SZ25020263W02 Linkplay AMP003 BTclassic DSS

Morlab

SZ25020263W02 Linkplay AMP003 BTclassic DSS

Linkplay Technology Inc. AMP003 WiiM Amp Ultra 2BABF-AMP003 2BABFAMP003 amp003

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=8316405
REPORT No.SZ25020263W02
TEST REPORT

APPLICANT

: Linkplay Technology Inc.

PRODUCT NAME : WiiM Amp Ultra

MODEL NAME

: AMP003

BRAND NAME

: WiiM

FCC ID

: 2BABF-AMP003

STANDARD(S)

: 47 CFR Part 15 Subpart C

RECEIPT DATE

: 2025-03-19

TEST DATE

: 2025-04-15 to 2025-05-09

ISSUE DATE

: 2025-05-19

Edited by:

Zeng Xiaoying (Rapporteur)

Approved by: Shen Junsheng (Supervisor)

NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn

Page 1 of 36

REPORT No.SZ25020263W02
DIRECTORY
1. Summary of Test Result 3 1.1. Testing Applied Standards 4 1.2. Test Equipment List 5 1.3. Measurement Uncertainty 7 1.4. Testing Laboratory7 2. General Description 8 2.1. Information of Applicant and Manufacturer 8 2.2. Information of EUT8 2.3. Channel List of EUT 9 2.4. Test Configuration of EUT 10 2.5. Test Conditions  10 2.6. Test Setup Layout Diagram  10 3. Test Results  13 3.1. Conducted Emission  13 3.2. Restricted Frequency Bands  14 3.3. Radiated Emission  15 Annex A Test Data and Result  17

Version 1.0

Change History Date 2025-05-19

Reason for change First edition

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 2 of 36

1. Summary of Test Result

REPORT No.SZ25020263W02

No. Section

1 15.203

2

15.247(a) 15.247(h)

3 15.247(a)

4

ANSI C63.10

5 15.247(b)

6 15.247(b) 7 15.247(a) 8 15.247(a) 9 15.247(a) 10 15.247(d) 11 15.207 12 15.247(d) 13 15.209,

Description
Antenna Requirement Hopping Mechanism Number of Hopping Frequency
Duty Cycle
Maximum Peak Conducted Output Power Maximum Average Conducted Output Power 20dB Bandwidth Carrier Frequency Separation Time of Occupancy (Dwell time) Conducted Spurious Emission Conducted Emission Restricted Frequency Bands Radiated

Test Date N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A May 09, 2025 Apr. 09, 2025 Apr. 23, 2025

Test Engineer
N/A

Result

Method Determination
/Remark

N/ANote1

N/A

N/A

N/ANote1

N/A

N/A

N/ANote1

N/A

N/A

N/ANote1

N/A

N/A

N/ANote1

N/A

N/A

N/ANote1

N/A

N/A

N/ANote1

N/A

N/A

N/ANote1

N/A

N/A

N/ANote1

N/A

N/A

N/ANote1

N/A

Fan Shengquan

PASS

No deviation

Gao Jianrou PASS No deviation

Gao Jianrou PASS No deviation

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 3 of 36

REPORT No.SZ25020263W02
15.247(d) Emission Note 1: The test results of all conducted test items please refer to the module FCC test report (Report No.: SZ24040154W02), which issued on Jul. 26, 2024. Note 2: The tests were performed according to the method of measurements prescribed in ANSI C63.10-2013, KDB 558074 D01 v05r02 and DA 00-075. Note 3: Additions to, deviation, or exclusions from the method shall be judged in the "method determination" column of add, deviate or exclude from the specific method shall be explained in the "Remark" of the above table. Note 4: When the test result is a critical value, we will use the measurement uncertainty give the judgment result based on the 95% confidence intervals.
1.1. Testing Applied Standards
According to the specifications of the manufacturer, the EUT must comply with the requirements of the following standards:  47 CFR Part 15 Subpart C Radio Frequency Devices

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 4 of 36

1.2. Test Equipment List

REPORT No.SZ25020263W02

1.2.1 Conducted Emission Test Equipment

Equipment

Serial No.

Type

Receiver

MY56400093 N9038A

LISN

8127449

Pulse Limiter (10dB)
RF Coaxial Cable (DC-100MHz)

VTSD 9561 FB #206
BNC

NSLK 8127 VTSD 9561-F
MRE04

Manufacturer KEYSIGHT

Cal. Date Due Date 2025.01.06 2026.01.05

Schwarzbeck 2025.01.09 2026.01.08

Schwarzbeck 2024.05.30 2025.05.29

Qualwave

2024.07.02 2025.07.01

1.2.2 List of Software Used Description JS32-RE
TS+ -[JS32-CE]

Manufacturer Tonscend Tonscend

Software Version 5.0.0 2.5.0.0

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 5 of 36

REPORT No.SZ25020263W02

1.2.3 Radiated Test Equipment

Equipment

Serial No.

Signal Analyzer MY56060145

Test Antenna - BiLog

9163-519

Test Antenna Loop

1519-022

Test Antenna ­ Horn

01774

Test Antenna ­ BBHA9170

Horn

#773

Preamplifier (10MHz-6GHz)

46732

Preamplifier (2GHz-18GHz)

61171/61172

Preamplifier (18GHz-40GHz)

DS77209

Type N9020A VULB 9163
FMZB1519
BBHA 9120D
BBHA9170 S10M100L38
02 S020180L32
03 DCLNA0118-
40C-S

RF Coaxial Cable (DC-18GHz)

MRE001

PE330

RF Coaxial Cable (DC-18GHz)
RF Coaxial Cable (DC-18GHz)
RF Coaxial Cable (DC-40GHz)
RF Coaxial Cable (DC-40GHz)
RF Coaxial Cable (DC-18GHz)
Notch Filter
Anechoic Chamber Anechoic Chamber

MRE002 MRE003 22290045 22290046 22120181
N/A N/A N/A

CLU18
CLU18
QA360-40KK-0.5
QA360-40KKF-2
QA500-18NN-5
WRCG-24002483.5-60SS
9m*6m*6m
9m*6m*6m

Manufacturer Agilent
Schwarzbeck Schwarzbeck Schwarzbeck Schwarzbeck LUCIX CORP. LUCIX CORP.
Decentest
Pasternack
Pasternack Pasternack Qualwave Qualwave Qualwave Wainwright
CRT CRT

Cal. Date 2024.05.30 2024.06.22 2024.06.03 2024.06.22 2024.06.22 2024.05.30 2024.05.30 2024.05.30
2024.05.30
2024.05.30 2024.05.30 2024.07.03 2024.07.03 2024.07.03
N/A 2025.04.19 2022.11.30

Due Date 2025.05.29 2025.06.21 2025.06.02 2025.06.21 2025.06.21 2025.05.29 2025.05.29 2025.05.29
2025.05.29
2025.05.29 2025.05.29 2025.07.02 2025.07.02 2025.07.02
N/A 2028.04.18 2025.11.29

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 6 of 36

1.3. Measurement Uncertainty

REPORT No.SZ25020263W02

Test Items Restricted Frequency Bands Radiated Emission Conducted Emission
1.4. Testing Laboratory

Uncertainty ±5% ±2.95dB ±2.44dB

Remark Confidence levels of 95% Confidence levels of 95% Confidence levels of 95%

Laboratory Name
Laboratory Address
Telephone Facsimile FCC Designation Number FCC Test Firm Registration Number

Shenzhen Morlab Communications Technology Co., Ltd. FL.3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China +86 755 36698555 +86 755 36698525 CN1192
226174

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 7 of 36

2. General Description

REPORT No.SZ25020263W02

2.1. Information of Applicant and Manufacturer

Applicant Applicant Address Manufacturer Manufacturer Address

Linkplay Technology Inc. 8000 Jarvis Avenue Suite #130, Newark, CA 94560 Linkplay Technology Inc. 8000 Jarvis Avenue Suite #130, Newark, CA 94560

2.2. Information of EUT

Product Name:

WiiM Amp Ultra

Sample No.:

4#, 25#

Hardware Version:

A98D V02+Main Board V02

Software Version:

Linkplay.5.2.708867

Equipment Type:

Bluetooth classic

Bluetooth Version:

5.3

Modulation Type:

FHSS (GFSK(1Mbps), /4-DQPSK(EDR 2Mbps), 8-DPSK(EDR 3Mbps))

Operating Frequency Range: 2402MHz-2480MHz

Antenna Type:

PIFA Antenna

Antenna Gain:

ANT1: 3.46dBi; ANT2: 3.46dBi

Note 1: The test results of all conducted test items please refer to the module FCC test report (Report No.: SZ24040154W02), which issued on Jul. 26, 2024. We only recorded the radiated test

result in this report.

Note 2: The EUT has two antennas and it operates in single antenna. Both of the two antennas

were evaluated separately, only the worst test result (ANT2) were recorded in the test report.

Note 3: We use the dedicated software to control the EUT continuous transmission.

Note 4: For a more detailed description, please refer to Specification or User's Manual supplied by

the applicant and/or manufacturer.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 8 of 36

2.3. Channel List of EUT

REPORT No.SZ25020263W02

Channel

Frequency (MHz)

Channel

Frequency (MHz)

Channel

Frequency (MHz)

Channel

Frequency (MHz)

0

2402

20

2422

40

2442

60

2462

1

2403

21

2423

41

2443

61

2463

2

2404

22

2424

42

2444

62

2464

3

2405

23

2425

43

2445

63

2465

4

2406

24

2426

44

2446

64

2466

5

2407

25

2427

45

2447

65

2467

6

2408

26

2428

46

2448

66

2468

7

2409

27

2429

47

2449

67

2469

8

2410

28

2430

48

2450

68

2470

9

2411

29

2431

49

2451

69

2471

10

2412

30

2432

50

2452

70

2472

11

2413

31

2433

51

2453

71

2473

12

2414

32

2434

52

2454

72

2474

13

2415

33

2435

53

2455

73

2475

14

2416

34

2436

54

2456

74

2476

15

2417

35

2437

55

2457

75

2477

16

2418

36

2438

56

2458

76

2478

17

2419

37

2439

57

2459

77

2479

18

2420

38

2440

58

2460

78

2480

19

2421

39

2441

59

2461

Note 1: The black bold channels were selected for test.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 9 of 36

2.4. Test Configuration of EUT

REPORT No.SZ25020263W02

Test mode is used to control the EUT under the maximum power level during test.
2.5. Test Conditions

Temperature (°C) Relative Humidity (%) Atmospheric Pressure (kPa)

15­35 30­60 86­106

2.6. Test Setup Layout Diagram

2.6.1.Conducted Emission Measurement

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 10 of 36

2.6.2.Radiation Measurement 1) For radiated emissions from 9kHz to 30MHz

REPORT No.SZ25020263W02

2) For radiated emissions from 30MHz to1GHz

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 11 of 36

3) For radiated emissions above 1GHz

REPORT No.SZ25020263W02

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 12 of 36

3. Test Results

REPORT No.SZ25020263W02

3.1. Conducted Emission

3.1.1.Requirement

According to FCC section 15.207, for an intentional radiator that is designed to be connected to the

public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power

line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in the following

table, as measured using a 50µH/50 line impedance stabilization network (LISN).

Frequency Range (MHz)

Conducted Limit (dBµV)

Quai-peak

Average

0.15 - 0.50

66 to 56

56 to 46

0.50 - 5

56

46

5 - 30

60

50

Note:

(a) The lower limit shall apply at the band edges.

(b) The limit decreases linearly with the logarithm of the frequency in the range 0.15 - 0.50MHz.

3.1.2.Test Procedures

The Table-top EUT was placed upon a non-metallic table 0.8m above the horizontal metal reference ground plane. EUT was connected to LISN and LISN was connected to reference Ground Plane. EUT was 80cm from LISN. The set-up and test methods were according to ANSI C63.10: 2013.

3.1.3.Test Setup Layout Refer to chapter 2.6.2 in this report.

3.1.4.Test Result Refer to Annex A.1 in this report.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 13 of 36

3.2. Restricted Frequency Bands

REPORT No.SZ25020263W02

3.2.1.Requirement
According to FCC section 15.247(d), in any 100kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20dB below that in the 100kHz bandwidth within the band that contains the highest level of the desired power, In addition, radiated emissions which fall in the restricted bands, as defined in 15.205(a), must also comply with the radiated emission limits specified in 15.209(a).

3.2.2.Test Procedures
The EUT is located in a 3m Semi-Anechoic Chamber; the antenna factors, cable loss and so on of the site as factors are calculated to correct the reading. For the Test Antenna: Test Antenna is 3m away from the EUT. Test Antenna height is varied from 1m to 4m above the ground to determine the maximum value of the field strength. Span = wide enough to fully capture the emission being measured RBW = 1 MHz for f  1GHz, 100 kHz for f < 1GHz VBW = 3 MHz Sweep = auto Detector function = peak/average Trace = max hold Allow the trace to stabilize

3.2.3.Test Setup Layout Refer to chapter 2.6.3 in this report.

3.2.4.Test Result Refer to Annex A.2 in this report.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 14 of 36

3.3. Radiated Emission

REPORT No.SZ25020263W02

3.3.1.Requirement

According to FCC section 15.247(d), radiated emission outside the frequency band attenuation below the general limits specified in FCC section 15.209(a) is not required. In addition, radiated emissions which fall in the restricted bands, as defined in FCC section 15.205(a), must also comply with the radiated emission limits specified in FCC section 15.209(a).

According to FCC section 15.209 (a), except as provided elsewhere in this subpart, the emissions

from an intentional radiator shall not exceed the field strength levels specified in the following

table:

Frequency (MHz)

Field Strength (µV/m)

Measurement Distance (m)

0.009 - 0.490

2400/F(kHz)

300

0.490 - 1.705

24000/F(kHz)

30

1.705 - 30.0

30

30

30 - 88

100

3

88 - 216

150

3

216 - 960

200

3

Above 960

500

3

Note1: For above 1000MHz, the emission limit in this paragraph is based on measurement

instrumentation employing an average detector, measurement using instrumentation with a peak

detector function, corresponding to 20dB above the maximum permitted average limit.

Note2:For above 1000MHz, limit field strength of harmonics: 54dBuV/m@3m (AV) and

74dBuV/m@3m (PK).In addition, radiated emissions which fall in the restricted bands, as defined

in Section 15.205(a), also should comply with the radiated emission limits specified in Section

15.209(a)(above table).

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 15 of 36

REPORT No.SZ25020263W02
3.3.2.Test Procedures
The EUT is placed on a non-conducting table 80 cm above the ground plane for measurement below 1GHz; 1.5 m above the ground plane for measurement above 1GHz.The antenna to EUT distance is 3meters. The EUT is configured in accordance with ANSI C63.10. The EUT is set to transmit in a continuous mode.
For measurements below 30MHz, the emission limits shown in the above table are based on measurements employing a CISPR quasi-peak detector except for the frequency bands 9kHz-90 kHz, 110kHz-490 kHz. Radiated emission limits in these two bands are based on measurements employing an average detector.
For measurements below 1GHz the resolution bandwidth is set to 100kHz for peak detection measurements or 120kHz for quasi-peak detection measurements. Peak detection is used unless otherwise noted as quasi-peak.
For measurements above 1GHz the resolution bandwidth is set to 1MHz, the video band width is set to 3MHz for peak measurements and as applicable for average measurements.
The EUT is rotated through 360 degrees to maximize emissions received. The antenna is scanned from 1 to 4 meters above the ground plane to further maximize the emission. Measurements are made with the antenna polarized in both the vertical and the horizontal positions. For measurements above 1 GHz, keeping the measurement antenna aimed at the source of emissions at each frequency of significant emissions, with polarization oriented for maximum response.
3.3.3.Test Setup Layout
Refer to chapter 2.6.3 in this report.
3.3.4.Test Result
Refer to Annex A.3 in this report.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 16 of 36

REPORT No.SZ25020263W02
Annex A Test Data and Result
A.1. Conducted Emission
The maximum conducted interference is searched using Peak (PK), if the emission levels more than the AV and QP limits, and that have narrow margins from the AV and QP limits will be remeasured with AV and QP detectors. Tests for both L phase and N phase lines of the power mains connected to the EUT are performed. Set RBW=9kHz, VBW=30kHz. Refer to recorded points and plots below. Note: Both of the test voltage AC 120V/60Hz and AC 230V/50Hz were considered and tested respectively, only the results of the worst case AC 120V/60Hz were recorded in this report. A. Test Setup: Test Mode: EUT+TV+HDMl cable+Load+Fiber box+Mobile phone+Audio+U disk+BT TX Test voltage: AC 120V/60Hz The measurement results are obtained as below: E [dBV] =UR + LCable loss [dB] + AFactor UR: Receiver Reading AFactor: Voltage division factor of LISN

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 17 of 36

B. Test Plot:

REPORT No.SZ25020263W02

(L Phase)

No.

Fre. (MHz)

Emission Level (dBµV) Quai-peak Average

1 0.1815

44.37

27.97

2 0.3030

42.26

27.17

3 0.3750

46.72

27.64

4 0.4245

43.32

26.62

5 0.5595

34.46

22.39

6 3.6152

27.34

17.45

Limit (dBµV)

Quai-peak 64.42 60.16 58.39 57.36 56.00 56.00

Average 54.42 50.16 48.39 47.36 46.00 46.00

Power-line Verdict

PASS

PASS

Line

PASS PASS

PASS

PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 18 of 36

REPORT No.SZ25020263W02

(N Phase)

No.

Fre. (MHz)

Emission Level (dBµV) Quai-peak Average

1 0.2175

44.17

28.40

2 0.3525

43.11

26.32

3 0.4875

31.51

23.76

4 0.7666

28.42

20.29

5 3.4077

29.35

20.52

6 9.9915

39.24

23.80

Limit (dBµV)

Quai-peak 62.91 58.90 56.21 56.00 56.00 60.00

Average 52.91 48.90 46.21 46.00 46.00 50.00

Power-line Verdict

Neutral

PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 19 of 36

REPORT No.SZ25020263W02
A.2. Restricted Frequency Bands
Note 1: Restricted Frequency Bands were performed when antenna was at vertical and horizontal polarity, and only the worse test condition (Horizontal) was recorded in this test report. Note 2: All test modes were considered and evaluated respectively by performing full test, only the worst data were recorded. GFSK Mode Plot for Channel 0

Fre. (MHz) 2324.81 2326.02 2352.34 2367.16 2374.56 2375.07

Reading [dBV]
11.9 -0.4 -0.3 13.4 12.7 0.4

Level [dBV/m]
44.03 31.77 32.06 45.83 45.19 32.92

Factor [dB/m] 32.160 32.170 32.400 32.460 32.490 32.490

Limit [dBV/m]
74.00 54.00 54.00 74.00 74.00 54.00

Margin [dB] 29.97 22.23 21.94 28.17 28.81 21.08

Height [cm] 150 150 150 150 150 150

Angle [°] 340 11 360 293 331 11

Detector
PK AV AV PK PK AV

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 20 of 36

Plot for Channel 78

REPORT No.SZ25020263W02

Fre. (MHz) 2484.07 2485.01 2488.71 2489.08 2494.77 2495.45

Reading [dBV]
5.6 17.8 5.5 17.5 5.6 18.1

Level [dBV/m]
38.67 50.82 38.47 50.51 38.56 51.06

Factor [dB/m] 33.030 33.030 33.020 33.020 33.010 33.010

Limit [dBV/m]
54.00 74.00 54.00 74.00 54.00 74.00

Margin [dB] 15.33 23.18 15.53 23.49 15.44 22.94

Height [cm] 150 150 150 150 150 150

Angle [°] 144 236 144 172 337 204

Detector
AV PK AV PK AV PK

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 21 of 36

8-DPSK Mode Plot for Channel 0

REPORT No.SZ25020263W02

Fre. (MHz) 2319.71 2352.44 2375.17 2375.27 2383.17 2385.88

Reading [dBV]
-0.2 -0.3 0.4 12.8 13.1 12.8

Level [dBV/m]
31.88 32.13 32.93 45.28 45.57 45.36

Factor [dB/m] 32.110 32.400 32.490 32.490 32.520 32.530

Limit [dBV/m]
54.00 54.00 54.00 74.00 74.00 74.00

Margin [dB] 22.12 21.87 21.07 28.72 28.43 28.64

Height [cm] 150 150 150 150 150 150

Angle [°] 243 105 48 310 0 77

Detector
AV AV AV PK PK PK

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 22 of 36

Plot for Channel 78

REPORT No.SZ25020263W02

Fre. (MHz) 2484.63 2484.85 2487.54 2490.11 2492.86 2493.46

Reading [dBV]
5.7 18.0 5.5 17.6 5.4 18.8

Level [dBV/m]
38.74 51.06 38.51 50.62 38.45 51.81

Factor [dB/m] 33.030 33.030 33.020 33.020 33.010 33.010

Limit [dBV/m]
54.00 74.00 54.00 74.00 54.00 74.00

Margin [dB] 15.26 22.94 15.49 23.38 15.55 22.19

Height [cm] 150 150 150 150 150 150

Angle [°] 177 0 108 279 350 258

Detector
AV PK AV PK AV PK

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 23 of 36

REPORT No.SZ25020263W02
A.3. Radiated Emission
According to ANSI C63.10, because of peak detection will yield amplitudes equal to or greater than amplitudes measured with the quasi-peak (or average) detector, the measurement data from a spectrum analyzer peak detector will represent the worst-case results, if the peak measured value complies with the quasi-peak (or average) limit, it is unnecessary to perform an quasi-peak measurement (or average).
The measurement results are obtained as below: E [dBV/m] =UR + AT + AFactor [dB]; AT =LCable loss [dB]-Gpreamp [dB] AT: Total correction Factor except Antenna UR: Receiver Reading Gpreamp: Preamplifier Gain AFactor: Antenna Factor at 3m During the test, the total correction Factor AT and AFactor were built in test software. Note1: All radiated emission tests were performed in X, Y, Z axis direction. And only the worst axis test condition was recorded in this test report. Note2: For the frequency, which started from 9kHz to 30MHz, was pre-scanned and the result which was 20dB lower than the limit was not recorded. Note3: For the frequency, which started from 18GHz to 10th harmonic of the highest frequency, was pre-scanned and the result which was 20dB lower than the limit was not recorded. Note 4: All test modes were considered and evaluated respectively by performing full test, only the worst data were recorded.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 24 of 36

GFSK Mode Plot for Channel 0

REPORT No.SZ25020263W02

Fre. (MHz) 55.90 104.74 163.92 250.01 531.52 750.02

(Antenna Horizontal, 30MHz to 1GHz)

Reading [dBV]
61.1 67.3 67.5 68.4 52.8 47.5

Level [dBV/m]
33.07 38.02 36.49 40.93 33.81 32.68

Factor [dB/m] -28.020 -29.300 -31.050 -27.490 -18.950 -14.840

Limit [dBV/m]
40.00 43.50 43.50 46.00 46.00 46.00

Margin [dB] 6.93 5.48 7.01 5.07 12.19 13.32

Height [cm] 150 150 150 150 150 150

Angle [°] 330 302 188 351 139 266

Detector
PK PK PK PK PK PK

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 25 of 36

REPORT No.SZ25020263W02

(Antenna Horizontal, 1GHz to 18GHz)

Fre. (MHz) 1596.52 1596.92 2469.89 2470.29 3202.72 3203.15 5113.35 5123.63 11102.37 11117.37 14616.76 14729.91

Reading [dBV]
43.4 33.4 28.3 40.4 54.0 50.4 47.4 37.2 30.4 39.3 27.2 36.0

Level [dBV/m]
43.00 32.99 34.17 46.29 43.09 39.50 44.27 34.20 44.45 53.24 47.61 56.32

Factor [dB/m] -0.420 -0.420 5.920 5.920 -10.880 -10.880 -3.130 -2.960 14.070 13.970 20.380 20.340

Limit [dBV/m]
74.00 54.00 54.00 74.00 74.00 54.00 74.00 54.00 54.00 74.00 54.00 74.00

Margin [dB] 31.00 21.01 19.83 27.71 30.91 14.50 29.73 19.80 9.55 20.76 6.39 17.68

Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150

Angle [°] 39 39 214 50 104 104 239 64 130 171 280 358

Detector
PK AV AV PK PK AV PK AV AV PK AV PK

Verdict
PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 26 of 36

REPORT No.SZ25020263W02

Fre. (MHz) 30.63 54.15 104.74 164.50 282.60 749.97

(Antenna Vertical, 30MHz to 1GHz)

Reading [dBV]
65.7 62.2 63.0 63.7 60.9 49.7

Level [dBV/m]
34.92 34.61 33.70 32.51 34.57 34.89

Factor [dB/m] -30.750 -27.590 -29.300 -31.220 -26.310 -14.840

Limit [dBV/m]
40.00 40.00 43.50 43.50 46.00 46.00

Margin [dB] 5.08 5.39 9.80 10.99 11.43 11.11

Height [cm] 150 150 150 150 150 150

Angle [°] 188 300 125 40 245 188

Detector
PK PK PK PK PK PK

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 27 of 36

REPORT No.SZ25020263W02

(Antenna Vertical, 1GHz to 18GHz)

Fre. (MHz) 1658.13 1663.33 2402.28 2475.50 3202.72 3203.15 7049.26 7173.98 11104.52 11480.39 14674.19 14683.19

Reading [dBV]
32.3 44.2 30.7 40.2 58.3 56.4 44.7 35.1 39.1 29.7 35.8 26.4

Level [dBV/m]
32.29 44.18 35.93 46.10 47.43 45.50 49.06 39.99 53.20 43.95 56.34 46.99

Factor [dB/m] -0.010 0.020 5.250 5.910 -10.880 -10.880 4.350 4.850 14.060 14.230 20.530 20.560

Limit [dBV/m]
54.00 74.00 54.00 74.00 74.00 54.00 74.00 54.00 74.00 54.00 74.00 54.00

Margin [dB] 21.71 29.82 18.07 27.90 26.57 8.50 24.94 14.01 20.80 10.05 17.66 7.01

Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150

Angle [°] 133 133 143 105 144 144 64 144 185 211 331 265

Detector
AV PK AV PK PK AV PK AV PK AV PK AV

Verdict
PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 28 of 36

Plot for Channel 39

REPORT No.SZ25020263W02

Fre. (MHz) 55.85 104.74 163.96 264.02 331.78 750.02

(Antenna Horizontal, 30MHz to 1GHz)

Reading [dBV]
61.7 67.8 66.6 62.9 58.8 46.2

Level [dBV/m]
33.68 38.53 35.54 35.32 34.42 31.40

Factor [dB/m] -28.010 -29.300 -31.040 -27.550 -24.390 -14.840

Limit [dBV/m]
40.00 43.50 43.50 46.00 46.00 46.00

Margin [dB] 6.32 4.97 7.96 10.68 11.58 14.60

Height [cm] 150 150 150 150 150 150

Angle [°] 358 313 171 9 178 236

Detector
PK PK PK PK PK PK

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 29 of 36

REPORT No.SZ25020263W02

(Antenna Horizontal, 1GHz to 18GHz)

Fre. (MHz) 1047.61 1066.41 2414.28 2441.49 3254.58 7173.12 7200.98 10700.79 11505.24 14542.19 14733.76

Reading [dBV]
35.0 48.3 39.9 32.5 52.5 44.1 34.3 31.0 39.0 36.5 27.2

Level [dBV/m]
32.21 45.69 45.33 38.37 41.15 48.94 39.39 43.42 53.24 56.49 47.50

Factor [dB/m] -2.760 -2.600 5.430 5.840 -11.300 4.840 5.110 12.450 14.280 20.030 20.310

Limit [dBV/m]
54.00 74.00 74.00
74.00 74.00 54.00 54.00 74.00 74.00 54.00

Margin [dB] 21.79 28.31 28.67 32.85 25.06 14.61 10.58 20.76 17.51 6.50

Height [cm] 150 150 150 150 150 150 150 150 150 150 150

Angle [°] 351 19 177 231 306 64 117 130 130 64 360

Detector
AV PK PK AV PK PK AV AV PK PK AV

Verdict
PASS PASS PASS
NA PASS PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 30 of 36

REPORT No.SZ25020263W02

Fre. (MHz) 30.58 51.63 98.44 199.95 282.60 750.02

(Antenna Vertical, 30MHz to 1GHz)

Reading [dBV]
66.9 63.1 63.6 62.4 60.8 48.4

Level [dBV/m]
36.10 35.13 33.91 33.63 34.49 33.51

Factor [dB/m] -30.750 -28.010 -29.690 -28.780 -26.310 -14.840

Limit [dBV/m]
40.00 40.00 43.50 43.50 46.00 46.00

Margin [dB] 3.90 4.87 9.59 9.87 11.51 12.49

Height [cm] 150 150 150 150 150 150

Angle [°] 130 345 186 45 258 115

Detector
PK PK PK PK PK PK

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 31 of 36

REPORT No.SZ25020263W02

(Antenna Vertical, 1GHz to 18GHz)

Fre. (MHz) 1648.13 1670.93 2440.69 2441.49 3254.58 3255.01 6396.10 6396.53 10614.65 10636.50 14448.33 14669.48

Reading [dBV]
44.2 31.6 41.2 39.0 57.2 55.6 48.4 38.8 41.5 31.3 27.4 35.5

Level [dBV/m]
44.08 31.62 47.01 44.85 45.85 44.33 49.39 39.83 53.65 43.49 46.60 55.97

Factor [dB/m] -0.080 0.060 5.830 5.840 -11.300 -11.300 1.010 1.010 12.140 12.230 19.220 20.520

Limit [dBV/m]
74.00 54.00
74.00 54.00 74.00 54.00 74.00 54.00 54.00 74.00

Margin [dB] 29.92 22.38 28.15 9.67 24.61 14.17 20.35 10.51 7.40 18.03

Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150

Angle [°] 150 128 155 155 146 146 9 9 267 348 37 187

Detector
PK AV PK AV PK AV PK AV PK AV AV PK

Verdict
PASS PASS
NA NA PASS PASS PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 32 of 36

Plot for Channel 78

REPORT No.SZ25020263W02

Fre. (MHz) 55.90 104.74 163.96 264.56 530.93 750.02

(Antenna Horizontal, 30MHz to 1GHz)

Reading [dBV]
62.3 67.6 67.7 62.3 48.8 44.0

Level [dBV/m]
34.23 38.29 36.64 34.85 29.85 29.13

Factor [dB/m] -28.020 -29.300 -31.040 -27.480 -18.930 -14.840

Limit [dBV/m]
40.00 43.50 43.50 46.00 46.00 46.00

Margin [dB] 5.77 5.21 6.86 11.15 16.15 16.87

Height [cm] 150 150 150 150 150 150

Angle [°] 344 324 190 1 324 217

Detector
PK PK PK PK PK PK

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 33 of 36

REPORT No.SZ25020263W02

(Antenna Horizontal, 1GHz to 18GHz)

Fre. (MHz) 1069.21 1069.61 3306.44 3306.87 5214.06 5214.92 6777.54 6782.25 11099.37 11147.80 14521.61 14687.48

Reading [dBV]
47.1 34.7 50.1 45.7 47.7 40.6 45.9 35.6 39.8 30.3 27.3 36.0

Level [dBV/m]
44.55 32.11 39.13 34.71 44.29 37.23 49.77 39.42 53.85 44.12 47.24 56.52

Factor [dB/m] -2.580 -2.580 -11.000 -11.000 -3.420 -3.410 3.900 3.870 14.070 13.790 19.920 20.570

Limit [dBV/m]
74.00 54.00 74.00 54.00 74.00 54.00 74.00 54.00 74.00 54.00 54.00 74.00

Margin [dB] 29.45 21.89 34.87 19.29 29.71 16.77 24.23 14.58 20.15 9.88 6.76 17.48

Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150

Angle [°] 18 24 332 332 9 9 360 251 104 319 9 332

Detector
PK AV PK AV PK AV PK AV PK AV AV PK

Verdict
PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 34 of 36

REPORT No.SZ25020263W02

Fre. (MHz) 30.63 62.45 81.22 184.33 282.60 750.02

(Antenna Vertical, 30MHz to 1GHz)

Reading [dBV]
65.2 64.4 65.7 63.5 60.8 44.0

Level [dBV/m]
34.48 35.66 33.59 33.39 34.44 29.13

Factor [dB/m] -30.750 -28.750 -32.060 -30.090 -26.310 -14.840

Limit [dBV/m]
40.00 40.00 40.00 43.50 46.00 46.00

Margin [dB] 5.52 4.34 6.41 10.11 11.56 16.87

Height [cm] 150 150 150 150 150 150

Angle [°] 147 110 54 230 265 68

Detector
PK PK PK PK PK PK

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 35 of 36

REPORT No.SZ25020263W02

(Antenna Vertical, 1GHz to 18GHz)

Fre. (MHz) 1111.62 1123.22 2470.29 2480.30 3306.87 3306.87 7203.98 7209.12 11091.23 11105.37 14693.91 14703.76

Reading [dBV]
32.8 44.1 39.5 31.8 47.9 51.8 44.2 34.5 39.7 30.2 35.6 27.2

Level [dBV/m]
30.58 41.97 45.44 37.69 36.90 40.82 49.26 39.51 53.66 44.28 56.13 47.73

Factor [dB/m] -2.260 -2.160 5.920 5.890 -11.000 -11.000 5.060 4.980 13.970 14.040 20.580 20.570

Limit [dBV/m]
54.00 74.00 74.00
54.00 74.00 74.00 54.00 74.00 54.00 74.00 54.00

Margin [dB] 23.42 32.03 28.56 17.10 33.18 24.74 14.49 20.34 9.72 17.87 6.27

Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150

Angle [°] 138 133 231 149 63 171 347 63 292 212 89 332

Detector
AV PK PK AV AV PK PK AV PK AV PK AV

Verdict
PASS PASS PASS
NA PASS PASS PASS PASS PASS PASS PASS PASS

END OF REPORT

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 36 of 36


Acrobat Distiller 9.3.2 (Windows)