Linkplay Technology Inc. AMP003 WiiM Amp Ultra 2BABF-AMP003 2BABFAMP003 amp003
REPORT No.SZ25020263W02 TEST REPORT APPLICANT : Linkplay Technology Inc. PRODUCT NAME : WiiM Amp Ultra MODEL NAME : AMP003 BRAND NAME : WiiM FCC ID : 2BABF-AMP003 STANDARD(S) : 47 CFR Part 15 Subpart C RECEIPT DATE : 2025-03-19 TEST DATE : 2025-04-15 to 2025-05-09 ISSUE DATE : 2025-05-19 Edited by: Zeng Xiaoying (Rapporteur) Approved by: Shen Junsheng (Supervisor) NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 1 of 36 REPORT No.SZ25020263W02 DIRECTORY 1. Summary of Test Result 3 1.1. Testing Applied Standards 4 1.2. Test Equipment List 5 1.3. Measurement Uncertainty 7 1.4. Testing Laboratory7 2. General Description 8 2.1. Information of Applicant and Manufacturer 8 2.2. Information of EUT8 2.3. Channel List of EUT 9 2.4. Test Configuration of EUT 10 2.5. Test Conditions 10 2.6. Test Setup Layout Diagram 10 3. Test Results 13 3.1. Conducted Emission 13 3.2. Restricted Frequency Bands 14 3.3. Radiated Emission 15 Annex A Test Data and Result 17 Version 1.0 Change History Date 2025-05-19 Reason for change First edition MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 2 of 36 1. Summary of Test Result REPORT No.SZ25020263W02 No. Section 1 15.203 2 15.247(a) 15.247(h) 3 15.247(a) 4 ANSI C63.10 5 15.247(b) 6 15.247(b) 7 15.247(a) 8 15.247(a) 9 15.247(a) 10 15.247(d) 11 15.207 12 15.247(d) 13 15.209, Description Antenna Requirement Hopping Mechanism Number of Hopping Frequency Duty Cycle Maximum Peak Conducted Output Power Maximum Average Conducted Output Power 20dB Bandwidth Carrier Frequency Separation Time of Occupancy (Dwell time) Conducted Spurious Emission Conducted Emission Restricted Frequency Bands Radiated Test Date N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A May 09, 2025 Apr. 09, 2025 Apr. 23, 2025 Test Engineer N/A Result Method Determination /Remark N/ANote1 N/A N/A N/ANote1 N/A N/A N/ANote1 N/A N/A N/ANote1 N/A N/A N/ANote1 N/A N/A N/ANote1 N/A N/A N/ANote1 N/A N/A N/ANote1 N/A N/A N/ANote1 N/A N/A N/ANote1 N/A Fan Shengquan PASS No deviation Gao Jianrou PASS No deviation Gao Jianrou PASS No deviation MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 3 of 36 REPORT No.SZ25020263W02 15.247(d) Emission Note 1: The test results of all conducted test items please refer to the module FCC test report (Report No.: SZ24040154W02), which issued on Jul. 26, 2024. Note 2: The tests were performed according to the method of measurements prescribed in ANSI C63.10-2013, KDB 558074 D01 v05r02 and DA 00-075. Note 3: Additions to, deviation, or exclusions from the method shall be judged in the "method determination" column of add, deviate or exclude from the specific method shall be explained in the "Remark" of the above table. Note 4: When the test result is a critical value, we will use the measurement uncertainty give the judgment result based on the 95% confidence intervals. 1.1. Testing Applied Standards According to the specifications of the manufacturer, the EUT must comply with the requirements of the following standards: 47 CFR Part 15 Subpart C Radio Frequency Devices MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 4 of 36 1.2. Test Equipment List REPORT No.SZ25020263W02 1.2.1 Conducted Emission Test Equipment Equipment Serial No. Type Receiver MY56400093 N9038A LISN 8127449 Pulse Limiter (10dB) RF Coaxial Cable (DC-100MHz) VTSD 9561 FB #206 BNC NSLK 8127 VTSD 9561-F MRE04 Manufacturer KEYSIGHT Cal. Date Due Date 2025.01.06 2026.01.05 Schwarzbeck 2025.01.09 2026.01.08 Schwarzbeck 2024.05.30 2025.05.29 Qualwave 2024.07.02 2025.07.01 1.2.2 List of Software Used Description JS32-RE TS+ -[JS32-CE] Manufacturer Tonscend Tonscend Software Version 5.0.0 2.5.0.0 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 5 of 36 REPORT No.SZ25020263W02 1.2.3 Radiated Test Equipment Equipment Serial No. Signal Analyzer MY56060145 Test Antenna - BiLog 9163-519 Test Antenna Loop 1519-022 Test Antenna Horn 01774 Test Antenna BBHA9170 Horn #773 Preamplifier (10MHz-6GHz) 46732 Preamplifier (2GHz-18GHz) 61171/61172 Preamplifier (18GHz-40GHz) DS77209 Type N9020A VULB 9163 FMZB1519 BBHA 9120D BBHA9170 S10M100L38 02 S020180L32 03 DCLNA0118- 40C-S RF Coaxial Cable (DC-18GHz) MRE001 PE330 RF Coaxial Cable (DC-18GHz) RF Coaxial Cable (DC-18GHz) RF Coaxial Cable (DC-40GHz) RF Coaxial Cable (DC-40GHz) RF Coaxial Cable (DC-18GHz) Notch Filter Anechoic Chamber Anechoic Chamber MRE002 MRE003 22290045 22290046 22120181 N/A N/A N/A CLU18 CLU18 QA360-40KK-0.5 QA360-40KKF-2 QA500-18NN-5 WRCG-24002483.5-60SS 9m*6m*6m 9m*6m*6m Manufacturer Agilent Schwarzbeck Schwarzbeck Schwarzbeck Schwarzbeck LUCIX CORP. LUCIX CORP. Decentest Pasternack Pasternack Pasternack Qualwave Qualwave Qualwave Wainwright CRT CRT Cal. Date 2024.05.30 2024.06.22 2024.06.03 2024.06.22 2024.06.22 2024.05.30 2024.05.30 2024.05.30 2024.05.30 2024.05.30 2024.05.30 2024.07.03 2024.07.03 2024.07.03 N/A 2025.04.19 2022.11.30 Due Date 2025.05.29 2025.06.21 2025.06.02 2025.06.21 2025.06.21 2025.05.29 2025.05.29 2025.05.29 2025.05.29 2025.05.29 2025.05.29 2025.07.02 2025.07.02 2025.07.02 N/A 2028.04.18 2025.11.29 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 6 of 36 1.3. Measurement Uncertainty REPORT No.SZ25020263W02 Test Items Restricted Frequency Bands Radiated Emission Conducted Emission 1.4. Testing Laboratory Uncertainty ±5% ±2.95dB ±2.44dB Remark Confidence levels of 95% Confidence levels of 95% Confidence levels of 95% Laboratory Name Laboratory Address Telephone Facsimile FCC Designation Number FCC Test Firm Registration Number Shenzhen Morlab Communications Technology Co., Ltd. FL.3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China +86 755 36698555 +86 755 36698525 CN1192 226174 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 7 of 36 2. General Description REPORT No.SZ25020263W02 2.1. Information of Applicant and Manufacturer Applicant Applicant Address Manufacturer Manufacturer Address Linkplay Technology Inc. 8000 Jarvis Avenue Suite #130, Newark, CA 94560 Linkplay Technology Inc. 8000 Jarvis Avenue Suite #130, Newark, CA 94560 2.2. Information of EUT Product Name: WiiM Amp Ultra Sample No.: 4#, 25# Hardware Version: A98D V02+Main Board V02 Software Version: Linkplay.5.2.708867 Equipment Type: Bluetooth classic Bluetooth Version: 5.3 Modulation Type: FHSS (GFSK(1Mbps), /4-DQPSK(EDR 2Mbps), 8-DPSK(EDR 3Mbps)) Operating Frequency Range: 2402MHz-2480MHz Antenna Type: PIFA Antenna Antenna Gain: ANT1: 3.46dBi; ANT2: 3.46dBi Note 1: The test results of all conducted test items please refer to the module FCC test report (Report No.: SZ24040154W02), which issued on Jul. 26, 2024. We only recorded the radiated test result in this report. Note 2: The EUT has two antennas and it operates in single antenna. Both of the two antennas were evaluated separately, only the worst test result (ANT2) were recorded in the test report. Note 3: We use the dedicated software to control the EUT continuous transmission. Note 4: For a more detailed description, please refer to Specification or User's Manual supplied by the applicant and/or manufacturer. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 8 of 36 2.3. Channel List of EUT REPORT No.SZ25020263W02 Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) 0 2402 20 2422 40 2442 60 2462 1 2403 21 2423 41 2443 61 2463 2 2404 22 2424 42 2444 62 2464 3 2405 23 2425 43 2445 63 2465 4 2406 24 2426 44 2446 64 2466 5 2407 25 2427 45 2447 65 2467 6 2408 26 2428 46 2448 66 2468 7 2409 27 2429 47 2449 67 2469 8 2410 28 2430 48 2450 68 2470 9 2411 29 2431 49 2451 69 2471 10 2412 30 2432 50 2452 70 2472 11 2413 31 2433 51 2453 71 2473 12 2414 32 2434 52 2454 72 2474 13 2415 33 2435 53 2455 73 2475 14 2416 34 2436 54 2456 74 2476 15 2417 35 2437 55 2457 75 2477 16 2418 36 2438 56 2458 76 2478 17 2419 37 2439 57 2459 77 2479 18 2420 38 2440 58 2460 78 2480 19 2421 39 2441 59 2461 Note 1: The black bold channels were selected for test. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 9 of 36 2.4. Test Configuration of EUT REPORT No.SZ25020263W02 Test mode is used to control the EUT under the maximum power level during test. 2.5. Test Conditions Temperature (°C) Relative Humidity (%) Atmospheric Pressure (kPa) 1535 3060 86106 2.6. Test Setup Layout Diagram 2.6.1.Conducted Emission Measurement MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 10 of 36 2.6.2.Radiation Measurement 1) For radiated emissions from 9kHz to 30MHz REPORT No.SZ25020263W02 2) For radiated emissions from 30MHz to1GHz MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 11 of 36 3) For radiated emissions above 1GHz REPORT No.SZ25020263W02 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 12 of 36 3. Test Results REPORT No.SZ25020263W02 3.1. Conducted Emission 3.1.1.Requirement According to FCC section 15.207, for an intentional radiator that is designed to be connected to the public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in the following table, as measured using a 50µH/50 line impedance stabilization network (LISN). Frequency Range (MHz) Conducted Limit (dBµV) Quai-peak Average 0.15 - 0.50 66 to 56 56 to 46 0.50 - 5 56 46 5 - 30 60 50 Note: (a) The lower limit shall apply at the band edges. (b) The limit decreases linearly with the logarithm of the frequency in the range 0.15 - 0.50MHz. 3.1.2.Test Procedures The Table-top EUT was placed upon a non-metallic table 0.8m above the horizontal metal reference ground plane. EUT was connected to LISN and LISN was connected to reference Ground Plane. EUT was 80cm from LISN. The set-up and test methods were according to ANSI C63.10: 2013. 3.1.3.Test Setup Layout Refer to chapter 2.6.2 in this report. 3.1.4.Test Result Refer to Annex A.1 in this report. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 13 of 36 3.2. Restricted Frequency Bands REPORT No.SZ25020263W02 3.2.1.Requirement According to FCC section 15.247(d), in any 100kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20dB below that in the 100kHz bandwidth within the band that contains the highest level of the desired power, In addition, radiated emissions which fall in the restricted bands, as defined in 15.205(a), must also comply with the radiated emission limits specified in 15.209(a). 3.2.2.Test Procedures The EUT is located in a 3m Semi-Anechoic Chamber; the antenna factors, cable loss and so on of the site as factors are calculated to correct the reading. For the Test Antenna: Test Antenna is 3m away from the EUT. Test Antenna height is varied from 1m to 4m above the ground to determine the maximum value of the field strength. Span = wide enough to fully capture the emission being measured RBW = 1 MHz for f 1GHz, 100 kHz for f < 1GHz VBW = 3 MHz Sweep = auto Detector function = peak/average Trace = max hold Allow the trace to stabilize 3.2.3.Test Setup Layout Refer to chapter 2.6.3 in this report. 3.2.4.Test Result Refer to Annex A.2 in this report. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 14 of 36 3.3. Radiated Emission REPORT No.SZ25020263W02 3.3.1.Requirement According to FCC section 15.247(d), radiated emission outside the frequency band attenuation below the general limits specified in FCC section 15.209(a) is not required. In addition, radiated emissions which fall in the restricted bands, as defined in FCC section 15.205(a), must also comply with the radiated emission limits specified in FCC section 15.209(a). According to FCC section 15.209 (a), except as provided elsewhere in this subpart, the emissions from an intentional radiator shall not exceed the field strength levels specified in the following table: Frequency (MHz) Field Strength (µV/m) Measurement Distance (m) 0.009 - 0.490 2400/F(kHz) 300 0.490 - 1.705 24000/F(kHz) 30 1.705 - 30.0 30 30 30 - 88 100 3 88 - 216 150 3 216 - 960 200 3 Above 960 500 3 Note1: For above 1000MHz, the emission limit in this paragraph is based on measurement instrumentation employing an average detector, measurement using instrumentation with a peak detector function, corresponding to 20dB above the maximum permitted average limit. Note2:For above 1000MHz, limit field strength of harmonics: 54dBuV/m@3m (AV) and 74dBuV/m@3m (PK).In addition, radiated emissions which fall in the restricted bands, as defined in Section 15.205(a), also should comply with the radiated emission limits specified in Section 15.209(a)(above table). MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 15 of 36 REPORT No.SZ25020263W02 3.3.2.Test Procedures The EUT is placed on a non-conducting table 80 cm above the ground plane for measurement below 1GHz; 1.5 m above the ground plane for measurement above 1GHz.The antenna to EUT distance is 3meters. The EUT is configured in accordance with ANSI C63.10. The EUT is set to transmit in a continuous mode. For measurements below 30MHz, the emission limits shown in the above table are based on measurements employing a CISPR quasi-peak detector except for the frequency bands 9kHz-90 kHz, 110kHz-490 kHz. Radiated emission limits in these two bands are based on measurements employing an average detector. For measurements below 1GHz the resolution bandwidth is set to 100kHz for peak detection measurements or 120kHz for quasi-peak detection measurements. Peak detection is used unless otherwise noted as quasi-peak. For measurements above 1GHz the resolution bandwidth is set to 1MHz, the video band width is set to 3MHz for peak measurements and as applicable for average measurements. The EUT is rotated through 360 degrees to maximize emissions received. The antenna is scanned from 1 to 4 meters above the ground plane to further maximize the emission. Measurements are made with the antenna polarized in both the vertical and the horizontal positions. For measurements above 1 GHz, keeping the measurement antenna aimed at the source of emissions at each frequency of significant emissions, with polarization oriented for maximum response. 3.3.3.Test Setup Layout Refer to chapter 2.6.3 in this report. 3.3.4.Test Result Refer to Annex A.3 in this report. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 16 of 36 REPORT No.SZ25020263W02 Annex A Test Data and Result A.1. Conducted Emission The maximum conducted interference is searched using Peak (PK), if the emission levels more than the AV and QP limits, and that have narrow margins from the AV and QP limits will be remeasured with AV and QP detectors. Tests for both L phase and N phase lines of the power mains connected to the EUT are performed. Set RBW=9kHz, VBW=30kHz. Refer to recorded points and plots below. Note: Both of the test voltage AC 120V/60Hz and AC 230V/50Hz were considered and tested respectively, only the results of the worst case AC 120V/60Hz were recorded in this report. A. Test Setup: Test Mode: EUT+TV+HDMl cable+Load+Fiber box+Mobile phone+Audio+U disk+BT TX Test voltage: AC 120V/60Hz The measurement results are obtained as below: E [dBV] =UR + LCable loss [dB] + AFactor UR: Receiver Reading AFactor: Voltage division factor of LISN MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 17 of 36 B. Test Plot: REPORT No.SZ25020263W02 (L Phase) No. Fre. (MHz) Emission Level (dBµV) Quai-peak Average 1 0.1815 44.37 27.97 2 0.3030 42.26 27.17 3 0.3750 46.72 27.64 4 0.4245 43.32 26.62 5 0.5595 34.46 22.39 6 3.6152 27.34 17.45 Limit (dBµV) Quai-peak 64.42 60.16 58.39 57.36 56.00 56.00 Average 54.42 50.16 48.39 47.36 46.00 46.00 Power-line Verdict PASS PASS Line PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 18 of 36 REPORT No.SZ25020263W02 (N Phase) No. Fre. (MHz) Emission Level (dBµV) Quai-peak Average 1 0.2175 44.17 28.40 2 0.3525 43.11 26.32 3 0.4875 31.51 23.76 4 0.7666 28.42 20.29 5 3.4077 29.35 20.52 6 9.9915 39.24 23.80 Limit (dBµV) Quai-peak 62.91 58.90 56.21 56.00 56.00 60.00 Average 52.91 48.90 46.21 46.00 46.00 50.00 Power-line Verdict Neutral PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 19 of 36 REPORT No.SZ25020263W02 A.2. Restricted Frequency Bands Note 1: Restricted Frequency Bands were performed when antenna was at vertical and horizontal polarity, and only the worse test condition (Horizontal) was recorded in this test report. Note 2: All test modes were considered and evaluated respectively by performing full test, only the worst data were recorded. GFSK Mode Plot for Channel 0 Fre. (MHz) 2324.81 2326.02 2352.34 2367.16 2374.56 2375.07 Reading [dBV] 11.9 -0.4 -0.3 13.4 12.7 0.4 Level [dBV/m] 44.03 31.77 32.06 45.83 45.19 32.92 Factor [dB/m] 32.160 32.170 32.400 32.460 32.490 32.490 Limit [dBV/m] 74.00 54.00 54.00 74.00 74.00 54.00 Margin [dB] 29.97 22.23 21.94 28.17 28.81 21.08 Height [cm] 150 150 150 150 150 150 Angle [°] 340 11 360 293 331 11 Detector PK AV AV PK PK AV Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 20 of 36 Plot for Channel 78 REPORT No.SZ25020263W02 Fre. (MHz) 2484.07 2485.01 2488.71 2489.08 2494.77 2495.45 Reading [dBV] 5.6 17.8 5.5 17.5 5.6 18.1 Level [dBV/m] 38.67 50.82 38.47 50.51 38.56 51.06 Factor [dB/m] 33.030 33.030 33.020 33.020 33.010 33.010 Limit [dBV/m] 54.00 74.00 54.00 74.00 54.00 74.00 Margin [dB] 15.33 23.18 15.53 23.49 15.44 22.94 Height [cm] 150 150 150 150 150 150 Angle [°] 144 236 144 172 337 204 Detector AV PK AV PK AV PK Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 21 of 36 8-DPSK Mode Plot for Channel 0 REPORT No.SZ25020263W02 Fre. (MHz) 2319.71 2352.44 2375.17 2375.27 2383.17 2385.88 Reading [dBV] -0.2 -0.3 0.4 12.8 13.1 12.8 Level [dBV/m] 31.88 32.13 32.93 45.28 45.57 45.36 Factor [dB/m] 32.110 32.400 32.490 32.490 32.520 32.530 Limit [dBV/m] 54.00 54.00 54.00 74.00 74.00 74.00 Margin [dB] 22.12 21.87 21.07 28.72 28.43 28.64 Height [cm] 150 150 150 150 150 150 Angle [°] 243 105 48 310 0 77 Detector AV AV AV PK PK PK Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 22 of 36 Plot for Channel 78 REPORT No.SZ25020263W02 Fre. (MHz) 2484.63 2484.85 2487.54 2490.11 2492.86 2493.46 Reading [dBV] 5.7 18.0 5.5 17.6 5.4 18.8 Level [dBV/m] 38.74 51.06 38.51 50.62 38.45 51.81 Factor [dB/m] 33.030 33.030 33.020 33.020 33.010 33.010 Limit [dBV/m] 54.00 74.00 54.00 74.00 54.00 74.00 Margin [dB] 15.26 22.94 15.49 23.38 15.55 22.19 Height [cm] 150 150 150 150 150 150 Angle [°] 177 0 108 279 350 258 Detector AV PK AV PK AV PK Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 23 of 36 REPORT No.SZ25020263W02 A.3. Radiated Emission According to ANSI C63.10, because of peak detection will yield amplitudes equal to or greater than amplitudes measured with the quasi-peak (or average) detector, the measurement data from a spectrum analyzer peak detector will represent the worst-case results, if the peak measured value complies with the quasi-peak (or average) limit, it is unnecessary to perform an quasi-peak measurement (or average). The measurement results are obtained as below: E [dBV/m] =UR + AT + AFactor [dB]; AT =LCable loss [dB]-Gpreamp [dB] AT: Total correction Factor except Antenna UR: Receiver Reading Gpreamp: Preamplifier Gain AFactor: Antenna Factor at 3m During the test, the total correction Factor AT and AFactor were built in test software. Note1: All radiated emission tests were performed in X, Y, Z axis direction. And only the worst axis test condition was recorded in this test report. Note2: For the frequency, which started from 9kHz to 30MHz, was pre-scanned and the result which was 20dB lower than the limit was not recorded. Note3: For the frequency, which started from 18GHz to 10th harmonic of the highest frequency, was pre-scanned and the result which was 20dB lower than the limit was not recorded. Note 4: All test modes were considered and evaluated respectively by performing full test, only the worst data were recorded. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 24 of 36 GFSK Mode Plot for Channel 0 REPORT No.SZ25020263W02 Fre. (MHz) 55.90 104.74 163.92 250.01 531.52 750.02 (Antenna Horizontal, 30MHz to 1GHz) Reading [dBV] 61.1 67.3 67.5 68.4 52.8 47.5 Level [dBV/m] 33.07 38.02 36.49 40.93 33.81 32.68 Factor [dB/m] -28.020 -29.300 -31.050 -27.490 -18.950 -14.840 Limit [dBV/m] 40.00 43.50 43.50 46.00 46.00 46.00 Margin [dB] 6.93 5.48 7.01 5.07 12.19 13.32 Height [cm] 150 150 150 150 150 150 Angle [°] 330 302 188 351 139 266 Detector PK PK PK PK PK PK Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 25 of 36 REPORT No.SZ25020263W02 (Antenna Horizontal, 1GHz to 18GHz) Fre. (MHz) 1596.52 1596.92 2469.89 2470.29 3202.72 3203.15 5113.35 5123.63 11102.37 11117.37 14616.76 14729.91 Reading [dBV] 43.4 33.4 28.3 40.4 54.0 50.4 47.4 37.2 30.4 39.3 27.2 36.0 Level [dBV/m] 43.00 32.99 34.17 46.29 43.09 39.50 44.27 34.20 44.45 53.24 47.61 56.32 Factor [dB/m] -0.420 -0.420 5.920 5.920 -10.880 -10.880 -3.130 -2.960 14.070 13.970 20.380 20.340 Limit [dBV/m] 74.00 54.00 54.00 74.00 74.00 54.00 74.00 54.00 54.00 74.00 54.00 74.00 Margin [dB] 31.00 21.01 19.83 27.71 30.91 14.50 29.73 19.80 9.55 20.76 6.39 17.68 Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150 Angle [°] 39 39 214 50 104 104 239 64 130 171 280 358 Detector PK AV AV PK PK AV PK AV AV PK AV PK Verdict PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 26 of 36 REPORT No.SZ25020263W02 Fre. (MHz) 30.63 54.15 104.74 164.50 282.60 749.97 (Antenna Vertical, 30MHz to 1GHz) Reading [dBV] 65.7 62.2 63.0 63.7 60.9 49.7 Level [dBV/m] 34.92 34.61 33.70 32.51 34.57 34.89 Factor [dB/m] -30.750 -27.590 -29.300 -31.220 -26.310 -14.840 Limit [dBV/m] 40.00 40.00 43.50 43.50 46.00 46.00 Margin [dB] 5.08 5.39 9.80 10.99 11.43 11.11 Height [cm] 150 150 150 150 150 150 Angle [°] 188 300 125 40 245 188 Detector PK PK PK PK PK PK Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 27 of 36 REPORT No.SZ25020263W02 (Antenna Vertical, 1GHz to 18GHz) Fre. (MHz) 1658.13 1663.33 2402.28 2475.50 3202.72 3203.15 7049.26 7173.98 11104.52 11480.39 14674.19 14683.19 Reading [dBV] 32.3 44.2 30.7 40.2 58.3 56.4 44.7 35.1 39.1 29.7 35.8 26.4 Level [dBV/m] 32.29 44.18 35.93 46.10 47.43 45.50 49.06 39.99 53.20 43.95 56.34 46.99 Factor [dB/m] -0.010 0.020 5.250 5.910 -10.880 -10.880 4.350 4.850 14.060 14.230 20.530 20.560 Limit [dBV/m] 54.00 74.00 54.00 74.00 74.00 54.00 74.00 54.00 74.00 54.00 74.00 54.00 Margin [dB] 21.71 29.82 18.07 27.90 26.57 8.50 24.94 14.01 20.80 10.05 17.66 7.01 Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150 Angle [°] 133 133 143 105 144 144 64 144 185 211 331 265 Detector AV PK AV PK PK AV PK AV PK AV PK AV Verdict PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 28 of 36 Plot for Channel 39 REPORT No.SZ25020263W02 Fre. (MHz) 55.85 104.74 163.96 264.02 331.78 750.02 (Antenna Horizontal, 30MHz to 1GHz) Reading [dBV] 61.7 67.8 66.6 62.9 58.8 46.2 Level [dBV/m] 33.68 38.53 35.54 35.32 34.42 31.40 Factor [dB/m] -28.010 -29.300 -31.040 -27.550 -24.390 -14.840 Limit [dBV/m] 40.00 43.50 43.50 46.00 46.00 46.00 Margin [dB] 6.32 4.97 7.96 10.68 11.58 14.60 Height [cm] 150 150 150 150 150 150 Angle [°] 358 313 171 9 178 236 Detector PK PK PK PK PK PK Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 29 of 36 REPORT No.SZ25020263W02 (Antenna Horizontal, 1GHz to 18GHz) Fre. (MHz) 1047.61 1066.41 2414.28 2441.49 3254.58 7173.12 7200.98 10700.79 11505.24 14542.19 14733.76 Reading [dBV] 35.0 48.3 39.9 32.5 52.5 44.1 34.3 31.0 39.0 36.5 27.2 Level [dBV/m] 32.21 45.69 45.33 38.37 41.15 48.94 39.39 43.42 53.24 56.49 47.50 Factor [dB/m] -2.760 -2.600 5.430 5.840 -11.300 4.840 5.110 12.450 14.280 20.030 20.310 Limit [dBV/m] 54.00 74.00 74.00 74.00 74.00 54.00 54.00 74.00 74.00 54.00 Margin [dB] 21.79 28.31 28.67 32.85 25.06 14.61 10.58 20.76 17.51 6.50 Height [cm] 150 150 150 150 150 150 150 150 150 150 150 Angle [°] 351 19 177 231 306 64 117 130 130 64 360 Detector AV PK PK AV PK PK AV AV PK PK AV Verdict PASS PASS PASS NA PASS PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 30 of 36 REPORT No.SZ25020263W02 Fre. (MHz) 30.58 51.63 98.44 199.95 282.60 750.02 (Antenna Vertical, 30MHz to 1GHz) Reading [dBV] 66.9 63.1 63.6 62.4 60.8 48.4 Level [dBV/m] 36.10 35.13 33.91 33.63 34.49 33.51 Factor [dB/m] -30.750 -28.010 -29.690 -28.780 -26.310 -14.840 Limit [dBV/m] 40.00 40.00 43.50 43.50 46.00 46.00 Margin [dB] 3.90 4.87 9.59 9.87 11.51 12.49 Height [cm] 150 150 150 150 150 150 Angle [°] 130 345 186 45 258 115 Detector PK PK PK PK PK PK Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 31 of 36 REPORT No.SZ25020263W02 (Antenna Vertical, 1GHz to 18GHz) Fre. (MHz) 1648.13 1670.93 2440.69 2441.49 3254.58 3255.01 6396.10 6396.53 10614.65 10636.50 14448.33 14669.48 Reading [dBV] 44.2 31.6 41.2 39.0 57.2 55.6 48.4 38.8 41.5 31.3 27.4 35.5 Level [dBV/m] 44.08 31.62 47.01 44.85 45.85 44.33 49.39 39.83 53.65 43.49 46.60 55.97 Factor [dB/m] -0.080 0.060 5.830 5.840 -11.300 -11.300 1.010 1.010 12.140 12.230 19.220 20.520 Limit [dBV/m] 74.00 54.00 74.00 54.00 74.00 54.00 74.00 54.00 54.00 74.00 Margin [dB] 29.92 22.38 28.15 9.67 24.61 14.17 20.35 10.51 7.40 18.03 Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150 Angle [°] 150 128 155 155 146 146 9 9 267 348 37 187 Detector PK AV PK AV PK AV PK AV PK AV AV PK Verdict PASS PASS NA NA PASS PASS PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 32 of 36 Plot for Channel 78 REPORT No.SZ25020263W02 Fre. (MHz) 55.90 104.74 163.96 264.56 530.93 750.02 (Antenna Horizontal, 30MHz to 1GHz) Reading [dBV] 62.3 67.6 67.7 62.3 48.8 44.0 Level [dBV/m] 34.23 38.29 36.64 34.85 29.85 29.13 Factor [dB/m] -28.020 -29.300 -31.040 -27.480 -18.930 -14.840 Limit [dBV/m] 40.00 43.50 43.50 46.00 46.00 46.00 Margin [dB] 5.77 5.21 6.86 11.15 16.15 16.87 Height [cm] 150 150 150 150 150 150 Angle [°] 344 324 190 1 324 217 Detector PK PK PK PK PK PK Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 33 of 36 REPORT No.SZ25020263W02 (Antenna Horizontal, 1GHz to 18GHz) Fre. (MHz) 1069.21 1069.61 3306.44 3306.87 5214.06 5214.92 6777.54 6782.25 11099.37 11147.80 14521.61 14687.48 Reading [dBV] 47.1 34.7 50.1 45.7 47.7 40.6 45.9 35.6 39.8 30.3 27.3 36.0 Level [dBV/m] 44.55 32.11 39.13 34.71 44.29 37.23 49.77 39.42 53.85 44.12 47.24 56.52 Factor [dB/m] -2.580 -2.580 -11.000 -11.000 -3.420 -3.410 3.900 3.870 14.070 13.790 19.920 20.570 Limit [dBV/m] 74.00 54.00 74.00 54.00 74.00 54.00 74.00 54.00 74.00 54.00 54.00 74.00 Margin [dB] 29.45 21.89 34.87 19.29 29.71 16.77 24.23 14.58 20.15 9.88 6.76 17.48 Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150 Angle [°] 18 24 332 332 9 9 360 251 104 319 9 332 Detector PK AV PK AV PK AV PK AV PK AV AV PK Verdict PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 34 of 36 REPORT No.SZ25020263W02 Fre. (MHz) 30.63 62.45 81.22 184.33 282.60 750.02 (Antenna Vertical, 30MHz to 1GHz) Reading [dBV] 65.2 64.4 65.7 63.5 60.8 44.0 Level [dBV/m] 34.48 35.66 33.59 33.39 34.44 29.13 Factor [dB/m] -30.750 -28.750 -32.060 -30.090 -26.310 -14.840 Limit [dBV/m] 40.00 40.00 40.00 43.50 46.00 46.00 Margin [dB] 5.52 4.34 6.41 10.11 11.56 16.87 Height [cm] 150 150 150 150 150 150 Angle [°] 147 110 54 230 265 68 Detector PK PK PK PK PK PK Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 35 of 36 REPORT No.SZ25020263W02 (Antenna Vertical, 1GHz to 18GHz) Fre. (MHz) 1111.62 1123.22 2470.29 2480.30 3306.87 3306.87 7203.98 7209.12 11091.23 11105.37 14693.91 14703.76 Reading [dBV] 32.8 44.1 39.5 31.8 47.9 51.8 44.2 34.5 39.7 30.2 35.6 27.2 Level [dBV/m] 30.58 41.97 45.44 37.69 36.90 40.82 49.26 39.51 53.66 44.28 56.13 47.73 Factor [dB/m] -2.260 -2.160 5.920 5.890 -11.000 -11.000 5.060 4.980 13.970 14.040 20.580 20.570 Limit [dBV/m] 54.00 74.00 74.00 54.00 74.00 74.00 54.00 74.00 54.00 74.00 54.00 Margin [dB] 23.42 32.03 28.56 17.10 33.18 24.74 14.49 20.34 9.72 17.87 6.27 Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150 Angle [°] 138 133 231 149 63 171 347 63 292 212 89 332 Detector AV PK PK AV AV PK PK AV PK AV PK AV Verdict PASS PASS PASS NA PASS PASS PASS PASS PASS PASS PASS PASS END OF REPORT MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 36 of 36Acrobat Distiller 9.3.2 (Windows)