Congratulations on purchasing a new Sentinel Dehumidifier. Your new dehumidifier comes with an extensive warranty plan. To register, simply fill out and return the warranty form provided in your dehumidifier box.

Be sure to note your dehumidifier serial number as you will need it for registration.

Safety Notes

Identification

For future reference, write down the model, serial number, and date of purchase for your dehumidifier. This is extremely helpful if you need to seek assistance in the future. The data label on the side of your unit has the key characteristics of your specific unit.

Model Number: Sentinel HDi90

Serial Number: _________________________

Date of Purchase: _________________________

For additional questions concerning your dehumidifier, the following options are available:

Electrical Supply

Power Supply: 115 V, 60 Hz AC, Single Phase

Outlet Requirement: 3-Prong, GFCI

Circuit Protector: 15 Amp

WARNING: 240 Volts AC may cause serious injury from electric shock.

To reduce risk of injury:

  1. Disconnect electrical power before servicing.
  2. Only plug unit into grounded electrical circuit.
  3. Do not use an extension cord.
  4. Do not use a plug adapter.

Principle of Operation

The Sentinel Series Dehumidifiers utilize its integral humidistat to monitor the conditioned space. When the relative humidity goes above the selected set point, the dehumidifier will energize. Air is drawn across an evaporator coil, which is cooler than the dew point of air. This means moisture will condense out of the air. The air is then reheated through the condenser coil and distributed back into the room.

Installation

The area to be controlled should be sealed with a vapor barrier. If unit is installed in a crawlspace, all vents should be sealed.

WARNING: Do not install your dehumidifier in a corrosive environment. Some liquid vapor barriers dry via "solvent evaporation". Always make sure that barrier is completely dry and area is throughly ventilated before installing dehumidifier.

Step #1: Place dehumidifier on a level surface.

Do not place unit directly on vapor barrier. For example, use blocks or pavers to create a level surface.

If the unit is handled in such a manner that the compressor did not remain in the upright position, you will need to place it on a level surface, then wait a minimum of 2 hours before turning "on".

Step #2: Set Up Drain Line

The included drain line attaches to unit via a compression type fitting on the discharge end of the unit. To attach drain line, remove the compression nut and slide it over the end of the hose to be attached to unit. Slide compression nut side of hose over the insert on the compression fitting completely. Tighten compression nut.

Step #3: Plug unit into 15 amp grounded circuit.

Key Functions

Control panel diagram: Features Power (?), Up (▲), Down (▼), Mode (M), Temperature (T), Continuous (C), and Drain Pump (P) buttons. Includes indicators for Compressor, Defrost, and Drain. A digital display shows humidity.

1. Power Key ?

Use this button to turn the dehumidifier on and off. Press once to turn the machine on. You will hear 1 beep and the light will illuminate green. Press the power button a second time and you will hear one beep as the machine shuts down. Note that there is a one minute fan delay on shutdown.

2. Arrow Buttons ▲ ▼

Use the up and down arrow buttons to set the desired humidity setpoint on the display screen. The setpoint can be any number between 36-90%. Creating a setpoint means that when the indoor humidity is lower than the set point, the machine will stop automatically. Conversely, when the indoor humidity is higher than the set level, the unit will operate. NOTE: The humidity levels displayed are approximate only (+/- 5%).

3. Continuous Mode ☑

4. Central Control

5. Manual Drain Button

For extended storage or movement of the machine, press the "Drain" button to remove water from the integral pump's reservoir.

6. Pump Trouble Warning

When the pump reservoir water level is too high, the high water sensor will activate to prevent overflow. When this occurs, the dehumidifier will stop the compressor automatically and the display will show "E4". After a 1 minute delay, the fan motor will turn off and the machine will not operate until the problem is resolved. To reset the unit after an "E4" error, check the pump to verify it is functioning, then unplug the unit for two minutes.

7. Auxiliary Terminals A5/A6

The A5/A6 on the terminal strip can be used as a water level warning switch for external condensate pumps.

If an external pump is connected, the pump must have a self-contained power supply and a water level signal line.

Indicator Lights

1. Humidity Display Screen 88

The display screen has two functions:

  1. When the unit is powered on, it shows the humidity of the space.
  2. While setting the desired humidity level, the screen will show the set humidity. After a brief delay, the display will revert to current humidity level.

2. Power Indicator Light ?

This light indicates that the unit is properly powered on and ready to operate. Always make sure the unit is "off" prior to performing any service. When the power light is blinking, it means that the unit has reached the humidity setpoint.

3. Continuous Mode/Auto Defrost Light ?/?

4. Compressor Light ?/?

Remote Control Instructions

Sentinel Dehumidifiers can be controlled using an optional remote accessory. The Sentinel Remote Control connects to your Sentinel Series Dehumidifier via a 25' CAT 5 cable. The Remote control contains an integrated sensor which gives you multiple options for remotely controlling your unit, in addition to monitoring the conditions surrounding the dehumidifier.

One application for the remote control is to install the dehumidifier in one room with the conditioned air ducted into a second room that contains the remote. For example, the dehumidifier could be installed in a laundry room and ducted into a living room. The remote would then be mounted in the living room so the remote sensor can control the humidity and provide easy controls for the user.

Another useful application for the remote control is if the dehumidifier is in area that's difficult to access on a regular basis. For instance, if your dehumidifier is installed in your crawl space, the remote could be mounted in your living space or garage. This provides you with an easy way to monitor the dehumidifier.

1. On/Off (Power) Button ?

Press the on/off button and the machine will start running (one beep). Press the button again to turn the machine off.

2. Up Button ▲ / Down Button ▼

Use the Up and Down arrow buttons to adjust the humidity level.

3. Mode M

Use the Mode button to switch between dehumidification and a ducted application.

4. Temperature T

Press the temperature button to display the current temperature on the screen. Press the button again to turn off the display.

5. Continuous C

Press this button to switch the unit into continuous mode. "Cont." will appear on the display to indicate continuous mode.

6. Drain Pump P

Use this button if the unit will not be in use for an extended period of time. Pressing the drain pump button will remove water from the pump reservoir, so the unit can be safely moved or stored.

NOTE: The symbols mentioned above will only appear when the dehumidifier is powered on.

Remote control diagram: Buttons include Mode, Temperature, On/Off, Up, Down, Continuous, Drain Pump. Features an LCD Monitor and indicators for remote or unit sensor usage.

Operating Instructions

1. Start the machine

Press the power key to turn the machine on.

2. Adjust Settings

Use the up and down arrow keys to adjust your desired setpoint (typically 50-55%).

3. Stop the machine

Press the power key again and the machine will stop. Note the fan will continue to operate for 1 minute after the unit has shut off. NOTE: Do not disconnect power cord to force machine to stop. Always use power button.

4. Water Drainage

The Sentinel HDi90 has both automatic and manual draining. During normal operation, the Sentinel HDi90 will automatically drain as required. If you would like to store or move the machine, you may press the drain button to drain the water from the pump reservoir. The drain will operate for 15 seconds each time the button is pushed. It may be necessary to push the drain button more than once to completely empty the reservoir.

Sentinel HDi90 Diagram

Front View: Power cord, Unit Cover, Inlet End Cap, Handle, Air Inlet Grille, Drain Hose.

Back View: Unit Cover, Control panel, Power cord, Air Outlet Grille, A5/A6 Aux. Terminal (for optional pump, not HDi90 model).

Maintenance

WARNING: Always unplug the unit before doing any maintenance.

Condensate Pump

Your Sentinel HDi90 is equipped with an integral condensate pump designed to pump water from your dehumidifier out to the desired drain. This pump requires routine maintenance that is not covered by your 1 year parts warranty. Only a defective pump will be repaired or replaced during the warranty period.

Preventative Maintenance

As with all pumps, preventative maintenance is necessary to prevent issues from dirt and slime that may accumulate in the drain system. This includes the drain pan, hose to the condensate pump, pump reservoir, pump head float assembly, and discharge tubing.

At least once per year, clean your pump system

Cleaning the machine body

Use a soft damp cloth to clean exterior of unit. Do not use any soap or solvents.

Cleaning the filter

  1. Slide out the filter.
  2. Clean the filter mesh by vacuuming or washing with warm water (no soap or solvents).
  3. Be sure the filter is completely dry before restarting the unit.

Filter cleaning illustration: Shows filter removal, mesh cleaning, and reinsertion steps.

Coil Maintenance

Once per year, clean the coils with an approved coil cleaner. The coil cleaner should be a self-rinsing, foaming cleaner such as WEB® Coil Cleaner.

Electrical Access

Unscrew the 4 screws on the side panel to access the control board.

Pump maintenance

  1. Unscrew the 4 screws on the pump access panel.
  2. Remove the screw on the pump.
  3. Undo the 3 pump quick connects.
  4. Insert a flathead screwdriver into the notch on the side of the pump to help you gently lift the pump off its reservoir (the reservoir remains attached to the unit).

Pump maintenance illustration: Depicts accessing the pump and lifting it from its reservoir.

Cleaning/Disinfecting the Pump

Basic Cleaning (Complete about once a year, depending on environment)

  1. Open the end cap on the filter side of the unit. Press the drain button to drain the reservoir.
  2. Disconnect power to the dehumidifier.
  3. Mix a 16 oz solution of either (1 oz bleach + 15 oz water) OR (4 oz white vinegar + 12 oz water).
  4. Pour solution into the drain tray at the base of the coils. If any cleaning solutions gets on coils, flush with water.
  5. Allow solution to soak for 15 minutes.
  6. Reconnect the dehumidifier to power.
  7. Fill the reservoir with water and flush/cycle the pump at least two times.
  8. If drain line is still filled with debris, repeat process. If still not cleaned, move on to Advanced Cleaning.
  9. Reassemble unit, unless moving on to advanced cleaning.

Advanced Cleaning (Complete as needed)

  1. Press the drain button to drain the water from the reservoir (A wet-dry vacuum or towels can be used to remove any remaining water).
  2. Unplug the the dehumidifier and remove the cover so you have access to the pump.
  3. Remove the pump head from the reservoir by unscrewing the screw. Wipe reservoir clean with a paper towel.
  4. Mix a 16 oz solution of either (1 oz bleach + 15 oz water) OR (4 oz white vinegar+ 12 oz water).
  5. Fill the pump reservoir with cleaning solution.
  6. Reassemble pump, then use manual drain button to flush mixture through discharge tubing.
  7. Pour same cleaning solution slowly into drain tray under evaporator coils and let it clean hose from pan to pump. This process can be stopped when the pump energizes one time. NOTE: If you get any of the cleaning solution on the coils, flush with water.
  8. Pour sufficient clean water through drain pan to allow the pump to turn on twice.
  9. Reassemble the unit and return it to operational status.

Dehumidifier Storage

If the unit will be stored for an extended period of time, complete the following steps:

  1. Turn off the unit and allow to dry
  2. Complete steps #1-3 in Advanced Cleaning (above) to clean out pump reservoir.
  3. Wrap and secure the power cord
  4. Cover filter mesh
  5. Store in clean, dry space

Ducted Applications

Ducting the dehumidifier allows the unit to be in one room while conditioning an adjacent room. The inlet/return grille is designed for 12" flex ducting (optional accessory PN: W-103) while the supply grille is designed for 6" flex ducting.

Ducting Installation

Note: The supply duct adapter is standard on all units. The return duct collar is an optional accessory.

Ducting diagrams: Illustrate removing/installing the duct adapter, and installing/removing flex ducting.

Troubleshooting

SymptomCauseSolution
Machine Won't RunPower SupplyVerify that there is power to the outlet and that the plug is properly installed in outlet.
Low Air FlowAir Filter is CloggedClean the filter mesh according to instructions listed in manual.
Air Inlet or Outlet is BlockedClear the blockage from inlet or outlet.
Loud NoiseMachine Is Not LevelMove the dehumidifier to flat, firm ground.
Filter Mesh is BlockedClean the filter mesh according to instructions listed in manual.
Trouble Code E:1E1=Humidity Sensor IssuesCheck to ensure that wire is connected at both ends. If no issues are visible, the sensor may be faulty.
Trouble Code E: 4Pump has failedVerify that the pump is working. If so, unplug the unit for two minutes, then restart.
Trouble Code: HI or LORoom Temperature Over 104° F (Display HI) or Below 33.8° F (Display LO)The unit is outside the operating temperature range. Modify the room conditions so the temperature is between 33.8° - 104° F and operation will commence. If room conditions are within temperature range, replace defective sensor.

Pump Alarm- Trouble Code E4

If a pump alarm is shown on the display, complete the following steps:

  1. Reset the unit by disconnecting the power cord and then reconnecting it. NOTE: UNIT WILL NOT FUNCTION UNTIL ERROR CODE HAS BEEN CLEARED.
  2. Manually check to see if pump is operational by pressing the drain button. Check if the pump energizes and de-energizes properly. Additionally, check to see if any water purged from the system.
  3. If you haven't cleaned the system recently, check the discharge line for an obstruction, then clean the balance of the pump system (see "Maintenance" on page 8 for details).
  4. Replace the hoses and/or pump, if maintenance alone isn't sufficient.

Sentinel HDi90 Spare Parts

ALL Sentinel Models-Parts

Part#Description
S-100Remote Control Package(cable+remote)
S-101Remote Control
S-102Remote Control Cable,25'
S-103Return Duct Collar Accessory
S-106Duct Kit Assembly(W-103+W-100)
S-107Fiexible Supply Duct, 72"
S-108Main Control Board
S-109Display Board
S-110RH/Temperature Sensor

Sentinel HDi90-Filters

Part#Description
S-915Prefilter
S-916Filter Assembly(Cassette+Prefilter)
S-917MERV-8 Filter

Sentinel HDi90-Parts

Part#Description
S-900Fan Motor
S-901Complete Fan Assembly
S-902Fan Capacitor
S-903Compressor
S-904Compressor Capacitor
S-905Coil Assembly
S-907Condensate Pump Assembly
S-908RH/Temperature Sensor Cable
S-909Display Cable
S-910CAT 5 Prot Internal Cable
S-911Foot,adjustable

Limited Warranty

This limited warranty starts from the date of purchase. Alorair Solutions Inc. warrants to the original purchaser that this ALORAIR product is free from manufacturing defects in material or workmanship for the limited warranty period of:

This limited warranty is valid only on products purchased from the manufacturer or ALORAIR authorized dealer and operated, installed, and maintained according to the instructions included in this user guide or furnished with the product. Alorair Solutions Inc. will not provide in-home service during or after the warranty period. You may be responsible for the shipping charge to bring the product to the manufacturer for service.

To receive warranty service, the purchaser must contact ALORAIR at 888-990-7469 or support@alorair.com. A proof of purchase or order number is required to receive warranty service. During the applicable warranty period, a product will be repaired or replaced at the sole option of ALORAIR.

Limited Warranty Exclusions

This limited warranty covers manufacturing defects in materials or workmanship encountered in normal household, commercial or noncommercial use of this product and shall not cover the following:

The use of this product in SPA or a room with OUTDOOR POOL invalidate or voids limited warranty.

Models: Sentinel HDi90 Basement Dehumidifier with Pump, Sentinel HDi90, Basement Dehumidifier with Pump, Dehumidifier with Pump, Pump, Dehumidifier

PDF preview unavailable. Download the PDF instead.

1680849870.AlorAir-Sentinel-HDi90(Duct-able-Version)User-Manual-20220908 Adobe PDF library 16.00

Related Documents

PreviewAlorAir Sentinel HDi90 Dehumidifier: Installation and Operations Manual
This comprehensive manual details the installation, operation, maintenance, and troubleshooting of the AlorAir Sentinel HDi90 dehumidifier. It covers safety precautions, key features, diagrams, spare parts, and warranty information.
PreviewAlorAir Sentinel HDi65S Installation and Operations Manual | Dehumidifier Guide
Comprehensive installation, operation, maintenance, and troubleshooting guide for the AlorAir Sentinel HDi65S dehumidifier. Learn about key functions, remote control, and warranty information.
PreviewAlorAir Sentinel HD55 & HD55S Installation and Operations Manual
Comprehensive guide for installing and operating the AlorAir Sentinel HD55 and HD55S dehumidifiers, covering safety, setup, functions, maintenance, and troubleshooting.
PreviewAlorAir Sentinel HDi90 Installation and Operations Manual
Comprehensive guide for installing and operating the AlorAir Sentinel HDi90 dehumidifier, covering safety, functions, maintenance, troubleshooting, and warranty information.
PreviewAlorAir Sentinel HDi90 Dehumidifier Specifications and Certifications
Technical specifications and compliance details for the AlorAir Sentinel HDi90 dehumidifier, including power supply, refrigerant type, capacity, and safety certifications like ETL, UL, and CSA.
PreviewAlorAir Sentinel HDi65 Dehumidifier Specifications | ETL Listed, Energy Star
Technical specifications for the AlorAir Sentinel HDi65 dehumidifier, including power supply, refrigerant, capacity, and certifications. Energy Star and ETL Listed.
PreviewAlorAir Sentinel HD55/HD55S Installation and Operations Manual
Comprehensive installation and operations manual for the AlorAir Sentinel HD55 and HD55S dehumidifiers, covering setup, operation, maintenance, troubleshooting, and warranty information.
PreviewAlorAir Sentinel HD90 Dehumidifier: Installation, Operation, and Maintenance Guide
Comprehensive guide for the AlorAir Sentinel HD90 dehumidifier, covering installation, operation, key functions, remote control, maintenance, troubleshooting, and warranty information. Features ENERGY STAR certification.