Temperzone ISD 211LYX and OSA 211RLTFH Air Conditioner Specifications and Wiring

Specifications

FeatureIndoor Unit (ISD 211LYX)Outdoor Unit (OSA 211RLTFH)
Cooling capacity range (gross)9.4 ~ 25.3 kW
Cooling capacity (net) to AS/NZS 3823 T119.0 kW
Heating capacity range8.4 ~ 25.6 kW
Heating capacity H120.8 kW
Electrical input - cooling6.0 kW
Electrical input - heating5.8 kW
EER / AEER (cooling)3.15 / 3.13
COP / ACOP (heating)3.57 / 3.54
Unit ControllersUC8 / IUC
RefrigerantR32
Refrigerant precharge for 15 m5.2 kg
Minimum floor area (@2.4m below ceiling diffuser)14.4 m²
Additional charge req'd for over 15 m60 g/m
Maximum line length60 m
Max. charge / Min. floor area (below ceiling diffuser)7.9 kg / 33.2 m²
Separation limit: OSA above ISD20 m
Separation limit: OSA below ISD20 m
Suction line19 mm OD
Liquid line9.5 mm OD
Compressor oil typePOE-46 (NXG5020 or equivalent)
Additional oil charge over 40 m length10 ml/m
Compressor typeinverter scroll
Power supply via OSA3 ph. 400V ac 50Hz
Compressor (3ph.) run amps at rating cond.9.0 A
Indoor fan motor size1250 W
Rated indoor fan speed6.5 V
Indoor fan motor (1ph.) - full load6 A
Outdoor fan motor (1ph.) - full load1 A (x2)
Outdoor fan capacitor size5 μfd (x2)
Control circuit breaker (internal)10 A
Running amps (total system)13.0 / 9.0 / 10.0 A
Max. running amps (total system)23.0 / 14.5 / 15.5 A
RCD type recommendedtype B, 30mA
Net weight ISD / OSA86 / 129 kg

Accessories

Optional Controls

Refer to Temperzone for other options, e.g., remote sensors, connection wires.

Tested in accordance with AS/NZS 3823.

Dimensions and Load Points

ISD 211LYX Indoor Unit Dimensions:

The diagram illustrates the unit's overall dimensions, including width (W), depth (X), height (Y), and mounting center dimensions (Z). It indicates clearance requirements (e.g., 500mm minimum clearance) and the location of access panels and optional filter boxes.

Indoor Unit Point Loads (kg):

PointWXYZ
Load21242120

Note: The fan motor can be accessed from panels above, below, or on the sides, with a maximum of two panels used at once.

OSA 211RLTF Outdoor Unit Dimensions:

This diagram shows the outdoor unit's overall dimensions, including width (W), depth (X), height (Y), and mounting center dimensions (Z). It highlights clearance requirements (e.g., 150mm, 750mm minimum clearances), refrigerant connections, electrical box location, drain holes (25mm diameter), and optional filter box access.

Outdoor Unit Point Loads (kg):

PointWXYZ
Load21403731

Recommended Connecting Pipe Sizes:

Note: Specifications are subject to change without notice due to the manufacturer's ongoing research and development program.

Indoor Unit Wiring

This section details the internal wiring of the indoor unit and its connection to the outdoor unit. Key elements include:

Note: Refer to the 'Installation & Maintenance' pamphlet for detailed indoor-outdoor connection wiring.

Outdoor Unit Wiring

This section outlines the external wiring and internal connections of the outdoor unit. Key components and connections include:

Note: Refer to the 'Installation & Maintenance' pamphlet for detailed indoor-outdoor connection wiring and alternative thermostat or BMS options.

PDF preview unavailable. Download the PDF instead.

ISD 211LYX Specifications 0221 Adobe PDF Library 15.0 Adobe InDesign 16.1 (Macintosh)

Related Documents

PreviewTemperzone ISD 324KYX OSA 324RKTFV Air Conditioner Specifications and Dimensions
Comprehensive technical specifications, dimensional data, and wiring schematics for the Temperzone ISD 324KYX Indoor Unit and OSA 324RKTFV Outdoor Unit air conditioning system. Features include cooling/heating capacity, electrical inputs, refrigerant details, and installation guidance.
PreviewtemperZONE OPA 171RLTFY(H/V) Econex Air Conditioner Specifications and Wiring
Technical specifications, dimensional data, and electrical wiring schematics for the temperZONE OPA 171RLTFY(H/V) Econex air conditioning unit, featuring R32 refrigerant and UC8 controller.
Previewtemperzone OPA 171RLTFYD Econex Pro HVAC Unit Specifications and Wiring
Detailed specifications, dimensions, and electrical wiring diagrams for the temperzone OPA 171RLTFYD Econex Pro HVAC unit, featuring R32 refrigerant and inverter scroll compressor.
Previewtemperzone CWP Ducted Water Cooled Packaged Air Conditioners Installation & Maintenance Manual
Comprehensive installation and maintenance guide for temperzone CWP series ducted water-cooled packaged air conditioners, featuring the UC8 controller. Includes setup, wiring, troubleshooting, and safety information for optimal performance and reliability.
PreviewTemperzone Econex Ducted Split Units: High Efficiency Air Conditioning
Explore Temperzone's Econex range of air-cooled ducted split air conditioning units, featuring R32 refrigerant for lower GWP, advanced inverter technology, and high performance for commercial and industrial applications. Discover features, specifications, and control options.
PreviewTemperzone HWP Ducted Water Cooled Packaged Air Conditioners Installation and Maintenance Manual
This manual provides detailed installation and maintenance instructions for Temperzone HWP Ducted Water Cooled Packaged Air Conditioners (c/w UC8). It covers general information, installation procedures, water connections, wiring, unit protection, start-up, controls, troubleshooting, and warranty details.
PreviewTemperzone OPA 211RLTFY(H/V) Econex Air Conditioner Specifications and Wiring
Detailed specifications, dimensional data, and electrical wiring schematics for the Temperzone OPA 211RLTFY(H/V) Econex air conditioning unit, including component definitions and DIP switch settings.
PreviewTemperzone Ducted Packaged Units OPA 1410/1710/2110 Econex Series R32 Technical Data
Comprehensive technical data, specifications, performance charts, and features for Temperzone's OPA 1410, 1710, and 2110 Econex Series R32 ducted packaged rooftop air conditioning units, designed for commercial environments.