22-1942-1C-EN

Product Data - Trane

Product Data March 2020 N 4TTR7048B Note: “Graphics in this document are for representation only. Actual model may differ in appearance.” Split System Cooling R17 - 4 Ton

Go Now

Trane Model Number Nomenclature Construction › Url: https://www.trane.com/content/dam/Trane/Commercial/global/products-systems/equipment/unitary/split-systems/split-systems-1-1-2-to-5-tons/22-1942-1C-EN

4TTR7 (22-1942-1*)

Split System Air Conditioners and Heat Pumps

PDF preview unavailable. Download the PDF instead.

22-1942-1C-EN
Product Data
Split System Cooling
XR17 - 4 Ton
4TTR7048B

March 2020

Note: "Graphics in this document are for representation only. Actual model may differ in appearance."
22-1942-1C-EN

Features and Benefits

· CLIMATUFFTM 2-stage scroll
compressor
· Efficiency up to 18.0 SEER · All Aluminum SPINE FINTM coil · DURATUFFTM weather proof and
rust proof base
· COMFORT "R"TM mode
approved for better comfort indoors
· QUICK-SESSTM cabinet,
service access and refrigerant connections with full coil protection
· WEATHERGUARDTM fasteners · Glossy corrosion resistant finish
tarpaulin gray cabinet with anthracite gray top

· Internal compressor high/low
pressure & temperature protection
· Liquid line filter/drier · Low sound with advanced PSC fan
motor
· Service valve cover · R-410A refrigerant · From 70 to 100% capacity
modulation
· 100% run test in the factory · Low ambient cooling to 55° as
shipped
· Extended warranties available

© 2020 Trane

2

22-1942-1C-EN

Contents

Features and Benefits

2

General Data

4

Product Specifications

4

A-weighted Sound Power Level [dB(A)]

4

Accessory Description and Usage

4

AHRI Standard Capacity Rating Conditions

4

Model Nomenclature

5

Electrical Data

6

Model Nomenclature

8

Mechanical Specifications

9

22-1942-1C-EN

3

General Data

Product Specifications

Model No. 
Electrical Data V/Ph/Hz  Min Cir Ampacity Max Fuse Size (Amps)
Compressor No. Compress. ­ No. Stages

4TTR7048B1000A
208/230/1/60 28 45
CLIMATUFF® - SCROLL 1-2

RL AMPS - LR AMPS

20.4 - 122

Outdoor Fan FL Amps Fan HP Fan Dia (inches)
Coil Refrigerant R-410A Line Size - (in.) O.D. Gas 

2.8 1/3 27.6
Spine FinTM 13/3-LB/OZ
7/8

Line Size - (in.) O.D. Liquid 
Dimensions H x W x D (Crated) Weight - Shipping Weight - Net
Start Components Sound Enclosure Compressor Sump Heat
Optional Accessories:  Rubber Isolator Kit

3/8 51.0 x 35.1 x 38.7
296 259 NO NO NO
BAYISLT101

Accessory Description and Usage
Rubber Isolators -- 5 rubber donuts to isolate condensing unit from mounting frame or pad. Use on any application where sound transmission needs to be minimized. Extreme Conditions Mounting Kit -- Bracket kits to securely mount condensing unit to a frame or pad without removing any panels. Use in areas with high winds, or on commercial rooftops, etc. Low Ambient Cooling -- For low ambient cooling below 55° see Application Guide APP-APG013-EN.
AHRI Standard Capacity Rating Conditions
AHRI STANDARD 210/240 RATING CONDITIONS -- (A) Cooling 80°F DB, 67°F WB air entering indoor coil,
95°F DB air entering outdoor coil. (B) High Temperature Heating 47°F DB, 43°F WB air entering
outdoor coil, 70°F DB air entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering
outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. AHRI STANDARD 270 RATING CONDITIONS -- (Noise rating numbers are determined with the unit in cooling operation.) S tandard Noise Rating number is at 95°F outdoor air.

Snow Leg - Base & Cap 4" High BAYLEGS002

Snow Leg - 4" Extension Hard Start Kit Scroll Crankcase Heater Kit Extreme Condition Mounting Kit Vertical Discharge Air Kit Base 4 Auto Charge Solenoid Kit Refrigerant Lineset 

BAYLEGS003 BAYKSKT266 BAYCCHT301 BAYECMT004 BAYVDTA004 BAYCAKT001

 Certified in accordance with the Air-Source Unitary Heat Pump Equipment certification program which is based on AHRI Standard 210/240.
 Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses.  Standard line lengths - 60'. Standard lift - 25' Suction and Liquid line.
For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0. (denotes latest
revision)
 For accessory description and usage, see page 4.  25, 30, 35 and 50 foot linesets available. For a complete listing of lineset options available
from equipment or supply stores, refer to the Trane Residential and Light Commercial Product
Handbook.

Sound Power Level

Model

A-Weighted Sound Power Level [dB(A)]

63 Hz

125 Hz

Full Octave Sound Power [dB] 250 Hz 500 Hz 1000 Hz 2000 Hz

4TTR7048B

73

70

67

68

66

63

56

Note: Rated in accordance with AHRI Standard 270-2008 4

4000 Hz 8000 Hz

53

49

22-1942-1C-EN

Dimensions
4TTR7 Outline Drawing
Note: All dimensions are in MM (Inches).

MODELS BASE

A

B

C

DE

4TTR7048B

4 1147 (45 1/8) 946 (37-1/4) 870 (34-1/4) 7/8 3/8

F 152 (6)

G

H

J

98 (3-7/8) 219 (8-5/8) 86 (3-3/8)

K 813 (32)

22-1942-1C-EN

From Dwg. D152635 5

Electrical Data
Schematic Diagram

6

22-1942-1C-EN

Electrical Data
Wiring Diagram

22-1942-1C-EN

7

Model Nomenclature

Outdoor Units

4T TR7 0 36A1 000AA

Refrigerant Type 4 = R-410A

TRANE

Product Type W = Split Heat Pump T = Split Cooling

Product Family Z = Leadership ­ Two Stage X = Leadership R = Replacement/Retail M or B = Basic A = Light Commercial

Family SEER 3 = 13 6 = 16 4 = 14 8 = 18 5 = 15 9 = 19

0 = 20

Split System Connections 1-6 Tons 0 = Brazed

Nominal Capacity in 000s of BTUs

Major Design Modifications

Power Supply 1 = 200-230/1/60 or 208-230/1/60 3 = 200-230/3/60 4 = 460/3/60

Secondary Function

Minor Design Modifications

Unit Parts Identifier

Gas Furnaces

T U D 1 B 0 8 0 A 9 H 3 1 A A

Furnace Configuration TU = Upflow/Horizontal TD = Downflow/Horizontal

Type E = 80% Induced Draft Standard D = 80% Induced Draft Premium C = 90% Condensing Standard X = 90% Condensing Premium H = 95% Condensing Premium

Number of Heating Stages 1 = Single Stage 2 = Two Stage M = Modulating

Cabinet Width A = 14.5" Cabinet Width B = 17.5" Cabinet Width C = 21.0" Cabinet Width D = 24.5" Cabinet Width

Heating Input in 1000's (BTUH) 080 = 80,000 BTUH

Major Design Change

Voltage 9 = 115 Volts / 60 Hertz / Natural Gas A = 115 Volts / 50 Hertz / Natural Gas C = 115 Volts / Natural Gas with Communicating System Control F = 115 Volts / Natural Gas with Integrated Electronic Filter D = 115 Volts / Natural Gas with Communicating System Control and
Integrated Electronic Filter

Air Capacity for Cooling Standard PSC Variable Speed 24 = 2 Tons V3 = 3 Tons 36 = 3 Tons V4 = 4 Tons 42 = 3.5 Tons V5 = 5 Tons 45 = 4 Tons 48 = 4 Tons 54 = 5 Tons 60 = 5 Tons 72 = 6 Tons
Draft Inducer Speeds 1 = Single Speed 2 = Two Speed V = Variable Speed

High Efficiency H3 = 3 Tons H4 = 4 Tons H5 = 5 Tons

Minor Design Change

Service Digit - Not Orderable

8

Air Handler

G A M 5 A 0 B 3 6 M 3 1 S A A

Brand T = Better G = Good
Product Type A = Air Handler
Convertability M = Multi-poise 4-way F = Upflow Front Return, 3-way T = 3-way
Product Tier 2 = Good, Entry Level Feature Set 4 = Better, Retail Replacement Mid Effy. 5 = Better, Entry Level High Effy., Multi-Speed 7 = Best, Retail Replacement High Effy.,
Variable-Speed 8 = Best, Retail Ultimate High Effy.,
Variable-Speed
Major Design Change
No Descriptor 0 = Air Handler / Coil
Size (Footprint) A = 17.5 x 21.5 B = 21.0 x 21.5 C = 23.5 x 21.5
Cooling Size: Air Handler or Coil 0-9 = AH Coil - 1000 BTU's (18, 24, 30, 36, 42, 48, 60)
Airflow Type & Capability S = Low Effy PSC, 1-5 - nom. Tonnage (cfm/ton) M = Mid Effy Multi-Speed, 1-5 - nom. Tonnage (cfm/ton) H = High Effy Multi-Speed, 1-5 - nom. Tonnage (cfm/ton) V = High Effy Variable, 1-5 - nom. Tonnage (cfm/ton)
Power Supply 1 = 208-230/1/60
System Control Type S = Standard - 24 VAC C = CLII 13.8 VDC
Minor Design Change
Unit Parts Identifier

Heat Pump/ Cooling Coils

4 T X C B 0 36 A C 3 H C A A

Refrigerant Type 4 = R-410A
Series T = Premium (Heat Pump or Convertible Coil) C = Standard (Cooling Only)
Coil Design X = Direct Expansion Evaporator Coil
Coil Feature C = Cased A Coil A = Uncased A Coil F = Cased Horizontal Flat Coil
Coil Width (Cased/Uncased) A = 14.5" /13.3" B = 17.5" / 16.3" C = 21.0" / 19.8" D = 24.5" / 23.3" H = 10.5"
Refrigerant Line Coupling 0 = Brazed
Nominal Capacity in 1000's (BTUH)
Major Design Change
Efficiency C = Standard S = Hi Efficiency (derived from 10 SEER products)
Refrigerant Control 3 = TXV - Non-Bleed
Coil Circuitry H = Heat Pump C = Cooling
Airflow Configuration A = Upflow Only U = Upflow / Downflow H = Horizontal Only C = Convertible - Upflow, Downflow, Left or Right Airflow
Minor Design Change
Service Digit - Not Orderable

22-1942-1C-EN

Mechanical Specifications

General The outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit, ten (10) feet of tested connecting line, and the smallest rated indoor evaporative coil match. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit shall be certified to UL 1995. Exterior is designed for outdoor application.
Casing Unit casing is constructed of heavy gauge, G60 galvanized steel and painted with a weather-resistant powder paint on all louvers and panels. Corrosion and weatherproof CMBP-G30 DuraTuffTM base.
Refrigerant Controls Refrigeration system controls include condenser fan, compressor contactor and high pressure switch. High and low pressure controls are inherent to the compressor. A factory installed liquid line drier is standard.

Compressor The Climatuff® 2-stage compressor features internal over temperature and pressure protection and hermetic motor. Other features include: centrifugal oil pump and modular plugs for electrical connections.
Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels.
Low Ambient Cooling As manufactured, this unit has a cooling capability to 55°F. For low ambient cooling below 55° see Application Guide.

22-1942-1C-EN

9

Trane - by Trane Technologies (NYSE: TT), a global climate innovator - creates comfortable, energy efficient indoor environments for commercial and residential applications. For more information, please visit trane.com or tranetechnologies.com.

The AHRI Certified mark indicates Trane U.S. Inc. participation in the AHRI Certification program. For verification of individual certified products, go to ahridirectory.org.

Trane has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices.

22-1942-1C-EN 24 Mar 2020 Supersedes 22-1942-1B-EN (May 2019)

© 2020 Trane


Adobe InDesign 15.0 (Windows) Adobe PDF Library 15.0; modified using iText 2.1.7 by 1T3XT