Guangzhou Netum Electronic Technology Co., Ltd NT-1203 Wireless Barcode Scanner 2AI87-NT-1203 2AI87NT1203 nt 1203
TEST REPORT FCC ID: 2AI87-NT-1203 For Guangzhou Netum Electronic Technology Co., Ltd Wireless Barcode Scanner Model No. Trade Name Prepared for Address Prepared by Address : NT-1203, 1205, 1206, 1209, 2018, 6800, 6900, 9600, 2028, H2, H3, R1, R2, Z1, Z2, Z3, G2, M2, RD1908, 200, 300, 6870W, 6860W,1900 : N/A : Guangzhou Netum Electronic Technology Co., Ltd Unit137, the Pacific Industry Area, Xintang Town, Zengcheng District, Guangzh : ou, China : Shenzhen Alpha Product Testing Co., Ltd. Building B, East Area of Nanchang Second, Industrial Zone, Gushu 2nd Road, : Bao'an, Shenzhen, China Report No. : T1860532 01 Date of Receipt : July 14, 2016 Date of Test : July 14-25, 2016 Date of Report : July 26, 2016 Version Number : REV0 Page 2 of 36 Report No.: T1860532 01 Contents 1. General Information............................................................................................................... 4 1.1. Description of Device (EUT) ...............................................................................4 1.2. Accessories of device (EUT) ...............................................................................5 1.3. Test Lab information ............................................................................................5 2. Summary of test ...................................................................................................................... 6 2.1. Summary of test result .........................................................................................6 2.2. Assistant equipment used for test.........................................................................6 2.3. Block Diagram .....................................................................................................7 2.4. Test mode .............................................................................................................7 2.5. Test Conditions.....................................................................................................8 2.6. Measurement Uncertainty (95% confidence levels, k=2) ....................................8 2.7. Test Equipment.....................................................................................................9 3. Radiation Emission ............................................................................................................... 10 3.1. Radiation Emission Limits(15.209&231) ..........................................................10 3.2. Test Setup ...........................................................................................................10 3.3. Test Procedure ....................................................................................................12 3.4. Test Equipment Setting For emission test. .........................................................13 3.5. Test Condition ....................................................................................................13 3.6. Test Result ..........................................................................................................13 4. POWER LINE CONDUCTED EMISSION ....................................................................... 17 4.1. Conducted Emission Limits (15.209) ................................................................17 4.2. Test Setup ...........................................................................................................17 4.3. Test Procedure ....................................................................................................18 4.4. Test Results ........................................................................................................18 5. Occupied bandwidth............................................................................................................. 21 5.1. Test limit.............................................................................................................21 5.2. Method of measurement.....................................................................................21 5.3. Test Setup ...........................................................................................................21 5.4. Test Results ........................................................................................................21 6. Transmission time................................................................................................................. 23 6.1. Test limit.............................................................................................................23 6.2. Method of measurement.....................................................................................23 6.3. Test Setup ...........................................................................................................23 6.4. Test Results ........................................................................................................24 7. Antenna Requirement .......................................................................................................... 26 7.1. Standard Requirement ........................................................................................26 7.2. Antenna Connected Construction ......................................................................26 7.3. Result..................................................................................................................26 8. Test setup photo .................................................................................................................... 27 9. Photos of EUT ....................................................................................................................... 29 Page 3 of 36 Report No.: T1860532 01 Applicant Manufacturer Product DECLARATION : Guangzhou Netum Electronic Technology Co., Ltd : Guangzhou Netum Electronic Technology Co., Ltd : Wireless Barcode Scanner (A) Model No. NT-1203, 1205, 1206, 1209, 2018, 6800, 6900, 9600, : 2028, H2, H3, R1, R2, Z1, Z2, Z3, G2, M2, RD1908, 200, 300, 6870W, 6860W,1900 (B) Trade Name : N/A (C) Power supply : DC 3.7V From Battery, DC 5V From Base for charge Measurement Standard Used: FCC Rules and Regulations Part 15 Subpart C Section 15.231: 2015, ANSI C63.4:2014 ANSI C63.10:2013 The device described above is tested by Shenzhen Alpha Product Testing Co., Ltd. to determine the maximum emission levels emanating from the device. The maximum emission levels are compared to the FCC Part 15 Subpart C limits both conducted and radiated emissions. The test results are contained in this test report and Shenzhen Alpha Product Testing Co., Ltd. is assumed of full responsibility for the accuracy and completeness of these tests. After the test, our opinion is that EUT compliance with the requirement of the above standards. This report applies to above tested sample only. This report shall not be reproduced in parts without written approval of Shenzhen Alpha Product Testing Co., Ltd. Tested by (name + signature).............: Reak Yang Test Engineer ..................................... Approved by (name + signature).......: Simple Guan .................................... Project Manager Date of issue...... .......................: July 26, 2016 1. General Information 1.1. Description of Device (EUT) EUT : Wireless Barcode Scanner Model No. DIFF. : NT-1203, 1205, 1206, 1209, 2018, 6800, 6900, 9600, 2028, H2, H3, R1, R2, Z1, Z2, Z3, G2, M2, RD1908, 200, 300, 6870W, 6860W,1900 : Only Differ in model name Trade mark : N/A Power supply : DC 3.7V From Battery, DC 5V From Base for charge Operation frequency Channel : 443333..77991MMHHzz : 1 Modulation : GFSK Antenna Type : Internal antenna, max gain 0dBi. Applicant : Guangzhou Netum Electronic Technology Co., Ltd Address : Unit137, the Pacific Industry Area, Xintang Town, Zengcheng District, G uangzhou, China Manufacturer Guangzhou Netum Electronic Technology Co., Ltd Address Unit137, the Pacific Industry Area, Xintang Town, Zengcheng District, G uangzhou, China 1.2. Accessories of device (EUT) Accessories Model Input Output Accessories2 Model : N/A : N/A : N/A : N/A : N/A : N/A 1.3. Test Lab information Shenzhen Alpha Product Testing Co., Ltd. Building B, East Area of Nanchang Second, Industrial Zone, Gushu 2nd Road, Bao'an, Shenzhen, China March 25, 2015 File on Federal Communication Commission Registration Number: 203110 July 18, 2014 Certificated by IC Registration Number: 12135A 2. Summary of test 2.1. Summary of test result Description of Test Item Spurious Emission Standard Section 15.231&15.209 Results PASS Conduction Emission Section 15.207 PASS Occupied bandwidth Section 15.231 PASS Transmission time Section 15.231 PASS Band Edge Section 15.231 N/A Antenna Requirement Section 15.203 PASS Duty cycle Section 15.231&15.35 PASS Note Test according to ANSI C63.4-2014 and ANSI C63.10-2013 2.2. Assistant equipment used for test Description1 : Notebook Manufacturer : ACER Model No. : ZQR Remark: FCC DOC approved Description2 : Scanner Base Manufacturer : FARSUN Model No. : FS-WX2800 Remark: FCC DOC approved 2.3. Block Diagram 1. For radiated emissions test: EUT was placed on a turn table, which is 0.8 meter high above ground. EUT was set into test mode before test. New battery is used during all test Notebook BASE EUT 2.4. Test mode EUT work in Continuous TX mode, and select test channel, wireless mode Tested mode, channel, and data rate information Mode Channel Frequency (MHz) GFSK CH1 433.79 Channel ... Frequency (MHz) ... 2.5. Test Conditions Temperature range Humidity range Pressure range 21-25 40-75% 86-106kPa 2.6. Measurement Uncertainty (95% confidence levels, k=2) Item Uncertainty for Power point Conducted Emissions Test Uncertainty for Radiation Emission test in 3m chamber (30MHz to 1GHz) Uncertainty for Radiation Emission test in 3m chamber (1GHz to 25GHz) Uncertainty for conducted RF Power MU 2.71dB 3.90 dB 3.92dB 4.26 dB 4.28 dB 0.16dB Remark Polarize: V Polarize: H Polarize: H Polarize: V 2.7. Test Equipment Equipment 3m Semi-Anechoic Spectrum analyzer Manufacture CHENYU Agilent Model No. N/A Serial No. N/A CLaalsDt ucael. Cal Interval Due to 2018.01.18 2Year E4407B MY46185649 2017.01.16 1Year Receiver R&S ESPI 101873 2017.01.16 1Year Receiver R&S ESCI 101165 2017.01.16 1Year Bilog Antenna SCHWARZBECK VULB 9168 VULB9168-438 2018.01.18 Horn Antenna L.I.S.N.#1 BBHA 9120 SCHWARZBECK BBHA 9120 D D(1201) Schwarzbeck NSLK8126 8126466 2017.01.20 2017.01.16 2Year 2Year 1 Year L.I.S.N.#2 Cable ROHDE&SCHWA RZ Resenberger ENV216 N/A 101043 2017.01.16 1 Year No.1 2017.01.16 1Year Cable SCHWARZBECK N/A No.2 2017.01.16 1Year Cable SCHWARZBECK N/A No.3 2017.01.16 1Year Pre-amplifier HP HP8347A 2834A00455 2017.01.18 1Year Pre-amplifier vector Signal Generator vector Signal Generator X-series USB Peak and Average Power Sensor X-series USB Peak and Average Power Sensor Signal Analyzer Agilent Agilent Agilent Agilent Agilent Agilent 8449B 3008A02664 2017.01.18 1Year N5182A MY49060042 2016.11.16 1 Year E4438C US44271917 2016.11.16 1 Year U2021XA MY54080020 2016.11.16 1 Year U2021XA MY54110001 2016.11.16 1 Year N9020A MY48030494 2016.11.16 1 Year Remark: 1 For the relevant Conducted Measurement, the temporary antenna connector is used during the measurement. Antenna Connector Impedance: 50 , Cable Loss: 1.0 dB 3. Radiation Emission 3.1. Radiation Emission Limits(15.209&231e) Carrier 433.79MHz dB7u2V.7/m(A@V3m) 3 frequency 72.8(AV) 3 m Carrier d9B2uV.7/m(P@K3)m 3 433.79MHz frequency 92.8(PK) 3 m NOTE: a) The tighter limit applies at the band edges. b) Emission Level(dB uV/m)=20log Emission Level(Uv/m) 3.2. Test Setup See the next page. Below 30MHz Test Setup Above 30MHz Test Setup 1.5m Above 1GHz Test Setup 3.3. Test Procedure a) The measureing distance of 3m shall be used for measurements at frequency up to 1GHz and above 1GHz, The EUT was placed on a rotating 0.8 m high above ground,The table was rotated 360 degrees to determine the position of the highest radiation b) The Test antenna shall vary between 1m and 4m,Both Horizontal and Vertical antenna are set ot make measurement. c) The initial step in collecting conducted emission data is a spectrum analyzer Peak detector mode pre-scanning the measurement frequency range. Significent Peaks are then marked. and then Qusia Peak Detector mode remeasured d) If Peak value comply with QP limit Below 1GHz.The EUT deemed to comply with QP limit. But the Peak value and average value both need to comply with applicable limit above 1GHz. e) For the actual test configuration, please see the test setup photo. 3.4. Test Equipment Setting For emission test. 9KHz~150KHz 150KHz~30MHz 30MHz~1GHz Above 1GHz RBW 200Hz RBW 9KHz RBW 120KHz RBW 1MHz VBW1KHz VBW 30KHz VBW 300KHz VBW 3MHz 3.5. Test Condition Continual Transmitting in maximum power(The new battery be used during Test) 3.6. Test Result We have scanned the 10th harmonic from 9KHz to the EUT. Detailed information please see the following page. From 9KHz to 30MHz: Conclusion: PASS Note: The amplitude of spurious emissions which are attenuated by more than 20dB below the permissible value has no need to be reported. Notes: 1 --Means other frequency and mode comply with standard requirements and at least have 20dB margin. Correct Factor=Cable Loss+Antenna Factor-Amplifier Gain Measurement Result=Reading + Correct Factor Margin=Measurement Result-Limit 2 Spectrum setting: a. Peak setting 30MHz-1GHz, RBW=100KHz, VBW=300KHz. 3- PK measure result values is less than the AVG limit values, so AV measure result values test not applicable. Radiated Emissions Result of Inside band above 1GHz EUT Temperature Wireless Barcode Scanner 25oC Pressure 960hPa Test Mode TX CH1 Model Name NT-1203 Relative Humidity 56% Test voltage DC 3.7V From Battery Test by Reak Freq. Ant. Pol Peak (MHz) H/V Reading (dBuV) 1291.5 V 1301.37 V 53.48 52.74 Above 1GHz AV Ant. / CL Reading CF (dBuV) (dB) --- -10.83 --- -10.83 Actual Fs Peak (dBuV/m) 42.65 41.41 Peak Limit (dBuV/m) 74.00 74.00 Margin (dB) Remark -31.35 Peak -32.59 Peak 1291.5 H 1301.37 H 51.61 50.90 --- -10.83 --- -10.83 40.78 40.07 74.00 -33.22 Peak 74.00 -33.93 Peak 4. POWER LINE CONDUCTED EMISSION 4.1. Conducted Emission Limits (15.209) Frequency MHz 0.15 -0.50 0.50 -5.00 5.00 -30.00 Limits dB(V) Quasi-peak Level Average Level 66 -56* 56 60 56 - 46* 46 50 Notes: 1. *Decreasing linearly with logarithm of frequency. 2. The lower limit shall apply at the transition frequencies. 3.The limit decreases in line with the logarithm of the frequency in the rang of 0.15 to 0.50 MHz. 4.2. Test Setup 4.3. Test Procedure The EUT is put on the plane 0.8m high above the ground by insulating support and is connected to the power mains through a line impedance stabilization network (L.I.S.N.). This provides a 50ohm coupling impedance for the EUT system. Please refer the block diagram of the test setup and photographs. Both sides of AC lines are checked to find out the maximum conducted emission. In order to find the maximum emission levels, the relative positions of equipment and all of the interface cables shall be changed according to ANSI C63.4-2014 on Conducted Emission Measurement. The bandwidth of test receiver (R & S ESCS30) is set at 9 kHz. 4.4. Test Results Conclusion: PASS Detailed information please see the following page. 5. Occupied bandwidth 5.1. Test limit Please refer section15.231 According to§15.231(C), The bandwidth of the emission shall be no wider than 0.25% of the center frequency for devices operating above 70MHz and below 900MHz. 5.2. Method of measurement a)The bandwidth is measured at an amplitude level reduced 20dB from the reference level. The reference level is the level of the highest amplitude signal observed from the transmitter at the fundamental frequency. Once the reference level is established, the equipment is conditioned with typical modulating signal to produce the worst-case (i.e. the widest) bandwidth. b)The test receiver RBW set 30KHz,VBW set 30KHz,Sweep time set auto. 5.3. Test Setup EUT Spectrum Analyzer 5.4. Test Results EUT: Wireless Barcode Scanner M/N: NT-1203 Test Mode: Keeping TX mode Test date: 2016-07-22 Test site: RF site Tested by: Reak Mode Freq 20dB Bandwidth (KHz) (MHz) Limit (kHz) GFSK 433.79 14.34 1084.5 Conclusion PASS 6. Transmission time 6.1. Test limit Please refer section15.231(e) According to §15.231(e), In addition, devices operated under the provisions of this paragraph shall be provided with a means for automatically limiting operation so that the duration of each transmission shall not be greater than one second and the silent period between transmissions shall be at least 30 times the duration of the transmission but in no case less than 10 seconds. 6.2. Method of measurement 6.2.1. Place the EUT on the table and set it in transmitting mode. 6.2.2. Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port to the spectrum analyzer. 6.2.3. Set spectrum analyzer Span = 0MHz, Sweep = 200ms. 6.2.4. Set the spectrum analyzer as RBW, VBW=1MHz, 6.2.5. Max hold, view and count how many channel in the band. 6.3. Test Setup EUT Spectrum Analyzer 6.4. Test Results EUT: Wireless Barcode Scanner M/N: NT-1203 Test Mode: Keeping TX mode Test date: 2016-07-22 Test site: RF site Mode Freq (MHz) Test Result(S) GFSK 433.79 0.3 Tested by: Reak Limit (S) <1S Conclusion PASS EUT: Wireless Barcode Scanner M/N: NT-1203 Test Mode: Keeping TX mode Test date: 2016-07-22 Test site: RF site Tested by: Reak Mode Freq (MHz) Silent Period(S) Limit (S) Conclusion GFSK 433.79 10.92 >10S PASS Note: According OP, EUT interval 11S transmitter a time, compliance with 15.231e section. 7. Antenna Requirement 7.1. Standard Requirement An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this Section. The manufacturer may design the unit so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector is prohibited. 7.2. Antenna Connected Construction The directional gains of antenna used for transmitting is 0dBi, and the antenna connector is de- signed with permanent attachment and no consideration of replacement. Please see EUT photo for details. 7.3. Result The EUT antenna is Integrated antenna. It comply with the standard requirement. 8. Test setup photo Photos of Radiated emission Photos of Power Line Conducted Emission 9. Photos of EUT ---------END OF THE REPORT-------Acrobat Distiller 9.0.0 (Windows)