Installation Guide for Tigo models including: TS4-A-S, Module Add-On RSD Unit, TS4-A-S Module Add-On RSD Unit, RSD Unit

Quick Start Guide - TS4-A-S (700) working

PDF preview unavailable. Download the PDF instead.

611e6cf26c90ecf75f2a8517 Quick Start Guide - TS4-A-S (700W) (Add-on Safety)
1

TS4-A-S Installation Quick Start Guide

TS4-A-S
4 - 123A

Tigo Rapid Shutdown NEC 690.12-2017 and C22.1-2015 Rule 64.218
DO NOT DISCONNECT UNDER LOAD

2

TS4-A-S
4 - 123A

Tigo Rapid Shutdown NEC 690.12-2017 and C22.1-2015 Rule 64.218
DO NOT DISCONNECT UNDER LOAD

3

TS4-A-S
4 - 123A

Tigo Rapid Shutdown NEC 690.12-2017 and C22.1-2015 Rule 64.218
DO NOT DISCONNECT UNDER LOAD

TS4-A-S
4 - 123A

Tigo Rapid Shutdown NEC 690.12-2017 and C22.1-2015 Rule 64.218
DO NOT DISCONNECT UNDER LOAD

Note: When installing TS4-A or TS4-A-Duo, connect the input cables to the PV module before connecting the TS4-A output cables in series. If disconnecting TS4-A or TS4-A-Duo, disconnect the TS4-A output cables from the string before disconnecting the input cables from the PV module.

Removable clips Mounting holes (M8)

 support.tigoenergy.com

Tigo Rapid Shutdown NEC 690.12-2017 and C22.1-2015 Rule 64.218

DO NOT DISCONNECT

DANGER

UNDER LOAD

For installation with frameless modules, remove metal clips and bolt TS4-A to rail.




Manuals
support@tigoenergy.com
International: 00800.2255.8446 Americas: +1.408.402.0802

TS4-A-S: Safety

The TS4-A-S is the advanced add-on solution that brings smart module functionality to standard PV modules, including rapid shutdown and module-level monitoring.

Maximum power: 700W Maximum voltage: 90VDC Maximum current: 15ADC

*Collect TS4 bar code for system mapping to enable monitoring and safety features

Maximum string voltage 1000V/1500V depending on connectors.

TS4-A-S

4-1234T

Tigo Rapid Shutdown NEC 690.12-2017 and C22.1-2015 Rule 64.218

DO NOT DISCONNECT

DANGER

UNDER LOAD

Use ANSI/NFPA 70 wiring methods. Modules must not be installed in readily accessible locations. (Canada only) Connectors from different manufacturers cannot be mated with each other. Photovoltaic Rapid Shutdown Equipment NEC 690.12 and C22.1-2015 Rule 64-218
The Tigo Access Point (TAP) is a PVRSE device that provides a keep-alive signal to the TS4 (attenuator) device via wireless communications.
The Tigo Access Point (TAP) shall be powered from the same power as the RSI (Rapid Shutdown Initiator) circuit and tied to the shutdown of the inverter.

Class II double insulation
High Voltage
DANGER

E469960

Photovoltaic Rapid Shutdown System Equipment, QW

12

34

1 PV Module 2 String 3 String + 4 PV Module +
*Collect TS4 bar code for system mapping to enable monitoring and safety features

IMPORTANT NOTICE Electricity will be supplied to the Tigo TS4-A output cables immediately when connected to a PV module exposed to sunlight. Use care when handling.  Tigo TS4-A

ATTENTION! Une fois connecté au panneau photovoltaïque exposé au soleil, les boitiers Tigo TS4-A laisseront passer le courant. Soyez vigilant. WICHTIGER HINWEIS Bei Verbindung der Tigo TS4-A mit einem aktiven PV-modul steht der Ausgang unmittelbar unter Spannung. Bitte Vorsicht im Umgang. AVVISO IMPORTANTE Prestare la massima attenzione: i cavi di uscita dei Tigo TS4-A sono già alimentati con energia elettrica quando vengono collegati a un modulo fotovoltaico esposto alla luce del sole.          Tigo TS4-A      .  .  TS4-A  

¡PRECAUCION! Al momento de conectar los cabels de salida los Tigo TS4-A a un módulo fotovoltaico expuesto al sol, se iniciarà la corriente eléctrica. Tenga cuidado en su manejo.

002-00080-00

08/18/2021 Rev. A3


PDFlib PDI 9.3.1-i (macOS (arm64)) Serif Affinity Publisher 1.10.0