Specification Sheet

Durastar Heat Pump Mini Split Systems Cooling - DR1H12F12

PDF preview unavailable. Download the PDF instead.

durastar-dr1h12f12-specification-sheet
PROJECT NAME LOCATION ARCHITECT ENGINEER CONTRACTOR REFERENCE SUBMITTED BY

Indoor Unit (IDU): DRAS12F1B

12,000 BTU/H FLOOR MOUNTED IDU
SUBMITTAL COVER SHEET
DATE Wireless Remote Control

CAPACITIES Cooling Capacity (BTU/hr) Heating Capacity (BTU/hr)

Rated Rated

12000 12000

ELECTRICAL DATA Voltage/Phase/Frequency

208-230V, 1 Phase, 60 Hz

LINE SET REQUIREMENTS Connection Type Liquid Gas Drain Port O.D. / Drain Hose I.D.

Flare Ø1/4" (Ø6.35mm) Ø1/2" (Ø12.7mm) Ø5/8" (Ø16mm)

INDOOR UNIT FAN DATA Low

Air Flow (CFM)

Medium High

Type

DC

RLA

1.0

Low

Sound Pressure (dB(A))

Medium High

Specifications are subject to change without notice. © 2022 Ferguson Enterprises LLC www.durastar.com

248 316 365
34.5 43 45

INDOOR UNIT DIMENSIONS

Width

Unit Dimensions

Depth

Height

Width

Carton Dimensions

Depth

Height

Net Weight

32.6 lbs.

Gross Weight

41.0 lbs.

27 9/16" 8 1/4" 23 5/8" 30 11/16" 11 13/16" 27"

PRODUCT FEATURES · Wireless Remote Control with "Follow Me" Technology · Auto Restart · Auto Changeover · 24-hour Timer · Self Clean Function

1

Form No. V1.0_03.22

27 9/16"

12,000 BTU/H FLOOR MOUNTED IDU
DIMENSIONS - DRAS12F1A
8 1/4"

23 5/8"

3 11/16" (94mm)

11 1/4" (285mm)

6 13/16" (173mm)

Mounting plate (some units)

7 11/16" (195mm)
Mounting brackets (some units)

Specifications are subject to change without notice.

© 2022 Ferguson Enterprises LLC

www.durastar.com

2

Form No. V1.0_03.22

PROJECT NAME LOCATION ARCHITECT ENGINEER CONTRACTOR REFERENCE SUBMITTED BY
Indoor Unit (IDU): DRAW12F1B

12,000 BTU/H WALL MOUNTED HEAT PUMP SYSTEM
SUBMITTAL COVER SHEET

DATE
Outdoor Unit (ODU): DRA1U12S1B

Wireless Remote Control

PRODUCT FEATURES · Wireless Remote Control with "Follow Me" Technology · Variable Speed Inverter Compressor · Auto Restart · Sleep Mode · Turbo Mode · 24-Hour Timer Feature · Quiet operation · 46oF Freeze Protection · Low ambient heating down to -13 oF · Low ambient cooling down to 5 oF · Included base pan heater · Refrigerant leak detection · Anti-corrosive fin coating

CAPACITIES Cooling Capacity (BTU/hr)

Rated at 95 oF Sensible at 5 oF3 Minimum Maximum Rated at 47 oF

12000 8630 3600 13300 12000

SYSTEM DATA Refrigerant Type Refrigerant Charge (oz.) Design Pressure (PSIG) Indoor/ Oudoor Coil Coating
EFFICIENCY DATA SEER2 EER2 HSPF2 SEER EER HSPF COP at 47 oF COP at 5 oF

Heating Capacity (BTU/hr)

Maximum at 5 oF4 Minimum

9500 4500

Maximum

13500

Specifications are subject to change without notice.

© 2022 Ferguson Enterprises LLC

www.durastar.com

1

R-410A 38.1
550/340 Golden Fin Coating
23.1 13.0 10.8 22.2 13.0 11.0 3.40 1.80
Form No. V1.0_10.22

12,000 BTU/H WALL MOUNTED HEAT PUMP SYSTEM
SPECIFICATIONS

LINE SET REQUIREMENTS Connection Type Liquid Gas Pre-Charge Length Minimum Length Maximum Length Maximum Height Differential Additional Refrigerant (oz./ft)

Flare Ø1/4" (Ø6.35mm) Ø1/2" (Ø12.7mm)
25' 10' 82' 33' 0.16

OUTDOOR UNIT

Width

30 1/8"

Unit Dimensions

Depth

11 15/16"

Height

21 7/8"

Width

34 15/16"

Carton Dimensions

Depth

13 1/4"

Height

24"

Net Weight

63.7 lbs.

Gross Weight

69.0 lbs.

Cooling Operating Temperature

5 °F - 122 °F

Heating Operating Temperature

-13 °F - 75 °F

Voltage/Phase/Frequency

208-230V, 1 Phase, 60 Hz

Voltage Range

187-253V

Recommended Breaker (Amps)

15

Minimum Circuit Ampacity (Amps)

13

Communication Wire Size

14*4 AWG Stranded

Rated Current - Cooling (Amps)1

4.05

Rated Current - Heating (Amps)2

4.5

Sound Pressure (dB(A))

53.5

INDOOR UNIT Unit Dimensions
Carton Dimensions

Width Depth Height Width Depth Height

31 9/16" 7 7/8" 11 5/8" 34 7/16" 11 1/4" 14 15/16"

Net Weight Gross Weight
Indoor Unit Air Flow (CFM)
Moisture Removal (Pints/day) Drain Port O.D. Recommended Breaker (Amps)

18.7 lbs.

24.3 lbs.

Low

153

Medium

194

High

291

78.24

Ø5/8" (Ø16mm) 15

Low

25

Sound Pressure (dB(A))

Medium

36

High

42

COMPRESSOR Type Oil Type Oil Charge (oz.)

DC Rotary Inverter Ester Oil VG74 10.5 (310 ml)

1 Measured at 95 °F. 2 Measured at 47 °F. 3 Sensible Capacity: Indoor 80 °F DB, 67 °F WB // Outdoor 5 °F DB, 4 °F WB 4 Maximum Capacity: Indoor 70 °F DB, 67 °F WB // Outdoor 5 °F DB, 4 °F WB

Specifications are subject to change without notice.

© 2022 Ferguson Enterprises LLC

www.durastar.com

2

Form No. V1.0_10.22

Unit Dimensions

12,000 BTU/H WALL MOUNTED HEAT PUMP SYSTEM
IDU DIMENSIONS - DRAW12F1B

31 9/16" (802mm)

7 7/8" (200mm)

11 5/8" (295mm)

Mounting Plate Dimensions
9 1/16" (230mm) 7 1/2" (190mm)

15 7/8" (403mm) 9 1/16" (231mm)

4 3/4" (121mm)

1 7/16" (36mm)

11 5/8" (295mm)
1 7/8" (47mm)
Left rear wall hole 2 9/16" (65mm)
Clearance Distances

31 11/16" (805mm)
6" (15cm) or more

2 1/16" (53mm)
Right rear wall hole 2 9/16" (65mm)

4 3/4" (12cm) or more

4 3/4" (12cm) or more

Specifications are subject to change without notice. © 2022 Ferguson Enterprises LLC www.durastar.com

6' (1.83m) or more
3

Form No. V1.0_10.22

12,000 BTU/H WALL MOUNTED HEAT PUMP SYSTEM
ODU DIMENSIONS - DRA1U12S1B
Clearances

24" (610mm) above

12o" n(3l0e5ftmm)

1f2ro"m(30b5amckmw)all

79" (2in0f0ro7mntm)

Dimensions
32 7/8" (835mm) 30 1/8" (765mm)

24o"n(r6ig10hmt m)

21 7/8" (555mm)

11 15/16" (303mm)

17 13/16" (452mm)

11 1/4" (286mm)

NOTE Illustrations in this document are for explanatory purposes. The actual shape of your mini-split equipment may vary slightly.

Specifications are subject to change without notice.

© 2022 Ferguson Enterprises LLC

www.durastar.com

4

Form No. V1.0_10.22

