Troubleshooting - Specifications

Troubleshooting Guide

ProblemCauseCorrection
Engine is running, but no AC output is available.1. Circuit breaker is open.
2. Fault in generator.
3. Poor connection or defective cord set.
4. Connected device is bad.
1. Reset circuit breaker.
2. Contact authorized service facility.
3. Check and repair.
4. Connect another device that is in good condition.
Engine runs good at no-load but "bogs down" when loads are connected.1. Short circuit in a connected load.
2. Engine speed is too slow.
3. Shorted generator circuit.
4. Clogged or dirty fuel filter.
1. Disconnect shorted electrical load.
2. Contact authorized service facility.
3. Contact authorized service facility.
4. Clean or replace fuel filter.
Engine will not start; starts and runs rough or shuts down when running.1. Fuel selector switch set to OFF (O) position.
2. The indicator light is OFF or flashing red.
3. Low oil level.
4. Dirty air cleaner.
5. Out of gasoline.
6. Stale gasoline.
7. Spark plug wire not connected to spark plug.
8. Bad spark plug.
9. Water in gasoline.
10. Flooded.
11. Excessively rich fuel mixture.
12. Clogged or dirty fuel filter.
13. Starting battery may have insufficient charge.
14. Out of LPG/NG.
15. LPG cylinder knob / NG supply valve is not open.
16. Out of battery power.
1. Set fuel selector switch to “GAS” or "LPG/NG" position.
2. Must have solid red indicator light to be able to start the engine.
3. Fill crankcase to proper level or place generator on level surface.
4. Clean or replace air cleaner.
5. Fill fuel tank with gasoline.
6. Drain fuel tank and carburetor; fill with fresh gasoline.
7. Connect wire to spark plug.
8. Replace spark plug.
9. Drain gas tank and carburetor; fill with fresh gasoline.
10. Wait 5 minutes and re-crank engine.
11. Contact authorized service facility.
12. Clean or replace fuel filter.
13. Check battery output and charge battery as necessary.
14. Replace LPG cylinder/check NG supply.
15. Fully open LPG cylinder knob / NG supply valve.
16. Start Engine in “GAS" position. Charge or replace battery.
Engine lacks power.1. Load is too high.
2. Dirty air filter.
3. Clogged or dirty fuel filter.
4. Clogged spark arrester.
1. Don't Overload Generator.
2. Replace air filter.
3. Clean or replace fuel filter.
4. Clean or replace spark arrester.
Engine "hunts" or falters.1. Carburetor is running too rich or too lean.
2. Clogged or dirty fuel filter.
1. Contact authorized service facility.
2. Clean or replace fuel filter.
Engine shuts down when running.1. Out of gasoline or LPG/NG.
2. Dirty air cleaner.
3. Low oil level.
1. Fill fuel tank with gasoline or replace LPG cylinder / check NG supply.
2. Clean or replace air cleaner.
3. Fill crankcase to proper level or place generator on level surface.
Engine shuts down and yellow CO fault light blinking.1. CO system fault1. Contact authorized FIRMAN service facility.

For all other issues, contact authorized dealer or FIRMAN customer service.

Specifications

ModelT08072
Starting Watts10000(GASOLINE)/9050(LPG)/6900(NG)
Running Watts*8000(GASOLINE)/7250(LPG)/5500(NG)
Rated AC Voltage120/240V
Rated Frequency60Hz
PhaseSingle
Voltage RegulatorAVR
Power Factor1
Alternator TypeBrushed
EngineFIRMAN
Engine TypeSingle Cylinder, 4-Stroke OHV Air Cooled
Displacement439cc
Low Oil ShutdownYes
Ignition SystemBreakless Ignition Type, Flywheel Magneto
Starting SystemRecoil/Electric Start
FuelUnleaded Automotive Gasoline/LPG/NG
Capacity Fuel Tank8.0 U.S. Gallons (30.3L)
Lubricating Oil Capacity37.2 oz (1.1L)
Carburetor TypeFloat
Air CleanerPolyurethane Type
P.T.O. Shaft RotationCounter Clockwise (Facing P.T.O.)
Oil TypeSee "Add Engine Oil" Section
AC Grounding SystemNeutral Bonded To Frame
Natural gas fuel pressure range7-11 inches water column (0.25-0.40 psi)(13-20mm mercury)(1.7-2.7 kpa)
Natural gas fuel consumptionNo Load: 72ft³/hr(2m³/hr)
72,000 BTU/h (21,101 W)
Half Load: 86ft³/hr(2.4m³/hr)
86,000 BTU/h (25,204 W)
Full Load: 101ft³/hr(2.9m³/hr)
101,000 BTU/h (29,593 W)
LPG fuel consumptionNo Load: 15.6ft³/hr(1.6L/hr)
39,000 BTU/h (11,429 W)
Half Load: 33ft³/hr(3.4L/hr)
82,500 BTU/h (24,176 W)
Full Load: 54.6ft³/hr(5.7L/hr)
136,500 BTU/h (40,000 W)

*Generator certified in accordance with CSA (Canadian Standards Association) standard C22.2No. 100-14, Motors and Generators and complies with PGMA (Portable Generator Manufacturers' Association) standard ANSI/PGMA G300-2018, Safety and Performance of Portable Generators.

English 35 Customer Service: 1-844-FIRMAN1

Models: T08072, 10000 or 8000 Watt Tri Fuel Portable Generator, T08072 10000 or 8000 Watt Tri Fuel Portable Generator

PDF preview unavailable. Download the PDF instead.

77c0266c-2971-4bf2-8c38-082801a5ee60 macOS Version 12.4 (Build 21F79) Quartz PDFContext CorelDRAW

Related Documents

PreviewFirman Generator Quick Start Guide: Safe Operation and Setup
Concise guide for starting and stopping your Firman portable generator, including safety instructions for carbon monoxide prevention and using extension cords.
PreviewFirman Portable Generator Quick Start / Stop Guide
Concise guide for starting and operating your Firman portable generator, including essential safety instructions for carbon monoxide prevention and safe extension cord usage.
PreviewFirman Generator Quick Start and Stop Guide
Quick Start and Stop Guide for Firman portable generators. Learn essential setup, safe operation, and carbon monoxide prevention tips. Includes included items and control identification.
PreviewFIRMAN Generator Quick Reference Guide
A quick reference guide for setting up and operating a FIRMAN generator, including unpacking, initial setup, starting procedures (recoil and electric start), and shutdown/storage instructions. This guide is intended as a supplement to the full operator's manual.
PreviewFIRMAN T07571 Tri-Fuel Portable Generator Operator's Manual
This operator's manual provides essential guidance for the safe and effective use of the FIRMAN T07571 Tri-Fuel Portable Generator. It covers critical safety information, operational procedures, maintenance schedules, troubleshooting, and warranty details for gasoline, LPG, and natural gas.
PreviewFirman Generator Quick Start / Stop Guide - T07573 Model Operation and Safety
A concise quick start and stop guide for the Firman T07573 Tri-Fuel Generator, covering setup, operation, and critical safety information regarding carbon monoxide poisoning and extension cord usage.
PreviewFirman Generator Quick Start and Stop Guide
A quick start and stop guide for the Firman generator, providing essential safety information and basic operating instructions. Includes details on preventing carbon monoxide poisoning and connecting extension cords.
PreviewFIRMAN WH02942 Dual Fuel Inverter Generator Owner's Manual
This owner's manual provides comprehensive guidance on the safe operation, maintenance, and troubleshooting of the FIRMAN WH02942 Dual Fuel Inverter Generator, including safety warnings and warranty information.