Drywall Grid Systems: Hanging & Framing Flat Ceilings

Inspiring Great Spaces®

Armstrong CEILING SOLUTIONS

Work Smarter

Eliminate the labor-intensive cutting, tying, and spacing of track and channel framing. Armstrong's Drywall Grid Systems are engineered with rout locations and cross tees to maintain precise module spacing. Main beams feature 51 rout locations and cross tees are available in 50", 26", and 14" lengths to accommodate Type F fixtures without field modifications or accessories. Pre-notched main beams simplify curved drywall installations.

Our Drywall Systems are manufactured to meet or exceed ASTM standards and code requirements, and are engineered to provide economical alternatives to stud and track construction.

The vertical load carrying capacity for main beam and cross tee members is determined in accordance with ASTM test method E3090. Suspended ceiling systems constructed of screw-attached gypsum board panels may be installed in accordance with ASTM C1858 and are exempt from code prescribed requirements of acoustical or lay-in panel ceilings. This standard practice is limited to framing that supports a single level ceiling and is surrounded by and attached to laterally braced walls or soffits.

Drywall Grid Systems: Code Compliance You Can Trust

Meets:

Consult local codes for specific requirements.

Performance

Components

Main Beams

Item Number Length Dimension Face Height Profile Load Duty Fire Rated Routs Load Test Data (Lbs/LF) Perspective
L/240 Simple Span L/360 Simple Span
HD8906 / HD8906G90 144" 1-1/2" x 1-11/16" Heavy Duty Yes 51 routs - starting 2-1/4" from each end+ 143.00 57.30 28.14 95.5 43.19 18.66 [Image of main beam]
HD8906HRC
HD8906IIC 144" 1-1/2" x 1-11/16" Heavy Duty Yes 51 routs - starting 2-1/4" from each end+ 143.00 57.30 28.14 95.5 43.19 18.66 [Image of main beam]
HD890610 120" 1-1/2" x 1-11/16" Heavy Duty Yes 51 routs - starting 2-1/4" from each end+ 143.00 57.30 28.14 95.5 43.19 18.66 [Image of main beam]

Metric

Item Number Length Dimension Face Height Profile Load Fire Rated Routs Hanger Spacing (KG/LM)
600mm 900mm 1200mm 600mm 900mm 1200mm
HD7940 3600mm 30mm x 38mm Yes 200mm O.C. 150.0 68.3 29.34 100.0 45.35 19.56
7940G 3600mm 30mm x 38mm Yes 150mm O.C. - starting 75mm from each end+ 114.0 51.92 22.40 76.39 34.61 14.93

+ Type F fixture compatible

Cross Tees

Item Number Length Dimension Face Height Profile Fire Rated Routs Load Test Data (Lbs/LF) Perspective
L/240 Simple Span L/360 Simple Span
2' 3' 4' 2' 3' 4'
XL8965 / XL8965HRC 72" 1-1/2" x 1-1/2" Yes 6 routs - starting 24" from each end+ 6.87 4.58 [Image of cross tee]
XL8947P / XL8947PG90 50" 1-1/2" x 1-1/2" Yes 8 routs - starting 10" from each end+ 19.5 12.79 [Image of cross tee]
XL8945P / XL8945PG90 / XL8945HRC 48" 1-1/2" x 1-1/2" Yes 9 routs center rout and starting 10" from each end+ 22.5 14.27 [Image of cross tee]
XL7936G90 36" 1-1/2" x 1-1/2" No 50.00 31.33 [Image of cross tee]
XL8926 / XL8926G90 24" 1-1/2" x 1-1/2" Yes 3 routs center rout and 10" from each end+ 158.0 90.25 [Image of cross tee]

Metric

Item Number Length Dimension Face Height Profile Fire Rated Routs Load Total Data (KG/LM)
L/240 L/360 L/240 L/360 L/240 L/360
XL7961 1600mm 30mm x 38mm Yes 800mm center of tee 10.25 @ 6' 6.84 @ 6' 15.15 @ 1600mm 10.18 @ 1600mm
XL7930 1200mm 30mm x 38mm Yes 450mm, 600mm, 750mm 22.4 @ 4' 14.93 @ 4' 33.33 @ 1200mm 22.22 @ 1200mm
XL7925 900mm 30mm x 38mm No none 51.92 @ 3' 34.61 @ 3' 77.26 @ 900mm 51.51 @ 900mm

NOTE: All items available in High Recycled Content (HRC) as special order.

Molding

Item Number Length Description Profile Perspective
7858 144" Reverse Angle Molding nominal 1-9/16" x 15/16" [Image of molding profile] [Image of molding perspective]
KAM10 120" Knurled Angle Molding nominal 1-1/4" x 1-1/4" [Image of molding profile] [Image of molding perspective]
KAM12 / KAM12G90 / KAM12HRC 144" Knurled Angle Molding nominal 1-1/4" x 1-1/4" [Image of molding profile] [Image of molding perspective]
KAM1510 / KAM1512 / KAM151020 / KAM151020EQ 120" / 144" Knurled Angle Molding nominal 1-1/2" x 1-1/2" (25 ga.; 20 ga.; 22 ga.) [Image of molding profile] [Image of molding perspective]
KAM21020 / KAM21025 / KAM21020EQ 120" / 144" Knurled Angle Molding nominal 2" x 2" (20 ga.; 25 ga.; 22 ga.) [Image of molding profile] [Image of molding perspective]
LAM12 / LAM12G90 / LAM12HRC 144" Locking Angle Molding nominal 1-1/4" x 1-1/4" [Image of molding profile] [Image of molding perspective]
LAM151220E 144" 1-1/2" x 1-1/2" [Image of molding profile] [Image of molding perspective]
SC151220EQ / SC151225 148" SimpleCurve™ Knurled Angle Molding (12' x 1.5" - 20 ga.; 12' x 1.5" - 25 ga.) [Image of molding profile] [Image of molding perspective]
SC21220EQ / SC21225 148" SimpleCurve™ Knurled Angle Molding (12' x 2" - 20 ga.; 12' x 2" - 25 ga.) [Image of molding profile] [Image of molding perspective]

NOTE: All items available in High Recycled Content (HRC) as special order.

[Diagram showing SimpleCurve™ Knurled Angle Molding used with 5/8" Gypsum Board]

Corrosion Prevention

Corrosion prevention is an essential factor in the economical utilization of galvanized sheet metal for ceiling suspension systems. Armstrong Ceilings provides G40 for standard construction per ASTM C645. When conditions include exposure to extreme moisture and salt water, G90 is available per ASTM A653.

Material: Commercial-quality cold rolled hot dipped galvanized steel

Item Number Length/Item Description Face Dimension Flange Height Profile Perspective
7901 120" Shadow Reveal Molding 3/8" shadow reveal 9/16" 1-1/4" [Image of molding]
7902 120" Shadow Reveal Molding 3/8" shadow reveal 15/16" 1-1/4" [Image of molding]
7903 120" Inverted T Molding 1" inverted T 1-1/2" [Image of molding]
7904 / 7904PF* 120" Flush Transition Molding 15/16" horizontal 15/16" 1-1/4" [Image of molding]
7905 / 7905PF* 120" Flush Transition Molding 9/16" horizontal 9/16" 1-1/4" [Image of molding]
7906 120" F Molding 120" vertical transition 1/2" 1-7/16" [Image of molding]
7907 120" Tegular Transition Molding 9/16" horizontal 9/16" 1-1/4" [Image of molding]
7908 120" Tegular Transition Molding 15/16" horizontal 15/16" 1-1/4" [Image of molding]
7909 15/16" 1" Step Transition Molding 15/16" horizontal 15/16" 1-7/8" [Image of molding]
7910 9/16" 1" Step Transition Molding 9/16" horizontal 9/16" 1-7/8" [Image of molding]
7911 9/16" Shadow Reveal Transition Molding 3/8" x 1/4" shadow reveal 9/16" 1-1/8" [Image of molding]
7912 15/16" Shadow Reveal Transition Molding 3/8" x 1/4" shadow reveal 15/16" 1-1/4" [Image of molding]

* 7904PF and 7905PF feature protective film on the acoustical wall angle flange for faster, easier finishing.

Axiom® Trim

Axiom Drywall Transitions

Item Number Length/Item Description Dimensions Perspective
AXTRVESTR Straight Transition for Vector® Ceiling 120 x 2-9/16 x 1-11/16" [Diagram: Axiom - Transitions with Vector® panel to drywall perimeter]
AXTRTECUR Curved Transition for Tegular 120 x 2-9/16 x 1-11/16" [Diagram: Axiom - Transitions with Tegular panel to drywall perimeter]
AXTR2STR 2" Straight Transition 120 x 2 x 1-1/2" [Diagram: Acoustical-to-Drywall]
AXTR2CUR 2" Curved Transition 120 x 2 x 1-1/2" [Diagram: Drywall-to-Drywall]
AXTR4STR 4" Straight Transition 120 x 4 x 1-1/2" [Diagram: Acoustical-to-Drywall]
AXTR4CUR 4" Curved Transition 120 x 4 x 1-1/2" [Diagram: Drywall-to-Drywall]
AXTR6STR 6" Straight Transition 120 x 6 x 1-1/2" [Diagram: Acoustical-to-Drywall]
AXTR6CUR 6" Curved Transition 120 x 6 x 1-1/2" [Diagram: Drywall-to-Drywall]
AXTR8STR 8" Straight Transition 120 x 8 x 1-1/2" [Diagram: Acoustical-to-Drywall]
AXBTSTR Drywall Bottom Trim 120 x 1-1/8 x 27/32" [Diagram: Drywall Bottom Trim]

Accessories

Item Number Description Perspective
AX4SPLICEB Splice Plate [Image of splice plate]
AXTBC T-Bar Connector Clip [Image of clip]

Axiom One-Piece Drywall Trim

*For use with 5/8" drywall only

Material: Commercial-quality extruded aluminum alloy 6063

Item Number Length/Item Description Perspective
AX1PC2STR 2.5" One-Piece Straight Drywall Trim [Diagram: HANGER WIRE, DGS, AXTBC, 2-9/16", One-Piece Drywall Trim, 5/8" Drywall]
AX1PC2CUR 2.5" One-Piece Curved Drywall Trim [Diagram: HANGER WIRE, DGS, AXTBC, 2-9/16", One-Piece Drywall Trim, 5/8" Drywall]
AX1PC4STR 4" One-Piece Straight Drywall Trim [Diagram: HANGER WIRE, DGS, AXTBC, 4", One-Piece Drywall Trim, 5/8" Drywall]
AX1PC4CUR 4" One-Piece Curved Drywall Trim [Diagram: HANGER WIRE, DGS, AXTBC, 4", One-Piece Drywall Trim, 5/8" Drywall]
AX1PC6STR 6" One-Piece Straight Drywall Trim [Diagram: HANGER WIRE, DGS, AXTBC, 6", One-Piece Drywall Trim, 5/8" Drywall]
AX1PC6CUR 6" One-Piece Curved Drywall Trim [Diagram: HANGER WIRE, DGS, AXTBC, 6", One-Piece Drywall Trim, 5/8" Drywall]

Axiom® Building Perimeter System

Axiom Pocket with Face Plate to Drywall Transition

[Diagram showing Axiom Pocket with Face Plate to Drywall Transition, including components like Optional Stud, 3-Sided Perimeter Pocket, Foam Gasket, HVAC Boot, Splice Plate, Armstrong® Drywall Grid Cross Tee, Window, 2" Closure Clip, Interlocking Spline, Slotted Face Plate, T-Bar Connection Clip, Drywall Taping Flange, Hanger Wire, 5/8" Thick Drywall, Armstrong® Drywall Grid Main Beam]

Item Number Length/Item Description Perspective
AXP355LC 3-Sided Lutron Compatible Shade Pocket with Connection to Extension/Face Plate Piece [Image of pocket]
AXPCC2 2" Shade Closure Clip [Image of clip]
AXPCC3 3" Shade Closure Clip [Image of clip]
AXPDFP4DTSLA / AXPDFP4DTSLB 4" Axiom Perimeter Face Plate with Drywall Flange - 2 Slot Pattern / 1 Slot Pattern [Image of face plate]
AXPDFP7DT / AXPDFP7DTSLA / AXPDFP7DTSLB 7" Axiom Perimeter Face Plate with Drywall Flange - Unslotted / 2 Slot Pattern / 1 Slot Pattern [Image of face plate]

Rout Locations

Imperial

HD8906 (HRC)/HD890610* [Diagram showing rout locations for HD8906/HD890610, indicating 51 routs starting 2" from end, and length of 144" or 120"]
HD8906IIC [Diagram showing rout locations for HD8906IIC, indicating 51 routs starting 2" from end, and length of 144"]
XL8965 (HRC) (Type F Compatible) [Diagram showing rout locations for XL8965, indicating 51 routs starting 2" from end, and length of 72"]
XL8947P (Type F Compatible) [Diagram showing rout locations for XL8947P, indicating routs at 26" and 50", and lengths of 50"]
XL8945HRC/XL8945P (Type F Compatible) [Diagram showing rout locations for XL8945HRC/XL8945P, indicating routs at 10", 12", 24", 48", and lengths of 48"]

Metric

XL7936G90 [Diagram showing rout locations for XL7936G90, indicating 18 routs @ 200mm O.C. starting 100mm from end, and length of 3600mm]
XL8926 [Diagram showing rout locations for XL8926, indicating 24 routs @ 150mm O.C. starting 75mm from end, and length of 3600mm]
HD7940 [Diagram showing rout locations for HD7940, indicating 16 routs @ 200mm O.C. starting 100mm from end, and length of 3600mm]
7940G [Diagram showing rout locations for 7940G, indicating 24 routs @ 150mm O.C. starting 75mm from end, and length of 3600mm]
XL7961 [Diagram showing rout locations for XL7961, indicating routs at 800mm and 1600mm, and length of 1600mm]
XL7930 [Diagram showing rout locations for XL7930, indicating routs at 450mm, 600mm, 750mm, and 1200mm]
XL7925 [Diagram showing rout locations for XL7925, indicating routs at 600mm and 900mm]
XL7920 [Diagram showing rout locations for XL7920, indicating routs at 600mm]

Accessories

Drywall Grid Accessories

A variety of drywall grid accessories are available to provide problem-solving solutions that save time, labor, and money. For a complete list of accessories, request submittal BPCS-3082.

Item Number Quantity Description Perspective Application
DWACS 100 Drywall Attachment Clip facilitates transition from drywall to acoustical ceiling; locks under bulb of grid section to prevent upward movement and provide secure attachment surface on one side of exposed grid. [Image of DWACS] [Image of DWACS application]
DW30C, DW45C, DW60C, DW90C 250 30-, 45-, 60-, and 90-degree Drywall Angle Clips are used to create positive and secure angles for drywall and ceiling installations on either main beams or cross tees. [Images of DW30C, DW45C, DW60C, DW90C] [Image of angle clip application]
TT10 30 Partition Top Trim is used to finish the top of a drywall partition for a continuous drywall/acoustical ceiling interface. [Image of TT10] [Image of TT10 application]
DW58LT 125 DW58LT - Transition Clip for 5/8" Drywall with Locking Tabs; facilitates transition from drywall to acoustical ceiling; one-sided hold down clip; eliminates need for drywall bead. Locking tabs provide secure location for Drywall Grid System tees. [Image of DW58LT] [Image of DW58LT application]
DW50LT 125 DW50LT - Transition Clip for 1/2" Drywall with Locking Tabs; facilitates transition from drywall to acoustical ceiling; one-sided hold down clip; eliminates the need for a drywall bead. Locking tabs provide secure location for Drywall Grid System tees. [Image of DW50LT] [Image of DW50LT application]
IIC 36 Impact Isolation Clip for use with HD8906IIC drywall grid main beam. Provides up to 8 points of IIC improvement to ensure your project meets IBC requirements. [Image of IIC clip] [Image of IIC clip application]
MBSC2 200 Main Beam Spacer Clip (2" in length) is used to space two parallel main beams 2" O.C. for air supply or return. [Image of MBSC2] [Image of MBSC2 application]
GSC9, GSC12, GSC16 100 Adjustable Grid Spacer Clip is used to space two parallel main beams for light fixtures, air diffusers, etc.; allows for 1/4" adjustments with three different clips. [Images of GSC clips] [Image of GSC clip application]

Drywall Grid Accessories (continued)

Item Number Quantity Description Perspective Application
XTAC 100 Cross Tee Adapter Clip is used to attach field-cut cross tees to main beams. [Image of XTAC] [Image of XTAC application]
DDC 250 Double Drywall Clip is used to hang suspension system below existing 1-1/2" grid face, transferring weight directly to hanger wire; may be used to preserve the fire rating of an existing ceiling and to support heavy accessories; allows for double layer of 5/8" gypsum board. [Image of DDC] [Image of DDC application]
DLCC 250 Direct Load Ceiling Clip is used to hang suspension system below existing 15/16" grid face, transferring weight directly to hanger wire; may be used to preserve the fire rating of an existing ceiling and to support heavy accessories. [Image of DLCC] [Image of DLCC application]
DWC 250 Drywall Clip allows for a second ceiling to be installed below a drywall ceiling; attach through installed drywall to supporting structure. [Image of DWC] [Image of DWC application]
MBAC 70 Main Beam Adapter Clip attaches to web of suspension system section; provides larger surface for screw attachments; used as a hold down clip for thin material (metal or plastic lay-in panels); fastens drywall track to underside of exposed suspension system with lay-in panels, leaving suspension system face free of screw holes. [Image of MBAC] [Image of MBAC application]

System Framing

Hanging & Framing

The grid system is comprised of main beams and cross tees that are suspended by hanger wires to the structural deck. Sections of main beams lock together end-to-end while cross tees span between the main beams. The ends of the main beams and cross tees rest on the wall channel or angle molding that run around the perimeter of the space.

[Diagram illustrating hanging and framing with main beams, cross tees, hanger wires, wall channel/angle molding, and gypsum wall board. Includes labels for KAM - Knurled Angle Molding, and a note about 107 lbs. Pull Out and 372 lbs. Shear with 25 gauge Pan Head Streaker.]

Squaring Up the System

Once you've hung your first two main beams and border cross tees, install two full cross tees between the main beams in line with the first two border cross tees. To square up the system, simply measure across the diagonals of the opening. The measurements will be the same if the grid is square. If the grid is not square, shorten one of the main beams until the diagonals are equal.

[Diagram illustrating squaring up the system by measuring diagonals A and B.]

Type F Fixtures

Hanging & Framing

Type F fixtures, access panels, and air diffusers require a full 12", 24", or 48" opening dimension. The Armstrong Drywall Grid System main beams and cross tees have additional routs in the web to accommodate this larger opening for type F fixtures. Using our 14", 26", 50", and 72" cross tees, type F fixtures fit perfectly without field cutting or special accessories.

When installing type F fixtures parallel to the main beams, use a 72" and 48" cross tee for easy placement of fixtures without field modifications.

When installing fixtures perpendicular to the main beams, use 72" cross tees for virtually limitless fixture placement.

[Diagram showing main beams at 48" O.C. with placement of XL8947P, HD8906, XL8925, XL8947P, XL8965, XL8925, XL8947P, HD8906.]

[Diagram showing main beams at 72" O.C. with placement of XL8925, XL8965, XL8947P, HD8906, XL8925, XL8965, XL8947P, HD8906.]

Item No. Description Fixture Length
DGSLLTK24 2' Linear Light Trim Kit 24" x 4" [Diagram: LCBDGS4 Connector Bracket install 2' from each end and 4' O.C., Hanger Wire, DGS Main Beam, DGS Cross Tee, Taping Flange, DGSLL Aluminum Extrusion]
DGSLLTK30 2'-6" Linear Light Trim Kit 30" x 4"
DGSLLTK48 4' Linear Light Trim Kit 48" x 4"
DGSLLTK60 5' Linear Light Trim Kit 60" x 4"
DGSLLTK72 6' Linear Light Trim Kit 72" x 4"
DGSLLTK90 7'6" Linear Light Trim Kit 90" x 4"
DGSLLTK96 8' Linear Light Trim Kit 96" x 4"
DGSLLTK120 10' Linear Light Trim Kit 120" x 4"
DGSLLTKCON 10' Continuous Linear Light Trim Kit 10'

Linear Light Trim Kits designed to work with 5/8" drywall

Suspended Drywall Grid Systems

Suspended Drywall Grid System Details

[Diagram showing a layout of a suspended drywall grid system with numbered components.]

1. Butt Joint

5. Type F Fixture

9. Access Door

[Diagram showing a detail of a Butt Joint with Hanger Wire and Gypsum Board.]

[Diagram showing a detail of a Type F Fixture.]

[Diagram showing a detail of an Access Door.]

[Diagram showing details of various components: 2. Expansion Joint*, 3. Wood Trim, 4. Control Joint, 6. Air Bar, 7. High Hat Fixture, 8. Vertical Brace, 10. Securing a Single Cross Tee, 11. Channel and Angle Molding, 12. Angle Clip. Includes labels for MBSC2 Main Beam Spacer Clip, DW90C, DW60C, DW45C, DW30C, XTAC, DDC, Main Beam, Cross Tee, Drywall Screws, Expansion Joint*, Edge Bead, Screw, Wood Trim, Hanger Wire, Angle Molding, Steel Stud, Main Beam, Hanger Wire, Channel Molding, Steel Stud.]

[Diagram showing details of various components: 13. Triple Layer with Security Lath, 14. Double Layer with Security Lath, 15. Double Hung Ceiling, 16. Transition, 17. Axiom® Perimeter Trim, 18. Alternate Finishes, 19. Drywall Vertical, 20. Surface Mount Fixture, 21. Triple Layer with Sound Isolators, 22. HD8906 with IIC Clip. Includes labels for Hanger Wire, Exposed Tee Grid System, Angle Molding, Cross Tee, Acoustical Panel, Gypsum Board, Steel Stud, Drywall Grid System, Drywall Screw, Axiom® - Classic, 5/8" Gypsum Wall Board, Axiom® Drywall Bottom Trim, AXTBC, Axiom - Profiled (Convex), Drywall Screw, DDC, Hanger Wire, Main Beam, Sound Isolator by Others, Plywood or Gypsum Board, Gypsum Board, Surface Mount Light Fixture (Screwed to Main Beam), Hanger Wire, IIC Clip.]

Wire Loading

Hanging & Framing

9 Gauge Wire Breaking Strength and Technical Data

12 Gauge Wire Breaking Strength and Technical Data

[Diagram illustrating wire loading with 9 gauge and 12 gauge wire specifications.]

Counter Splayed Wires

Objects in the plenum may obstruct placement of vertical hanger wires and require splayed wires to support the load. When this occurs, a second counter splayed wire must be added. Install counter splayed wires at an angle equal and opposite to the first wire, but not greater than 45° from vertical. The load capacity of the main beam remains unchanged (refer to ASTM C636).

[Diagram illustrating counter splayed wires at 45°, 30°, and 15° angles. Includes a note: "If counter splayed wires are at unequal angles, refer to a local engineer or code official for approval."]

Yoke Wire Hung Ceilings

Hanging & Framing

Another method to install hanger wires around an object in the plenum is to utilize a single or double yoke wire technique. Rule: To form the 45-degree angle, the vertical location of the tension ring is always half the distance of the span at the structure.

Single Yoke

[Diagram illustrating single yoke wire technique with 8' span, 4' vertical drop, and 45° angle. Includes 5/8" Type USS Flat Washer or Equivalent.]

Double Yoke

[Diagram illustrating double yoke wire technique with 12' span, 6' vertical drop, and 45° angle. Includes 5/8" Type USS Flat Washer or Equivalent. Includes notes: "Maintain wire spacing at a maximum 4' O.C."]

Trapeze Supported Loads

Hanging & Framing

Installing a trapeze is a technique to support multiple hanger wires under obstructions, such as trunk lines, cable trays, or other objects in the plenum. In some cases, the trapeze may affect the ceiling height and must be kept small. In other cases, steel studs may be used to span the distance required.

[Diagram illustrating trapeze supported loads with HVAC DUCT, Duct Strap, Cable Trays, Elec. Conduit/Water Lines, Telephone Lines, Trapeze Support Independent of Equipment, Main Beam, Acoustical or Drywall Ceilings, and 4' O.C. spacing.]

Double Hung Ceilings

Hanging & Framing

A suspended ceiling not only carries the load of the applied finish, but can also act as a load carrying structure or membrane that supports another ceiling at a lower level. The DDC clip is used at hanger wire locations to allow for connecting the second and even third ceiling. This method of hanging and framing is used in multi-layer ceilings with long vertical drops – eliminating the use of long stud drops.

[Diagram illustrating double hung ceilings with DDC clips, Main Beam, Hanger Wires, Drywall Grid System, Wall Angle, Partition Wall, Sound Isolator, Double Layer Gypsum Wall Board, Steel Stud, DW45C.]

Gusset Hung Ceiling

[Diagram illustrating gusset hung ceiling with 2" x 6" Wood Block, Wire Clip or Eye Screw into Wood Block, Plumbing TW Wire Cable, Loading at Top of Wall in Wood Block, Electricity, Security, etc., #9 Wire 500 lbs., DWC Clip.]

Triple Hung Ceilings

Hanging & Framing

[Diagram illustrating triple hung ceilings with Drywall Grid System, Insulation, DDC Clip, Pipe Chase, Duct, Drywall Grid System, Drywall Grid System, DW45C, Channel Molding, Drywall Main Beam, Drywall Main Beam, DDC, Channel Molding, DW90C, Roof Deck, Bar Joist, Gypsum Board, Steel Stud. Labeled as 1st, 2nd, 3rd levels.]

Exterior Wind Load Data

Exterior Wind Load Ceiling Design for North America

[Table detailing Exterior Wind Load Ceiling Design for North America, including Plenum Height, Velocity Pressure, Design Pressure, Post Size, Post Gauge, Sheathing Membrane Substrate, Compression Post, Main Beam, Cross Tee, Hanger Wire Spacing, Tee Length, and Compression Post Load.]

NOTE: For building heights over 20 feet, refer to ASCE 7-10 Chapter 6 Wind Loads.

UL® Fire Resistive

Hanging & Framing

[Table detailing UL® Fire Resistive Floor/Ceiling Drywall Assemblies and Wood Deck/Ceiling Drywall Assemblies, including Deck Construction Type, UL® Design Number, Concrete Thickness, # Drywall Layers, Minimum Drywall Thickness, Maximum Fixture Penetration, Maximum Duct Penetration, and Drywall Grid System.]

[Table detailing UL® Fire Resistive Roof/Ceiling Drywall Assemblies, including Deck Construction Type, UL Design Number, Concrete Thickness, # Drywall Layers, Minimum Drywall Thickness, Maximum Fixture Penetration, Maximum Duct Penetration, and Drywall Grid System.]

Armstrong® Drywall "Design To Fit" Items XL7936G90 and XL8965 cannot be used as part of a UL Fire Resistive Design.

DFR 8000 - UL Designation, Fire Guard™ Drywall Grid System.

For fire-rated assemblies, use Type C gypsum board as noted in the UL fire-rated assembly designs.

Fire Rated Expansion Joint

[Diagram showing a fire expansion notch and a collapsed fire expansion notch.]

Load Data

Main Beam - Technical Load Test Data

[Table showing Main Beam Technical Load Test Data for Imperial and Metric units, including Simple Span loads.]

Cross Tees - Technical Load Test Data

[Table showing Cross Tees Technical Load Test Data for Imperial and Metric units, including Simple Span loads.]

NOTE: Allowable loads tested per ASTM C635 for deflection limited to L/360 and complies with ASTM C645 for deflection limited to L/240. See standards for additional information.

Membrane Load Values

[Table showing Membrane Load Values for Imperial and Metric units, including Maximum Load in lbs./ft.2 at Hanger Wire/Cross Tee Spacing and Maximum Load in kg/lm² at Hanger Wire/Cross Tee Spacing.]

Basic Products

Basic Products Used on Suspension Systems

[Table listing basic products used on suspension systems, including Material, Weight Lbs/SF, Maximum Main Beam Spacing, Maximum Cross Tee Spacing, Maximum Wire Spacing, and Load on Wire.]

NOTES: All framing on the exterior should be 16" O.C. or less.

Some manufacturers make 1/2" gypsum board with special core to span 24" framing on interior ceiling installations (available on request).

All steel product on exterior made from G90 galvanized finish.

Data based on manufacturer's published data.

Use lower RPM (1,000-2,500) screw gun to install cement board screws with intermittent pressure.

Control Joints

Please refer to ASTM C840, Section 20.3.3 to 20.4 for Control Joint Requirements.

[Diagram illustrating a control joint.]

Expansion Joints

Ceiling expansion joints are installed to separate the metal suspension system when expansion joints occur in buildings or when metal changes direction. Expansion joints are required to separate a system in T-, H-, I-, and U-, or circle-shaped buildings to eliminate cracking from expansion.

[Diagram illustrating an expansion joint.]

Sound Control

Hanging & Framing

The IBC uses two sound classes to measure sound isolation performance in building construction: Sound Transmission Class (STC) – sound transmitted through the air such as voices and music. Impact Insulation Class (IIC) – sound transmitted through the building structure such as foot traffic and objects dropped on the floor. A rating of 50 or above for both STC and IIC sound tests will satisfy the IBC's minimum requirements.

Understanding Sound Control Ratings

STC/IIC Ratings Description Changes in STC/IIC Ratings Description
55 Excellent +/-1 Almost perceptible
50 Loud speech barely audible +/-3 Just perceptible
45 Some loud speech audible - not understood +/-5 Clearly Perceptible
30 Loud speech audible - well understood +/-10 Twice (or half) as loud
25 Regular speech audible and understood through walls

Satisfy IBC requirements with a rating of 50 or above for STC and IIC sound tests - without two layers of drywall using Armstrong® Drywall Grid.

Traditional Assembly - Field Tested Data

Traditional Assembly Building Structure STC IIC
1-1/2" Black Iron / 7/8" Channel, 3-1/2" Batt Insulation, 5/8" Gypsum Bare Concrete Base 55 48
3" Concrete Slab, Fluted Steel Decking, 8" Bar Joist, 24" O.C. 44

Armstrong® Standard Drywall Grid Assembly - Field Tested Data

Item Number Armstrong Assembly Building Structure STC IIC
HD8906 / XL8945 12' Main Beam / 4' Cross Tee, 3-1/2" Batt Insulation, 5/8" Gypsum 6" Thick Concrete: 3500psi, Bare Concrete Base 55 47
3" Concrete Slab, Fluted Steel Decking, 8" Bar Joist, 24" O.C. 47

Armstrong® IIC Drywall Grid Assembly - Field Tested Data

Item Number Armstrong Assembly Building Structure STC IIC
HD8906IIC / XL8945 / IIC Clip 12' Main Beam / 4' Cross Tee, IIC Clip, 3-1/2" Batt Insulation, 5/8" Gypsum 6" Thick Slab Concrete Base with Vinyl Sheet Flooring 57 66

[Diagram showing Armstrong® IIC Drywall Grid Assembly with HD8906IIC 12' Main Beam, XL8945 4' DGS Tee (Wires 4' O.C.), 3-1/2" Batt Insulation, Ceiling - One Layer 5/8" Gypsum, and IIC Clip.]

Estimating

Estimating Material

[Table showing Area of ceiling completed by one carton (SF) for various grid components and spacing.]

Example calculation based on 5,100 SF ceiling:

Main beam at 48" O.C.: 5,100 SF x .25 = 1,275 LF. 1,275 LF ÷ 144 LF/Ctn = 9 cartons needed

Cross tee at 16" O.C.: 5,100 SF x .76 = 3,876 LF. 3,876 LF ÷ 144 LF/Ctn = 27 cartons needed

[Table showing Estimating Lineal Feet of Grid Based on Square Footage of Ceiling for various O.C. Spacing of Component.]

technical-guide-hanging-framing-flat-ceilings

Related Documents

Preview Armstrong Drywall Grid Systems: Technical Guide for Hanging & Framing Flat Ceilings
Comprehensive technical guide from Armstrong Ceiling Solutions detailing Drywall Grid Systems for hanging and framing flat ceilings. Covers components, code compliance, performance, installation, load data, fire resistance, and seismic considerations.
Preview ACOUSTIBuilt® Seamless Acoustical Ceiling and Wall System Installation Guide
Comprehensive installation and assembly guide for Armstrong ACOUSTIBuilt® seamless acoustical ceiling and wall systems. Learn about product features, safety, design considerations, step-by-step installation, finishing, and system components for achieving superior acoustical performance.
Preview WOODWORKS Vector MicroPerf Acoustical Wood Ceilings Specification
Comprehensive specifications for Armstrong's WOODWORKS Vector MicroPerf acoustical wood ceiling panels and suspension systems, detailing product attributes, installation, quality assurance, and warranty for architectural applications.
Preview DynaMax Structural Aluminum Suspension System Technical Guide
Comprehensive technical guide for the DynaMax structural aluminum suspension system by Armstrong, detailing its application in data centers, components, installation, load data, seismic considerations, and compatibility with ceiling panels and integrated lighting solutions.
Preview Armstrong Mineral Fiber and Fiberglass Ceiling Systems Catalog
Explore Armstrong's comprehensive catalog of Mineral Fiber and Fiberglass ceiling solutions, featuring ACOUSTIBuilt™, ARMATUFF®, OPTIMA®, and many other high-performance acoustic and aesthetic ceiling tiles for commercial spaces.
Preview Armstrong Drop Ceiling Installation Overview: A Step-by-Step Guide
Learn how to install an Armstrong drop ceiling with this concise overview. Covers wall molding, main beams, cross tees, and ceiling panel installation for residential use. Features QuickHang™ hardware.
Preview Armstrong Infusions Light Transmission Rates | ASTM D1003-00 Data
Detailed light transmission rates for Armstrong Infusions products, including L*, a*, b*, Haze, and Y Total % Light Transmission, tested per ASTM D1003-00 using HunterLab ColorQuest XE Spectrophotometer.
Preview Armstrong 30-Year Limited Ceiling Systems Warranty
Details the 30-year limited warranty for Armstrong commercial ceiling panels and suspension systems, covering defects, sagging, warping, and microbial growth resistance. Outlines coverage, exclusions, and service procedures.