1

Yu

Test report

Guangzhou Netum Electronic Technology Co., Ltd NT-1203 Wireless Barcode Scanner 2AI87-NT-1203 2AI87NT1203 nt 1203

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=3100754
TEST REPORT
FCC ID: 2AI87-NT-1203
For
Guangzhou Netum Electronic Technology Co., Ltd Wireless Barcode Scanner

Model No.
Trade Name Prepared for Address
Prepared by Address

: NT-1203, 1205, 1206, 1209, 2018, 6800, 6900, 9600, 2028, H2, H3, R1, R2, Z1, Z2, Z3, G2, M2, RD1908, 200, 300, 6870W, 6860W,1900
: N/A
: Guangzhou Netum Electronic Technology Co., Ltd Unit137, the Pacific Industry Area, Xintang Town, Zengcheng District, Guangzh
: ou, China
: Shenzhen Alpha Product Testing Co., Ltd. Building B, East Area of Nanchang Second, Industrial Zone, Gushu 2nd Road,
: Bao'an, Shenzhen, China

Report No.

: T1860532 01

Date of Receipt

: July 14, 2016

Date of Test

: July 14-25, 2016

Date of Report

: July 26, 2016

Version Number : REV0

Page 2 of 36

Report No.: T1860532 01

Contents
1. General Information............................................................................................................... 4
1.1. Description of Device (EUT) ...............................................................................4 1.2. Accessories of device (EUT) ...............................................................................5 1.3. Test Lab information ............................................................................................5
2. Summary of test ...................................................................................................................... 6
2.1. Summary of test result .........................................................................................6 2.2. Assistant equipment used for test.........................................................................6 2.3. Block Diagram .....................................................................................................7 2.4. Test mode .............................................................................................................7 2.5. Test Conditions.....................................................................................................8 2.6. Measurement Uncertainty (95% confidence levels, k=2) ....................................8 2.7. Test Equipment.....................................................................................................9
3. Radiation Emission ............................................................................................................... 10
3.1. Radiation Emission Limits(15.209&231) ..........................................................10 3.2. Test Setup ...........................................................................................................10 3.3. Test Procedure ....................................................................................................12 3.4. Test Equipment Setting For emission test. .........................................................13 3.5. Test Condition ....................................................................................................13 3.6. Test Result ..........................................................................................................13
4. POWER LINE CONDUCTED EMISSION ....................................................................... 17
4.1. Conducted Emission Limits (15.209) ................................................................17 4.2. Test Setup ...........................................................................................................17 4.3. Test Procedure ....................................................................................................18 4.4. Test Results ........................................................................................................18
5. Occupied bandwidth............................................................................................................. 21
5.1. Test limit.............................................................................................................21 5.2. Method of measurement.....................................................................................21 5.3. Test Setup ...........................................................................................................21 5.4. Test Results ........................................................................................................21
6. Transmission time................................................................................................................. 23
6.1. Test limit.............................................................................................................23 6.2. Method of measurement.....................................................................................23 6.3. Test Setup ...........................................................................................................23 6.4. Test Results ........................................................................................................24
7. Antenna Requirement .......................................................................................................... 26
7.1. Standard Requirement ........................................................................................26 7.2. Antenna Connected Construction ......................................................................26 7.3. Result..................................................................................................................26
8. Test setup photo .................................................................................................................... 27 9. Photos of EUT ....................................................................................................................... 29

Page 3 of 36

Report No.: T1860532 01

Applicant Manufacturer Product

DECLARATION
: Guangzhou Netum Electronic Technology Co., Ltd : Guangzhou Netum Electronic Technology Co., Ltd : Wireless Barcode Scanner

(A) Model No.

NT-1203, 1205, 1206, 1209, 2018, 6800, 6900, 9600, : 2028, H2, H3, R1, R2, Z1, Z2, Z3, G2, M2, RD1908,
200, 300, 6870W, 6860W,1900

(B) Trade Name : N/A
(C) Power supply : DC 3.7V From Battery, DC 5V From Base for charge
Measurement Standard Used: FCC Rules and Regulations Part 15 Subpart C Section 15.231: 2015, ANSI C63.4:2014 ANSI C63.10:2013
The device described above is tested by Shenzhen Alpha Product Testing Co., Ltd. to determine the maximum emission levels emanating from the device. The maximum emission levels are compared to the FCC Part 15 Subpart C limits both conducted and radiated emissions. The test results are contained in this test report and Shenzhen Alpha Product Testing Co., Ltd. is assumed of full responsibility for the accuracy and completeness of these tests.
After the test, our opinion is that EUT compliance with the requirement of the above standards.
This report applies to above tested sample only. This report shall not be reproduced in parts without written approval of Shenzhen Alpha Product Testing Co., Ltd.

Tested by (name + signature).............:

Reak Yang Test Engineer

.....................................

Approved by (name + signature).......:

Simple Guan ....................................
Project Manager

Date of issue...... .......................:

July 26, 2016

1. General Information

1.1. Description of Device (EUT)

EUT

: Wireless Barcode Scanner

Model No. DIFF.

: NT-1203, 1205, 1206, 1209, 2018, 6800, 6900, 9600, 2028, H2, H3, R1,
R2, Z1, Z2, Z3, G2, M2, RD1908, 200, 300, 6870W, 6860W,1900
: Only Differ in model name

Trade mark

: N/A

Power supply : DC 3.7V From Battery, DC 5V From Base for charge

Operation frequency Channel

: 443333..77991MMHHzz : 1

Modulation

: GFSK

Antenna Type : Internal antenna, max gain 0dBi.

Applicant

: Guangzhou Netum Electronic Technology Co., Ltd

Address

: Unit137, the Pacific Industry Area, Xintang Town, Zengcheng District, G uangzhou, China

Manufacturer

Guangzhou Netum Electronic Technology Co., Ltd

Address

Unit137, the Pacific Industry Area, Xintang Town, Zengcheng District, G uangzhou, China

1.2. Accessories of device (EUT)

Accessories Model Input Output Accessories2 Model

: N/A : N/A : N/A : N/A : N/A : N/A

1.3. Test Lab information
Shenzhen Alpha Product Testing Co., Ltd. Building B, East Area of Nanchang Second, Industrial Zone, Gushu 2nd Road, Bao'an, Shenzhen, China
March 25, 2015 File on Federal Communication Commission Registration Number: 203110
July 18, 2014 Certificated by IC Registration Number: 12135A

2. Summary of test

2.1. Summary of test result
Description of Test Item Spurious Emission

Standard Section 15.231&15.209

Results
PASS

Conduction Emission

Section 15.207

PASS

Occupied bandwidth

Section 15.231

PASS

Transmission time

Section 15.231

PASS

Band Edge

Section 15.231

N/A

Antenna Requirement

Section 15.203

PASS

Duty cycle

Section 15.231&15.35

PASS

Note Test according to ANSI C63.4-2014 and ANSI C63.10-2013

2.2. Assistant equipment used for test

Description1

: Notebook

Manufacturer

: ACER

Model No.

: ZQR

Remark: FCC DOC approved

Description2

: Scanner Base

Manufacturer

: FARSUN

Model No.

: FS-WX2800

Remark: FCC DOC approved

2.3. Block Diagram
1. For radiated emissions test: EUT was placed on a turn table, which is 0.8 meter high above ground. EUT was set into test mode before test. New battery is used during all test

Notebook

BASE

EUT

2.4. Test mode
EUT work in Continuous TX mode, and select test channel, wireless mode

Tested mode, channel, and data rate information

Mode

Channel

Frequency

(MHz)

GFSK

CH1

433.79

Channel ...

Frequency (MHz)
...

2.5. Test Conditions

Temperature range Humidity range Pressure range

21-25 40-75% 86-106kPa

2.6. Measurement Uncertainty (95% confidence levels, k=2)

Item Uncertainty for Power point Conducted Emissions Test Uncertainty for Radiation Emission test in 3m chamber
(30MHz to 1GHz)
Uncertainty for Radiation Emission test in 3m chamber (1GHz to 25GHz)
Uncertainty for conducted RF Power

MU 2.71dB 3.90 dB 3.92dB 4.26 dB 4.28 dB 0.16dB

Remark
Polarize: V Polarize: H Polarize: H Polarize: V

2.7. Test Equipment

Equipment
3m Semi-Anechoic Spectrum analyzer

Manufacture CHENYU
Agilent

Model No. N/A

Serial No. N/A

CLaalsDt ucael. Cal Interval
Due to 2018.01.18 2Year

E4407B MY46185649 2017.01.16 1Year

Receiver

R&S

ESPI

101873 2017.01.16 1Year

Receiver

R&S

ESCI

101165 2017.01.16 1Year

Bilog Antenna SCHWARZBECK VULB 9168 VULB9168-438 2018.01.18

Horn Antenna L.I.S.N.#1

BBHA 9120 SCHWARZBECK BBHA 9120 D
D(1201) Schwarzbeck NSLK8126 8126466

2017.01.20 2017.01.16

2Year 2Year 1 Year

L.I.S.N.#2 Cable

ROHDE&SCHWA RZ
Resenberger

ENV216 N/A

101043 2017.01.16 1 Year

No.1

2017.01.16 1Year

Cable

SCHWARZBECK N/A

No.2

2017.01.16 1Year

Cable

SCHWARZBECK N/A

No.3

2017.01.16 1Year

Pre-amplifier

HP

HP8347A 2834A00455 2017.01.18 1Year

Pre-amplifier
vector Signal Generator
vector Signal Generator
X-series USB Peak and Average
Power Sensor X-series USB Peak and Average Power Sensor
Signal Analyzer

Agilent Agilent Agilent Agilent
Agilent Agilent

8449B

3008A02664 2017.01.18 1Year

N5182A MY49060042 2016.11.16 1 Year

E4438C US44271917 2016.11.16 1 Year

U2021XA MY54080020 2016.11.16 1 Year

U2021XA MY54110001 2016.11.16 1 Year N9020A MY48030494 2016.11.16 1 Year

Remark: 1 For the relevant Conducted Measurement, the temporary antenna connector is used during the measurement. Antenna Connector Impedance: 50 , Cable Loss: 1.0 dB

3. Radiation Emission
3.1. Radiation Emission Limits(15.209&231e)

Carrier

433.79MHz

dB7u2V.7/m(A@V3m)

3

frequency

72.8(AV)

3 m

Carrier

d9B2uV.7/m(P@K3)m

3

433.79MHz

frequency

92.8(PK)

3 m

NOTE: a) The tighter limit applies at the band edges. b) Emission Level(dB uV/m)=20log Emission Level(Uv/m)

3.2. Test Setup See the next page.

Below 30MHz Test Setup Above 30MHz Test Setup

1.5m
Above 1GHz Test Setup
3.3. Test Procedure
a) The measureing distance of 3m shall be used for measurements at frequency up to 1GHz and above 1GHz, The EUT was placed on a rotating 0.8 m high above ground,The table was rotated 360 degrees to determine the position of the highest radiation
b) The Test antenna shall vary between 1m and 4m,Both Horizontal and Vertical antenna are set ot make measurement.
c) The initial step in collecting conducted emission data is a spectrum analyzer Peak detector mode pre-scanning the measurement frequency range. Significent Peaks are then marked. and then Qusia Peak Detector mode remeasured
d) If Peak value comply with QP limit Below 1GHz.The EUT deemed to comply with QP limit. But the Peak value and average value both need to comply with applicable limit above 1GHz.
e) For the actual test configuration, please see the test setup photo.

3.4. Test Equipment Setting For emission test.

9KHz~150KHz 150KHz~30MHz 30MHz~1GHz Above 1GHz

RBW 200Hz RBW 9KHz RBW 120KHz RBW 1MHz

VBW1KHz VBW 30KHz VBW 300KHz VBW 3MHz

3.5. Test Condition Continual Transmitting in maximum power(The new battery be used during Test)

3.6. Test Result

We have scanned the 10th harmonic from 9KHz to the EUT. Detailed information please see the following page.
From 9KHz to 30MHz: Conclusion: PASS
Note: The amplitude of spurious emissions which are attenuated by more than 20dB below the permissible value has no need to be reported.
Notes: 1 --Means other frequency and mode comply with standard requirements and at least have 20dB margin. Correct Factor=Cable Loss+Antenna Factor-Amplifier Gain Measurement Result=Reading + Correct Factor Margin=Measurement Result-Limit
2 ­Spectrum setting: a. Peak setting 30MHz-1GHz, RBW=100KHz, VBW=300KHz.
3- PK measure result values is less than the AVG limit values, so AV measure result values test not applicable.

Radiated Emissions Result of Inside band above 1GHz

EUT Temperature

Wireless Barcode
Scanner 25oC

Pressure

960hPa

Test Mode TX CH1

Model Name

NT-1203

Relative Humidity 56%

Test voltage

DC 3.7V From Battery

Test by

Reak

Freq. Ant. Pol Peak (MHz) H/V Reading

(dBuV)

1291.5 V 1301.37 V

53.48
52.74

Above 1GHz

AV Ant. / CL Reading CF (dBuV) (dB)
--- -10.83 --- -10.83

Actual Fs
Peak (dBuV/m)
42.65 41.41

Peak Limit (dBuV/m)
74.00 74.00

Margin (dB)

Remark

-31.35

Peak

-32.59

Peak

1291.5 H 1301.37 H

51.61 50.90

--- -10.83 --- -10.83

40.78 40.07

74.00

-33.22

Peak

74.00

-33.93

Peak

4. POWER LINE CONDUCTED EMISSION
4.1. Conducted Emission Limits (15.209)

Frequency
MHz 0.15 -0.50 0.50 -5.00 5.00 -30.00

Limits dB(V)

Quasi-peak Level

Average Level

66 -56* 56 60

56 - 46* 46 50

Notes: 1. *Decreasing linearly with logarithm of frequency. 2. The lower limit shall apply at the transition frequencies.

3.The limit decreases in line with the logarithm of the frequency in the rang of 0.15 to 0.50 MHz.

4.2. Test Setup

4.3. Test Procedure
The EUT is put on the plane 0.8m high above the ground by insulating support and is connected to the power mains through a line impedance stabilization network (L.I.S.N.). This provides a 50ohm coupling impedance for the EUT system. Please refer the block diagram of the test setup and photographs. Both sides of AC lines are checked to find out the maximum conducted emission. In order to find the maximum emission levels, the relative positions of equipment and all of the interface cables shall be changed according to ANSI C63.4-2014 on Conducted Emission Measurement. The bandwidth of test receiver (R & S ESCS30) is set at 9 kHz.
4.4. Test Results
Conclusion: PASS Detailed information please see the following page.

5. Occupied bandwidth
5.1. Test limit
Please refer section15.231 According to§15.231(C), The bandwidth of the emission shall be no wider than 0.25% of the center frequency for devices operating above 70MHz and below 900MHz.
5.2. Method of measurement
a)The bandwidth is measured at an amplitude level reduced 20dB from the reference level. The reference level is the level of the highest amplitude signal observed from the transmitter at the fundamental frequency. Once the reference level is established, the equipment is conditioned with typical modulating signal to produce the worst-case (i.e. the widest) bandwidth.
b)The test receiver RBW set 30KHz,VBW set 30KHz,Sweep time set auto.

5.3. Test Setup

EUT

Spectrum Analyzer

5.4. Test Results

EUT: Wireless Barcode Scanner M/N: NT-1203 Test Mode: Keeping TX mode Test date: 2016-07-22 Test site: RF site

Tested by: Reak

Mode

Freq 20dB Bandwidth (KHz)
(MHz)

Limit (kHz)

GFSK

433.79

14.34

1084.5

Conclusion PASS

6. Transmission time
6.1. Test limit
Please refer section15.231(e) According to §15.231(e), In addition, devices operated under the provisions of this paragraph shall be provided with a means for automatically limiting operation so that the duration of each transmission shall not be greater than one second and the silent period between transmissions shall be at least 30 times the duration of the transmission but in no case less than 10 seconds.

6.2. Method of measurement
6.2.1. Place the EUT on the table and set it in transmitting mode. 6.2.2. Remove the antenna from the EUT and then connect a low loss RF cable from the
antenna port to the spectrum analyzer. 6.2.3. Set spectrum analyzer Span = 0MHz, Sweep = 200ms.
6.2.4. Set the spectrum analyzer as RBW, VBW=1MHz, 6.2.5. Max hold, view and count how many channel in the band.
6.3. Test Setup

EUT

Spectrum Analyzer

6.4. Test Results

EUT: Wireless Barcode Scanner M/N: NT-1203 Test Mode: Keeping TX mode Test date: 2016-07-22 Test site: RF site

Mode

Freq (MHz)

Test Result(S)

GFSK

433.79

0.3

Tested by: Reak Limit (S) <1S

Conclusion PASS

EUT: Wireless Barcode Scanner M/N: NT-1203 Test Mode: Keeping TX mode Test date: 2016-07-22 Test site: RF site

Tested by: Reak

Mode

Freq (MHz)

Silent Period(S)

Limit (S)

Conclusion

GFSK

433.79

10.92

>10S

PASS

Note: According OP, EUT interval 11S transmitter a time, compliance with 15.231e

section.

7. Antenna Requirement
7.1. Standard Requirement
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this Section. The manufacturer may design the unit so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector is prohibited.
7.2. Antenna Connected Construction
The directional gains of antenna used for transmitting is 0dBi, and the antenna connector is de- signed with permanent attachment and no consideration of replacement. Please see EUT photo for details.
7.3. Result
The EUT antenna is Integrated antenna. It comply with the standard requirement.

8. Test setup photo
Photos of Radiated emission

Photos of Power Line Conducted Emission

9. Photos of EUT

---------END OF THE REPORT-------


Acrobat Distiller 9.0.0 (Windows)