ConnectX-3.book

sherind

ConnectX -3 Ethernet Single and Dual SFP Ports Mezzanine ...

This manual is intended for the installer and user of these cards. The manual assumes basic familiarity with Ethernet networks and architecture specifications. Related ation

ConnectX -3 Ethernet Single and Dual SFP Ports ... - Mellanox

.mellanox.com => Products Software =>. Ethernet Drivers => => Firmware Tools. Make sure to download the package corresponding to your com- puter's operating system. a. Enter: mst ...

ConnectX-3.book | About this Manual 8

This manual is intended for the installer and user of these cards. ... ConnectX -3 Ethernet Single and Dual SFP Ports Mezzanine Card User Manual for Open Compute Project.

PDF preview unavailable. Download the PDF instead.

ConnectX-3 Ethernet Single and Dual SFP Port Mezzanine Card User Manual for OCP
ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open
Compute Project
P/N: MCX341A-XCAN, MCX341A-XCBN, MCX342A-XCAN
Rev 1.9
www.mellanox.com

Rev 1.9
NOTE: THIS HARDWARE, SOFTWARE OR TEST SUITE PRODUCT ("PRODUCT(S)") AND ITS RELATED DOCUMENTATION ARE PROVIDED BY MELLANOX TECHNOLOGIES "AS-IS" WITH ALL FAULTS OF ANY KIND AND SOLELY FOR THE PURPOSE OF AIDING THE CUSTOMER IN TESTING APPLICATIONS THAT USE THE PRODUCTS IN DESIGNATED SOLUTIONS. THE CUSTOMER'S MANUFACTURING TEST ENVIRONMENT HAS NOT MET THE STANDARDS SET BY MELLANOX TECHNOLOGIES TO FULLY QUALIFY THE PRODUCTO(S) AND/OR THE SYSTEM USING IT. THEREFORE, MELLANOX TECHNOLOGIES CANNOT AND DOES NOT GUARANTEE OR WARRANT THAT THE PRODUCTS WILL OPERATE WITH THE HIGHEST QUALITY. ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT ARE DISCLAIMED. IN NO EVENT SHALL MELLANOX BE LIABLE TO CUSTOMER OR ANY THIRD PARTIES FOR ANY DIRECT, INDIRECT, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES OF ANY KIND (INCLUDING, BUT NOT LIMITED TO, PAYMENT FOR PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY FROM THE USE OF THE PRODUCT(S) AND RELATED DOCUMENTATION EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

Mellanox Technologies 350 Oakmead Parkway Suite 100 Sunnyvale, CA 94085 U.S.A. www.mellanox.com Tel: (408) 970-3400 Fax: (408) 970-3403

© Copyright 2013. Mellanox Technologies. All Rights Reserved.
Mellanox®, Mellanox logo, BridgeX®, ConnectX®, CORE-Direct®, InfiniBridge®, InfiniHost®, InfiniScale®, PhyX®, SwitchX®, UFM®, Virtual Protocol Interconnect® and Voltaire® are registered trademarks of Mellanox Technologies, Ltd.
Connect-IBTM, FabricITTM, MLNX-OSTM, MetroXTM, MetroDXTM, ScalableHPCTM, Unbreakable-LinkTM are trademarks of Mellanox Technologies, Ltd.
All other trademarks are property of their respective owners.

2

Mellanox Technologies

Document Number: 3691

ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project

Rev 1.9

Table of Contents
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
List of Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
List of Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
About this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Chapter 1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.1 Supported Network Protocol Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 1.2 Adapter Cards Covered in this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 1.3 Finding the MAC and Serial Number on the Mezzanine Card . . . . . . . . . . . . . . . 11 1.4 Safety Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Chapter 2 Mezzanine Card Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.1 I/O Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.1.1 Ethernet SFP+ Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2.1.2 PCI Express Mezzanine Connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2.1.3 I2C-compatible Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2.1.4 Unified Extensible Firmware Interface (UEFI) . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.2 Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2.3 Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.3.1 System Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 2.3.2 SPI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 2.3.3 EEPROM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Chapter 3 Ethernet Mezzanine Card Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
3.1 Hardware Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 3.2 Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 3.3 Identify the Card in Your System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
3.3.1 On Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 3.3.2 On Linux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
3.4 Cables and Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Chapter 4 Driver Software and Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
4.1 Driver Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
4.1.1 Linux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 4.1.2 Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
4.2 VMware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 4.3 FlexBoot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 4.4 RDMA over Converged Ethernet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
4.4.1 Hardware and Software Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
4.5 Updating Mezzanine Card Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Appendix A Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Appendix B Interface Connectors Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Appendix C Avertissements de sécurité d'installation (Warnings in French) . . . . . . . . . . . . . 34 Appendix D Advertencias de seguridad para la instalación (Warnings in Spanish) . . . . . . . 37

Mellanox Technologies 3

Rev 1.9
List of Figures
Figure 1: MCX341A-XCAN Board Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Figure 2: MCX341A-XCBN Board Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Figure 3: MCX342A-XCAN Board Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Figure 4: I2C-compatible Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Figure 5: PCI Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Figure 6: Device Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Figure 7: Support Download Assistant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Figure 8: Mechanical Drawing of the Dual-port MCX342A-XCAN Mezzanine Card . . . . . . . . . . 29 Figure 9: Mechanical Drawing of the Single-port MCX341A-XC[AB]N Mezzanine Card . . . . . . 30 Figure 10: Compatible Connector Plug and Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Figure 11: PCIe Connector Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Figure 12: SFP+ Cage Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

4

Mellanox Technologies

ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project

List of Tables

Table 1: Table 2: Table 3: Table 4: Table 5: Table 6: Table 7: Table 8: Table 9:

Revision History Table 6 Documents List 8 Single and Dual-port 10 Gigabit Ethernet Adapter Card 10 Jumper Configuration 15 MCX342A-XCAN VPD Layout 15 MCX341A-XC[AB]N VPD Layout 17 MCX342A-XCAN Specifications Table 27 MCX341A-XC[AB]N Specifications Table 28 I2C-compatible Connector Pinout 31

Rev 1.9

Mellanox Technologies 5

Rev 1.9

Revision History

This document was printed on February 19, 2013.

Table 1 - Revision History Table

Date

Rev

Comments/Changes

February 2013 December 2012 October 2012 September 2012 September 2012
July 2012
May 2012

1.9

· Added Section 4.2, "VMware," on page 24

· Updated Figure 5, "PCI Device," on page 20 and Figure 6,

"Device Manager," on page 23

· Updated all Web links

1.8

· Updated labels in Figure 1, "MCX341A-XCAN Board

Label," on page 11, Figure 2, "MCX341A-XCBN Board

Label," on page 11 and Figure 3, "MCX342A-XCAN

Board Label," on page 12

· Added "Cable Support" to Appendix A.1, "MCX342A-

XCAN Specifications," on page 27 and Appendix A.2,

"MCX341A-XC[AB]N Specifications," on page 28

1.7

· Updated mechanical drawings removing unused components.

See Appendix A.3, "Board Mechanical Drawing and

Dimensions," on page 29

1.6

· Fixed dimensions in Figure 8, "Mechanical Drawing of the

Dual-port MCX342A-XCAN Mezzanine Card," on

page 29 and Figure 9, "Mechanical Drawing of the Single-

port MCX341A-XC[AB]N Mezzanine Card," on page 30

1.5

· Added operational and non-operational temperature and humid-

ity level to Table 7, "MCX342A-XCAN Specifications

Table," on page 27 and Table 8, "MCX341A-XC[AB]N

Specifications Table," on page 28

1.4

· Added OPN MCX341A-XCBN to the following locations:

· Chapter 1,"Overview" on page 10

· Table 3, "Single and Dual-port 10 Gigabit Ethernet

Adapter Card," on page 10

· Figure 2, "MCX341A-XCBN Board Label," on page 11

· Table 6, "MCX341A-XC[AB]N VPD Layout," on

page 17

· Appendix A.2, "MCX341A-XC[AB]N Specifications,"

on page 28

· Figure 9, "Mechanical Drawing of the Single-port

MCX341A-XC[AB]N Mezzanine Card," on page 30

· Added new board label of the MCX341A-XCAN Mezz card. See

Figure 1, "MCX341A-XCAN Board Label," on page 11.

· Added Section 2.1.4, "Unified Extensible Firmware Inter-

face (UEFI)," on page 14

1.3

· Updated Figure 1, "MCX341A-XCAN Board Label," on

page 11 to show board revision at A3

6

Mellanox Technologies

ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project

Rev 1.9

Date April 2012
March 2012 November 2011

Rev

Comments/Changes

1.2

· Added note on SFP+ transceiver modules to Section 3.4,

"Cables and Modules," on page 21

· Updated Figure 8, "Mechanical Drawing of the Dual-port

MCX342A-XCAN Mezzanine Card," on page 29

· Added Figure 9, "Mechanical Drawing of the Single-port

MCX341A-XC[AB]N Mezzanine Card," on page 30

1.1

· Added Section 1.2, "Adapter Cards Covered in this Man-

ual," on page 10

· Added new board labels to Section 1.3, "Finding the MAC

and Serial Number on the Mezzanine Card," on page 11

· Updated Section 4.1.1, "Linux," on page 22

1.0

First Release

Mellanox Technologies 7

Rev 1.9

About this Manual
This User Manual describes Mellanox Technologies ConnectX®-3 10 Gigabit Ethernet Single and Dual SFP+ Port PCI Express x4 Mezzanine cards. It provides details as to the interfaces of the board, specifications, required software and firmware for operating the board, and relevant documentation.

Intended Audience
This manual is intended for the installer and user of these cards. The manual assumes basic familiarity with Ethernet networks and architecture specifications.

Related Documentation

Table 2 - Documents List

Mellanox Firmware Tools (MFT) User Manual Document no. 2204UG
IEEE Std 802.3 Specification
PCI Express 3.0 Specifications

User Manual describing the set of MFT firmware management tools for a single node. See http://www.mellanox.com => Support => Download Firmware Tools
This is the IEEE Ethernet specification http://standards.ieee.org/getieee802
Industry Standard PCI Express 3.0 Base and Card Electromechanical Specifications

Online Resources
· Mellanox Technologies web pages: http://www.mellanox.com · Mellanox Technologies Firmware download web page:
http://www.mellanox.com => Support => Download Center
Document Conventions
When discussing memory sizes, MB and MBytes are used in this document to mean size in mega bytes. The use of Mb or Mbits (small b) indicates size in mega bits.
Technical Support
Customers who purchased Mellanox products directly from Mellanox are invited to contact us through the following methods. · URL: http://www.mellanox.com => Support · E-mail: support@mellanox.com · Tel: +1.408.916.0055 Customers who purchased Mellanox M-1 Global Support Services, please see your contract for details regarding Technical Support.

8

Mellanox Technologies

ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project

Rev 1.9

Customers who purchased Mellanox products through a Mellanox approved reseller should first seek assistance through their reseller.

Firmware and Software Updates
The Mellanox support downloader contains software, firmware and knowledge database information for Mellanox products. Access the data base from the Mellanox Support web page, http://www.mellanox.com => Support or use the following link to go directly to the Mellanox Support Download Assistant page, http://www.mellanox.com/supportdownloader/.

Mellanox Technologies 9

Rev 1.9

Overview

1 Overview
This document is a User Manual for Mellanox Technologies Ethernet Mezzanine cards based on the ConnectX®-3 EN integrated circuit device. The cards described in this manual have the following main features: · IEEE Std. 802.3 compliant · PCI Express 3.0 (1.1 and 2.0 compatible) through an x4 Mezzanine connector · PCI Express 2.0 (1.1 compatible) through an x8 Mezzanine connector · 10 Gb/s Ethernet · Single and Dual SFP+ ports card · RDMA over Converged Ethernet (RoCE) · End-to-end QoS and congestion control · Hardware-based I/O virtualization · TCP/UDP/IP stateless off-load · IPMI support · Wake-on-LAN (WoL) · Reset-on-LAN (RoL) · RoHS-R6 compliant · For MCX341A-XCBN only: Unified Extensible Firmware Interface (UEFI) support

1.1 Supported Network Protocol Standards
10 Gigabit Ethernet is an Ethernet network protocol standard for LANs specifying data transfer rate of 10Gb/s. Mellanox adapters comply with the following IEEE 802.3* standards: · IEEE Std 802.3ae 10 Gigabit Ethernet · IEEE Std 802.3ad Link Aggregation and Failover

1.2 Adapter Cards Covered in this Manual
Table 3 lists the single and dual port 10 Gigabit Ethernet adapter cards described in this manual.

Table 3 - Single and Dual-port 10 Gigabit Ethernet Adapter Card

Ordering Part Number (OPN)
MCX341AXCAN
MCX341AXCBN
MCX342AXCAN

PCI Express SERDES Speed

Data Transmis-sion Rate/
# of ports

PCIe 3.0 x4 8GT/s PCIe 2.0 x8 5GT/s

10GigE single-port SFP+

PCIe 3.0 x4 8GT/s PCIe 2.0 x8 5GT/s

10GigE single-port SFP+

PCIe 3.0 x4 8GT/s 10GigE dual-port SFP+ PCIe 2.0 x8 5GT/s

RoHS R-6 R-6 R-6

IC Part Number
MT27518A1-FCCRXE

10

Mellanox Technologies

ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project

Rev 1.9

1.3 Finding the MAC and Serial Number on the Mezzanine Card
Each Mellanox Mezzanine card has a label on the print side that shows the card serial number and the card MAC for Ethernet protocol.
Figure 1: MCX341A-XCAN Board Label

Figure 2: MCX341A-XCBN Board Label

Mellanox Technologies 11

Rev 1.9

Figure 3: MCX342A-XCAN Board Label

Overview

1.4 Safety Warnings
For safety warnings in French see "Avertissements de sécurité d'installation (Warnings in French)" on page 34. For safety warnings in German see "Sicherheitshinweise (Warnings in German)" on page 35. For safety warnings in Spanish see "Advertencias de seguridad para la instalación (Warnings in Spanish)" on page 37.
1. Installation Instructions
Read all installation instructions before connecting the equipment to the power source.
2. Over-temperature
This equipment should not be operated in an area with an ambient temperature exceeding the maximum recommended: 55°C (131°F). To guarantee proper air flow, allow at least 8cm (3 inches) of clearance around the ventilation openings.
3. During Lightning - Electrical Hazard
During periods of lightning activity, do not work on the equipment or connect or disconnect cables.

12

Mellanox Technologies

ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project
4. Equipment Disposal

Rev 1.9

Disposal of this equipment should be in accordance to all national laws and regulations.

5. Local and National Electrical Codes

This equipment should be installed in compliance with local and national electrical codes.

6. Hazardous Radiation Exposure
Caution ­ Use of controls or adjustment or performance of procedures other than those specified herein may result in hazardous radiation exposure.

CLASS 1 LASER PRODUCT and reference to the most recent laser standards: IEC 60 825-1:1993 + A1:1997 + A2:2001 and EN 60825-1:1994+A1:1996+ A2:2001

Mellanox Technologies 13

Rev 1.9

Mezzanine Card Interfaces

2 Mezzanine Card Interfaces

2.1 I/O Interfaces
Each Mezzanine card includes the following interfaces: · PCI Express (PCIe) Mezzanine connector · SFP+ empty cage · I2C-compatible connector (optional for debug purposes) · For MCX341A-XCBN only: UEFI

2.1.1

Ethernet SFP+ Interface
The network ports of the ConnectX®-3 Mezzanine cards are compliant with the IEEE 802.3 Ethernet standards listed in Section 1.1, "Supported Network Protocol Standards," on page 10.

2.1.2

PCI Express Mezzanine Connector
The ConnectX®-3 Mezzanine card connects by means of one PCIe x8 Mezzanine card connector that holds the x8 PCIe signals from the motherboards. When connected to a PCIe Gen3 environment, firmware configures the card to use 4 lanes upon bring up.

2.1.3

I2C-compatible Interface
A three-pin header on the Mezzanine cards is provided as the I2C-compatible interface. See Figure 9, "Mechanical Drawing of the Single-port MCX341A-XC[AB]N Mezzanine Card," on page 30 for the location on the board.

Figure 4: I2C-compatible Connector

2.1.4

Unified Extensible Firmware Interface (UEFI)
The UEFI driver is located on the device option ROM and can be used for network boot (for example remote OS installation).

2.2 Power
All Mezzanine cards receive 5V and 3.3V power from the PCI Express Mezzanine connector. All other required power voltages are generated by on-board switch mode regulators. See "Specifications" on page 27.

2.3 Memory
The Mezzanine cards support multiple memory devices through the PCIe, SPI (Flash) and I2C interfaces.

14

Mellanox Technologies

ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project

Rev 1.9

2.3.1

System Memory
The Mezzanine cards utilize the PCI Express interface to store and access Ethernet fabric connection information and packet data on the system memory.

2.3.2

SPI
Each of the Mezzanine cards includes one 16MB SPI Flash device (M25PX16-VMN6P device by ST Microelectronics) accessible via the SPI interface of the ConnectX®-3 EN device.
There is a jumper on each Mezzanine card that indicates to the device whether an on-board Flash device is to be used or not. Table 4 provides information on this jumper.

Table 4 - Jumper Configuration

Description
Flash present/ not present

Option
connection open ­ Flash present connection shorted ­ Flash not present

Card Default Configuration
connection open ­ Flash present

2.3.3

EEPROM
Each board incorporates an EEPROM that is accessible through the I2C-compatible interface. The EEPROM capacity is 4Kb. The EEPROM is used for storing the Vital Product Data (VPD).
The PCI VPD (Vital Product Data) layout for each of the Mezzanine cards complies with the format defined in the PCI 3.0 Specification, Appendix I.

Table 5 - MCX342A-XCAN VPD Layout

Offset (Decimal)
0
1 2 3

Item
Large Resource Type ID String Tag (0x02) Length [7:0] LSB Length [15:8] MSB Data

27

Large Resource Type VPD-R

Tag (0x10)

28

Length [7:0] LSB

29

Length [15:8] MSB

30

VPD Keyword

32

Length

33

Part Number

Value
0x82
0x18 0x0 CX354A - ConnectX-3 QSFP 0x90
0x4F 0x00 PN 0x15 PN

Format
STR
STR %STR_SPC

Description
Add in Card Part Number

Mellanox Technologies 15

Rev 1.9

Table 5 - MCX342A-XCAN VPD Layout

Offset (Decimal)
54

Item
VPD Keyword

Value
EC

56 57 59 61 62 86 88 89 105 107 108 109
110 111 112 114 115 121 123 124 148 150 151 256 258 259 512 514 515 768 770 771 1024 1026 1027 1280 1282 1283 1536 1538

Length Revision VPD Keyword Length SerialNumber VPD Keyword Length
Data VPD Keyword
Length Data Large Resource Type VPD-W Tag (0x11) Length [7:0] LSB Length [15:8] MSB VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length

0x2 RV SN 0x18 SN V0 0x10 PCIe Gen3 x8 RV 0x1 0,107 0x91
0x8F 0xF V1 0x6 N/A YA 0x18 N/A RW 0x69
RW 0xfd
RW 0xfd
RW 0xfd
RW 0xfd
RW 0xfd
RW 0xfd

16

Mellanox Technologies

Mezzanine Card Interfaces

Format
STR
%STR STR
%STR_SPC STR
STR_SPC STR
%CS0

Description
Engineering Change Level of the card (rev)
PCB revision Serial Number
"00..00XXXX..XX" Misc Information

STR
STR_SPC STR
STR_SPC STR
STR_ZERO STR
STR_ZERO STR
STR_ZERO STR
STR_ZERO STR
STR_ZERO STR
STR_ZERO STR

EFI Driver version
Asset Tag
"N/A" Remaining read/write area
Reserved (0x00) Remaining read/write area
Reserved (0x00) Remaining read/write area
Reserved (0x00) Remaining read/write area
Reserved (0x00) Remaining read/write area
Reserved (0x00) Remaining read/write area
Reserved (0x00) Remaining read/write area

ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project

Table 5 - MCX342A-XCAN VPD Layout

Offset (Decimal)
1539 1792 1794 1795 2048 2050 2051 2304 2306 2307 2560 2562 2563 2816 2818 2819 3072 3074 3075 3328 3330 3331 3584 3586 3587 3840 3842 3843 4095

Item
Data VPD Keyword
Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data Small Resource Type END Tag (0x11)

Value
RW 0xfd
RW 0xfd
RW 0xfd
RW 0xfd
RW 0xfd
RW 0xfd
RW 0xfd
RW 0xfd
RW 0xfc
0x78

Format
STR_ZERO STR
STR_ZERO STR
STR_ZERO STR
STR_ZERO STR
STR_ZERO STR
STR_ZERO STR
STR_ZERO STR
STR_ZERO STR
STR_ZERO STR
STR_ZERO

Rev 1.9
Description
Reserved (0x00) Remaining read/write area
Reserved (0x00) Remaining read/write area
Reserved (0x00) Remaining read/write area
Reserved (0x00) Remaining read/write area
Reserved (0x00) Remaining read/write area
Reserved (0x00) Remaining read/write area
Reserved (0x00) Remaining read/write area
Reserved (0x00) Remaining read/write area
Reserved (0x00) Remaining read/write area
Reserved (0x00)

Table 6 - MCX341A-XC[AB]N VPD Layout

Offset (Decimal)
0
1 2 3

Item
Large Resource Type ID String Tag (0x02) Length [7:0] LSB Length [15:8] MSB Data

27

Large Resource Type VPD-R

Tag (0x10)

28

Length [7:0] LSB

Value
0x82
0x18 0x0 CX341A - ConnectX-3 SFP+ 0x90
0x4F

Format

Description

STR

Mellanox Technologies 17

Rev 1.9

Table 6 - MCX341A-XC[AB]N VPD Layout

Offset (Decimal)
29 30 32 33 54

Item
Length [15:8] MSB VPD Keyword Length Part Number VPD Keyword

Value
0x00 PN 0x15 PN EC

56 57 59 61 62 86 88 89 105 107 108 109
110 111 112 114 115 121 123 124 148 150 151 256 258 259 512 514 515 768 770 771 1024 1026 1027 1280

Length Revision VPD Keyword Length SerialNumber VPD Keyword Length
Data VPD Keyword
Length Data Large Resource Type VPD-W Tag (0x11) Length [7:0] LSB Length [15:8] MSB VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword

0x2 RV SN 0x18 SN V0 0x10 PCIe Gen3 x8 RV 0x1 0,107 0x91
0x8F 0xF V1 0x6 N/A YA 0x18 N/A RW 0x69
RW 0xfd
RW 0xfd
RW 0xfd
RW 0xfd
RW

18

Mellanox Technologies

Mezzanine Card Interfaces

Format

Description

STR
%STR_SPC STR
%STR STR
%STR_SPC STR
STR_SPC STR
%CS0

Add in Card Part Number
Engineering Change Level of the card (rev)
PCB revision Serial Number
"00..00XXXX..XX" Misc Information

STR
STR_SPC STR
STR_SPC STR
STR_ZERO STR
STR_ZERO STR
STR_ZERO STR
STR_ZERO STR
STR_ZERO STR

EFI Driver version
Asset Tag
"N/A" Remaining read/write area
Reserved (0x00) Remaining read/write area
Reserved (0x00) Remaining read/write area
Reserved (0x00) Remaining read/write area
Reserved (0x00) Remaining read/write area
Reserved (0x00) Remaining read/write area

ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project

Table 6 - MCX341A-XC[AB]N VPD Layout

Offset (Decimal)
1282 1283 1536 1538 1539 1792 1794 1795 2048 2050 2051 2304 2306 2307 2560 2562 2563 2816 2818 2819 3072 3074 3075 3328 3330 3331 3584 3586 3587 3840 3842 3843 4095

Item
Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data Small Resource Type END Tag (0x11)

Value
0xfd
RW 0xfd
RW 0xfd
RW 0xfd
RW 0xfd
RW 0xfd
RW 0xfd
RW 0xfd
RW 0xfd
RW 0xfd
RW 0xfc
0x78

Format
STR_ZERO STR
STR_ZERO STR
STR_ZERO STR
STR_ZERO STR
STR_ZERO STR
STR_ZERO STR
STR_ZERO STR
STR_ZERO STR
STR_ZERO STR
STR_ZERO STR
STR_ZERO

Rev 1.9
Description
Reserved (0x00) Remaining read/write area
Reserved (0x00) Remaining read/write area
Reserved (0x00) Remaining read/write area
Reserved (0x00) Remaining read/write area
Reserved (0x00) Remaining read/write area
Reserved (0x00) Remaining read/write area
Reserved (0x00) Remaining read/write area
Reserved (0x00) Remaining read/write area
Reserved (0x00) Remaining read/write area
Reserved (0x00) Remaining read/write area
Reserved (0x00)

Mellanox Technologies 19

Rev 1.9

Ethernet Mezzanine Card Installation

3 Ethernet Mezzanine Card Installation

3.1 Hardware Requirements
This card requires a PCI Express connector as specified in the Open Compute Project Intel Motherboard spec v2.0.
3.2 Installation Instructions
Read all installation instructions before connecting the equipment to the power source. The cards require a PCI Express x4 or x8 Mezzanine connector. Please consult the host machine documentation for instructions on how to install a PCI Express Mezzanine connector.
If the card is installed in a PCI Mezzanine connector with less lanes than the card requires then the Mezzanine card will not provide the optimum data transfer.

3.3 Identify the Card in Your System

3.3.1

On Windows
1. Open Device Manager on the server. Click start => Run, and then enter "devmgmt.msc". 2. Expand System Devices and locate your Mellanox ConnectX-3 Mezzanine card. 3. Select Properties to display the Mezzanine card properties window. 4. Click the Details tab and select Device Instance Id (Windows 2003) or
Hardware Ids (Windows 2008/R2) from the Property pull-down menu.

Figure 5: PCI Device

5. In the Value display box, check the fields VEN and DEV (fields are separated by `&'). In the display example above, notice the sub-string "PCI\VEN_15B3&DEV_1003": VEN is equal

20

Mellanox Technologies

ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project

Rev 1.9

to 0x15B3 ­ this is the Vendor ID of Mellanox Technologies; and DEV is equal to 1003 ­ this is a valid Mellanox Technologies PCI Device ID.

If the PCI device does not have a Mellanox Mezzanine ID, return to Step 4 to check another device.

The list of Mellanox Technologies PCI Device IDs can be found in the PCI ID repository at http://pci-ids.ucw.cz/read/PC/15b3.

3.3.2

On Linux
Get the device location on the PCI bus by running lspci and locating lines with the string "Mellanox Technologies":

> lspci |grep -i Mellanox 27:00.0 Network controller: Mellanox Technologies MT27500 Family [ConnectX-3]
3.4 Cables and Modules
The SFP+ port can connect to the Ethernet through both direct attach cables and stand alone transceivers with optical cables. SFP+ transceiver modules are available for both SR and LR protocols. See www.mellanox.com => Products => Cables & Modules for certified and approved cable recommendations.
Note: In order to support SFP+ transceiver modules, the host must supply 3.3Vaux = 3.3V -3% / +5%, or use 3.3V -7% tolerant modules.

Mellanox Technologies 21

Rev 1.9

Driver Software and Firmware

4 Driver Software and Firmware

4.1 Driver Software

4.1.1

Linux
For Linux, download and install the latest MLNX_EN driver software package available via the Mellanox web site at: http://www.mellanox.com => Products => Software => Ethernet Drivers => ConnectX® EN 10GigE Linux Driver => Download. Follow the installation instructions included in the download package (also available from the download page). To ensure that communication has been established follow the instructions below.
To assign an IP address to the interface run:
> ifconfig eth<x> <ip>

where 'x' is the OS assigned interface number. To check driver and device information run:
> ethtool -i eth<x>

Example:
> ethtool -i eth2 driver:mlx4_en (MT_1020110019_CX-3) version: 1.5.6.33 (Oct 2011) firmware-version:2.10.0000 bus-info: 0000:07:00.0

4.1.2

Windows
For Windows, download the MLNX EN ­ Ethernet driver. Download this package from the Mellanox web site at: http://www.mellanox.com => Products => Software => Ethernet Drivers => ConnectX® EN 10GigE Windows Driver => Download. Follow the installation instructions included in the download package (also available from the download page). To ensure that communication has been established follow the instructions below.
To display a summary of network Mezzanine software-, firmware- and hardware-related information such as driver version, firmware version, bus interface, Mezzanine identity, and network port link information, perform the following steps:

Step 1: Display the Device Manager

22

Mellanox Technologies

ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project
Figure 6: Device Manager

Rev 1.9

Step 2: Right-click a Mellanox ConnectX-3 Ethernet adapter (under "Network adapters list) and left-click Properties.
Step 3: Select the Information tab from the Properties sheet.

To save this information for debug purposes, click Save To File and provide the output file name.
Mellanox Technologies 23

Rev 1.9

Driver Software and Firmware

4.2 VMware
For VMware download and install the latest Mellanox OFED Driver for VMware® ESXi Serversoftware package available via the Mellanox web site at: http://www.mellanox.com => Products => Software => Ethernet Drivers => ConnectX® EN 10GbE Driver for VMware® ESX Server => Download. Follow the installation instructions included in the download package (also available from the download page).

4.3 FlexBoot
Mellanox FlexBoot is a multiprotocol remote boot technology. FlexBoot supports remote Boot remote boot over Ethernet, Boot over Ethernet (BoE) or Boot over iSCSI (Bo-iSCSI). Using Mellanox Virtual Protocol Interconnect (VPI) technologies available in ConnectX® adapters, FlexBoot gives IT Managers' the choice to boot from a remote storage target (iSCSI target) or a LAN target (Ethernet Remote Boot Server) using a single ROM image on Mellanox ConnectX products.This technology is based on the Preboot Execution Environment (PXE) standard specification, and FlexBoot software is based on the open source iPXE project (see www.ipxe.org). For more information go to http://www.mellanox.com=> Products => Software => Ethernet Drivers => FlexBoot => Download.

4.4 RDMA over Converged Ethernet
ConnectX®-3 connected to an Ethernet fabric provides all of the basic NIC functionality plus RDMA over Converged Ethernet (RoCE). RoCE utilizes advances in Data Center Bridging (DCB) to enable efficient and low cost implementations of RDMA over Ethernet, supporting the entire breadth of RDMA and low latency features. This includes reliable connected service, datagram service, RDMA and send/receive semantics, atomic operations, user level multicast, user level I/O access, kernel bypass, and zero copy. This capability is enabled when using the Mellanox OFED or WinOF VPI drivers.
ConnectX®-3 EN with RoCE based network management is the same as that for any Ethernet and DCB-based network management, eliminating the need for IT managers to learn new technologies.

4.4.1

Hardware and Software Requirements
Software: · Mellanox OFED 1.5.3 or WinOF VPI 4.5or later Hardware: · ConnectX®-3 Mezzanine card

4.5 Updating Mezzanine Card Firmware
Each card is shipped with the latest version of qualified firmware at the time of manufacturing. Firmware is updated occasionally, and the most recent firmware can be obtained from: http://www.mellanox.com => Support => Download Firmware. Check that the firmware on your card is the latest found on the Mellanox site, if not update to the latest version found on the Mellanox web site.
Firmware can be updated on the stand alone single card using the flint tool of the Mellanox Firmware Tools (MFT) package. This package is available for download, along with its user manual,

24

Mellanox Technologies

ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project

Rev 1.9

from the Mellanox Firmware Tools page. See http://www.mellanox.com => Products => Software => Ethernet Drivers => Firmware Tools.
A firmware binaries table lists a binary file per Mezzanine card. The file name of each such binary is composed by combining the firmware name, the firmware release version, and the card part number. Please contact Mellanox System Support if you cannot find the firmware binary for your Mezzanine card.
The following steps describe how to retrieve the PSID (firmware identification) and programmed firmware version of your Mezzanine card. They also describe how to update the card with the latest firmware version available.
1. Retrieve the PSID and firmware version:
a. Install the MFT package. The package is available at http://www.mellanox.com => Products Software => Ethernet Drivers => => Firmware Tools. Make sure to download the package corresponding to your computer's operating system.
a. Enter: mst start.
b. Get the Mellanox mst device name using the command "mst status". The mst device name will be of the form: /dev/mst/mt4099_pci_cr0.
c. Get the PSID (firmware identification) and programmed firmware version using the command.

> flint -d /dev/mst/mt4099_pci_cr0 q

Image type: ConnectX

FW Version: 2.9.4000

Device ID:

4099

Chip Revision: 0

Description: Node

Port1

Port2

Sys image

GUIDs:

000002c900000200 000002c900000201 000002c900000202

000002c900000203

MACs:

000002c90200

000002c90201

Board ID:

(MT_1020110019)

VSD:

PSID:

MT_1020110019

2. Compare the programmed firmware version with the latest available.
a. Go to Mellanox's web site: http://www.mellanox.com/supportdownloader. See Figure 7.
d. Enter your card PSID to display the latest firmware.

Mellanox Technologies 25

Rev 1.9

Figure 7: Support Download Assistant

Driver Software and Firmware

3. If a newer firmware version exists for your Mezzanine card, update the firmware as follows:
a. Download the firmware image zip file from the Download Center (see Step 2a above).
e. Unzip the firmware image. f. Burn the firmware image. Enter:

> flint -d /dev/mst/mt4099_pci_cr0 -i <binary image> burn

g. Reboot the computer. h. Enter: mst start. i. Verify that the card firmware was updated successfully.

> flint -d /dev/mst/mt4099_pci_cr0 q

Image type: ConnectX

FW Version: 2.9.4100

Device ID:

4099

...

26

Mellanox Technologies

ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project
Appendix A: Specifications

A.1

MCX342A-XCAN Specifications

Table 7 - MCX342A-XCAN Specifications Table

Physical

Size: 2.68in. x 4.3 in. (68mm x 110mm) Connector: SFP+ 10Gb/s

Rev 1.9

Ethernet: 10GBASE-SR, 10GBASE-LR, and 10GBASE-CX

Protocol Support Data Rate: 1/10Gb/s ­ Ethernet

PCI Express Gen3: SERDES @ 8.0GT/s, 4 lanes (2.0 and 1.1 compatible) PCI Express Gen2: SERDES @ 5.0GT/s, 8 lanes (1.1 compatible)
Voltage: 5V, 3.3V
Typ Power: PCIe x4 Gen3 Passive Cables 3.95W

PCIe x8 Gen2 Passive Cables 4.97W

Power and Environmental

Max Power: PCIe x4 Gen3 Passive Cables 5.33W
PCIe x8 Gen2 Passive Cables 6.24W

Temperature: Operational: 0°C to 45°C Non-operational: 0°C to 70°C

Humidity: 90% relative humiditya

Air Flow: 200LFMb

EMC: Refer to the following link: www.mellanox.com/related-docs/user_manuals/ Regulatory_and_Compliance_Guide.pdf

Regulatory

Safety: IEC/EN 60950-1:2006 ETSI EN 300 019-2-2 IEC 60068-2- 64, 29, 32

RoHS: RoHS-R6

Cable Support

Please refer to "Mellanox Products Approved Cable Lists" at: www.mellanox.com/related-docs/user_manuals/Mellanox_approved_cables.pdf

a. For both operational and non-operational states b. Air flow is measured ~1" from the heat sink between the heat sink and the cooling air inlet.

Mellanox Technologies 27

Rev 1.9

A.2

MCX341A-XC[AB]N Specifications

Table 8 - MCX341A-XC[AB]N Specifications Table

Physical

Size: 2.68in. x 4.3 in. (68mm x 110mm) Connector: SFP+ 10Gb/s

Ethernet: 10GBASE-SR, 10GBASE-LR, and 10GBASE-CX

Protocol Support Data Rate: 1/10Gb/s ­ Ethernet

PCI Express Gen3: SERDES @ 8.0GT/s, 4 lanes (2.0 and 1.1 compatible) PCI Express Gen2: SERDES @ 5.0GT/s, 8 lanes (1.1 compatible)
Voltage: 5V, 3.3V
Typ Power: PCIe x4 Gen3 Passive Cables 3.72W

PCIe x8 Gen2 Passive Cables 4.79W

Power and Environmental

Max Power: PCIe x4 Gen3 Passive Cables 5.10W
PCIe x8 Gen2 Passive Cables 5.91W

Temperature: Operational: 0°C to 45°C Non-operational: 0°C to 70°C

Humidity: 90% relative humiditya

Air Flow: 200LFMb

EMC: Refer to the following link: www.mellanox.com/related-docs/user_manuals/ Regulatory_and_Compliance_Guide.pdf

Regulatory

Safety: IEC/EN 60950-1:2006 ETSI EN 300 019-2-2 IEC 60068-2- 64, 29, 32

RoHS: RoHS-R6

Cable Support

Please refer to "Mellanox Products Approved Cable Lists" at: www.mellanox.com/related-docs/user_manuals/Mellanox_approved_cables.pdf

a. For both operational and non-operational states b. Air flow is measured ~1" from the heat sink between the heat sink and the cooling air inlet.

28

Mellanox Technologies

ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project
A.3 Board Mechanical Drawing and Dimensions
All dimensions are in millimeters. All the mechanical tolerances are +/- 0.1mm

Rev 1.9

Figure 8: Mechanical Drawing of the Dual-port MCX342A-XCAN Mezzanine Card

42.05

Mellanox Technologies 29

Rev 1.9
Figure 9: Mechanical Drawing of the Single-port MCX341A-XC[AB]N Mezzanine Card
42.05
A.4 Regulatory Statements
For regulatory statements for all ConnectX®-3 cards please refer to: http://www.mellanox.com/related-docs/user_manuals/Regulatory_and_Compliance_Guide.pdf

30

Mellanox Technologies

ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project
Appendix B: Interface Connectors Pinout

Rev 1.9

B.1 I2C-compatible Connector Pinout
Figure 10: Compatible Connector Plug and Pinout Table 9 - I2C-compatible Connector Pinout

Connector Pin Number 1 2 3

Signal Name SPSDA SPSCL GND

B.2 PCI Express x4 Connector Pinout
The Mezzanine cards use a standard PCI Express x4 Mezzanine connector and the PCI Express x4 standard pinout according to the PCI Express 3.0 specification. The card also uses a standard PCI Express x8 Mezzanine connector and the PCI Express x8 standard pinout according to the PCI Express 2.0 specification.

Mellanox Technologies 31

Rev 1.9

Figure 11: PCIe Connector Pinout

32

Mellanox Technologies

ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project
B.3 SFP+ Pinout
Figure 12: SFP+ Cage Pinout

Rev 1.9

Mellanox Technologies 33

Rev 1.9
Appendix C: Avertissements de sécurité d'installation (Warnings in French)
1. Instructions d'installation
Lisez toutes les instructions d'installation avant de brancher le matériel à la source d'alimentation électrique.
2. Température excessive
Ce matériel ne doit pas fonctionner dans une zone avec une température ambiante dépassant le maximum recommandé de 55°C (131°F). Un flux d'air de 200LFM à cette température ambiante maximale est nécessaire. En outre, pour garantir un bon écoulement de l'air, laissez au moins 8 cm (3 pouces) d'espace libre autour des ouvertures de ventilation.
3. Orages ­ dangers électriques
Pendant un orage, il ne faut pas utiliser le matériel et il ne faut pas brancher ou débrancher les câbles.
4. Installation du matériel
Ce matériel ne doit être installé, remplacé ou entretenu que par du personnel formé et qualifié.
5. Elimination du matériel
L'élimination de ce matériel doit s'effectuer dans le respect de toutes les législations et réglementations nationales en vigueur.
6. Codes électriques locaux et nationaux
Ce matériel doit être installé dans le respect des codes électriques locaux et nationaux.
7. Exposition au rayonnement grave Mise en garde ­ l'utilisation de commandes ou de réglages ou l'exécution de procédures autres que ce qui est spécifié dans les présentes peut engendrer une exposition au rayonnement grave.
PRODUIT LASER DE CLASSE 1 » et références aux normes laser les plus récentes CEI 60 825-1:1993 + A1:1997 + A2:2001 et NE 608251:1994+A1:1996+ A2:2001

34

Mellanox Technologies

ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project

Rev 1.9

Appendix D: Sicherheitshinweise (Warnings in German)

1. Installationsanleitungen
Lesen Sie alle Installationsanleitungen, bevor Sie das Gerät an die Stromversorgung anschließen.
2. Übertemperatur
Dieses Gerät sollte nicht in einem Bereich mit einer Umgebungstemperatur über der maximal empfohlenen Temperatur von 55°C (131°F) betrieben werden. Es ist ein Luftstrom von 200 LFM bei maximaler Umgebungstemperatur erforderlich. Außerdem sollten mindestens 8 cm (3 in.) Freiraum um die Belüftungsöffnungen sein, um einen einwandfreien Luftstrom zu gewährleisten.
3. Bei Gewitter - Elektrische Gefahr
Arbeiten Sie während eines Gewitters und Blitzschlag nicht am Gerät, schließen Sie keine Kabel an oder ab.
4. Geräteinstallation
Diese Gerät sollte nur von geschultem und qualifiziertem Personal installiert, ausgetauscht oder gewartet werden.
5. Geräteentsorgung
Die Entsorgung dieses Geräts sollte unter Beachtung aller nationalen Gesetze Bestimmungen erfolgen.
6. Regionale und nationale elektrische Bestimmungen t
Dieses Gerät sollte unter Beachtung der regionalen und nationalen elektrischen Bestimmungen installiert werden.
This equipment should be installed in compliance with local and national electrical codes.

7. Strahlenkontak Achtung ­ Nutzung von Steuerungen oder Einstellungen oder Ausführung von Prozeduren, die hier nicht spezifiziert sind, kann zu gefährlichem Strahlenkontakt führen..
Mellanox Technologies 35

Rev 1.9

Klasse 1 Laserprodukt und Referenzen zu den aktuellsten Lasterstandards : ICE 60 825-1:1993 + A1:1997 + A2:2001 und EN 60825-1:1994+A1:1996+ A2:2001

36

Mellanox Technologies

ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project

Rev 1.9

Appendix E: Advertencias de seguridad para la instalación (Warnings in Spanish)

1. Instrucciones de instalación

Antes de conectar el equipo a la fuente de alimentación, leer todas las instrucciones de instalación.

2. Sobrecalentamiento
No se debe utilizar el equipo en un área con una temperatura ambiente superior a la máxima recomendada: 55°C(131°F). Además, para garantizar una circulación de aire adecuada, se debe dejar como mínimo un espacio de 8 cm (3 pulgadas) alrededor de las aberturas de ventilación.
3. Cuando hay rayos: peligro de descarga eléctrica

No utilizar el equipo ni conectar o desconectar cables durante períodos de actividad de rayos.

4. Instalación de equipos

La instalación, el reemplazo y el mantenimiento de este equipo estarán a cargo únicamente de personal capacitado y competente.

5. Eliminación de equipos

La eliminación definitiva de este equipo se debe efectuar conforme a todas las leyes y reglamentaciones nacionales.

6. Códigos eléctricos locales y nacionales

Este equipo se debe instalar conforme a los códigos eléctricos locales y nacionales.

7. Exposición a niveles de radiación peligrosos
Precaución: el uso de controles o ajustes o la realización de procedimientos distintos de los que aquí se especifican podrían causar exposición a niveles de radiación peligrosos.

PRODUCTO LÁSER DE CLASE 1 y referencia a las normas de láser más recientes: IEC 60825-1:2007/03 y EN 60825-1:2007

Mellanox Technologies 37


Acrobat Distiller 10.1.5 (Windows)