ZTE Corporation MF296C 4G Wireless Router with WiFi, NFC, GSM, WCDMA, and LTE SRQ-MF296C SRQMF296C mf296c
Certificate #5505.02 TEST REPORT FOR GSM TESTING Report No.: SRTC2022-9004(F)- 22080401(A) Product Name: 4G Wireless Router Product Model: MF296C Applicant: ZTE Corporation Manufacturer: ZTE Corporation Specification: FCC Part 24E, Part 22H, Part 2 (2021) FCC ID: SRQ-MF296C The State Radio_monitoring_center Testing Center (SRTC) 15th Building, No.30 Shixing Street, Shijingshan District, Beijing, P.R.China Tel: 86-10-57996183 Fax: 86-10-57996388 No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C CONTENTS 1. GENERAL INFORMATION................................................................................................................................... 2 1.1 Notes of the test report................................................................................................................................. 2 1.2 Information about the testing laboratory....................................................................................................2 1.3 Applicant's details..........................................................................................................................................2 1.4 Manufacturer's details...................................................................................................................................2 1.5 Test Environment.......................................................................................................................................... 2 2 DESCRIPTION OF THE DEVICE UNDER TEST...............................................................................................3 2.1 Final Equipment Build Status...................................................................................................................... 3 2.2 Support Equipment....................................................................................................................................... 3 3 REFERENCE SPECIFICATION............................................................................................................................ 4 4 KEY TO NOTES AND RESULT CODES.............................................................................................................4 5 RESULT SUMMARY............................................................................................................................................... 5 6 TEST RESULT..........................................................................................................................................................7 6.1 RF Power Output...........................................................................................................................................7 6.2 Effective Radiated Power and Effective Isotropic Radiated Power...................................................... 8 6.3 Occupied Bandwidth..................................................................................................................................... 9 6.4 Emission Bandwidth-.................................................................................................................................. 10 6.5 Spurious Emissions at antenna terminal.................................................................................................11 6.6 Band Edges Compliance............................................................................................................................12 6.7 Frequency Stability......................................................................................................................................13 6.8 Radiated Spurious Emissions................................................................................................................... 14 6.9 Peak-Average Ratio....................................................................................................................................16 7 MEASUREMENT UNCERTAINTIES..................................................................................................................17 8 TEST EQUIPMENTS............................................................................................................................................. 18 APPENDIX A TEST DATA OF CONDUCTED EMISSION............................................................................. 19 APPENDIX B TEST DATA OF RADIATED EMISSION.................................................................................. 63 The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 1 of 64 V3.0.0 1. GENERAL INFORMATION No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C 1.1 Notes of the test report The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written permission of The State Radio_monitoring_center Testing Center (SRTC).The test results relate only to individual items of the samples which have been tested. The certification and accreditation identifiers used in this report shall not be applicable to the tested or calibrated samples thereof. The manufacturer shall not mark the tested samples or items (or a separate part of the item) with the identifiers of certification and accreditation to mislead relevant parties about the tested samples or items. 1.2 Information about the testing laboratory Company: Test Site 1: Test Site 2: City: Country or Region: Contacted person: Tel: Fax: Email: Designation Number: Registration number: The State Radio_monitoring_center Testing Center (SRTC) 15th Building, No.30 Shixing Street, Shijingshan District No.80, Zhaojiachang, Beizang, Daxing District Beijing P.R.China Liu Jia +86 10 57996183 +86 10 57996388 liujiaf@srtc.org.cn CN1267 239125 1.3 Applicant's details Company: Address: ZTE Corporation ZTE Plaza, #55 Keji Road South, Hi-Tech, Industrial Park, Nanshan District,Shenzhen, Guangdong, 518057, P.R.China 1.4 Manufacturer's details Company: Address: ZTE Corporation ZTE Plaza, #55 Keji Road South, Hi-Tech, Industrial Park, Nanshan District,Shenzhen, Guangdong, 518057, P.R.China 1.5 Test Environment Date of Receipt of test sample at SRTC: Testing Start Date: Testing End Date: 2022-08-04 2022-08-05 2022-08-31 The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 2 of 64 V3.0.0 Environmental Data: Ambient: Maximum Extreme: Minimum Extreme: Normal Supply Voltage (V d.c.): Maximum Extreme Supply Voltage (V d.c.): Minimum Extreme Supply Voltage (V d.c.): No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C Temperature (°C) 25 55 -20 Humidity (%) 40 ----- 12.0 13.2 10.8 2 DESCRIPTION OF THE DEVICE UNDER TEST 2.1 Final Equipment Build Status Frequency Range: GSM850: Tx:824~849MHz Rx:869~894MHz PCS1900: Tx:1850~1910MHz Rx:1930~1990MHz Modulation Type: GPRS/EDGE Emission Designator: 300KGXW/300KG7W Duplex Mode: Duplex Spacing: Antenna Type: Antenna Gain: Power Supply: Software Revision: Hardware Revision: IMEI: FDD GSM850:45MHz PCS1900:80MHz Internal antenna GSM850: 0.6dBi/PCS1900: 1.9dBi ERP = EIRP(Power+Gain) 2.15 (dB) Charger CR_LAMF296CV1.0.0B01 mp6A 860389060007859 2.2 Support Equipment The following support equipment was used to exercise the DUT during testing: N/A The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 3 of 64 V3.0.0 3 REFERENCE SPECIFICATION No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C Specification FCC Part2 FCC Part22 FCC Part24 ANSI C63.26 KDB 971168 D01 TIA-603-E-2016 Version 2021 2021 2021 2021 April 9, 2018 March 2016 Title Frequency allocations and radio treaty matters; general rules and regulations Public mobile services Personal communications services American national standard for compliance testing of transmitters used in licensed radio services Measurement guidance for certification of licensed digital transmitters Land Mobile FM or PM Communications Equipment Measurement and Performance Standards 4 KEY TO NOTES AND RESULT CODES The following are the definition of the test result. Code Meaning PASS Test result shows that the requirements of the relevant specification have been met. FAIL Test result shows that the requirements of the relevant specification have not been met. NT Normal Temperature NV Nominal voltage HV High voltage LV Low voltage The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 4 of 64 V3.0.0 5 RESULT SUMMARY No. Test case 1 RF Power Output Effective Radiated Power and 2 Effective Isotropic Radiated Power 3 Occupied Bandwidth 4 Emission Bandwidth Spurious Emissions 5 at antenna terminals 6 Band Edges Compliance 7 Frequency Stability 8 Peak-Average Ratio No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C FCC reference 2.1046 22.913(a)(5)/24.232(c) 2.1049 2.1049 2.1051/22.917(a)/24.238(a) 2.1051/22.917(a)/24.238(a) 2.1055/22.355/24.235 24.232(d) Verdict Pass Pass Pass Pass Pass Pass Pass Pass Test Site 1: 15th Building, No.30 Shixing Street, Shijingshan District This Test Report Is Approved by: Mr. Peng Zhen Tested and Issued by: Mr. Liu Ce Review by: Mr. Li Bin Approved date: 20220901 The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 5 of 64 V3.0.0 No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C No. Test case 9 Radiated Spurious Emissions FCC reference 2.1053/22.917(a)/24.238(a) Test Site 2: No.80, Zhaojiachang, Beizang, Daxing District Verdict Pass This Test Report Is Approved by: Mr. Liu Wei Tested and Issued by: Mr. Dong Qifeng Review by: Mr. Guo Yu Approved date: 20220901 The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 6 of 64 V3.0.0 6 TEST RESULT 6.1 RF Power Output Rule Part(s) FCC Part 2.1046 Test Setup: EUT RF output No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C GSM Mobile Station Tester Test procedure: After a radio link has been established between EUT and Tester, the output power of the cell signal of the testing equipment will be decreased until the output power of the EUT reach a maximum value. Then the test data can be read at the tester screen. The loss between RF output port of the EUT and the input port of the tester will be taken into consideration. The measurement will be conducted at three channels (Low, Middle and High channels) Limits: No specific conduct power requirements in part 2.1046. Test result: The test results are shown in Appendix A. The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 7 of 64 V3.0.0 No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C 6.2 Effective Radiated Power and Effective Isotropic Radiated Power Rule Part(s) FCC Part 22.913(a)(5)/Part 24.232(c) Test setup: EUT RF output Mobile Station Tester Test procedure: KDB 971168 D01 v03r01 Section 5.6 Test Settings Subclause 5.2.5.5 of ANSI C63.26-2015 is applicable, along with the following provisions. For personal/portable radios utilizing an integral antenna, the factor LC is typically negligible. However, in a fixed station transmit system that utilizes a long cable run between the transmitter and the transmitting antenna, this factor can be significant. The minimum cable loss should be used in this equation. The relevant equation for determining the ERP or EIRP from the conducted RF output power measured is: ERP/EIRP = PMeas LC + GT Where: ERP/EIRP = effective or equivalen radiated power, respectively (expressed in the same units as PMeas, typically dBW or dBm) PMeas = measured transmitter output power or PSD, in dBW or dBm LC = signal attenuation in the connecting cable between the transmitter and antenna in dB GT = gain of the transmitting antenna, in dBd (ERP) or dBi (EIRP) Limits for GSM850: Operation Mode Power Step E.R.P. (dBm) GPRS 3 38.45 EDGE 6 38.45 Limits for PCS1900: Operation Mode Power Step E.I.R.P. (dBm) GPRS 3 33 EDGE 5 33 Test result: The test results are shown in Appendix A. The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 8 of 64 V3.0.0 No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C 6.3 Occupied Bandwidth Rule Part(s) Part 2.1049 Test Setup: EUT RF output Power Divider GSM Mobile Station Tester Spectrum Analyzer Test procedure: KDB 971168 D01 v03r01 Section 4.2 Test Settings 1. The signal analyzer's automatic bandwidth measurement capability was used to perform the 99% occupied bandwidth and the 26dB bandwidth. The bandwidth measurement was not influenced by any intermediate power nulls in the fundamental emission. 2. RBW = 1 5% of the expected OBW 3. VBW 3 x RBW 4. Detector = Peak 5. Trace mode = max hold 6. Sweep = auto couple 7. The trace was allowed to stabilize 8. If necessary, steps 2 7 were repeated after changing the RBW such that it would be within 1 5% of the 99% occupied bandwidth observed in Step 7 Limits: No specific occupied bandwidth requirements in part 2.1049 Test result: The test results are shown in Appendix A. The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 9 of 64 V3.0.0 No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C 6.4 Emission Bandwidth- Rule Part(s) Part 2.1049 Test Setup: EUT RF output Power Divider GSM Mobile Station Tester Spectrum Analyzer Test procedure: KDB 971168 D01 v03r01 Section 4.2 Test Settings 1. The signal analyzer's automatic bandwidth measurement capability was used to perform the 26dB occupied bandwidth and the 26dB bandwidth. The bandwidth measurement was not influenced by any intermediate power nulls in the fundamental emission. 2. RBW = 1 5% of the expected OBW 3. VBW 3 x RBW 4. Detector = Peak 5. Trace mode = max hold 6. Sweep = auto couple 7. The trace was allowed to stabilize 8. If necessary, steps 2 7 were repeated after changing the RBW such that it would be within 1 5% of the emission bandwidth observed in Step 7 Limits: No specific occupied bandwidth requirements in part 2.1049 Test result: The test results are shown in Appendix A. The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 10 of 64 V3.0.0 No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C 6.5 Spurious Emissions at antenna terminal Rule Part(s) FCC Part 2.1053/22.917 (a)/ 24.238(a) Test Setup: EUT RF output Power Divider GSM Mobile Station Tester Spectrum Analyzer Test procedure: KDB 971168 D01 v03r01 Section 6.0 Test Settings 1. Start frequency was set to 30MHz and stop frequency was set to 10GHz for Cell, 20GHz for PCS 2. RBW=100 kHz (For below 1GHz), 1MHz (For above 1GHz) 3. VBW 3 x RBW 4. Detector = RMS 5. Trace mode = trace average for continuous emissions, max hold for pulse emissions 6. Sweep time = auto couple 7. The trace was allowed to stabilize Limits: The minimum permissible attenuation level of any spurious emission is 43+log 10(P [Watts]), where P is the transmitter power in Watts. Test result: The test results are shown in Appendix A. The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 11 of 64 V3.0.0 No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C 6.6 Band Edges Compliance Rule Part (s) FCC Part 2.1051/ 22.917(a) /Part 24.238(a) Test Setup: EUT RF output Power Divider GSM Mobile Station Tester Spectrum Analyzer Test procedure: KDB 971168 D01 v03r01 Section 6.0 Test Settings 1. Start and stop frequency were set such that the band edge would be placed in the center of the plot 2. Span=2MHz 3. RBW > 1% of the emission bandwidth 4. VBW > 3 x RBW 5. Detector = RMS 6. Number of sweep points 2 x Span/RBW 7. Trace mode = trace average for continuous emissions, max hold for pulse emissions 8. Sweep time = auto couple 9. The trace was allowed to stabilize Limit: The minimum permissible attenuation level of any spurious emission is 43+log10 (P [Watts]), where P is the transmitter power in Watts. Test result: The test results are shown in Appendix A. The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 12 of 64 V3.0.0 6.7 Frequency Stability Rule Part(s) FCC Part 2.1055/22.355 /Part 24.235 Test setup: Climate Chamber EUT No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C GSM Mobile Station Tester DC Power Supply Test Procedure: ANSI/TIA-603-E-2016 Test Settings 1. The carrier frequency of the transmitter is measured at room temperature (20°C to provide a reference). 2. The equipment is turned on in a "standby" condition for fifteen minutes before applying power to the transmitter. Measurement of the carrier frequency of the transmitter is made within one minute after applying power to the transmitter. 3. Frequency measurements are made at 10°C intervals ranging from -30°C to +50°C (The temperature range can be declared by the manufacturer). A period of at least one half-hour is provided to allow stabilization of the equipment at each temperature level. Limits: For Part 22, the frequency stability of the transmitter shall be maintained within±0.00025% (±2.5 ppm) of the center frequency. For Part 24, the frequency stability shall be sufficient to ensure that the fundamental emission stays within the authorized frequency block. Test result: The test results are shown in Appendix A. The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 13 of 64 V3.0.0 6.8 Radiated Spurious Emissions Rule Part(s) FCC Part2.1053/ 22.917(a)/Part 24.238(a) Test Setup: No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C Step 1 Step 2 The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 14 of 64 V3.0.0 No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C Test procedure: The measurements procedures in TIA-603-E-2016 are used. The spectrum was scanned from 30MHz to the 10th harmonic of the highest frequency generated within the equipment. Step 1: The measurement is carried out in the chamber. EUT was placed on a 0.8m (f<1GHz)/ 1.5m (f>1GHz) high non-conductive table at a 3 meters test distance from the test receive antenna. A receiving antenna was placed on the antenna mast 3 meters from the EUT. The height of receiving antenna from 1m to 4m and varies in certain range to find the maximum power value. A radio link shall be established between EUT and Tester. The output power of the cell signal of the tester will be decreased until the output power of the EUT reach a maximum value. A peak detector is used and RBW is set to 100 kHz (f<1GHz)/1MHz (f>1GHz). The antenna shall be performed under horizontal and vertical polarization. The turn table shall be rotated from 0 to 360 degrees for detecting the maximum power value on spectrum analyzer or receiver. The spectrum analyzer scans from 30MHz to 10th harmonic of the carrier. A notch filter is necessary in the band near to the carrier frequency. A high pass filter is needed to avoid the distortion of the testing equipment in the band above the carrier frequency. Step 2: A log-periodic antenna or double-ridged waveguide horn antenna shall be substituted in place of the EUT. The log-periodic antenna will be driven by a signal generator and the level will be adjusted till the same power value on the spectrum analyzer or receiver. The level of the spurious emissions can be calculated through the level of the signal generator, cable loss, the gain of the substitution antenna and the reading of the spectrum analyzer or receiver. A power (Pmea) is applied to the input of the substitution antenna, and adjusts the level of the signal generator output until the value of the receiver reach the previously recorded (Pr). The power of signal source (Pmea) is recorded. The test should be performed by rotating the test item and adjusting the receiving antenna polarization. A "reference path loss" should be calculated after test. The attenuation of "reference path loss" is the cable loss between the Signal Source with the Substitution Antenna (Pca) and the Substitution Antenna Gain (Ga). Calculation procedure: The data of cable loss and antenna gain has been calibrated in full testing frequency range before the testing. The power of the Radiated Spurious Emissions is calculated by adding the cable loss and antenna gain. The basic equation with a sample calculation is as followed: Power (EIRP) = Pmea+ Pca + Ga This value is EIRP since the measurement is calibrated using an antenna of known gain (2.15dB) and known input power. ERP can be calculated from EIRP by subtracting the gain of the dipole, ERP = EIRP 2.15 (dB). Assumed the power of signal source record is -20dBm. A cable loss of -30dB, and an antenna gain of 11dB are added. P=Pmea+Pca+Ga=(-20dBm)+(-30dB)+(11dB)= -39dBm Note: We tested both horizontal and vertical polarization, but only the largest numerical polarity of the two polarities was recorded in the final report. Test result: The test results are shown in Appendix B. The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 15 of 64 V3.0.0 6.9 Peak-Average Ratio Rule Part(s) FCC Part 24.232(d) Test Setup: EUT RF output Power Divider No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C GSM Mobile Station Tester Spectrum Analyzer Test procedure: KDB 971168 D01 v03r01 Section 5.7.1 Test settings: 1. The signal analyzer's CCDF measurement profile is enabled 2. Frequency = carrier center frequency 3. Measurement BW > Emission bandwidth of signal 4. The signal analyzer was set to collect one million samples to generate the CCDF curve 5. The measurement interval was set depending on the type of signal analyzed. For continuous signals (>98% duty cycle), the measurement interval was set to 1ms. For burst transmissions, the spectrum analyzer is set to use an internal "RF Burst" trigger that is synced with an incoming pulse and the measurement interval is set to less than the duration of the "on time" of one burst to ensure that energy is only captured during a time in which the transmitter is operating at maximum power Limits: the peak-to-average ratio (PAR) of the transmission may not exceed 13 dB. Test result: The test results are shown in Appendix A The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 16 of 64 V3.0.0 7 MEASUREMENT UNCERTAINTIES No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C Items RF Power Output Effective Radiated Power and Effective Isotropic Radiated Power Occupied Bandwidth Emission Bandwidth Peak-Average Ratio Frequency Stability Band Edges Compliance Spurious Emissions at antenna terminal Radiated Emission Measurement Uncertainty 0.6 dB 0.6 dB 3kHz 3kHz 0.8dB 48Hz 1.2dB 9kHz~2GHz 2G~3.6GHz 3.6G~8GHz 8G~12.75GHz 30MHz200MHz 200MHz1GHz 1GHz18GHz 18GHz~40GHz 1.2dB 1.4dB 2.2dB 2.7dB 4.88dB 4.87dB 4.58dB 4.35dB The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 17 of 64 V3.0.0 8 TEST EQUIPMENTS No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C No. Name/Model Manufacturer S/N Calibration Date 1 Mobile Station Tester / MT8820C Anritsu 6201300660 2022.06.21 2 Radio Communication Station / CMW500 R&S 161702 2022.06.21 3 Spectrum Analyzer / FSV40 R&S 101065 2022.06.21 4 Spectrum Analyzer / N9020A Agilent MY48010771 2022.05.18 5 Power Divider / 11667A HP 19632 2022.06.21 6 DC Power Supply / E3645A Agilent MY40000741 2022.04.22 7 Temperature chamber / SH241 ESPEC 92013758 2022.06.21 8 Fully-Anechoic Chamber / 12.65m×8.03m×7.50m FRANKONIA ----- ----- 9 Semi-Anechoic/Chamber / 23.18m×16.88m×9.60m FRANKONIA --- ----- 10 Turn table Diameter:1m FRANKONIA ----- ----- 11 Turn table Diameter:5m FRANKONIA ----- ----- 12 Antenna master FAC(MA4.0) MATURO ----- ----- 13 Antenna master SAC(MA4.0) MATURO ----- ----- 14 Shielding room / 9.080m×5.255m×3.525m FRANKONIA ----- ----- 15 Double-Ridged Waveguide Horn Antenna / HF 907 R&S 100512 2022.06.21 16 Double-Ridged Waveguide Horn Antenna / HF 907 R&S 100513 2022.06.21 17 Ultra log antenna / HL562 R&S 100016 2022.06.21 18 Receive antenna /3160-09 SCHWARZ-BECK 002058-002 2022.06.21 19 EMI test receiver / ESI 40 R&S 100015 2022.06.21 20 EMI test receiver / ESCS30 R&S 100029 2022.06.21 21 Receive antenna / HL562 R&S 100167 2022.06.21 22 AMN / ENV216 R&S 3560.6550.12 2022.06.21 23 FCC auto test system / RT9100L-2 Radiosky V1.05 / 24 EMI test software / EMC32 R&S V10.20.01 / Calibration Due Date 2023.06.20 2023.06.20 2023.06.20 2023.05.17 2023.06.20 2023.04.21 2023.06.20 ----- ----- ----------------- ----- 2023.06.20 2023.06.20 2023.06.20 2023.06.20 2023.06.20 2023.06.20 2023.06.20 2023.06.20 / / The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 18 of 64 V3.0.0 No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C APPENDIX A TEST DATA OF CONDUCTED EMISSION GSM850 1. RF Power Output GSM850 GPRS Measured Power: Carrier frequency (MHz) Channel No. 824.2 128 836.4 189 848.8 251 824.2 128 836.4 189 848.8 251 EGPRS (8PSK) Measured Power: Carrier frequency (MHz) Channel No. 824.2 128 836.4 189 848.8 251 824.2 128 836.4 189 848.8 251 TX Mode 4Down1Up 3Down2Up TX Mode 4Down1Up 3Down2Up RF Power Output (dBm) 32.22 32.36 32.51 32.24 32.09 32.24 RF Power Output (dBm) 32.29 32.43 32.56 32.15 32.29 32.43 The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 19 of 64 V3.0.0 2. Occupied Bandwidth GSM850 GPRS MODE: Carrier frequency (MHz) 824.2 836.4 848.8 EGPRS (8PSK) MODE: Carrier frequency (MHz) 824.2 836.4 848.8 Channel No. 128 189 251 Channel No. 128 189 251 No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C Bandwidth of 99% Power (kHz) 247.47 235.89 250.36 Bandwidth of 99% Power (kHz) 244.57 235.89 240.23 The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 20 of 64 V3.0.0 GSM850 GSM MODE: GPRS MODE: No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C Channel 128 Channel 189 The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 21 of 64 V3.0.0 No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C EGPRS (8PSK) MODE: Channel 251 Channel 128 The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 22 of 64 V3.0.0 No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C Channel 189 Channel 251 The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 23 of 64 V3.0.0 3. Emission Bandwidth GSM850 GPRS MODE: Carrier frequency (MHz) 824.2 836.4 848.8 EGPRS (8PSK) MODE: Carrier frequency (MHz) 824.2 836.4 848.8 Channel No. 128 189 251 Channel No. 128 189 251 No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C Bandwidth of -26dB (kHz) 314.00 316.90 305.40 Bandwidth of -26dB transmitter power(kHz) 311.10 303.90 303.90 The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 24 of 64 V3.0.0 GSM850 GSM MODE: GPRS MODE: No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C Channel 128 Channel 189 The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 25 of 64 V3.0.0 No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C EGPRS (8PSK) MODE: Channel 251 Channel 128 The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 26 of 64 V3.0.0 No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C Channel 189 Channel 251 The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 27 of 64 V3.0.0 4. Spurious Emissions at antenna terminal GSM850 GPRS MODE: No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C Channel 128 Channel 128 The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 28 of 64 V3.0.0 No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C Channel 189 Channel 189 The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 29 of 64 V3.0.0 No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C Channel 251 EGPRS (8PSK) MODE: Channel 251 The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 30 of 64 V3.0.0 No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C Channel 128 Channel 128 The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 31 of 64 V3.0.0 No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C Channel 189 Channel 189 The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 32 of 64 V3.0.0 No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C Channel 251 Channel 251 The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 33 of 64 V3.0.0 5. Band Edges Compliance GSM850 GPRS MODE: No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C Channel 128 EGPRS (8PSK) MODE: Channel 251 The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 34 of 64 V3.0.0 No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C Channel 128 Channel 251 The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 35 of 64 V3.0.0 6. Frequency Stability GSM850 Temperature(°C) -20 -10 0 +10 +30 +40 +55 Voltage LV HV EGPRS (8PSK) MODE: Temperature(°C) -20 -10 0 +10 +30 +40 +55 Voltage LV HV Channel 128 0.003 0.006 0.006 -0.005 0.006 0.000 0.003 Channel 128 -0.008 -0.001 Channel 128 0.009 0.011 0.004 0.017 0.003 0.001 -0.003 Channel 128 0.005 -0.007 No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C Test Result (ppm)@NV Channel 189 0.009 0.006 0.010 0.007 0.009 0.005 0.012 Test Result (ppm)@NT Channel 189 -0.001 -0.008 Test Result (ppm)@NV Channel 189 0.017 0.002 0.015 0.011 0.011 0.005 0.001 Test Result (ppm)@NT Channel 189 0.011 0.005 Channel 251 0.006 0.004 0.001 -0.010 0.002 0.003 0.000 Channel 251 -0.014 -0.007 Channel 251 -0.006 0.001 -0.006 -0.004 -0.006 0.000 -0.003 Channel 251 -0.011 -0.013 The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 36 of 64 V3.0.0 7. Peak-Average Ratio GSM850 GSM MODE: GPRS MODE: No.: SRTC2022-9004(F)-22080401(A) FCC ID: SRQ-MF296C Channel 128 Channel 189 The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 37 of 64 V3.0.0