of transfer. A cooling coil coupled to a refrigerated water recirculator provides effective temperature regulation, ensuring effective and reproducible transfers even during high-intensity, high-power applications.
Mini Trans-Blot Cell and Criterion Blotter The Mini Trans-Blot cell and the Criterion blotter accommodate smaller gels for rapid, high-quality blotting. The Mini Trans-Blot cell (Figure 1.5) can transfer up to two mini gels (10 x 7.5 cm) in an hour and is available either as a complete apparatus, or as a module that uses the buffer tank and lid of the Mini-PROTEAN® 3 cell for operation. The Criterion blotter (Figure 1.6) can transfer up to two Criterion gels (15 x 9.4 cm) or four mini gels in 30­60 min. A selfcontained Bio-Ice cooling unit absorbs the heat generated during transfer in the Mini Trans-Blot cell, and the Criterion blotter uses a sealed ice block or optional cooling coil to regulate temperature during transfer.

1
Fig. 1.5. The Mini Trans-Blot

cell. 1, buffer tank and lid; 2, gel

4

holder cassette; 3, electrode

assembly; 4, Bio-IceTM cooling unit.

3 2
1 6

Fig. 1.6. The Criterion blotter. 1, buffer tank and lid; 2, assembly tray with roller, fiber pads, blotting filter paper, and gel holder cassettes; 3, wire electrodes; 4, plate electrodes; 5, sealed ice block; 6, optional cooling coil.

5

2

4

3

Table 1.2. Specifications for tank blotting cells.

Blotting area Number of cassettes Buffer requirements Electrode distance Electrode materials
Transfer time
Cooling

Trans-Blot
Standard: 16 x 20 cm
1 for high-intensity transfer, 2 with cooling, 3 without cooling
2.5 L
Flexible; 2 positions: 4 and 8 cm
Platinum-coated titanium anode and stainless-steel cathode plates or platinum wire
Standard: 2­5 hr (wire electrodes), 1­2 hr (plate electrodes) High-intensity: 1­2 hr (wire electrodes), 0.5­1 hr plate electrodes
Super cooling coil

Trans-Blot Plus Extra large: 28 x 26.5 cm 3

Mini Trans-Blot Mini: 10 x 7.5 cm 2

10­12 L
Flexible; 3 positions: 4, 7, and 10 cm
Platinum-coated titanium anode and stainless-steel cathode plates
Standard: 16 hr (overnight)

450 ml 4 cm Platinum wire
1 hr

High-intensity: 0.25­1 hr

Super cooling coil

Bio-Ice cooling unit

Dimensions (W x L x H)

18 x 9.5 x 24 cm

30 x 17.3 x 39.4 cm

12 x 16 x 18 cm

Criterion Blotter Midi: 15 x 9.4 cm 2
1.3 L 4.3 cm
Platinum-coated titanium anode and stainless-steel cathode plates or platinum wire 0.5­1 hr (wire electrodes)
0.5 hr (plate electrodes)
Sealed ice block or optional Criterion blotter cooling coil 21.8 x 11.8 x 15 cm

Protein Blotting Guide 13

Chapter 1

Transfer

1 2
3 Fig. 1.7. The Trans-Blot SD cell. 1, lid; 2, cathode plate; 3, anode plate.
1
2
Fig.1.8. Microfiltration apparatus. 1, Bio-Dot microfiltration unit; 2, Bio-Dot SF microfiltration unit.

Semi-Dry Blotting Apparatus Semi-dry transfers allow fast, efficient, economical blotting without a buffer tank or gel cassettes.
Trans-Blot SD Semi-Dry Cell The Trans-Blot SD semi-dry cell (Figure 1.7) performs high-intensity electrophoretic transfers quickly and efficiently without requiring external cooling. Most mini gel transfers are accomplished in less than 30 minutes. Plate electrodes and a unique single-step locking system designed for the Trans-Blot SD cell make assembly easy and ensure uniform contact across the entire electrode surface. See Table 1.3 for detailed specifications.

Table 1.3. Trans-Blot SD semi-dry cell specifications.

Maximum gel size (W x L) Gel capacity
Buffer requirement Electrode dimensions Electrode distance Electrode materials Cooling Dimensions (W x L x H)

24 x 16 cm Two PROTEAN® II gel sandwiches, stacked and separated by dialysis membrane; four Mini-PROTEAN 3 gels side by side; three Criterion gels side by side ~200 ml 25 x 18 cm Determined by thickness of the gel sandwich and filter paper stack Platinum-coated titanium anode and stainless-steel cathode N/A 37 x 24 x 11 cm

Microfiltration Apparatus Microfiltration units allow use of easy, reproducible methods for binding proteins in solution onto membranes.
Bio-Dot® and Bio-Dot SF Apparatus The Bio-Dot and the Bio-Dot SF (slot-format) microfiltration units (Figure 1.8) provide reproducible binding of proteins in solution onto membranes. Samples are loaded into the wells of the templates and proteins are trapped on the membrane by filtration using either vacuum or gravity flow. Once samples are loaded, incubations, wash steps, and detection may all be performed without removing the membrane from the unit.
The 96-well Bio-Dot apparatus performs traditional dot-blot comparisons while the 48-well Bio-Dot SF apparatus focuses the applied samples into thin lines instead of circles (Figure 1.9). This slot format makes it easier to use a densitometer for quantitation. The Bio-Dot and Bio-Dot SF sample templates are interchangeable; each uses the same microfiltration manifold. Each apparatus is available as an independent unit, containing both the microfiltration manifold and the sample template, and also as a modular template without the manifold base.

1 2 3 4 5 6 7 8 9 10 A
B
C
D 1 2 3 4 5 6

Fig. 1.9. Multiple sample comparisons are simplified with the Bio-Dot and Bio-Dot SF microfiltration units. A and B, antigen (human transferrin) applied to nitrocellulose in each row of the Bio-Dot apparatus. 1, 100 ng; 2, 50 ng; 3, 25 ng; 4, 10 ng; 5, 5 ng; 6, 2.5 ng; 7, 1 ng; 8, 0.5 ng; 9, 0.25 ng; 10, 1% BSA in TBS. C and D, antigen applied to each row of the Bio-Dot SF apparatus. 1, 100 ng; 2, 50 ng; 3, 10 ng; 4, 5 ng; 5, 1 ng; 6, 0.1 ng. The membranes were incubated with rabbit anti-human transferrin. In A and C, Bio-Rad's goat anti-rabbit gold conjugate and gold enhancement kit were used to visualize the antigen. In B and D, Bio-Rad's goat anti-rabbit AP conjugate and the color development reagents BCIP and NBT were used to visualize the antigen.

14 Protein Blotting Guide

Transfer

Chapter 1

The Bio-Dot and Bio-Dot SF units may be easily sterilized by autoclaving or by washing in alcohol or sodium hydroxide (NaOH). The units feature a unique, patented sealing gasket that eliminates lateral leakage and possible cross-contamination between wells. Both sample templates are spaced similarly to microplates so that samples can be applied with a standard or multichannel pipet. Specifications for the Bio-Dot units are listed in Table 1.4.

Table 1.4. Bio-Dot apparatus specifications.

Sample format Well size Sample volume Membrane size (W x L) Autoclavability

Bio-Dot 96-well, 8 x 12 format 3 mm diameter 50­600 µl 9 x 12 cm Yes

Bio-Dot SF 48-slot, 6 x 8 format 7 x 0.75 mm 50­500 µl 9 x 12 cm Yes

Power Supplies for Electrophoretic Transfers
Electrophoretic transfer cells require high currents that not all power supplies are equipped to deliver. Table 1.5 compares the two Bio-Rad power supplies (Figure 1.10) that accommodate the needs of electrophoretic transfer systems.
PowerPacTM HC Power Supply The PowerPac HC (high current) power supply, with a 250 V, 3.0 A, 300 W output, is capable of driving all transfer cells to their maximum performance. The PowerPac HC has replaced the 200 V, 2.0 A PowerPacTM 200 power supply and offers high power output and the flexibility of choosing transfer under constant voltage, constant current, or constant power settings. The PowerPac HC also offers highly regulated voltage settings, fine adjustment of current limits, and a convenient pause function. Safety features include overload/short circuit detection, automatic crossover, arc and ground leak detection, programmable multistep methods, and a programmable timer.
PowerPacTM Universal Power Supply The PowerPac Universal power supply is for researchers demanding a power supply capable of performing the broadest range of applications possible. With 500 V, 2.5 A, 500 W output, the PowerPac Universal is designed to drive all of the most common electrophoretic applications, with the exception of high-voltage applications such as isoelectric focusing and DNA sequencing. Like the PowerPac HC, the PowerPac Universal provides the choice of transfer under constant voltage, constant current, or constant power settings with all of the other features listed above. In addition, the PowerPac Universal stores up to nine methods, each with up to nine steps, and is equipped to enable wireless transfer of run data and protocols for instrument validation for regulatory purposes (for example, installation qualification and operational qualification, or IQ/OQ).

Table 1.5. PowerPac HC and PowerPac Universal power supply specifications.

Voltage Current Power

PowerPac HC 5­250 V 0.01­3.0 A 1­300 W

PowerPac Universal 5­500 V 0.01­2.5 A 1­500 W

Fig. 1.10. Power supplies. PowerPac HC (top) and PowerPac Universal (bottom) power supplies.

Protein Blotting Guide 15

16 Protein Blotting Guide

Chapter 2
Membranes, Buffers, and Power Conditions

Membranes, Buffers, and Power Conditions

Selecting the appropriate membrane, transfer buffer, and power conditions is critical to successful protein transfer. The size and charge of the proteins, the transfer method, and the binding properties of the membrane must all be considered. This chapter provides technical information and advice for selecting among the various conditions that are available for protein transfer. Subsequent processing of the transferred proteins for detection and identification is discussed in Chapter 4.

Membrane Selection

Though nitrocellulose was once the only choice for protein blotting, advances in membrane chemistries have made a variety of membrane types available, each offering key attributes to suit particular experimental conditions. The physical properties and performance characteristics of a membrane should be evaluated when selecting the appropriate transfer conditions (Table 2.1).
Membranes are commonly available in two pore sizes: the 0.45 µm pore size membranes are recommended for most analytical blotting experiments, while the 0.2 µm pore size membranes are most suitable for transfer of low molecular weight (<15,000) proteins that might move through larger membrane pores.

Nitrocellulose and Supported Nitrocellulose
Nitrocellulose was one of the first membranes used for western blotting and is still a popular membrane for this procedure. Protein binding to nitrocellulose is instantaneous, nearly irreversible, and quantitative up to 80 to 100 µg/cm2. Nitrocellulose is easily wetted in water or transfer buffer and is compatible with a wide range of protein detection systems.
Supported nitrocellulose is an inert support structure with nitrocellulose applied to it. The support structure gives the membrane increased strength and resilience. Supported nitrocellulose can withstand reprobing and autoclaving (121°C) and retains the ease of wetting and protein binding features of nitrocellulose.

Table 2.1. Guide to protein blotting membranes.

Membrane Nitrocellulose
Supported nitrocellulose

Pore Size
0.45 µm 0.2 µm
0.45 µm 0.2 µm

Binding Capacity (µg/cm2) 80­100
80­100

Sequi-Blot PVDF

0.2 µm

170­200

Immun-Blot PVDF

0.2 µm

150­160

Notes General-purpose protein blotting membrane
Pure nitrocellulose cast on an inert synthetic support; increased strength for easier handling and for reprobing High mechanical strength and chemical stability; used for protein sequencing High mechanical strength and chemical stability; recommended for western blotting

Protein Blotting Guide 17

Chapter 2

Membranes, Buffers, and Power Conditions

Polyvinylidene Difluoride (PVDF) Membrane
PVDF membrane is an ideal support for N-terminal sequencing, amino acid analysis, and immunoassay of blotted proteins. PVDF retains proteins during exposure to acidic or basic conditions and in the presence of organic solvents. Greater protein retention during sequencing manipulations enhances the likelihood of obtaining information from rare, low-abundance proteins by increased initial coupling and higher repetitive yields. In addition, PVDF membrane exhibits better binding efficiency of electroblotted material in the presence of SDS in the transfer buffer. PVDF membrane must be wetted in 100% methanol prior to use but may be used with a transfer buffer that contains no methanol.
Bio-Rad offers PVDF membrane specifically designed for protein sequencing and for immunodetection. Both are available in precut sheets, rolls, and sandwich formats.

Sequi-BlotTM PVDF for Protein Sequencing Originally named Bio-Rad PVDF membrane, Sequi-Blot PVDF membrane withstands the conditions of N-terminal sequencing while providing the binding capacity to sequence even low-abundance samples. See Figure 2.1.
Immun-Blot® PVDF for Western Blotting Immun-Blot PVDF membrane is ideal for chemiluminescent and colorimetric western blots because it retains target protein but resists nonspecific protein binding that can obscure high-sensitivity detection. Immun-Blot PVDF has a strong binding capacity of 150­160 µg/cm2 (roughly twice that of nitrocellulose), will not crack or tear in common handling, and holds up under repeated stripping and reprobing.

Fig. 2.1. Superior retention of proteins by Bio-Rad's Sequi-Blot PVDF membrane. Protein samples were blotted to PVDF membrane support (diagrammed on left) using Towbin buffer containing 0.1% SDS. Membrane A, the membrane sheet closest to the gel; membrane B, a second sheet of membrane layered behind the first.

Gel holder
Fiber pad Filter paper
Gel PVDF membrane A PVDF membrane B
Filter paper
Fiber pad Gel holder

Cathode Anode

Sequi-Blot PVDF Sequi-Blot PVDF

Membrane A

Membrane B

Blotting Filter Paper
Blotting filter paper, made of 100% cotton fiber, provides a uniform flow of buffer through the gel. This paper contains no additives that might interfere with the transfer process. Precut filter paper is

available in a wide range of convenient sizes to eliminate waste and save time (Table 2.2). Extra thick absorbent filter paper is recommended for semi-dry transfers because of its additional fluid capacity.

18 Protein Blotting Guide

Membranes, Buffers, and Power Conditions

Chapter 2

Table 2.2. Guide to precut membranes and filter paper.

Electrophoretic Blotting Apparatus Trans-Blot® cell Trans-Blot® Plus cell Trans-Blot SD cell
Mini Trans-Blot® cell CriterionTM blotter Bio-Dot® apparatus Bio-Dot SF apparatus

Precut Membranes
13.5 x 16.5 cm 26.5 x 28 cm 7 x 8.4 cm 11.5 x 16 cm 15 x 15 cm 15 x 9.2 cm 20 x 20 cm 7 x 8.4 cm
8.5 x 13.5 cm 9 x 12 cm 9 x 12 cm

Precut Blot Filter Papers 15 x 20 cm 26.5 x 28 cm 15 x 15 cm (extra thick)
7.5 x 10 cm 9.5 x 15.2 cm N/A 11.3 x 7.7 cm

Membrane/Filter Paper Sandwiches

Precut and preassembled sandwiches save time and effort during western blot preparation. In Bio-Rad's membrane sandwiches, a precut membrane
Transfer Buffer Selection

(nitrocellulose or PVDF) and two sheets of 100% cotton fiber thick filter paper are preassembled into a blotting membrane/ filter paper sandwich.

Different gel types and blotting applications call for different transfer buffers (Tables 2.3 and 2.4), but in general, transfer buffer must enable both effective elution of proteins from the gel matrix and binding of the protein to the membrane. The choice of buffer will depend on the type of gel and membrane being used as well as the physical characteristics of the protein of interest.

Transfer buffers contain a conductive, strong buffering agent (for example, Tris, CAPS, or carbonate) in order to maintain the conductivity and pH of the system during transfer. In addition, alcohol (for example, methanol or ethanol) may be included in the transfer buffer to promote binding of proteins to membranes, and SDS may be added to promote elution of proteins from gels.

Table 2.3. General guidelines on transfer buffer and membrane selection by gel type.

Gel Type SDS-PAGE
Tris-Tricine SDS-PAGE

Transfer Buffer
Towbin, with or without SDS, CAPS, carbonate, Bjerrum Schafer-Nielsen Towbin, CAPS

Membrane
Nitrocellulose or supported nitrocellulose, 0.45 or 0.2 µm, or PVDF
Nitrocellulose or supported nitrocellulose, 0.2 µm, or PVDF

Two-dimensional gel Native, nondenaturing Acid urea

Towbin, with or without SDS, CAPS, carbonate, Bjerrum Schafer-Nielsen
Depends on pH of gel buffer and pI of protein of interest
0.7% acetic acid

Nitrocellulose or supported nitrocellulose, 0.45 or 0.2 µm, or PVDF
Nitrocellulose, 0.45 or 0.2 µm, or PVDF
Nitrocellulose, 0.45 or 0.2 µm

Isoelectric focusing gel 0.7% acetic acid

Nitrocellulose or supported nitrocellulose, 0.45 or 0.2 µm, or PVDF

Notes Tank blotting or semi-dry blotting
Tank blotting recommended; needs high-capacity, small-pore-size membrane; pH of buffer may be critical Tank blotting or semi-dry blotting
Specific temperature regulation may be needed to maintain activity Use acid-gel transfer protocol (membrane toward cathode) Use acid-gel transfer protocol (membrane toward cathode)

Protein Blotting Guide 19

Chapter 2

Membranes, Buffers, and Power Conditions

Table 2.4. General guidelines on transfer buffer and membrane selection by application.

Special Applications
Protein sequencing High molecular weight proteins

Transfer Buffer Towbin,* CAPS Towbin with SDS

Small proteins and peptides Basic proteins (pI >9) run in denaturing gels Basic proteins (pI >9) run in native or nondenaturing gels Glycoproteins
Proteoglycans

Towbin, CAPS
CAPS, carbonate, Bjerrum Schafer-Nielsen 0.7% acetic acid
Towbin, with or without SDS, CAPS, carbonate, Bjerrum Schafer-Nielsen Towbin, Bjerrum Schafer-Nielsen

Membrane Nitrocellulose, 0.45 or 0.2 µm, or PVDF Nitrocellulose, 0.45 or 0.2 µm, or PVDF
Nitrocellulose, 0.2 µm, or PVDF Nitrocellulose, 0.45 or 0.2 µm, or PVDF Nitrocellulose, 0.45 or 0.2 µm, or PVDF
Nitrocellulose, 0.45 or 0.2 µm, or PVDF Nitrocellulose, 0.45 or 0.2 µm, or PVDF

Notes Tank blotting recommended Tank blotting recommended; needs high-capacity, small-pore-size membrane; pH of buffer may be critical Tank blotting recommended; pH of buffer may be critical Tank blotting or semi-dry blotting
Tank blotting recommended
Tank blotting or semi-dry blotting
Tank blotting or semi-dry blotting

* Towbin buffer may be used for protein sequencing but extra care must be exercised to rinse Tris and glycine from the membrane after transfer.

General Recommendations
Regardless of which transfer buffer is selected, transfer buffer should never be used more than once, since the buffer will likely lose its capacity to maintain a stable pH during transfer. Similarly, diluting transfer buffers is not advised, since this will decrease their buffering capacity. Lastly, adjusting the pH of transfer buffers when not indicated will result in increased buffer conductivity, manifested by higher initial current output and decreased resistance.
Recipes for all of the buffers described in this section are provided in the Appendix.
A Note About SDS and Alcohol SDS and alcohol play opposing roles in a transfer.
SDS in the gel and in the SDS-protein complexes promotes elution of the protein from the gel but inhibits binding of the protein to membranes. In cases where certain proteins are difficult to elute from the gel, SDS may be added to the transfer buffer to improve transfer. SDS in the transfer buffer decreases the binding efficiency of protein to nitrocellulose membrane; PVDF membrane can be substituted for nitrocellulose when SDS is used in the transfer buffer. Addition of SDS will increase the relative current, power, and heating during transfer, and may also affect the antigenicity of some proteins.

Alcohol (methanol or ethanol), on the other hand, removes the SDS from SDS-protein complexes and improves the binding of protein to nitrocellulose membrane, but has some negative effects on the gel itself. Alcohol may cause a reduction in pore size, precipitation of some proteins, and some basic proteins to become positively charged or neutral. All of these factors will affect blotting efficiency.
Note: Only high-quality, analytical grade methanol should be used in transfer buffer; impure methanol can cause increased transfer buffer conductivity and poor transfer.
Towbin and Bjerrum and Schafer-Nielsen Buffers (Tris/Glycine Buffers)
The most common transfers are from SDS-PAGE gels using the buffer systems originally described by Towbin (1979). Standard Towbin buffer contains 25 mM Tris, pH 8.3, 192 mM glycine, 20% (v/v) methanol and, occasionally, 0.025­0.1% (w/v) SDS. A buffer similar in composition to the standard Towbin buffer is the Bjerrum and Schafer-Nielsen buffer (48 mM Tris, pH 9.2, 39 mM glycine, 20% methanol), which was developed for use in semi-dry applications.

20 Protein Blotting Guide

Membranes, Buffers, and Power Conditions

Chapter 2

CAPS Buffer
CAPS-based transfer buffers (10 mM CAPS, pH 11, 10% methanol) may be preferable for transfers of high molecular weight proteins (for example, >50 kD) and in cases where the glycine component of Towbin buffer may interfere with downstream protein sequencing applications.
Discontinuous Tris-CAPS Buffer System (Semi-Dry Transfers)
A unique feature of semi-dry blotting is the ability to use two different buffers during transfer, known as a discontinuous buffer system. This is possible because in a semidry transfer, the buffer reservoirs are the filter paper on either side of the gel, which are independent. In a discontinuous system, methanol is included in the buffer on the membrane (anode) side of the blot assembly and SDS is used on the gel (cathode) side, taking advantage of the positive effects of each buffer component.
A discontinuous buffer system using a Tris-CAPS buffer can greatly increase the efficiency of protein transfer by semi-dry blotting. This system uses 60 mM Tris, 40 mM CAPS, pH 9.6, plus 15% methanol in the filter paper on the anode side and 0.1% SDS on the cathode side. Concentrated, premixed anode and cathode buffers are available for purchase. For more information about the use of a discontinuous buffer system in semi-dry transfer, request bulletin 2134.

Dunn Carbonate Buffer
In some cases, using a carbonate buffer (10 mM NaHCO3, 3 mM Na2CO3, pH 9.9, 20% methanol) may produce higher efficiency transfers and improve the ability of antibodies to recognize and bind to proteins. Carbonate buffer has also been recommended for the transfer of basic proteins (Garfin and Bers 1989).
Alternative Buffer Conditions
The mobility of proteins during electrophoretic transfer from native gels will depend on the size and pI of the protein of interest relative to the pH of the buffer used.
· If the pI of the protein is greater than the pH of the transfer buffer, the protein will carry a positive charge and will migrate toward the negative electrode
· If the pI of the protein is close to the pH of the transfer buffer, the migration of the protein out of the gel will be decreased. A more basic or acidic buffer should be used to increase protein mobility
Proteins in native gels as well as acidic and neutral proteins require buffers that do not contain methanol. Gels for isoelectric focusing, native PAGE, and those containing basic proteins or acid-urea may be transferred in 0.7% acetic acid. When using acetic acid for transfer, the proteins will be positively charged, so the membrane should be placed on the cathode side of the gel.

Power Conditions for Electrophoretic Transfers

The optimal condition for electrophoretic transfer is to run at the highest electric field strength (V/cm) possible within the heat dissipation capabilities of the system; that is, for most proteins, the most rapid transfer occurs under conditions where the applied voltage (V) is maximized and the distance

between the electrodes is minimized. Though rapid blotting experiments may seem most convenient, a number of factors must be considered when choosing the appropriate power conditions for a given electrophoretic transfer.

Protein Blotting Guide 21

Chapter 2

Membranes, Buffers, and Power Conditions

Useful Equations
Two basic electrical equations are important in electrophoresis. The first is Ohm's law, which relates the applied voltage (V), with the current (I) and resistance (R) of the system:
V = I x R
The applied voltage and current are determined by the user and the power supply settings; the resistance is inherent in the system.
The second equation, the power equation, describes the power (P) used by a system, which is proportional to the voltage (V), current (I), and resistance of the system (R).
P = I x V = I2 x R = V2/R
Understanding the relationships between power, voltage, current, resistance, and heat is central to understanding the factors that influence the efficiency and efficacy of transfer.
Joule Heating
The power that is dissipated is also equivalent to the amount of heat, known as Joule heating, generated by the system. According to the power equation, the amount of Joule heating that occurs depends on the conductivity of the transfer buffer used, the magnitude of the applied field, and the total resistance within the transfer system.
During the course of an electrophoretic transfer, the transfer buffer is warmed as a result of Joule heating. Consequently, its resistance drops. Such heating and changes in resistance may lead to inconsistent field strength and transfer, may cause the transfer buffer to lose its buffering capacity, or may cause the gel to melt and stick to the membrane.
Under normal running conditions, the transfer buffer absorbs most of the heat that is generated. During extended transfer periods or high-power conditions, active buffer cooling is required to prevent uncontrolled temperature increases.

Other Factors Affecting Transfer
The following variables will also change resistance of the transfer system and will, therefore, also affect transfer efficiency and current and voltage readings:
· Alterations to buffer makeup; that is, addition of SDS or changes in ion concentration due to addition of acid or base to adjust the pH of a buffer
· Gel pH, ionic strength, and percentage of acrylamide, especially if the gel has not been properly equilibrated
· Number of gels (current increases slightly as the number of gels increases)
· Volume of buffer (current increases when volume increases)
· Transfer temperature (current increases when temperature increases)
Relationship Between Power Settings and Transfer Times
In theory, increasing the power input and duration of an electrophoretic transfer results in the transfer of more protein out of a gel. However, in practice, initial test runs should be used to evaluate transfer efficiency at various field strengths (by modulating both power input and, if applicable, interelectrode distance) and transfer times for each set of proteins of interest. The optimum transfer conditions will actually vary according to a number of factors, including the size, charge, and electrophoretic mobility of the protein, the type of transfer buffer used, and the type of transfer system being used.
High-Intensity Field Transfers As their name suggests, high-intensity field transfers use high-strength electrical fields that are generated by increased voltage and closer positioning of electrodes. Highintensity transfers generally require less than 5 hr to complete. Though high-intensity transfers often produce satisfactory transfer

22 Protein Blotting Guide

Membranes, Buffers, and Power Conditions

Chapter 2

of proteins in less time, in some cases the high electric field strength may cause small proteins to be transferred too quickly and through the membrane. In addition, high molecular weight proteins, and other proteins that are difficult to transfer, may not have sufficient time to be transferred completely. Since more heat is generated in high-intensity filed transfers than in standard field transfers, a cooling device may be needed.
Standard Field Transfers These transfers require less power input and more time to complete; they are generally run overnight. Standard transfers often produce more complete, quantitative transfer of proteins across a broad molecular weight range; the slower transfer conditions allow large proteins sufficient time to move through the gel matrix while the lower intensity allows smaller proteins to remain attached to the membrane after transfer.
Tank transfer systems offer the capacity for both high-intensity and standard-field transfers. Increased buffering capacity and additional cooling mechanisms enable longer transfer times than are feasible with semi-dry transfers. Some tank transfer systems offer flexible electrode positions that, when combined with variable voltages, provide a choice of high-intensity, rapid transfer or longer, more quantitative transfer over a broad range of molecular weights.
Semi-dry transfers, on the other hand, are necessarily rapid and of high intensity. In a semi-dry transfer system, the distance between electrodes is determined only by the thickness of the gel-membrane sandwich and buffering and cooling capacity is limited to the buffer in the filter paper. As a result, the field strength is maximized in semi-dry systems, and the limited buffering and cooling capacity restricts the transfer time. Though power conditions may be varied with the power supply, semi-dry transfers often operate best within a narrow range of settings.

Selecting Power Supply Settings
Power supplies that are used for electrophoresis hold one parameter constant (either voltage, current, or power). The PowerPacTM HC and PowerPacTM Universal power supplies also have an automatic crossover capability that allows the power supply to switch over to a variable parameter if a set output limit is reached. This helps prevent damage to the transfer cell.
During transfer, if the resistance in the system decreases as a result of Joule heating, the consequences are different and depend on which parameter is held constant.
Transfers Under Constant Voltage If the voltage is held constant throughout a transfer, the current in most transfer systems will increase as the resistance drops due to heating (the exception is most semi-dry systems, where current will actually drop as a result of buffer depletion). Therefore, the overall power will increase during transfer and more heating will occur. Despite the increased risk of heating, a constant voltage ensures that field strength will remain constant, providing the most efficient transfer possible. Use of the cooling elements available with the various tank blotting systems should prevent problems with heating.
Transfers Under Constant Current If the current is held constant during a run, a decrease in resistance will result in a decrease in voltage and power. Though heating will be minimized, proteins will be transferred more slowly due to decreased field strength.
Transfers Under Constant Power If the power is held constant during a transfer, changes in resistance will result in increases in current, but to a lesser degree than when voltage is held constant. Constant power is an alternative to constant current for regulating heat production during transfer.

Protein Blotting Guide 23

Chapter 2

Membranes, Buffers, and Power Conditions

General Guidelines for Transfer Buffers and Transfer Conditions

Different transfer apparatus, when used with different buffers, will require different power settings. Tables 2.5, 2.6, and 2.7 provide general guidelines for the voltage and current settings recommended for selected buffer systems. Transfer times will need to be increased for gradient gels and may need to be decreased for low molecular weight proteins. The values presented below are guidelines -- transfer conditions should be optimized for every transfer application.
Cooling is generally required for all high-intensity transfers (except for the Trans-Blot SD) and is recommended for long, unsupervised runs.

Table 2.5. Guide to power settings for SDS-PAGE gels (Towbin buffer).

Trans-Blot cell Plate electrodes Wire electrodes
Trans-Blot Plus cell
Mini Trans-Blot cell
Criterion blotter Plate electrodes Wire electrodes
Trans-Blot SD cell

Standard (Overnight)
10 V/100 mA, 16 hr 30 V/100 mA, 16 hr 30 V/0.5 A, 16 hr 30 V/90 mA, 16 hr
10 V/50­80 mA, 16 hr 10 V/30­40 mA, 16 hr N/A

High-Intensity
50­100 V/700­1,600 mA, 30­60 min 100­200 V/300­800 mA, 30 min­4 hr 100 V/1,500 mA, 60 min 100 V/350 mA, 60 min
100 V/750­1,000 mA, 30 min 100 V/380­500 mA, 60 min Mini gels: 10­15 V/5.5 mA/cm2, 10­30 min Large gels: 15­25 V/3 mA/cm2, 30­60 min

Table 2.6. Guide to power settings for native gels (Towbin buffer, no methanol).

Trans-Blot cell Plate electrodes Wire electrodes
Trans-Blot Plus cell
Mini Trans-Blot cell
Criterion blotter Plate electrodes Wire electrodes
Trans-Blot SD cell

Standard (Overnight)

High-Intensity

10 V/100 mA, 16 hr 30 V/100 mA, 16 hr 10­30 V/0.15­0.5 A, 16 hr 30 V/90 mA, 16 hr

50­100 V/700­1,500 mA, 30­60 min 100­200 V/300­800 mA, 30 min­4 hr 100­130 V/1.7­2.3 A, 15­60 min 100 V/350 mA, 1 hr

10 V/50 mA, 16 hr 10 V/50 mA, 12 hr
N/A

100 V/830­1,000 mA, 30 min 100 V/530­600 mA, 30 min
Mini gels: 10­15 V/5.5 mA/cm2, 10­30 min Large gels: 15­25 V/3 mA/cm2, 30­60 min

Table 2.7. Guide to power settings for isoelectric focusing gels, native gels, basic proteins, and acid-urea gels (0.7% acetic acid).

Trans-Blot cell Plate electrodes Wire electrodes
Trans-Blot Plus cell
Mini Trans-Blot cell
Criterion blotter Plate electrodes Wire electrodes
Trans-Blot SD cell

Standard (Overnight)

High-Intensity

15 V/200 mA, 16 hr 30 V/200 mA, 16 hr 10­30 V/ 0.15­0.55 A, 16 hr 30 V/10 mA, 16 hr

30-60 V/600­1,000 mA, 30­60 min 100-150 V/550­850 mA, 30 min­4 hr 100­125 V/1.9­2.4 A, 15­60 min 100 V/350 mA, 1 hr

10 V/50 mA, 16 hr 10 V/50 mA, 16 hr
N/A

100 V/980­1,200 mA, 30 min 100 V/500­800 mA, 30 min
Mini gels: 10­15 V/5.5 mA/cm2, 10­30 min Large gels: 15­25 V/3 mA/cm2, 30­60 min

24 Protein Blotting Guide

Chapter 3
Performing the Transfer
Performing the Transfer
This chapter provides an overview of the steps and protocols involved in performing protein transfer. General advice for ensuring optimal results is also given. Detailed protocols and advice for each apparatus and transfer method are available in the relevant product instruction manuals. Information about choices of membranes, transfer buffers, and power settings was discussed in Chapter 2. Methods for protein detection are discussed in Chapter 4.
Electrophoretic Transfer
Overall, the procedures and principles for semi-dry and tank transfers are the same. Gels and membranes must be prewet and equilibrated with transfer buffer and the gel/membrane sandwich must be placed into the transfer apparatus in the correct orientation to ensure transfer of proteins to the membrane.
Performing a Tank Transfer
Preparing the Transfer Buffer, Gels, and Tank Assembly
1. Prepare the transfer buffer in amounts that will suffice for gel equilibration, sandwich assembly, and electrophoresis. See the instruction manual for your particular tank transfer system for guidelines. See the Appendix at the end of this manual for buffer formulations. · Use only high-quality, analytical grade methanol. Impure methanol can cause increased transfer buffer conductivity and poor transfer · Reusing the transfer buffer is not advised, since the buffer will likely lose its ability to maintain a stable pH during transfer. Diluting transfer buffers below their recommended levels is also not advised, since this will decrease their buffering capacity · Do not adjust the pH of transfer buffers unless this is specifically indicated. Adjusting the pH of transfer buffers when not indicated will result in increased buffer conductivity, manifested by higher initial current output and decreased resistance · Increased SDS in the transfer buffer leads to increased protein transfer from the gel, but decreased binding of the protein to nitrocellulose membrane. PVDF membrane can be substituted for nitrocellulose when SDS is used in the transfer buffer · Addition of SDS will increase the relative current, power, and heating during transfer, and may also affect antigenicity of some proteins · Increased methanol in the transfer buffer leads to decreased protein transfer from the gel and increased binding of the protein to nitrocellulose membrane
Protein Blotting Guide 25

Chapter 3

Performing the Transfer

Fig. 3.1. Transfer assembly for a tank transfer system (Trans-Blot cell). The cassette (1) holds the gel (2) and membrane (3) while fiber pads and filter paper (4) on both sides provide complete contact within the gel sandwich. The gel cassette is inserted vertically in the buffer tank (5).

3

2

4

4

1

5

2. Rinse gels briefly in ddH2O and equilibrate for 15 min in transfer buffer. · All gels should be equilibrated in transfer buffer to remove contaminating electrophoresis buffer salts. If salts are not removed, they will increase the conductivity of the transfer buffer and the amount of heat generated during the transfer. Also, gels will shrink or swell to various degrees in the transfer buffer depending on the acrylamide percentage and the buffer composition. Equilibration allows the gel to adjust to its final size prior to electrophoretic transfer. Equilibration is not necessary when the same buffer is used for both electrophoresis and transfer (for example, native gel transfers)
3. Place the transfer tank onto a magnetic stirplate and assemble the transfer tank with the anode and cathode cards in the correct position and orientation.
4. Add enough transfer buffer to the tank to fill it approximately halfway, add a stirbar, and begin stirring.
· The transfer buffer should be stirred during the course of all tank transfers. This will help to maintain uniform conductivity and temperature during electrophoretic transfer. Failure to properly control transfer buffer temperature results in poor transfer and poses a potential safety hazard
5. If needed, set up the cooling system for the tank transfer system. Follow instructions in the instruction manual.
· Electrophoretic transfer entails large power loads and, consequently, heat generation. The tanks are effective thermal insulators and limit the efficient dissipation of heat. Therefore, placing blotting cells in a coldroom is not an adequate means of controlling transfer buffer temperature. The use of additional cooling devices, such as the cooling coil or Bio-IceTM units, is required for high-intensity field transfers and is recommended for long unsupervised runs
Assembling the Gel and Membrane Sandwich
Each gel sandwich will contain the gel and membrane sandwiched between pieces of blot absorbent filter paper (Figure 3.1). To prevent contamination, always wear gloves when handling the gels, membranes, and filter paper.
Optional gel/cassette assembly trays are available for the CriterionTM blotter and Trans-Blot® Plus cell (see Ordering Information). These trays are large enough to accommodate the gel holder cassette during sandwich assembly.
6. For each gel, cut one piece of membrane and two pieces of filter paper to the dimensions of the gel. Precut membranes and filter papers are available (see Ordering Information).
7. Equilibrate the membranes in transfer buffer.
· Membranes must be thoroughly wetted in transfer buffer prior to assembly of the gel and membrane sandwich. Nitrocellulose membranes may be wetted directly with transfer buffer, while PVDF membranes must be thoroughly soaked in 100% methanol before being soaked in transfer buffer
8. Place a fiber pad on top of the black side of the cassette, submerged in buffer. Push on the fiber pad with gloved fingertips to thoroughly wet the pad.
9. Place a piece of filter paper on top of the fiber pad (it should be wetted immediately).
10. Gently place the preequilibrated gel on top of the filter paper. Run a wet, gloved finger across the gel to remove any air bubbles that may be trapped underneath the gel.

26 Protein Blotting Guide

Performing the Transfer

Chapter 3

11. Carefully place the preequilibrated membrane on top of the gel. Make sure the membrane is correctly positioned as it touches the gel. To avoid ghost prints and other artifacts, do not move the membrane after it is positioned. Use the roller to remove any air bubbles and to ensure proper contact between the gel and membrane.
12. Wet a second piece of filter paper in transfer buffer and place it on top of the membrane. 13. Soak a fiber pad in transfer buffer and place it on top of the filter paper. 14. Once the cassette is closed and locked, insert it into the tank with the latch side up.
Make sure the black cassette plate faces the black electrode plate.
Performing the Transfer
15. Add transfer buffer to the tank until the buffer level reaches the fill line. 16. Place the lid on top of the cell, making sure that the color-coded cables on the lid are
attached to the electrode cards of the same color. Reversing the orientation of the cables will cause irreversible damage to the plate electrodes. 17. Connect the cables to the power supply and begin the run. See Chapter 2 and the instruction manual for suggested run times with various buffers. · Initial test runs should be used to evaluate the transfer efficiency at various field
strengths (V/cm), staying within the recommended guidelines of each instrument. Transfers under high power should be monitored carefully and cooling used when indicated · An initial test run should be performed to determine the time required for complete transfer. Times vary from 15 min to overnight and depend on many factors, including the power setting, the size and shape of the protein, etc. 18. Upon completion of the run, remove the cassettes and disassemble the gel and membrane sandwich. Rinse the membrane briefly in ddH2O to ensure that no residual gel pieces or sample adhere to the membrane.
Performing a Semi-Dry Transfer
Preparing the Transfer Buffer and Gels
1. Prepare the transfer buffer in amounts that will suffice for gel equilibration, sandwich assembly, and electrophoresis. See the Appendix for buffer formulations.
2. Rinse gels briefly in ddH2O and equilibrate for 15 min in transfer buffer. · All gels should be equilibrated in transfer buffer to remove contaminating electrophoresis buffer salts. If salts are not removed, they will increase the conductivity of the transfer buffer and the amount of heat generated during the transfer. Also, gels will shrink or swell to various degrees in the transfer buffer depending on the acrylamide percentage and the buffer composition. Equilibration allows the gel to adjust to its final size prior to electrophoretic transfer. Equilibration is not necessary when the same buffer is used for both electrophoresis and transfer (for example, native gel transfers)

Protein Blotting Guide 27

Chapter 3

Performing the Transfer

1
2
3 4 5 6
7
8
9
Fig. 3.2. Transfer assembly for the Trans-Blot SD semi-dry transfer system. 1. Safety lid 2. Cathode assembly with latches 3. Filter paper 4. Gel 5. Membrane 6. Filter paper 7. Spring-loaded anode platform
mounted on four guideposts 8. Power cables 9. Base

Assembling the Gel and Membrane Sandwich
Each gel sandwich will contain the gel and membrane sandwiched between one to three pieces of blot absorbent filter paper (Figure 3.2).
· If extra thick filter paper is used, only one sheet on each side will be necessary
· If thick or thin filter paper is used, two or three sheets on each side of the gel must be used, respectively
The amount of filter paper used for semi-dry transfers is important because the filter paper serves as the only reservoir for the transfer buffer. To prevent contamination, always wear gloves when handling the gels, membranes, and filter paper.
3. For each gel, cut one piece of membrane and two to six pieces of filter paper to the dimensions of the gel. Precut membranes and filter papers are available (see Ordering Information).
4. Soak the filter paper in transfer buffer.
5. Equilibrate the membranes in transfer buffer.
· Membranes must be thoroughly wetted in transfer buffer prior to assembly of the gel and membrane sandwich. Nitrocellulose membranes may be wetted directly with transfer buffer, while PVDF membrane must be thoroughly soaked in 100% methanol before being soaked in transfer buffer
6. Remove the safety cover and stainless-steel cathode assembly.
7. Place a presoaked sheet of extra thick filter paper onto the platinum anode. Roll a pipet or roller over the surface of the filter paper (like a rolling pin) to push out all air bubbles. If thick or thin filter paper is used instead, repeat with one or two more sheets of buffersoaked paper.
8. Carefully place the presoaked membrane on top of the filter paper. Roll out all air bubbles.
9. Gently place the preequilibrated gel on top of the membrane, aligning the gel on the center of the membrane. Transfer will be incomplete if any portion of the gel is outside of the membrane. The membrane and filter paper should be cut to the same size as the gel. Remove all air bubbles.
· To avoid ghost prints and other artifacts, do not move the membrane and/or gel after it is positioned. Use the roller to remove any air bubbles and to ensure proper contact between the gel and membrane
10. Wet a second piece of presoaked extra thick filter paper on top of the membrane. Roll a pipet or roller over the surface of the filter paper to push out all air bubbles. If thick or thin filter paper is used instead, repeat with one or two more sheets of buffer-soaked paper. Wipe up any excess buffer around the gel/membrane sandwich to prevent current leaks.
11. Carefully place the cathode onto the stack.
12. Place the safety cover back onto the unit.
Performing the Transfer
13. Connect the cables to the power supply and begin the run. See Chapter 2 and the instruction manual for suggested run times with various buffers.
14. Upon completion of the run, remove the cathode assembly and disassemble the gel and membrane sandwich. Rinse the membrane briefly in ddH2O to ensure that no residual gel pieces or sample adhere to the membrane.

28 Protein Blotting Guide

Performing the Transfer

Chapter 3

Microfiltration
Microfiltration with the Bio-Dot® and Bio-Dot SF involves presoaking the transfer membrane as described, assembly of the transfer apparatus, application of the vacuum, and application of the sample. Detailed protocols are provided in the Bio-Dot and Bio-Dot SF instruction manuals. Some advice for microfiltration transfers is provided below.
Application of the Vacuum
Apply the vacuum only until solutions are removed from the sample wells, then adjust the flow valve so that the unit is exposed only to atmospheric pressure and disconnect the vacuum. For best sample binding, the entire sample should be filtered by gravity flow without vacuum.
During the assay, do not leave the unit with the vacuum on. This may dehydrate the membrane and may cause halos around the wells.
Proper Drainage
Proper positioning of the flow valve relative to the level of the apparatus is important for proper drainage. The speed of drainage is determined by the difference in hydrostatic pressure between the fluid in the sample wells and the opening of the flow valve that is exposed to the atmosphere. When the flow valve is positioned below the sample wells, proper drainage may be achieved.
Flow Valve -- Extended Incubations
If a prolonged or overnight incubation is desired, adjust the flow valve so that the vacuum manifold is closed off from both the vacuum source and atmosphere before applying the samples. In this configuration, solutions will remain in the sample wells with less than a 10% loss of volume during extended incubations.
Flow Valve -- Gentle Vacuum
To apply a gentle vacuum to the apparatus, adjust the flow valve so that it is open to the atmosphere, the vacuum source, and the vacuum manifold while the vacuum is on. Then, use a finger to cover the valve port that is exposed to the atmosphere. The pressure of your finger on the valve will regulate the amount of vacuum reaching the manifold.
Filtering or Centrifugation of Samples
For best results, filter or centrifuge samples to remove particulate matter that might restrict the flow of solutions through the membrane.
Air Bubbles
Air bubbles trapped in the wells will prevent the sample from binding to the membrane. Air bubbles may be removed by gently pipeting the solution up and down.
Membrane Removal
The best method for removing the membrane from the Bio-Dot units is to leave the vacuum on while loosening the screws and removing the sample template. Then, turn off the vacuum and remove the membrane.

Protein Blotting Guide 29

30 Protein Blotting Guide

Chapter 4 Detection

Detection

Detection Methods
Once proteins have been transferred to a membrane, they can be visualized using a variety of specialized detection reagents (Figure 4.1). Protein standards are useful for monitoring transfer efficiency of the experiment and serve as molecular weight markers for calibration of blot patterns. Total protein stains allow visualization of the protein pattern on the blot and immunological detection methods, employing antibody or ligand conjugates, allow visualization of specific proteins of interest. This chapter reviews the various protein standards, total protein stains, and immunological detection methods available.

Immunological Detection

Total Protein Detection

Fig. 4.1. Protein detection systems.

Anionic Dyes

Biotinylation

Colloidal Gold

Fluorescence

Amido Black or Coomassie Blue
R-250

Biotin-BlotTM Kit

Optional Enhancement
Reagents

SYPRO Ruby Protein Blot Stain

500 ng

50 ng

100 pg­1 ng

2­8 ng

Chemiluminescence

Color Development

Other

HRP

AP

HRP

AP

Immun-StarTM HRP

Immun-Star AP

Amplified Opti-4CNTM

Opti-4CN

Immun-Blot® HRP (4CN)

DAB

Immun-Blot AP

Immun-Blot Amplified AP

1­3 pg

10 pg

5 pg

100 pg

500 pg

500 pg

100 pg

10 pg

Autoradiography

Immunogold Labeling

Bioluminescence Chemifluorescence Fluorescence

Protein Blotting Guide 31

Chapter 4

Detection

Protein Standards

Protein standards are mixtures of well-characterized or recombinant proteins and are routinely used in electrophoresis and blotting applications. Protein standards:
· Provide a reference for determining the molecular weight of proteins identified by antibody or ligand probes
· Are useful for monitoring transfer efficiency
· Serve as controls to ensure proper location of transferred bands in repetitive screening experiments
Protein standards are available as either prestained, unstained, or biotinylated sets of purified or recombinant proteins. In general, prestained standards allow easy and direct visualization of their separation during electrophoresis and of their transfer to membranes. Though prestained standards can also be used for estimation of molecular weight of separated proteins, unstained or biotinylated standards are recommended for the most accurate molecular weight determination. Applications of Bio-Rad's blotting standards are summarized in Table 4.1.

Table 4.1. Blotting standard selection guide.

Product Name Prestained Standards Precision Plus Protein dual color standards

Application
· Molecular weight estimation · Assessing transfer efficiency · Monitoring electrophoretic separation

Precision Plus Protein all blue standards

· Molecular weight estimation · Assessing transfer efficiency · Monitoring electrophoretic separation

Precision Plus Protein KaleidoscopeTM standards

· Molecular weight estimation · Assessing transfer efficiency · Monitoring electrophoretic separation

Kaleidoscope prestained standards

· Assessing transfer efficiency · Monitoring electrophoretic separation

Prestained SDS-PAGE standards

· Assessing transfer efficiency · Monitoring electrophoretic separation

Unstained Standards
Precision Plus Protein unstained standards

· Molecular weight determination on blots

Biotinylated standards
SDS-PAGE unstained standards

· Molecular weight determination on blots · Molecular weight determination on blots

Comparative Information
· Sharpest prestained bands · Best for molecular weight estimation · 2 colors plus reference bands · Load-and-go format; no dilution · Recombinant
· Sharpest prestained bands · Best for molecular weight estimation · Blue bands plus reference bands · Load-and-go format; no dilution · Recombinant
· Sharpest prestained bands · Best for molecular weight estimation · 5 bright colors for easy band identification · Load-and-go format; no dilution · Recombinant
· Individually colored proteins · Prestained bands · Available in broad molecular weight and polypeptide ranges · Each lot individually calibrated (molecular weight will vary between lots)
· Economical · Available in low, high, and broad molecular weight ranges · Prestained all blue bands · Each lot individually calibrated (molecular weight will vary between lots)
· Integral Strep-tag sequence allows detection of standards along with antigen of interest (2-step detection)
· Sharpest unstained bands · 10-band, well-spaced ladder
· Simultaneous detection with immunostained antigens · Available in low, high, and broad molecular weight ranges
· Separate detection required using a total protein stain such as colloidal gold, Amido Black, or Ponceau S
· Available in low, high, and broad molecular weight ranges

32 Protein Blotting Guide

Detection

Chapter 4

250 kD 150 100
75
50 37
25 20 15 10

250 kD 150 100
75
50 37
25 20 15 10

250 kD 150 100
75
50 37
25 20 15 10

210 kD
125 101
56.2 35.8 29 21
6.9

113 kD 92 52.9
35.4 29

208 kD
126 97

21.5

48

216 kD 132
78
45.7 32.5
18.4 7.6

36.4 kD 26.6
16 8.4 3.8

Precision Plus Protein
Kaleidoscope Standards
Catalog # 161-0375

Precision Plus Protein
Dual Color Standards
Catalog # 161-0374

Precision Plus Protein All Blue
Standards
Catalog # 161-0373

Prestained SDS-PAGE Standards, Broad Range*
Catalog # 161-0318

* MW may vary from lot to lot

Prestained SDS-PAGE Standards, Low Range*
Catalog # 161-0305

Prestained SDS-PAGE Standards, High Range*
Catalog # 161-0309

Kaleidoscope Prestained Standards,*
Broad Range*
Catalog # 161-0324

Kaleidoscope Polypeptide Standards*
Catalog # 161-0325

Fig. 4.2. Bio-Rad's selection of prestained blotting standards. Bio-Rad's prestained standards are available in low, high, and broad molecular weight ranges.

Prestained Standards for Western Blotting
Bio-Rad provides both recombinant and natural prestained standards. The ability to visualize prestained standards during electrophoresis makes them ideal for monitoring protein separation during gel electrophoresis. The ease in transferring to the blot also make them popular for monitoring transfer efficiency and the general location of antigens in repetitive screening assays (Tsang et al. 1984). This, combined with recent improvements made in their design and manufacture, has made prestained standards an excellent choice for

estimations of molecular weights on western blots. Figure 4.2 and Table 4.2 summarize Bio-Rad's prestained standards.
Recombinant Prestained Standards Advances in molecular biology and genetic engineering have led to the development of recombinant protein standards for electrophoresis. With recombinant technology, specific attributes, such as evenly spaced molecular weights or customization of proteins with affinity tags for easy detection, may be designed and engineered into sets of protein standards. Bio-Rad's recombinant standards are in the Precision Plus Protein standards family.

Table 4.2. Composition and molecular weights (in kD) of prestained standards. A, recombinant prestained standards; B, natural prestained standards.

A

B

Precision Plus Protein Standards Family*

Kaleidoscope Prestained Standards**

Kaleidoscope Polypeptide Standards**

Prestained High Range**

Prestained Low Range**

Prestained Broad Range**

250

202

­

205

­

208

150

133

­

118

­

115

100

­

­

­

107

­

75

71

­

85

76

79.5

50

­

­

47

52

49.5

37

41.8

38.6

­

36.8

34.8

25

30.6

25

­

27.2

28.3

20

15

17.8

16.3

­

19

20.4

10

6.9

7.8

­

­

7.2

­

3.4

­

­

­

* The molecular weights for the Precision Plus Protein family do not vary from lot to lot. ** The molecular weights for the natural prestained standards are from a representative lot of standards; they will vary from lot to lot.

Protein Myosin
-Galactosidase Phosphorylase b BSA Ovalbumin Carbonic anhydrase Soybean trypsin inhibitor Lysozyme Aprotinin Insulin

Protein Blotting Guide 33

Chapter 4

Detection

log MW

Fig. 4.3. Exceptional linearity of Precision Plus ProteinTM standards. The standard curve was generated by plotting the log molecular weight (MW) versus the migration distance (Rf) of each protein standard band through an SDS-PAGE gel. Precision Plus Protein Kaleidoscope standards showed r2 = 0.996, demonstrating a very linear standard curve.

2.5

2.0

1.5

1.0

0.5

0.0

0.2

0.4

0.6

0.8

1.0

Rf

Fig. 4.4. Bio-Rad's unstained and biotinylated protein blotting standards. The biotinylated standards were detected with avidin-AP and BCIP/NBT color development reagents.

Precision Plus Protein Prestained Standards Precision Plus Protein prestained standards are a blend of ten recombinant proteins and provide a ten-band, broad range molecular weight ladder (10­250 kD) with single (all blue), dual (dual color), or multicolored (Kaleidoscope) protein bands (Figure 4.2). The colors allow easy band referencing and blot orientation. Because the proteins in the Precision Plus Protein standards are recombinant, and the staining technology is optimized, their molecular weight does not vary from lot to lot. Dye labeling can be controlled more effectively, delivering homogeneous staining and tight, sharp bands. All Precision Plus Protein prestained standards (all blue, dual color, Kaleidoscope) deliver the most linear (r2 >0.995) standard curve available for prestained standards (Figure 4.3). As a result, these standards may be used for highly accurate estimation of molecular weight across a broad size range.

Natural Prestained SDS-PAGE Standards Natural molecular weight standards are blended from naturally occurring proteins, often providing a familiar band pattern. Although very effective for monitoring gel separation and transfer efficiency, they have an inherent variability in the amount and location of dye that covalently binds to the protein. This may produce broader bands than seen in recombinant prestained standards or in unstained standards, making them less desirable for molecular weight estimations.
Kaleidoscope Standards Kaleidoscope prestained standards contain individually colored proteins that allow instant band recognition on western blots or gels. The molecular weights of the proteins in each lot are calibrated against unstained SDS-PAGE standards. The Kaleidoscope standards are available in broad or low molecular weight (polypeptide) formulations; polypeptide standards are designed for use with Tricine gels when resolving small proteins and peptides.
Prestained SDS-PAGE Standards Naturally occurring prestained SDS-PAGE standards are available in specific size ranges: low, high, and broad.

250 kD
150
100 75 50 37
25 20 15 10

200 kD
116.3 97.4 66.2
45
31 21.5 14.4 6.5

97.4 kD 66.2 45
31
21.5 14.4

200 kD 116.3
97.4 66.2
45

26.6 kD
17.0 14.4 6.5
3.5 1.4

97.4 kD 66.2 45
31
21.5
14.4

200 kD
116.3 97.4 66.2
45

200 kD
116.3 97.4 66.2
45
31
21.5 14.4
6.5

200 kD
116.3 97.4 66.2
45
31 21.5 14.4 6.5

97.4 kD 66.2 45 31
21.5 14.4

200 kD 116.3
97.4 66.2
45

Precision Plus Protein
Unstained Standards

Unstained SDS-PAGE Standards, Broad Range

Catalog # 161-0363

Catalog # 161-0317

SDS-PAGE Standards, Low Range
Catalog # 161-0304

SDS-PAGE Standards, High Range

Polypeptide SDS-PAGE Standards

Catalog # 161-0303

Catalog # 161-0328

Silver Stain SDS-PAGE Standards, Low Range
Catalog # 161-0314

Silver Stain SDS-PAGE Standards, High Range
Catalog # 161-0315

SDS-PAGE Standards,
SYPRO Orange, Broad Range Catalog # 161-0332

Biotinylated SDS-PAGE Standards, Broad Range
Catalog # 161-0319

Biotinylated SDS-PAGE Standards, Low Range
Catalog # 161-0306

Biotinylated SDS-PAGE Standards, High Range
Catalog # 161-0311

34 Protein Blotting Guide

Detection

Chapter 4

Table 4.3. Composition and molecular weights (in kD) of unstained standards. A, recombinant unstained standards; B, natural unstained standards.

A

B

Precision Plus Protein Unstained Standards

Low Range

SDS-PAGE and Biotinylated Standards

High Range

Broad Range

Protein

250

­

200

200

Myosin

150

­

116.25

116.25

-Galactosidase

100

97.4

97.4

97.4

Phosphorylase b

75

66.2

66.2

66.2

BSA

50

45

45

45

Ovalbumin

37

31

­

31

Carbonic anhydrase

25

21.5

­

21.5

Soybean trypsin

20

inhibitor

15

14.4

­

14.4

Lysozyme

10

­

­

6.5

Aprotinin

Unstained Standards for Western Blotting
Bio-Rad provides recombinant, natural, and biotinylated unstained standards. Since unstained standards contain only the protein itself, they do not exhibit the variability in molecular weight that is often seen with prestained standards. Therefore, unstained standards, biotinylated standards, or standards with an affinity tag for blot detection deliver almost 100% molecular weight accuracy across a linear curve and are recommended for the most accurate molecular weight determinations for gels or blots. Figure 4.4 and Table 4.3 summarize the composition and molecular weights of Bio-Rad's unstained standards.
Precision Plus Protein Unstained Standards Precision Plus Protein unstained standards provide a recombinant ten-band, broad range molecular weight ladder (10­250 kD). These standards contain an affinity Strep-tag peptide that displays an intrinsic binding affinity towards StrepTactin, a genetically modified form of streptavidin. It is the high-affinity binding of the Strep-tag sequence to StrepTactin that allows convenient and simultaneous detection of both proteins and standards on western blots (Figure 4.5) using either colorimetric or chemiluminescent methods.

Add StrepTactin-AP or -HRP conjugate
Add substrate
Substrate converted to colored compound

Individual Precision Plus Protein standard with integrated Strep-tag sequence

Fig. 4.5. Overview of the StrepTactin detection system.

StrepTactin conjugate binds Strep-tag sequence

Colorless substrate comes in contact with StrepTactin-AP or -HRP conjugate
Standard band is visualized by AP or HRP enzymatic conversion of substrate to colored compound

Protein Blotting Guide 35

Chapter 4

Detection

E

E EE

E

Standards lane
Sample lane
Antigen Biotin Avidin Antibodies E HRP or AP (enzyme)
Fig. 4.6. Detection of biotinylated standards. Following transfer and addition of antigen-specific primary antibody, avidin-HRP or avidin-AP is added to the conjugated secondary antibody solution and applied to the membrane. Avidin binds to the biotinylated standards while the secondary antibody binds to the primary antibody. The standards and the protein of interest are detected simultaneously using the appropriate color development reagent system.

Biotinylated Standards Biotinylated protein standards have been developed specifically for accurate molecular weight determinations in blotting applications (Della-Penna et al. 1986). These proteins have been treated with a limited amount of biotin. Since biotin is a relatively small molecule, the mobilities of the standard proteins in SDS-PAGE gels are not altered. The biotinylated proteins form sharp, tight bands with well-defined molecular weights and are processed simultaneously with the immunostained antigens. Therefore, they provide fast, accurate, reproducible determinations of antigen molecular weights directly on the membrane. Bio-Rad's biotinylated standards are available in three molecular weight ranges.
Biotinylated standards are easily detected using avidin or streptavidin conjugated with horseradish peroxidase (avidin-HRP) or alkaline phosphatase (avidin-AP) (Figure 4.6).

Unstained SDS-PAGE Standards The protein markers used for SDS-PAGE gels form very tight bands that transfer reproducibly to membranes. Molecular weight determination with these proteins, however, may require cutting the lane of standards from the membrane and using a separate total protein stain for identification. After visualization, the cut strip must be realigned with the probed membrane. If anionic dye is used to stain the strip of standards, the dye solvent may shrink nitrocellulose membrane, making it necessary to measure Rf values and calculate molecular weight information. Alternatively, the entire blot may be stained with a washable anionic total protein dye like Ponceau S (see Anionic Dyes, below) and the positions of the standards on the blot marked with a pencil. SDS-PAGE standards are available in three molecular weight ranges.

Total Protein Staining

Total protein staining of a membrane provides a visual image of the complete protein pattern. This information is required for the full characterization of specific antigens detected in a complex protein mixture. Since SDS-PAGE gels shrink during staining procedures, comparison of an immunologically probed membrane to a stained gel is not practical. Instead, the

exact location of a specific antigen in relation to other proteins is determined by comparing two blotted membranes, one of which has been probed with an antibody and the other stained for total protein. Table 4.4 compares the advantages and disadvantages of several total protein staining techniques.

Table 4.4. Comparison of total protein staining methods.

Method Anionic dyes Colloidal gold (enhanced) Biotinylation Fluorescence

Sensitivity 100­1,000 ng 1 ng (10­100 pg) 50 ng 2­8 ng

Advantages Inexpensive, rapid Very sensitive, rapid; optional enhancement increases detection sensitivity Sensitive assay Mass spectrometry compatible

Disadvantages Low sensitivity; shrinks membrane Expensive
Results fade with time UV fluorescence detection system required

36 Protein Blotting Guide

Detection

Chapter 4

Anionic Dyes
The first techniques developed for total protein staining of blotted membranes used the same anionic dyes commonly used for staining proteins in polyacrylamide gels. Dyes that became popular for detecting proteins bound to membranes include Amido Black (Towbin et al. 1979), Coomassie Brilliant Blue R-250 (Burnette 1981), Ponceau S, and Fast Green FCF (Reinhart and Malamud 1982). Of the anionic dyes used, Amido Black and Ponceau S are the best choices because they destain rapidly in distilled water or low concentrations of methanol and produce very little background staining. Coomassie Brilliant Blue gives high background staining, even after long destaining procedures. Fast Green is not tightly bound to the proteins, so the dye can be easily removed after visualization to allow subsequent immunological probing.
These dyes are easy to prepare and they stain proteins quickly, but they are relatively insensitive when compared to immunological detection assays. The stains that require alcohol-containing solutions (for example, Amido Black, Coomassie Brilliant Blue, Fast Green FCF) for solubility can shrink nitrocellulose membranes, making direct comparison of an immunologically detected antigen to the total protein on the stained membrane difficult. Amido Black 10B and Coomassie Blue R-250 are available from Bio-Rad.

Colloidal Gold
An alternative to anionic dyes that provides detection sensitivities that rival those of immunological detection methods is colloidal gold (Moeremans et al. 1987, Rohringer and Holden 1985). When a solution of colloidal gold particles is incubated with proteins bound to a nitrocellulose or PVDF membrane, the gold binds to the proteins through electrostatic adsorption. The resulting gold-protein complex produces a transient, reddish-pink color due to the optical properties of colloidal gold. This gold-protein interaction is the basis for total protein staining with colloidal gold as well as for specific, immunogold detection (see Immunogold Detection below).
Silver enhancement of the colloidal gold signal produces a stable, dark brown reaction product and enhances sensitivity down to 10 pg of protein. The method of silver enhancement makes use of the fact that gold particles can reduce silver ions in solution; this reduction leads to deposition of the silver on top of the gold and the effective growth of the metallic particle. Since methanol is not required, colloidal gold with silver enhancement has the advantage over the anionic dyes of not shrinking the membrane during staining. Exact comparisons between membranes stained for total protein and membranes used for immunological detection are possible.
Bio-Rad's colloidal gold total protein stain is provided ready to use with an optional gold enhancement kit. Alternatively, the colloidal gold stain and silver enhancement kit are available as components of the enhanced colloidal gold total protein detection kit.

Protein Blotting Guide 37

Chapter 4

Detection

Biotinylation
Bio-Rad's Biotin-Blot total protein detection kit provides a sensitive total protein detection method that takes advantage of the highaffinity binding of avidin to biotin. This method uses NHS-biotin to biotinylate all proteins on the membrane surface, followed by incubations with an avidin-horseradish peroxidase (avidin-HRP) conjugate and the HRP color-development reagent to detect the biotinylated proteins. The assay is 10­50 times more sensitive than the anionic stains, and does not require methanol. Exact comparison of the immunologically detected membranes and membranes stained for total protein is possible.

Fluorescence
Fluorescent protein stains like SYPRO Ruby, SYPRO Red, SYPRO Orange, and Deep Purple provide highly sensitive detection of proteins on blots as well as in gels. SYPRO Ruby protein blot stain allows detection as low as 2­8 ng. After staining, target proteins can be detected by colorimetric or chemiluminescent immunodetection methods, or analyzed by microsequencing or mass spectrometry with no interference from the protein stain.

Immunological Detection Systems

Transfer

Block unbound membrane sites

Incubate wth primary antibody

Wash

Incubate wth conjugated secondary antibody or ligand

Wash

Develop signal based on color or chemiluminescence

Documentation and analysis of results
Fig. 4.7. Basic immunological detection procedure.

Immunological detection systems are used to identify specific proteins blotted to membranes. Though there are numerous systems available for immunological detection, the basic procedure for these assays varies very little.
The basic steps for immunological detection of a specific protein in a blot are summarized in Figure 4.7. After the proteins have been transferred to the membrane, the membrane is blocked, incubated with a primary antibody, washed, incubated with a secondary antibody, and washed again. The primary antibody is specific for the protein of interest, and the secondary antibody enables its detection (Figure 4.8). The secondary antibody can be radiolabeled, labeled with a

fluorescent compound or gold particles, or conjugated to an enzyme like AP or HRP. For many years, radiolabeled secondary antibodies were the method of choice for detection, but newer methods have evolved that are less hazardous and easier to use than radioactivity, yet maintain the same degree of sensitivity. Available detection methods now include -- in addition to autoradiography of radiolabeled probes -- colorimetric, chemiluminescent, bioluminescent, chemifluorescent, fluorescent, and immunogold detection.

38 Protein Blotting Guide

Detection

Chapter 4

Blocking Reagents
Following transfer, unoccupied binding sites on the membranes must be blocked to prevent nonspecific binding of probes; failure to adequately saturate the membrane can lead to high background, since many probes are also proteins, and can also bind to the membrane.
A variety of blocking reagents are available, including gelatin, nonfat milk, and bovine serum albumin (BSA), which are compared in Table 4.5. It is often useful to optimize the detection system for minimal background with no loss of signal by testing several blocking agents. The type of membrane will also affect the selection of blocker. Formulations for the different blocking solutions are available in the Appendix of this manual.
Antibody Incubations
An antibody is a protein that is synthesized by an animal in response to exposure to a foreign substance, or antigen. Antibodies (also called immunoglobulins) have specific affinity for the antigens that elicited their synthesis.
A typical experimental system utilizes two layers of antibody in the detection procedure. The primary antibody is directed against the target antigen; the antigen may be a ligand on a protein, the protein itself, a specific epitope on a protein, or a carbohydrate group. The secondary antibody is specific for the primary antibody; it is usually conjugated to an enzyme such as alkaline phosphatase (AP) or horseradish peroxidase

(HRP), and an enzyme-substrate reaction is part of the detection process (Figure 4.8).
Antibody incubations are generally carried out in antibody buffer containing Trisbuffered saline with Tween (TTBS) and a blocking reagent. Various formulations of antibody buffer are provided in the Appendix of this manual.
Primary Antibodies The primary antibody recognizes and binds to the target antigen on the membrane. For incubations with primary antibody, the entire blot must be covered with antibodycontaining solution. The appropriate concentration or dilution (titer) of the primary antibody must be determined empirically for each new lot of primary antibody.
The optimal antibody concentration is usually considered to be the greatest dilution of antibody still resulting in a strong positive signal without background or nonspecific reactions. Generally, when serum or tissue culture supernatants are the source of primary antibody, a 1:100­ 1:1,000 dilution of the primary antibody in buffer is used. Chromatographically purified monospecific antibodies may be used at dilutions of 1:500­1:10,000, and a 1:1,000­1:100,000 dilution may be used when ascites fluid is the source of antibody. The Mini-PROTEAN® II multiscreen apparatus and mini incubation trays described at the end of this chapter are useful tools for determining antibody titer.

S 4
P
3
2
1
Fig 4.8. Specific enzymatic detection of membrane-bound antigens. 1, gelatin blocks unoccupied sites on the membrane; 2, primary antibody to a specific antigen is incubated with the membrane; 3, a blotting grade antibody-enzyme conjugate is added to bind to the primary antibody; 4, substrate reagent is then added to the blot. The enzyme catalyzes the substrate (S) to form a detectable product (P) at the site of the antigen-antibody complex.

Table 4.5. Comparison of blocking reagents.

Blocking Reagent
Gelatin
Nonfat dry milk, BLOTTO, blottinggrade blocker
BSA

Membrane Compatibility Nitrocellulose Nitrocellulose, PVDF

Recommended Concentration 1­3% 0.5­5%

Nitrocellulose, PVDF 1­5%

Tween 20

Nitrocellulose

0.05­0.3%

Notes Requires heat to solubilize PVDF requires higher concentrations of nonfat milk than nitrocellulose
PVDF requires higher concentrations of BSA than nitrocellulose May strip some proteins from the blot

Protein Blotting Guide 39

Chapter 4

Detection

Species-Specific Secondary Antibodies Blotting-grade species-specific secondary antibodies are the detection reagents of choice. Secondary antibodies are specific for the isotype (class) and the species of the primary antibody (for instance, a goat antirabbit secondary antibody is an antibody generated in goat for detection of a rabbit primary antibody). Secondary antibodies bind to multiple sites on primary antibodies to increase detection sensitivity.
Secondary antibodies can be labeled and detected in a variety of ways. The antibody can be linked to a fluorescent compound or to gold particles, but most commonly the antibody is conjugated to an enzyme, such as HRP or AP. If the secondary antibody is biotinylated, biotin-avidin-HRP or -AP complexes can be formed. Addition of a suitable enzyme substrate results in production of a colored precipitate or fluorescent or chemiluminescent product through oxidation (by HRP) or dephosphorylation (by AP).
Since the purity of the reagents is critical to the success of the experiment, sera must be affinity purified to obtain only those antibodies directed against the particular IgG. Otherwise, background staining and false positive reactions due to nonspecific antibody binding may occur. The purified antibody solution should be cross-adsorbed

against an unrelated species; for example, human IgG for anti-rabbit and anti-mouse antibodies, and bovine IgG for anti-human reagents, to remove antibodies that are not specific for the species of interest. Because blotting grade antibodies are directed to both heavy and light chains of the IgG molecules, the reagents can be used to identify IgM- and IgA-class antibodies as well as all subtypes of IgG antibodies.
Secondary antibodies are generally used at dilutions of ~1:3,000.
Antibody-Specific Ligands Protein A and protein G are bacterial cell surface proteins that bind to the Fc regions of immunoglobulin molecules (Akerstrom et al. 1985, Boyle and Reis 1987, Goding 1978, Langone 1982). The advantage of using protein A or protein G is their ability to bind to antibodies of many different species (Table 4.6). This is often desirable for laboratories using antibody probes from many different species or using one of the less common primary antibody systems in their experiments; that is, rat, goat, or guinea pig. In addition, these reagents only bind to antibody molecules; this can reduce the background from nonspecific binding of antibodies to membrane-bound proteins when a low-titer, poorly purified second antibody is used. The major limitation of protein A and protein G conjugates is their

Table 4.6. Immunoglobulin-binding specificities of protein A and protein G.

Immunoglobulin
Human IgG1 Human IgG2 Human IgG3 Human IgG4 Mouse IgG1 Mouse IgG2a Mouse IgG2b Mouse IgG3 Rat IgG1 Rat IgG2a Rat IgG2b Rat IgG2c

Protein A
   
--
  
     

--
   

Protein G
       
      
  
  

Immunoglobulin
Pig IgG
Rabbit IgG
Bovine IgG1 Bovine IgG2 Sheep IgG1 Sheep IgG2 Goat IgG1 Goat IgG2 Horse IgG(ab) Horse IgG(c) Horse IgG(t) Dog IgG

Protein A
  
--
 
--
     
--
 

  = Strong binding  = Weak binding -- = No binding

Protein G
                   
 

40 Protein Blotting Guide

Detection

Chapter 4

lower sensitivity. Because only one ligand molecule binds to each antibody, the enhancement of a multiple-binding detection system, such as a species-specific polyclonal antibody, is lost. Generally, the species-specific antibody is 10­50 times more sensitive than the ligand reagent when the same detection system is used.
Washes
Between the two antibody incubations and prior to detection, the blot must be washed to remove excess antibody to prevent nonspecific binding. Though the washing solutions and times may vary, depending on the antibodies and detection systems used, washes generally utilize tris-buffered saline (TBS) or TBS with additional detergent (Tween 20; TTBS). Note that the addition of detergent may inhibit certain detection reactions -- see the instruction manuals for details. Wash buffer formulations are described in the Appendix of this manual.
Detection Methods
Blotted proteins are generally detected using secondary antibodies that are labeled with radioisotopes or colloidal gold, or conjugated to fluorophores, biotin, or an enzyme like HRP or AP. Early blotting systems used 125I-labeled reagents similar to those used in radioimmunoassay. These systems provide sensitive results, but the special handling and disposal problems of 125I reagents have discouraged continued use of this technique. Instead, a number of enzyme systems and detection reagents evolved (Figure 4.9 and Table 4.7).
By far, the most commonly used detection methods use secondary antibodies conjugated to HRP or AP. With these systems, when the enzyme substrate is added, either a colored precipitate is deposited on the blot (colorimetric detection) or a chemiluminescent or fluorescent product is formed (chemiluminescent and chemifluorescent detection) and the light signal is captured on film or with a CCD or fluorescence imager.
Colorimetric Detection Enzymes such as AP and HRP convert several substrates to a colored precipitate. As the precipitate accumulates on the blot, a colored signal develops that is visible on the blot (Figure 4.9A). The enzyme reaction can be monitored and stopped when the desired signal over background is produced. Colorimetric detection is easier to use than any film-based detection method, which must be developed by trial and error, and uses costly materials such as X-ray film and darkroom chemicals.
Colorimetric detection is typically considered a medium-sensitivity method, compared to radioactive or chemiluminescent detection.

A. Colorimetric detection

Target protein
Primary antibody
Secondary antibody
Enzyme conjugate Substrate Product Label (radiolabel or fluorophore) Emitted light or radiation Precipitate

B. Chemiluminescence C. Bioluminescence D. Chemifluorescence

Fig. 4.9. Mechanisms of detection chemistries. In each method of western blot detection, a detectable signal is generated following binding of an antibody specific for the protein of interest. In colorimetric detection (A), the signal is a colored precipitate. In chemiluminescent (B) and bioluminescent (C) detection, the reaction itself emits light. Chemiluminescent and bioluminescent detection are distinguished by the source of the substrate. In chemifluorescent detection (D), the product is fluorescent. Fluorescent detection, autoradiography, and immunogold detection record the signal generated by a labeled secondary antibody. In fluorescent detection, the antibody is labeled with a fluorophore, while in autoradiography, it is labeled with a radioactive isotope (E). In immunogold detection (F), the secondary antibody is labeled with gold, and signal is generally enhanced by silver precipitation.

E. Fluorescence/ autoradiography
Au

F. Immungold detection

Protein Blotting Guide 41

Chapter 4

Detection

Table 4.7. Comparison of detection reagent systems.

Sensitivity

HRP
500 pg (4CN and DAB) 1­3 pg (Immun-StarTM HRP)

Substrates
Comparative cost Stability of stored blots Restrictions

4CN -- purple DAB -- brown Luminol -- emits light
Least expensive
Poor for 4CN and DAB Good for Immun-Star kits
Azide inhibits peroxidase activity

AP 100 pg (Immun-Blot®) 10 pg (Immun-Star AP) 10 pg (Immun-Blot amplified AP) BCIP/NBT -- purple CDP-Star -- emits light
More expensive Good
Endogenous phosphatase activity also detected

However, Bio-Rad has colorimetric systems that offer very high sensitivity equal to detection by chemiluminescence (Table 4.8).
Colorimetric HRP Systems Colorimetric HRP systems were the first enzyme-conjugates used for immunological detection of blotted proteins. The advantage of HRP systems was that both the enzyme conjugate and colorimetric detection substrates were economical. The most common color substrates for HRP are 4-chloro-1-naphthol (4CN) (Hawkes et al. 1982) and 3,3'-diaminobenzidine (DAB) (Tsang et al. 1985) (Figure 4.10). HRP colorimetric detection systems are not as

sensitive as AP colorimetric detection systems. Fading of blots upon exposure to light, inhibition of HRP activity by azide, and nonspecific color precipitation are additional limitations of HRP colorimetric detection systems.
Opti-4CN Substrate and Detection Kits
Colorimetric HRP detection with 4CN presents very low background and a detection sensitivity of about 500 pg of antigen. Bio-Rad's Opti-4CN kit improves this detection sensitivity to 100 pg. Opti-4CN is available as a premixed substrate kit or combined with an HRPconjugated antibody in a detection kit.

Table 4.8. Colorimetric detection systems.

Detection Method

Detection Substrate Sensitivity Signal Color Product Options

Colorimetric HRP 4CN

500 pg

Purple

· Dry powder, liquid substrate, Immun-Blot kits

Advantages
· Fast color development, low cost, low background

DAB

500 pg

Brown

· Dry powder

· Fast color development, low background

Opti-4CN 100 pg
Amplified 5 pg Opti-4CN

Purple Purple

Colorimetric AP

BCIP/NBT 100 pg
Amplified 10 pg BCIP/NBT

Purple Purple

· Liquid substrate, Opti-4CN kit
· Amplified Opti-4CN kit
· Dry powder, liquid substrate, Immun-Blot kits
· Amplified AP Immun-Blot kit

· High sensitivity, nonfading color, low background
· Best sensitivity available; no extra materials (such as X-ray film) needed
· Stable storage of data
· High sensitivity

Disadvantages
· Results fade over time; azide inhibits enzyme activity
· More safety precautions than for other substrates
· Azide inhibits enzyme activity
· More expensive than 4CN
· More steps than unamplified protocol
· Detects endogenous phosphatase activity
· More steps than unamplified protocol

42 Protein Blotting Guide

Detection

Chapter 4

H2N H2N
HN·+ H2N
HN·+ H2N

DAB

HRP + H2O2

HRP­O

N·· H2

­1e­

NH2

NH + HRP­O·· + H2O

NH2 ­1e­ Quinone iminium cation radical

NH Polymerization to complex brown precipitate

NH2

n

4CN OH
CI HRP + H2O2

Fig. 4.10. Colorimetric detection options with HRP. DAB and 4CN are commonly used chromogenic substrates for HRP. In the presence of H2O2, HRP catalyzes the oxidation of the substrate into a product that is visible on a blot. Left, reaction with DAB; right, reaction with 4CN.

H2O O

Insoluble purple product H CI

Amplified Opti-4CN Substrate and Detection Kits
Amplified Opti-4CN substrate and detection kits are based on proprietary HRP-activated amplification reagents from Bio-Rad. These kits allow colorimetric detection to 5 pg, which is comparable to or even exceeds the sensitivity that is achieved with radiometric or chemiluminescence systems, without the cost or time involved in darkroom development of blots.
Immun-Blot HRP Assay Kits
Immun-Blot assay kits provide the reagents required to perform standard HRP/4CN colorimetric detection on western blots with the added convenience of premixed buffers and enzyme substrates.

Premixed and Individual HRP Colorimetric Substrates
Premixed enzyme substrate kits and development reagents, including powdered 4CN and DAB color development reagents, are also available. The premixed kits are convenient and reliable and reduce exposure to hazardous reagents used in the color development of protein blots.

Protein Blotting Guide 43

Chapter 4

Detection

Colorimetric AP Systems Colorimetric AP systems use soluble 5-bromo-4-chloro-3-indolyl phosphate (BCIP) and Nitroblue Tetrazolium (NBT) as substrates to produce a stable reaction product that will not fade (Figure 4.11). AP can be easily inactivated by exposure to acidic solutions. Multiple probing of the same membrane with alternative antibody probes is easily performed using substrates that produce different colors, such as blue and red (Blake et al. 1984, Turner 1983).

Fig. 4.11. AP colorimetric

development. In the colorimetric

system, AP catalyzes the substrates

BCIP and NBT to produce a colored

precipitate visualizing the protein

on a western blot. First the

dephosphorylation of BCIP by AP occurs, yielding a bromochloro

Br

indoxyl intermediate. The indoxyl is

then oxidized by NBT to produce an

indigoid dye (purple precipitate). The

NBT is also reduced by the indoxyl,

opening the tetrazole ring to

produce an insoluble diformazan

(blue precipitate). The combination

of the indigoid dye of the BCIP and

the insoluble formazan of the NBT

forms a purple-blue colored

precipitate.

BCIP ONa

O P ONa

CI

O

N H AP + H2O
­ OPO32­

CI

O

Br

2

N BC indoxyl intermediate H

H+ H
­O N+

CI

O

O

Br

H N

N+ N C
NN
O

Immun-Blot AP Assay Kits
The Immun-Blot AP assay kits provide the essential reagents to perform colorimetric detection on western blots with the added convenience of premixed buffers and enzyme substrates. All kit components are individually quality-control tested in blotting applications. Included in each kit is an instruction manual with a thoroughly tested protocol and troubleshooting guide that simplifies immunological detection.
Immun-Blot Amplified AP Kit
Increased sensitivity in western blot experiments can be achieved by utilizing an amplified AP procedure (Bayer and Wilchek 1980, Chaiet and Wolf 1964, Guesdon et al. 1979, Hsu et al. 1981). This detection system begins by using a biotinylated secondary antibody. Relying on the specific binding properties of biotin and avidin, a complex of streptavidin and biotinylated AP is then added to the membrane. Because streptavidin will bind more than one molecule of biotin, the initial site of the primary antibody-to-antigen binding is

NBT

N N+ C
NN
O

N+ O­ O

N

H

O

Indigoid dye

(purple precipitate)

Br CI

­O N+ O

NN

H

C

NN

O

NN

C

H

NN

O

Insoluble diformazan (blue precipitate)

N+ O­ O

44 Protein Blotting Guide

Detection

Chapter 4

effectively converted into multiple AP binding sites available for color development (Figure 4.12). Color development is performed using conventional AP substrates, as discussed previously. The Immun-Blot amplified AP kit increases the detection sensitivity of colorimetric western blotting to 10 pg of protein.
Premixed and Individual AP Colorimetric Substrates
Premixed enzyme substrate kits are convenient and reliable and reduce exposure to hazardous reagents.

CDP-Star
OO O CH3

CI

OPO3Na2

AP + H2O CI

Chemiluminescent Detection Chemiluminescence is a chemical reaction in which a chemical substrate is catalyzed by an enzyme, such as AP or HRP, and produces detectable light as a by-product (Figures 4.9B, 4.13, and 4.14A). The light signal can be captured on X-ray film, or by a charge-coupled device (CCD) imager such as the VersaDocTM and ChemiDocTM systems.
This technology is easily adapted to existing western blotting procedures because chemiluminescence uses enzymeconjugated antibodies for the activation of the light signal. The blocking and wash methods are familiar procedures.
Luminol NH2 O
NH
NH
O HRP + H2O2

S3 P

1

2

Fig. 4.12. Immun-Blot amplified AP kit.
1. Biotinylated secondary antibody binds to primary antibody.
2. Complex of streptavidin and biotinylated-AP binds to biotin of secondary antibody.
3. Multiple APs are available to convert substrate (S) to colored precipitate (P).

­ OPO32­

OO O CH3

CI

O­

CI

OO

O CH3

*

+

O­

CI

CI Product in excited state

Light emission

NH2 O­

O N Peroxy O N intermediate

O­

NH2

*

COO­

Product in excited state

COO­

Light

Fig. 4.13. Chemiluminescent detection. The secondary antibody is linked to an enzyme, which catalyzes a reaction leading to light emission. Left, CDP-Star or another 1,2-dioxetane AP substrate is dephosphorylated by AP, resulting in formation of an excitedstate anion that emits light. Right, luminol oxidized by HRP in the presence of H2O2 leads to formation of a 3-aminophthalate dianion and the release of light.

Protein Blotting Guide 45

Chapter 4

Detection

Table 4.9. Chemiluminescence detection systems.

Detection Method Chemiluminescent HRP

Substrate Luminol

Detection Sensitivity
1­3 pg

Chemiluminescent AP

CDP-Star

10 pg

Product Options · Conjugates · HRP substrate · Immun-Blot kits
· Conjugates · AP substrate · Immun-Blot kits

Advantages
· Short (30 sec) exposure · Signal duration 6­8 hr · Compatible with PVDF
and nitrocellulose · Working solution stable for
24 hr at room temperature
· 30 sec to 5 min exposure · Signal continues for 24 hr
after activation · Blot can be reactivated

Disadvantages · Azide inhibits enzyme activity
· Endogenous phosphatase activity may lead to false positives

Fig. 4.14. Detection of CDK7 and Precision Plus ProteinTM unstained standards using the Immun-Star HRP chemiluminescent detection kit. A, proteins and 0.5 µl of standards (lane 1) and a dilution series of a HeLa cell lysate (lanes 2­6) were electrophoresed on a 4­20% CriterionTM gel and transferred to a nitrocellulose membrane. The optimal amount of standards to load on the blot was first determined using a dilution series. The blot was probed with an antibody specific for human CDK7 followed by an HRP-conjugated secondary antibody and StrepTactin-HRP conjugate. After a 2 min incubation in the Immun-Star HRP detection solution, the blot was exposed to film for 5 sec. B, proteins from an identical gel, except with 10 µl of standards, were stained with Bio-SafeTM Coomassie stain (catalog #161-0786) to visualize total protein.

A
1
B
1

2

3

4

5

6

2

3

4

5

6

The advantages of chemiluminescent western blotting over other methods are its speed and sensitivity (Table 4.9). This method is perfect for CCD imaging, which avoids the slow film step. Exposure times with average blots are usually 30 sec to 5 min. This is a large improvement over 125I systems, which can require up to 48 hr for

film exposure. Detection of protein down to low picogram amounts is typical of these systems. This is more sensitive than most colorimetric systems, and approximately equal to radioisotopic detection. The detection sensitivity is dependent on the affinity of the protein, primary antibody, and secondary antibody and can vary from one sample to another.
Safety is another advantage of chemiluminescent detection. It does not have the disadvantages related to isotope detection, such as exposure of personnel to radiation, high disposal costs, and environmental concerns.
Immun-Star Chemiluminescent Western Blotting Kits Immun-Star kits include either CDP-Star substrate, which is activated by AP, or luminol, which is activated by HRP. The Immun-Star kits produce a strong signal on either nitrocellulose or PVDF. The light signal generated with Immun-Star kits not only gives a fast exposure, but also lasts for as long as 24 hr (Immun-Star AP kit) after initial activation of the blot. These blots can also be reactivated with fresh substrate, even weeks after the signal has been depleted (Figure 4.14). They can also be stripped and reprobed multiple times.

46 Protein Blotting Guide

Detection

Chapter 4

De-ExposeTM Background Remover for X-Ray Film De-Expose background remover allows removal of background from overexposed X-ray film. It can be used for film-based chemiluminescent detection as well as in any application that uses X-ray film exposure. De-Expose background remover can fix background problems regardless of cause, whether overexposure of film, insufficient or incorrect blocking solution, contaminated transfer buffer, impure antibodies, or incorrect antibody or probe dilution. The kit also removes speckles and corrects the intensity of overloaded bands (Figure 4.15).
Other Detection Methods
Bioluminescence Bioluminescence is the natural phenomenon of light emission by many organisms. Bioluminescent systems differ in the structure and function of enzymes and cofactors involved in the process as well as the mechanism of the light-generating reactions.
Bioluminescence is also used as a detection method for proteins and nucleic acids on a membrane. Bioluminescent detection involves incubation of the membrane (with bound antigen-antibody-enzyme complex) in a bioluminogenic substrate and simultaneous measurement of emitted light (Figure 4.9C). The substrate involved in this detection system is a luciferin-based derivative. Light detection is performed using a photoncounting camera and the blotted proteins are visualized as bright spots.
This technique is similar to chemiluminescence in its sensitivity and speed of detection but it is not widely used and few bioluminogenic substrates are commercially available. PVDF is the preferred membrane for bioluminescent detection because nitrocellulose membranes may contain substances that inhibit luciferase activity.

Chemifluorescence Chemifluorescence is the enzymatic conversion of a substrate to a fluorescent product. Fluorogenic compounds (nonfluorescent or weakly fluorescent substances that can be converted to fluorescent products) are available to use with a wide variety of enzymes, including AP and HRP. The enzyme cleaves a phosphate group from a fluorogenic substrate to yield a highly fluorescent product (Figure 4.9D). The fluorescence can be detected using a fluorescence imager such as the Molecular Imager FXTM Pro Plus system or VersaDocTM system and quantitated using Quantity One® software. Chemifluorescence can provide a stable fluorescent reaction product, so that blots can be scanned at a convenient time. The method is compatible with standard stripping and reprobing procedures.
Fluorescence In fluorescent detection (Figure 4.9E), the secondary antibody is labeled with a fluorophore such as fluorescein (FITC), Texas Red, rhodamine (TRITC), or R-phycoerythrin. The main advantage of fluorescent detection is that it can provide a 10-fold greater linear dynamic range with only 2- to 4-fold reduced sensitivity over chemiluminescent detection. Fluorescent western blot detection can therefore provide better linearity and better quantitation within the detection limits. Fluorescent detection also allows multiplexing. Multiplexing with different colored fluorophores allows simultaneous detection of several target proteins on the same blot.
Autoradiography The gamma-emitting radioisotope 125I can be used to label the ­NH2 group of lysines in immunoglobulins for radiometric antigen detection. Direct immunological detection (using labeled secondary antibodies) of as little as 1 pg of dotted immunoglobulin is possible with high specific activity 125I probes. Radiolabeled blots can be detected using X-ray film, a method known as autoradiography (Figure 4.9E).

Before

After

Overloaded bands

Before

After

Overexposed film
Figure 4.15. Before and after images demonstrate the effectiveness of De-Expose background remover.

Protein Blotting Guide 47

Chapter 4

Detection

Immunogold Labeling Immunogold detection methods utilize goldlabeled secondary antibodies for antigen detection. Because this method has relatively low sensitivity and the signal is not permanent, silver enhancement methods similar to those described above for colloidal gold total protein stains were developed as a means of enhancing the signal. With silver enhancement, a stable dark brown signal with little background is produced on the blot (Figure 4.9F), and sensitivity is increased 10-fold, equivalent to colorimetric AP detection and several times more sensitive than autoradiography.
Imaging -- Documentation and Analysis Methods
Several methods are employed for the documentation of western blotting results: X-ray film or digital charge-coupled device (CCD) camera imaging for luminescent signals, CCD or laser-based imaging systems for the capture and documentation of fluorescent and colorimetric signals, and X-ray film or phosphor imagers for radiolabeled samples (Table 4.10).

Luminescent Detection For chemiluminescent detection methods, CCD imaging is the easiest, most accurate, and rapid method. Traditionally, the chemiluminescent signal from blots has been detected by X-ray film. The popularity of chemiluminescence has led to development of special films with enhanced sensitivity to the blue wavelengths of light emitted by the chemiluminescent substrates. Film is a sensitive medium to capture the chemiluminescent signal but suffers from a sigmoidal response to light that has a narrow linear region, which limits its dynamic range. To gather information from a blot, which has both intense and weak signals, it is necessary to perform multiple exposures to produce data for all samples in the linear range of the film. A process termed preflashing can improve linearity, but this requires extra equipment and effort. Additionally, quantitation of data collected by exposure to film requires digitization (that is, scanning of X-ray film with a densitometer).

Table 4.10. Comparison of western blot documentation and analysis methods.

Film

Densitometry

Exposure Time

Dynamic range

1.8

3.0

(orders of magnitude)

Linear response through- No

Yes

out dynamic range

Cost

Initial investment of processor plus recurring consumable expenses

Initial investment of densitometer

Detection Method

Bioluminescent

No

No

Chemiluminescent

Yes

No

Chemifluorescent

No

No

Fluorescent

No

No

Colorimetric

No

Yes

Autoradiography

Yes

No

Detection System

N/A

GS-800TM

CCDs
2­4.8
Yes
Initial investment of imaging system
Yes Yes Yes Yes Yes No ChemiDoc XRS or VersaDoc 4000/5000

Laser-Based Systems
4.8
Yes
Initial investment of imaging system
No No Yes Yes Yes Yes Molecular Imager FX Pro Plus

48 Protein Blotting Guide

Detection

Chapter 4

A CCD camera is capable of capturing data with a linear response over a broad dynamic range. The linear dynamic range of CCD systems is 2­4.8 orders of magnitude, depending on the bit depth of the system. CCD systems also offer convenience by providing a digital record of experiments for data analysis, sharing, and archiving, and by eliminating the need to continually purchase consumables for film development. Another advantage of the CCD camera is its ability to approach the limit of signal detection in a relatively short time. For example, the VersaDoc 5000 imaging system can reach the limit of detection of a given experiment in less than one minute. For the same experiment, Kodak Bio-Max film requires about 30 min to reach the same limit of detection.
Fluorescent, Chemifluorescent, and Colorimetric Detection Fluorescent, chemifluorescent, and colorimetric detection all benefit from the advantages of digital imaging -- convenience, digital records of experiments, sensitive limit of detection, and wide dynamic range. Fluorescent and chemifluorescent signals can be detected with a wide range of imaging systems including both CCD and laser-based technologies. For example, the VersaDoc and Molecular Imager FX Pro Plus systems can be used similarly to detect fluorescent and chemifluorescent signals. The decision to use one type of technology over another will depend on budget and requirements for limit of detection and resolution. CCD systems are generally less expensive than laser-based systems. While the dynamic range of CCD imaging systems varies from 2 to 4.8 orders of magnitude, laser-based systems do not provide a choice of dynamic ranges but do provide the widest dynamic range (4.8 orders of magnitude) available. The resolution of CCD and laser-based systems is similar, with the finest resolution settings generally being 50 µm or less.

Another advantage of fluorescent and chemifluorescent detection is that CCD and laser-based detection limits generally far exceed the dynamic ranges of the fluorescent assays currently used for protein detection.
Colorimetric samples can be easily recorded and analyzed with a densitometer such as the GS-800 calibrated densitometer. The densitometer provides a digital record of the blot, excellent resolution, reproducible results, and accurate quantitation. The GS-800 also uses red-, green-, and bluecolor CCD technology to greatly improve the detection of a wide range of colorimetric detection reagents.
Autoradiography To detect the commonly used radioisotopes, 35S, 32P, 33P, 12C, and 125I, the most widely used method is autoradiography on X-ray film. Autoradiography provides a good combination of sensitivity and resolution without a large investment. For direct autoradiography without intensifying screens or scintillators, the response of the film is linear only within a range of 1­2 orders of magnitude. When intensifying screens or fluorographic scintillators are used to increase sensitivity, the response of the film is nonlinear, but it can easily be made linear by preexposing the film to a flash of light. Phosphor imagers, such as Bio-Rad's Molecular Imager FX Pro Plus multiimager, offer an alternative to film detection methods. The initial investment in instrumentation offers increased sensitivity and dynamic range compared to X-ray film, and exposure times are 10 to 20 times shorter than those for film. The ability to accurately quantitate data is also much greater with storage phosphor screens because the linear dynamic range of phosphor imagers is significantly greater, 4.8 orders of magnitude, enabling accurate quantitation and the elimination of overexposure and saturated signals.

Protein Blotting Guide 49

Chapter 4

Detection

Table 4.11. Multiscreen apparatus specifications.

Membrane size (W x L) Number of sample templates Channels per template Sample volume per channel Dimensions (W x L x H)

8 x 7 cm 2 20 200­600 µl 27 x 11 x 6 cm

Fig. 4.16. Mini incubation tray.
Fig. 4.17. Multiscreen apparatus.

Screening Apparatus
In some experiments, protein blots need to be screened for a number of different antigens or under a number of different conditions. Mini incubation trays allow screening of individual strips that have been cut from blots. The Mini-PROTEAN® II multiscreen apparatus allows screening of a single blot with up to 40 different antibodies or sera without cutting the blot into individual strips.
Mini Incubation Trays Mini incubation trays allow safe, simple, and economical screening of different antigens on protein blot strips. Each tray has eight 10.5 cm x 5 mm channels to accommodate strips cut from a particular protein blot. Because the trays are disposable, the potential contamination associated with washing reusable trays is eliminated. Unique ribs in the tray lids combine with the overall design of the sample channels to ensure that no crosscontamination occurs (Figure 4.16).

Mini-PROTEAN® II Multiscreen Apparatus When proteins are resolved by SDS-PAGE and blotted onto a membrane for analysis, the Mini-PROTEAN II multiscreen apparatus simplifies the screening process. Instead of being cut into individual strips for incubation, the entire blot is simply clamped into the multiscreen unit for assay. Two separate, detachable sample templates allow up to 40 different antibody or serum samples to be screened. The unique molded gasket ensures a leakproof seal, preventing crosscontamination between samples (Table 4.11 and Figure 4.17).

50 Protein Blotting Guide

Chapter 5
Troubleshooting

Troubleshooting

Transfer

Detection

Electrophoretic Transfer . . . . . . . . . . . . . . . . . . . . . . . 52
Poor Electrophoretic Transfer Swirls or Missing Patterns; Diffuse Transfers Gel Cassette Pattern Transferred to Blot Poor Binding to the Membrane -- Nitrocellulose Poor Binding to the Membrane -- PVDF
Blotting Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Missing Bands Molecular Weight Assignments for Natural (Nonrecombinant) Prestained Standards Differ From Lot to Lot A Protein's Molecular Weight Differs From Expected Molecular Weight Variation in Mobility Between Recombinant and Natural Prestained Standards of the Same Molecular Weight
Microfiltration Blotting . . . . . . . . . . . . . . . . . . . . . . . . 56
Leakage or Cross-Well Contamination Uneven Filtration or No Filtration Halos Around the Wells

Immunological Detection . . . . . . . . . . . . . . . . . . . . . . 57
Overall High Background Nonspecific Reactions Between Bound Proteins and Probes No Reaction or Weak Signal Tests for Monitoring Reagent Activity
Multiscreen Apparatus . . . . . . . . . . . . . . . . . . . . . . . . 59
Leakage or Cross-Well Contamination Bubbles Trapped Within the Channels Halos Around the Wells
Total Protein Detection . . . . . . . . . . . . . . . . . . . . . . . . 59
Colloidal Gold Total Protein Stain -- High Background Colloidal Gold Total Protein Stain -- Low Sensitivity Biotin-BlotTM Total Protein Detection -- High Background Biotin-Blot Total Protein Detection -- No Reaction or Weak Color Development Anionic Dyes -- High Background Anionic Dyes -- Low Sensitivity

Protein Blotting Guide 51

Chapter 5

Troubleshooting

Transfer
Electrophoretic Transfer
Poor Electrophoretic Transfer 1. Transfer time was too short.
· Increase the transfer time (thicker gels require longer transfer time) 2. Power conditions were inappropriate.
· Always check the current at the beginning of the run. The current may be too low for a particular voltage setting. If the buffer is prepared improperly, the conductivity may be too low, and not enough power will be delivered to the cell. See the power guidelines for specific applications in Chapter 2
· Remake the buffer or increase the voltage · Try the high-intensity blotting option · Make sure the power supply being used has a high current limit. If an incorrect power
supply is used, it is possible to not reach the set voltage if the current of the power supply is at its maximum limit 3. Proteins were transferred through the membrane. · If the power conditions are set too high, or the transfer run too long, proteins may be transferred through the membrane and into the filter paper. See "Poor Binding to the Membrane" for hints on how to improve binding 4. Proteins moved in the wrong direction. · The gel/membrane sandwich may have been assembled in the wrong order or the cassette inserted in the tank in the wrong orientation. Check the polarity of the connections to the power supply 5. The detection system is not working or is not sensitive enough. · Include proper positive and negative control antigen lanes to test for kit sensitivity; consult kit manual · Stain the gel after transfer with a total protein stain such as Coomassie Blue, Bio-SafeTM Coomassie, or SYPRO Ruby to make sure that proteins have left the gel 6. The charge-to-mass ratio is incorrect (native transfers). · Try a more basic or acidic transfer buffer to increase protein mobility. Proteins near their isoelectric points will be transferred poorly (buffer pH should be 2 pH units higher or lower than the pI of the protein of interest for optimal transfer efficiency) 7. Protein precipitated in the gel. · Use SDS in the transfer buffer. SDS can increase transfer efficiency, but note that it can also reduce binding efficiency to nitrocellulose and affect reactivity of some proteins with antibodies · Reduce or eliminate the amount of alcohol in the transfer buffer 8. Methanol in the transfer buffer is restricting elution. · Reducing the amount of methanol results in increased transfer efficiency of proteins from the gel, but it also decreases binding to nitrocellulose membranes; 20% methanol is generally optimal for protein binding 9. The power supply circuit is inoperative, or an inappropriate power supply was used. · Check the fuse and make sure the voltage and current output of the power supply match the needs of the blotting instrument · Check the output capacity of the power supply
52 Protein Blotting Guide

Troubleshooting

Chapter 5

10. The gel percentage was too high. · Reduce %T (total monomer) or %C (crosslinker). Using 5%C (with bis-acrylamide as the crosslinker) will produce the smallest pore size gel. Decreasing this concentration will increase the pore size and increase transfer efficiency
Swirls or Missing Patterns; Diffuse Transfers 1. Contact between the membrane and the gel was poor. Air bubbles or excess buffer
remain between the blot and gel. · Carefully move the roller over the membrane in both directions until air bubbles or
excess buffer are removed from between gel and membrane, and complete contact is established · Use thicker filter paper in the gel/membrane sandwich · Replace the fiber pads. Pads will compress and degrade with time, and will not hold the membrane to the gel
2. Power conditions were inappropriate. · Always check the current at the beginning of the run. The current may be too high for a particular voltage setting. If the buffer is prepared improperly, the conductivity may be too high, resulting in excessive power delivered to the cell and overheating. See the power guidelines for specific applications in Chapter 2
3. The membrane was not properly wetted or had dried out. · White spots on the nitrocellulose membrane indicate dry areas where protein will not bind. If wetting does not occur immediately by immersion of the sheet in transfer buffer, heat distilled water until just under the boiling point, and soak the membrane until completely wet. Equilibrate in transfer buffer until ready for use · Because of the hydrophobic nature of PVDF, the membrane must be prewet in methanol prior to equilibration in aqueous transfer buffer. Follow the directions in the product insert
4. Poor gel electrophoresis. · Artifacts of electrophoresis may occur as a result of poor gel polymerization, inappropriate running conditions, contaminated buffers, sample overload, etc. Consult your electrophoresis manual for more details
Gel Cassette Pattern Transferred to Blot 1. Contaminated or thin fiber pads were used.
· Replace the fiber pads, or thoroughly clean the contaminated pads
2. Excessive amounts of protein were loaded on the gel, or too much SDS was used in the transfer buffer. Proteins can pass through the membrane without binding, and recirculate through the tank blotting system. · Reduce the amount of protein on the gel, and the SDS in the transfer buffer. Add a second sheet of membrane to bind excess protein
3. The transfer buffer was contaminated. · Make fresh solutions
Poor Binding to the Membrane -- Nitrocellulose 1. The methanol concentration in the transfer buffer was not optimal.
· Make sure the buffer contains the proper amount of methanol -- 20% is generally optimal for protein binding
2. Proteins passed through the nitrocellulose. · Use PVDF or 0.2 µm nitrocellulose (smaller pore size). Decrease the voltage if using the high-intensity option
Protein Blotting Guide 53

Chapter 5

Troubleshooting

54 Protein Blotting Guide

· Place an additional piece of nitrocellulose membrane in the gel sandwich and analyze this added piece for evidence of proteins that may have been transferred completely through the first piece
3. Proteins with molecular weight <15,000 may show decreased binding to 0.45 µm nitrocellulose, or may be washed from the membrane during assays. · Use PVDF or nylon membrane, which have higher binding capacities · Use 0.2 µm nitrocellulose · Use Tween 20 detergent in the wash and antibody incubation steps. Reduce or eliminate the more stringent washing conditions
4. SDS in the transfer buffer reduces the binding efficiency of proteins. · Reduce or eliminate the SDS from the transfer buffer
5. The membrane was not completely wet. · White spots on the membrane indicate dry areas where protein will not bind. If wetting does not occur immediately on immersion of the sheet in transfer buffer, heat distilled water until just under the boiling point, and soak the membrane until it is completely wet. Equilibrate in transfer buffer until ready for use
6. Contact between the membrane and the gel was poor. Air bubbles or excess buffer remain between the blot and gel. · Carefully move the roller over the membrane in both directions until air bubbles or excess buffer are removed from between gel and membrane, and complete contact is established · Use thicker filter paper in the gel/membrane sandwich · Replace the fiber pads. Pads will compress and degrade with time, and will not hold the membrane to the gel
Poor Binding to the Membrane -- PVDF 1. The membrane was not completely wet.
· Because of the hydrophobic nature of PVDF, the membrane must be completely soaked in methanol prior to equilibration in aqueous transfer buffer. Follow the directions in the product insert
2. The membrane was allowed to dry during handling. · A completely wet membrane has a gray, translucent appearance. A membrane that has been allowed to dry will show white spots. Since proteins will not bind to the dry spots, rewet the membrane with methanol and reequilibrate in transfer buffer
3. Proteins passed through the membrane. · Decrease the voltage if transferring under high-intensity conditions · Place a second piece of PVDF membrane in the gel sandwich and analyze this piece for evidence of proteins that may have been transferred completely through the first membrane · Reduce transfer time
4. SDS in the transfer buffer reduces the binding efficiency of proteins. · Reduce or eliminate the SDS from the transfer buffer
5. Contact between the membrane and the gel was poor. Air bubbles or excess buffer remain between the blot and gel. · Carefully move the roller over the membrane in both directions until air bubbles or excess buffer are removed from between gel and membrane, and complete contact is established · Use thicker filter paper in the gel/membrane sandwich · Replace the fiber pads. Pads will compress and degrade with time, and will not hold the membrane to the gel

Troubleshooting

Chapter 5

Blotting Standards
Missing Bands 1. Transfer was incomplete.
· See "Poor Electrophoretic Transfer" for suggestions on how to enhance transfer efficiency
2. Gel used can only resolve part of the molecular weight range of the standard used. · Use the standard with the appropriate molecular weight range for protein of interest gel concentration
3. Detection was poor using biotinylated standards. · See "No Reaction or Weak Signal" for suggestions on how to enhance detection
Molecular Weight Assignments for Natural (Nonrecombinant) Prestained Standards Differ From Lot to Lot 1. Addition of the dye causes proteins to migrate differently from their true molecular weight,
and their apparent molecular weight can vary by as much as 10%. · The molecular weights of the standards in each lot of prestained and KaleidoscopeTM
standards are calibrated against Bio-Rad's Precision Plus ProteinTM unstained standards. The lot-specific molecular weight information is included in every vial to roughly estimate the molecular weight of sample proteins
A Protein's Molecular Weight Differs From Expected Molecular Weight 1. The protein is posttranslationally modified.
· Posttranslational modifications of natural proteins, such as the addition of carbohydrate units, phosphorylation, and hydroxylation, will alter both the mass and the mobility of proteins
2. The protein contains an unusual proportion of basic or acidic amino acids. · The primary amino acid composition may affect a protein's mobility. A protein with a large number of basic amino acids residues such as lysine, arginine, or histidine (including His tags or patches) will migrate at a higher apparent molecular weight than anticipated, compared to a recombinant protein of the same molecular weight. For instance, lysozyme, a protein containing many lysine residues, will migrate more slowly than other proteins of the same molecular weight. Conversely, proteins with a net negative charge due to the presence of glutamate or aspartate residues will migrate more quickly, resulting in a lower apparent molecular weight
3. Previous estimates of the molecular weight of the protein were made using a different standard. · Due to differences in protein composition between standards, the r2 values for two standards will not be identical. Using different standards to estimate the molecular weight of an unknown protein at different times, or to compare one protein to another, can produce different results. Once an unknown protein is calibrated to a particular protein standard, the same standard should be used for all subsequent molecular weight estimations

Protein Blotting Guide 55

Chapter 5

Troubleshooting

Variation in Mobility Between Recombinant and Natural Prestained Standards of the Same Molecular Weight 1. The amino acid composition of the protein standards is different.
· Due to differences in protein composition between standards, the r2 values for two standards will not be identical. Using different standards to estimate the molecular weight of an unknown protein at different times, or to compare one protein to another, will lead to different conclusions. Once an unknown protein is calibrated to a particular protein standard, that standard should be used for molecular weight estimation
· In order to most accurately determine molecular weight, mass spectrometry should be used to confirm molecular weight estimation by gel analysis. This is a common, hightechnology application that gives the precise molecular weight of any protein
Microfiltration Blotting
Leakage or Cross-Well Contamination 1. The instrument was assembled incorrectly.
· The screws must be retightened under vacuum following initial assembly to form a proper seal
2. The membrane was not rehydrated after assembly. · Rehydrate the membrane prior to loading samples. Apply vacuum only until solutions are removed from the sample wells, then disconnect the vacuum
Uneven Filtration or No Filtration 1. The membrane became clogged with particulates.
· Centrifuge samples or filter solutions prior to application to remove particulates 2. The flow valve was positioned higher than the apparatus.
· The flow valve must be lower than the level of the sample wells or drainage will not occur
3. Bubbles obstructed the flow of liquid. · Use a needle to carefully break any bubbles, being careful not to puncture the membrane · Pipet liquid up and down to displace the bubbles
4. Improper blocking or antibody buffers were used. · Gelatin clogs the membrane; BSA or Tween 20 can be substituted for gelatin in the detection procedure
5. Fluid pressure was not uniform. · Seal off unused wells or add solution to unused wells
Halos Around the Wells 1. The membrane was not rehydrated after assembly.
· Rehydrate the membrane prior to loading samples. Apply vacuum only until solutions are removed from the sample wells, then disconnect the vacuum
2. Too much protein was loaded, overloading the capacity of the membrane. · Determine optimal loading conditions by performing serial dilutions of samples
3. The blocking step was too short. · Make sure blocking step is as long as the longest incubation period
4. Loading volume was too low. · The meniscus contacted the center of the well causing uneven distribution of protein sample. The minimum loading volume is 100 µl
56 Protein Blotting Guide

Troubleshooting

Chapter 5

Detection
Immunological Detection
Overall High Background 1. Blocking was incomplete.
· Match the blocker to the membrane. For example, PVDF membranes require more extensive blocking, usually with nonfat milk
· Increase the concentration or blocking time as necessary · The blocker must be a pure protein. The blocker may be contaminated with material
that binds probes nonspecifically
2. Insufficient wash protocols were used. · Increase the number, duration, or stringency of the washes. Include progressively stronger detergents in the washes; for example, SDS is stronger than Nonidet P-40 (NP-40), which is stronger than Tween 20. Also, include Tween 20 in the antibody dilution buffers to reduce nonspecific binding
3. The blot was left in the substrate too long. · Remove the blot from the substrate solution when the signal-to-noise level is acceptable. Do not overdevelop. Stop the reaction immediately by immersing the blot in ddH2O
4. Contamination occurred during electrophoresis or transfer. · Discard and remake the gel and transfer solutions · Replace or thoroughly clean contaminated fiber pads if a tank blotter was used
5. Excessive amounts of protein were loaded on the gel, or too much SDS was used in the transfer buffer. Proteins can pass through the membrane without binding and recirculate through a tank blotting system. · Reduce the amount of protein on the gel or SDS in the transfer buffer. Add a second sheet of membrane to bind excess protein
6. The primary or secondary antibody was too concentrated. · Increase the dilution of the antibodies. Perform a dot-blot experiment to optimize the working concentrations
7. The incubation trays were contaminated. · Clean the trays or use disposable trays
Nonspecific Reactions Between Bound Proteins and Probes 1. The primary or secondary antibody is contaminated with nonspecific IgG or with IgG
cross-reactive between species. · Use purified IgG primary antibody fractions and affinity-purified blotting-grade
secondary antibody
2. Monoclonal antibodies may have reacted nonspecifically with SDS-denatured proteins. · Compare the binding of other monoclonal or polyclonal antibodies · Blot native proteins as a comparison
3. Nonspecific interactions are occurring due to ionic associations. For example, avidin, a glycosylated protein, may bind to more acidic proteins on blots. · Increase the ionic strength of the incubation buffers. Increase the number, duration, or stringency of the washes. Include progressively stronger detergents in the washes; for example, SDS is stronger than Nonidet P-40 (NP-40), which is stronger than Tween 20. Include Tween 20 in the antibody dilution buffers to reduce nonspecific binding

Protein Blotting Guide 57

Chapter 5

Troubleshooting

No Reaction or Weak Signal 1. The sample load was insufficient.
· Increase the amount of protein applied · Concentrate the sample prior to loading · Use a more sensitive assay system
2. Antigen binding to the membrane was insufficient. · Stain the gel after transfer or use prestained or Kaleidoscope standards to assess transfer efficiency. See the previous section for suggestions on improving transferrelated problems
3. Antigen denaturation occurred during electrophoresis or transfer. · Antibodies, especially monoclonals, may not recognize denatured antigens · Electrophorese and transfer proteins under native conditions. Use the super cooling coil and a refrigerated recirculating bath to transfer heat-sensitive proteins
4. The primary or secondary antibody was inactive or nonsaturating. · Store the reagents at recommended conditions. Avoid repeated freeze-thaw cycles, bacterial contamination, and heat inactivation · Detergents may affect the binding of some antibodies. Eliminate them from the assay, except for the wash after blocking · If the antibody titer is too low, optimize the concentration using a dot-blot experiment · Increase the antibody incubation times
5. The enzyme conjugate was inactive or nonsaturating. · Test the reagent for activity (see below) · Store the reagents at recommended conditions. Avoid repeated freeze-thaw cycles, bacterial contamination, and heat inactivation · Sodium azide is a potent inhibitor of horseradish peroxidase. Use thimerosal as a bacteriostat · Undistilled water may cause inactivation of the enzyme. Use only distilled, deionized water · If the conjugate concentration is too low, optimize using a dot-blot experiment
6. The color development reagent was inactive. · Test the reagent for activity (see below) and remake if necessary
Tests for Monitoring Reagent Activity 1. Test the activity of the color development solution.
· Combine 1.0 ml of the color development solution with 10 µl of full-strength secondary antibody conjugate. The color reaction should occur immediately. If color fails to develop within a few minutes, the color development solution is inactive. Make up a fresh working solution and repeat the color development assay
2. Test the activity of the conjugate solution. · Combine 1.0 ml of the color development solution tested above and 1.0 ml of the 1:3,000 dilution conjugate solution. A light-blue tinge should develop within 15 min. · If color fails to develop within 25 min, the conjugate solution is suspect. Repeat the procedure with a freshly prepared dilution of conjugate
3. Test the activity of the first antibody solution. · Use an ELISA, RID, Ouchterlony immunodiffusion, or precipitation test to determine reactivity of the antibody with the antigen. If possible, repeat the assay procedure with a more concentrated primary antibody solution

58 Protein Blotting Guide

Troubleshooting

Chapter 5

Multiscreen Apparatus
Leakage or Cross-Well Contamination 1. The instrument was assembled incorrectly.
· Tighten the screws using a diagonal crossing pattern to ensure uniform pressure on the membrane surface. Do not overtighten, because this will cause the channels to cut into the membrane
2. The sample template has warped and can no longer provide a proper seal. (Heating the apparatus to >50°C will warp the acrylic plates.)
Bubbles Trapped Within the Channels 1. Tilt the instrument backwards during sample application to help bubbles rise to the top.
· Slow and careful delivery of reagent also prevents trapping bubbles inside the channels
Halos Around the Wells 1. The membrane was not rehydrated after assembly.
· Rehydrate the membrane prior to loading samples. Apply vacuum only until solutions are removed from the sample wells, then disconnect the vacuum
2. Too much protein was loaded, overloading the capacity of the membrane. · Determine optimal loading conditions by performing serial dilutions of samples
3. The blocking step was too short. · Make sure blocking step is as long as the longest incubation period
Total Protein Detection
Colloidal Gold Total Protein Stain -- High Background 1. The blocking step was insufficient or was omitted.
· Block with 0.3% Tween 20 in TBS, using 3 washes of 20 min each
2. Contamination of the membrane occurred at a previous step; electrophoresis or transfer. · Discard and remake the gel and transfer solutions · Replace or thoroughly clean contaminated fiber pads if a tank blotter was used
3. Excessive amounts of protein were loaded on the gel, or too much SDS was used in the transfer buffer. Proteins can pass through the membrane without binding and recirculate through a tank blotting system. · Reduce the amount of protein on the gel or SDS in the transfer buffer. Add a second sheet of membrane to bind excess protein
4. The colloidal gold stain solution was contaminated. · The stain is a reusable reagent. Be sure to use a separate, clean plastic container to store previously used reagent in the refrigerator. Discard any reagent that has a viscous sediment at the bottom of the bottle. If the solution is no longer a dark burgundy but a light blue, the stain has been contaminated with buffer salts. Buffer salts will react with the gold sol causing nonspecific precipitation of the reagent onto the membrane. Discard this solution
Colloidal Gold Total Protein Stain -- Low Sensitivity 1. The incubation time was insufficient.
· Increase the incubation time for detection of low-level signals. Overnight incubation is possible, although background staining can increase
2. Transfer was incomplete. · See "Poor Electrophoretic Transfer" for suggestions on how to enhance transfer efficiency

Protein Blotting Guide 59

Chapter 5

Troubleshooting

60 Protein Blotting Guide

3. The stain was exhausted, as evidenced by the loss of the dark burgundy color and longer staining times. · Discard the reagent
4. Buffer salt contamination has occurred; the solution is light blue instead of dark burgundy. · Discard the reagent
5. The sample load was too low for the reagent to detect. · Use the gold enhancement kit for detection as sensitive as 10 pg of protein per band
Biotin-BlotTM Total Protein Detection -- High Background 1. The membrane was left in the color development solution too long.
· Remove the membrane from the color development solution when the signal is apparent and no background has developed. Transfer the blot to distilled water immediately to stop development
2. Excessive amounts of protein were loaded on the gel, or too much SDS was used in the transfer buffer. Proteins can pass through the membrane without binding and recirculate through a tank blotting system. · Reduce the amount of protein on the gel or SDS in the transfer buffer. Add a second sheet of membrane to bind excess protein
Biotin-Blot Total Protein Detection -- No Reaction or Weak Color Development 1. Transfer was incomplete.
· See "Poor Electrophoretic Transfer" for suggestions on how to enhance transfer efficiency
2. The sample load was too low for the reagents to detect. · Increase the amount of protein loaded on the gel
3. The NHS-biotin solution was inactive. · NHS-biotin hydrolyzes in aqueous solutions. Equilibrate the reagent vial to room temperature before opening to prevent condensation of water inside the container. To prevent contamination, use a sterile syringe to remove reagent · Add the NHS-biotin reagent to the borate-Tween solution just prior to use
4. Amine-containing buffer salts competed for the biotinylation reagents. · Wash the membrane thoroughly in borate-Tween to remove any residual buffer salts from electrophoresis and transfer
5. The avidin-HRP conjugate was inactive. · Follow the reagent activity test procedures to determine whether reagent is inactive
6. The color development solution was inactive. · Follow the reagent activity test procedures to determine whether reagent is inactive
Anionic Dyes -- High Background 1. Destaining was insufficient.
· Increase the number and duration of washes with the destaining solution
2. The dye solution was too concentrated. · Remake the solution
Anionic Dyes -- Low Sensitivity 1. Anionic dye stains do not detect protein bands below ~100 ng.
· Use a more sensitive stain such as the colloidal gold stain or the Biotin-Blot protein detection kit
· Increase the sample load to achieve a similar staining intensity to that of the anionic dye stains

Appendices
Transfer Buffer Formulations. . . . . . . . . . . . . . . . . . . . 62
Detection Buffer Formulations . . . . . . . . . . . . . . . . . . 63
General Detection Buffers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 Total Protein Staining Buffers and Solutions . . . . . . . . . . . . . . . . . . . 64 Substrate Buffers and Solutions. . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Assay Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Immun-Blot® Assay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Total Protein Detection Procedures . . . . . . . . . . . . . . . . . . . . . . . . . 67
Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Trademarks and Legal Notices . . . . . . . . . . . . . . . . . . 73
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . 74

Protein Blotting

Appendices

Protein Blotting Guide 61

Appendices

Transfer Buffer Formulations

Transfer Buffer Formulations

The following buffers are recommended for use with all of Bio-Rad's electrophoretic transfer cells. Care should be taken when preparing these buffers because incorrect formulation can result in a current that exceeds the recommended conditions.

Note: Do not add acid or base to adjust the pH of the following buffers unless indicated. Addition of acid or base may change the ionic strength and conductivity of the buffer.

Only reagent-grade or electrophoresis-grade chemicals and deionized water should be used when preparing transfer buffers. If needed, methanol should be added last to prevent buffer precipitation problems. The formulas listed provide a total volume of 1 L.

Towbin buffer Towbin buffer with SDS

25 mM Tris, 192 mM glycine, 20% (v/v) methanol (pH 8.3) Dissolve 3.03 g Tris base and 14.4 g glycine in 500 ml deionized H2O; add 200 ml of methanol; adjust volume to 1 L with deionized H2O.
Note: the pH will range from pH 8.1 to 8.5 depending on the quality of the Tris, glycine, methanol, and deionized H2O.
25 mM Tris, 192 mM glycine, 20% methanol (v/v), 0.025­0.1% SDS (pH 8.3) Add 2.5 to 10 ml of 10% SDS to 1 L of buffer prepared above.

Bjerrum and Schafer-Nielsen buffer
Bjerrum and Schafer-Nielsen buffer with SDS

48 mM Tris, 39 mM glycine, 20% methanol (pH 9.2) Dissolve 5.82 g Tris base and 2.93 g glycine in 500 ml deionized H2O; add 200 ml methanol; adjust volume to 1 L with deionized H2O.
48 mM Tris, 39 mM glycine, 20% methanol, 1.3 mM SDS (pH 9.2) Add 0.0375 g SDS (or 3.75 ml of 10% SDS) to 1 L of buffer prepared above.

CAPS buffer

10 mM 3-(cyclohexylamino)-1-propanesulfonic acid, 10% methanol (pH 11.0)
Dissolve 2.21 g CAPS in 500 ml deionized H2O; add 100 ml methanol; adjust volume to 1 L with deionized H2O. Measure the pH; it may need to be adjusted with NaOH.

Dunn carbonate buffer 0.7% Acetic acid

10 mM NaHCO3, 3 mM NaCO3, 20% methanol (pH 9.9) Dissolve 0.84 g NaHCO3 and 0.318 g NaCO3 (anhydrous) in 500 ml deionized H2O; add 200 ml methanol; adjust volume to 1 L with deionized H2O.
Add 7 ml of glacial acetic acid to 1 L with deionized H2O.

62 Protein Blotting Guide

Detection Buffer Formulations

Appendices

Detection Buffer Formulations

General Detection Buffers

Tris-buffered saline (TBS)

20 mM Tris-HCl, 500 mM NaCl (pH 7.5)
Dissolve 4.84 g Tris base and 58.48 g NaCl in 1.5 L deionized H2O; adjust pH to 7.5 with HCl; adjust volume to 2 L with deionized H2O.

TTBS wash solution

20 mM Tris-HCl, 500 mM NaCl, 0.05% Tween 20 (pH 7.5) Add 0.5 ml Tween 20 to 1 L TBS.

Wash solution for chemiluminescence 20 mM Tris-HCl, 500 mM NaCl, 0.1% Tween 20 (pH 7.5) Add 1 ml Tween 20 to 1 L TBS.

Citrate-buffered saline (CBS)

20 mM citrate, 500 mM NaCl (pH 5.5) Included in Immun-Blot® protein G kits.

TCBS wash solution

20 mM citrate, 500 mM NaCl, 0.05% Tween 20 (pH 5.5) Add 0.5 ml Tween 20 to 1 L CBS.

Blocking solution

3% gelatin-TBS Add 3.0 g gelatin to 100 ml TBS. Heat to 50°C; stir to dissolve. or 1% BSA-TBS Add 1.0 g BSA to 100 ml TBS; stir to dissolve. or 5% nonfat milk-TBS Add 5.0 g nonfat dry milk to 100 ml TBS; stir to dissolve.

Note: Gelatin will clog the membrane and cut off the vacuum flow of the microfiltration units; an alternative blocking solution and antibody buffer must be used with the Bio-Dot® or Bio-Dot SF apparatus.

Blocking solution for chemiluminescence (general)

2% nonfat milk-TBS Add 0.2 g of nonfat dry milk to 10 ml TBS; stir to dissolve.

Note: This blocker is not recommended for avidin-biotin systems.

Antibody buffer

1% gelatin-TTBS Add 2.0 g gelatin to 200 ml TTBS. Heat to 50°C; stir to dissolve. or 1% BSA-TTBS Add 2.0 g BSA to 200 ml TTBS; stir to dissolve. or 5% nonfat milk-TTBS Add 10.0 g nonfat dry milk to 200 ml TTBS; stir to dissolve.

Note: Gelatin will clog the membrane and cut off the vacuum flow of the microfiltration units; an alternative blocking solution and antibody buffer must be used with the Bio-Dot or Bio-Dot SF apparatus.

Antibody buffer for chemiluminescence (Immun-StarTM AP only)

0.2% nonfat milk-TTBS Add 0.4 g nonfat milk to 200 ml TTBS; stir to dissolve.

Antibody buffer for protein G-HRP

1% gelatin-TCBS Add 1.0 g gelatin to 100 ml TCBS. Heat to 50°C; stir to dissolve.

Primary antibody solution

Dilute the primary antibody to the appropriate titer in 100 ml antibody buffer.

Secondary antibody solution

Dilute the secondary antibody conjugate at 1:3,000 by mixing 33 µl antibody conjugate in 100 ml antibody buffer.

Protein G-HRP conjugate solution

Mix 33 µl protein G conjugate solution in 100 ml 1% gelatin in TCBS.

Streptavidin-biotinylated AP complex

Add 33 µl of streptavidin to 100 ml TTBS. Add 33 µl of biotinylated AP to this solution. Allow the complex to incubate 1­3 hr at room temperature before use.

Protein Blotting Guide 63

Appendices

Detection Buffer Formulations

Total Protein Staining Buffers and Solutions

Colloidal Gold High-Tween TTBS for colloidal gold total protein stain

20 mM Tris-HCl, 500 mM NaCl, 0.3% Tween 20 (pH 7.5) Add 3 ml Tween 20 to 1 L of TBS.

Citrate buffer for colloidal gold staining

0.2 M citrate (pH 3.7)
Dissolve 27.0 g citric acid and 22.0 g sodium citrate in 1 L deionized H2O. If the pH of the buffer is above 4.0, remake the solution; do not adjust pH.

Enhancement solution for colloidal gold staining

Dissolve 0.85 g hydroquinone in 90 ml citrate buffer.
Dissolve 0.11 g silver lactate in 10 ml deionized H2O. Protect this solution from light. Mix the two solutions together.

Fixing solution for colloidal gold staining

Add 10 ml fixing solution concentrate to 90 ml deionized H2O.

Other Stains Borate-Tween solution (BT) for Biotin-BlotTM detection
Amido Black staining solution

0.05 M Na2B4O7·10 H2O, 0.2% Tween 20, pH 9.3 Dissolve 38.14 g Na2B4O7·10 H2O in 1.9 L deionized H2O. Add 4 ml Tween 20; adjust volume to 2 L with deionized H2O.
For nitrocellulose membrane blots: Dissolve 0.5% (w/v) Amido Black in 40% methanol or 25% isopropanol, 10% acetic acid.

For PVDF membrane blots: Dissolve 0.1% Amido Black in 40% methanol, 10% acetic acid.

Amido Black destain solution
Coomassie Blue R-250 staining solution Coomassie Blue R-250 destain solution Ponceau S staining solution

25% isopropyl alcohol, 10% acetic acid Mix 650 ml deionized H2O, 250 ml isopropyl alcohol, and 100 ml glacial acetic acid. or 40% methanol, 10% acetic acid (for PVDF membrane) Mix 500 ml deionized H2O, 400 ml methanol, and 100 ml glacial acetic acid.
0.1% Coomassie Blue R-250, 40% methanol, 10% acetic acid Dissolve 1 g Coomassie Blue R-250 in 500 ml deionized H2O, 400 ml methanol, 100 ml acetic acid.
40% methanol, 10% acetic acid Mix 400 ml methanol, 100 ml acetic acid, and 500 ml H2O.
0.2% Ponceau S and 3% TCA Dissolve 2 g Ponceau S with 30 g trichloracetic acid (TCA) and 30 g sulfosalicylic acid in 80 ml of water.

Ponceau S destain solution

1% acetic acid Mix 5 ml acetic acid up to 500 ml with water. Alternative: wash in PBS.

Substrate Buffers and Solutions

HRP Substrate Buffers 4-(chloro-1-naphthol) substrate solution (4CN)

Dissolve 60 mg 4CN in 20 ml methanol; protect this solution from light. Mix 600 µl 3% hydrogen peroxide into 100 ml TBS (see above). Mix the two solutions together. Use immediately. Alternatively, use HRP conjugate substrate solution in kit format.

HRP conjugate substrate solution (kit format)

Dissolve the contents of the premixed color development buffer in deionized H2O to a final volume of 1 L. Add 600 µl color reagent B to 100 ml color development buffer. Add 20 ml HRP color reagent A to this solution. Use immediately.

Diaminobenzidine (DAB)

Dissolve 50 mg DAB in 100 ml TBS (see above). Add 100 µl 3% hydrogen peroxide. Use immediately.

AP Substrate Buffers AP color development buffer
5-bromo-4-chloroindolyl phosphate/Nitroblue Tetrazolium (BCIP/NBT)

0.1 M Tris, 0.5 mM MgCl2 (pH 9.5) Dissolve 0.233 g MgCl2·H2O and 12.1 g Tris base in 800 ml deionized H2O. Adjust pH to 9.5 with HCl; adjust volume to 1 L with deionized H2O.
Prepare 1.0 ml 70% dimethylformamide (DMF) by mixing 0.7 ml DMF with 0.3 ml deionized H2O. Dissolve 30 mg NBT in the 70% DMF. Dissolve 15 mg BCIP in 1.0 ml DMF. Add both solutions to 100 ml AP color development buffer (see above). Use immediately. Alternatively, use AP conjugate substrate solution in kit format. Use AP conjugate substrate kit.

64 Protein Blotting Guide

Detection Buffer Formulations

Appendices

AP conjugate substrate solution (kit format) Immun-Star AP substrate solution (kit format)
Immun-Star HRP substrate solution (kit format)

Dissolve the contents of the premixed color development buffer in deionized H2O to a final volume of 1 L. Add 1.0 ml AP color development reagent A and 1.0 ml AP color development reagent B to 100 ml color development buffer. This solution can be stored overnight, but prompt use is recommended.
For nitrocellulose membrane blots: Add 500 µl of the enhancer reagent to 10 ml of Immun-Star chemiluminescent substrate. This solution can be stored at 4°C for up to one week.
For PVDF membrane blots: Immun-Star AP generates a very fast light signal on PVDF membrane; therefore, the use of an enhancer is not necessary. Use 10 ml chemiluminescent substrate per 200 cm2. The substrate is provided ready to use.
For nitrocellulose and PVDF membrane blots: A 1:1 mixture of luminol/enhancer to peroxide buffer is recommended. (12 ml of solution is sufficient for one 8.5 x 13.5 cm CriterionTM blot.)

Protein Blotting Guide 65

Appendices

Assay Procedures

Assay Procedures

The following is a generalized protocol for colorimetric immunological detection with the Immun-Blot HRP and AP kits. Notes on how this general procedure is modified for other detection systems are provided below. Consult the instruction manual for the particular assay you are using for complete instructions.

Immun-Blot Assay
Consult the Immun-Blot assay kit manual for complete instructions.

1. Wash

Following transfer or protein application, wash the membrane for 5­10 min in TBS.

2. Block

Incubate the membrane for 30 min to 1 hr in blocking solution.

3. Wash

Wash the membrane twice in TTBS, 5­10 min per wash.

4. Primary antibody

Incubate the membrane for 1­2 hr in the primary antibody solution.

5. Wash

Wash the membrane twice in TTBS, 5­10 min per wash.

6. Conjugate

Incubate the membrane for 30 min to 2 hr in the enzyme conjugate solution.

7. Wash

Wash the membrane twice in TTBS, 5­10 min per wash.

8. Final wash

Wash the membrane in TBS to remove the Tween 20 from the membrane surface prior to color development.

9. Signal development

Incubate the membrane for 5­30 min, depending on the detection method, in the color development/substrate solution.

10. Stop

Immerse the membrane for 10 min in deionized H2O to stop color development. Change the water at least once during this time to remove residual color development solution.

11. Read, dry, store

Take photographs while the membrane is wet to enhance the color. Dry membrane on filter paper and store between sheets of polyester. See procedural notes for chemiluminescent signal development.

Note for Protein G-HRP Detection Follow steps 1­4 above. For step 5 (wash), use TCBS instead of TTBS and then continue with steps 6­11.

Notes for Amplified Opti-4CN Detection Follow steps 1­8 above. Then:

· Incubate membrane in diluted BAR for 10 min

· Wash the membrane 2­4 times in 20% DMSO/PBST for 5 min each time

· Wash 1­2 times in PBST for 5 min. each time

· Incubate the membrane and diluted streptavidin-HRP for 30 min

· Wash the membrane twice in PBST for 5 min each time

Continue with steps 9­11.

Notes for Amplified AP Detection Follow steps 1­5 above. Then:

· Incubate the membrane for 1­2 hr in biotinylated secondary antibody solution

· While the blot is incubating in the biotinylated antibody solution, prepare the streptavidin-biotinylated AP complex. Allow the complex to form for 1 hr at room temperature

· Wash the membrane twice in TTBS, 5­10 min per wash

· Incubate the membrane for 1­2 hr in the streptavidin complex solution

Continue with steps 7­11.

66 Protein Blotting Guide

Assay Procedures

Appendices

Notes for Chemiluminescent Detection Follow steps 1­8 on previous page, except the wash steps 5 and 7 need to be more thorough. Wash the membrane 6 times for 10 min each with strong agitation and a large volume of buffer to reduce background. Then:
· Incubate the membrane for 3­5 min in the chemiluminescent substrate solution
· Drain excess liquid from the blot and seal the membrane in a bag
· Expose the blot to X-ray film (for example, Kodak XAR or BioMax) or instant photographic film, such as Polaroid Type 667 or 612. Typical exposure times are 30 sec to 5 min. Develop the film according to the manufacturer's instructions. Alternatively, an imager such as the Bio-Rad VersaDocTM or ChemiDocTM system can be used.

Total Protein Detection Procedures

Amido Black, Coomassie Blue R-250, or Ponceau S

1. Stain

Incubate for 1­2 min in the staining solution.

2. Destain

Destain in destain solution until the background clears.

3. Wash

Rinse in TBS or deionized H2O before drying.

Colloidal Gold Total Protein Stain Consult the Bio-Rad enhanced colloidal gold total protein detection kit manual for complete instructions.

1. Wash

Following transfer or protein application, wash the membrane 3 times for 20 min in high-Tween TBS.

2. Water rinse 3. Stain

Rinse for 2 min in deionized H2O to remove interfering buffer salts.
Incubate in colloidal gold stain. Incubation times will vary with the concentration of protein present on the membrane. Most bands will be visible in 1­2 hr. If increased sensitivity is required, continue the assay using the gold enhancement procedure.

Biotin-Blot Total Protein Detection Procedure Consult the Biotin-Blot total protein detection kit manual for complete assay instructions.

1. Wash

Following transfer or protein application, wash the membrane 3 times for 10 min in BT solution to remove interfering amine compounds.

2. Biotinylation

Place the membrane in a suitable container with 100 ml fresh BT solution. Add 200 µl NHS-biotin. Incubate for 15 min.

3. Wash

Wash twice in BT solution for 5 min.

4. Wash

Wash twice in TTBS for 5 min.

5. Conjugate

Incubate the membrane for 1­2 hr in the avidin-HRP solution.

6. Wash

Wash the membrane twice in TTBS, 5­10 min per wash.

7. Final wash

Wash the membrane in TBS to remove the Tween 20 from the membrane surface prior to color development.

8. Signal development Incubate the membrane for 5­30 min in an HRP color development/substrate solution.

9. Stop

Immerse the membrane for 10 min in deionized H2O to stop color development. Change the water at least once during this time to remove residual color development solution.

Protein Blotting Guide 67

Appendices

Glossary

Glossary
4-Chloro-1-naphthol (4CN)
5-Bromo-4-chloroindolyl phosphate (BCIP) Alkaline phosphatase (AP) Amido Black 10B Amplified AP kit Anionic dye Antibody Antigen Assay Avidin Background Bio-Dot® apparatus
Bio-Dot SF apparatus
Bio-IceTM unit Biotin Biotin-BlotTM kit Biotinylated standards
Bjerrum and SchaferNielsen buffer Blocking reagent Blot BLOTTO CDP-Star ChemiDocTM systems Chemiluminescence

a color development reagent used with horseradish peroxidase (HRP), which produces an insoluble purple reaction product at the site of an enzymeantibody complex a color development reagent used with alkaline phosphatase (AP), which in the presence of NBT produces an insoluble purple reaction product at the site of the enzyme-antibody complex
an enzyme used as a detection reagent, usually conjugated to a secondary antibody probe
an anionic dye used in the total protein detection of blots
a highly sensitive detection kit that utilizes a streptavidin-biotin system
a negatively charged compound used as a stain; used in blotting to stain proteins immobilized on membranes such as nitrocellulose or PVDF
an immunoglobulin; a protein produced in response to an antigen, which specifically binds the portion of the antigen that initiated its production
any molecule that specifically binds with an antibody
an analysis of the quantity or characteristics of a substance
a glycoprotein found in egg white that binds biotin with high specificity
nonspecific signal or noise that can interfere with the interpretation of valid signals
a microfiltration device, used in the immobilization of proteins in free solution onto a membrane; samples are loaded onto a 96-well template and filtered through the membrane by gravity or vacuum flow
a microfiltration device, used in the immobilization of proteins in free solution onto a membrane; sample are loaded onto a 48-slot template and filtered through the membrane by gravity or vacuum flow
a cooling unit used in the Mini Trans-Blot® cell
a small molecule that binds specifically to avidin or streptavidin
a total protein staining kit; utilizes biotinylation of the proteins on a membrane and the subsequent detection by avidin-HRP and 4CN
a mixture of proteins used as molecular weight markers, which have been treated to incorporate a limited number of biotin molecules. Because the relatively small biotin molecule does not appreciably alter the standard proteins' mobility in SDS-PAGE, accurate determination of antigen molecular weights directly on the membrane is possible
a commonly used transfer buffer (48 mM Tris, 39 mM glycine, 20% methanol, pH 9.2)
a protein used to saturate unoccupied binding sites on a blot to prevent nonspecific binding of antibody or protein probes to the membrane
immobilization of proteins or other molecules onto a membrane; or, the membrane that has the molecules adsorbed onto its surface
a formulation of nonfat milk used to block nonspecific binding of proteins to membranes
a reagent used in chemiluminescent blot detection with AP conjugated antibodies
CCD camera-based imaging systems for visualization and documentation of fluorescent, chemifluorescent, and colorimetric samples
the emission of light due to a chemical reaction; used in the specific detection of blotted molecules

68 Protein Blotting Guide

Glossary

Appendices

Colloidal gold
Color development reagent Colorimetric detection Conjugate Coomassie Blue CriterionTM blotter Diaminobenzidine (DAB)
Dot blot Dunn buffer Electrophoretic blotting Enhanced colloidal gold
Enzyme conjugate Fiber pad Filter paper Gelatin High-intensity transfer Horseradish peroxidase (HRP) Immunoassay Immunoblotting Immunodetection KaleidoscopeTM standards
Ligand Membrane
Membrane/filter paper sandwiches Microfiltration blotting Mini Trans-Blot cell

a stabilized sol of gold particles; used as a blot detection reagent when conjugated to antibodies or ligands. It produces a rose-red color on the membrane at the site of deposition
an enzyme substrate used in blotting to visualize the location of an enzymeantibody complex
detection of molecules of interest by formation of a colored product
an enzyme-antibody compound used in blotting
an anionic dye used in the total protein staining of gels and blots
a tank blotting apparatus, made specifically to transfer Criterion gels
a color development reagent used with HRP and other peroxidases, which produces an insoluble brown reaction product at the site of the peroxidaseantibody complex
the direct application of proteins in free solution to a membrane
a commonly used transfer buffer (10 mM NaHCO3, 3 mM Na2CO3, 20% methanol, pH 9.9)
the use of the driving force of an electric field to move proteins from gels to membranes
a procedure for amplification of detection sensitivity, where silver is deposited onto gold particles on a membrane after colloidal gold staining; the resulting black color increases the visibility of lightly stained positive signals
an enzyme covalently attached to another protein; in blotting, usually an antibody
a pad used in the Trans-Blot®, Mini Trans-Blot, and Criterion blotter cassettes that helps hold the gel and membrane sandwich in place
cotton fiber paper used in blotting applications and gel drying
a protein commonly used as a blocking reagent in western blotting procedures
a higher-power option available in the Trans-Blot cell and Criterion blotter, accomplished by moving the electrodes closer together, from 8 cm to 4 cm apart
an enzyme used in the specific detection of molecules on blots, usually conjugated to a secondary antibody probe
a test for a substance by its reactivity with an antibody
blot detection by antibody binding
detection of a molecule by its binding to an antibody
a mixture of molecular weight marker proteins from Bio-Rad that have covalently attached dyes of various colors, which make the bands visible during electrophoresis and transfer; when used to assess the transfer efficiency of proteins onto the membrane, the individually colored bands allow unambiguous identification of the standard proteins
a molecule that binds another in a complex
an immobilizing support medium used in blotting, generally in the form of a sheet that has high affinity for biological molecules; for example, nitrocellulose or PVDF
blotting membrane and filter paper precut for a specific gel size
the use of a microfiltration device, such as the Bio-Dot apparatus, to immobilize protein in free solution onto a membrane
a tank blotting apparatus, made specifically to transfer Ready Gel® and Mini-PROTEAN® gels; part of the modular Mini-PROTEAN line of products

Protein Blotting Guide 69

Appendices

Glossary

Multiscreen apparatus Native PAGE NHS-biotin Nitroblue Tetrazolium (NBT) Nitrocellulose Nonenzymatic probe
Nonfat dry milk Nonspecific binding PAGE Polyvinylidene difluoride (PVDF) membrane PowerPacTM power supplies Power supply Precision Plus ProteinTM standards Primary antibody Prestained standards
Probe Protein A Protein G
SDS-PAGE
Secondary antibody Semi-dry blotting
Signal-to-noise ratio StrepTactin Strep-tag sequence
Streptavidin

an instrument that allows the screening of two blots with up to 40 different antibody samples
a version of PAGE that retains native protein configuration, performed in absence of SDS and other denaturing agents
N-hydroxysuccinimide-biotin, a reagent that biotinylates proteins
a color development reagent used with AP, which with BCIP produces an insoluble purple reaction product at the site of the AP-antibody complex
a general-purpose blotting membrane
a molecule used in blot detection that does not involve an enzyme-catalyzed reaction; for example, a radioactive, chemiluminescent, or colloidal goldlabeled molecule
a material used in solution as a blocking reagent for western blots
the interaction between bound proteins and probes that is not a result of a specific reaction; results in spurious signals on the membrane
polyacrylamide gel electrophoresis, a common method of separating proteins
a membrane used in protein blotting, which has high chemical resistance, tensile strength, binding, and retentive capacity, making it ideal for use in protein sequencing
Bio-Rad's brand of power supplies
an instrument that provides the electric power to drive electrophoresis and electrophoretic blotting experiments
recombinant protein standards used in blotting and electrophoretic applications; available in all blue, unstained, dual color, and Kaleidoscope formats
an antibody that binds a molecule of interest
a mixture of molecular weight marker proteins that have covalently attached dye molecules, which render the bands visible during electrophoresis and transfer; used to assess the transfer efficiency of proteins onto the membrane
a molecule used to specifically identify another one
a protein derived from Staphylococcus aureus that binds a wide range of immunoglobulins from various species
a protein derived from Streptococcus that binds a wide range of immunoglobulins from various species, and has a wider range of binding capabilities than protein A
the separation of molecules by molecular weight in a polyacrylamide gel matrix in the presence of a denaturing detergent, sodium dodecyl sulfate (SDS)
an antibody that binds a primary antibody; used to facilitate detection
the use of a semi-dry blotting apparatus, which consists of two horizontally oriented plate electrodes. The gel and membrane sandwich is positioned between them with buffer-soaked filter paper on either side of the sandwich serving as buffer reservoirs
the relative difference in detection level between the specific and background signals
a genetically engineered form of streptavidin, used with the Precision Plus Protein unstained standards for detection
an amino acid sequence that can be used to tag a protein, enabling its detection by StrepTactin binding; this sequence is present in Precision Plus Protein unstained standards
a protein that binds biotin with high affinity; generally regarded as superior to avidin because it is not glycosylated

70 Protein Blotting Guide

Glossary

Appendices

Substrate Super cooling coil Supported nitrocellulose Tank blotting
Total protein stain Towbin buffer Trans-Blot® cell Trans-Blot® Plus cell Trans-Blot SD cell Transfer Tween 20 VersaDocTM system Western blotting

a substance that is reacted upon by an enzyme; for example, a color development reagent
an optional accessory of the Trans-Blot cell, which can be attached to a refrigerated water recirculator to cool the buffer during high-intensity transfers
a high-tensile-strength blotting membrane; nitrocellulose that has been cast on an inert high-strength support
the use of a tank blotting apparatus, which consists of a tank of buffer with vertically oriented platinum wire or plate electrodes; the gel and membrane are held in place between the electrodes by a porous cassette
a reagent that binds nonspecifically to proteins; used to detect the entire protein pattern on a blot or gel
a common protein blotting transfer buffer (25 mM Tris, pH 8.5, 192 mM glycine, 20% methanol)
a tank-blotting apparatus for large and mini gels
a tank blotting apparatus for very large gels
a semi-dry blotting apparatus for large and mini gels
the immobilization of proteins or other molecules onto a membrane by electrophoretic or passive means
a nonionic detergent; used in blot detection procedures as a blocking reagent or added to wash buffers to minimize nonspecific binding and background
a CCD camera-based imaging system
the immobilization of proteins onto a membrane, and the subsequent detection by protein-specific binding and detection reagents

Protein Blotting Guide 71

Appendices

References

References

Akerstrom B et al., Protein G: a powerful tool for binding and detection of monoclonal and polyclonal antibodies, J Immunol 135, 2589­2592 (1985)
Bayer EA and Wilchek M, The use of the avidin-biotin complex as a tool in molecular biology, Methods Biochem Anal 26, 1­45 (1980)
Beisiegel U, Protein blotting, Electrophoresis 7, 1­18 (1986)
Bers G and Garfin D, Protein and nucleic acid blotting and immunobiochemical detection, Biotechniques 3, 276­288 (1985)
Bjerrum OJ and Schafer-Nielsen C, Buffer systems and transfer parameters for semidry electroblotting with a horizontal apparatus, pp 315­327 in Dunn MJ (ed) Electrophoresis '86: proceedings of the fifth meeting of the International Electrophoresis Society, VCH, Weinheim, Germany (1986)
Blake MS et al., A rapid, sensitive method for detection of alkaline phosphatase-conjugated anti-antibody on Western blots, Anal Biochem 136, 175­179 (1984)
Boyle MDP and Reis KJ, Bacterial Fc receptors, Biotechnology 5, 697­703 (1987)
Burnette WN, "Western blotting": electrophoretic transfer of proteins from sodium dodecyl sulfate-polyacrylamide gels to unmodified nitrocellulose and radiographic detection with antibody and radioiodinated protein A, Anal Biochem 112, 195­203 (1981)
Carr DW and Scott JD, Blotting and band-shifting: techniques for studying protein-protein interactions, Trends Biochem Sci 17, 246­249 (1992)
Chaiet L and Wolf FJ, The properties of streptavidin, a biotin-binding protein produced by Streptomyces, Arch Biochem Biophys 106, 1­5 (1964)
Crisp SJ and Dunn MJ, Detection of proteins on protein blots using chemiluminescent systems, Methods Mol Biol 32, 233­237 (1994)
Della-Penna D et al., Biotinylated proteins as molecular weight standards on Western blots, Anal Biochem 152, 329­332 (1986)
Dunn MJ, Detection of proteins on blots using the avidinbiotin system, Methods Mol Biol 32, 227­232 (1994)
Dunn MJ, Detection of total proteins on western blots of 2-D polyacrylamide gels, Methods Mol Biol 112, 319­329 (1999)
Egger D and Bienz K, Protein (western) blotting, Mol Biotechnol 1, 289­305 (1994)
Garfin DE and Bers G, Basic aspects of protein blotting, pp 5­41 in Baldo BA et al. (eds) Protein Blotting. Methodology, Research and Diagnostic Applications, Karger, Basel (1989)
Gershoni JM, Protein blotting: developments and perspectives, Trends Biochem Sci 10, 103­106 (1985)

Gershoni JM, Protein blotting: a tool for the analytical biochemist, pp 141­175 in Chrambach A et al. (eds) Advances in Electrophoresis, Vol 1, VCH, Weinheim, Germany (1987)
Gershoni JM, Protein blotting: a manual, Methods Biochem Anal 33, 1­58 (1988)
Gershoni JM and Palade GE, Protein blotting: principles and applications, Anal Biochem 131, 1­15 (1983)
Gershoni JM et al., Protein blotting in uniform or gradient electric fields, Anal Biochem 144, 32­40 (1985)
Goding JW, Use of staphylococcal protein A as an immunological reagent, J Immunol Methods 20, 241­253 (1978)
Gooderham K, Transfer techniques in protein blotting, Methods Mol Biol 1, 165­178 (1984)
Guesdon J-L et al., The use of avidin-biotin interaction in immunoenzymatic techniques, J Histochem Cytochem 27, 1131­1139 (1979)
Harper DR et al., Protein blotting: ten years on, J Virol Methods 30, 25­39 (1990)
Hawkes R et al., A dot-immunobinding assay for monoclonal and other antibodies, Anal Biochem 119, 142­147 (1982)
Hsu SM et al., Use of avidin-biotin-peroxidase complex (ABC) in immuno-peroxidase techniques: a comparison between ABC and unlabeled antibody (PAP) procedures, J Histochem Cytochem 29, 577­580 (1981)
Kurien BT and Scofield RH, Protein blotting: a review, J Immunol Methods 274, 1­15 (2003)
Kyhse-Andersen J, Electroblotting of multiple gels: a simple apparatus without buffer tank for rapid transfer of proteins from polyacrylamide to nitrocellulose, J Biochem Biophys Methods 10, 203­209 (1984)
Langone JJ, Use of labeled protein A in quantitative immunochemical analysis of antigens and antibodies, J Immunol Methods 51, 3­22 (1982)
Moeremans M et al., The use of colloidal metal particles in protein blotting, Electrophoresis 8, 403­409 (1987)
Reinhart MP and Malamud D, Protein transfer from isoelectric focusing gels: the native blot, Anal Biochem 123, 229­235 (1982)
Rohringer R and Holden DW, Protein blotting: detection of proteins with colloidal gold, and of glycoproteins and lectins with biotin-conjugated and enzyme probes, Anal Biochem 144, 118­127 (1985)
Tovey ER and Baldo BA, Comparison of semi-dry and conventional tank-buffer electrotransfer of proteins from polyacrylamide gels to nitrocellulose membranes, Electrophoresis 8, 384­387 (1987)
Tovey ER and Baldo BA, Characterisation of allergens by protein blotting, Electrophoresis 8, 452­463 (1987)

72 Protein Blotting Guide

Trademarks and Legal Notices

Appendices

Towbin H et al., Electrophoretic transfer of proteins from polyacrylamide gels to nitrocellulose sheets: procedure and some applications, Proc Natl Acad Sci USA 76, 4350­4354 (1979)
Tsang VC et al., Calibration of prestained protein molecular weight standards for use in the "Western" or enzyme-linked immunoelectrotransfer blot techniques, Anal Biochem 143, 304­307 (1984)
Tsang VC et al., Enzyme-linked immunoelectrotransfer blot (EITB), pp 389­414 in Ngo TT and Lenhoff HM (eds) Enzyme-Mediated Immunoassay, Plenum Press, New York (1985)

Turner BM, The use of alkaline-phosphatase-conjugated second antibody for the visualization of electrophoretically separated proteins recognized by monoclonal antibodies, J Immunol Methods 63, 1­6 (1983)
Wisdom GB, Protein blotting, Methods Mol Biol 32, 207­213 (1994)

Trademarks and Legal Notices

The following trademarks used in this guide are the property of Bio-Rad Laboratories:

Bio-Dot® Bio-IceTM Bio-Rad® Bio-SafeTM Biotin-BlotTM ChemiDocTM ChemiDocTM XRS CriterionTM

De-ExposeTM GS-800TM Immun-Blot® Immun-StarTM KaleidoscopeTM Mini-PROTEAN® Mini Trans-Blot® Molecular Imager FXTM Pro Plus

Opti-4CNTM PowerPacTM PowerPacTM Basic PowerPacTM Universal Precision Plus ProteinTM Precision ProteinTM PROTEAN® PROTEAN® Plus

Quantity One® Ready Gel® Sequi-BlotTM Trans-Blot® Trans-Blot® Plus VersaDocTM

Acrobat is a trademark of Adobe Systems Incorporated. BioMax and Kodak are trademarks of Eastman Kodak Co. CDP-Star is a trademark of Tropix, Inc. Coomassie is a trademark of BASF Aktiengesellschaft. Nonidet is a trademark of Shell International Petroleum Co. Polaroid is a trademark of Polaroid Corporation. StrepTactin and Strep-tag are trademarks of Institut für Bioanalytik GmbH. Strep-tag technology for western blot detection is covered by U.S. patent 5,506,121 and by UK patent 2,272,698. StrepTactin is covered by German patent application P 19641876.3. Bio-Rad Laboratories, Inc. is licensed by Institut für Bioanalytik GmbH to sell this product for research use only. SYPRO and Texas Red are trademarks of Molecular Probes, Inc. Bio-Rad Laboratories, Inc. is licensed by Molecular Probes, Inc. to sell SYPRO products for research use only, under US patent 5,616,502. Tween is a trademark of ICI Americas, Inc.

Protein Blotting Guide 73

Appendices

Ordering Information

Ordering Information

Electrophoretic Transfer Cells

Catalog #

Description

Trans-Blot Cells and Systems

170-3939

Trans-Blot Cell With Plate Electrodes and Super Cooling Coil,

includes 2 gel holder cassettes, buffer tank, lid with power

cables, 4 fiber pads, 1 pack precut blot absorbent filter paper

170-3853

Trans-Blot Cell With Plate Electrodes, Super Cooling Coil, and

PowerPac HC Power Supply

170-3946

Trans-Blot Cell With Plate Electrodes,* includes 2 gel holder

cassettes, buffer tank, lid with power cables, 4 fiber pads,

1 pack precut blot absorbent filter paper

170-3850

Trans-Blot Cell With Plate Electrodes and PowerPac HC

Power Supply

170-3910

Trans-Blot Cell With Wire Electrodes, includes 2 gel holder

cassettes, buffer tank, lid with power cables, 4 fiber pads,

1 pack precut blot absorbent filter paper

170-3825

Trans-Blot Cell With Wire Electrodes and PowerPac HC

Power Supply

Trans-Blot Cell Accessories

170-3914

Fiber Pads, 15.5 x 20.5 cm, 6

170-3956

Trans-Blot Thick Blot Paper, 15 x 20 cm, 25 sheets

170-3960

Extra Thick Blot Paper, 15 x 20 cm, 30 sheets

170-3943

Trans-Blot Platinum Anode Plate Electrode

170-3944

Trans-Blot Stainless Steel Cathode Plate Electrode

170-3945

Trans-Blot Plate Electrode Pair, platinum anode and

stainless steel cathode

170-3920

Trans-Blot Standard Wire Electrode Card, cathode

170-3921

Trans-Blot Standard Wire Electrode Card, anode

170-3912

Super Cooling Coil,* required for all high-intensity transfers

170-3913

Gel Holder Cassette, includes 2 fiber pads

170-3922

Trans-Blot Cell Buffer Tank

170-3923

Trans-Blot Cell Lid With Cables

Trans-Blot Plus Cell and Systems

170-3990

Trans-Blot Plus Cell With Plate Electrodes and Super

Cooling Coil, includes 3 gel holder cassettes, buffer tank,

lid with power cables, 6 fiber pads, 1 pack blot absorbent

filter paper (26.5 x 28 cm, 30 sheets), roller, stirbar

170-3991

Trans-Blot Plus Cell With Plate Electrodes, Super Cooling

Coil, and PowerPac HC Power Supply

170-3992

Trans-Blot Plus Cell With Plate Electrodes, Super Cooling

Coil, and PowerPac Universal Power Supply

Trans-Blot Plus Cell Accessories

170-3994

Trans-Blot Plus Gel/Cassette Assembly Tray

170-3995

Fiber Pads, 27 x 28.5 cm, 2

170-3996

Trans-Blot Plus Filter Paper, 26.5 x 28 cm, 60 sheets

170-3997

Stirbar

170-3998

Trans-Blot Plus Roller, 6" wide

170-3999

Trans-Blot Plus Gel Holder Cassette With Clamps

170-4990

Trans-Blot Plus Super Cooling Coil

170-4991

Trans-Blot Plus Platinum Anode Plate Electrode

170-4992

Trans-Blot Plus Stainless-Steel Cathode Plate Electrode

170-4995

Trans-Blot Plus Cell Buffer Tank

170-4996

Trans-Blot Plus Cell Lid With Cables

170-4997

Gel Holder Cassette Clamps, set of 3

Mini Trans-Blot Cell and Systems

170-3930

Mini Trans-Blot Electrophoretic Transfer Cell, includes 2 gel

holder cassettes, 4 fiber pads, modular electrode assembly,

Bio-Ice cooling unit, lower buffer tank, lid with cables, 1

pack precut blot absorbent filter paper (thick), instructions

170-3935

Mini Trans-Blot Module, without lower buffer tank and lid

170-3989 170-3836 165-3323
165-3324

Mini Trans-Blot Cell and PowerPac Basic Power Supply Mini Trans-Blot Cell and PowerPac HC Power Supply Mini-PROTEAN 3 Cell, Mini Trans-Blot Module, and PowerPac Basic Power Supply Mini-PROTEAN 3 Module, Mini Trans-Blot Module, and PowerPac Basic Power Supply

Mini Trans-Blot Cell Accessories

170-3931

Mini Gel Holder Cassette

170-3932

Mini Trans-Blot Filter Paper (Thick), 7.5 x 10 cm, 50 sheets

170-3933

Fiber Pads, 8 x 11 cm, 4

170-3934

Bio-Ice Cooling Unit

800-2105

Central Core Assembly, for Mini Trans-Blot cell

Criterion Blotters and Systems

170-4070

Criterion Blotter With Plate Electrodes, includes cell

assembled with plate electrodes, lid with cables, 2 Criterion

gel holder cassettes, 4 fiber pads, 1 pack precut blot

absorbent filter paper, gel/blot assembly tray, roller, sealed

ice block, instructions

170-4071

Criterion Blotter With Wire Electrodes, includes cell

assembled with wire electrodes, lid with cables, 2 Criterion

gel holder cassettes, 4 fiber pads, 1 pack precut blot

absorbent filter paper, gel/blot assembly tray, roller, sealed

ice block, instructions

165-6024

Criterion Cell/Plate Blot System, includes Criterion cell and

Criterion blotter with plate electrodes

165-6025

Criterion Cell/Wire Blot System, includes Criterion cell and

Criterion blotter with wire electrodes

170-3872

Criterion Blotter With Plate Electrodes and PowerPac HC

Power Supply

170-3874

Criterion Blotter With Wire Electrodes and PowerPac HC

Power Supply

Criterion Blotter Accessories

170-4076

Optional Criterion Blotter Cooling Coil

170-4080

Criterion Gel Holder Cassette

170-4081

Criterion Blotter Platinum Anode Plate Electrode

170-4082

Criterion Blotter Stainless-Steel Cathode Plate Electrode

170-4083

Criterion Blotter Wire Electrode Card, anode

170-4084

Criterion Blotter Wire Electrode Card, cathode

170-4085

Criterion Blotter Filter Paper, 9.5 x 15.2 cm, 50 sheets

170-4086

Criterion Blotter Fiber Pads, 9.5 x 15.2 cm, 4

170-4087

Sealed Ice Block, 2

170-4089

Criterion Gel/Blot Assembly Tray

165-1279

Roller

170-4077

Criterion Blotter Buffer Tank

170-4079

Criterion Blotter Lid With Cables

Trans-Blot SD Semi-Dry Cell and Systems

170-3940

Trans-Blot SD Semi-Dry Electrophoretic Transfer Cell,

includes Trans-Blot SD transfer cell, Trans-Blot SD agarose

gel support frame, extra thick blot paper, instructions

170-3848

Trans-Blot SD Cell and PowerPac HC Power Supply

170-3849

Trans-Blot SD Cell and PowerPac Universal Power Supply

Trans-Blot SD Cell Accessories

170-3947

Cathode Plate, stainless-steel upper electrode

170-3942

Anode Plate, platinum-coated lower electrode

170-3966

Extra Thick Blot Paper, for Mini-PROTEAN 3 or Ready Gel®

precast gels, 7 x 8.4 cm, 60 sheets

170-3967

Extra Thick Blot Paper, for Criterion gels, 8 x 13.5 cm,

60 sheets

170-3968

Extra Thick Blot Paper, for PROTEAN® II xi gels, 14 x 16 cm,

30 sheets

170-3969

Extra Thick Blot Paper, for PROTEAN II XL gels, 18 x 18.5 cm,

30 sheets

* Trans-Blot cells require a super cooling coil for high-intensity transfers; the super cooling coil is recommended for all applications using plate electrodes.

74 Protein Blotting Guide

Ordering Information

Appendices

Microfiltration Apparatus

Catalog #

Description

Bio-Dot Apparatus and Systems

170-3938

Bio-Dot Microfiltration System, includes Bio-Dot and

Bio-Dot SF templates, vacuum manifold base, gasket

support plate, gasket

170-6545

Bio-Dot Apparatus, includes Bio-Dot sample template,

vacuum manifold base, gasket support plate, gasket

170-6547

Bio-Dot Module, without vacuum manifold base, for

conversion of Bio-Dot SF to Bio-Dot apparatus

170-6542

Bio-Dot SF Apparatus, includes Bio-Dot SF sample

template, vacuum manifold base, gasket support plate,

gasket, filter paper

170-6543

Bio-Dot SF Module, without vacuum manifold base,

for conversion of Bio-Dot to Bio-Dot SF apparatus

Bio-Dot System Accessories

170-6546

Bio-Dot Gaskets, 3

170-6544

Bio-Dot SF Gaskets, 2

162-0161

Bio-Dot/Bio-Dot SF Filter Paper, 11.3 x 7.7 cm, 60 sheets

Power Supplies

Catalog #

Description

164-5052 164-5070

PowerPac HC Power Supply PowerPac Universal Power Supply

Nitrocellulose Membranes

Catalog #

Description

Nitrocellulose Membrane (0.45 µm)

162-0115

Nitrocellulose Membrane, 30 cm x 3.5 m, 1 roll

162-0113

Nitrocellulose Membranes, 20 x 20 cm, 5 sheets

162-0116

Nitrocellulose Membranes, 15 x 15 cm, 10 sheets

162-0114

Nitrocellulose Membranes, 15 x 9.2 cm, 10 sheets

162-0148

Nitrocellulose Membranes, 11.5 x 16 cm, 10 sheets

162-0117

Nitrocellulose Membranes, 9 x 12 cm, 10 sheets

162-0145

Nitrocellulose Membranes, 7 x 8.4 cm, 10 sheets

162-0251

Nitrocellulose Membranes, 26.5 x 28 cm, 10 sheets

162-0234

Nitrocellulose/Filter Paper Sandwiches, 8.5 x 13.5 cm,

20 pack

162-0235

Nitrocellulose/Filter Paper Sandwiches, 8.5 x 13.5 cm,

50 pack

162-0214

Nitrocellulose/Filter Paper Sandwiches, 7 x 8.5 cm,

20 pack

162-0215

Nitrocellulose/Filter Paper Sandwiches, 7 x 8.5 cm,

50 pack

Nitrocellulose Membrane (0.2 µm)

162-0112

Nitrocellulose Membrane, 30 cm x 3.5 m, 1 roll

162-0150

Nitrocellulose Membranes, 20 x 20 cm, 5 sheets

162-0147

Nitrocellulose Membranes, 13.5 x 16.5 cm, 10 sheets

162-0146

Nitrocellulose Membranes, 7 x 8.4 cm, 10 sheets

162-0252

Nitrocellulose Membranes, 26.5 x 28 cm, 10 sheets

162-0232

Nitrocellulose/Filter Paper Sandwiches, 8.5 x 13.5 cm,

20 pack

162-0233

Nitrocellulose/Filter Paper Sandwiches, 8.5 x 13.5 cm,

50 pack

162-0212

Nitrocellulose/Filter Paper Sandwiches, 7 x 8.5 cm, 20 pack

162-0213

Nitrocellulose/Filter Paper Sandwiches, 7 x 8.5 cm, 50 pack

Supported Nitrocellulose Membrane (0.45 µm)

162-0094

Supported Nitrocellulose Membrane, 30 cm x 3 m, 1 roll

162-0093

Supported Nitrocellulose Membranes, 20 x 20 cm, 10 sheets

162-0092

Supported Nitrocellulose Membranes, 15 x 15 cm, 10 sheets

162-0091

Supported Nitrocellulose Membranes, 10 x 15 cm, 10 sheets

162-0090

Supported Nitrocellulose Membranes, 7 x 8.4 cm, 10 sheets

162-0254

Supported Nitrocellulose Membranes, 26.5 x 28 cm,

10 sheets

Supported Nitrocellulose Membrane (0.2 µm)

162-0097

Supported Nitrocellulose Membrane, 30 cm x 3 m, 1 roll

162-0096

Supported Nitrocellulose Membranes, 15 x 15 cm, 10 sheets

162-0095

Supported Nitrocellulose Membranes, 7 x 8.4 cm, 10 sheets

162-0253

Supported Nitrocellulose Membranes, 26.5 x 28 cm,

10 sheets

PVDF Membranes

Catalog #

Description

Sequi-Blot PVDF Membrane

162-0184

Sequi-Blot PVDF Membrane, 24 cm x 3.3 m, 1 roll

162-0182

Sequi-Blot PVDF Membranes, 20 x 20 cm, 10 sheets

162-0185

Sequi-Blot PVDF Membranes, 20 x 20 cm, 3 sheets

162-0181

Sequi-Blot PVDF Membranes, 15 x 15 cm, 10 sheets

162-0180

Sequi-Blot PVDF Membranes, 10 x 15 cm, 10 sheets

162-0186

Sequi-Blot PVDF Membranes, 7 x 8.4 cm, 10 sheets

162-0236

Sequi-Blot PVDF/Filter Paper Sandwiches, 8.5 x 13.5 cm,

20 pack

162-0237

Sequi-Blot PVDF/Filter Paper Sandwiches, 8.5 x 13.5 cm,

50 pack

162-0216

Sequi-Blot PVDF/Filter Paper Sandwiches, 7 x 8.5 cm,

20 pack

162-0217

Sequi-Blot PVDF/Filter Paper Sandwiches, 7 x 8.5 cm,

50 pack

Immun-Blot PVDF Membrane

162-0177

Immun-Blot PVDF Membrane, 26 cm x 3.3 m, 1 roll

162-0176

Immun-Blot PVDF Membranes, 20 x 20 cm, 10 sheets

162-0175

Immun-Blot PVDF Membranes, 10 x 15 cm, 10 sheets

162-0174

Immun-Blot PVDF Membranes, 7 x 8.4 cm, 10 sheets

162-0238

Immun-Blot PVDF/Filter Paper Sandwiches, 8.5 x 13.5 cm,

20 pack

162-0239

Immun-Blot PVDF/Filter Paper Sandwiches, 8.5 x 13.5 cm,

50 pack

162-0218

Immun-Blot PVDF/Filter Paper Sandwiches, 7 x 8.5 cm,

20 pack

162-0219

Immun-Blot PVDF/Filter Paper Sandwiches, 7 x 8.5 cm,

50 pack

Blotting Membrane/Filter Paper Sandwiches

Catalog #

Description

Ready Gel Membrane/Filter Paper Sandwiches

162-0212

0.2 µm Nitrocellulose/Filter Paper Sandwiches, 7 x 8.5 cm,

20 pack

162-0213

0.2 µm Nitrocellulose/Filter Paper Sandwiches, 7 x 8.5 cm,

50 pack

162-0214

0.45 µm Nitrocellulose/Filter Paper Sandwiches, 7 x 8.5 cm,

20 pack

162-0215

0.45 µm Nitrocellulose/Filter Paper Sandwiches, 7 x 8.5 cm,

50 pack

162-0218

Immun-Blot PVDF/Filter Paper Sandwiches, 7 x 8.5 cm,

20 pack

162-0219

Immun-Blot PVDF/Filter Paper Sandwiches, 7 x 8.5 cm,

50 pack

162-0216

Sequi-Blot PVDF/Filter Paper Sandwiches, 7 x 8.5 cm,

20 pack

162-0217

Sequi-Blot PVDF/Filter Paper Sandwiches, 7 x 8.5 cm,

50 pack

Protein Blotting Guide 75

Appendices

Ordering Information

Criterion Membrane/Filter Paper Sandwiches

162-0232

0.2 µm Nitrocellulose/Filter Paper Sandwiches, 8.5 x 13.5 cm,

20 pack

162-0233

0.2 µm Nitrocellulose/Filter Paper Sandwiches, 8.5 x 13.5 cm,

50 pack

162-0234

0.45 µm Nitrocellulose/Filter Paper Sandwiches, 8.5 x 13.5 cm,

20 pack

162-0235

0.45 µm Nitrocellulose/Filter Paper Sandwiches, 8.5 x 13.5 cm,

50 pack

162-0238

Immun-Blot PVDF/Filter Paper Sandwiches, 8.5 x 13.5 cm,

20 pack

162-0239

Immun-Blot PVDF/Filter Paper Sandwiches, 8.5 x 13.5 cm,

50 pack

162-0236

Sequi-Blot PVDF/Filter Paper Sandwiches, 8.5 x 13.5 cm,

20 pack

162-0237

Sequi-Blot PVDF/Filter Paper Sandwiches, 8.5 x 13.5 cm,

50 pack

Blot Absorbent Filter Paper

Catalog #

Description

170-3932 170-3966
170-4085 170-3967
170-3959 170-3968
170-3956 170-3969
170-3960 170-3996 162-0161

Mini Trans-Blot Filter Paper (Thick), 7.5 x 10 cm, 50 sheets Extra Thick Blot Paper, for Mini-PROTEAN 3 or Ready Gel precast gels, 7 x 8.4 cm, 60 sheets Criterion Blotter Filter Paper, 9.5 x 15.2 cm, 50 sheets Extra Thick Blot Paper, for Criterion gels, 8 x 13.5 cm, 60 sheets Extra Thick Blot Paper, 15 x 15 cm, 30 sheets Extra Thick Blot Paper, for PROTEAN II xi gels, 14 x 16 cm, 30 sheets Trans-Blot Thick Filter Paper, 15 x 20 cm, 25 sheets Extra Thick Blot Paper, for PROTEAN II XL gels, 18 x 18.5 cm, 30 sheets Extra Thick Blot Paper, 15 x 20 cm, 30 sheets Trans-Blot Plus Filter Paper, 26.5 x 28 cm, 60 sheets Bio-Dot/Bio-Dot SF Filter Paper, 11.3 x 77 cm, 60 sheets

Buffer Reagents

Catalog #

Description

Electrophoresis Buffer Reagents

161-0710

2-Mercaptoethanol, 25 ml

161-0750

Boric Acid, 500 g

161-0751

Boric Acid,1 kg

161-0707

Citric Acid, 100 g

161-0610

Dithiothreitol (DTT), 1 g

161-0611

DTT, 5 g

163-2101

Tributylphosphine (TBP), 200 mM, 0.6 ml

163-2109

Iodoacetamide, 30 g

161-0728

EDTA, 100 g

161-0729

EDTA, 500 g

161-0717

Glycine, 250 g

161-0718

Glycine, 1 kg

161-0724

Glycine, 2 kg

161-0720

Sucrose, 1 kg

161-0712

Tricine, 100 g

161-0713

Tricine, 500 g

161-0716

Tris, 500 g

161-0719

Tris, 1 kg

161-0730

Urea, 250 g

161-0731

Urea, 1 kg

Premixed Buffers

Catalog #

Description

Electrophoresis Buffers

161-0732

10x Tris/Glycine/SDS, 1 L

161-0772

10x Tris/Glycine/SDS, 5 L cube

161-0734

10x Tris/Glycine, 1 L

161-0771

10x Tris/Glycine, 5 L

76 Protein Blotting Guide

Blot Transfer and Processing Buffers

161-0778

10x Tris/CAPS, 1 L

161-0774

20x SSC, 1 L

161-0775

20x SSC, 5 L cube

161-0780

10x Phosphate Buffered Saline, 1 L

170-6435

10x Tris Buffered Saline, 1 L

Detergents/Blocking Reagents

170-6537

Gelatin, EIA grade, 200 g

170-6404

Blotting-Grade Blocker, nonfat dry milk, 300 g

170-6531

Tween 20, EIA grade, 100 ml

161-0781

10% Tween 20, 1 L

161-0418

SDS Solution, 20% (w/v), 1 L

161-0783

1x Phosphate Buffered Saline With 1% Casein, 1 L

161-0782

1x Tris Buffered Saline With 1% Casein, 1 L

Blotting Standards

Catalog #

Description

Unstained Standards

161-0304

SDS-PAGE Standards, low range, 200 µl

161-0303

SDS-PAGE Standards, high range, 200 µl

161-0317

SDS-PAGE Standards, broad range, 200 µl

161-0326

SDS-PAGE Standards, polypeptide, 200 µl

161-0363

Precision Plus Protein Unstained Standards, 1,000 µl

Blotting Standards and Conjugates

161-0306

Biotinylated SDS-PAGE Standards, low range, 250 µl

161-0307

Biotinylated SDS-PAGE Standards Kit, low range, avidin-HRP

161-0308

Biotinylated SDS-PAGE Standards Kit, low range, avidin-AP

161-0311

Biotinylated SDS-PAGE Standards, high range, 250 µl

161-0312

Biotinylated SDS-PAGE Standards Kit, high range,

avidin-HRP

161-0313

Biotinylated SDS-PAGE Standards Kit, high range,

avidin-AP

161-0319

Biotinylated SDS-PAGE Standards, broad range, 250 µl

161-0321

Biotinylated SDS-PAGE Standards Kit, broad range,

avidin-HRP

161-0322

Biotinylated SDS-PAGE Standards Kit, broad range,

avidin-AP

161-0380

Precision ProteinTM StrepTactin-HRP Conjugate, 300 µl

161-0382

Precision Protein StrepTactin-AP Conjugate, 300 µl

Prestained Standards

161-0305

Prestained SDS-PAGE Standards, low range, 500 µl

161-0309

Prestained SDS-PAGE Standards, high range, 500 µl

161-0318

Prestained SDS-PAGE Standards, broad range, 500 µl

161-0324

Kaleidoscope Prestained Standards, broad range, 500 µl

161-0325

Kaleidoscope Polypeptide Standards, 500 µl

161-0373

Precision Plus Protein All Blue Standards, 500 µl

161-0374

Precision Plus Protein Dual Color Standards, 500 µl

161-0375

Precision Plus Protein Kaleidoscope Standards, 500 µl

Detection Reagents

Catalog #

Description

Total Protein Stains and Components

161-0402

Amido Black 10B, 25 g

161-0400

Coomassie Brilliant Blue R-250, 10 g

170-6517

Enhanced Colloidal Gold Total Protein Detection Kit,

includes colloidal gold total protein stain, Tris, Tween 20,

gold enhancement kit, instructions

170-6512

Biotin-Blot Total Protein Detection Kit, includes NHS-biotin,

avidin-HRP, Tween 20, Tris, HRP color development

reagent (4CN), instructions

170-3127

SYPRO Ruby Protein Blot Stain, 200 ml

Ordering Information

Appendices

Immun-Blot AP Colorimetric Assay Kits

170-6460

Immun-Blot AP Goat Anti-Rabbit IgG (H + L) Assay Kit

170-6461

Immun-Blot AP Goat Anti-Mouse IgG (H + L) Assay Kit

170-6462

Immun-Blot AP Goat Anti-Human IgG (H + L) Assay Kit

170-6412

Immun-Blot Amplified AP Assay Kit

Immun-Blot amplified AP kit includes 0.5 ml biotinylated antibody, 0.5 ml

streptavidin, 0.5 ml biotinylated AP, premixed Tris-buffered saline, nonfat milk,

Tween 20, and AP conjugate substrate kit. Immun-Blot AP kits include 0.5 ml

antibody conjugate, premixed Tris-buffered saline, Tween 20, gelatin, and

substrate kit.

Blotting-Grade AP Conjugates

170-6533

Avidin-AP, 1 ml

170-3554

Streptavidin-AP, 0.5 ml

170-6518

Goat Anti-Rabbit IgG-AP, 1 ml

170-6520

Goat Anti-Mouse IgG-AP, 1 ml

170-6521

Goat Anti-Human IgG-AP, 1 ml

Immun-Blot HRP Colorimetric Assay Kits

170-6463

Immun-Blot HRP Goat Anti-Rabbit IgG (H + L) Assay Kit

170-6464

Immun-Blot HRP Goat Anti-Mouse IgG (H + L) Assay Kit

170-6465

Immun-Blot HRP Goat Anti-Human IgG (H + L) Assay Kit

170-6466

Immun-Blot Protein A Assay Kit

170-6467

Immun-Blot Protein G Assay Kit

170-8235

Opti-4CN Substrate Kit

170-8237

Opti-4CN Goat Anti-Mouse Detection Kit

170-8236

Opti-4CN Goat Anti-Rabbit Detection Kit

170-8238

Amplified Opti-4CN Substrate Kit

170-8240

Amplified Opti-4CN Goat Anti-Mouse Detection Kit

170-8239

Amplified Opti-4CN Goat Anti-Rabbit Detection Kit

Immun-Blot HRP kits include 0.5 ml antibody conjugate, premixed Tris-

buffered saline, Tween 20, gelatin, and substrate kit.

Blotting-Grade HRP Conjugates

170-6515

Goat Anti-Rabbit IgG-HRP, 2 ml

170-6516

Goat Anti-Mouse IgG-HRP, 2 ml

172-1050

Goat Anti-Human IgG-HRP, 2 ml

170-6522

Protein A-HRP, 1 ml

170-6425

Protein G-HRP, 1 ml

170-6528

Avidin-HRP, 2 ml

Blotting Substrate Reagents

170-6431

HRP Conjugate Substrate Kit, contains premixed 4CN and

hydrogen peroxide solutions, color development buffer;

prepares 1 L of color development solution

170-6432

AP Conjugate Substrate Kit, contains premixed BCIP and

NBT solutions, color development buffer; prepares 1 L of

color development solution

170-6534

HRP Color Development Reagent, 4CN, 5 g

170-6535

HRP Color Development Reagent, DAB, 5 g

170-6539

AP Color Development Reagent, BCIP, 300 mg

170-6532

AP Color Development Reagent, NBT, 600 mg

170-6401

Biotinylated Goat Anti-Rabbit IgG (H + L), 1 ml

170-6403

Blotting-Grade Biotinylated AP, 1 ml

170-6408

Blotting-Grade Streptavidin, 1 mg

170-6529

NHS-Biotin, 4 ml

Immun-Star AP Chemiluminescent Assay Kits

170-5010

Immun-Star AP Goat Anti-Mouse Detection Kit, includes

substrate, enhancer, antibody

170-5011

Immun-Star AP Goat Anti-Rabbit Detection Kit, includes

substrate, enhancer, antibody

170-5012

Immun-Star AP Substrate Pack, includes substrate, enhancer

170-5013

Immun-Star AP Goat Anti-Mouse Intro Kit, includes

complete reagents for 8 mini blots

170-5014

Immun-Star AP Goat Anti-Rabbit Intro Kit, includes

complete reagents for 8 mini blots

170-5018

Immun-Star AP Substrate

170-5015

Blotting Reagents Pack, includes TBS, Tween 20, blocker

All items except intro kits cover 2,500 cm2 membrane. For complete blotting

kits, add the blotting reagents pack to the detection kits. The intro kits

provide a low-cost trial of the assay.

Immun-Star HRP Chemiluminescent Assay Kits

170-5040

Immun-Star HRP Substrate, 500 ml

170-5041

Immun-Star HRP Substrate, 100 ml

170-5042

Immun-Star Goat Anti-Rabbit-HRP Detection Reagents,

include substrate, antibody, 500 ml

170-5043

Immun-Star Goat Anti-Mouse-HRP Detection Reagents,

include substrate, antibody, 500 ml

170-5045

Immun-Star Goat Anti-Rabbit-HRP Detection Kit, includes

complete reagents, 500 ml

170-5044

Immun-Star Goat Anti-Mouse-HRP Detection Kit, includes

complete reagents, 500 ml

170-5046

Immun-Star Goat Anti-Rabbit-HRP Conjugate, 2 ml

170-5047

Immun-Star Goat Anti-Mouse-HRP Conjugate, 2 ml

500 ml kits are sufficent for 4,000 cm2 of membrane; 100 ml kits are

sufficent for 800 cm2 of membrane

Detection Accessories

Catalog #

Description

Mini Incubation Trays

170-3902

Mini Incubation Trays, 20

170-3903

Mini Incubation Trays, 100

Mini-PROTEAN II Multiscreen Apparatus

170-4017

Mini-PROTEAN II Multiscreen Apparatus, includes 2

sample templates, 2 gaskets, base plate

170-4018

Multiscreen Gaskets, 2

Background Remover

170-5020

De-Expose Background Remover, 250 ml, 10x

Documentation Systems

Catalog #

Description

170-7980 170-7981 170-8070 170-8071 170-8140 170-8141 170-8050 170-8151 170-7850 170-7851

GS-800 Calibrated Densitometer, PC GS-800 Calibrated Densitometer, Mac ChemiDoc XRS System, PC ChemiDoc XRS System, Mac VersaDoc 4000 Imaging System, PC VersaDoc 4000 Imaging System, Mac VersaDoc 5000 Imaging System, PC VersaDoc 5000 Imaging System, Mac Molecular Imager FX Pro Plus MultiImager System, PC Molecular Imager FX Pro Plus MultiImager System, Mac

Protein Blotting Guide 77

Bio-Rad Laboratories, Inc.

Life Science Group

Web site www.bio-rad.com USA (800) 4BIORAD Australia 02 9914 2800 Austria (01)-877 89 01 Belgium 09-385 55 11 Brazil 55 21 2527 3454 Canada (905) 712-2771 China (86-21) 63052255 Czech Republic + 420 2 41 43 05 32 Denmark 44 52 10 00 Finland 09 804 22 00 France 01 47 95 69 65 Germany 089 318 84-0 Hong Kong 852-2789-3300 Hungary 36 1 455 8800 India (91-124)-6398112/113/114, 6450092/93 Israel 03 951 4127 Italy 39 02 216091 Japan 03-5811-6270 Korea 82-2-3473-4460 Latin America 305-894-5950 Mexico 55-52-00-05-20 The Netherlands 0318-540666 New Zealand 64 9 415 2280 Norway 23 38 41 30 Poland + 48 22 331 99 99 Portugal 351-21-472-7700 Russia 7 095 721 1404 Singapore 65-6415 3188 South Africa 00 27 11 4428508 Spain 34 91 590 5200 Sweden 08 555 12700 Switzerland 061 717-9555 Taiwan (8862) 2578-7189/2578-7241 United Kingdom 020 8328 2000

P/N 411-0188 Bulletin 2895 US/EG Rev A

02-661 0504 Sig 1103


Acrobat Distiller 5.0.5 for Macintosh