This manual is intended for the installer and user of these cards. The manual assumes basic familiarity with Ethernet networks and architecture specifications. Related ation
.mellanox.com => Products Software =>. Ethernet Drivers => => Firmware Tools. Make sure to download the package corresponding to your com- puter's operating system. a. Enter: mst ...
This manual is intended for the installer and user of these cards. ... ConnectX -3 Ethernet Single and Dual SFP Ports Mezzanine Card User Manual for Open Compute Project.
ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project P/N: MCX341A-XCAN, MCX341A-XCBN, MCX342A-XCAN Rev 1.9 www.mellanox.com Rev 1.9 NOTE: THIS HARDWARE, SOFTWARE OR TEST SUITE PRODUCT ("PRODUCT(S)") AND ITS RELATED DOCUMENTATION ARE PROVIDED BY MELLANOX TECHNOLOGIES "AS-IS" WITH ALL FAULTS OF ANY KIND AND SOLELY FOR THE PURPOSE OF AIDING THE CUSTOMER IN TESTING APPLICATIONS THAT USE THE PRODUCTS IN DESIGNATED SOLUTIONS. THE CUSTOMER'S MANUFACTURING TEST ENVIRONMENT HAS NOT MET THE STANDARDS SET BY MELLANOX TECHNOLOGIES TO FULLY QUALIFY THE PRODUCTO(S) AND/OR THE SYSTEM USING IT. THEREFORE, MELLANOX TECHNOLOGIES CANNOT AND DOES NOT GUARANTEE OR WARRANT THAT THE PRODUCTS WILL OPERATE WITH THE HIGHEST QUALITY. ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT ARE DISCLAIMED. IN NO EVENT SHALL MELLANOX BE LIABLE TO CUSTOMER OR ANY THIRD PARTIES FOR ANY DIRECT, INDIRECT, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES OF ANY KIND (INCLUDING, BUT NOT LIMITED TO, PAYMENT FOR PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY FROM THE USE OF THE PRODUCT(S) AND RELATED DOCUMENTATION EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Mellanox Technologies 350 Oakmead Parkway Suite 100 Sunnyvale, CA 94085 U.S.A. www.mellanox.com Tel: (408) 970-3400 Fax: (408) 970-3403 © Copyright 2013. Mellanox Technologies. All Rights Reserved. Mellanox®, Mellanox logo, BridgeX®, ConnectX®, CORE-Direct®, InfiniBridge®, InfiniHost®, InfiniScale®, PhyX®, SwitchX®, UFM®, Virtual Protocol Interconnect® and Voltaire® are registered trademarks of Mellanox Technologies, Ltd. Connect-IBTM, FabricITTM, MLNX-OSTM, MetroXTM, MetroDXTM, ScalableHPCTM, Unbreakable-LinkTM are trademarks of Mellanox Technologies, Ltd. All other trademarks are property of their respective owners. 2 Mellanox Technologies Document Number: 3691 ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project Rev 1.9 Table of Contents Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 List of Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 List of Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 About this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Chapter 1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 1.1 Supported Network Protocol Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 1.2 Adapter Cards Covered in this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 1.3 Finding the MAC and Serial Number on the Mezzanine Card . . . . . . . . . . . . . . . 11 1.4 Safety Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Chapter 2 Mezzanine Card Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2.1 I/O Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2.1.1 Ethernet SFP+ Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2.1.2 PCI Express Mezzanine Connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2.1.3 I2C-compatible Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2.1.4 Unified Extensible Firmware Interface (UEFI) . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2.2 Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2.3 Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2.3.1 System Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 2.3.2 SPI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 2.3.3 EEPROM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Chapter 3 Ethernet Mezzanine Card Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 3.1 Hardware Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 3.2 Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 3.3 Identify the Card in Your System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 3.3.1 On Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 3.3.2 On Linux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 3.4 Cables and Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Chapter 4 Driver Software and Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 4.1 Driver Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 4.1.1 Linux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 4.1.2 Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 4.2 VMware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 4.3 FlexBoot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 4.4 RDMA over Converged Ethernet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 4.4.1 Hardware and Software Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 4.5 Updating Mezzanine Card Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Appendix A Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Appendix B Interface Connectors Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Appendix C Avertissements de sécurité d'installation (Warnings in French) . . . . . . . . . . . . . 34 Appendix D Advertencias de seguridad para la instalación (Warnings in Spanish) . . . . . . . 37 Mellanox Technologies 3 Rev 1.9 List of Figures Figure 1: MCX341A-XCAN Board Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Figure 2: MCX341A-XCBN Board Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Figure 3: MCX342A-XCAN Board Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Figure 4: I2C-compatible Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Figure 5: PCI Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Figure 6: Device Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Figure 7: Support Download Assistant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Figure 8: Mechanical Drawing of the Dual-port MCX342A-XCAN Mezzanine Card . . . . . . . . . . 29 Figure 9: Mechanical Drawing of the Single-port MCX341A-XC[AB]N Mezzanine Card . . . . . . 30 Figure 10: Compatible Connector Plug and Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Figure 11: PCIe Connector Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Figure 12: SFP+ Cage Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 4 Mellanox Technologies ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project List of Tables Table 1: Table 2: Table 3: Table 4: Table 5: Table 6: Table 7: Table 8: Table 9: Revision History Table 6 Documents List 8 Single and Dual-port 10 Gigabit Ethernet Adapter Card 10 Jumper Configuration 15 MCX342A-XCAN VPD Layout 15 MCX341A-XC[AB]N VPD Layout 17 MCX342A-XCAN Specifications Table 27 MCX341A-XC[AB]N Specifications Table 28 I2C-compatible Connector Pinout 31 Rev 1.9 Mellanox Technologies 5 Rev 1.9 Revision History This document was printed on February 19, 2013. Table 1 - Revision History Table Date Rev Comments/Changes February 2013 December 2012 October 2012 September 2012 September 2012 July 2012 May 2012 1.9 · Added Section 4.2, "VMware," on page 24 · Updated Figure 5, "PCI Device," on page 20 and Figure 6, "Device Manager," on page 23 · Updated all Web links 1.8 · Updated labels in Figure 1, "MCX341A-XCAN Board Label," on page 11, Figure 2, "MCX341A-XCBN Board Label," on page 11 and Figure 3, "MCX342A-XCAN Board Label," on page 12 · Added "Cable Support" to Appendix A.1, "MCX342A- XCAN Specifications," on page 27 and Appendix A.2, "MCX341A-XC[AB]N Specifications," on page 28 1.7 · Updated mechanical drawings removing unused components. See Appendix A.3, "Board Mechanical Drawing and Dimensions," on page 29 1.6 · Fixed dimensions in Figure 8, "Mechanical Drawing of the Dual-port MCX342A-XCAN Mezzanine Card," on page 29 and Figure 9, "Mechanical Drawing of the Single- port MCX341A-XC[AB]N Mezzanine Card," on page 30 1.5 · Added operational and non-operational temperature and humid- ity level to Table 7, "MCX342A-XCAN Specifications Table," on page 27 and Table 8, "MCX341A-XC[AB]N Specifications Table," on page 28 1.4 · Added OPN MCX341A-XCBN to the following locations: · Chapter 1,"Overview" on page 10 · Table 3, "Single and Dual-port 10 Gigabit Ethernet Adapter Card," on page 10 · Figure 2, "MCX341A-XCBN Board Label," on page 11 · Table 6, "MCX341A-XC[AB]N VPD Layout," on page 17 · Appendix A.2, "MCX341A-XC[AB]N Specifications," on page 28 · Figure 9, "Mechanical Drawing of the Single-port MCX341A-XC[AB]N Mezzanine Card," on page 30 · Added new board label of the MCX341A-XCAN Mezz card. See Figure 1, "MCX341A-XCAN Board Label," on page 11. · Added Section 2.1.4, "Unified Extensible Firmware Inter- face (UEFI)," on page 14 1.3 · Updated Figure 1, "MCX341A-XCAN Board Label," on page 11 to show board revision at A3 6 Mellanox Technologies ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project Rev 1.9 Date April 2012 March 2012 November 2011 Rev Comments/Changes 1.2 · Added note on SFP+ transceiver modules to Section 3.4, "Cables and Modules," on page 21 · Updated Figure 8, "Mechanical Drawing of the Dual-port MCX342A-XCAN Mezzanine Card," on page 29 · Added Figure 9, "Mechanical Drawing of the Single-port MCX341A-XC[AB]N Mezzanine Card," on page 30 1.1 · Added Section 1.2, "Adapter Cards Covered in this Man- ual," on page 10 · Added new board labels to Section 1.3, "Finding the MAC and Serial Number on the Mezzanine Card," on page 11 · Updated Section 4.1.1, "Linux," on page 22 1.0 First Release Mellanox Technologies 7 Rev 1.9 About this Manual This User Manual describes Mellanox Technologies ConnectX®-3 10 Gigabit Ethernet Single and Dual SFP+ Port PCI Express x4 Mezzanine cards. It provides details as to the interfaces of the board, specifications, required software and firmware for operating the board, and relevant documentation. Intended Audience This manual is intended for the installer and user of these cards. The manual assumes basic familiarity with Ethernet networks and architecture specifications. Related Documentation Table 2 - Documents List Mellanox Firmware Tools (MFT) User Manual Document no. 2204UG IEEE Std 802.3 Specification PCI Express 3.0 Specifications User Manual describing the set of MFT firmware management tools for a single node. See http://www.mellanox.com => Support => Download Firmware Tools This is the IEEE Ethernet specification http://standards.ieee.org/getieee802 Industry Standard PCI Express 3.0 Base and Card Electromechanical Specifications Online Resources · Mellanox Technologies web pages: http://www.mellanox.com · Mellanox Technologies Firmware download web page: http://www.mellanox.com => Support => Download Center Document Conventions When discussing memory sizes, MB and MBytes are used in this document to mean size in mega bytes. The use of Mb or Mbits (small b) indicates size in mega bits. Technical Support Customers who purchased Mellanox products directly from Mellanox are invited to contact us through the following methods. · URL: http://www.mellanox.com => Support · E-mail: support@mellanox.com · Tel: +1.408.916.0055 Customers who purchased Mellanox M-1 Global Support Services, please see your contract for details regarding Technical Support. 8 Mellanox Technologies ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project Rev 1.9 Customers who purchased Mellanox products through a Mellanox approved reseller should first seek assistance through their reseller. Firmware and Software Updates The Mellanox support downloader contains software, firmware and knowledge database information for Mellanox products. Access the data base from the Mellanox Support web page, http://www.mellanox.com => Support or use the following link to go directly to the Mellanox Support Download Assistant page, http://www.mellanox.com/supportdownloader/. Mellanox Technologies 9 Rev 1.9 Overview 1 Overview This document is a User Manual for Mellanox Technologies Ethernet Mezzanine cards based on the ConnectX®-3 EN integrated circuit device. The cards described in this manual have the following main features: · IEEE Std. 802.3 compliant · PCI Express 3.0 (1.1 and 2.0 compatible) through an x4 Mezzanine connector · PCI Express 2.0 (1.1 compatible) through an x8 Mezzanine connector · 10 Gb/s Ethernet · Single and Dual SFP+ ports card · RDMA over Converged Ethernet (RoCE) · End-to-end QoS and congestion control · Hardware-based I/O virtualization · TCP/UDP/IP stateless off-load · IPMI support · Wake-on-LAN (WoL) · Reset-on-LAN (RoL) · RoHS-R6 compliant · For MCX341A-XCBN only: Unified Extensible Firmware Interface (UEFI) support 1.1 Supported Network Protocol Standards 10 Gigabit Ethernet is an Ethernet network protocol standard for LANs specifying data transfer rate of 10Gb/s. Mellanox adapters comply with the following IEEE 802.3* standards: · IEEE Std 802.3ae 10 Gigabit Ethernet · IEEE Std 802.3ad Link Aggregation and Failover 1.2 Adapter Cards Covered in this Manual Table 3 lists the single and dual port 10 Gigabit Ethernet adapter cards described in this manual. Table 3 - Single and Dual-port 10 Gigabit Ethernet Adapter Card Ordering Part Number (OPN) MCX341AXCAN MCX341AXCBN MCX342AXCAN PCI Express SERDES Speed Data Transmis-sion Rate/ # of ports PCIe 3.0 x4 8GT/s PCIe 2.0 x8 5GT/s 10GigE single-port SFP+ PCIe 3.0 x4 8GT/s PCIe 2.0 x8 5GT/s 10GigE single-port SFP+ PCIe 3.0 x4 8GT/s 10GigE dual-port SFP+ PCIe 2.0 x8 5GT/s RoHS R-6 R-6 R-6 IC Part Number MT27518A1-FCCRXE 10 Mellanox Technologies ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project Rev 1.9 1.3 Finding the MAC and Serial Number on the Mezzanine Card Each Mellanox Mezzanine card has a label on the print side that shows the card serial number and the card MAC for Ethernet protocol. Figure 1: MCX341A-XCAN Board Label Figure 2: MCX341A-XCBN Board Label Mellanox Technologies 11 Rev 1.9 Figure 3: MCX342A-XCAN Board Label Overview 1.4 Safety Warnings For safety warnings in French see "Avertissements de sécurité d'installation (Warnings in French)" on page 34. For safety warnings in German see "Sicherheitshinweise (Warnings in German)" on page 35. For safety warnings in Spanish see "Advertencias de seguridad para la instalación (Warnings in Spanish)" on page 37. 1. Installation Instructions Read all installation instructions before connecting the equipment to the power source. 2. Over-temperature This equipment should not be operated in an area with an ambient temperature exceeding the maximum recommended: 55°C (131°F). To guarantee proper air flow, allow at least 8cm (3 inches) of clearance around the ventilation openings. 3. During Lightning - Electrical Hazard During periods of lightning activity, do not work on the equipment or connect or disconnect cables. 12 Mellanox Technologies ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project 4. Equipment Disposal Rev 1.9 Disposal of this equipment should be in accordance to all national laws and regulations. 5. Local and National Electrical Codes This equipment should be installed in compliance with local and national electrical codes. 6. Hazardous Radiation Exposure Caution Use of controls or adjustment or performance of procedures other than those specified herein may result in hazardous radiation exposure. CLASS 1 LASER PRODUCT and reference to the most recent laser standards: IEC 60 825-1:1993 + A1:1997 + A2:2001 and EN 60825-1:1994+A1:1996+ A2:2001 Mellanox Technologies 13 Rev 1.9 Mezzanine Card Interfaces 2 Mezzanine Card Interfaces 2.1 I/O Interfaces Each Mezzanine card includes the following interfaces: · PCI Express (PCIe) Mezzanine connector · SFP+ empty cage · I2C-compatible connector (optional for debug purposes) · For MCX341A-XCBN only: UEFI 2.1.1 Ethernet SFP+ Interface The network ports of the ConnectX®-3 Mezzanine cards are compliant with the IEEE 802.3 Ethernet standards listed in Section 1.1, "Supported Network Protocol Standards," on page 10. 2.1.2 PCI Express Mezzanine Connector The ConnectX®-3 Mezzanine card connects by means of one PCIe x8 Mezzanine card connector that holds the x8 PCIe signals from the motherboards. When connected to a PCIe Gen3 environment, firmware configures the card to use 4 lanes upon bring up. 2.1.3 I2C-compatible Interface A three-pin header on the Mezzanine cards is provided as the I2C-compatible interface. See Figure 9, "Mechanical Drawing of the Single-port MCX341A-XC[AB]N Mezzanine Card," on page 30 for the location on the board. Figure 4: I2C-compatible Connector 2.1.4 Unified Extensible Firmware Interface (UEFI) The UEFI driver is located on the device option ROM and can be used for network boot (for example remote OS installation). 2.2 Power All Mezzanine cards receive 5V and 3.3V power from the PCI Express Mezzanine connector. All other required power voltages are generated by on-board switch mode regulators. See "Specifications" on page 27. 2.3 Memory The Mezzanine cards support multiple memory devices through the PCIe, SPI (Flash) and I2C interfaces. 14 Mellanox Technologies ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project Rev 1.9 2.3.1 System Memory The Mezzanine cards utilize the PCI Express interface to store and access Ethernet fabric connection information and packet data on the system memory. 2.3.2 SPI Each of the Mezzanine cards includes one 16MB SPI Flash device (M25PX16-VMN6P device by ST Microelectronics) accessible via the SPI interface of the ConnectX®-3 EN device. There is a jumper on each Mezzanine card that indicates to the device whether an on-board Flash device is to be used or not. Table 4 provides information on this jumper. Table 4 - Jumper Configuration Description Flash present/ not present Option connection open Flash present connection shorted Flash not present Card Default Configuration connection open Flash present 2.3.3 EEPROM Each board incorporates an EEPROM that is accessible through the I2C-compatible interface. The EEPROM capacity is 4Kb. The EEPROM is used for storing the Vital Product Data (VPD). The PCI VPD (Vital Product Data) layout for each of the Mezzanine cards complies with the format defined in the PCI 3.0 Specification, Appendix I. Table 5 - MCX342A-XCAN VPD Layout Offset (Decimal) 0 1 2 3 Item Large Resource Type ID String Tag (0x02) Length [7:0] LSB Length [15:8] MSB Data 27 Large Resource Type VPD-R Tag (0x10) 28 Length [7:0] LSB 29 Length [15:8] MSB 30 VPD Keyword 32 Length 33 Part Number Value 0x82 0x18 0x0 CX354A - ConnectX-3 QSFP 0x90 0x4F 0x00 PN 0x15 PN Format STR STR %STR_SPC Description Add in Card Part Number Mellanox Technologies 15 Rev 1.9 Table 5 - MCX342A-XCAN VPD Layout Offset (Decimal) 54 Item VPD Keyword Value EC 56 57 59 61 62 86 88 89 105 107 108 109 110 111 112 114 115 121 123 124 148 150 151 256 258 259 512 514 515 768 770 771 1024 1026 1027 1280 1282 1283 1536 1538 Length Revision VPD Keyword Length SerialNumber VPD Keyword Length Data VPD Keyword Length Data Large Resource Type VPD-W Tag (0x11) Length [7:0] LSB Length [15:8] MSB VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length 0x2 RV SN 0x18 SN V0 0x10 PCIe Gen3 x8 RV 0x1 0,107 0x91 0x8F 0xF V1 0x6 N/A YA 0x18 N/A RW 0x69 RW 0xfd RW 0xfd RW 0xfd RW 0xfd RW 0xfd RW 0xfd 16 Mellanox Technologies Mezzanine Card Interfaces Format STR %STR STR %STR_SPC STR STR_SPC STR %CS0 Description Engineering Change Level of the card (rev) PCB revision Serial Number "00..00XXXX..XX" Misc Information STR STR_SPC STR STR_SPC STR STR_ZERO STR STR_ZERO STR STR_ZERO STR STR_ZERO STR STR_ZERO STR STR_ZERO STR EFI Driver version Asset Tag "N/A" Remaining read/write area Reserved (0x00) Remaining read/write area Reserved (0x00) Remaining read/write area Reserved (0x00) Remaining read/write area Reserved (0x00) Remaining read/write area Reserved (0x00) Remaining read/write area Reserved (0x00) Remaining read/write area ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project Table 5 - MCX342A-XCAN VPD Layout Offset (Decimal) 1539 1792 1794 1795 2048 2050 2051 2304 2306 2307 2560 2562 2563 2816 2818 2819 3072 3074 3075 3328 3330 3331 3584 3586 3587 3840 3842 3843 4095 Item Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data Small Resource Type END Tag (0x11) Value RW 0xfd RW 0xfd RW 0xfd RW 0xfd RW 0xfd RW 0xfd RW 0xfd RW 0xfd RW 0xfc 0x78 Format STR_ZERO STR STR_ZERO STR STR_ZERO STR STR_ZERO STR STR_ZERO STR STR_ZERO STR STR_ZERO STR STR_ZERO STR STR_ZERO STR STR_ZERO Rev 1.9 Description Reserved (0x00) Remaining read/write area Reserved (0x00) Remaining read/write area Reserved (0x00) Remaining read/write area Reserved (0x00) Remaining read/write area Reserved (0x00) Remaining read/write area Reserved (0x00) Remaining read/write area Reserved (0x00) Remaining read/write area Reserved (0x00) Remaining read/write area Reserved (0x00) Remaining read/write area Reserved (0x00) Table 6 - MCX341A-XC[AB]N VPD Layout Offset (Decimal) 0 1 2 3 Item Large Resource Type ID String Tag (0x02) Length [7:0] LSB Length [15:8] MSB Data 27 Large Resource Type VPD-R Tag (0x10) 28 Length [7:0] LSB Value 0x82 0x18 0x0 CX341A - ConnectX-3 SFP+ 0x90 0x4F Format Description STR Mellanox Technologies 17 Rev 1.9 Table 6 - MCX341A-XC[AB]N VPD Layout Offset (Decimal) 29 30 32 33 54 Item Length [15:8] MSB VPD Keyword Length Part Number VPD Keyword Value 0x00 PN 0x15 PN EC 56 57 59 61 62 86 88 89 105 107 108 109 110 111 112 114 115 121 123 124 148 150 151 256 258 259 512 514 515 768 770 771 1024 1026 1027 1280 Length Revision VPD Keyword Length SerialNumber VPD Keyword Length Data VPD Keyword Length Data Large Resource Type VPD-W Tag (0x11) Length [7:0] LSB Length [15:8] MSB VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword 0x2 RV SN 0x18 SN V0 0x10 PCIe Gen3 x8 RV 0x1 0,107 0x91 0x8F 0xF V1 0x6 N/A YA 0x18 N/A RW 0x69 RW 0xfd RW 0xfd RW 0xfd RW 0xfd RW 18 Mellanox Technologies Mezzanine Card Interfaces Format Description STR %STR_SPC STR %STR STR %STR_SPC STR STR_SPC STR %CS0 Add in Card Part Number Engineering Change Level of the card (rev) PCB revision Serial Number "00..00XXXX..XX" Misc Information STR STR_SPC STR STR_SPC STR STR_ZERO STR STR_ZERO STR STR_ZERO STR STR_ZERO STR STR_ZERO STR EFI Driver version Asset Tag "N/A" Remaining read/write area Reserved (0x00) Remaining read/write area Reserved (0x00) Remaining read/write area Reserved (0x00) Remaining read/write area Reserved (0x00) Remaining read/write area Reserved (0x00) Remaining read/write area ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project Table 6 - MCX341A-XC[AB]N VPD Layout Offset (Decimal) 1282 1283 1536 1538 1539 1792 1794 1795 2048 2050 2051 2304 2306 2307 2560 2562 2563 2816 2818 2819 3072 3074 3075 3328 3330 3331 3584 3586 3587 3840 3842 3843 4095 Item Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data VPD Keyword Length Data Small Resource Type END Tag (0x11) Value 0xfd RW 0xfd RW 0xfd RW 0xfd RW 0xfd RW 0xfd RW 0xfd RW 0xfd RW 0xfd RW 0xfd RW 0xfc 0x78 Format STR_ZERO STR STR_ZERO STR STR_ZERO STR STR_ZERO STR STR_ZERO STR STR_ZERO STR STR_ZERO STR STR_ZERO STR STR_ZERO STR STR_ZERO STR STR_ZERO Rev 1.9 Description Reserved (0x00) Remaining read/write area Reserved (0x00) Remaining read/write area Reserved (0x00) Remaining read/write area Reserved (0x00) Remaining read/write area Reserved (0x00) Remaining read/write area Reserved (0x00) Remaining read/write area Reserved (0x00) Remaining read/write area Reserved (0x00) Remaining read/write area Reserved (0x00) Remaining read/write area Reserved (0x00) Remaining read/write area Reserved (0x00) Mellanox Technologies 19 Rev 1.9 Ethernet Mezzanine Card Installation 3 Ethernet Mezzanine Card Installation 3.1 Hardware Requirements This card requires a PCI Express connector as specified in the Open Compute Project Intel Motherboard spec v2.0. 3.2 Installation Instructions Read all installation instructions before connecting the equipment to the power source. The cards require a PCI Express x4 or x8 Mezzanine connector. Please consult the host machine documentation for instructions on how to install a PCI Express Mezzanine connector. If the card is installed in a PCI Mezzanine connector with less lanes than the card requires then the Mezzanine card will not provide the optimum data transfer. 3.3 Identify the Card in Your System 3.3.1 On Windows 1. Open Device Manager on the server. Click start => Run, and then enter "devmgmt.msc". 2. Expand System Devices and locate your Mellanox ConnectX-3 Mezzanine card. 3. Select Properties to display the Mezzanine card properties window. 4. Click the Details tab and select Device Instance Id (Windows 2003) or Hardware Ids (Windows 2008/R2) from the Property pull-down menu. Figure 5: PCI Device 5. In the Value display box, check the fields VEN and DEV (fields are separated by `&'). In the display example above, notice the sub-string "PCI\VEN_15B3&DEV_1003": VEN is equal 20 Mellanox Technologies ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project Rev 1.9 to 0x15B3 this is the Vendor ID of Mellanox Technologies; and DEV is equal to 1003 this is a valid Mellanox Technologies PCI Device ID. If the PCI device does not have a Mellanox Mezzanine ID, return to Step 4 to check another device. The list of Mellanox Technologies PCI Device IDs can be found in the PCI ID repository at http://pci-ids.ucw.cz/read/PC/15b3. 3.3.2 On Linux Get the device location on the PCI bus by running lspci and locating lines with the string "Mellanox Technologies": > lspci |grep -i Mellanox 27:00.0 Network controller: Mellanox Technologies MT27500 Family [ConnectX-3] 3.4 Cables and Modules The SFP+ port can connect to the Ethernet through both direct attach cables and stand alone transceivers with optical cables. SFP+ transceiver modules are available for both SR and LR protocols. See www.mellanox.com => Products => Cables & Modules for certified and approved cable recommendations. Note: In order to support SFP+ transceiver modules, the host must supply 3.3Vaux = 3.3V -3% / +5%, or use 3.3V -7% tolerant modules. Mellanox Technologies 21 Rev 1.9 Driver Software and Firmware 4 Driver Software and Firmware 4.1 Driver Software 4.1.1 Linux For Linux, download and install the latest MLNX_EN driver software package available via the Mellanox web site at: http://www.mellanox.com => Products => Software => Ethernet Drivers => ConnectX® EN 10GigE Linux Driver => Download. Follow the installation instructions included in the download package (also available from the download page). To ensure that communication has been established follow the instructions below. To assign an IP address to the interface run: > ifconfig eth<x> <ip> where 'x' is the OS assigned interface number. To check driver and device information run: > ethtool -i eth<x> Example: > ethtool -i eth2 driver:mlx4_en (MT_1020110019_CX-3) version: 1.5.6.33 (Oct 2011) firmware-version:2.10.0000 bus-info: 0000:07:00.0 4.1.2 Windows For Windows, download the MLNX EN Ethernet driver. Download this package from the Mellanox web site at: http://www.mellanox.com => Products => Software => Ethernet Drivers => ConnectX® EN 10GigE Windows Driver => Download. Follow the installation instructions included in the download package (also available from the download page). To ensure that communication has been established follow the instructions below. To display a summary of network Mezzanine software-, firmware- and hardware-related information such as driver version, firmware version, bus interface, Mezzanine identity, and network port link information, perform the following steps: Step 1: Display the Device Manager 22 Mellanox Technologies ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project Figure 6: Device Manager Rev 1.9 Step 2: Right-click a Mellanox ConnectX-3 Ethernet adapter (under "Network adapters list) and left-click Properties. Step 3: Select the Information tab from the Properties sheet. To save this information for debug purposes, click Save To File and provide the output file name. Mellanox Technologies 23 Rev 1.9 Driver Software and Firmware 4.2 VMware For VMware download and install the latest Mellanox OFED Driver for VMware® ESXi Serversoftware package available via the Mellanox web site at: http://www.mellanox.com => Products => Software => Ethernet Drivers => ConnectX® EN 10GbE Driver for VMware® ESX Server => Download. Follow the installation instructions included in the download package (also available from the download page). 4.3 FlexBoot Mellanox FlexBoot is a multiprotocol remote boot technology. FlexBoot supports remote Boot remote boot over Ethernet, Boot over Ethernet (BoE) or Boot over iSCSI (Bo-iSCSI). Using Mellanox Virtual Protocol Interconnect (VPI) technologies available in ConnectX® adapters, FlexBoot gives IT Managers' the choice to boot from a remote storage target (iSCSI target) or a LAN target (Ethernet Remote Boot Server) using a single ROM image on Mellanox ConnectX products.This technology is based on the Preboot Execution Environment (PXE) standard specification, and FlexBoot software is based on the open source iPXE project (see www.ipxe.org). For more information go to http://www.mellanox.com=> Products => Software => Ethernet Drivers => FlexBoot => Download. 4.4 RDMA over Converged Ethernet ConnectX®-3 connected to an Ethernet fabric provides all of the basic NIC functionality plus RDMA over Converged Ethernet (RoCE). RoCE utilizes advances in Data Center Bridging (DCB) to enable efficient and low cost implementations of RDMA over Ethernet, supporting the entire breadth of RDMA and low latency features. This includes reliable connected service, datagram service, RDMA and send/receive semantics, atomic operations, user level multicast, user level I/O access, kernel bypass, and zero copy. This capability is enabled when using the Mellanox OFED or WinOF VPI drivers. ConnectX®-3 EN with RoCE based network management is the same as that for any Ethernet and DCB-based network management, eliminating the need for IT managers to learn new technologies. 4.4.1 Hardware and Software Requirements Software: · Mellanox OFED 1.5.3 or WinOF VPI 4.5or later Hardware: · ConnectX®-3 Mezzanine card 4.5 Updating Mezzanine Card Firmware Each card is shipped with the latest version of qualified firmware at the time of manufacturing. Firmware is updated occasionally, and the most recent firmware can be obtained from: http://www.mellanox.com => Support => Download Firmware. Check that the firmware on your card is the latest found on the Mellanox site, if not update to the latest version found on the Mellanox web site. Firmware can be updated on the stand alone single card using the flint tool of the Mellanox Firmware Tools (MFT) package. This package is available for download, along with its user manual, 24 Mellanox Technologies ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project Rev 1.9 from the Mellanox Firmware Tools page. See http://www.mellanox.com => Products => Software => Ethernet Drivers => Firmware Tools. A firmware binaries table lists a binary file per Mezzanine card. The file name of each such binary is composed by combining the firmware name, the firmware release version, and the card part number. Please contact Mellanox System Support if you cannot find the firmware binary for your Mezzanine card. The following steps describe how to retrieve the PSID (firmware identification) and programmed firmware version of your Mezzanine card. They also describe how to update the card with the latest firmware version available. 1. Retrieve the PSID and firmware version: a. Install the MFT package. The package is available at http://www.mellanox.com => Products Software => Ethernet Drivers => => Firmware Tools. Make sure to download the package corresponding to your computer's operating system. a. Enter: mst start. b. Get the Mellanox mst device name using the command "mst status". The mst device name will be of the form: /dev/mst/mt4099_pci_cr0. c. Get the PSID (firmware identification) and programmed firmware version using the command. > flint -d /dev/mst/mt4099_pci_cr0 q Image type: ConnectX FW Version: 2.9.4000 Device ID: 4099 Chip Revision: 0 Description: Node Port1 Port2 Sys image GUIDs: 000002c900000200 000002c900000201 000002c900000202 000002c900000203 MACs: 000002c90200 000002c90201 Board ID: (MT_1020110019) VSD: PSID: MT_1020110019 2. Compare the programmed firmware version with the latest available. a. Go to Mellanox's web site: http://www.mellanox.com/supportdownloader. See Figure 7. d. Enter your card PSID to display the latest firmware. Mellanox Technologies 25 Rev 1.9 Figure 7: Support Download Assistant Driver Software and Firmware 3. If a newer firmware version exists for your Mezzanine card, update the firmware as follows: a. Download the firmware image zip file from the Download Center (see Step 2a above). e. Unzip the firmware image. f. Burn the firmware image. Enter: > flint -d /dev/mst/mt4099_pci_cr0 -i <binary image> burn g. Reboot the computer. h. Enter: mst start. i. Verify that the card firmware was updated successfully. > flint -d /dev/mst/mt4099_pci_cr0 q Image type: ConnectX FW Version: 2.9.4100 Device ID: 4099 ... 26 Mellanox Technologies ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project Appendix A: Specifications A.1 MCX342A-XCAN Specifications Table 7 - MCX342A-XCAN Specifications Table Physical Size: 2.68in. x 4.3 in. (68mm x 110mm) Connector: SFP+ 10Gb/s Rev 1.9 Ethernet: 10GBASE-SR, 10GBASE-LR, and 10GBASE-CX Protocol Support Data Rate: 1/10Gb/s Ethernet PCI Express Gen3: SERDES @ 8.0GT/s, 4 lanes (2.0 and 1.1 compatible) PCI Express Gen2: SERDES @ 5.0GT/s, 8 lanes (1.1 compatible) Voltage: 5V, 3.3V Typ Power: PCIe x4 Gen3 Passive Cables 3.95W PCIe x8 Gen2 Passive Cables 4.97W Power and Environmental Max Power: PCIe x4 Gen3 Passive Cables 5.33W PCIe x8 Gen2 Passive Cables 6.24W Temperature: Operational: 0°C to 45°C Non-operational: 0°C to 70°C Humidity: 90% relative humiditya Air Flow: 200LFMb EMC: Refer to the following link: www.mellanox.com/related-docs/user_manuals/ Regulatory_and_Compliance_Guide.pdf Regulatory Safety: IEC/EN 60950-1:2006 ETSI EN 300 019-2-2 IEC 60068-2- 64, 29, 32 RoHS: RoHS-R6 Cable Support Please refer to "Mellanox Products Approved Cable Lists" at: www.mellanox.com/related-docs/user_manuals/Mellanox_approved_cables.pdf a. For both operational and non-operational states b. Air flow is measured ~1" from the heat sink between the heat sink and the cooling air inlet. Mellanox Technologies 27 Rev 1.9 A.2 MCX341A-XC[AB]N Specifications Table 8 - MCX341A-XC[AB]N Specifications Table Physical Size: 2.68in. x 4.3 in. (68mm x 110mm) Connector: SFP+ 10Gb/s Ethernet: 10GBASE-SR, 10GBASE-LR, and 10GBASE-CX Protocol Support Data Rate: 1/10Gb/s Ethernet PCI Express Gen3: SERDES @ 8.0GT/s, 4 lanes (2.0 and 1.1 compatible) PCI Express Gen2: SERDES @ 5.0GT/s, 8 lanes (1.1 compatible) Voltage: 5V, 3.3V Typ Power: PCIe x4 Gen3 Passive Cables 3.72W PCIe x8 Gen2 Passive Cables 4.79W Power and Environmental Max Power: PCIe x4 Gen3 Passive Cables 5.10W PCIe x8 Gen2 Passive Cables 5.91W Temperature: Operational: 0°C to 45°C Non-operational: 0°C to 70°C Humidity: 90% relative humiditya Air Flow: 200LFMb EMC: Refer to the following link: www.mellanox.com/related-docs/user_manuals/ Regulatory_and_Compliance_Guide.pdf Regulatory Safety: IEC/EN 60950-1:2006 ETSI EN 300 019-2-2 IEC 60068-2- 64, 29, 32 RoHS: RoHS-R6 Cable Support Please refer to "Mellanox Products Approved Cable Lists" at: www.mellanox.com/related-docs/user_manuals/Mellanox_approved_cables.pdf a. For both operational and non-operational states b. Air flow is measured ~1" from the heat sink between the heat sink and the cooling air inlet. 28 Mellanox Technologies ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project A.3 Board Mechanical Drawing and Dimensions All dimensions are in millimeters. All the mechanical tolerances are +/- 0.1mm Rev 1.9 Figure 8: Mechanical Drawing of the Dual-port MCX342A-XCAN Mezzanine Card 42.05 Mellanox Technologies 29 Rev 1.9 Figure 9: Mechanical Drawing of the Single-port MCX341A-XC[AB]N Mezzanine Card 42.05 A.4 Regulatory Statements For regulatory statements for all ConnectX®-3 cards please refer to: http://www.mellanox.com/related-docs/user_manuals/Regulatory_and_Compliance_Guide.pdf 30 Mellanox Technologies ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project Appendix B: Interface Connectors Pinout Rev 1.9 B.1 I2C-compatible Connector Pinout Figure 10: Compatible Connector Plug and Pinout Table 9 - I2C-compatible Connector Pinout Connector Pin Number 1 2 3 Signal Name SPSDA SPSCL GND B.2 PCI Express x4 Connector Pinout The Mezzanine cards use a standard PCI Express x4 Mezzanine connector and the PCI Express x4 standard pinout according to the PCI Express 3.0 specification. The card also uses a standard PCI Express x8 Mezzanine connector and the PCI Express x8 standard pinout according to the PCI Express 2.0 specification. Mellanox Technologies 31 Rev 1.9 Figure 11: PCIe Connector Pinout 32 Mellanox Technologies ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project B.3 SFP+ Pinout Figure 12: SFP+ Cage Pinout Rev 1.9 Mellanox Technologies 33 Rev 1.9 Appendix C: Avertissements de sécurité d'installation (Warnings in French) 1. Instructions d'installation Lisez toutes les instructions d'installation avant de brancher le matériel à la source d'alimentation électrique. 2. Température excessive Ce matériel ne doit pas fonctionner dans une zone avec une température ambiante dépassant le maximum recommandé de 55°C (131°F). Un flux d'air de 200LFM à cette température ambiante maximale est nécessaire. En outre, pour garantir un bon écoulement de l'air, laissez au moins 8 cm (3 pouces) d'espace libre autour des ouvertures de ventilation. 3. Orages dangers électriques Pendant un orage, il ne faut pas utiliser le matériel et il ne faut pas brancher ou débrancher les câbles. 4. Installation du matériel Ce matériel ne doit être installé, remplacé ou entretenu que par du personnel formé et qualifié. 5. Elimination du matériel L'élimination de ce matériel doit s'effectuer dans le respect de toutes les législations et réglementations nationales en vigueur. 6. Codes électriques locaux et nationaux Ce matériel doit être installé dans le respect des codes électriques locaux et nationaux. 7. Exposition au rayonnement grave Mise en garde l'utilisation de commandes ou de réglages ou l'exécution de procédures autres que ce qui est spécifié dans les présentes peut engendrer une exposition au rayonnement grave. PRODUIT LASER DE CLASSE 1 » et références aux normes laser les plus récentes CEI 60 825-1:1993 + A1:1997 + A2:2001 et NE 608251:1994+A1:1996+ A2:2001 34 Mellanox Technologies ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project Rev 1.9 Appendix D: Sicherheitshinweise (Warnings in German) 1. Installationsanleitungen Lesen Sie alle Installationsanleitungen, bevor Sie das Gerät an die Stromversorgung anschließen. 2. Übertemperatur Dieses Gerät sollte nicht in einem Bereich mit einer Umgebungstemperatur über der maximal empfohlenen Temperatur von 55°C (131°F) betrieben werden. Es ist ein Luftstrom von 200 LFM bei maximaler Umgebungstemperatur erforderlich. Außerdem sollten mindestens 8 cm (3 in.) Freiraum um die Belüftungsöffnungen sein, um einen einwandfreien Luftstrom zu gewährleisten. 3. Bei Gewitter - Elektrische Gefahr Arbeiten Sie während eines Gewitters und Blitzschlag nicht am Gerät, schließen Sie keine Kabel an oder ab. 4. Geräteinstallation Diese Gerät sollte nur von geschultem und qualifiziertem Personal installiert, ausgetauscht oder gewartet werden. 5. Geräteentsorgung Die Entsorgung dieses Geräts sollte unter Beachtung aller nationalen Gesetze Bestimmungen erfolgen. 6. Regionale und nationale elektrische Bestimmungen t Dieses Gerät sollte unter Beachtung der regionalen und nationalen elektrischen Bestimmungen installiert werden. This equipment should be installed in compliance with local and national electrical codes. 7. Strahlenkontak Achtung Nutzung von Steuerungen oder Einstellungen oder Ausführung von Prozeduren, die hier nicht spezifiziert sind, kann zu gefährlichem Strahlenkontakt führen.. Mellanox Technologies 35 Rev 1.9 Klasse 1 Laserprodukt und Referenzen zu den aktuellsten Lasterstandards : ICE 60 825-1:1993 + A1:1997 + A2:2001 und EN 60825-1:1994+A1:1996+ A2:2001 36 Mellanox Technologies ConnectX®-3 Ethernet Single and Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project Rev 1.9 Appendix E: Advertencias de seguridad para la instalación (Warnings in Spanish) 1. Instrucciones de instalación Antes de conectar el equipo a la fuente de alimentación, leer todas las instrucciones de instalación. 2. Sobrecalentamiento No se debe utilizar el equipo en un área con una temperatura ambiente superior a la máxima recomendada: 55°C(131°F). Además, para garantizar una circulación de aire adecuada, se debe dejar como mínimo un espacio de 8 cm (3 pulgadas) alrededor de las aberturas de ventilación. 3. Cuando hay rayos: peligro de descarga eléctrica No utilizar el equipo ni conectar o desconectar cables durante períodos de actividad de rayos. 4. Instalación de equipos La instalación, el reemplazo y el mantenimiento de este equipo estarán a cargo únicamente de personal capacitado y competente. 5. Eliminación de equipos La eliminación definitiva de este equipo se debe efectuar conforme a todas las leyes y reglamentaciones nacionales. 6. Códigos eléctricos locales y nacionales Este equipo se debe instalar conforme a los códigos eléctricos locales y nacionales. 7. Exposición a niveles de radiación peligrosos Precaución: el uso de controles o ajustes o la realización de procedimientos distintos de los que aquí se especifican podrían causar exposición a niveles de radiación peligrosos. PRODUCTO LÁSER DE CLASE 1 y referencia a las normas de láser más recientes: IEC 60825-1:2007/03 y EN 60825-1:2007 Mellanox Technologies 37Acrobat Distiller 10.1.5 (Windows)