Durastar Heat Pump Mini Split Systems Cooling - DR1H12F12
PROJECT NAME LOCATION ARCHITECT ENGINEER CONTRACTOR REFERENCE SUBMITTED BY Indoor Unit (IDU): DRAS12F1B 12,000 BTU/H FLOOR MOUNTED IDU SUBMITTAL COVER SHEET DATE Wireless Remote Control CAPACITIES Cooling Capacity (BTU/hr) Heating Capacity (BTU/hr) Rated Rated 12000 12000 ELECTRICAL DATA Voltage/Phase/Frequency 208-230V, 1 Phase, 60 Hz LINE SET REQUIREMENTS Connection Type Liquid Gas Drain Port O.D. / Drain Hose I.D. Flare Ø1/4" (Ø6.35mm) Ø1/2" (Ø12.7mm) Ø5/8" (Ø16mm) INDOOR UNIT FAN DATA Low Air Flow (CFM) Medium High Type DC RLA 1.0 Low Sound Pressure (dB(A)) Medium High Specifications are subject to change without notice. © 2022 Ferguson Enterprises LLC www.durastar.com 248 316 365 34.5 43 45 INDOOR UNIT DIMENSIONS Width Unit Dimensions Depth Height Width Carton Dimensions Depth Height Net Weight 32.6 lbs. Gross Weight 41.0 lbs. 27 9/16" 8 1/4" 23 5/8" 30 11/16" 11 13/16" 27" PRODUCT FEATURES · Wireless Remote Control with "Follow Me" Technology · Auto Restart · Auto Changeover · 24-hour Timer · Self Clean Function 1 Form No. V1.0_03.22 27 9/16" 12,000 BTU/H FLOOR MOUNTED IDU DIMENSIONS - DRAS12F1A 8 1/4" 23 5/8" 3 11/16" (94mm) 11 1/4" (285mm) 6 13/16" (173mm) Mounting plate (some units) 7 11/16" (195mm) Mounting brackets (some units) Specifications are subject to change without notice. © 2022 Ferguson Enterprises LLC www.durastar.com 2 Form No. V1.0_03.22 PROJECT NAME LOCATION ARCHITECT ENGINEER CONTRACTOR REFERENCE SUBMITTED BY Indoor Unit (IDU): DRAW12F1B 12,000 BTU/H WALL MOUNTED HEAT PUMP SYSTEM SUBMITTAL COVER SHEET DATE Outdoor Unit (ODU): DRA1U12S1B Wireless Remote Control PRODUCT FEATURES · Wireless Remote Control with "Follow Me" Technology · Variable Speed Inverter Compressor · Auto Restart · Sleep Mode · Turbo Mode · 24-Hour Timer Feature · Quiet operation · 46oF Freeze Protection · Low ambient heating down to -13 oF · Low ambient cooling down to 5 oF · Included base pan heater · Refrigerant leak detection · Anti-corrosive fin coating CAPACITIES Cooling Capacity (BTU/hr) Rated at 95 oF Sensible at 5 oF3 Minimum Maximum Rated at 47 oF 12000 8630 3600 13300 12000 SYSTEM DATA Refrigerant Type Refrigerant Charge (oz.) Design Pressure (PSIG) Indoor/ Oudoor Coil Coating EFFICIENCY DATA SEER2 EER2 HSPF2 SEER EER HSPF COP at 47 oF COP at 5 oF Heating Capacity (BTU/hr) Maximum at 5 oF4 Minimum 9500 4500 Maximum 13500 Specifications are subject to change without notice. © 2022 Ferguson Enterprises LLC www.durastar.com 1 R-410A 38.1 550/340 Golden Fin Coating 23.1 13.0 10.8 22.2 13.0 11.0 3.40 1.80 Form No. V1.0_10.22 12,000 BTU/H WALL MOUNTED HEAT PUMP SYSTEM SPECIFICATIONS LINE SET REQUIREMENTS Connection Type Liquid Gas Pre-Charge Length Minimum Length Maximum Length Maximum Height Differential Additional Refrigerant (oz./ft) Flare Ø1/4" (Ø6.35mm) Ø1/2" (Ø12.7mm) 25' 10' 82' 33' 0.16 OUTDOOR UNIT Width 30 1/8" Unit Dimensions Depth 11 15/16" Height 21 7/8" Width 34 15/16" Carton Dimensions Depth 13 1/4" Height 24" Net Weight 63.7 lbs. Gross Weight 69.0 lbs. Cooling Operating Temperature 5 °F - 122 °F Heating Operating Temperature -13 °F - 75 °F Voltage/Phase/Frequency 208-230V, 1 Phase, 60 Hz Voltage Range 187-253V Recommended Breaker (Amps) 15 Minimum Circuit Ampacity (Amps) 13 Communication Wire Size 14*4 AWG Stranded Rated Current - Cooling (Amps)1 4.05 Rated Current - Heating (Amps)2 4.5 Sound Pressure (dB(A)) 53.5 INDOOR UNIT Unit Dimensions Carton Dimensions Width Depth Height Width Depth Height 31 9/16" 7 7/8" 11 5/8" 34 7/16" 11 1/4" 14 15/16" Net Weight Gross Weight Indoor Unit Air Flow (CFM) Moisture Removal (Pints/day) Drain Port O.D. Recommended Breaker (Amps) 18.7 lbs. 24.3 lbs. Low 153 Medium 194 High 291 78.24 Ø5/8" (Ø16mm) 15 Low 25 Sound Pressure (dB(A)) Medium 36 High 42 COMPRESSOR Type Oil Type Oil Charge (oz.) DC Rotary Inverter Ester Oil VG74 10.5 (310 ml) 1 Measured at 95 °F. 2 Measured at 47 °F. 3 Sensible Capacity: Indoor 80 °F DB, 67 °F WB // Outdoor 5 °F DB, 4 °F WB 4 Maximum Capacity: Indoor 70 °F DB, 67 °F WB // Outdoor 5 °F DB, 4 °F WB Specifications are subject to change without notice. © 2022 Ferguson Enterprises LLC www.durastar.com 2 Form No. V1.0_10.22 Unit Dimensions 12,000 BTU/H WALL MOUNTED HEAT PUMP SYSTEM IDU DIMENSIONS - DRAW12F1B 31 9/16" (802mm) 7 7/8" (200mm) 11 5/8" (295mm) Mounting Plate Dimensions 9 1/16" (230mm) 7 1/2" (190mm) 15 7/8" (403mm) 9 1/16" (231mm) 4 3/4" (121mm) 1 7/16" (36mm) 11 5/8" (295mm) 1 7/8" (47mm) Left rear wall hole 2 9/16" (65mm) Clearance Distances 31 11/16" (805mm) 6" (15cm) or more 2 1/16" (53mm) Right rear wall hole 2 9/16" (65mm) 4 3/4" (12cm) or more 4 3/4" (12cm) or more Specifications are subject to change without notice. © 2022 Ferguson Enterprises LLC www.durastar.com 6' (1.83m) or more 3 Form No. V1.0_10.22 12,000 BTU/H WALL MOUNTED HEAT PUMP SYSTEM ODU DIMENSIONS - DRA1U12S1B Clearances 24" (610mm) above 12o" n(3l0e5ftmm) 1f2ro"m(30b5amckmw)all 79" (2in0f0ro7mntm) Dimensions 32 7/8" (835mm) 30 1/8" (765mm) 24o"n(r6ig10hmt m) 21 7/8" (555mm) 11 15/16" (303mm) 17 13/16" (452mm) 11 1/4" (286mm) NOTE Illustrations in this document are for explanatory purposes. The actual shape of your mini-split equipment may vary slightly. Specifications are subject to change without notice. © 2022 Ferguson Enterprises LLC www.durastar.com 4 Form No. V1.0_10.22PyPDF2