[PDF] T500 | ELECTROLYTIC TILTMETER

THE T500 TILTMETER IS AN. ELECTROLYTIC FLUID-BASED. TILT SENSOR THAT CAN BE. USED FOR PRECISION ROTATION. MEASUREMENTS, GENERALLY OVER.

PDF preview unavailable. Download the PDF instead.

?sdm process download=1&download id=27983
SENSORS

T500 | ELECTROLYTIC TILTMETER

THE T500 TILTMETER IS AN ELECTROLYTIC FLUID-BASED TILT SENSOR THAT CAN BE USED FOR PRECISION ROTATION MEASUREMENTS, GENERALLY OVER A SHORT PERIOD OF TIME. THESE UNITS CONNECT DIRECTLY TO OUR STRUCTURAL TESTING SYSTEM, STRUCTURAL MONITORING SYSTEMS, AND ARE ALSO COMPATIBLE WITH MOST GENERIC DATA ACQUISITION SYSTEMS. THE RUGGED ALUMINUM HOUSINGS PROVIDE BOTH EASY MOUNTING AND MECHANICAL ZEROADJUSTMENT CAPABILITY.

FEATURES
++ Simple & quick range adjustment ++ Mounting tabs for adhesive application ++ Measurement range from ±0.5° to ±60° ++ 4 mounting configurations ++ Designed to exceed IP67 ++ High accuracy ++ Sub-arc second resolution ++ Internal signal conditioning ++ Overload protection
DIMENSIONS

APPLICATIONS
++ Rotation in bridge slabs, beams, and piers due to live load
++ Retaining wall or abutment movement during construction
++ Rotation angle of tainter gates during operation

740 S PIERCE AVE UNIT 15 LOUISVILLE, CO 80027

+1.303.494.3230 sales@bditest.com

SPECIFICATIONS

MODEL

T500-005

T500-030

T500-100

LINEAR RANGE (ARC DEGREES)

±0.5

±3

±10

TOTAL RANGE (ARC DEGREES)

±1

±6

±15

OUTPUT (MV/ARC SECOND)

1

0.4

-

OUTPUT (MV/ARC DEGREE)

-

-

420

RESOLUTION (ARC DEGREES)

< 0.0001

< 0.0003

< 0.0005

NULL REPEATABILITY (ARC DEGREES)

< 0.0008

< 0.0008

< 0.001

SYMMETRY @ 1/2 LINEAR SCALE (%)

< 2

< 2

< 2

ACCURACY @ 1/2 LINEAR SCALE (%FS)

-

< 2

< 2

ACCURACY @ FULL SCALE (%FS)

-

< 8

< 5

NULL IMPEDANCE (KOHMS) +/-20%

1

12

40

NULL STABILITY, 12 HRS @ 25 DEG. C (ARC DEG'S, TYP.)

< 0.005

< 0.005

< 0.001

SETTLEMENT TIME (SECONDS)

~1.1

~1.2

~0.75

EXCITATION VOLTAGE

+5 to +15 Vdc

POWER RATING MAX TYPICAL INTELLIDUCER1
INPUT IMPEDANCE

75 mW 2.5 mW @ +5.0 Vdc 13 mW @ +5.0 Vdc 5 M

OUTPUT

±2 Vdc

OPERATING TEMPERATURE

-13 °F to 158 °F (-25 °C to 70 °C)

STORAGE TEMPERATURE

-40 °F to 176 °F (-40 °C to 80 °C)

TEMP. COEFFICIENT OF SCALE (%/°C, TYP.)

0.6

0.6

0.1

CABLE HOUSING

Custom lead cable length made to order: IC-02-187 [22 AWG, 2 shielded pair, drain wire, red PVC jacket] IC-02-250 [22 AWG, 2 shielded pair, drain wire, blue PVC jacket] IC-03-250 [24 AWG, 3 shielded pair, drain wire, black PVC jacket] Machined 6061-Aluminum

CORROSION PROTECTION

Hard Anodized Clear (MIL-A-8625 Type III)

WEATHER PROOFING

Designed to exceed IP67

DIMENSIONS

4.25 x 2.6 x 3 (108 x 66 x 76 mm)

WEIGHT

1.2 lb (544 g)

MOUNTING

Through holes for ¼ in (M6) bolts or anchors on five sides Reusable mounting tabs (gluing/welding)

1 Intelliducer connector required with STS4 Intelliducer data acquisition nodes.

T500-600 ±60 ±80 160
< 0.001 < 0.02
< 2 < 0.8 < 3
8 < 0.005
~1.0
0.1

Available on:

GS07F197CA

OPTIONS & ACCESSORIES
Intelliducer Connector ­ Required for use with STS Intelliducer Nodes, cable is connected and potted for a weatherproof seal.
Integrated Thermistor ­ Temperature range of -55 °C to +220 °C, ±0.5 °C accuracy.

Reusable Mounting Tabs ­ ¼-20 or M6, zinc plated steel mounting tab.
Protective Covers ­ Insulated aluminum protective covers

BDITEST.COM

©2019 BDI, All Rights Reserved | Doc. 201541 | Rev. A

