www.usa.siemens.com/services

4 30-year extended warranty program An extended warranty program that brings peace of mind and enhanced financial returns to your business. The Siemens LifeGuardTM high-voltage circuit breaker 30-year extended warranty program is a warranty

Siemens Psd02 Manual Pdf - A5E00074631-06EN PS2 Manual - Industry Support Siemens

PDF preview unavailable. Download the PDF instead.

hv-overview-brochure
Siemens Industry, Inc. 7000 Siemens Road Wendell, NC 27591
For more information, please contact our Customer Support Center. Phone: 1-800-333-7421
usa.siemens.com
Order No: EMTS-B40043-00-4AUS Printed in USA ©2017 Siemens Industry, Inc.

The technical data presented in this document is based on an actual case or on as-designed parameters, and therefore should not be relied upon for any specific application and does not constitute a performance guarantee for any projects. Actual results are dependent on variable conditions. Accordingly, Siemens does not make representations, warranties, or assurances as to the accuracy, currency or completeness of the content contained herein. If requested, we will provide specific technical data or specifications with respect to any customer's particular applications. Our company is constantly involved in engineering and development. For that reason, we reserve the right to modify, at any time, the technology and product specifications contained herein.

www.usa.siemens.com/services

www.usa.siemens.com/services
High-Voltage Products and Services
From 69kV to 800kV
Answers for infrastructure and cities

Product support for new and legacy equipment, retrofit solutions and replacement circuit breakers for most OEM brands.

As the supplier of OEM parts for your Allis-Chalmers and Siemens medium-voltage switchgear and breakers, Siemens is committed to supporting you with qualified parts and factory trained field service support throughout your products' life cycle.
With Siemens Energy Management Customer Services, an experienced, factory trained engineer who specializes in High Voltage SF6 breaker installations will be on site to provide technical assistance each step of the way.
Turnkey installation services can include replacement and disposal of an existing oil circuit breaker. Thousands of oil circuit breakers (OCBs) made by a variety of OEMs are nearing the end of their useful life. In addition to the high cost and difficulties of finding placement parts, environmental concerns have encouraged customers to replace these breakers with new Siemens SF6 breakers (SPS2, CPV2, and 3AT2).

Supporting Turnkey breaker installation/OCB changeouts Life-extension and uprate solutions Technical field assistance Turnkey maintenance and repair Testing services Current transformers (CTs) Replacement parts Replacement circuit breakers Replacement contactors Ground and test devices Training onsite or at our factory

2

Support Capabilities

Gas Insulated Circuit Breakers

Brand/Type

Model Operator

Siemens
Westinghouse Merlin Gerin

SPS2 SPS SPS1 3AT LPO SP

FA2-FA5 SE4 SE4 PH30 PH30 SA7

Spare Parts Uprate Available

a

a

a

a

a

a

a

a

a

Limited

Refurbished Equipment
a a a Limited

Field Service Training

a

a

a

a

a

a

a

a

a

a

Oil Breakers
Brand/Type Model
BZO Allis-Chalmers FZO
SDO

Operator PH33E-5, PH33T-5, PH33T-6
SE-3B/SE-3C

Spare parts

Uprate Available

Refurbished Equipment

a

a

a a

Field Service Training
a a a

Field Service
Choosing Siemens as your service partner is easy. You have a team of highly trained technicians and engineers, backed by the latest technology ad the resources of a global leader. Our technicians are committed to your success. They know your equipment and are focused on solving your most common and difficult challenges. What can be better than that?
Services include:
· Power transformer services · Power circuit breaker services · Medium-voltage switchgear services · High-voltage systems services · Protection and control services · Engineering and project management · Project planning and logistics · Installation and commissioning services · Preventative maintenance services · On-call maintenance agreements · Emergency services · Technical field assistance · Uprates, upgrades and life-extension solutions · After-market parts · T&D equipment training · Load-tap changer services of all manufacturers
and types

Training
Onsite training
Siemens can provide an experienced field engineer to bring technical, hands-on training in the environment that you are comfortable in. In this setting, maintenance technicians and asset owners can interact directly with the equipment as the instructor walks through maintenance and repair techniques. When required, we can provide additional learning materials and incorporate classroom instruction as part of the training.
Technical Field Assistance
When field service arises, either planned or unplanned, you can contract Siemens to provide a factory trained engineer to come onsite and assist your chosen contractors or maintenance crews with OEM experience to help you perform your work.
Factory Training
You will be hosted at one of our factories where subject matter experts are located, along with relevant equipment demos. Curriculum is designed to increase the knowledge of personnel responsible for handling, installing and maintaining the equipment. The program consists of classroom training and hands-on instruction.

3

LifeGuardTM High-voltage Circuit Breaker

30-year extended warranty program
An extended warranty program that brings peace of mind and enhanced financial returns to your business.
The Siemens LifeGuardTM high-voltage circuit breaker 30-year extended warranty program is a warranty extension and long-term maintenance program combined into a single offering. This offering may allow asset owners to capitalize the majority of the costs of ownership over a thirty-year period, assuming the circuit breaker expense may be included as part of a utility`s rate base. By being incorporated into the rate base rather than treated as a normal ownership expense, a utility is afforded the opportunity to obtain a rate of return on both the circuit breaker itself as well as the capitalized cost of ownership including maintenance. Depending upon the financial structure of a utility, the increase in rate of return on a typical high-voltage circuit breaker can be between 20 to 40 percent.
In addition to potential enhanced financial returns, Siemens performs all preventative and corrective maintenance associated with the life of the circuit breaker. Incorporated into the cost of the program is remote monitoring of the circuit breaker, which allows Siemens technicians to blend both time- and condition-based maintenance to assure circuit breaker serviceability. Annual reports are provided to the asset owner presenting circuit breaker performance parameters measured during the circuit breaker`s operation, as well as test results after major maintenance service is performed.
LifeGuardTM high-voltage circuit breaker extended warranty program can be easily added to cuircuit breakers purchased under a long-term purchase agreement, with circuit breakers automatically enrolled and covered by the program once commissioned into operation.
The basic extended warranty program covers all typical high-voltage circuit breaker applications, such as transmission and transformer protection, with special circuit breaker applications, such as cap bank or reactor switching, being available after technical review of operational and load characteristsics. The program covers all SPS2 circuit breaker ratings and associated mechanisms.

Benefits of the program:
· Preventative and corrective maintenance costs fixed for 30-year term of coverage · Capitalization of the program's costs allow enhanced rate of return on asset ownership · Future corrective maintenance cost risk is eliminated for the period of coverage · Siemens maintains inventory of parts to support maintenance programs · On-going reports of circuit breaker performance and maintenance performed provided annually · Can be added to high-voltage circuit breaker long-term purchasing agreements · High-voltage circuit breakers can be relocated and still covered under the program
In addition to providing factory-trained personnel to perform maintenance and the use of genuine Siemens parts, the data captured from the circuit breaker remote monitoring system provides additional insight into circuit breaker life-cycle management. Data and its related analysis can be prodvided by Siemens to better plan asset capital investment.
Term: Up to 30 years from installation
Coverage: Preventative and corrective maintenance
Product: Available for all Siemens SPS2 72 to 550kV live and dead tank high-voltage circuit breakers.

4

Maintenance and Upgrades

Model

Maintenance Intervals

Uprates Available

Operations Per Year

Upgrades Available

TCP 3000

·Pressure relief valve

Prevent leakage by replacing ``dart`` type relief valve with direct acting "ball"

type

·Power unit modification

Replace out-of-production Barnes pump with modern design

·Interrupting rating

·Dual trip coils

Many 121 145 kV TCP breakers were originally

Additional trip coils provide redundancy

12

designed for 40 kA. Siemens can increase this

·Current transformer (CT) covers

rating to 50 kA by adding line to ground

Prevent corrosion by replacing original steel plate with aluminum

capacitors.

·-40°F temperature operation

Improve operating temperature to -40°F by adding tank heaters

·Seismic rating

Upgrade breaker to meet seismic zone 3 or 4

·SF6 manifold
Upgrade SF6 manifold with sampling valve

SP/SPS 2000

8

·Interrupting rating
Many SP breakers were originally designed for 23 kA. Siemens can increase this rating to 31.5 kA by replacing the interrupter and adding a tank liner. Siemens can further increase this rating to 40 kA

·SF6 pressure monitoring
Several methods were applied to monitor gas pressure. The later design incorporated a temperature compensated pressure switch in conjunction with a lockout relay that prevents the breaker from operating while the pressure is below safe operating levels. Breakers with other methods can be upgraded to this functionality

by adding line to ground capacitors.

·Control cabinet anti-condensation

·Continuous circuit
Many SP breakers were originally designed for

Prevent corrosion in the control cabinet by adding an anticondensation heater assembly

1,200 amperes. Siemens can increase this rating to ·-40 °F temperature operation

2,000 or 3,000 amperes by changing a bushing Improve operating temperature to -40 °F by adding tank heaters

component and possibly the current transformers.

·Replacement porcelain bushings
SP breakers manufactured prior to 1988 utilized epoxy bushings. Siemens can

·Voltage rating

field install replacement porcelain bushings

It is possible to increase the voltage rating to 72 kV by adding voltage shields.

·Manifold assembly
Prevent corrosion and leakage on the manifold by replacing the original

stainless steel tubing with new copper tubing

SPS2

20-25 ·Some models can be uprated to 63kA by adding
capacitors.

5


Adobe PDF Library 15.0 Adobe InDesign CC 13.1 (Windows)