
Montigo Distinction Fireplaces by Montigo- Ontario Hearth Fireplaces Ltd. - Oakville, Mississauga, Burlington
MUST READ BEFORE FRAMING IMPORTANT INFORMATION Montigo Distinction D3615/D3615ST D4815/D4815ST D7215/D7215ST FRAMING DIMENSIONS SPECIFICATIONS HEAT RELEASE REQUIREMENTS QR LINK FOR PDF DIGITAL COPY OF SPECIFICATIONS: General Section 1: Product Dimensions SINGLE SIDED A B B C D SEE THROUGH A C D E F G C J F L K I H Figure 2. Distinction Fireplace dimensions (Tolerance ± "). D3615 SINGLE SIDED DIMENSIONS A B C D E F G H I J K L 517/8 167/8 403/4 593/4 377/8 17 151/2 61/8 23/8 135/8 103/8 41 D4815 SINGLE SIDED DIMENSIONS A B C D E F G H I J K L 637/8 167/8 5213/16 713/4 497/8 17 15 61/8 23/8 135/8 103/8 41 D7215 SINGLE SIDED DIMENSIONS A B C D E F G H I J K L 877/8 177/8 763/4 9511/16 737/8 17 151/2 51/2 23/8 135/8 103/8 41 XG0222 E F G C J F L K I H Figure 2.b Distinction Fireplace dimensions (Tolerance ± "). D3615 SEE THROUGH DIMENSIONS A B C D E F G H I J K L 517/8 173/4 403/4 593/4 377/8 17 151/2 813/16 23/8 135/8 103/8 41 D4815 SEE THROUGH DIMENSIONS A B C D E F G H I J K L 637/8 1711/16 5213/16 713/4 497/8 17 15 51/2 23/8 139/16 103/8 41 D7215 SEE THROUGH DIMENSIONS A B C D E F G H I J K L 877/8 173/4 763/4 9511/16 737/8 17 151/2 51/2 23/8 135/8 103/8 41 7 Installation Section 2: Framing Thursday, August 19, 2021 8:41:55 AM MODEL Top to combustible header Sides Floor Back Base of unit to ceiling PROPRIETARY AND CONFIDENTIAL Clearances To ensure the fireplace operates safely, all models must maintain the following clearances: D3615 813/16'' 4'' D3615ST 813/16'' 4'' D4815 813/16'' 4'' D4815ST 813/16'' 4'' D7215 185/16'' 4'' D7215ST 185/16'' 4'' Figure 3. Combustible Clearances 0'' .5'' 89'' 0'' N/A 89'' 0'' .5'' 89'' 0'' N/A 89'' 0'' .5'' 89'' 0'' N/A 89'' Note: If measuring from bottom edge of cement board to ceiling, minimum clearance is 92¼. Unprotected combustible walls which are perpendicular to the fireplace opening must maintain 6" clearance. NOTE: When constructing the framed opening, please ensure there is access to install the gas line when the unit is installed. WARNING When this appliance is installed directly on ANY combustible other than wood flooring (carpet, vinyl, etc.). It must be installed on an equivalent wood or metal panel. This material must extend the full width and depth of the appliance. PROPRIETARY AND CONFIDENTIAL Non Combustible Framing Non-combustible framing is required for all Distinction models. Y:\Products\Residential Products\R&D Projects\DL72ST\Cad Drawings\DL72ST-No Combustible Framing Assembly 388.163 15 A5 16 " 41684B.15366"3 1215.161 47C1136 " 2432 9D5 34 " 1215.161 47 C13 16 " ITEM NO. PART NUMBER DESCRIPTION 1 DL72097-20 Non-Combustible stud, Horizontal 2 DL72098-20 DL72-Non-Combustible stud, Vertical 3 DL72099-20 DL72-Non-Combustible Stud Connector NON COMBUSTIBLE FRAMING DIMENSIONS 1 3 2 A B C D D3615 DIMENSIONS ARE IN INCHES 513/16 TOLERANCES: FRACTIONAL 1/32" 813/16 Drawn by NAME DATE Description 297/8 5911/16 DM 02/27/2018 DL72ST-Non Combustible Framing TWO PLACE DECIMAL .015" THREE PLACE DECIMAL .005" Revision / Date DWG. NO. DL72ST-No Combustible Framing Assembly D4815 ANGULAR .5 513/16 ALL BENDS ARE ASSUMED TO BE 90 UNLESS NOTED OTHERWISE. Revision 813/16 Finish 357/8 MATERIAL 7111/16 SCALE 1:24 WEIGHT: SHEET 1 OF 2 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEATING PRODUCTS IS PROHIBITED. D7215 1513/16 185/16 4713/16 953/4 Recommended flooring considerations Flooring such as Luxury Vinyl Plank (LVP) and other vinyl flooring can REVISIONS DIMENSIONS ARE IN INCHES TOLERANCES: FRACTIONAL 1/32" Drawn by NAME DATE Description DM 02/27/2018 DL72ST-Non Combus be sensitive to radiant heat and changes in temperature. If using vinyl REV. DESCRIPTION DATE CHANGED BY TWO PLACE DECIMAL .015" THREE PLACE DECIMAL .005" Revision / Date DWG. NO. DL72ST-No Combustible Fr ANGULAR .5 Revision MATERIAL flooring we recommend you install the fireplace in one of the ways - . - - ALL BENDS ARE ASSUMED TO BE 90 UNLESS NOTED OTHERWISE. Finish SCALE 1:24 WEIGHT: shown below. THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEATING PRODUCT Floor mounted fireplace Raised fireplace NOTICE Clearances must be in accordance with local installation codes and the requirements of the gas supplier NOTICE Framing measurement includes 2¼" platform to avoid driving screws into important components inside the fireplace box. 24" Min. hearth Vinyl Flooring Hearth The minimum width of the hearth is equal to the width of the fireplace. 16" Min. rise Flush Vinyl Flooring Raise the fireplace 16" above the floor to allow for vinyl flooring to be installed flush to the wall. (Measured from floor to the bottom of the door opening) 8 XG0222 Installation Framing the Single Sided Fireplace Framing the See-Through Fireplace A B 1 D 2 C E 3 Minimum chase height 89" A B 1 2 D C E 3 Minimum chase height 89" A B 4915/16 21/4 A B 4915/16 21/4 A B 593/8 21/4 D3615 SINGLE SIDED DIMENSIONS C D E F G H I 411/16 593/4 171/2 107/8 407/8 24 171/8 J K 129/16 5311/16 D4815 SINGLE SIDED DIMENSIONS C D E F G H I 411/16 713/4 171/2 107/8 527/8 24 171/8 J K 129/16 5311/16 D7215 SINGLE SIDED DIMENSIONS C D E F G H I J K 411/16 953/4 181/2 107/8 767/8 337/16 171/8 129/16 631/8 1 Floor structure 2 Non-combustible metal framing 3 Fireplace platform 4 Cement board A B 4915/16 21/4 A B 4915/16 21/4 A B 593/8 21/4 D3615 SEE THROUGH DIMENSIONS C D E F G H I 411/16 593/4 1711/16 107/8 407/8 24 171/8 J K 129/16 5311/16 D4815 SEE THROUGH DIMENSIONS C D E F G H I 411/16 713/4 1711/16 107/8 527/8 24 171/8 J K 129/16 5311/16 D7215 SEE THROUGH DIMENSIONS C D E F G H I J K 411/16 953/4 1711/16 107/8 767/8 337/16 171/8 129/16 631/8 IMPORTANT Cement board: The included cement board is sized to overlap the 2x4 and platform noted in the framing section. The board will not fit if the unit is placed directly on the floor. NOTICE When using dimensional lumber to build fireplace framing, wood studs must be completely dry, sound and straight. Ignoring recommendation will cause stress point formations and potential cracks in finishing materials XG0222 9 Installation Cement board recomendations F 206 8 1 8 " 6166G8180" 625 24H58 " 1641I129 " 31J330" 82018F6" 1375 54K18 " D3615 CEMENT BOARD DIMENSIONS F G H I J K 107/8 407/8 24 171/8 129/16 5311/16 D4815 CEMENT BOARD DIMENSIONS F G H I J K 107/8 527/8 24 171/8 129/16 5311/16 D7215 CEMENT BOARD DIMENSIONS F G H I J K 107/8 767/8 337/16 171/8 129/16 631/8 NOTICE Supplied cement board can be drilled to add extra fasteners or support if finishing application calls for it. No extra fasteners shall be used to attach cement board to fireplace body NOTICE It is highly recommended to apply high temp resistant RTV Silicone where cement board touches fireplace body. At least 48h cure time before applying finishing or firing fireplace IMPORTANT Cement board: The outside edge of the cement board facing must be in the center of a structural stud. IMPORTANT Cement board: The included cement board facing is sized to overlap the 2x4 and platform noted in the framing section. The board will not fit if the unit is placed directly on the floor. 10 NOTICE Supplied cement board is for minimum installation requirements for noncombustible surfaces. When installing heavy finishing materials such as Natural Stone, Granite, Marble, Etc., Full sheets (4'x8') of cement board is recommended to minimize number of joints and to reduce risk of cracking (supplied cement board can be used as stencil to predrill new cement sheets) Any replacement sheet of cement board must be calcium silicate based as to withstand continuous high operating temperatures. XG0222 Clearance to Sprinkler · Maintain 48" of clearance to openings from which heat is discharged such as chase venting and Cool Wall Advantage. · Please follow local building codes to determine what sprinkler head sensor setting is relevant for your installation. Installation 48" Chase venting At a minimum, a 120 square inch opening is required in the finished enclosure to keep temperatures within a safe level. This can be achieved in a variety of ways such as the few shown below. TV recess framing 3" Min. from ceiling The recess MUST be made from Non-Combustable materials. Maintain 1" clearance from venting to combustibles. 4" Max Depth 12" min. from fireplace opening TV RECESS Figure 19.b Side chase venting (6"x10") on both sides of enclosure Figure 19.c Top chase venting (3"x40") on top of enclosure Minimum 2" gap Figure 8.b.d Cool Wall Advantage TV recess dimensions The recess must be made from Non-Combustable materials. Recess can be increased beyond a 4" depth by using a 45° or 90° elbow in venting after the minimum 3' upward distance is achieved, 1" clearance from venting to combustibles must still be maintained. Ceiling Corner framing Figure 19.d Front chase venting (2"x60") on front of enclosure Figure 19.d Open top chase venting on top of enclosure The opening of the chase cannot be lower than 3" from the top of the enclosure to prevent heat from pocketing at the top of the enclosure. A minimum of 2" from the top of a chase vent to the ceiling is needed. Any combination of the above examples is an acceptable chase vent providing they add up to at least 120 square inches. NOTE: Chase venting not required if using Cool Wall Advantage heat diversion system. XG0222 A B D36 D48 D72 Dimensions A B 26 3/16 64 30 7/16 73 39 91¾ 11 WARNING The use of the fans when the Cool Wall Release OR Cool Wall Advantage system is used will result in significantly higher wall temperatures. These higher temperatures can negatively impact the finished wall surface, art, and or mounted TV. Therefore, Montigo STRONGLY RECOMMENDS that fans be disconnected when the Cool Wall Release OR Cool Wall Advantage system is used. This can be done through the remote control (See instructions) or by disconnecting the fan harness. Montigo is NOT responsible for damage to facing materials, and items placed above the fireplace (eg. TV, artwork) Disable fans via remote 1. Turn the fireplace on, turn fans to off setting. 2. Partially take out one battery. 3. Hold both the Mode AND On/Off button. 4. Insert battery (while still holding the two buttons), then release Mode button (keep On/Off pressed). 5. Cycle through modes with Mode button until you get to fan setting, with Down button set fan function from Set to Clr. 6. Release On/Off button, turn the fireplace on. There will be now be no fan mode on remote. Installation 12 XG0222 Installation Framing with Cool Wall Advantage NOTICE The temperature above the fireplace will rise with the use of fans when also using the Cool Wall Kit. If fan use is expected then a mantel is needed. · Refer to the chart below to detemine the length of 5'' diameter flex pipe required for completion of installation (12' or 24'). Flex pipe is available from Montigo as part # HDKPDFK and HDKPDFK-1. · The installation of this fireplace must be done by a qualified and certified gas appliance installer. · Check local codes and read all instructions prior to installation. · Minimum clearance to flexible ducting is 1" UNIT COMPATIBILITY Cool Wall Advantage Kit HDKPD** [Includes louver , plenum, requires flex kit] Cool wall system D3615NI-2 D4815NI-2 D6315NI-2 D7215NI-2 HDKPD36 HDKPD48 HDKPD63 HDKPD72 HDKSD HDKSVD HDKPDFK-1 HDKPDFK Cool Wall Flex Kit HDKPDFK HDKPDFK-1 [HDKPDFK-1 is 12' of 5'' Diameter flex pipe, HDKPDFK is 24' of 5'' Diameter flex pipe] COOL WALL TV KIT DIMENSIONS A B C D E F G H I 36" 3913/16" 387/8" 3" 1½" N/A 2" 95/16" N/A 71/16" C736" 48" 517/8" 507/8" 3" 1½" 30½" 2" 95/16" 21" 71/16" 63" 661/16" 651/16" 3" 1½" 383/16" 2" 95/16" 21" 65/16" 72" 7513/16" 7413/16" 3" 1½" 397/16" 2" 95/16" 21" 71/16" 1D3128" 533 21" Cool Wall Advantage Side Discharge Kit horizontal HDKSD [Includes 2 louvers , 2 plenums, requires flex kit] Cool Wall Advantage Side Discharge Kit vertical HDKSVD [Includes 2 louvers , 2 plenums, requires flex kit] 167 66 1 1 1653 76 An alternate 5-inch diameter duct may be use3d" with this kit 65 1 16 " OPENING providing it is metal and meet requirements of UL-181 Class 1 Air Duct. Flexible aluminium duct is acceptable provided it meets the UL-181 Class 1 requirements. 1653 65 B116 " OPENING 1678 66A116 " 236 9 5 16 " 970 38 E3 16 " 38 1 1 2 " August-23-18 2:12:43 PM 51 F 2" OPENING 236 9 5G 16 " 970 38 3 16 " 5H33 21" 53 22111/616"" 180 7 I1 16 " DIMENSION TOLERANC FRACTION TWO PLAC THREE PLA ALL BENDS TO BE 90 OTHERWIS THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS. ANY REPRODUCTION IN P PROPRIETARY AND CONFIDENTIAL Y:\Products\Residential Products\R&D Projects\DL63\Cad Drawings\DL63-Heat distribution TV kit PROPRIETARY AND CONFIDENTIAL 180 7 1 16 " DIMENSIONS ARE IN INCHES TOLERANCES: FRACTIONAL 1/32" TWO PLACE DECIMAL .015" THREE PLACE DECIMAL .005" ALL BENDS ARE ASSUMED TO BE 90 UNLESS NOTED OTHERWISE. Drawn by NAME DM Revision / Date B Revision Finish DATE 31/03/2017 Description DL63 Heat Distribution TV Kit DWG. NO. DL63-Heat distribution TV kit MATERIAL SCALE 1:24 WEIGHT: SHEET 3 OF 3 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEATING PRODUCTS IS PROHIBITED. XG0222 13