Sub-Zero International Integrated (ICB700 Base) Series Technical Data

Model ICB700BCI

FREEZER
CHARGE (R-134a Refrigerant)
NOTE: Always check serial tag for exact charge
0.17 Kg.
NORMAL OPERATING PRESSURESLow Side: 5"-1 psi to 6-15 psi
High Side: 75 psi to 120 psi
COMPRESSOR
NOTE: Always check current parts price list for possible substitutions.
Original/Service Compressor Amps: ~0.65 / ~0.65
Original/Service Compressor BTU/H: 665 / 665
DEFROST METHOD"Adaptive Defrost"
Defrost intervals and duration vary by unit use.
5 minute compressor delay after each defrost.
DEFROST TERMINATORCut-In Temp.: -1°C / 30°F
Cut-Out Temp.: 21°C / 70°F
DEFROST HEATERWatts: 490
Amps: 2.05 - 2.25
Resistance/Ohms: 85 - 120
DRAIN TUBE HEATERWatts: 7
Mili-Amps: 25 - 35 mA
Resistance/Ohms: 7800 - 8310
FILL TUBE HEATERWatts: 7.2
Mili-Amps: 25 - 35 mA
Resistance/Ohms: 6600 - 8100
WATER VALVEWatts: 50
Amps: 0.22
Resistance/Ohms (Inductive): 950 - 1200
THERMISTORS (Evap & Compartment)Resistance/Ohms at 0°C / 32°F: 30000 - 33000

Model ICB700BR

FREEZER
CHARGE (R-134a Refrigerant)
NOTE: Always check serial tag for exact charge
0.11 Kg.
NORMAL OPERATING PRESSURESLow Side: 0-12 psi to 30-42 psi
High Side: 75 psi to 110 psi
COMPRESSOR
NOTE: Always check current parts price list for possible substitutions.
Original/Service Compressor Amps: ~0.4 / ~0.4
Original/Service Compressor BTU/H: 373 / 373
DEFROST METHOD"Fan Assisted Off-Cycle Defrost"
Evap > 3°C (38°F) before Compressor ON.
THERMISTORS (Evap & Compartment)Resistance/Ohms at 0°C / 32°F: 30000 - 33000

Models: ICB700BR, ICB700BFI, ICB700BCI International Integrated Freezer, ICB700BCI, International Integrated Freezer, Integrated Freezer, Freezer