3 gen 2024 — As part of the Toshiba Carrier U-Series VRF product launch, we are introducing the new u-Series line of heat recovery units. The new u-Series heat recovery ...
Product Bulletin Date 1/3/24 Bulletin Number VRF-23-015 Subject New Toshiba Carrier u-Series Heat Recovery Product Model Number(s) MMY-UP***1FT6(9)P (u-Series Heat Recovery) MMY-UP***H1FT6(9)P (u-Series Elite Heat Unit) Department Product Marketing Author Name/Email Steven Hunt steven.hunt2@carrier.com New Toshiba Carrier u-Series Heat Recovery Unit As part of the Toshiba Carrier U-Series VRF product launch, we are introducing the new u-Series line of heat recovery units. The new u-Series heat recovery units offer a standard version of the heat pump up to 42 tons. The new series of heat pumps will also feature an Elite Heat unit that will give additional heating performance in cold climates. The new u-Series heat recovery units are not backwards compatible and will require both uSeries indoor units and u-Series controllers. u-Series Heat Recovery MMY-MUP***1FT6(9)P-UL 6 42 tons u-Series `Elite Heat' Heat Recovery MMY-MUP***H1FT6(9)PUL 6 30 tons The new u-Series heat recovery units will be available for purchase upon the sale of the existing eSeries units. Elite Heat units will be available for purchase January 2024. Documentation will be available in HVACpartners prior to the release of the heat recovery units January 31, 2024. The new u-Series heat recovery units will be available to be modeled in VPro by January 2023, as you will not have the ability to construct these systems in the VRoom software. ©2023 Carrier Confidential & Proprietary Not For Further Distribution 1 Product Bulletin Appendix Table 1 u-Series Heat Recovery Nomenclature Table 2 u-Series Multi-Module Heat Recovery Pairings (230V) Table 3 u-Series Multi-Module Elite Heat Heat Recovery Pairings (230V) Table 4 u-Series Multi-Module Heat Recovery Pairings (460V) Table 5 u-Series Multi-Module Elite Heat Heat Recovery Pairings (460V) Table 6 Dimensional Comparison to e-Series Heat Recovery Table 7 Electrical Rating Comparison to e-Series Heat Recovery Table 8 Sound Measurement Comparison to e-Series Heat Recovery Table 9 AHRI Performance ©2023 Carrier Confidential & Proprietary Not For Further Distribution 2 Product Bulletin Table 1 - u-Series Heat Recovery Nomenclature Title Product #/Letter Description 1 - 3 Multi Modular Unit 4 Model Identifier 5 Communicatio n 6 Refrigeran t Type 7 - 9 Nominal Capacity 10 Heat Pump Type 11 Model Identifier 12 Power Supply 13 Assembling Factory 14 Model Identifie r 15 - 16 Region MMY - M U P *** 1 F 9 P - UL MMY = Modular Multi M = Single Module Unit Blank = Multi Module Unit U = New Communicatio n (TU2C-LINK) P = Refrigeran t R410A 072 - 480 (Nominal Capacity) 1 = Standard Model H1 = High Heat Model F = Heat Recovery Unit 6 = 460V 9 = 208/230 V P = Thailand - = Standar d Model Blank = High Heat Model UL =- USA / Canada Table 2 - Multi Module Heat Recovery Combinations 208/230V Model # MMY-UP1921FT9P-UL MMY-UP2161FT9P-UL MMY-UP2401FT9P-UL MMY-UP2641FT9P-UL MMY-UP2881FT9P-UL MMY-UP3121FT9P-UL MMY-UP3361FT9P-UL MMY-UP3601FT9P-UL MMY-UP3841FT9P-UL MMY-UP4081FT9P-UL MMY-UP4321FT9P-UL MMY-UP4561FT9P-UL MMY-UP4801FT9P-UL MMY-UP5041FT9P-UL Header MMY-MUP0961FT9P-UL MMY-MUP1441FT9P-UL MMY-MUP1441FT9P-UL MMY-MUP1681FT9P-UL MMY-MUP1441FT9P-UL MMY-MUP1681FT9P-UL MMY-MUP1681FT9P-UL MMY-MUP1681FT9P-UL MMY-MUP1441FT9P-UL MMY-MUP1681FT9P-UL MMY-MUP1681FT9P-UL MMY-MUP1681FT9P-UL MMY-MUP1681FT9P-UL MMY-MUP1681FT9P-UL Combination Follower MMY-MUP0961FT9P-UL MMY-MUP0721FT9P-UL MMY-MUP0961FT9P-UL MMY-MUP0961FT9P-UL MMY-MUP1441FT9P-UL MMY-MUP1441FT9P-UL MMY-MUP1681FT9P-UL MMY-MUP0961FT9P-UL MMY-MUP1441FT9P-UL MMY-MUP1441FT9P-UL MMY-MUP1681FT9P-UL MMY-MUP1441FT9P-UL MMY-MUP1681FT9P-UL MMY-MUP1681FT9P-UL Follower ------------------------- MMY-MUP0961FT9P-UL MMY-MUP0961FT9P-UL MMY-MUP0961FT9P-UL MMY-MUP0961FT9P-UL MMY-MUP1441FT9P-UL MMY-MUP1441FT9P-UL MMY-MUP1681FT9P-UL ©2023 Carrier Confidential & Proprietary Not For Further Distribution 3 Product Bulletin Table 3 - Elite Heat Multi Module Heat Recovery Combinations 208/230V Model # MMY-UP144H1FT9PUL MMY-UP192H1FT9PUL MMY-UP240H1FT9PUL MMY-UP288H1FT9PUL MMY-UP360H1FT9PUL Header MMY-MUP072H1FT9PUL MMY-MUP096H1FT9PUL MMY-MUP120H1FT9PUL MMY-MUP096H1FT9PUL MMY-MUP120H1FT9PUL Combination Follower MMY-MUP072H1FT9PUL MMY-MUP096H1FT9PUL MMY-MUP120H1FT9PUL MMY-MUP096H1FT9PUL MMY-MUP120H1FT9PUL Follower ------------MMY-MUP096H1FT9PUL MMY-MUP120H1FT9PUL Table 4 Multi Module Heat Recovery Combinations 460V Model # MMY-UP1921FT6P-UL MMY-UP2161FT6P-UL MMY-UP2401FT6P-UL MMY-UP2641FT6P-UL MMY-UP2881FT6P-UL MMY-UP3121FT6P-UL MMY-UP3361FT6P-UL MMY-UP3601FT6P-UL MMY-UP3841FT6P-UL MMY-UP4081FT6P-UL MMY-UP4321FT6P-UL MMY-UP4561FT6P-UL MMY-UP4801FT6P-UL MMY-UP5041FT6P-UL Header MMY-MUP0961FT6P-UL MMY-MUP1441FT6P-UL MMY-MUP1441FT6P-UL MMY-MUP1681FT6P-UL MMY-MUP1441FT6P-UL MMY-MUP1681FT6P-UL MMY-MUP1681FT6P-UL MMY-MUP1681FT6P-UL MMY-MUP1441FT6P-UL MMY-MUP1681FT6P-UL MMY-MUP1681FT6P-UL MMY-MUP1681FT6P-UL MMY-MUP1681FT6P-UL MMY-MUP1681FT6P-UL Combination Follower MMY-MUP0961FT6P-UL MMY-MUP0721FT6P-UL MMY-MUP0961FT6P-UL MMY-MUP0961FT6P-UL MMY-MUP1441FT6P-UL MMY-MUP1441FT6P-UL MMY-MUP1681FT6P-UL MMY-MUP0961FT6P-UL MMY-MUP1441FT6P-UL MMY-MUP1441FT6P-UL MMY-MUP1681FT6P-UL MMY-MUP1441FT6P-UL MMY-MUP1681FT6P-UL MMY-MUP1681FT6P-UL Follower ----------------------------MMY-MUP0961FT6P-UL MMY-MUP0961FT6P-UL MMY-MUP0961FT6P-UL MMY-MUP0961FT6P-UL MMY-MUP1441FT6P-UL MMY-MUP1441FT6P-UL MMY-MUP1681FT6P-UL Table 5 Elite Heat Multi Module Heat Recovery Combinations 460V Model # MMY-UP144H1FT6P-UL MMY-UP192H1FT6P-UL MMY-UP240H1FT6P-UL MMY-UP288H1FT6P-UL MMY-UP360H1FT6P-UL Header MMY-MUP072H1FT6P-UL MMY-MUP096H1FT6P-UL MMY-MUP120H1FT6P-UL MMY-MUP096H1FT6P-UL MMY-MUP120H1FT6P-UL Combination Follower MMY-MUP072H1FT6P-UL MMY-MUP096H1FT6P-UL MMY-MUP120H1FT6P-UL MMY-MUP096H1FT6P-UL MMY-MUP120H1FT6P-UL Follower ------------MMY-MUP096H1FT6P-UL MMY-MUP072H1FT6P-UL ©2023 Carrier Confidential & Proprietary Not For Further Distribution 4 Product Bulletin Table 6 - Dimensional Comparison to e-Series Heat Recovery Notable Change (increase in height, weight and width) Improvement over Legacy (decrease in height, weight and width) MMYF (208-230V) u-Series (208-230V) MMYF-u LEGACY FAMILY CURRENT SKU Height (In) Width (In) MMY- MAP07 26FT9P- 72.9 39 UL MMY- MAP09 61FT9P- 72.9 47.6 UL MMY- MAP12 06FT9P- 72.9 47.6 UL MMY- MAP14 46FT9P- 72.9 63 UL MMY- MAP16 86FT9P- 72.9 63 UL Weight (Lbs) 600 721 721 882 882 2023 FAMILY 2023 SKU MMYMUP0721 FT9P-UL Height (In) 66.5 Width (In) 39.6 Weight (Lbs) 532 MMY- MUP0961 66.5 39.6 532 FT9P-UL MMY- MUP1201 66.5 51.4 675 FT9P-UL MMY- MUP1441 66.5 51.4 783 FT9P-UL MMY- MUP1681 66.5 51.4 783 FT9P-UL u-Series (208-230V) MMYF-u High Heat 2023 FAMILY 2023 SKU MMYMUP072H1F T9P-UL MMYMUP096H1F T9P-UL MMYMUP120H1F T9P-UL Height (In) 66.5 66.5 66.5 Width (In) Weight (Lbs) 51.4 532 51.4 783 51.4 783 LEGACY FAMILY CURRE NT SKU Heig ht (In) Widt Weigh h (In) t (Lbs) 2023 FAMILY 2023 SKU Heig ht (In) Widt Weigh h (In) t (Lbs) 2023 FAMIL Y 2023 SKU Height (In) Width (In) Weig ht (Lbs) MMY- MAP07 26FT6P- 72.9 39 615 UL MMY- MUP0721 66.5 39.6 552 FT6P-UL MMYMUP072H1F 66.5 T6P-UL 51.4 552 u-Series (460V) MMYF-u High Heat MMY- MAP09 66FT6P- 72.9 47.6 736 UL MMY- MUP0961 66.5 39.6 552 FT6P-UL MMYMUP096H1F 66.5 T6P-UL 51.4 776 MMYF u-Series (460V) MMYF-u MMY- MAP12 06FT6P- 72.9 47.6 736 UL MMY- MUP1201 66.5 51.4 686 FT6P-UL MMYMUP120H1F 66.5 T6P-UL 51.4 776 MMY- MAP14 46FT6P- 72.9 63 875 UL MMY- MUP1441 66.5 51.4 776 FT6P-UL MMY- MAP16 86FT6P- 72.9 63 875 UL MMY- MUP1681 66.5 51.4 776 FT6P-UL MMY- MUP1921 66.5 51.4 829 FT6P-UL ©2023 Carrier Confidential & Proprietary Not For Further Distribution 5 Product Bulletin Table 7 Electrical Comparison to e-Series Heat Recovery Note: Reduction to the Electrical Performance from Previous Model Notable Increase in Electrical Performance (MCA crosses over one of the following thresholds: 15, 20, 30 and any Breaker change) Minimum Circuit Amps determines the minimum main power wire size Max Breaker determines the maximum size of the over-current protection device (fuse or breaker) MMYF LEGACY FAMILY CURRENT SKU MMYMAP0726FT9P-UL MMYMAP0961FT9P-UL MMYMAP1206FT9P-UL MMYMAP1446FT9P-UL MMYMAP1686FT9P-UL MCA 23.3 34.2 45.4 52.1 66.2 MOCP 30 40 50 60 70 u-Series (208-230V) MMYF-u 2023 FAMILY 2023 SKU MMYMUP0721FT9P-UL MMYMUP0961FT9P-UL MMYMUP1201FT9P-UL MMYMUP1441FT9P-UL MMYMUP1681FT9P-UL u-Series (208-230V) MMYF-u High Heat MCA 36.4 36.6 36.8 MOCP 45 45 45 2023 FAMILY 2023 SKU MMYMUP072H1FT9P- UL MMYMUP096H1FT9P- UL MMYMUP120H1FT9P- UL MCA 36.6 52.3 53.1 51.5 60 57.4 80 MOCP 45 60 70 MMYF LEGACY FAMILY CURRENT SKU MMYMAP0726FT6P- UL MMYMAP0966FT6P- UL MMYMAP1206FT6P- UL MMYMAP1446FT6P- UL MMYMAP1686FT6P- UL MCA 11.8 17.0 22.0 23.4 29.7 Breaker 2023 FAMILY u-Series (460V) MMYF-u 15 20 25 30 35 2023 SKU MMYMUP0721FT6P-UL MMYMUP0961FT6P-UL MMYMUP1201FT6P-UL MMYMUP1441FT6P-UL MMYMUP1681FT6P-UL MMYMUP1921FT6P-UL u-Series (460V) MMYF-u High Heat MCA 17.4 17.5 21.3 MOCP 20 20 25 2023 FAMILY 2023 SKU MMYMUP072H1FT6P- UL MMYMUP096H1FT6P- UL MMYMUP120H1FT6P- UL 24.6 30 27.4 40 31.8 45 MCA 18.5 24.9 25.4 MOCP 25 30 30 (Note: MCA and MOCP were calculated per the new UL guidelines, which may cause MOCP values for the u-Series heat pumps may exceed that of the e-Series, in some cases) ©2023 Carrier Confidential & Proprietary Not For Further Distribution 6 Product Bulletin Table 8 Sound Data Comparison to e-Series Heat Recovery Notable Change (+2 dBA) Improvement over Legacy (-2 dBA) e-Series (208-230V) MMYF u-Series (208-230V) MMYF-u u-Series (208-230V) MMYF-u High Heat TIER LEGACY FAMILY CURRENT SKU Standard Rating (dBa) 2023 FAMILY 2023 SKU Standard Rating (dBa)* MMYMAP0726FT9P-UL 57 MMYMUP0721FT9P-UL 56 MMYMAP0961FT9P-UL 62 MMYMUP0961FT9P-UL 61 MMYMAP1206FT9P-UL 63 MMYMUP1201FT9P-UL 60 MMYMAP1446FT9P-UL 66.5 MMYMUP1441FT9P-UL 63 MMYMAP1686FT9P-UL 66.5 MMYMUP1681FT9P-UL 63 2023 FAMILY 2023 SKU MMYMUP072H1FT9P-UL MMYMUP096H1FT9P-UL MMYMUP120H1FT9P-UL Standard Rating (dBa)* 56 61 60 e-Series (460V) MMYF u-Series 460V) MMYF-u u-Series (460V) MMYF-u High Heat TIER LEGACY FAMILY CURRENT SKU Standard Rating (dBa) 2023 FAMILY 2023 SKU Standard Rating (dBa)* MMY- MAP0726FT6P-UL 57 MMY- MUP0721FT6P-UL 56 MMY- MAP0966FT6P-UL 62 MMY- MUP0961FT6P-UL 61 MMY- MAP1206FT6P-UL 63 MMY- MUP1201FT6P-UL 60 MMY- MAP1446FT6P-UL 66.5 MMY- MUP1441FT6P-UL 63 MMY- MAP1686FT6P-UL 66.5 MMY- MUP1681FT6P-UL 63 MMY- MUP1921FT6P-UL 64 2023 FAMILY 2023 SKU MMYMUP072H1FT6P-UL MMYMUP096H1FT6P-UL MMYMUP120H1FT6P-UL Standard Rating (dBa)* 56 61 60 ©2023 Carrier Confidential & Proprietary Not For Further Distribution 7 Product Bulletin Table 9 u-Series Heat Recovery 2021 AHRI Ratings (Note: Please use the AHRI website for M1 ratings of the u-Series heat recovery units) ©2023 Carrier Confidential & Proprietary Not For Further Distribution 8Microsoft Word for Microsoft 365