User Guide for intertek models including: UBS-879120 Square Base Stand Weight for Patio Market Table Umbrella Outdoor Bronze, UBS-879120, Square Base Stand Weight for Patio Market Table Umbrella Outdoor Bronze, Patio Market Table Umbrella Outdoor Bronze, Umbrella Outdoor Bronze, Outdoor Bronze
FLAME&SHADE 26lb Square Base Stand Weight for Patio Market Table Umbrella Outdoor, Bronze : Patio, Lawn & Garden
File Info : application/pdf, 11 Pages, 237.64KB
DocumentDocumentTest Report Applicant LINHAI TAIJI CRAFTS CO., LTD. NO 7, DONGGANG MIDDLE ROAD, DAYANG STREET, LINHAI CITY, ZHEJIANG PROVINCE, CHINA Attn MELINDA Number SHAH01604122 Date 20 Sep, 2023 Sample Description One (1) group of submitted sample said to be Item Name RR RD RESIN UMB BASE 17.5" 26.4 LBS Item No. UBS-879120 Quantity 1pc Goods Exported To USA Country Of Origin China ******************************************************************************************************************************************************* Tests Conducted As requested by the applicant, for details refer to attached page(s). ******************************************************************************************************************************************************* Conclusion: The submitted samples conformed to MPS test protocol for Umbrella Base (Version: 2) Test Property Chemical Test Physical Properties Construction & Workmanship Performance Test Labeling Requirement Rating Pass Fail X X X X Remarks / Comments Not applicable Meet Federal Regulation ( X) Fail Federal Regulation ( ) Meets ITS Performance Std ( X ) Fails ITS Performance Std ( ) ****************************************************************************************************************************************************** Comments:Nil Remarks: #1 No artwork of packaging and label were provided for review. ****************************************************************************************************************************************************** To be continued Authorized By Intertek Testing Services Ltd. Zhejiang Bobo Yao Assistant General Manager INTERTEK TESTING SERVICES LTD. ZHEJIANG Page 1 of 11 Building No.2, Juanhu Science and Technology Innovation Park, No. 500 East Shuiyueting Road, Haining City, Zhejiang Province,China. 314400 500 2 314400 Tel: +86 573 87137200 Zip:314400 www.intertek.com www.intertek.com.cn Test Report Number SHAH01604122 Conclusion: Tested samples Standard Result Submitted carton of packaged product ISTA test procedure 1A: 2014 Pass ***************************************************************************************************************************************************** To be continued Authorized By Intertek Testing Services Ltd. Zhejiang Bobo Yao Assistant General Manager INTERTEK TESTING SERVICES LTD. ZHEJIANG Page 2 of 11 Building No.2, Juanhu Science and Technology Innovation Park, No. 500 East Shuiyueting Road, Haining City, Zhejiang Province,China. 314400 500 2 314400 Tel: +86 573 87137200 Zip:314400 www.intertek.com www.intertek.com.cn Test Report Tests Conducted Number SHAH01604122 1.As requested by the applicant, the submitted sample was tested as per MPS-03087-US Dated Apr 26, 2022, the test results were listed as below: Test Description Chemical Test * Lead Content in Paint or Similar Surface Coating * Toxic Elements in Packaging Components Test Method Requirement With reference to 16 CFR 1303 Various US State Laws / TPCH Shall not contain Lead or Lead compounds in which the Lead content is in excess of 0.009% (90ppm) by weight of the total content. Packaging shall comply with TPCH in those states with legislation. Total concentration of Pb, Cd, Hg and hexavalent Cr shall not exceed100 ppm. Result Meet NA Rating P - In lieu of testing, test report or guarantee letter can be submitted if dated within 1 year. * Phthalates in TPCH and its 2021 The sum of phthalates in package or packaging NA - Packaging Update component shall not exceed 100 ppm. Components In lieu of testing, test report or guarantee letter can be submitted if dated within 1 year. * PFAS in TPCH and its 2021 There shall be no detectable PFAS in package or NA - Packaging Update packaging component. Components In lieu of testing, test report or guarantee letter can be submitted if dated within 1 year. * EPA TSCA Title 40 CFR 770 / Client If regulated composite wood is not present in the NA - VI Composite Requirement sample, result is N/A. Wood If regulated composite wood is present in the sample: - Vendors shall provide completed ITS's Certificate of Compliance (COC) for TSCA Formaldehyde Emission Standard which certify that the finished product containing composite wood (defined by 40 CFR 770) are compliant with the TSCA formaldehyde emission standards, rules and regulations. Physical Properties Overall Dimensions ITS-M0059 Note: Regulated composite wood includes: - Hardwood plywood (HWPW) - Medium-density fiberboard (MDF) - Thin medium-density fiberboard (Thin MDF) - Particleboard (PB) Rating Schedule: - On or after June 1, 2018: Compliant submission shall be rated as pass. Noncompliant submission shall be rated as fail. Report actual. Shall meet label claims (If applicable). R: - 17.3in.x12.8in.(H) No claims INTERTEK TESTING SERVICES LTD. ZHEJIANG Page 3 of 11 Building No.2, Juanhu Science and Technology Innovation Park, No. 500 East Shuiyueting Road, Haining City, Zhejiang Province,China. 314400 500 2 314400 Tel: +86 573 87137200 Zip:314400 www.intertek.com www.intertek.com.cn Test Report Number SHAH01604122 Tests Conducted Test Description Overall Weight Test Method ITS-M0059 Requirement Report actual. Shall meet label claims (If applicable). Result R: 26.73lb. Rating - No claims Pole Holder Inner ITS-M0059 Report actual. Shall meet label claims (If R: - Diameter applicable). 1.58in. No claims Depth of Pole ITS-M0059 Report actual. Shall meet label claims (If R: - Insert applicable). 9in. Pitch of Pole Insert Material Type ITS-M0059 Visual Check The axis of the insert slot of umbrella base shall not deviate be more than 2° from the vertical axis. Report actual. Shall meet label claims (If applicable). No claims Meet P R: - Cement,Metal,Plastic No claims Construction & Workmanship Sharp Points / With reference to 16 Shall have no sharp points or edges as received, Meet P Edges CFR other than those required for function. 1500.48 / 1500.49 Workmanship Visual Check Shall have no discernible surface degradation, Meet P including but not limited to crazing, shivering, denting, bubbles, cracks, stains, deformations, chips, fractures, heavy lines, waves, shear marks, scratches, scuff marks, indentations, or blisters. Components Visual Check Shall have no components missing, malformed, Meet P and/or fractured. Weld / Glue Visual Check Shall be smoothly ground and free from pits and Meet P splatter. Performance Test Functionality ITS-M0061 Shall function as intended as received. Meet P Assembly ITS-M0068 Shall be assembled as instructed or intended Meet P without any adverse findings obstructing assembly. Pole Securement In-house Method For umbrella base: Meet P - Shall tighten easily to hold umbrella securely in (No labeled, upright position. Maximum test: - Shall be adjustable to accommodate the minimum 1.48in.) and maximum labeled pole sizes. Report minimum and maximum pole sizes tested. * Stability with ITS-M0015 There shall not tip over after inserting the testing Umbrella Inserted umbrella in umbrella base on a horizontal floor. When a tilt-type umbrella is installed as intended Meet and tilted to a position most likely to cause tip-over. (Test with 9ft Then repeat the test at 8° incline surface. Record umbrella: umbrella height, weight, pole diameter and testing Height: 92.5 in. P position (such as testing height or tilt angle if Weight: 4.35kg applicable). Pole diameter: 1.48 in.) NOTE: Only perform the test when testing umbrella is provided by vendor for testing. INTERTEK TESTING SERVICES LTD. ZHEJIANG Page 4 of 11 Building No.2, Juanhu Science and Technology Innovation Park, No. 500 East Shuiyueting Road, Haining City, Zhejiang Province,China. 314400 500 2 314400 Tel: +86 573 87137200 Zip:314400 www.intertek.com www.intertek.com.cn Test Report Number SHAH01604122 Tests Conducted Test Description * Leakage (For umbrella base intended to be filled) * Cross Cut Test Test Method ITS-M0061 EN ISO 2409 * Cyclic Test (For operable component) * Effects of Extreme Temperature ITS-M0061 ITS-M0007 * Moisture Content (For solid wood) * Resistance to Corrosion (For metal components) * Transit Testing (By request only) ITS-M0054 ASTM B117 ISTA Procedure as Appropriate to Package Labeling Requirement Requirement Umbrella base shall have no leakage when filled with the intended material (such as water or sand) of claimed capacity for 24 hours. For coating on metal component: Classification 2 min. Operable component shall withstand 100 times actual use cycles without failure or loss of functionality. Shall withstand for 24 hours at 0 degrees Fahrenheit and then 24 hours at 120 degrees Fahrenheit with no structural failure or visual change. Moisture content of solid wood shall be within 8% 12%. Metal components shall withstand 24 hours in 5% salt spray (fog) with no major corrosion or visual change. Packaged product shall be tested to applicable ISTA procedure and method, based on package configuration. Inspect package and product for damage upon completion of test. Report results. Result NA (No filled) Meet NA Meet NA Meet Meet Rating - P P P P INTERTEK TESTING SERVICES LTD. ZHEJIANG Page 5 of 11 Building No.2, Juanhu Science and Technology Innovation Park, No. 500 East Shuiyueting Road, Haining City, Zhejiang Province,China. 314400 500 2 314400 Tel: +86 573 87137200 Zip:314400 www.intertek.com www.intertek.com.cn Test Report Number SHAH01604122 Tests Conducted Test Description * EPA TSCA Title VI Composite Wood - Finished Good Labeling Test Method 40 CFR 770.45(c) / 40 CFR 770.45(e) Requirement Finished goods containing regulated composite wood shall comply with the labeling requirements found in 40 CFR 770.45(c) unless the finished good qualifies for the de minimis exception found in 40 CFR 770.45(e). Result NA A finished good does not require labeling per 40 CFR 770.45(c) if the finished good does qualify for the de minimis exception in 40 CFR 770.45(e). If the finished good does qualify for the de minimis exception, result is N/A. A finished good does require labeling per 40 CFR 770.45(c) if the finished good does not qualify for the de minimis exeption in 40 CFR 770.45(e). - At a minimum, the label must be on the product OR the packaging - The label may be applied as a stamp, tag, or sticker - The label shall include, at a minimum, in legible English text: 1. Fabricator's name 2. Date the finished good was produced (in month/year format) 3. A statement of compliance to denote that the finished good complies with TSCA Title VI Example: XXX Company MM/YYYY TSCA Title VI compliant for formaldehyde Notes: A de minimis amount of regulated composite wood is defined as regulated composite wood content not exceeding 144 square inches, based on the surface area of the largest face of the finished good. The de minimis exception is not available to finished goods or component parts that are designed to be used in combination or in multiples to create larger surfaces, finished goods, or component parts. Rating Schedule: - On or after June 1, 2018*: Compliant submission shall be rated as pass. Non- compliant submission shall be rated as fail. *Products labeled as CARB acceptable until March 21, 2019. *On or after March 22nd, only TSCA label acceptable. Rating - IMPORTANT NOTE: The information presented under the "Requirements / Limits" column of this protocol is for information only and does not replace the content of the standard. Details of the requirements should be referred to the original standards. INTERTEK TESTING SERVICES LTD. ZHEJIANG Page 6 of 11 Building No.2, Juanhu Science and Technology Innovation Park, No. 500 East Shuiyueting Road, Haining City, Zhejiang Province,China. 314400 500 2 314400 Tel: +86 573 87137200 Zip:314400 www.intertek.com www.intertek.com.cn Test Report Number Tests Conducted REMARK: Additional tests may be incurred subject to the final samples reviewed by Intertek. KEY: : Mandatory Requirement * : Additional charge items Results Key: NA Not Applicable NR Not Requested C Claimed F Fail NT Not Tested R Recorded P Pass Date of Sample Received: Aug 30,2023 Testing Period: Aug 30,2023 to Sep 19,2023 SHAH01604122 2.TRANSPORTATION TEST (ISTA 1A) As per ISTA integrity test procedure 1A: 2014, the performance and integrity of the packaged product was evaluated. Number of sample tested: One (1) carton 1. Shipping mark: Nil 2. Description of package: External container size (inch) : Length _21.75_ x width _18.75_ x depth _3.5_ Gross weight (lbs) : 28.49 Box style : Full overlap slotted container (FOL) Wall Corrugated board : Double Box maker's certificate : No Joint : Glued joint Closed with : Pressure-sensitive tape Style (See enclosed picture 1) : Top opening. 3. Test procedure (a) Atmospheric preconditioning Laboratory ambient temperature and humidity for twelve (12) hours at: _22.5_ °C, _55_ % RH. (b) Vibration test Mode of vibration: (b1)Before a single 90°horizontal rotation Vibration frequency: (CPM) Rotary _200_ cycles per minute Duration of testing: _35_ Minutes and _30_ seconds INTERTEK TESTING SERVICES LTD. ZHEJIANG Page 7 of 11 Building No.2, Juanhu Science and Technology Innovation Park, No. 500 East Shuiyueting Road, Haining City, Zhejiang Province,China. 314400 500 2 314400 Tel: +86 573 87137200 Zip:314400 www.intertek.com www.intertek.com.cn Test Report Tests Conducted Number of Vibration:(Cycles) 7,100 (b2)After a single 90°horizontal rotation Vibration frequency: (CPM) _200_ cycles per minute Duration of testing: _35_ Minutes and _30_ seconds Number of Vibration:(Cycles) 7,100 Remark: No puncture of carton box was observed. (c) Drop test Method used: Free fall drop Number of drops: 10 Height of drop (inches): 24 1). No puncture of carton box was observed. 2). The test drop height varies with the weight of the packaged-product. The drop height and the weight were listed as below: Packaged-product weight (lb) 0 G <21lb 21 G <41 lb 41 G <61 lb 61 G <100 lb. 100 G <150 lb. Number SHAH01604122 Drop height (in.) 30 24 18 12 8 3). The drop sequence and orientation were listed as below: Sequence Orientation Specific face edge or corner 1 Corner Most fragile face-3 corner, if not known, test 2-3-5 2 Edge Shortest edge radiating from the corner tested 3 Edge Next longest edge radiating from the corner tested 4 Edge Longest edge radiating from the corner tested 5 Face One of the smallest face 6 Face Opposite small face 7 Face One of the medium face 8 Face Opposite medium face 9 Face One of the largest face 10 Face Opposite large face Verify face edge or corner 4. Interior packaging: See enclosed pictures INTERTEK TESTING SERVICES LTD. ZHEJIANG Page 8 of 11 Building No.2, Juanhu Science and Technology Innovation Park, No. 500 East Shuiyueting Road, Haining City, Zhejiang Province,China. 314400 500 2 314400 Tel: +86 573 87137200 Zip:314400 www.intertek.com www.intertek.com.cn Test Report Number SHAH01604122 Tests Conducted Result: Neither visible damage nor malfunction was observed on the contents of the packaged product. Date Sample Received: Aug 22, 2023 Testing Period: Aug 22, 2023 to Aug 25, 2023 3.Total Lead (Pb) Content As per U.S. Code of Federal Regulations title 16 part 1303, acid digestion method was used and total Lead content was determined by Inductively Coupled Argon Plasma Spectrometry. Tested component (1) Result (%) ND Limit (%) 0.009 The limit was quoted according to CPSC Regulation CFR title 16 Part 1303 for Lead (Pb) content. RemarkND = Not Detected Detection Limit = 0.002% Tested ComponentsSee component list in the last section of this report. Date Sample Received: Aug 22, 2023 Testing Period: Aug 22, 2023 to Sep 14, 2023 Tested components: (1) Black coating on metal Picture 1: Submitted sample Picture 2: Submitted Sample INTERTEK TESTING SERVICES LTD. ZHEJIANG Page 9 of 11 Building No.2, Juanhu Science and Technology Innovation Park, No. 500 East Shuiyueting Road, Haining City, Zhejiang Province,China. 314400 500 2 314400 Tel: +86 573 87137200 Zip:314400 www.intertek.com www.intertek.com.cn Test Report Tests Conducted Number SHAH01604122 Picture 3:_Exhibit Picture 4:_Exhibit Picture 5:_Exhibit Picture 6:_Exhibit Picture 7:_Exhibit Picture 8:_Exhibit INTERTEK TESTING SERVICES LTD. ZHEJIANG Page 10 of 11 Building No.2, Juanhu Science and Technology Innovation Park, No. 500 East Shuiyueting Road, Haining City, Zhejiang Province,China. 314400 500 2 314400 Tel: +86 573 87137200 Zip:314400 www.intertek.com www.intertek.com.cn Test Report Tests Conducted Number SHAH01604122 Picture 9:_Exhibit Picture 10:_Exhibit ********************************************************************************************************************************************** End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. This report shall not be reproduced except in full, without written approval of the laboratory. INTERTEK TESTING SERVICES LTD. ZHEJIANG Page 11 of 11 Building No.2, Juanhu Science and Technology Innovation Park, No. 500 East Shuiyueting Road, Haining City, Zhejiang Province,China. 314400 500 2 314400 Tel: +86 573 87137200 Zip:314400 www.intertek.com www.intertek.com.cn