Sub-Zero International Integrated (ICB700 Base) Series Technical Data
Model ICB700BCI
FREEZER | |
CHARGE (R-134a Refrigerant) NOTE: Always check serial tag for exact charge | 0.17 Kg. |
NORMAL OPERATING PRESSURES | Low Side: 5"-1 psi to 6-15 psi High Side: 75 psi to 120 psi |
COMPRESSOR NOTE: Always check current parts price list for possible substitutions. | Original/Service Compressor Amps: ~0.65 / ~0.65 Original/Service Compressor BTU/H: 665 / 665 |
DEFROST METHOD | "Adaptive Defrost" Defrost intervals and duration vary by unit use. 5 minute compressor delay after each defrost. |
DEFROST TERMINATOR | Cut-In Temp.: -1°C / 30°F Cut-Out Temp.: 21°C / 70°F |
DEFROST HEATER | Watts: 490 Amps: 2.05 - 2.25 Resistance/Ohms: 85 - 120 |
DRAIN TUBE HEATER | Watts: 7 Mili-Amps: 25 - 35 mA Resistance/Ohms: 7800 - 8310 |
FILL TUBE HEATER | Watts: 7.2 Mili-Amps: 25 - 35 mA Resistance/Ohms: 6600 - 8100 |
WATER VALVE | Watts: 50 Amps: 0.22 Resistance/Ohms (Inductive): 950 - 1200 |
THERMISTORS (Evap & Compartment) | Resistance/Ohms at 0°C / 32°F: 30000 - 33000 |
Model ICB700BR
FREEZER | |
CHARGE (R-134a Refrigerant) NOTE: Always check serial tag for exact charge | 0.11 Kg. |
NORMAL OPERATING PRESSURES | Low Side: 0-12 psi to 30-42 psi High Side: 75 psi to 110 psi |
COMPRESSOR NOTE: Always check current parts price list for possible substitutions. | Original/Service Compressor Amps: ~0.4 / ~0.4 Original/Service Compressor BTU/H: 373 / 373 |
DEFROST METHOD | "Fan Assisted Off-Cycle Defrost" Evap > 3°C (38°F) before Compressor ON. |
THERMISTORS (Evap & Compartment) | Resistance/Ohms at 0°C / 32°F: 30000 - 33000 |
Related Documents
![]() |
Sub-Zero International Built-In ICBBI Series Technical Data Technical specifications for Sub-Zero International Built-In (ICBBI) Series refrigerators, including models ICBBI-30U, ICBBI-36F, ICBBI-36R, ICBBI-36S, ICBBI-36U, ICBBI-42S, ICBBI-42SD, ICBBI-48S, and ICBBI-48SD. |
![]() |
Sub-Zero 648PRO Refrigerator/Freezer Technical Data Technical specifications and service data for the Sub-Zero 648PRO refrigerator and freezer, including refrigerant charge, operating pressures, compressor details, defrost systems, heaters, thermistors, and door heaters. |
![]() |
Sub-Zero ICB700 Base Series Technical Service Manual - General Information This technical service manual provides comprehensive information on the Sub-Zero ICB700 Base Series appliances, including installation, setup, operation, features, troubleshooting, wiring diagrams, and repair procedures. It is intended for authorized service personnel. |
![]() |
Sub-Zero ICB Pro-Series 648PRO Technical Data Detailed technical specifications for the Sub-Zero ICB Pro-Series refrigerator model 648PRO, including refrigerant charge, operating pressures, compressor data, defrost system information, and electrical component specifications. |
![]() |
Sub-Zero ICBID-RP Integrated Drawer Refrigerator Technical Data and Error Codes Technical data and integrated refrigeration error codes for the Sub-Zero ICBID-RP Integrated Drawer Refrigerator, including airflow information, component specifications, and detailed error code explanations. |
![]() |
Sub-Zero ICB Built-In Troubleshooting Guide This comprehensive troubleshooting guide provides detailed steps and fault code explanations for the Sub-Zero ICB Built-In (ICBBI) Series refrigerators, helping users diagnose and resolve common operational issues. |
![]() |
Sub-Zero Integrated Series (Drawers) Troubleshooting Guide A comprehensive troubleshooting guide for Sub-Zero Integrated Series drawers, detailing error codes, fault descriptions, and recommended actions. Includes sealed system diagnostics and pressure tables. |
![]() |
Sub-Zero ICBBI-42UFDID Troubleshooting Guide A comprehensive troubleshooting guide for the Sub-Zero ICBBI-42UFDID built-in refrigerator, detailing fault codes, general troubleshooting steps, and component testing procedures. |