User Guide for intertek models including: UBS-879120 Square Base Stand Weight for Patio Market Table Umbrella Outdoor Bronze, UBS-879120, Square Base Stand Weight for Patio Market Table Umbrella Outdoor Bronze, Patio Market Table Umbrella Outdoor Bronze, Umbrella Outdoor Bronze, Outdoor Bronze

its9375

necadmmars

Certificate of Compliance (PDF)

FLAME&SHADE 26lb Square Base Stand Weight for Patio Market Table Umbrella Outdoor, Bronze : Patio, Lawn & Garden


File Info : application/pdf, 11 Pages, 237.64KB

PDF preview unavailable. Download the PDF instead.

715aG2qgGeL
Test Report

Applicant

LINHAI TAIJI CRAFTS CO., LTD. NO 7, DONGGANG MIDDLE ROAD, DAYANG STREET, LINHAI CITY, ZHEJIANG PROVINCE, CHINA
Attn MELINDA

Number SHAH01604122 Date 20 Sep, 2023

Sample Description

One (1) group of submitted sample said to be 

Item Name

 RR RD RESIN UMB BASE 17.5" 26.4 LBS

Item No.

 UBS-879120

Quantity

 1pc

Goods Exported To

 USA

Country Of Origin

 China

******************************************************************************************************************************************************* Tests Conducted

As requested by the applicant, for details refer to attached page(s).

******************************************************************************************************************************************************* Conclusion:

The submitted samples conformed to MPS test protocol for Umbrella Base (Version: 2)

Test Property
Chemical Test Physical Properties Construction & Workmanship Performance Test Labeling Requirement

Rating

Pass

Fail

X

X

X

X

Remarks / Comments Not applicable

Meet Federal Regulation

( X)

Fail Federal Regulation

( )

Meets ITS Performance Std ( X )

Fails ITS Performance Std ( )

******************************************************************************************************************************************************

Comments:Nil

Remarks:

#1 No artwork of packaging and label were provided for review.

******************************************************************************************************************************************************

To be continued

Authorized By Intertek Testing Services Ltd. Zhejiang

Bobo Yao Assistant General Manager
INTERTEK TESTING SERVICES LTD. ZHEJIANG 

Page 1 of 11

Building No.2, Juanhu Science and Technology Innovation Park, No. 500 East Shuiyueting Road, Haining City, Zhejiang Province,China. 314400  500   2  314400

Tel: +86 573 87137200 Zip:314400 www.intertek.com www.intertek.com.cn

Test Report

Number SHAH01604122

Conclusion:

Tested samples

Standard

Result

Submitted carton of packaged product

ISTA test procedure 1A: 2014

Pass

*****************************************************************************************************************************************************

To be continued

Authorized By Intertek Testing Services Ltd. Zhejiang

Bobo Yao Assistant General Manager
INTERTEK TESTING SERVICES LTD. ZHEJIANG 

Page 2 of 11

Building No.2, Juanhu Science and Technology Innovation Park, No. 500 East Shuiyueting Road, Haining City, Zhejiang Province,China. 314400  500   2  314400

Tel: +86 573 87137200 Zip:314400 www.intertek.com www.intertek.com.cn

Test Report Tests Conducted

Number SHAH01604122

1.As requested by the applicant, the submitted sample was tested as per MPS-03087-US Dated Apr 26, 2022, the test results were listed as below:

Test Description
Chemical Test
* Lead Content in Paint or Similar Surface Coating
* Toxic Elements in Packaging Components

Test Method

Requirement

With reference to 16 CFR 1303
Various US State Laws / TPCH

Shall not contain Lead or Lead compounds in which the Lead content is in excess of 0.009% (90ppm) by weight of the total content.
Packaging shall comply with TPCH in those states with legislation. Total concentration of Pb, Cd, Hg and hexavalent Cr shall not exceed100 ppm.

Result Meet
NA

Rating P
-

In lieu of testing, test report or guarantee letter can

be submitted if dated within 1 year.

* Phthalates in

TPCH and its 2021 The sum of phthalates in package or packaging

NA

-

Packaging

Update

component shall not exceed 100 ppm.

Components

In lieu of testing, test report or guarantee letter can

be submitted if dated within 1 year.

* PFAS in

TPCH and its 2021 There shall be no detectable PFAS in package or NA

-

Packaging

Update

packaging component.

Components

In lieu of testing, test report or guarantee letter can

be submitted if dated within 1 year.

* EPA TSCA Title 40 CFR 770 / Client  If regulated composite wood is not present in the NA

-

VI ­ Composite

Requirement

sample, result is N/A.

Wood

 If regulated composite wood is present in the

sample:

- Vendors shall provide completed ITS's Certificate

of Compliance (COC) for TSCA Formaldehyde

Emission Standard which certify that the finished

product containing composite wood (defined by 40

CFR 770) are compliant with the TSCA

formaldehyde emission standards, rules and

regulations.

Physical Properties Overall Dimensions

ITS-M0059

Note:  Regulated composite wood includes: - Hardwood plywood (HWPW) - Medium-density fiberboard (MDF) - Thin medium-density fiberboard (Thin MDF)
- Particleboard (PB)  Rating Schedule: - On or after June 1, 2018:
Compliant submission shall be rated as pass. Noncompliant submission shall be rated as fail.

Report actual. Shall meet label claims (If applicable).

R:

-

17.3in.x12.8in.(H)

No claims

INTERTEK TESTING SERVICES LTD. ZHEJIANG 

Page 3 of 11

Building No.2, Juanhu Science and Technology Innovation Park, No. 500 East Shuiyueting Road, Haining City, Zhejiang Province,China. 314400  500   2  314400

Tel: +86 573 87137200 Zip:314400 www.intertek.com www.intertek.com.cn

Test Report

Number SHAH01604122

Tests Conducted Test Description Overall Weight

Test Method ITS-M0059

Requirement Report actual. Shall meet label claims (If applicable).

Result R: 26.73lb.

Rating -

No claims

Pole Holder Inner

ITS-M0059

Report actual. Shall meet label claims (If

R:

-

Diameter

applicable).

1.58in.

No claims

Depth of Pole

ITS-M0059

Report actual. Shall meet label claims (If

R:

-

Insert

applicable).

9in.

Pitch of Pole Insert Material Type

ITS-M0059 Visual Check

The axis of the insert slot of umbrella base shall not deviate be more than 2° from the vertical axis.
Report actual. Shall meet label claims (If applicable).

No claims

Meet

P

R:

-

Cement,Metal,Plastic

No claims

Construction & Workmanship

Sharp Points /

With reference to 16 Shall have no sharp points or edges as received, Meet

P

Edges

CFR

other than those required for function.

1500.48 / 1500.49

Workmanship

Visual Check

Shall have no discernible surface degradation,

Meet

P

including but not limited to crazing, shivering,

denting, bubbles, cracks, stains, deformations,

chips, fractures, heavy lines, waves, shear marks,

scratches, scuff marks, indentations, or blisters.

Components

Visual Check

Shall have no components missing, malformed,

Meet

P

and/or fractured.

Weld / Glue

Visual Check

Shall be smoothly ground and free from pits and Meet

P

splatter.

Performance Test

Functionality

ITS-M0061

Shall function as intended as received.

Meet

P

Assembly

ITS-M0068

Shall be assembled as instructed or intended

Meet

P

without any adverse findings obstructing assembly.

Pole Securement

In-house Method For umbrella base:

Meet

P

- Shall tighten easily to hold umbrella securely in (No labeled,

upright position.

Maximum test:

- Shall be adjustable to accommodate the minimum 1.48in.) and maximum labeled pole sizes.

Report minimum and maximum pole sizes tested.

* Stability with

ITS-M0015

There shall not tip over after inserting the testing

Umbrella Inserted

umbrella in umbrella base on a horizontal floor.

When a tilt-type umbrella is installed as intended

Meet

and tilted to a position most likely to cause tip-over. (Test with 9ft

Then repeat the test at 8° incline surface. Record umbrella:

umbrella height, weight, pole diameter and testing Height: 92.5 in.

P

position (such as testing height or tilt angle if

Weight: 4.35kg

applicable).

Pole diameter:

1.48 in.)

NOTE: Only perform the test when testing umbrella

is provided by vendor for testing.

INTERTEK TESTING SERVICES LTD. ZHEJIANG 

Page 4 of 11

Building No.2, Juanhu Science and Technology Innovation Park, No. 500 East Shuiyueting Road, Haining City, Zhejiang Province,China. 314400  500   2  314400

Tel: +86 573 87137200 Zip:314400 www.intertek.com www.intertek.com.cn

Test Report

Number SHAH01604122

Tests Conducted
Test Description * Leakage (For umbrella base intended to be filled) * Cross Cut Test

Test Method ITS-M0061
EN ISO 2409

* Cyclic Test (For operable component)
* Effects of Extreme Temperature

ITS-M0061 ITS-M0007

* Moisture Content (For solid wood)
* Resistance to Corrosion (For metal components)
* Transit Testing (By request only)

ITS-M0054 ASTM B117
ISTA Procedure as Appropriate to Package

Labeling Requirement

Requirement Umbrella base shall have no leakage when filled with the intended material (such as water or sand) of claimed capacity for 24 hours.
For coating on metal component: Classification 2 min. Operable component shall withstand 100 times actual use cycles without failure or loss of functionality. Shall withstand for 24 hours at 0 degrees Fahrenheit and then 24 hours at 120 degrees Fahrenheit with no structural failure or visual change. Moisture content of solid wood shall be within 8% 12%. Metal components shall withstand 24 hours in 5% salt spray (fog) with no major corrosion or visual change.
Packaged product shall be tested to applicable ISTA procedure and method, based on package configuration. Inspect package and product for damage upon completion of test. Report results.

Result NA (No filled)
Meet NA
Meet
NA Meet
Meet

Rating -
P P
P
P

INTERTEK TESTING SERVICES LTD. ZHEJIANG 

Page 5 of 11

Building No.2, Juanhu Science and Technology Innovation Park, No. 500 East Shuiyueting Road, Haining City, Zhejiang Province,China. 314400  500   2  314400

Tel: +86 573 87137200 Zip:314400 www.intertek.com www.intertek.com.cn

Test Report

Number SHAH01604122

Tests Conducted
Test Description * EPA TSCA Title VI ­ Composite Wood - Finished Good Labeling

Test Method 40 CFR 770.45(c) /
40 CFR 770.45(e)

Requirement
Finished goods containing regulated composite wood shall comply with the labeling requirements found in 40 CFR 770.45(c) unless the finished good qualifies for the de minimis exception found in 40 CFR 770.45(e).

Result NA

 A finished good does not require labeling per 40 CFR 770.45(c) if the finished good does qualify for the de minimis exception in 40 CFR 770.45(e). If the finished good does qualify for the de minimis
exception, result is N/A.

 A finished good does require labeling per 40 CFR 770.45(c) if the finished good does not qualify for the de minimis exeption in 40 CFR 770.45(e). - At a minimum, the label must be on the product OR the packaging - The label may be applied as a stamp, tag, or sticker - The label shall include, at a minimum, in legible English text: 1. Fabricator's name 2. Date the finished good was produced (in month/year format) 3. A statement of compliance to denote that the finished good complies with TSCA Title VI

Example: XXX Company MM/YYYY TSCA Title VI compliant for formaldehyde

Notes:  A de minimis amount of regulated composite wood is defined as regulated composite wood content not exceeding 144 square inches, based on the surface area of the largest face of the
finished good.  The de minimis exception is not available to finished goods or component parts that are
designed to be used in combination or in multiples to create larger surfaces, finished goods, or component parts.  Rating Schedule: - On or after June 1, 2018*: Compliant submission shall be rated as pass. Non-
compliant submission shall be rated as fail.

*Products labeled as CARB acceptable until March 21, 2019. *On or after March 22nd, only TSCA label acceptable.

Rating -

IMPORTANT NOTE: The information presented under the "Requirements / Limits" column of this protocol is for information only and does not replace the content of the standard. Details of the requirements should be referred to the original standards.

INTERTEK TESTING SERVICES LTD. ZHEJIANG 

Page 6 of 11

Building No.2, Juanhu Science and Technology Innovation Park, No. 500 East Shuiyueting Road, Haining City, Zhejiang Province,China. 314400  500   2  314400

Tel: +86 573 87137200 Zip:314400 www.intertek.com www.intertek.com.cn

Test Report

Number

Tests Conducted REMARK: Additional tests may be incurred subject to the final samples reviewed by Intertek.

KEY:  : Mandatory Requirement

* : Additional charge items

Results Key: NA Not Applicable NR Not Requested C Claimed F Fail

NT Not Tested

R

Recorded

P

Pass

Date of Sample Received: Aug 30,2023 Testing Period: Aug 30,2023 to Sep 19,2023

SHAH01604122

2.TRANSPORTATION TEST (ISTA 1A)

As per ISTA integrity test procedure 1A: 2014, the performance and integrity of the packaged product was evaluated.

Number of sample tested: One (1) carton

1. Shipping mark: Nil

2. Description of package:

External container size (inch)

: Length _21.75_ x width _18.75_ x depth _3.5_

Gross weight (lbs)

: 28.49

Box style

: Full overlap slotted container (FOL)

Wall Corrugated board

: Double

Box maker's certificate

: No

Joint

: Glued joint

Closed with

: Pressure-sensitive tape

Style (See enclosed picture 1)

: Top opening.

3. Test procedure

(a) Atmospheric preconditioning

Laboratory ambient temperature and humidity for twelve (12) hours at: _22.5_ °C, _55_ % RH.

(b) Vibration test

Mode of vibration: (b1)Before a single 90°horizontal rotation
Vibration frequency: (CPM)

Rotary _200_ cycles per minute

Duration of testing:

_35_ Minutes and _30_ seconds

INTERTEK TESTING SERVICES LTD. ZHEJIANG 

Page 7 of 11

Building No.2, Juanhu Science and Technology Innovation Park, No. 500 East Shuiyueting Road, Haining City, Zhejiang Province,China. 314400  500   2  314400

Tel: +86 573 87137200 Zip:314400 www.intertek.com www.intertek.com.cn

Test Report

Tests Conducted Number of Vibration:(Cycles)

7,100

(b2)After a single 90°horizontal rotation Vibration frequency: (CPM)

_200_ cycles per minute

Duration of testing:

_35_ Minutes and _30_ seconds

Number of Vibration:(Cycles)

7,100

Remark: No puncture of carton box was observed.

(c) Drop test

Method used:

Free fall drop

Number of drops:

10

Height of drop (inches):

24

1). No puncture of carton box was observed. 2). The test drop height varies with the weight of the packaged-product.

The drop height and the weight were listed as below: Packaged-product weight (lb) 0 G <21lb
21 G <41 lb
41 G <61 lb 61 G <100 lb.
100 G <150 lb.

Number SHAH01604122
Drop height (in.) 30 24 18 12 8

3). The drop sequence and orientation were listed as below:

Sequence

Orientation Specific face edge or corner

1

Corner

Most fragile face-3 corner, if not known, test 2-3-5

2

Edge

Shortest edge radiating from the corner tested

3

Edge

Next longest edge radiating from the corner tested

4

Edge

Longest edge radiating from the corner tested

5

Face

One of the smallest face

6

Face

Opposite small face

7

Face

One of the medium face

8

Face

Opposite medium face

9

Face

One of the largest face

10

Face

Opposite large face

Verify face edge or corner

4. Interior packaging: See enclosed pictures

INTERTEK TESTING SERVICES LTD. ZHEJIANG 

Page 8 of 11

Building No.2, Juanhu Science and Technology Innovation Park, No. 500 East Shuiyueting Road, Haining City, Zhejiang Province,China. 314400  500   2  314400

Tel: +86 573 87137200 Zip:314400 www.intertek.com www.intertek.com.cn

Test Report

Number SHAH01604122

Tests Conducted Result: Neither visible damage nor malfunction was observed on the contents of the packaged product.

Date Sample Received: Aug 22, 2023 Testing Period: Aug 22, 2023 to Aug 25, 2023

3.Total Lead (Pb) Content

As per U.S. Code of Federal Regulations title 16 part 1303, acid digestion method was used and total Lead content was determined by Inductively Coupled Argon Plasma Spectrometry.

Tested component (1)

Result (%) ND

Limit (%) 0.009

The limit was quoted according to CPSC Regulation CFR title 16 Part 1303 for Lead (Pb) content.

RemarkND = Not Detected Detection Limit = 0.002%

Tested ComponentsSee component list in the last section of this report.

Date Sample Received: Aug 22, 2023 Testing Period: Aug 22, 2023 to Sep 14, 2023

Tested components: (1) Black coating on metal

Picture 1: Submitted sample

Picture 2: Submitted Sample

INTERTEK TESTING SERVICES LTD. ZHEJIANG 

Page 9 of 11

Building No.2, Juanhu Science and Technology Innovation Park, No. 500 East Shuiyueting Road, Haining City, Zhejiang Province,China. 314400  500   2  314400

Tel: +86 573 87137200 Zip:314400 www.intertek.com www.intertek.com.cn

Test Report Tests Conducted

Number SHAH01604122

Picture 3:_Exhibit

Picture 4:_Exhibit

Picture 5:_Exhibit

Picture 6:_Exhibit

Picture 7:_Exhibit

Picture 8:_Exhibit

INTERTEK TESTING SERVICES LTD. ZHEJIANG 

Page 10 of 11

Building No.2, Juanhu Science and Technology Innovation Park, No. 500 East Shuiyueting Road, Haining City, Zhejiang Province,China. 314400  500   2  314400

Tel: +86 573 87137200 Zip:314400 www.intertek.com www.intertek.com.cn

Test Report Tests Conducted

Number SHAH01604122

Picture 9:_Exhibit

Picture 10:_Exhibit

********************************************************************************************************************************************** End of Report

This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct.
This report shall not be reproduced except in full, without written approval of the laboratory.

INTERTEK TESTING SERVICES LTD. ZHEJIANG 

Page 11 of 11

Building No.2, Juanhu Science and Technology Innovation Park, No. 500 East Shuiyueting Road, Haining City, Zhejiang Province,China. 314400  500   2  314400

Tel: +86 573 87137200 Zip:314400 www.intertek.com www.intertek.com.cn



References

Acrobat Distiller 7.0 (Windows)