Delta DOP-107H Series Instruction Sheet
Model: DOP-107H
Manufacturer: Delta Electronics Inc.
Address: No.18, Xinglong Rd., Taoyuan City 33068, Taiwan
Document Date: 2021-07-09
General Precautions
Thank you for purchasing this product. This DOP-107H instruction sheet provides information for the DOP-107H series HMI. Before using this product, read through this instruction sheet carefully to ensure the correct use of the product. Keep this sheet handy for quick reference whenever needed.
- Install the product in an indoor environment which is free of vapor, corrosive and inflammable gas.
- Refer to the wiring diagram when connecting the wires.
- Ensure this product is correctly grounded. The grounding method must comply with national standard guidelines (refer to NFPA 70: National Electrical Code, 2005 Ed.).
- Do not change the wiring when power is on.
- Do not touch the power supply when power is on, or it may cause electric shock.
- When the HMI displays a low power notification and requires a battery change, contact the local distributor or Delta Customer Service Center for the replacement. Do not change the batteries by yourself.
- If you have any inquiry during operation, contact the local distributors or Delta Customer Service Center. The instruction sheet may be revised without prior notice. Contact distributors or download the latest version from the Delta website (http://www.deltaww.com).
Safety Precautions
Pay attention to the following safety precautions during installation, wiring, operation, maintenance, and inspection.
Installation
DANGER
- Comply with the instructions specified in the user manual for installation, or it may cause damage to the equipment.
- Avoid exposing the product to an environment containing vapor, corrosive gas, inflammable gas, or other foreign matter, or it may cause product damage, electric shock, fire, or explosion.
- Do not install the HMI in an environment where the ambient temperature exceeds the specified range, or it may cause abnormal operation or product damage.
- This product has the approval of KC Class A (for commercial devices), which is designed for commercial or industrial use, rather than for domestic use. If you have unintentionally purchased or sold the HMI products, replace them with products having the approval of KC Class B (for domestic use).
- Do not install the HMI to the machinery that may cause personnel injury, equipment damage, or emergency stop.
Wiring
DANGER
- Connect the ground terminals to a class-3 ground system. Ground resistance should not exceed 1000 Ω. Improper grounding may cause communication error, electric shock, or fire.
- Do not connect other wire rods to extend the cable length, or it may cause poor communication or malfunction.
Operation
WARNING
- Program the HMI screens with the DOPSoft software. If the HMI is not well-programmed, it may cause abnormal operation. To avoid personnel injury or equipment damage during operation, ensure the communication error occurring between the HMI and controller or equipment does not cause malfunction when programming the HMI screens.
- Back up the programmed HMI screens and programs to avoid unexpected data loss.
- Place the HMI on a flat surface or hang it with the hook on its back to prevent it from falling and thus crashing.
- Do not change the wiring when power is on, or it may cause electric shock or personnel injury.
- Do not touch the panel with sharp objects, or it may make a dent in the panel, resulting in abnormal operation of the HMI.
Maintenance and Inspection
STOP
- Do not touch the internal parts of the HMI, or it may cause electric shock or product damage.
- Do not touch the wiring terminals within 10 minutes after turning off the power. The residual voltage may cause electric shock.
Model Explanation
The model number is explained as follows:
Component | Explanation |
---|---|
DOP | Delta Operation Panel (HMI) |
1 | Series: 100 series HMI |
07 | Panel size: 7.0" |
HE/HS | Type: HE (Ethernet), HS (Standard) |
4 | Display resolution: WVGA |
6/7 | Code: 6 (15 Keys), 7 (21 Keys) |
5/A | Cable length: 5 (5 m), A (10 m) |
ZM/ZD | Connector: D-SUB connector |
Part Descriptions
Diagrams showing front, rear, and bottom views of the DOP-107H series with numbered parts are provided. Key numbered parts include:
- (1) Power indicator
- (2) Emergency stop switch
- (3) MPG (Manual Pulse Generator)
- (4) Auxiliary keyboard
- (5) Operation / display area
- (1) USB slave
- (2) SD card
- (1) 3-position operation switch
- (2) Bus
Installation Environment
For proper storage and to maintain warranty coverage when the product is not in use:
- Store the product in a dust-free and dry place.
- Store within an ambient temperature of -10°C to +60°C (14°F to 140°F).
- Store within a relative humidity range of 10% to 90% RH (non-condensing).
- Avoid storing in an environment containing corrosive gas and liquids.
- Properly wrap the product and place it on a shelf or platform.
The suitable installation environment should be a location that is:
- Free of devices that generate excessive heat.
- Free of water, vapor, dust, and oily dust.
- Free of corrosive and inflammable gas and liquids.
- Free of airborne dust and metal particles.
- Free of vibration and electronic interference.
This product must be used at an altitude below 2,000 m (6,561.68 feet).
Wiring
D-SUB Connector Wiring
Pin assignment for DOP-107HE42xZM/DOP-107HE46xZM/DOP-107HE47xZD series (D-SUB 25-pin):
Pin | Function |
---|---|
1 | LAN RD+ |
2 | LAN RD- |
3 | Reserved |
7 | Emergency stop - NO(A) |
8 | Emergency stop - NO(A) |
9 | Emergency stop - NC(B) |
10 | Emergency stop - NC(B) |
13 | 0Vdc input (use SELV power supply, isolated from MAINS by double insulation) |
14 | LAN TD+ |
15 | LAN TD- |
18 | External power input of MPG |
20 | Output point A of MPG |
21 | Output point B of MPG |
22 | 3-position operation switch - NO(A) |
23 | 3-position operation switch - NO(A) |
25 | 24Vdc input (use SELV power supply, isolated from MAINS by double insulation) |
DOP-107HS42x / DOP-107HS46x Series Cable Definition
Bare Wire Color | Cable Code | Function |
---|---|---|
White and orange | A | RS422 TX+ / RS485 D+ |
White and black | SG | Signal Ground (RS422, RS485) |
White and green | B | RS422 RX+ (labeled as "12") |
Brown | - | 3-position operation switch – NO(A) |
Orange | A | RS422 TX-/ RS485 D- |
Green | B | RS422 RX- |
White and brown | - | 3-position operation switch - NO(A) |
Red | - | 24VDC input (use SELV power supply, isolated from MAINS by double insulation) |
Black | - | 0VDC input (use SELV power supply, isolated from MAINS by double insulation) |
White | - | FGND power ground (use SELV power supply, isolated from MAINS by double insulation) |
Yellow | C | DOP-107HS46x only: output point A of MPG |
White and yellow | C | DOP-107HS46x only: output point B of MPG |
White and purple | D | Emergency stop - NC(B) |
White and green | D | Emergency stop - NC(B) |
White and red | - | DOP-107HS46x only: external power input of MPG |
Blue | E | Emergency stop - NC(B) |
White and blue | E | Emergency stop - NC(B) |
DOP-107HE46x Series Cable Definition
Bare Wire Color | RJ45 Pin | Function |
---|---|---|
White and black | Pin 1 | LAN RD+ |
White and black | Pin 3 | Reserved |
Brown | Pin 2 | LAN TD+ |
Brown | - | 3-position operation switch - NO(A) |
Orange | Pin 6 | LAN RD- |
Green | Pin 5 | LAN TD- |
White and brown | - | 3-position operation switch - NO(A) |
Red | - | 24VDC input (use SELV power supply, isolated from MAINS by double insulation) |
Black | - | 0VDC input (use SELV power supply, isolated from MAINS by double insulation) |
White | - | FGND power ground (use SELV power supply, isolated from MAINS by double insulation) |
Yellow | C | DOP-107HE46x only: output point A of MPG |
White and yellow | C | DOP-107HE46x only: output point B of MPG |
White and purple | D | Emergency stop - NC(B) |
White and green | D | Emergency stop - NC(B) |
White and red | - | DOP-107HE46x only: external power input of MPG |
Blue | E | Emergency stop - NC(B) |
White and blue | E | Emergency stop - NC(B) |
Communication Wiring Precautions
- Ensure the ground circuit is correct to avoid poor communication.
- To prevent excessive interference from causing abnormal operation of the HMI, place the communication cable, all power cables, and the motor power cable in separate conduits.
Basic Inspection
Item | Content |
---|---|
General inspection | Periodically check if the screws are securely tightened at the connection between the HMI and equipment. If the HMI is installed in a location containing dust or harmful gas, take precautions to prevent the dust and harmful gas from entering the HMI. |
Inspection before operation (without power) | Ensure the communication wiring is correct, or it may cause abnormal operation. Ensure there are no electrically conductive objects, such as screws or sheet metal, or inflammable objects inside or near the HMI. Reduce electromagnetic interference if there is electromagnetic interference with peripheral devices. |
Inspection before operation (power is applied) | Ensure the external voltage level for the HMI is correct. Check if the power indicator is enabled. Check if the communication among equipment is functioning normally. If the HMI operates abnormally, contact the local distributors or Delta Customer Service Center. |
MPG (Manual Pulse Generator) Output Description
Electrical Specifications:
- Input voltage (white and red wire): DC 5V +/-5% or DC 24V +/- 5%
- Output current: 20 mA (Max.) for DC 5V, 30 mA (Max.) for DC 24V
Notes:
- If connecting more than one device for MPG control is required, connect them according to the electrical specifications for MPG output to avoid malfunction.
- DC 5V and DC 24V devices that receive pulses are supported. Ensure the device complies with the required voltage, or it may cause damage to the equipment.
Applicable Models: DOP-107HS46x, DOP-107HE46x, DOP-107HE46xZM
Note: The MPG function is not available on DOP-107HE42x, DOP-107HS42x, and DOP-107HE42xZM models.
MPG Specifications:
- Rated voltage: < DC 24V
- Resolution: 50 (P/R)
- Output waveform: Square wave
- Output phase: A, B
- Phase difference between A and B: 90° ± 45°
- Maximum frequency response: 200 Hz
Hardware Specifications
Specification | DOP-107HS42x | DOP-107HS46x | DOP-107HE42x | DOP-107HE46x | DOP-107HE42xZM | DOP-107HE46xZM | DOP-107HE47xZD |
---|---|---|---|---|---|---|---|
Panel type | 7" TFT LCD (65535 colors) | ||||||
Resolution | 800 x 480 pixels | ||||||
Display | LED backlight (half-life under room temperature 25°C > 20,000 hours) | ||||||
Display size | 154.08 x 85.92 mm | ||||||
CPU | ARM Cortex-A8 (800 MHz) | ||||||
Flash ROM | 256 Mbytes | ||||||
RAM | 256 Mbytes | ||||||
Non-volatile memory | 32 Kbytes | ||||||
Touch panel | 4-wire resistive touchscreen (> 10,000,000 operated) | ||||||
Buzzer | Multi-tone frequency (2 to 4 kHz) / 80 dB | ||||||
Network interface | 10/100 Mbps auto-detection (built-in isolated power circuit) | ||||||
Serial communication port | RS422/RS485 | ||||||
Memory card | SD/SDHC | ||||||
USB | 1 USB client Ver 2.0 | ||||||
Auxiliary Keyboard | DOP-107HE47xZD: 21 Function keys; Others: 15 Function keys | ||||||
Cable length | 5 m (when end of model name = 5), 10 m (when end of model name = A) | ||||||
Calendar | Built-in | ||||||
Cooling method | Natural cooling | ||||||
Safety approval | CE (Note 3) | ||||||
Protection rating | IP54 | ||||||
Operating voltage | DC +24V (±15%) (built-in isolated power circuit) (Note 2) | ||||||
Leakage current withstand | AC500V for one minute (between DC24 and FG terminals) | ||||||
Power consumption | 4.896 W (Note 4) | ||||||
Backup battery | 3V lithium battery CR2450 × 1 | ||||||
Backup battery life | About 5 years or more at 25°C (77°F) (subject to operation temperature and condition) | ||||||
Operation temperature | 0°C to 40°C (32°F to 104°F) | ||||||
Storage temperature | -10°C to +60°C (14°F to 140°F) | ||||||
Operating environment | 10% to 90% RH [0 to 40°C (32 to 104°F)], 10% to 55% RH [41 to 50°C (105.8 to 122°F)], pollution degree: 2 | ||||||
Vibration resistance | Conforms to IEC61131-2: continuous vibration 5 Hz to 8.3 Hz with amplitude 3.5 mm; 8.3 Hz to 150 Hz with amplitude 1G | ||||||
Shock resistance | Conforms to IEC60068-2-27: 11 ms, 15G Peak, in X, Y, Z directions each for 6 times | ||||||
Dimensions (W) x (H) x (D) mm | 257.4 x 170.3 x 71.8 (emergency stop switch and hook included) | ||||||
Weight | 750 g (cable excluded) |
Notes on Specifications:
- The half-life of the backlight is defined as the maximum luminance being reduced by 50% when the maximum drive current is supplied to the HMI. The life of LED backlight shown here is estimated at the room temperature of 25°C (77°F) with ambient humidity.
- The withstand voltage of the isolated power circuit is 1500V peak for 1 minute.
- The certification for some models is under application. Contact the local distributor for the certificated models.
- The HMI power consumption is the power consumed when the HMI is not connecting with other peripheral devices. To ensure normal operation of the HMI, the recommended capacity of the power supply is 1.5 to 2 times of the specified power consumption.
- Isolated power supply unit is suggested.
- You can download the DOP-107H series programming software DOPSoft, user manual, and HMI installation sheet from Delta's website. The instruction sheet may be revised without prior notice. Download the latest version from the Delta website (http://www.deltaww.com).
- The DOP-107H series products can be used with industrial automation equipment. Read through this instruction sheet carefully and install the product according to the instructions to avoid danger.
- Cleaning method: use a dry cloth to clean the product.
- For repair and maintenance, contact Delta Electronics, Inc. Address: No. 18, Xinglong Rd., Taoyuan City, Taiwan. TEL: +886-3-3626301.