BLU Products, Inc. BLUC5LMX175 YHLBLUC5LMX175 YHLBLUC5LMX175 bluc5lmx175
REPORT No.SZ23040024W01 TEST REPORT APPLICANT : BLU Products, Inc. PRODUCT NAME : Smart Phone MODEL NAME : C5L MAX BRAND NAME : BLU FCC ID : YHLBLUC5LMX175 STANDARD(S) : 47 CFR Part 15 Subpart C RECEIPT DATE : 2023-04-03 TEST DATE : 2023-04-07 to 2023-05-23 ISSUE DATE : 2023-06-12 Edited by: Zeng Xiaoying (Rapporteur) Approved by: Shen Junsheng (Supervisor) NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 1 of 56 REPORT No.SZ23040024W01 DIRECTORY 1. Summary of Test Result 4 1.1. Testing Applied Standards 5 1.2. Test Equipment List 6 1.3. Measurement Uncertainty 8 1.4. Testing Laboratory 8 2. General Description 9 2.1. Information of Applicant and Manufacturer 9 2.2. Information of EUT 9 2.3. Channel List of EUT 10 2.4. Test Configuration of EUT 11 2.5. Test Conditions 11 2.6. Test Setup Layout Diagram 11 3. Test Results 14 3.1. Antenna Requirement 14 3.2. Duty Cycle of Test Signal 15 3.3. Maximum Peak Conducted Output Power 16 3.4. Maximum Average Conducted Output Power 17 3.5. 6 dB Bandwidth 18 3.6. Conducted Spurious Emissions and Band Edge19 3.7. Power Spectral Density 20 3.8. Conducted Emission21 3.9. Restricted Frequency Bands 22 3.10. Radiated Emission23 Annex A Test Data and Result 25 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 2 of 56 Version 1.0 REPORT No.SZ23040024W01 Change History Date 2023-06-12 Reason for change First edition MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 3 of 56 1. Summary of Test Result REPORT No.SZ23040024W01 No. Section Description Test Date Test Engineer Result Method Determination /Remark 1 15.203 Antenna Requirement N/A N/A PASS No deviation 2 N/A Duty Cycle of Test Signal Apr. 08, 2023 Zhong Yanshan PASS No deviation 3 15.247(b) Maximum Peak Conducted Output Power Apr. 08, 2023 Zhong Yanshan PASS No deviation Maximum 4 15.247(b) Average Conducted Apr. 08, 2023 Zhong Yanshan PASS No deviation Output Power 5 15.247(a) Bandwidth Apr. 08, 2023 Zhong Yanshan PASS No deviation Conducted 6 15.247(d) Spurious Emission and Apr. 08, 2023 Zhong Yanshan PASS No deviation Band Edge 7 15.247(e) Power Spectral Density Apr. 08, 2023 Zhong Yanshan PASS No deviation 8 15.207 Conducted Emission Apr. 12, 2023 Fan Zehang PASS No deviation Restricted 9 15.247(d) Frequency Apr. 26, 2023 Li Hanbin PASS No deviation Bands 10 15.209, 15.247(d) Radiated Emission Apr. 26, 2023 Li Hanbin PASS No deviation Note 1: Measurements to demonstrate compliance with the conducted limits are not required for devices which only employ battery power for operation and which do not operate from the AC power lines or contain provisions for operation while connected to the AC power lines. Note 2: The tests were performed according to the method of measurements prescribed in ANSIC63.10-2013 and KDB558074 D01 v05r02. Note 3: Additions to, deviation, or exclusions from the method shall be judged in the "method determination" column of add, deviate or exclude from the specific method shall be explained in the MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 4 of 56 REPORT No.SZ23040024W01 "Remark" of the above table. Note 4: When the test result is a critical value, we will use the measurement uncertainty give the judgment result based on the 95% confidence intervals. 1.1. Testing Applied Standards According to the specifications of the manufacturer, the EUT must comply with the requirements of the following standards: 47 CFR Part 15 Subpart C Radio Frequency Devices MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 5 of 56 1.2. Test Equipment List REPORT No.SZ23040024W01 1.2.1 Conducted Test Equipments Equipment Name Serial No. EXA Signal Analzyer MY53470836 RF Cable (30MHz-26GHz) CB01 Coaxial Cable CB02 SMA Connector CN01 Type N9010A RF01 RF02 RF03 Manufacturer Agilent Cal. Date 2023.02.27 Morlab N/A Morlab N/A HUBER-SUHNER N/A Due Date 2024.02.26 N/A N/A N/A 1.2.2 Conducted Emission Test Equipments Equipment Name Serial No. Type Receiver MY56400093 N9038A LISN Pulse Limiter (10dB) RF Coaxial Cable (DC-100MHz) 8127449 VTSD 9561 F-B #206 BNC NSLK 8127 VTSD 9561-F MRE04 Manufacturer KEYSIGHT Cal. Date Due Date 2023.02.09 2024.02.08 Schwarzbeck 2023.02.21 2024.02.20 Schwarzbeck 2022.07.06 2023.07.05 Qualwave 2022.07.08 2023.07.07 1.2.3 List of Software Used Description Test System Morlab EMCR V1.2 TS+ -[JS32-CE] Manufacturer MaiWei Morlab Tonscend Software Version 2.0.0.0 V1.0 V2.5.0.0 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 6 of 56 REPORT No.SZ23040024W01 1.2.4 Radiated Test Equipments Equipment Name Serial No. Receiver MY54130016 Test Antenna Bi-Log 9163-519 Test Antenna Loop 1519-022 Test Antenna Horn 01774 Test Antenna BBHA9170 Horn #773 Preamplifier (10MHz-6GHz) 46732 Preamplifier (2GHz-18GHz) 61171/61172 Preamplifier (18GHz-40GHz) DS77209 Type N9038A VULB 9163 FMZB1519 BBHA 9120D BBHA9170 S10M100L38 02 S020180L32 03 DCLNA0118- 40C-S RF Coaxial Cable (DC-18GHz) MRE001 PE330 RF Coaxial Cable (DC-18GHz) RF Coaxial Cable (DC-18GHz) RF Coaxial Cable (DC-40GHz) RF Coaxial Cable (DC-40GHz) RF Coaxial Cable (DC-18GHz) Notch Filter Anechoic Chamber MRE002 MRE003 22290045 22290046 22120181 N/A N/A CLU18 CLU18 QA360-40-K K-0.5 QA360-40-K KF-2 QA500-18-N N-5 WRCG-24002483.5-60SS 9m*6m*6m Manufacturer Agilent Schwarzbeck Schwarzbeck Schwarzbeck Schwarzbeck LUCIX CORP. LUCIX CORP. Decentest Pasternack Pasternack Pasternack Qualwave Qualwave Qualwave Wainwright CRT Cal. Date 2022.07.06 2022.05.25 2022.02.11 2022.07.13 2022.07.14 2022.07.08 2022.07.08 2022.07.23 2022.07.08 2022.07.08 2022.07.08 2022.07.08 2022.07.08 2022.07.08 2022.07.08 2022.05.10 Due Date 2023.07.05 2025.05.24 2025.02.10 2025.07.12 2025.07.13 2023.07.07 2023.07.07 2023.07.22 2023.07.07 2023.07.07 2023.07.07 2023.07.07 2023.07.07 2023.07.07 2023.07.07 2025.05.09 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 7 of 56 1.3. Measurement Uncertainty REPORT No.SZ23040024W01 Test Items Peak Output Power Power Spectral Density Bandwidth Conducted Spurious Emission Restricted Frequency Bands Radiated Emission Conducted Emission 1.4. Testing Laboratory Uncertainty ±2.22dB ±2.22dB ±5% ±2.77dB ±5% ±2.95dB ±2.44dB Remark Confidence levels of 95% Confidence levels of 95% Confidence levels of 95% Confidence levels of 95% Confidence levels of 95% Confidence levels of 95% Confidence levels of 95% Laboratory Name Laboratory Address Telephone Facsimile FCC Designation Number FCC Test Firm Registration Number Shenzhen Morlab Communications Technology Co., Ltd. FL.3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China +86 755 36698555 +86 755 36698525 CN1192 226174 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 8 of 56 2. General Description REPORT No.SZ23040024W01 2.1. Information of Applicant and Manufacturer Applicant Applicant Address Manufacturer Manufacturer Address BLU Products, Inc. 8600 NW 36th Street, Suite #200 Doral, FL 33166, USA BLU Products, Inc. 8600 NW 36th Street, Suite #200 Doral, FL 33166, USA 2.2. Information of EUT Product Name: Sample No.: Hardware Version: Software Version: Equipment Type: Bluetooth Version: Modulation Type: Data Rate: Operating Frequency Range: Antenna Type: Antenna Gain: Accessory Information: Smart Phone 1# A507-MB-V3.6D A507-37H_sp9832e_1h10_go2g-userdebug-native_0307_144 3 Bluetooth LE 4.2 GFSK 1Mbps 2402MHz-2480MHz PIFA Antenna -0.62dBi Battery Brand Name: BLU Model No.: C775444200L Serial No.: N/A Capacity: 2000mAh Rated Voltage: 3.8V Charge Limit: 4.35V Manufacturer: Shenzhen Aerospace Electronic Co.,Ltd. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 9 of 56 REPORT No.SZ23040024W01 Adaptor Brand Name: BLU Model No.: US-JY-1000 Accessory Information: Serial No.: Rated Output: N/A 5V 1000mA Rated Input: 100-240V 50/60Hz, 0.3A Manufacturer: Dongguan Jieyuan Electronic Technology Co., LTD Note 1: We use the dedicated software to control the EUT continuous transmission. Note 2: For a more detailed description, please refer to Specification or User's Manual supplied by the applicant and/or manufacturer. 2.3. Channel List of EUT Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) 0 2402 10 2422 20 2442 30 2462 1 2404 11 2424 21 2444 31 2464 2 2406 12 2426 22 2446 32 2466 3 2408 13 2428 23 2448 33 2468 4 2410 14 2430 24 2450 34 2470 5 2412 15 2432 25 2452 35 2472 6 2414 16 2434 26 2454 36 2474 7 2416 17 2436 27 2456 37 2476 8 2418 18 2438 28 2458 38 2478 9 2420 19 2440 29 2460 39 2480 Note 1: The black bold channels were selected for test. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 10 of 56 2.4. Test Configuration of EUT REPORT No.SZ23040024W01 Test mode is used to control the EUT under the maximum power level during test. 2.5. Test Conditions Temperature (°C) Relative Humidity (%) Atmospheric Pressure (kPa) 15-35 30-60 86-106 2.6. Test Setup Layout Diagram 2.6.1.Conducted Measurement 2.6.2.Conducted Emission Measurement MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 11 of 56 2.6.3.Radiation Measurement 1) For radiated emissions from 9kHz to 30MHz REPORT No.SZ23040024W01 2) For radiated emissions from 30MHz to1GHz MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 12 of 56 3) For radiated emissions above 1GHz REPORT No.SZ23040024W01 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 13 of 56 3. Test Results REPORT No.SZ23040024W01 3.1. Antenna Requirement 3.1.1.Requirement According to FCC 15.203, an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this section. 3.1.2.Test Result Inside of the EUT has a PIFA antenna coupled with the metal shrapnel. Please refer to the EUT internal photos. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 14 of 56 3.2. Duty Cycle of Test Signal REPORT No.SZ23040024W01 3.2.1.Requirement Preferably, all measurements of maximum conducted (average) output power will be performed with the EUT transmitting continuously (i.e., with a duty cycle of greater than or equal to 98%).When continuous operation cannot be realized, then the use of sweep triggering/signal gating techniques can be used to ensure that measurements are made only during transmissions at the maximum power control level. Such sweep triggering/signal gating techniques will require knowledge of the minimum transmission duration(T) over which the transmitter is on and is transmitting at its maximum power control level for the tested mode of operation. Sweep triggering/signal gating techniques can then be used if the measurement/sweep time of the analyzer can be set such that it does not exceed T at any time that data are being acquired (i.e.,no transmitter OFF-time is to be considered). When continuous transmission cannot be achieved and sweep triggering/signal gating cannot be implemented, alternative procedures are provided that can be used to measure the average power; however, they will require an additional measurement of the transmitter duty cycle (D). Within this sub clause, the duty cycle refers to the fraction of time over which the transmitter is ON and is transmitting at its maximum power control level. The duty cycle is considered to be constant if variations are less than ±2%; otherwise, the duty cycle is considered to be non constant. 3.2.2.Test Result Refer to Annex A.1 in this report. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 15 of 56 REPORT No.SZ23040024W01 3.3. Maximum Peak Conducted Output Power 3.3.1.Requirement According to FCC section 15.247(b)(3), For systems using digital modulation in the 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz bands: The maximum peak conducted output power of the intentional radiator shall not exceed 1 Watt. 3.3.2.Test Procedures KDB 558074 Section 8.3.1 was used in order to prove compliance. 3.3.3.Test Setup Layout Refer to chapter 2.6.1 in this report. 3.3.4.Test Result Refer to Annex A.2 in this report. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 16 of 56 REPORT No.SZ23040024W01 3.4. Maximum Average Conducted Output Power 3.4.1.Requirement According to FCC section 15.247(b)(3), for systems using digital modulation in the 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz bands: The maximum average conducted output power of the intentional radiator shall not exceed 1 Watt. 3.4.2.Test Procedures KDB 558074 Section 8.3.2 was used in order to prove compliance. 3.4.3.Test Setup Layout Refer to chapter 2.6.1 in this report. 3.4.4.Test Result Refer to Annex A.3 in this report. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 17 of 56 3.5. 6 dB Bandwidth REPORT No.SZ23040024W01 3.5.1.Requirement According to FCC section 15.247(a) (2), systems using digital modulation techniques may operate in the 902 - 928 MHz, 2400 - 2483.5 MHz, and 5725 - 5850 MHz bands. The minimum 6dB bandwidth shall be at least 500 kHz. 3.5.1.Test Procedures The steps for the first option are as follows: a) Set analyzer center frequency to channel center frequency b) Set RBW to100kHz c) Set VBW to 300kHz d) Detector = peak. e) Trace mode = max hold f) Sweep time = auto couple g) Allow the trace to fully stabilize h) Measure the maximum width of the emission that is constrained by the frequencies associated with the two outermost amplitude points (upper and lower frequencies) that are attenuated by6 dB relative to the maximum level measured in the fundamental emission The automatic bandwidth measurement capability of an instrument may be employed using the X dB bandwidth mode with X set to 6 dB, if the functionality described in 11.8.1 (i.e., RBW = 100 kHz, VBW 3 ×RBW, and peak detector with maximum hold) is implemented by the instrumentation function. When using this capability, care shall be taken so that the bandwidth measurement is not influenced by any intermediate power nulls in the fundamental emission that might be 6 dB. 3.5.2.Test Setup Layout Refer to chapter 2.6.1 in this report. 3.5.3.Test Result Refer to Annex A.4 in this report. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 18 of 56 REPORT No.SZ23040024W01 3.6. Conducted Spurious Emissions and Band Edge 3.6.1.Requirement According to FCC section 15.247(d), in any 100kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20dB below that in the 100kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement. 3.6.2.Test Procedures KDB 558074 Section 8.5 and 8.7 was used in order to prove compliance. 3.6.3.Test Setup Layout Refer to chapter 2.6.1 in this report. 3.6.4.Test Result Refer to Annex A.5 and A.6 in this report. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 19 of 56 3.7. Power Spectral Density REPORT No.SZ23040024W01 3.7.1.Requirement For digitally modulated systems, the power spectral density conducted from the intentional radiator to the antenna shall not be greater than 8dBm in any 3 kHz band during any time interval of continuous transmission. This power spectral density shall be determined in accordance with the provisions of paragraph (b) of this section. The same method of determining the conducted output power shall be used to determine the power spectral density. 3.7.2.Test Procedures The measured power spectral density was calculated by the reading of the spectrum analyzer and calibration. Following is the test procedure for PSD test: a) Set analyzer center frequency to channel center frequency b) Set span to1.5 times DTS c) Set RBW to 3kHz d) Set VBW to 10kHz e) Detector = peak f) Sweep time = auto couple g) Trace mode = max hold h) Allow trace to fully stabilize i) Use the peak marker function to determine the maximum amplitude level within the RBW 3.7.3.Test Setup Layout Refer to chapter 2.6.1 in this report. 3.7.4.Test Result Refer to Annex A.7 in this report. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 20 of 56 3.8. Conducted Emission REPORT No.SZ23040024W01 3.8.1.Requirement According to FCC section 15.207, for an intentional radiator that is designed to be connected to the public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in the following table, as measured using a 50µH/50 line impedance stabilization network (LISN). Frequency Range (MHz) Conducted Limit (dBµV) Quai-peak Average 0.15 - 0.50 66 to 56 56 to 46 0.50 - 5 56 46 5 - 30 60 50 Note: (a) The lower limit shall apply at the band edges. (b) The limit decreases linearly with the logarithm of the frequency in the range 0.15 - 0.50MHz. 3.8.2.Test Procedures The Table-top EUT was placed upon a non-metallic table 0.8m above the horizontal metal reference ground plane. EUT was connected to LISN and LISN was connected to reference Ground Plane. EUT was 80cm from LISN. The set-up and test methods were according to ANSI C63.10: 2013. 3.8.3.Test Setup Layout Refer to chapter 2.6.2 in this report. 3.8.4.Test Result Refer to Annex A.8 in this report. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 21 of 56 3.9. Restricted Frequency Bands REPORT No.SZ23040024W01 3.9.1.Requirement According to FCC section 15.247(d), in any 100kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20dB below that in the 100kHz bandwidth within the band that contains the highest level of the desired power, In addition, radiated emissions which fall in the restricted bands, as defined in 15.205(a), must also comply with the radiated emission limits specified in 15.209(a). 3.9.2.Test Procedures The EUT is located in a 3m Semi-Anechoic Chamber; the antenna factors, cable loss and so on of the site as factors are calculated to correct the reading. For the Test Antenna: Test Antenna is 3m away from the EUT. Test Antenna height is varied from 1m to 4m above the ground to determine the maximum value of the field strength. Span = wide enough to fully capture the emission being measured RBW = 1 MHz for f 1GHz, 100 kHz for f < 1GHz VBW = 3 MHz Sweep = auto Detector function = peak/average Trace = max hold Allow the trace to stabilize 3.9.3.Test Setup Layout Refer to chapter 2.6.3 in this report. 3.9.4.Test Result Refer to Annex A.8 in this report. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 22 of 56 3.10. Radiated Emission REPORT No.SZ23040024W01 3.10.1.Requirement According to FCC section 15.247(d), radiated emission outside the frequency band attenuation below the general limits specified in FCC section 15.209(a) is not required. In addition, radiated emissions which fall in the restricted bands, as defined in FCC section 15.205(a), must also comply with the radiated emission limits specified in FCC section 15.209(a). According to FCC section 15.209 (a), except as provided elsewhere in this subpart, the emissions from an intentional radiator shall not exceed the field strength levels specified in the following table: Frequency (MHz) Field Strength (µV/m) Measurement Distance (m) 0.009 - 0.490 2400/F(kHz) 300 0.490 - 1.705 24000/F(kHz) 30 1.705 - 30.0 30 30 30 - 88 100 3 88 - 216 150 3 216 - 960 200 3 Above 960 500 3 Note1: For above 1000MHz, the emission limit in this paragraph is based on measurement instrumentation employing an average detector, measurement using instrumentation with a peak detector function, corresponding to 20dB above the maximum permitted average limit. Note2:For above 1000MHz, limit field strength of harmonics: 54dBuV/m@3m (AV) and 74dBuV/m@3m (PK).In addition, radiated emissions which fall in the restricted bands, as defined in Section 15.205(a), also should comply with the radiated emission limits specified in Section 15.209(a)(above table). MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 23 of 56 REPORT No.SZ23040024W01 3.10.2.Test Procedures The EUT is placed on a non-conducting table 80 cm above the ground plane for measurement below 1GHz; 1.5 m above the ground plane for measurement above 1GHz.The antenna to EUT distance is 3meters. The EUT is configured in accordance with ANSI C63.10. The EUT is set to transmit in a continuous mode. For measurements below 30MHz, the emission limits shown in the above table are based on measurements employing a CISPR quasi-peak detector except for the frequency bands 9kHz-90 kHz, 110kHz-490 kHz. Radiated emission limits in these two bands are based on measurements employing an average detector. For measurements below 1GHz the resolution bandwidth is set to 100kHz for peak detection measurements or 120kHz for quasi-peak detection measurements. Peak detection is used unless otherwise noted as quasi-peak. For measurements above 1GHz the resolution bandwidth is set to 1MHz, the video band width is set to 3MHz for peak measurements and as applicable for average measurements. The EUT is rotated through 360 degrees to maximize emissions received. The antenna is scanned from 1 to 4 meters above the ground plane to further maximize the emission. Measurements are made with the antenna polarized in both the vertical and the horizontal positions. For measurements above 1 GHz, keeping the measurement antenna aimed at the source of emissions at each frequency of significant emissions, with polarization oriented for maximum response. 3.10.3.Test Setup Layout Refer to chapter 2.6.3 in this report. 3.10.4.Test Result Refer to Annex A.9 in this report. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 24 of 56 REPORT No.SZ23040024W01 Annex A Test Data and Result A.1. Duty Cycle of Test Signal Condition NVNT NVNT NVNT Mode BLE 1M BLE 1M BLE 1M Frequency (MHz) 2402 2440 2480 Antenna Ant1 Ant1 Ant1 Duty Cycle (%) 63.15 63.12 63.12 Correction Factor (dB) 2 2 2 1/T (kHz) 2.53 2.53 2.53 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 25 of 56 REPORT No.SZ23040024W01 Test Graphs Duty Cycle NVNT BLE 1M 2402MHz Ant1 Duty Cycle NVNT BLE 1M 2440MHz Ant1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 26 of 56 REPORT No.SZ23040024W01 Duty Cycle NVNT BLE 1M 2480MHz Ant1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 27 of 56 REPORT No.SZ23040024W01 A.2. Maximum Peak Conducted Output Power Condition Mode NVNT NVNT NVNT BLE 1M BLE 1M BLE 1M Frequency Conducted Antenna (MHz) Power (dBm) 2402 2440 2480 Ant1 Ant1 Ant1 2.28 0.74 -0.70 Duty Factor (dB) 0 0 0 Total Power (dBm) 2.28 0.74 -0.70 Limit Verdict (dBm) 30 Pass 30 Pass 30 Pass MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 28 of 56 REPORT No.SZ23040024W01 Test Graphs Peak Power NVNT BLE 1M 2402MHz Ant1 Peak Power NVNT BLE 1M 2440MHz Ant1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 29 of 56 REPORT No.SZ23040024W01 Peak Power NVNT BLE 1M 2480MHz Ant1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 30 of 56 REPORT No.SZ23040024W01 A.3. Maximum Average Conducted Output Power Condition Mode Frequency Conducted Antenna (MHz) Power (dBm) NVNT NVNT NVNT BLE 1M BLE 1M BLE 1M 2402 2440 2480 Ant1 Ant1 Ant1 -0.22 -1.65 -3.29 Duty Factor (dB) 2 2 2 Total Power (dBm) 1.78 0.35 -1.29 Limit Verdict (dBm) 30 Pass 30 Pass 30 Pass MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 31 of 56 REPORT No.SZ23040024W01 Test Graphs Average Power NVNT BLE 1M 2402MHz Ant1 Average Power NVNT BLE 1M 2440MHz Ant1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 32 of 56 REPORT No.SZ23040024W01 Average Power NVNT BLE 1M 2480MHz Ant1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 33 of 56 REPORT No.SZ23040024W01 A.4. 6 dB Bandwidth Condition Mode NVNT NVNT NVNT BLE 1M BLE 1M BLE 1M Frequency (MHz) 2402 2440 2480 Antenna Ant1 Ant1 Ant1 -6 dB Bandwidth (MHz) 0.655 0.659 0.651 Limit -6 dB Bandwidth (MHz) 0.5 0.5 0.5 Verdict Pass Pass Pass MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 34 of 56 REPORT No.SZ23040024W01 Test Graphs -6dB Bandwidth NVNT BLE 1M 2402MHz Ant1 -6dB Bandwidth NVNT BLE 1M 2440MHz Ant1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 35 of 56 REPORT No.SZ23040024W01 -6dB Bandwidth NVNT BLE 1M 2480MHz Ant1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 36 of 56 REPORT No.SZ23040024W01 A.5. Conducted Spurious Emissions Condition NVNT NVNT NVNT Mode BLE 1M BLE 1M BLE 1M Frequency (MHz) 2402 2440 2480 Antenna Ant1 Ant1 Ant1 Max Value (dBc) -39.33 -37.63 -36.48 Limit (dBc) -20 -20 -20 Verdict Pass Pass Pass MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 37 of 56 REPORT No.SZ23040024W01 Test Graphs Tx. Spurious NVNT BLE 1M 2402MHz Ant1 Ref Tx. Spurious NVNT BLE 1M 2402MHz Ant1 Emission MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 38 of 56 REPORT No.SZ23040024W01 Tx. Spurious NVNT BLE 1M 2440MHz Ant1 Ref Tx. Spurious NVNT BLE 1M 2440MHz Ant1 Emission MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 39 of 56 REPORT No.SZ23040024W01 Tx. Spurious NVNT BLE 1M 2480MHz Ant1 Ref Tx. Spurious NVNT BLE 1M 2480MHz Ant1 Emission MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 40 of 56 REPORT No.SZ23040024W01 A.6. Band Edge Condition NVNT NVNT Mode BLE 1M BLE 1M Frequency (MHz) 2402 2480 Antenna Ant1 Ant1 Max Value (dBc) -56.22 -54.18 Limit (dBc) -20 -20 Verdict Pass Pass MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 41 of 56 REPORT No.SZ23040024W01 Test Graphs Band Edge NVNT BLE 1M 2402MHz Ant1 Ref Band Edge NVNT BLE 1M 2402MHz Ant1 Emission MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 42 of 56 REPORT No.SZ23040024W01 Band Edge NVNT BLE 1M 2480MHz Ant1 Ref Band Edge NVNT BLE 1M 2480MHz Ant1 Emission MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 43 of 56 REPORT No.SZ23040024W01 A.7. Power Spectral Density Condition NVNT NVNT NVNT Mode BLE 1M BLE 1M BLE 1M Frequency (MHz) 2402 2440 2480 Antenna Ant1 Ant1 Ant1 Conducted PSD (dBm/3kHz) -14.25 -15.93 -16.06 Duty Factor (dB) 0 0 0 Total PSD (dBm/3kHz) -14.25 -15.93 -16.06 Limit (dBm/3kHz) 8 8 8 Verdict Pass Pass Pass MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 44 of 56 REPORT No.SZ23040024W01 Test Graphs PSD NVNT BLE 1M 2402MHz Ant1 PSD NVNT BLE 1M 2440MHz Ant1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 45 of 56 REPORT No.SZ23040024W01 PSD NVNT BLE 1M 2480MHz Ant1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 46 of 56 REPORT No.SZ23040024W01 A.8. Conducted Emission The maximum conducted interference is searched using Peak (PK), if the emission levels more than the AV and QP limits, and that have narrow margins from the AV and QP limits will be re-measured with AV and QP detectors. Tests for both L phase and N phase lines of the power mains connected to the EUT are performed. Set RBW=9kHz, VBW=30kHz. Refer to recorded points and plots below. Note: Both of the test voltage AC 120V/60Hz and AC 230V/50Hz were considered and tested respectively, only the results of the worst case AC 120V/60Hz were recorded in this report. A. Test Setup: Test Mode: EUT + Adapter + USB Cable + Earphone + BT TX Test voltage: AC 120V/60Hz The measurement results are obtained as below: E [dBV] =UR + LCable loss [dB] + AFactor UR: Receiver Reading AFactor: Voltage division factor of LISN MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 47 of 56 B. Test Plot: REPORT No.SZ23040024W01 (L Phase) No. Fre. (MHz) Emission Level (dBµV) Quai-peak Average 1 0.1546 41.58 28.46 2 0.3704 32.04 26.09 3 0.4338 31.05 24.81 4 0.5489 39.32 31.59 5 0.5755 41.96 34.57 6 0.6188 34.48 27.87 Limit (dBµV) Quai-peak 65.75 58.49 57.18 56.00 56.00 56.00 Average 55.75 48.49 47.18 46.00 46.00 46.00 Power-line Verdict PASS PASS Line PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 48 of 56 REPORT No.SZ23040024W01 (N Phase) No. Fre. (MHz) Emission Level (dBµV) Quai-peak Average 1 0.1551 41.10 30.96 2 0.1684 39.99 30.53 3 0.5111 41.55 34.21 4 0.5486 48.78 38.39 5 0.5758 50.23 39.81 6 0.6245 42.72 31.05 Limit (dBµV) Quai-peak 65.72 65.04 56.00 56.00 56.00 56.00 Average 55.72 55.04 46.00 46.00 46.00 46.00 Power-line Verdict Neutral PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 49 of 56 REPORT No.SZ23040024W01 A.9. Restricted Frequency Bands The lowest and highest channels are tested to verify the Restricted Frequency Bands. The measurement results are obtained as below: E [dBV/m] =UR + AT + AFactor [dB]; AT =LCable loss [dB]-Gpreamp [dB] AT: Total correction Factor except Antenna UR: Receiver Reading Gpreamp: Preamplifier Gain AFactor: Antenna Factor at 3m Note: Restricted Frequency Bands were performed when antenna was at vertical and horizontal polarity, and only the worse test condition (vertical) was recorded in this test report. Receiver Max. Channel Frequency (MHz) Detector PK/ AV Reading UR (dBµV) AT (dB) AFactor (dB@3m) Emission E (dBµV/m) Limit (dBµV/m) Verdict 0 2344.30 PK 24.91 6.74 27.20 58.85 74 PASS 0 2387.67 AV 11.76 6.74 27.20 45.70 54 PASS 39 2485.04 PK 24.29 6.74 27.20 58.23 74 PASS 39 2494.94 AV 11.42 6.74 27.20 45.36 54 PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 50 of 56 REPORT No.SZ23040024W01 (PEAK, Channel 0) (AVERAGE, Channel 0) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 51 of 56 REPORT No.SZ23040024W01 (PEAK, Channel 39) (AVERAGE, Channel 39) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 52 of 56 REPORT No.SZ23040024W01 A.10. Radiated Emission According to ANSI C63.10, because of peak detection will yield amplitudes equal to or greater than amplitudes measured with the quasi-peak (or average) detector, the measurement data from a spectrum analyzer peak detector will represent the worst-case results, if the peak measured value complies with the quasi-peak (or average) limit, it is unnecessary to perform an quasi-peak measurement (or average). The measurement results are obtained as below: E [dBV/m] =UR + AT + AFactor [dB]; AT =LCable loss [dB]-Gpreamp [dB] AT: Total correction Factor except Antenna UR: Receiver Reading Gpreamp: Preamplifier Gain AFactor: Antenna Factor at 3m During the test, the total correction Factor AT and AFactor were built in test software. Note1: All radiated emission tests were performed in X, Y, Z axis direction. And only the worst axis test condition was recorded in this test report. Note2: For the frequency, which started from 9kHz to 30MHz, was pre-scanned and the result which was 20dB lower than the limit was not recorded. Note3: For the frequency, which started from 18GHz to 10th harmonic of the highest frequency, was pre-scanned and the result which was 20dB lower than the limit was not recorded. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 53 of 56 Plot for Channel 0 REPORT No.SZ23040024W01 Fre. (MHz) 109.540 1884.800 2454.933 5713.880 10435.520 12597.680 PK (dBV/m) 33.36 47.67 47.54 48.25 47.97 48.70 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Horizontal, 30MHz to 18GHz) Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict PASS PASS PASS PASS PASS PASS Fre. (MHz) 102.750 1826.133 2451.200 5649.200 8350.360 12690.080 PK (dBV/m) 33.79 47.52 47.60 48.28 48.20 48.02 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Vertical, 30MHz to 18GHz) Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 54 of 56 Plot for Channel 19 REPORT No.SZ23040024W01 Fre. (MHz) 109.540 1359.467 2408.533 4543.480 8461.240 12529.920 PK (dBV/m) 33.70 47.76 47.88 47.82 47.89 48.63 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Horizontal, 30MHz to 18GHz) Antenna Verdict Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal PASS PASS PASS PASS PASS PASS Fre. (MHz) 103.720 2010.133 2491.733 5760.080 8371.920 12132.600 PK (dBV/m) 33.03 47.55 47.80 48.03 48.07 48.38 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Vertical, 30MHz to 18GHz) Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 55 of 56 Plot for Channel 39 REPORT No.SZ23040024W01 Fre. (MHz) 100.810 1576.000 2002.667 5673.840 8313.400 13059.680 PK (dBV/m) 34.17 47.41 47.70 47.62 48.46 48.72 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Horizontal, 30MHz to 18GHz) Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict PASS PASS PASS PASS PASS PASS Fre. (MHz) 106.630 1496.000 1994.667 5726.200 8427.360 12175.720 PK (dBV/m) 32.77 47.00 49.01 47.63 47.58 48.35 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Vertical, 30MHz to 18GHz) Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict PASS PASS PASS PASS PASS PASS END OF REPORT MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 56 of 56Acrobat Distiller 9.3.2 (Windows)