Global Industrial™ Portable Air Conditioner with Heat
Model: 293136
Key Features: 12000 BTU Cooling/Heating, Wifi Enabled, Digital Display, Remote Control, Timer, Multiple Fan Speeds, Dehumidifier Mode.
Introduction
This manual provides essential information for the safe installation, operation, and maintenance of your Global Industrial™ Portable Air Conditioner with Heat, Model 293136. Please read this manual thoroughly before using the unit.
Safety Precautions
- Read all instructions before use.
- Ensure the unit is connected to a properly grounded electrical outlet.
- Do not operate the unit with a damaged cord or plug.
- Keep the power cord away from heated surfaces.
- Do not immerse the unit, cord, or plug in water or other liquids.
- Allow at least 1 foot (30 cm) of clearance around the unit for proper ventilation.
- Do not block air intake or exhaust vents.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, unless supervised.
- Children should be supervised to ensure they do not play with the appliance.
- Always unplug the unit before cleaning or performing maintenance.
- Dispose of water collected in the unit according to local regulations.
Installation
Proper installation is crucial for efficient operation. The following describes typical installation steps:
1. Unit Placement
Place the unit on a flat, stable surface, away from direct sunlight and heat sources. Ensure adequate clearance (at least 12 inches / 30 cm) around the unit for airflow.
2. Exhaust Hose Setup
Connect the exhaust hose to the rear of the unit. Extend the hose to a suitable window or vent. The unit requires continuous ventilation to expel hot air.
Diagram Description: The rear of the unit shows an exhaust port where the flexible hose attaches. The hose is designed to direct hot air outside.
3. Window Kit Installation
Assemble the adjustable window slider panel and insert it into the window opening. Attach the exhaust hose connector to the panel. Ensure the window is sealed to prevent air leakage.
Diagram Description: A window slider panel is shown fitted into a standard window frame. The exhaust hose is connected to an opening in this panel, directing air outwards. The panel is designed to seal the remaining window space.
4. Power Connection
Plug the unit into a grounded 115V electrical outlet.
Operation
The unit can be operated using the control panel on the unit or the included remote control.
Control Panel Functions
- Power Button (▶️): Turns the unit on or off.
- Mode Button: Selects operating mode: Cool, Heat, Fan, Dehumidify.
- Fan Speed Button: Adjusts fan speed: Low, Medium, High.
- Timer Button: Sets a timer for automatic shut-off or start-up.
- Temperature Up/Down Buttons: Adjusts the desired temperature setting.
Diagram Description: The front panel features a digital display showing the current temperature and mode. Clearly labeled buttons allow for mode selection, fan speed adjustment, timer setting, and temperature control.
Remote Control Functions
The remote control mirrors the functions of the control panel, allowing for convenient operation from a distance.
Maintenance and Cleaning
- Air Filter: Clean the air filter regularly (e.g., every two weeks) to maintain efficiency. Slide out the filter, wash it with mild soap and water, rinse, and dry completely before reinserting.
- Exterior: Wipe the exterior surfaces with a soft, damp cloth. Do not use abrasive cleaners.
- Water Drainage: The unit may collect condensation. Periodically check the water tank or drainage port. If the tank is full, unplug the unit and drain the water safely. Some models may have a continuous drain option.
Diagram Description: A diagram shows how to access and remove the air filter from the side or back of the unit for cleaning.
Troubleshooting
Problem | Possible Cause | Solution |
---|---|---|
Unit does not start | Power cord not plugged in. | Ensure the power cord is securely plugged into a working outlet. |
Circuit breaker tripped. | Check the household circuit breaker. | |
Not cooling/heating effectively | Air filter is dirty. | Clean or replace the air filter. |
Room temperature is too extreme. | Ensure the room temperature is within the unit's operating range. | |
Exhaust hose is blocked or not properly connected. | Check the exhaust hose for kinks or obstructions and ensure it's securely attached. | |
Water leaking from unit | Water tank is full. | Drain the water tank. |
Unit is not level. | Ensure the unit is placed on a level surface. |
Specifications
Specification | Value |
---|---|
Cooling Capacity | 12000 BTU/hr |
Heating Capacity | 12000 BTU/hr |
Power Supply | 115V / 60Hz |
Rated Current (Cooling) | Approx. 10.5 A |
Rated Current (Heating) | Approx. 12.0 A |
Power Consumption (Cooling) | Approx. 1200 W |
Power Consumption (Heating) | Approx. 1350 W |
Dehumidification Capacity | Approx. 70 pints/day |
Airflow (High) | Approx. 350 CFM |
Noise Level (Low/High) | Approx. 52 dB / 56 dB |
Unit Dimensions (W x D x H) | Approx. 18" x 15" x 30" |
Unit Weight | Approx. 70 lbs |
Refrigerant | R410A |
Note: Specifications are subject to change without notice.
Additional Information
For Wi-Fi setup and advanced features, please refer to the dedicated Wi-Fi setup guide or the manufacturer's website.
Diagram Description: A generic icon representing Wi-Fi connectivity (e.g., radiating waves) is shown next to the Wi-Fi enabled feature.
Related Documents
![]() | Global Industrial 293082 Window Air Conditioner User Manual and Installation Guide Comprehensive user manual and installation guide for the Global Industrial 293082 Window Air Conditioner. Covers safety instructions, installation steps, features, troubleshooting, and maintenance. |
![]() | GLOBAL INDUSTRIAL Through The Wall Air Conditioner with Wifi User Manual Comprehensive user manual for the GLOBAL INDUSTRIAL Through The Wall Air Conditioner with Wifi. Covers installation, operation, maintenance, and troubleshooting for models 292855, 293070, 292856, 292857, 292858, 292859, 292860, and 292861. |
![]() | Global Industrial High Capacity Portable Air Conditioner 293118 Owner's Manual Owner's manual for the Global Industrial High Capacity Portable Air Conditioner, Model 293118. This document provides instructions on assembly, operation, maintenance, and troubleshooting for the 60,000 BTU, 220V unit. |
![]() | Global Industrial Window Air Conditioner Model 293067 User Manual User manual for the Global Industrial Model 293067 Window Air Conditioner. Includes installation, operation, care, and troubleshooting instructions for this 5,000 BTU, Cool Only, 115V unit. |
![]() | Global Industrial Portable AC Instruction Manual Comprehensive instruction manual for Global Industrial Portable AC units (Models 292660, 292661, 292662, 292663), covering safety, installation, operation, maintenance, and troubleshooting. |
![]() | Global Industrial Portable Air Conditioners User Manual Comprehensive user manual for Global Industrial portable air conditioners, covering models 292660R, 292661R, and 292662R. Includes installation, operation, maintenance, safety guidelines, and troubleshooting. |
![]() | Global Industrial 293052 Commercial Air Scrubber 1000cfm Instruction Manual This instruction manual provides detailed information on the Global Industrial 293052 Commercial Air Scrubber, including safety guidelines, operating procedures, controls, filter maintenance, parts list, specifications, and troubleshooting tips for optimal performance and safety. |
![]() | Global Industrial 133716 18" Industrial Grade Air Needle Scaler User Manual Comprehensive user manual for the Global Industrial 133716 18" Industrial Grade Air Needle Scaler, covering safety, specifications, operation, maintenance, parts list, and warranty information. |