Shelly Wave Pro 3
3-circuit DIN-mountable Z-Wave® smart switch with potential-free contacts
User and Safety Guide
This document contains important technical and safety information about the Device, its safe use and installation.
⚠ CAUTION!
Before beginning the installation, please read carefully and entirely this guide. Failure to follow the installation procedures could lead to malfunction, danger to your health and life, violation of law or refusal of legal and/or commercial guarantee. Shelly Europe Ltd. is not responsible for any loss or damage in case of incorrect installation or improper operation of this device.
Terminology
- Gateway: A Z-Wave® gateway, also referred to as a Z-Wave® controller, Z-Wave® main controller, Z-Wave® primary controller, or Z-Wave® hub, etc., is a device that serves as a central hub for a Z-Wave® smart home network.
- S button: The Z-Wave® Service button, used for functions such as inclusion, exclusion, and resetting the device.
- Device: Refers to the Shelly Qubino device that is the subject of this guide.
About Shelly Qubino
Shelly Qubino is a line of microprocessor-managed devices that allow remote control of electric circuits via smartphone, tablet, PC, or home automation system. They operate on the Z-Wave® wireless communication protocol, requiring a gateway for configuration. When the gateway is internet-connected, devices can be controlled remotely. Shelly Qubino devices are compatible with other Z-Wave® certified devices, and mains-operated nodes act as repeaters to increase network reliability.
Wave Pro Series
The Wave Pro series is suitable for homes, offices, retail stores, and manufacturing facilities. Pro devices are DIN-mountable inside the breaker box, ideal for new construction. All Wave Pro devices can be controlled and monitored through the Z-Wave® network.
About the Device
The Device is a DIN rail mountable 3-channel smart switch with potential-free contacts. It controls the on/off function for three independent electrical devices with a load up to 16 A per channel (48 A in total). It is compatible with switches (default) and push-buttons.
Installation Instructions
The Device can be DIN-mounted inside the breaker box. Refer to the wiring scheme (Fig. 1) in this user guide.
- ⚠ CAUTION! Danger of electrocution. Installation must be performed by a qualified electrician.
- ⚠ CAUTION! Ensure no voltage is present at the Device terminals before making any connection changes.
- ⚠ CAUTION! Use the Device only with a power grid and appliances that comply with all applicable regulations.
- ⚠ CAUTION! Do not connect the Device to appliances exceeding the given max. load.
- ⚠ CAUTION! Allow at least 10 mm of space around each Pro device if expecting currents higher than 5 A per channel.
- ⚠ CAUTION! Do not shorten the antenna.
- ⚠ RECOMMENDATION: Place the antenna away from metal elements to avoid signal interference.
- ⚠ RECOMMENDATION: Connect the Device using solid single-core cables or stranded cables with ferrules. Use cables with insulation resistant to heat, not less than PVC T105°C (221°F).
- ⚠ RECOMMENDATION: For inductive appliances causing voltage spikes (e.g., motors, fans), connect an RC snubber (0.1 µF / 100 Ω / 1/2 W / 600 V AC) parallel to the appliance.
- ⚠ CAUTION! Do not allow children to play with connected buttons/switches or remote control devices.
LEGEND:
Device terminals: N (Neutral), L (Live 110-240 V AC), SW (SW1, SW2, SW3 - Switch/push-button input), I1, I2, I3 (Load circuit input), O (O1), O2, O3 (Load circuit output).
Wires: N (Neutral), L1(A), L2(B), L3(C) (Live wires).
Button: S (Service button).
Wiring Diagram Description (Fig. 1): Connect input terminals I1, I2, and I3 to corresponding circuit breakers. Connect the three load circuits to output terminals O1, O2, and O3 and the Neutral cable. The N terminal connects to the Neutral cable. The L terminal connects to the Device power supply circuit breaker. Connect three switches/push-buttons to SW1, SW2, and SW3 terminals.
For more detailed installation instructions, use cases, and comprehensive guidance, refer to the extended user guide at: https://shelly.link/WavePro3-KB-US
Specifications
Power supply | 110-240 V AC, 50/60 Hz |
Power consumption | < 0.3 W |
Max. switching voltage AC | 240 V |
Max. switching current AC | 16 A per channel, 48 A total |
Max. switching voltage DC | 30 V |
Max. switching current DC | 16 A per channel, 48 A total |
Overheating protection | Yes |
Power measurement (W) | No |
Distance | Up to 40 m indoors (131 ft.) (depends on local condition) |
Z-Wave® repeater | Yes |
CPU | Z-Wave® S800 |
Z-Wave® frequency bands | 908.42MHz, 912MHz, 920MHz |
Maximum radio frequency power transmitted | < 25 mW |
Size (H x W x D) | 96x53x59 ±0.5 mm / 3.78x2.01x2.32 ±0.02 in |
Weight | 150 g / 5.29 oz. |
Mounting | DIN rail |
Screw terminals max. torque | 0.4 Nm / 4.43 lbin |
Conductor cross section | 0.5 to 2.5 mm² / 20 to 14 AWG (green connectors) |
Conductor stripped length | 6 to 7 mm / 0.24 to 0.28 in (green connectors) |
Shell material | Plastic |
Color | Black |
Ambient temperature | -20°C to 40°C / -5°F to 105°F |
Humidity | 30% to 70% RH |
Max. altitude | 2000 m / 6562 ft. |
Operational Instructions
The operation of each output (O1, O2, O3) depends on the configuration of its corresponding input terminal (SW1, SW2, SW3). If configured as a switch (default), toggling the switch changes the output state. If configured as a push-button, pressing the button changes the output state.
Supported Load Types
- Resistive (incandescent bulbs, heating devices)
- Inductive with RC Snubber (LED light drivers, transformers, fans, refrigerators, air-conditioners)
- Capacitive (capacitor banks, electronic equipment, motor start capacitors)
Important Disclaimer
Z-Wave® wireless communication may not always be 100% reliable. This Device should not be used in situations where life and/or valuables are solely dependent on its functioning. If the Device is not recognized by your gateway or appears incorrectly, you may need to change the Device type manually and ensure your gateway supports Z-Wave Plus® multi-channel devices.
Disposal & Recycling
This symbol on the product or accompanying literature indicates that the product should not be disposed of with normal household waste. The Wave Pro 3 must be recycled to prevent potential damage to the environment or human health from uncontrolled waste disposal and to promote the reuse of materials and resources. It is your responsibility to dispose of the device separately from general household waste when it is no longer usable.
FCC Notes
This device complies with Part 15 of the FCC Rules. Operation is subject to two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received. The manufacturer is not responsible for radio or TV interference caused by unauthorized modifications. This equipment complies with FCC radiation exposure limits for an uncontrolled environment.
Manufacturer
Shelly Europe Ltd.
Address: 51 Cherni Vrah Blvd., building 3, floor 2 and 3, Lozenetz Region, Sofia 1407, Republic of Bulgaria
Tel.: +359 2 988 7435
E-mail: zwave-shelly@shelly.cloud
Support: https://support.shelly.cloud/
Ordering Code: QPSW-0A3X16US