Installation Guide for PARADOX models including: PGM82-EI01, PGM82 8-PGM Expansion Module, PGM82, 8-PGM Expansion Module, Expansion Module, Module

PGM82-EI01

ekavouris

PGM82 - tssupplies.co.nz

paradox.com PGM82-EI01 11/2017 Programming EVO 1. Enter section [0901] - [0932]. 2. Enter the eight-digit serial number and three-digit output number. 3. Enter the 3-digit Event Group, Feature Group, Start # and End #


File Info : application/pdf, 2 Pages, 389.46KB

PDF preview unavailable. Download the PDF instead.

media.nl?id=2830888&c=3471189&h=UGKOBAKRO7CYdPNyGSW79cIib4qPgiNwNwC1TROxrggaI9kF
Upgrading Firmware

PGM82
8-PGM Expansion Module
Installation Manual Lock

The PGM82's firmware can be upgraded in Infield via BabyWare using a 307USB Direct Connect Interface.

Manual Activation and Display
LED Indicators

Data Power

LED PGM1 to PGM8

OFF Deactivated

ON Activated

DATA

No clock / no data

Panel connected

Introduction
The 8-PGM Expansion Module PGM82 includes eight programmable relay outputs and is compatible with all Paradox control panels. Outputs can be independently activated using the Insite GOLD mobile application, manually by pressing the PGM button on the front cover or they can be programmed to follow system events. Manual activation does not require a bus connection.
Compatibility
· EVO192, EVOHD v6.80 and higher · MG5000, MG5050, SP5500, SP6000, SP7000 v6.80 and higher · PGM4 v5.01 and higher · BabyWare v5.1 and higher · Infield v5.1 and higher · Insite GOLD iOs v1.5; Android v1.4
Connections
Connect the four terminals labeled RED BLK GRN YEL of the module to the corresponding terminals on the control panel's four-wire combus as shown below.
Manual Switches

POWER

No Power

10.5 to 16V Flash - Below 10.3V

* If control panel has an AC Loss, all LEDs are turned off.

Insite Gold
Adding PGMs to Camera and Security Screens
1. Press from the Security or Video screen.
2. Select the PGM you wish to add. 3. Press Save.
The selected PGMs will appear on Security and Video screens.

To Enable/Disable PGMs

Output Relays Manual activation is timed and will shutdown after 15 minutes (default). paradox.com

1. Open Insite GOLD app. 2. Select the PGM tab on the bottom. 3. Press the toggle button to enable/dis-
able the PGM. 4. When activating a PGM a countdown
clock will be shown.
In the EDIT PEN icon, you can label each PGM and change the OFF time; default is set to 15 minutes.
Labels will be saved in the EVO panels. On MG/SP, it is saved only on the mobile device (need to be labeled on each mobile device).

PGM82-EI01 11/2017

Programming EVO

1. Enter section [0901] - [0932]. 2. Enter the eight-digit serial number and three-digit output number. 3. Enter the 3-digit Event Group, Feature Group, Start # and End #
for PGM activation. 4. Enter the 3-digit Event Group, Feature Group, Start #, and End#
for PGM deactivation. 5. Define the PGM Delay Value (001 to 255 x 1 sec./min.). Default
set to 15 minutes. 6. Set your PGM options, refer to table.

OPTION DESCRIPTION

PGM # OFF ON

1

PGM deactivation after (OFF = deactivation event; ON = PGM timer)





2

PGM base time (OFF = seconds; ON = minutes)





Flexible PGM deactivation option

3 (OFF = PGM timer only; ON = PGM





timer and/or deactivation event)

4

PGM initial state (OFF = normally open;  ON = normally closed)



5

PGM Time base (Off = follow option 2,  ON = hour)



6 to 8 Future use

-

-

Programming MGSP
1. Enter section [236] - [251]. 2. Enter the 3-digit Event Group, Sub Group, and Partition for PGM
activation. Section default values are set to 00/00/00 with the exception of Section [244] - activation default values are set to 08/99/01; Section [246] - activation default values are set to 09/99/01. 3. Enter the 3-digit Event Group, Sub Group, and Partition for PGM deactivation. Section default values are set to 00/00/00 with the exception of Section [245] - deactivation default values are set to 08/99/01; Section [247] - deactivation default values are set to 09/99/01. 4. Enter section [269] - [276] to define the PGM Delay Value (001 to 255 x 1 sec./min.). 5. Enter section [349] - [356] to define your PGM Labels. 6. Set your PGM options, refer to table below.

OPTION DESCRIPTION
1 PGM base time (OFF = sec., ON = min.) 2 PGM state (OFF = N.O., ON = N.C.)

PGM #

OFF ON









3

PGM supervision (not applicable to SP4000





4

PGM activation mode (OFF = steady, ON = pulse)





5

PGM pulse once every 30 seconds, if armed





6 PGM pulse on any alarm





7

PGM pulse on any alarm (OFF - partition  1, ON = partition 2)



Flexible PGM deactivation option

8

(OFF* = PGM delay only, two activation  events, ON = PGM delay or deactivation



event, whichever comes first)

* If a PGM delay is programmed (OFF option), the deactivation event can be used as a second activation event.

Warranty For complete warranty information on this product, please refer to the Limited Warranty Statement is found on the website: www.paradox.com/terms or contact your local distributor. Specifications may change without prior notice.
Patents US, Canadian and international patents may apply. Paradox is a trademark or registered trademark of Paradox Security Systems (Bahamas) Ltd.
paradox.com

Technical Specifications

Input Voltage

11 to 16 Vdc

Current Consumption

315 mA max (all PGMs activated)

Number of outputs

8 Form `C' relays

Output

24V, 4A any load

Operating Temperature -20 C to +50 C (-4 F to 122 F)

Humidity

95% maximum

Box Dimensions (H x W x D)

16.5 cm x 10.2 cm x 2.5 cm (6.5 in x 4 in x 1 in)

PGM82-EI01 11/2017

