CA2500 2019 FDI Catalog - Functional Devices, Inc.

Information from: EnOcean Alliance & ENERGY STAR Building Upgrade Manual. 902 MHz • Maintenance-free. Flexibility of applications • Time saving.

PDF preview unavailable. Download the PDF instead.

CA2500 2019 FDI Catalog
TABLE OF CONTENTS
NEW & FEATURED PRODUCTS
RELAYS
10-15 AMP: 34 | 20-30 AMP: 36 | LATCHING: 38 | LOW INPUT / OPTOISOLATED: 39 POLARIZED / ALARM: 40 | DRY CONTACT INPUT: 41 | SPECIALTY PERIPHERAL CONTROLS: 42
NETWORK COMPATIBLE DEVICES
BACNET® : 47 | LONMARK® : 47 | WI-FI : 47 | MODBUS : 47
CURRENT SENSORS
SOLID & SPLIT CORE: 51 | TRANSDUCERS: 51 | T STYLE: 51 ENCLOSED & TRACK MOUNT RELAY AND SENSOR COMBINATIONS: 52
POWER SUPPLIES
40-100VA AC: 57 | 200-500VA AC: 57 | AC POWER SUPPLY KITS: 58 | DC: 58
TRANSFORMERS
U.S. MANUFACTURED: 62
POWER CONTROL
POWER CONTROL CENTERS: 69 | TRACK MOUNT CIRCUIT BREAKER SWITCHES: 69 PREPACKAGED SWITCHES: 69 | UPS POWER SUPPLY KITS: 69
WIRELESS DEVICES
WIRELESS RELAY TRANSCEIVERS & RECEIVERS : 73 | WIRELESS TRANSMITTERS: 73 WIRELESS VACANCY / OCCUPANCY SENSORS: 73
ENCLOSURES
PLASTIC: 77 | METAL: 77
ACCESSORIES
SUB-PANELS: 81 | MOUNTING SUPPLIES: 81 | REPLACEMENT PARTS: 81
ENERGY SAVING DEVICES
HALF-LIGHT® BALLAST CONTROLLERS: 84 | CLOSET LIGHT CONTROLLERS: 85
REFERENCES & INDEX
HOUSING GUIDE: 86 | INDEX: 91
(800) 888-5538 | www.functionaldevices.com

2 33 45 49 55 61 67 71 75 79 83 86
1

ENERGY SAVING

FEATURED PRODUCTS

GET BACK TO THE BASICS

2

Functional Devices, Inc. | American Made. American Owned.

FEATURED PRODUCTS

RELAYS
· Prepackaged: LED indicator, pre-wired, transient protection, and optional HOA switch · 10-30 Amp contact ratings · Coil voltages of 10-30 Vac/dc, 24 Vac/dc, 120 Vac, 208-277 Vac, 347 Vac or 480 Vac · Dry contact input relays do not need a transformer and operate on a dry contact closure · Low-input/optoisolated relays require less power from the controller · Mechanically latching and polarized/alarm relays · Red & NEMA 4 housings available
CURRENT SENSORS
· Sense currents as low as 0.125 Amp or as high as 150 Amps · Prepackaged: Sensor, LED indicators, and wires or terminals · Fixed and adjustable models · Relay/current sensor combinations available · Current transducers with 0-5 V, 0-10 V, or 4-20 mA output · Mini current switches as small as 1.5" x 2" · Self-calibrating models available

AC POWER SUPPLIES

· AC power supplies: 40 VA-500 VA · Single and dual transformer models · 500 VA, 300 VA, and 200 VA Class 2 power supplies (Five or three isolated, 24 Vac outputs) · LED indicator with circuit breaker / switch on each transformer available on some models · 120 Vac convenience outlets available, with or without primary 10 Amp circuit breaker · UL508 models available · High/Low voltage separation available · Prepackaged enclosure, power supply, and sub-panel kits

DC POWER SUPPLIES

· 300 mA, 1 Amp, or 2.5 Amp output · Adjustable output available · Class 2 models available

· 120 Vac or 24 Vac input · Isolated and non-isolated · Enclosed or track mount

(800) 888-5538 | www.functionaldevices.com

3

FEATURED PRODUCTS

10 AMP PILOT CONTROL RELAYS

RIBU1C
Enclosed Relay 10 Amp SPDT with
10-30 Vac/dc/120 Vac Coil

RIBH1C
Enclosed Relay 10 Amp SPDT with
10-30 Vac/dc/208-277 Vac Coil

Wht/Blk

Blu

120 Vac

N/C

Wht/Blu

Yel

10-30 Vac/dc

C

Wht/Yel

Org

Comm

N/O

Wht/Brn

Blu

208-277 Vac

N/C

Wht/Blu

Yel

10-30 Vac/dc

C

Wht/Yel

Org

Comm

N/O

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 1.70 x 2.80 x 1.50 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No

Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C)

RIBU1C-RD RIBH1C-RD · Red housing
RIBU1C-N4 RIBH1C-N4 · NEMA 4X housing, UL508 only
Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBU1C) 39 mA @ 208-277 Vac (RIBH1C)
Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBU1C) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBH1C) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc

10 AMP PILOT CONTROL RELAYS

RIBU1S
Enclosed Relay 10 Amp SPST-N/O + Override with
10-30 Vac/dc/120 Vac Coil

RIBH1S
Enclosed Relay 10 Amp SPST-N/O + Override with
10-30 Vac/dc/208-277 Vac Coil

Wht/Blk 120 Vac
Wht/Blu 10-30 Vac/dc
Wht/Yel Comm

CLOSED OPEN AUTO Org Org

Wht/Brn 208-277 Vac
Wht/Blu 10-30 Vac/dc
Wht/Yel Comm

CLOSED OPEN AUTO Org Org

SPECIFICATIONS
# Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.30 x 3.20 x 1.80 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: Yes

Contact Ratings: 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C)
Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBU1S) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBH1S) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc

Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBU1S) 39 mA @ 208-277 Vac (RIBH1S)
Notes: · Order Normally Closed by adding "-NC" to end
of model number

4

Functional Devices, Inc. | American Made. American Owned.

FEATURED PRODUCTS

10 AMP PILOT CONTROL RELAYS
RIB2421C
Enclosed Relay 10 Amp SPDT with 24 Vac/dc/120-277 Vac Coil

Wht/Brn

Blu

120-277 Vac

N/C

Wht/Blu

Yel

24 Vac/dc

C

Wht/Yel

Org

Comm

N/O

RIB2421C-RD · Red housing
RIB2421C-N4 · NEMA 4X housing, UL508 only
GREAT SERVICE TRUCK RELAY
ONE RELAY COVERS MOST APPLICATIONS

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 1.70 x 2.80 x 1.50 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No

Contact Ratings: 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac C300 Pilot Duty

Coil Current: 66 mA @ 24 Vac 38 mA @ 24 Vdc 40 mA @ 120-277 Vac

Coil Voltage Input: 24 Vac/dc ; 120-277 Vac ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc

20 AMP POWER CONTROL RELAYS

RIB2421B
Enclosed Relay 20 Amp with
24 Vac/dc/208-277 Vac/120 Vac Coil

RIB2421SB
Enclosed Relay 20 Amp + Override with
24 Vac/dc/208-277 Vac/120 Vac Coil

Wht/Brn

Blu

208-277 Vac

N/C

Wht/Blk 120 Vac
Yel C Wht/Blu 24 Vac/dc

Wht/Yel

Org

Comm

N/O

Wht/Brn 208-277 Vac
Wht/Blk 120 Vac
Wht/Blu 24 Vac/dc
Wht/Yel Comm

CLOSED OPEN AUTO
Org Org

RIB2421B

RIB2421SB

GREAT SERVICE TRUCK RELAY
ONE RELAY COVERS MOST APPLICATIONS

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil (RIB2421B) One (1) SPST Continuous Duty Coil (RIB2421SB)
Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F
Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.30 x 3.20 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS
Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No
Override Switch: No (RIB2421B) Yes (RIB2421SB)

Contact Ratings (RIB2421B): 20 Amp Resistive @ 277 Vac 5 Amp Resistive @ 480 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac

Coil Current: 83 mA @ 24 Vac 47 mA @ 120 Vac 69 mA @ 208-277 Vac 47 mA @ 30 Vdc

Coil Voltage Input: 24 Vac/dc ; 208-277 Vac ; 120 Vac ; 50-60 Hz Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc

Contact Ratings (RIB2421SB): 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac
Notes: · Order Normally Closed by adding "-NC" to end of model number (RIB2421SB)

(800) 888-5538 | www.functionaldevices.com

5

FEATURED PRODUCTS

AC CURRENT SWITCHES
RIBXK Series
Enclosed Self-Powered Solid Core AC Sensors
1.46"

.500" Diameter
Wire Clamp Threshold Adjust

Sensor Contact

1.863" 2.050"

LED 1 LED 2 (if present)

Removable Mounting Tab

1.008"

1.508"

RIBXKA
Wire Being Monitored Wht/ Yel
Wht/ Yel

RIBXKTF
Wire Being Monitored

SPECIFICATIONS

FUNCTIONAL DEVICES CERTIFIED FOR USE WITH ECMS

Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing)
Max Sense Voltage: 600 Vac Approvals: UL Listed, UL916, UL864, C-UL, California State Fire Marshal, CE, RoHS
Mounting/Installation: Removable mounting tab provided. The wire clamp locks against the wire being monitored, securing the unit in place.
Sensor Contact Output: Current below threshold: Open ; Current above threshold: Closed

Sensor Contact: · Solid State Contact · When sensor contact is off (open), leakage <30 uA @ 30Vac/dc · When sensor contact is on (closed), voltage drop < .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp

RIBXK SERIES

MODEL # RIBXKF

SENSING

RANGE

·

.25-150 A

RIBXKTF

·

.25-150 A

RIBXKA

·

.50-150 A

RIBXKTA

·

.50-150 A

Product Selection Guide. For full product information, see our website.

TYPE THRESHOLD SENSOR CONTACT TYPE

Solid Fixed, .25 Amp

Solid State Switch SPST

SWITCHING VOLTAGE RANGE
30 Vac/dc

MAX. SWITCHING CURRENT
.4 Amps Max

SENSOR CONTACT TERMINATION
Wht/Yel 16 18 AWG Wire Leads

Solid Fixed, .25 Amp

Solid State Switch SPST

30 Vac/dc

.4 Amps Max

Terminal Strip, Accepts #14-22 AWG Wire

Solid

Adjustable

Solid State Switch SPST

30 Vac/dc

.8 Amps Max

Wht/Yel 16 18 AWG Wire Leads

Solid

Adjustable

Solid State Switch SPST

30 Vac/dc

.8 Amps Max

Terminal Strip, Accepts #14-22 AWG Wire

= UL Listed : UL916 Energy Management, UL864 Fire ; USA & Canada

AC TRANSDUCERS
RIBXKTV Series
Enclosed Self-Powered Solid Core Current to DC Transducers
1.460"

.500" Diameter

1.863" 2.050"

1.008"

+

2.050"

­

Wire Clamp
Output: Terminal Strip Accepts 14-22 AWG wire

Removable Mounting Tab

SPECIFICATIONS

Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Accuracy: 96.8% Full Scale Loading: RIBXKTV5-10, 1% Error @ 180 k RIBXKTV5-20, 1% Error @ 90 k RIBXKTV5-50, 1% Error @ 40 k RIBXKTV5-100, 1% Error @ 15 k

RIBXKTV SERIES

MODEL #

SENSING RANGE

TYPE

RIBXKTV5-10

·

0-10 A

Solid

RIBXKTV5-20

·

0-20 A

Solid

RIBXKTV5-50

·

0-50 A

Solid

RIBXKTV5-100

·

0-100 A

Solid

= UL Listed : UL916 Energy Management, UL864 Fire ; USA & Canada

Max Sense Voltage: 600 Vac Approvals: UL Listed, UL916, UL864, California State Fire Marshal, C-UL, CE, RoHS
Mounting/Installation: Removable mounting tab provided. The wire clamp locks against the wire being monitored, securing the unit in place.
Sensor Type: Solid core with voltage output

Product Selection Guide. For full product information, see our website.

THRESHOLD Analog Analog Analog Analog

SENSOR CONTACT TERMINATION Terminal Strip, Accepts #14-22 AWG Wire Terminal Strip, Accepts #14-22 AWG Wire Terminal Strip, Accepts #14-22 AWG Wire Terminal Strip, Accepts #14-22 AWG Wire

SENSOR OUTPUT 0-5 Vdc 0-5 Vdc 0-5 Vdc 0-5 Vdc

6

Functional Devices, Inc. | American Made. American Owned.

FEATURED PRODUCTS

AC CURRENT SWITCHES
RIBXG Series
Enclosed Self-Powered Split Core AC Sensors Wire Clamp
2.000"

Sensor Contact

.52" x .52" ­ Opening for Wire Being Monitored
2.520"

LED 2 LED 1 Threshold Adjust (if present)
2.000"

1.100" 1.750"

Removable Mounting Tab

RIBXGA

RIBXGTF

Wire Being Monitored

Wire Being Monitored

Wht/Yel Wht/Yel

SPECIFICATIONS

FUNCTIONAL DEVICES CERTIFIED FOR USE WITH ECMS

Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing)
Max Sense Voltage: 600 Vac Approvals: UL Listed, UL916, UL864, C-UL, California State Fire Marshal, CE, RoHS
Mounting/Installation: Removable mounting tab provided. The wire clamp locks against the wire being monitored, securing the unit in place.
Sensor Contact Status: Current below threshold: Open Current above threshold: Closed

Sensor Contact: · Solid State Contact · When sensor contact is off (open), leakage
<30 uA @ 30Vac/dc · When sensor contact is on (closed), voltage drop
< .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp

SELF-CALIBRATING AC SWITCHES (Models with -SCAL Suffix)

Sensor Contact
LED 1 DIP Switch

RIBXG-SCAL LED INDICATORS

LED Off

No Current

Two Winks

Current Below Range

Three Winks

Current In Range

Four Winks

Current Above Range

Continuous Winks Calibration in Progress

The SCAL unit begins the 30 second self-calibration process the first time current is applied in the operating range. The threshold is then set. Subsequent calibrations may be performed by moving SW1 to the position opposite of its current position with or without current applied (hands can be safely away from live voltage). Once current begins flowing, or if it already is, the calibration process will begin. At the end of the 30 seconds, amperage will be read and set as the threshold. SW2 in the ON position provides a 15% (+/-3%) differential. In the OFF position, it provides a 25% (+/-3%) differential. SW2 can be selected at anytime and does not affect the threshold setting. Current in-range closes the sensor contact. Current above or below range opens the sensor contact.
Example: With a current of 10 amps set as the threshold and a 15% differential, sensor contact will be closed between 8.5 amps and 11.5 amps and open outside of this range. A small amount of hysteresis is provided to prevent dithering near the differential limits.

RIBXGA-SCAL

RIBXGTA-SCAL

RIBXG SERIES

MODEL # RIBXGF

SENSING RANGE
· .35-150 A

RIBXGFL

· .75-150 A

RIBXGTF

· .35-150 A

RIBXGTFL

· .75-150 A

RIBXGA

· .75-150 A

RIBXGTA

· .75-150 A

RIBXGA-SCAL · 3-150 A

RIBXGTA-SCAL · 3-150 A

TYPE THRESHOLD Split Fixed, .35 Amp

Split Fixed, .75 Amp

Split Fixed, .35 Amp

Split Fixed, .75 Amp

Split

Adjustable

Split

Adjustable

Split Self-Calibrating

Split Self-Calibrating

= UL Listed : UL916 Energy Management, UL864 Fire ; USA & Canada

Product Selection Guide. For full product information, see our website.

SENSOR CONTACT TYPE Solid State Switch SPST

SWITCHING VOLTAGE RANGE
30 Vac/dc

MAX. SWITCHING CURRENT
.4 Amps Max

SENSOR CONTACT TERMINATION
Wht/Yel 16 18 AWG Wire Leads

Solid State Switch SPST

30 Vac/dc

.4 Amps Max

Wht/Yel 16 18 AWG Wire Leads

Solid State Switch SPST

30 Vac/dc

.4 Amps Max

Terminal Strip, Accepts #14-22 AWG Wire

Solid State Switch SPST

30 Vac/dc

.4 Amps Max

Terminal Strip, Accepts #14-22 AWG Wire

Solid State Switch SPST

30 Vac/dc

.4 Amps Max

Wht/Yel 16 18 AWG Wire Leads

Solid State Switch SPST

30 Vac/dc

.4 Amps Max

Terminal Strip, Accepts #14-22 AWG Wire

Solid State Switch SPST

30 Vac/dc

.4 Amps Max

Wht/Yel 16 18 AWG Wire Leads

Solid State Switch SPST

30 Vac/dc

.4 Amps Max

Terminal Strip, Accepts #14-22 AWG Wire

(800) 888-5538 | www.functionaldevices.com

7

FEATURED PRODUCTS

POWER SUPPLIES

AC POWER SUPPLY
PSH500AB10-LVC
Enclosed 500VA Power Supply, High/Low Voltage Separation with Five 100VA Class 2 Outputs, 120 Vac to 24 Vac with 120 Vac Receptacle

Hot Neut GND

10 Amp Breaker/Switch

4 Amp Breaker

120 Vac Neutral

120 Vac Receptacle

Chassis Ground Switch 4 Amp Breaker Switch 4 Amp Breaker Switch 4 Amp Breaker Switch 4 Amp Breaker Switch 4 Amp Breaker

LED Indicator
LED Indicator
LED Indicator
LED Indicator
LED Indicator

PSH500AB10-LVC
Shown With High Voltage Cover & Low Voltage Access Plate

SPECIFICATIONS
Transformer: One (1) 500 VA Over Current Protection: Circuit Breaker
Primary: 120 Vac Frequency: 50/60 Hz Main Breaker ON/OFF: Switch / Breaker (10 Amp)
(Kills power to entire unit: 1 Outlet & Transformer) Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS Dimensions: 12.125 x 12.125 x 6.000 Housing: NEMA1 Metal Enclosure with high/low separation

5 Secondaries: 24 Vac, with LED Indicators 4 Amp breaker for each output
24 Vac ON/OFF: On / Off Switch & Breaker
Input: 120 Vac Finger-Safe Terminals, 8-18 AWG
Output: 5 Ungrounded, Isolated, 100 VA Class 2, 24 Vac Outputs. Removable Terminals accept16-22 AWG wire.
Ambient Temperature Derating: 4A up to 40° C ; 3A up to 50° C ; 2A up to 55° C (When All 5 Outputs Operated Simultaneously)

Standby Wattage: 48.515 W @ 120 Vac
Full Load Primary Current: 4.66 A @ 120 Vac
Secondary Output Voltage vs. Load: 24.0 V @ 1 Amp 23.0 V @ 2 Amp 21.8 V @ 3 Amp 21.1 V @ 4 Amp
· When all 5 outputs operated simultaneously, at room temperature
Notes: · 4A (Breaker protected) Convenience
Receptacle Provided

8

Functional Devices, Inc. | American Made. American Owned.

FEATURED PRODUCTS

POWER SUPPLIES
Multi-tap Primary
480/277/240/120 Vac OR 480/347/277/240/120 Vac
480 277 240 120 COM
ON 1
OFF ON OFF 2 ON OFF 3 ON OFF 4 ON OFF 5
Low Voltage Compartment for safe access

LOW VOLTAGE COMPARTMENT POWER SUPPLY SERIES
Perfect for providing Class 2 low voltage to central power supply
panels and peripheral devices

PSH30C0onAtr-oLlleVr C P24SVHac500A-LVC
TCP-1

PSH30C0onAtr-oLlleVr C P24SVHac500A-LVC
TCP-2

PSH30C0onAtr-oLlleVr C P24SVHac500A-LVC
TCP-3

PSH30C0onAtr-oLlleVr C P24SVHac500A-LVC
TCP-4

PSH30C0onAtr-oLlleVr C P24SVHac500A-LVC
TCP-5

Eliminate high voltage in your control panel and the need for personal protective equipment (PPE) by using our Low Voltage Compartment Power Supplies. This series of products has a separate wiring compartment (with removable cover) to safely access the removable terminal blocks.
Product Features
· Three or five isolated 100 VA Class 2, 24 Vac outputs with 4 Amp Breaker and individual On/Off switches. Also available with five 40 VA outputs (See chart below)
· NEMA 1 metal enclosure has separate low voltage compartment with cover · Multi-tap primaries: 480/277/240/120 Vac or 480/347/277/240/120 Vac · Seismic Certification of Equipment and Components: OSP-0201-10 · UL916 & Class 2 (UL Approved UL5085-3)

LOW VOLTAGE COMPARTMENT POWER SUPPLIES

MODEL # PSH500A-LVC

TRANSFORMER(S)
· 500 VA (five 100 VA Outputs)

PSH300A-LVC · 300 VA (three 100 VA Outputs)

PSH200A-LVC · 200 VA (five 40 VA Outputs)

PSH500AB10-LVC · 500 VA (five 100 VA Outputs)

PSH300AB10-LVC · 300 VA (three 100 VA Outputs)

PSH200AB10-LVC · 200 VA (five 40 VA Outputs)

INPUT POWER
480/277/240/120 Vac 480/277/240/120 Vac 480/347/277/240/120 Vac
120 Vac 120 Vac 120 Vac

HEIGHT
12.125 12.125 12.125 12.125 12.125 12.125

WIDTH
12.125 12.125 12.125 12.125 12.125 12.125

= Class 2 (UL Approved UL5085-3) : UL916 Energy Management USA & Canada

Product Selection Guide. For full product information, see our website.

DEPTH
6.000 6.000 6.000 6.000 6.000 6.000

120 VAC BREAKER PER SECONDARY OUTLET# OUTPUT CONFIGURATION

5 x 4 Amp

Terminals

3 x 4 Amp

Terminals

5 x 2 Amp

Terminals

·

5 x 4 Amp

Terminals

·

3 x 4 Amp

Terminals

·

5 x 2 Amp

Terminals

HOUSING STYLE
Enclosed with Low Voltage Compartment
Enclosed with Low Voltage Compartment
Enclosed with Low Voltage Compartment
Enclosed with Low Voltage Compartment
Enclosed with Low Voltage Compartment
Enclosed with Low Voltage Compartment

# = Convenience outlet has 4 Amp Breaker

(800) 888-5538 | www.functionaldevices.com

9

FEATURED PRODUCTS
C NC NO NC C NO

10 AMP PILOT CONTROL RELAYS

RIBRL1C
DIN Mount Relay 10 Amp SPDT with
10-30 Vac/dc Coil

RIBRL1S
DIN Mount Relay 10 Amp SPDT + Override
10-30 Vac/dc Coil

PWR CTRL COM CLOSED OPEN AUTO
10-30V COM

Relay LED Not Used
Open Lid this Side

Override Switch
Relay LED Not Used
Open Lid this Side
Apply Continuous Power (10-30Vac/dc) to PWR and COM. Apply Coil Control (10-30Vac/dc) to CTRL and COM.

ADIN35
DIN Rail Perforated 35mm x 7.5mm x 1m

Specifications
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20mS Relay Status: LED On = Activated Dimensions: 3.88 x 2.76 x 0.78 Terminal Strip: 14-22 AWG wire Approvals: UL Listed, UL916, C-UL, CE, RoHS Gold Flash: Yes
Replacement Relay: ARL1C Accessories: ADIN35, ADIN35ES

Models ADIN35 and ADIN35ES sold separately. See data sheet on website for more product information.

ADIN35ES Pair of End Stops for 35mm DIN Rail

Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240/277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C)

Coil Current: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac

13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc

Power and Control Voltage: 10-30 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc

10 AMP PILOT CONTROL RELAYS

RIBR24D
DIN Mount Relay 10 Amp DPDT with
24 Vac/dc Coil

RIBR24SD
DIN Mount Relay 10 Amp DPDT + Override
24 Vac/dc Coil

CLOSED

OPEN

AUTO

24Vac/dc COM NC1 NC2

NO2 NO1 C2 C1 NO2 NO1 C2 C1

Relay LED Not Used
Open Lid this Side

NC1 NC2

PWR CTRL COM

Override Switch
Relay LED Not Used
Open Lid this Side
Apply Continuous Power (24Vac/dc) to PWR and COM.
Apply Coil Control (24Vac/dc) to CTRL and COM.

ADIN35
DIN Rail Perforated 35mm x 7.5mm x 1m

Specifications
# Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 8mS Relay Status: LED On = Activated Dimensions: 3.88 x 2.76 x 0.78 Terminal Strip: 14-22 AWG wire Approvals: UL Listed, UL916, C-UL, CE, RoHS
Replacement Relay: AR24D Accessories: ADIN35, ADIN35ES

Models ADIN35 and ADIN35ES sold separately. See data sheet on website for more product information.

ADIN35ES Pair of End Stops for 35mm DIN Rail

Contact Ratings: 10 Amp Resistive @ 30 Vdc 10 Amp General Use @ 277 Vac 1/2 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/C) B300 Pilot Duty  120Vac 30A Make 3A Break (360 VA)  240Vac 15A Make 1.5A Break (360 VA)  208Vac 17.3A Make 1.73A Break (360 VA)  277Vac 13A Make 1.3A Break (360 VA)  24Vac 30A Make 5A Break (120VA) 5A Max

Power and Control Current: 24 mA @ 18 Vac 20 mA @ 20 Vdc 32 mA @ 24 Vac 24 mA @ 24 Vdc 40 mA @ 30 Vac 36 mA @ 24 Vdc
Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 18 Vac / 20 Vdc

10

Functional Devices, Inc. | American Made. American Owned.

FEATURED PRODUCTS

RELAYS
DIN RAIL MOUNT
RELAY IN A BOX®

Product Features · Removable socket relay · Prepackaged for easy installation · 10 Amp contact rating   · 10-30 Vac/dc or 24 Vac/dc coil voltage · Models available with override switch · Current sensor models available · UL916 Listed and Made in the USA
Benefits · Suitable for a wide variety of applications · Multi-coil voltages eliminate need to stock
multiple equivalent relays

DIN RAIL MOUNT RELAYS

MODEL #

COIL VOLTAGE AC/DC

RELAY CONTACTS

RIBRL1C

· 1

10-30

1 SPDT

RIBRL1S

· 1

10-30

1 SPDT

RIBR24D

· 1

24

1 DPDT

RIBR24SD

· 1

24

1 DPDT

RESISTIVE 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac

Product Selection Guide. For full product information, see our website.

CONTACT RATINGS MOTOR

PILOT DUTY

OVERRIDE SWITCH

TRACK MOUNT ^

1/3 HP @ 120-240 Vac (N/O) 480 VA @ 240/277 Vac

DIN Rail

1/3 HP @ 120-240 Vac (N/O) 480 VA @ 240/277 Vac

1 #

DIN Rail

1/2 HP @ 120-240 Vac (N/O)

B300

DIN Rail

1/2 HP @ 120-240 Vac (N/O)

B300

1 #

DIN Rail

DIN Rail (ADIN35) and pair of end stops (ADIN35ES) sold separately.

1 = UL Listed : UL916 Energy Management ; USA & Canada

# = Coil side relay override (requires unit to be powered)

^ = Track mount sold separately

(800) 888-5538 | www.functionaldevices.com

11

FEATURED PRODUCTS

NETWORK COMPATIBLE DEVICES

DEVICES APPLICATIONS
See the diagrams below for examples of common uses.

RIBTW2401B-BC, RIBTW2402B-BC

MS/TP

DO

Pump or Fan Start/Stop

DI

Status

RIBMNWX2401B-BC, RIBTWX2401B-BC, RIBMNWX2402B-BC, RIBTWX2402B-BC

MS/TP

DO

Pump or Fan Start/Stop

DI

Status, Flow Switch

INTERNAL CURRENT SENSOR

RIBMNW24B-BCAI, RIBTW24B-BCAI

MS/TP

DO DI (2) AI

RIBTW24B-BCAO

DO

MS/TP

DI

AI

AO

RIBMNWD12-BCDI

Exhaust Fan Start/Stop Status Room Temperature
Pump or Fan Start/Stop Status, Flow Switch Water Temperature Valve Position

MS/TP RIBMNWD12-BC MS/TP RIBMW24B-44-BC MS/TP

DI (12)

Fan Wall Status or Kitchen Hood Status

DI (10) ACM (2)

Pump Status Pulse Meter

DO (4) DI (4)

Pump or Fan Start/Stop Status

12

Functional Devices, Inc. | American Made. American Owned.

FEATURED PRODUCTS

NETWORK COMPATIBLE DEVICES

PREPACKAGED

DEVICES

MAKE THE JOB EASY.

Use when a few more control points are needed and a multi-output controller is too much for the job.

RIBTWX2402B-BC

RIBTW2401B-BC

RIBMNW24B-BCAI

PSH600-UPS-BC
Features
· MS/TP network · One binary output (20 Amp) · One binary input (dry contact) · Field addressable · DIP switch selectable baud rate · Power inputs: 24 Vac/dc or 120 / 208-277 Vac · Enclosed or track mount models · UL Listed · BTL Certified · Made in the USA

Several Devices with Varying Options
· Relays · Relay & current sensor combinations · Expansion module · Analog input · Analog output · Thermistor input · Accumulator input · 600 VA UPS power supply kit · Fan safety alarm circuit / general purpose logic board

(800) 888-5538 | www.functionaldevices.com

13

FEATURED PRODUCTS
REF B(+) A(­)

NETWORK COMPATIBLE DEVICES

RIBMNW24B-BCAI
2.75" Track Mount BACnet® MS/TP Network Relay Device with Binary Output Set Point Function; One Binary Output (20 Amp Relay SPDT + Override); Two Binary Inputs (Dry Contact, Class 2); One Analog Input (T2/T3 Thermistor / 0-5 Vdc / 0-10 Vdc); 24 Vac/dc Power Input; Optional End of Line Resistor (EOL) Included.

RIBTW24B-BCAI
Enclosed BACnet® MS/TP Network Relay Device with Binary Output Set Point Function; One Binary Output (20 Amp Relay SPDT + Override); Two Binary Inputs (Dry Contact, Class 2); One Analog Input (T2/T3 Thermistor / 0-5 Vdc / 0-10 Vdc); 24 Vac/dc Power Input; Optional End of Line Resistor (EOL) Included.

Green LED - Network Status Red LED - Relay Status Pink LED - B1 1 Status Pink LED - B1 2 Status BI 1 COM BI 1 BI 2 COM BI 2

5V 10 V 1 2

MS/TP ^See EOL Resistor jumper
1 0

^To select AI

OPEN
AI Voltage Select ^# Switch

for Thermistor T2 or T3 input. Install jumper

Connect Jumper for EOL.

Disconnect for no

terminating resistor

1 2 3 4 5 6 7 8 9 10 11 12

RELAY CONTROL

BAUD RATE

LSB MS/TP ADDRESS
MSB

Analog Type Jumpers OFF OFF Not de ned OFF ON T2 Thermistor ON OFF T3 Thermistor ON ON Analog IN 5V or 10V

AI A1 COM Therm. +5V

Analog In Close only one)

5V SW1 Closed SW2 Open

10V

SW1 Open SW2 Closed

Thermistor T2 or T3 input, use 5V
selection

Relay Contacts

24 Vac/dv}
Comm N/C

N/O

C

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms
Network Communication: Green LED Relay Status: Red LED On = Activated BI1 Status: Pink LED On = Activated BI2 Status: Pink LED On = Activated Dimensions: 6.25 x 2.75 x 1.75 (RIBMNW24B-BCAI) 4.28 x 7.00 x 2.00 with .75 NPT Nipple (RIBTW24B-BCAI) Track Mount: MT212-6 Mounting Track Provided Approvals: UL Listed, UL916, C-UL, CE, RoHS
Housing Rating: UL Listed, NEMA 1, C-UL, CE Approved, UL Accepted for Use in Plenum, Also available NEMA 4 / 4X
Gold Flash: No Relay Override Switch: DIP Switch Control (See Bulletin B1243)

Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac
Power Input Ratings: 81 mA @ 24 Vdc 111 mA @ 24 Vac
· PIC Statement available on website. http://www.functionaldevices.com/ downloads/pics/BACnet-BCAI_PICS.pdf

Network Media: Twisted Pair 22-24AWG, shielded recommended
Terminations: Functional Devices product installed at both ends of the MS/TP network ­ Use 120  end of line resistors. All other cases ­ Follow instructions from the device installed at the end of the MS/TP network.
Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200
(DIP Switch Selectable - See Bulletin B1243)

Set Point Function
for App. Version 1.5 or higher
BCAI

Sensor 0-5Vdc, 0-10Vdc or T2/T3 Thermistor

BI1 BI2 AI1 Logic

BO1
Set Point Differential

Network

Code Version 1.5
Notes: · Order NEMA 4 housing by adding "-N4" to end of model number. (RIBTW24B-BCAI-N4) · Order with grey lid by adding "-GY" to end of model number. (RIBTW24B-BCAI-GY) · Order NEMA 4 housing with grey lid by adding "-N4-GY" to end of model number. (RIBTW24B-BCAI-N4-GY) · For all versions, raw analog default settings are 0 and 1023 (real), respectively. Units default to 95 (no units).
For Set Point Functiona settings, See Bulletin B1243 · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, (See Bulletin B1243 for diagram)
BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples:
MS/TP Address - 004 MS/TP Address - 121 Device ID - 277004 Device ID - 277121
· Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.) · This model utilizes: BO 1 (Relay output), BI 1 (Dry contact binary input), BI 2 (Dry contact binary input), AI 1 (Analog input), AV1 (Set Point), AV2 (Differential), BV1 (Function Enable), BV2 (Function Mode), BV3 (Function Status) · Device Instance changed via Object Identifier Property of Device Object
Thermistor Specifications: · Thermistor Type 2 (T2) Precon 10 K @ 77°F (25°C) PN ST-R24, Model 24, (or equivalent.) Thermistor Type 3 (T3) Precon 10 K @ 77°F (25°C) Model 3, (or equivalent.) Thermistor not included.
· For both T2 and T3, MIN_PRES_VAL must be set to -36 (real value) and MAX_PRES_VAL must be set to 66.3 (real value) for Celcius. For Fahrenheit, MIN_PRES_VAL must be set to -32.8 (real value) and MAX_PRES_VAL must be set to 151.34 (real value). · -35 to 10°C range in 1° steps / -31 to 50°F range in 1.8° steps 10 to 32°C range in 0.1° steps / 50 to 90°F range in 0.18° steps 32 to 100°C range in 1° steps / 90 to 212°F range in 1.8° steps

Set Point Function must be enabled via the Network for logic to execute. Once configured, the function will continue to operate
even if communication is lost (see Bulletin B1243 for setup).

14

Functional Devices, Inc. | American Made. American Owned.

FEATURED PRODUCTS

NETWORK COMPATIBLE DEVICES

LOCAL LOGIC

NETWORK DEVICE

WITH SET POINT FUNCTION FOR BINARY OUTPUT

RIBTW24B-BCAI
shown without cover
RIBMNW24B-BCAI

Features
· BACnet® MS/TP network · One binary output: 20 Amp SPDT + override · Two binary inputs: Dry contact · One analog input: Thermistor T2 or T3, 0-5Vdc, 0-10Vdc
· 24 Vac/dc power · NEMA 1 enclosure, available in NEMA 4 enclosure · UL Listed · Made in the USA

Designed for Remote/Local Applications
Cabinet unit heater, cooler/freezer, exhaust fan, fluid level - sump pump, building pressure, etc.

Cabinet Unit Heater
Temperature AHU
Transformer

BACnet MS/TP

BCAI

Set Point Differential

Logic

BI 1

Dry Contact Input 1

BI 2

Dry Contact Input 2

AI 1

Analog Input

0-5Vdc, 0-10Vdc

T2/T3 Thermistor

BO 1

SPDT 20 Amp Relay

With Override

Building Pressure

Building Pressure

Damper

Fluid Level - Sump Pump

Hi

Low

AHU

Transformer

BCAI

Transformer

BCAI

Valve

RIBU1C

Cooler/Freezer
Temperature

Transformer

BCAI

Walkin Freezer/Cooler
Door Switch

Audible alarm or alarm lamp
Exhaust Fan
Temperature
AHU

Transformer

BCAI

(800) 888-5538 | www.functionaldevices.com

15

FEATURED PRODUCTS
Line Neut. Gnd. Gnd. Neut. Line Red LED = Device Power Pink LED = Device Status Green LED = Network Comm.

UNINTERRUPTIBLE POWER SUPPLY KIT - BACNET® COMPATIBLE

PSH600-UPS-BC
Enclosed BACnet® Network 600 VA UPS Backup Power Control Center

UPS

UPS Output to protected
device Line Input
RESET
OFF
1 2 3 4 5 6 7 8 9 10 OPEN

EOL Jumper
Yellow LED = Backup Power
Blue LED = USB Status

B(+) A(-) BACnet® REF comm.
USB Jack

}

UPS plugged into one of two outlets. Other outlet spare.

Shown Without Cover

To UPS
SPECIFICATIONS

BOARD AND ENCLOSURE:
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Indicators: Device Power: Red LED Device Status: Pink LED Network Communication: Green LED Backup Power: Yellow LED USB Status: Blue LED
Main Breaker ON/OFF: Switch / Breaker (10 Amp) Dimensions: 12" x 16 x 6 Track Mount: 2.750 x 8.000 MT212-8N Mounting Track Included Approvals: UL Listed, UL916, C-UL, CE, RoHS Line Input: 120Vac, 10A(max)
Convenience Receptacles: 120Vac, 10A(max combined)
Information provided over BACnet® network can be used to schedule
"predictive maintenance" such as UPS battery replacement, etc.

Power Input Rating: 25mA @ 120Vac Network Media: Twisted Pair 22-24 AWG, shielded recommended (MS/TP) USB A/B (device to UPS, included) Terminations: Functional Devices product installed at both ends of the MS/TP network - Use 120 Ohm End of Line Resistors. All other cases follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive. Baud Rate: 9600, 192000, 38400, 76800, 115200 ( DIP Switch Selectable)

Notes: · Circuit breaker for short-circuit protection. · 14/3 Line Cord included (3´).
BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples:
MS/TP Address - 004 Device ID - 277004
MS/TP Address - 121 Device ID - 277121

DIP SWITCHES*

8

9

10

0

0

0

0

0

1

0

1

0

0

1

1

1

0

0

BAUD RATE
9600 19200 38400 57600 76800

· Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.) · Devices Instance changed via Object Identifier Property of Device Object. · Status of UPS connection, Battery run time, line power ,UPS load (VA and %), and battery capacity can be read from BACnet network.

1

0

1

115200

UPS:
UPS: 600VA Backup Time: 2.5 Min. @ Full 600 VA Load
10.2 Min. @ 1/2 Load Input: 120 Vac, 12 Amp Output: 120 Vac, 4.6 Amp Max Load: 330 Watt Frequency: 50/60 Hz Temperature Rating of UPS: 32 to 104° F UPS Transfer Time: 6ms Approvals: UL Listed, UL1778

* 0 = Open ; 1 = Closed All other combinations = 9600 baud
Notes: · Average battery life: 3-5 years depending on the number of discharge cycles and environmental temperature · This model is not designed to notify user of battery failure. · This model is designed to work exclusively with Functional Devices Model UPS600 · UPS may change based on quality and availability.

ESTIMATED BACKUP TIME VS. LOAD
60 50 40
30 20

Backup Time (Minutes)

10

0

0

50 100 150 200 250 300 350

Load (Watts)

16

Functional Devices, Inc. | American Made. American Owned.

FEATURED PRODUCTS

NETWORK COMPATIBLE DEVICES
COMPATIBLE 600VA UPS POWER SUPPLY
Provides power to your critical controller in hospitals, laboratories, and research centers in the event of a power outage.
600VA Commercial UPS NEMA 1 Enclosure BACnet® Compatible Interface Board

Features

PSH600-UPS-BC

· Hardwire line voltage to UPS

· Hardwire UPS to final load

· Clean & neat use of a UPS, keeping

 equipment and cords tucked inside

 the enclosure

· Extra 120 Vac outlet & 10 Amp circuit

breaker on/off switch for testing

functionality of UPS

Objects
· Line or UPS power, UPS percent load,
 UPS battery capacity, VA load, USB  connection, and remaining battery time

(800) 888-5538 | www.functionaldevices.com

17

FEATURED PRODUCTS

AC TRANSDUCER
RIBXGTV5
Enclosed Self-Powered Spilt Core Multi-Range (0-20A, 50A, or 100A) AC Transducer with 0-5Vdc Terminal Output
Wire Clamp

2.000"
.52" x .52" Opening for Wire Being Monitored
2.520"
1.100" 1.750"

2.000"

Output: Terminal Strip
Accepts 14-22 AWG wire

Removable Mounting Tab
SPECIFICATIONS
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Accuracy: 98.3% Full Scale Loading: RIBXGTV5, (0-20 Amp), 5% Error @ 58 k RIBXGTV5, (0-50 Amp), 5% Error @ 31.3 k RIBXGTV5, (0-100 Amp), 5% Error @ 12.3 k

Max Sense Voltage: 600 Vac Approvals: UL Listed, UL916, UL864, California State Fire Marshal, C-UL, CE, RoHS
Mounting/Installation: Removable mounting tab provided. The wire clamp locks against the wire being monitored, securing the unit in place.
Sensor Type: Split core with voltage output

DIP SWITCH

1

2 Sensing Range

OFF OFF

0-20 Amp

OFF ON

0-50 Amp

ON OFF

0-100 Amp

AC TRANSDUCER
RIBXGTV10
Enclosed Self-Powered Spilt Core Multi-Range (0-20A, 50A, or 100A) AC Transducer with 0-10Vdc Terminal Output
Wire Clamp

2.000"
.52" x .52" Opening for Wire Being Monitored
2.520"
1.100" 1.750"

2.000"

Output: Terminal Strip
Accepts 14-22 AWG wire

Removable Mounting Tab
SPECIFICATIONS
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Accuracy: 98.8% Full Scale Loading: RIBXGTV10, (0-20 Amp), 5% Error @ 60.4 k RIBXGTV10, (0-50 Amp), 5% Error @ 25.24 k RIBXGTV10, (0-100 Amp), 5% Error @ 13.65 k

Max Sense Voltage: 600 Vac Approvals: UL Listed, UL916, UL864, California State Fire Marshal, C-UL, CE, RoHS
Mounting/Installation: Removable mounting tab provided. The wire clamp locks against the wire being monitored, securing the unit in place.
Sensor Type: Split core with voltage output

DIP SWITCH

1

2 Sensing Range

OFF OFF OFF ON ON OFF

0-20 Amp 0-50 Amp 0-100 Amp

18

Functional Devices, Inc. | American Made. American Owned.

FEATURED PRODUCTS

CURRENT TRANSDUCERS
USE OUR MULTI-RANGE SPLIT CORE CURRENT TRANSDUCERS TO CALCULATE ENERGY USAGE USING AMPERAGE FEEDBACK.
0-5 Vdc or 0-10 Vdc terminal output DIP switch selectable sensing ranges
Small Size
· 2.00" x 2.52" x 1.10" · Easily fits inside an enclosure with room to spare · Includes foot mounting insert
Unique Core Opening
· Slide opening (vs. hinged opening) · One inch of extra space allows for core to fully extend · Monitor wires up to a half-inch in diameter
Ratcheting Wire Clamp
· Ratcheting clamp tightens around wire · Clamp sensors on wires where foot mounting is not ideal

Slide opening helps with installation in small spaces

Ratcheting clamp tightens around wire

Foot mounting insert included

CURRENT TRANSDUCERS

MODEL # RIBXGTV5

SENSING RANGE

TYPE

·

0-20 A, 0-50 A, 0-100 A

Split

RIBXGTV10

·

0-20 A, 0-50 A, 0-100 A

Split

= UL Listed : UL916 Energy Management, UL864 Fire ; USA & Canada

Product Selection Guide. For full product information, see our website.

THRESHOLD

SENSOR CONTACT TERMINATION

SENSOR OUTPUT

Analog

Terminal Strip, Accepts #14-22 AWG Wire

0-5 Vdc

Analog

Terminal Strip, Accepts #14-22 AWG Wire

0-10 Vdc

(800) 888-5538 | www.functionaldevices.com

19

FEATURED PRODUCTS

RELAY & AC CURRENT SWITCH COMBOS
RIBHX24BF
Enclosed 20 Amp SPST-N/O Relay/AC Fixed Current Sensor Combination, with 24 Vac Coil
Gry
Sensor Feedback Current Sensor Status
Gry

Wht/Yel 24 Vac Wht/Yel

Org - C Org - N/O

RIBHX24BF-RD · Red housing
RIBHX24BF-N4 · NEMA 4X housing, UL508 only

SPECIFICATIONS

FUNCTIONAL DEVICES CERTIFIED FOR USE WITH ECMS

Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F
Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: Red LED On = Activated
Current Sensor Status: Pink LED On = Current Over Trip Point (0.25 Amp)
Dimensions: 1.70 x 2.80 x 1.50 with .50 NPT nipple Wire Length: 16, 600V Rated
Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1
Gold Flash: No
Sensor Type: Internal, with contact status Sensor Threshold: Fixed, .25 Amp
Sensor Range: .25-20 Amps Sensor Feedback Output: Solid State Contact 30 Vac/dc, 100 mA

Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1,110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac

Sensor Contact: · When current sensor status is off (open), leakage <30 uA @ 30Vac/dc · When current sensor status is on (closed), voltage drop < .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp

Coil Current: 128 mA @ 24 Vac 71 mA @ 30 Vdc

Coil Voltage Input: 24 Vac ; 50-60 Hz Drop Out = 3 Vac Pull In = 18 Vac

RELAY & AC CURRENT SWITCH COMBOS

RIBHX24BA
Enclosed 20 Amp SPST-N/O Relay/AC Adjustable
Current Sensor combination, with 24 Vac/dc coil

RIBHX24BA-RD · Red housing

Gry
Sensor Feedback Current Sensor Status
Gry

Wht/Yel 24 Vac Wht/Yel

Org - C Org - N/O

SPECIFICATIONS

FUNCTIONAL DEVICES CERTIFIED FOR USE WITH ECMS

Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F
Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: Red or Green LED On = Activated
Current Sensor Status: Green LED On = Current Over Trip Point Adjustable
Dimensions: 1.70 x 2.80 x 1.50 with .50 NPT nipple Wire Length: 16, 600V Rated
Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1
Gold Flash: No
Sensor Type: Internal, with contact status Sensor Threshold: Adjustable, .25 Amp
Sensor Range: .25-20 Amps Sensor Feedback Output: Solid State Contact 30 Vac/dc, 100 mA
Hysteresis Solid

Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1,110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac

Sensor Contact: · When current sensor status is off (open), leakage <30 uA @ 30Vac/dc · When current sensor status is on (closed), voltage drop < .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp

Coil Current: 128 mA @ 24 Vac 71 mA @ 30 Vdc

Coil Voltage Input: 24 Vac ; 50-60 Hz Drop Out = 3 Vac Pull In = 18 Vac

20

Functional Devices, Inc. | American Made. American Owned.

FEATURED PRODUCTS

COMBINATIONS
RELAY & CURRENT SENSOR COMBINATIONS
MOUNT OUTSIDE YOUR ENCLOSURES

ADJUSTABLE THRESHOLD

FIXED THRESHOLD

· Prepackaged with a 20 Amp relay and internal current sensor
· NEMA 1 enclosure approved for plenum spaces · Nipple mount allows for installation outside
of your enclosures · Adjustable or fixed threshold · LEDs indicate coil activation & when current
is over trip point · UL Listed · Made in the USA

(800) 888-5538 | www.functionaldevices.com

21

FEATURED PRODUCTS

AC POWER SUPPLY KITS
MHP4604100AB10
Enclosed Single 100 VA Power Supply with Subpanel: Models MH4600 + SP4604 + PS100AB10

MHP4604100A100AB10
Enclosed Dual 100 VA Power Supply with Subpanel:
Models MH4600 + SP4604 + PS100A100AB10

14.25"

1414..8877" " 1313..0000" "

5.15" 5.438" 5.150"

4.50" 4.500"

4.50" 4.25"

ON 4.500"

RESET

OFF

4.250"

OFF

5.15" 5.150"

Class 2

20.00"
114.4.626"2" 112.2.878"7"

17.50"

6.72"

16.15"

8.625"
88..22505" "

ON

ON

OFF

OFF

RESET

OFF

88.2.2550""

44..5050"0" 44..2520"5"

44..55000" "

MHP4604100AB10

MHP4604100A100AB10

POWER SUPPLY (PS100AB10)
Transformer: One 100 VA Split-Bobbin Over Current Protection: Circuit Breaker
Frequency: 50/60 Hz 24 Vac ON/OFF: On / Off Switch & Breaker Main Breaker ON/OFF: Switch / Breaker (10 Amp)
(Kills power to entire unit: Outlets, Aux. Output, & Transformer)* Total Combined Output 9A Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS Dimensions: 4.500 x 8.625 x 4.500

Input Wires: Input Power Wires BLK: 120 Vac WHT: Neutral GRN: Ground
Outlet Wires BLK: 120 Vac WHT: Neutral GRN: Ground
Output Wires: Auxiliary Output BLU: 120 Vac

Notes: · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time. · Design is in accordance with ASCE 7-05 Chapter 13

POWER SUPPLY (PS100A100AB10)
Transformer: Two 100 VA Split-Bobbin Over Current Protection: Circuit Breaker
Frequency: 50/60 Hz 24 Vac ON/OFF: On / Off Switch & Breaker Main Breaker ON/OFF: Switch / Breaker (10 Amp)
(Kills power to entire unit: Outlets, Aux. Output, & Transformer)* Total Combined Output 9A Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS Dimensions: 4.500 x 8.625 x 4.500

Input Wires: Input Power Wires BLK: 120 Vac WHT: Neutral GRN: Ground
Outlet Wires BLK: 120 Vac WHT: Neutral GRN: Ground
Output Wires: Auxiliary Output BLU: 120 Vac

Notes: · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time. · Design is in accordance with ASCE 7-05 Chapter 13

PERFORATED STEEL SUB-PANEL (SP4604)
Mounting Area: 217.40 square Approvals: Plenum Rated
Dimensions: 14.62" x 14.87"

METAL HOUSING (MH4600)
Construction: 14 Gauge Steel Cover Type: Reversible Hook Hinge Key Latch Door Approvals: UL Listed, C-UL, CE Approved, RoHS Dimensions: 16.15" (W) x 20.00" (H) x 6.72" (D)

22

Functional Devices, Inc. | American Made. American Owned.

FEATURED PRODUCTS

POWER SUPPLIES

MOUNTING YOUR CONTROLLER AND PERIPHERAL DEVICES IS EASY AND CONVENIENT IN OUR PREPACKAGED SOLUTION

Metal enclosure, power supply, and sub-panel with several options to fit your needs

If you're planning to install a controller and other peripheral devices, it is important to consider where the items will be placed within an enclosure and how they will be powered. We have a line of products that can address both of those needs: the MHP Series. These products include a metal enclosure, power supply and a sub-panel with several prepackaged options to meet your specific needs.

WIDE ENCLOSURE ALLOWS MORE
ROOM FOR WIRE WAYS

Power Supply
· Enclosed single or dual 100 VA · 10 Amp on/off circuit breaker switch(es) · 120 Vac convenience outlets · 24 Vac output terminal strip(s) · High/low voltage separation

Wide Enclosure Single 100 VA Power Supply Perforated Steel Sub-Panel
MHP4604100AB10

Enclosure

· Two size choices

Narrow Enclosure

· Reversible door with key latch · Sturdy 14-Gauge steel

Single 100 VA Power Supply Perforated Steel Sub-Panel
MHP3904100AB10

Sub-Panel
· Perforated steel or polymetal

Narrow Enclosure Dual 100 VA Power Supply

· Easily removable for mounting equipment

Polymetal Sub-Panel

MHP3903100A100AB10

PREPACKAGED AC POWER SUPPLY KITS

Product Selection Guide. For full product information, see our website.

MODEL # MHP3903100AB10

TRANSFORMER(S)
100 VA

INPUT

120 VAC AUX OUTPUT ON/OFF MAIN BREAKER ON SECONDARY METAL

SUB-PANEL /

POWER HEIGHT WIDTH DEPTH OUTLETS WIRE SWITCH INPUT POWER * CONFIGURATION HOUSING TRACK MOUNT

120 Vac 12.500 24.500 6.500 ·

·

· 10 A Switch/Breaker Ext. Terminal Strip MH3900 SP3803S (Polymetal)

MHP3904100AB10

100 VA 120 Vac 12.500 24.500 6.500 ·

·

· 10 A Switch/Breaker Ext. Terminal Strip MH3900 SP3804S (Perforated)

MHP4604100AB10

100 VA 120 Vac 16.150 20.000 6.720 ·

·

· 10 A Switch/Breaker Ext. Terminal Strip MH4600 SP4604 (Perforated)

MHP3903100A100AB10 100 VA, 100 VA 120 Vac 12.500 24.500 6.500 ·

·

· 10 A Switch/Breaker Ext. Terminal Strip MH3900 SP3803S (Polymetal)

MHP3904100A100AB10 100 VA, 100 VA 120 Vac 12.500 24.500 6.500 ·

·

· 10 A Switch/Breaker Ext. Terminal Strip MH3900 SP3804S (Perforated)

MHP4604100A100AB10 100 VA, 100 VA 120 Vac 16.150 20.000 6.720 ·

·

· 10 A Switch/Breaker Ext. Terminal Strip MH4600 SP4604 (Perforated)

* = Kills power to entire unit: Outlets, Aux. Output, & Transformer; Total Combined Output 9A

(800) 888-5538 | www.functionaldevices.com

23

FEATURED PRODUCTS

POWER CONTROL

Models shown (L to R) without covers: PSH2C2RB10; PSM2RB10; PSH600-UPS-BC

Uninterruptible Power Supply Kits

 · 600 or 850 VA commercial UPS

 · NEMA 1 metal enclosure

 · UPS interface board

·

compatible model available

24

Functional Devices, Inc. | American Made. American Owned.

FEATURED PRODUCTS

POWER CONTROL

UPS POWER SUPPLY SERIES

Our UPS Power Supply Series is perfect for applications in critical environments such as hospitals, laboratories and research & surgery centers. These products keep your critical controller powered on during a loss of normal utility power with the ability to hardwire line voltage to the provided UPS, in addition to hardwiring the UPS to the final load.

Benefits & Features
 · Keeps your critical controller on in the case of power loss  · BACnet® compatible model is BTL Certified and includes six objects:
Line or UPS power, UPS percent load, UPS battery capacity, VA load, USB connection, and remaining battery time  · Cords tuck inside enclosure for clean & neat use of a UPS  · 600 VA UPS is hot-swappable  · 120 Vac convenience outlet(s) provided  · 10 Amp circuit breaker/switch can be used to test functionality of UPS  · Switch controls line voltage

UPS POWER SUPPLIES

MODEL #

PSH600-UPS (Kit)

PSH2RB10

·

PSM2RB10

·

PSH600-UPS-STAT (Kit)

PSH2C2RB10

·

PSMN2C2RB10

·

PSH850-UPS-STAT (Kit)

PSH2C2RB10-L

·

PSH600-UPS-BC (Kit)

STATUS
· · · · · ·

UPS 600 VA
600 VA
850 VA 600 VA

CIRCUIT 120 VAC BREAKER OUTLET(S)

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

Product Selection Guide. For full product information, see our website.

COMPATIBLE

KIT N/A PSH600-UPS

ENCLOSED
·
·

TRACK MOUNT

HEIGHT 12.000 12.000

WIDTH 14.000 14.000

DEPTH 6.000 6.000

PSH600-UPS

MT4-4N included 4.000 3.250 1.750

N/A

·

12.000 16.000 6.000

PSH600-UPS-STAT

·

12.000 16.000 6.000

PSH600-UPS-STAT

MT212-6N included 2.750 6.655 1.750

N/A

·

14.000 16.000 6.000

PSH850-UPS-STAT

·

14.000 16.000 6.000

·

N/A

·

12.000 16.000 6.000

= UL Listed : UL916 Energy Management; UL Listed Canada (800) 888-5538 | www.functionaldevices.com

25

FEATURED PRODUCTS

UNINTERRUPTIBLE POWER SUPPLY KIT

PSH600-UPS
Kit Consisting of Enclosed Power Control Center Model PSH2RB10 (10 Amp Switch / Circuit Breaker, Two (2) 120 Vac Outlets, Terminals, 120 Vac Input) with a 600 VA UPS. (No Status Contacts)

UPS

}

On/O Switch, Breaker To Protected 120 Vac & Indicator Light
Device Line Input

}

UPS Output

Line Input

RESET

Hot

OFF

Neut.

GND GND

Neut.

Hot

To UPS

Computer Outlet

From UPS

To UPS

SPECIFICATIONS
UPS
UPS: 600VA Backup Time: 2.5 Min. @ Full 600 VA Load
10 Min. @ 1/2 Load Power Consumption Up to 3 Amp @120 Vac
Max Load: 330 Watt Frequency: 50/60 Hz Temperature Rating of UPS: 32 to 104° F UPS Transfer Time: 6ms Approvals: UL Listed, UL1778
PSH2RB10
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing)
Main Breaker ON/OFF: Switch / Breaker (10 Amp) Approvals: UL Listed, UL916, C-UL, CE, RoHS
Dimensions: 12.000 x 14.000 x 6.000 Metal Housing with Screw Cover

Notes: · To order without UPS, so that any other commercial UPS with appropriate ratings and within housing space limitations may be used, see model PSH2RB10. · To order interface board for replacement or for separate use, order model PSM2RB10. · Average battery life: 3-5 years depending on the number of discharge cycles and environmental temperature · UPS may change based on quality and availability

Backup Time (Minutes)

Shown Without Cover
ESTIMATED BACKUP TIME VS. LOAD
Load (Watts)

26

Functional Devices, Inc. | American Made. American Owned.

FEATURED PRODUCTS

UNINTERRUPTIBLE POWER SUPPLY KIT

PSH600-UPS-STAT
Kit Consisting of Enclosed Power Control Center Model PSH2C2RB10 (10 Amp Switch / Circuit Breaker, Two (2) 120 Vac Outlets, Terminals, 120 Vac Input) with a 600VA UPS. (Status Contacts)

UPS Status Contacts & 120 Vac LED Indicator Line Input

Input Power Status Contacts & LED Indicator

GND }
Neut. Line

N/C }
COM N/O

N/C COM N/O

UPS

GND Neut. Line

RESET OFF

}

Line

Neut.

GND

From UPS Backed Up Outlet

}
}

To Protected Device
To UPS

UPS plugged into one of two outlets. Other outlet is spare.

SPECIFICATIONS
UPS
UPS: 600VA Backup Time: 2.5 Min. @ Full 600 VA Load
10 Min. @ 1/2 Load Power Consumption Up to 3 Amp @120 Vac
Max Load: 330 Watt Frequency: 50/60 Hz Temperature Rating of UPS: 32 to 104° F UPS Transfer Time: 6ms Approvals: UL Listed, UL1778
PSH2C2RB10
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing)
Main Breaker ON/OFF: Switch / Breaker (10 Amp) Approvals: UL Listed, UL916, C-UL, CE, RoHS
Dimensions: 12.000 x 16.000 x 6.000 Metal Housing with Screw Cover

Line Input Status Contacts and UPS Output Status Contacts Rated: 10 Amp @ 277 Vac General Use 10 Amp @ 30 Vdc (N/O) 7 Amp @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1/4 HP @ 277 Vac 1000 VA @ 120 Vac Magnetic Ballast (N/C) C300 Pilot Duty 16.8 VA @ 24 Vac Pilot Duty
Notes: · To order without UPS, so that any other commercial UPS with appropriate ratings and within housing space limitations may be used, see model PSH2C2RB10. · To order interface board for replacement or for separate use, order model PSMN2C2RB10. · Average battery life: 3-5 years depending on the number of discharge cycles and environmental temperature · UPS may change based on quality and availability

Backup Time (Minutes)

ESTIMATED BACKUP TIME VS. LOAD
Load (Watts)

(800) 888-5538 | www.functionaldevices.com

27

FEATURED PRODUCTS

WIRELESS DEVICES HVAC & Lighting Energy Management

Gateway/BMS
Key Card Switch
controls access to a room and turns on heating and lighting
when entering a room

Position Sensors
set back HVAC when windows are open

Occupancy Sensor
adjusts temperature and turns off lights when a
room is not in use
Batteryless Wireless Switches
control lighting

YOUR PAYBACK/ROI
· 70% COST SAVINGS IN RETROFITS · 40% ENERGY SAVINGS · UNLIMITED FLEXIBILITY

902 MHz · Maintenance-free Flexibility of applications · Time saving Cost savings in installation, renovation, and energy usage

Many hotels keep their rooms at a comfortable temperature for the duration of their guests' stays ­ whether the guests are in or out of their room. With guest comfort as a priority, hotels and motels typically use almost 40 percent of their electricity on heating and cooling rooms, even though studies show that most sold rooms are unoccupied for 12 or more hours a day. Used correctly, the right controls could offer significant energy savings without compromising the comfort of guests.

28

Information from: EnOcean® Alliance & ENERGY STAR Building Upgrade Manual Functional Devices, Inc. | American Made. American Owned.

FEATURED PRODUCTS

WIRELESS DEVICES

Wireless Solutions for BAS Applications

Unidirectional Control with a BAS Controller

BAS PanBeAlS Panel

Wht/RedWht/Red

DO

DO

Wht/BluWht/Blu LRN

CLR

RIBWxxxBRI-BENW3xxxB-EN3

LRN CLR
Wht or ReWd ht or Red Org Org
60Hz A/C Po60wHezr A/C Power
RIBWxxxBRI-BENW3xxxB-BElNk3 Blk or RIBWxoxrCR-EIBNW3 xxC-EN3

BAS Controller BAS Controller

Yel

Yel Load Load

In this application, the BAS system dry-contact output controls the transmitter on model RIBWxxxB-EN3, and a second RIBWxxxB-EN3 or RIBWxxC-EN3 is the receiver.

Bidirectional Control with a BAS Controller

BASBCAoSnCtroonltlreroller Org Org Yel Yel

BAS Panel
BWAhSt/PReadnaenld Wht/Blu
DO
Wht/Red and Wht/Blu
DO

LRN CLR

RIBWxxxB-EN3
DI
RIBWxxxB-EN3
DI

LRN CLR
RIBWxxxB-EN3 RIBWxxxB-EN3

Wht or Red
Org 60Hz AW/ChtPoowreRred OBrlkg
60Hz A/C Power
Blk

Yel

Load

RIBX Series

Yel

Wht/Red

(not included) Load
RIBX Series

Wht/Blu (not included) Wht/Red

Wht/Blu

In this application, the BAS system dry-contact output controls the transmitter on model RIBWxxxB-EN3. A second RIBWxxxB-EN3 receives the signal and activates its relay. A current switch detects current flow through the load and closes the dry-contact input on the second RIBWxxxB-EN3. The first RIBWxxxB-EN3 receives the transmission and closes its relay. This contact closure to the BAS system lets the controller know the load status.

EnOcean® Enabled 902 MHz Wireless Devices

Wireless Relays

Transmitter Switches

Vacancy/Occupancy Sensors

Ballast Mount Relay Receiver RIBWxxC-EN3

Nipple Mount Relay Transceiver
RIBWxxxB-EN3

Window/Door Position Switch
WDWS-EN3

Rocker Switch WWS2-EN3

Keycard Switch WKC-EN3

Wall Mount WVSWM-EN3

Ceiling Mount WVSCM-EN3

(800) 888-5538 | www.functionaldevices.com

29

FEATURED PRODUCTS

ENERGY SAVING DEVICES

LIGHT CONTROLLERS
FOR USE IN CLOSETS, PANTRIES, WALK-INS, AND CABINETS
Our Closet Light Controllers are designed to switch lighting loads on and off by the closing or opening of a variety of switches, including door jamb, magnetic, and ball switches. Models are available for retrofit and new contruction jobs, and with or without an energy-saving time out setting.

Retrofits

Retaining Clip

120 Vac Supply Neutral

To Light Fixture

Switched Leg

Octagonal Junction

Normally Open

Box with Knockout

Magnetic Door Switch

New Construction

Class 2 Wiring
CLC212
Closet Light
N/C Dry Contact Door Switch
(not included)

Light Fixture Junction Box

120 Vac Power

Class 2 Wiring

Line Neutral

Closet Door

Light Fixture
Blk Junction Box Wht Red

15 Minute Time Out 60 Minute Time Out

 · 5 Amp relay  · 120 Vac power  · Fits easily inside junction box  · Includes retaining clip  · No transformer needed
(dry contact input)  · Models CLC106, CLC106-NC  · Includes magnetic door jamb switch

 · 10 Amp N/O relay  · 120-277 Vac power  · No transformer needed (dry contact input)  · Light 18 AWG wire used to control relay,
instead of armored cable  · Available with time out setting  · Models CLC212, CLC212-D15, CLC212-D60  · Switch sold separately (models ACLCMAGSM & ACLCMAGDJ)

30

Functional Devices, Inc. | American Made. American Owned.

FEATURED PRODUCTS

LIGHTING CONTROLS

EMERGENCY LIGHTING
UL924 RELAYS
for Bypass/Shunt and Automatic Load Control Applications

FOR MORE PRODUCT INFORMATION:
www.functionaldevices.com/ul924

(800) 888-5538 | www.functionaldevices.com

31

FEATURED PRODUCTS

NOTES

32

Functional Devices, Inc. | American Made. American Owned.

RELAYS

PILOT RELAYS: 10­15 AMPS
RIBT2401D

RELAYS

RIBH1S

RIBU1C-N4

RIBMU1SC

RIBRL1C

Convenient Prepackaging is a Great Time Saver

· LED indicator

· 10-15 Amp models

· Multiple contact ratings

· Pre-wired

· Override / HOA switch options available · Enclosed or track mount

· High/low voltage separation available

· Time delay models

ENCLOSED PILOT RELAYS

COIL VOLTAGE

MODEL # RIBU1C

AC/DC
· 10-30

RELAY AC CONTACTS

RESISTIVE

120 1 SPDT 10 A @ 277 Vac

RIBH1C

·

10-30 208-277 1 SPDT

10 A @ 277 Vac

RIBU2C

· 10-30

120 2 SPDT 10 A @ 277 Vac

RIBH2C

·

10-30 208-277 2 SPDT

10 A @ 277 Vac

RIBL3C

· 10-30

3 SPST

10 A @ 277 Vac

RIBL4C RIBU1S

· 10-30 · 10-30

3 SPST, 1 SPDT

10 A @ 277 Vac

120

1 SPST

10 A @ 277 Vac

RIBH1S

·

10-30 208-277 1 SPST

10 A @ 277 Vac

RIBU1SM-250 · 10-30

120

1 SPST 10 A @ 120/250 Vac

RIBH1SM-250 · 10-30 208-277 1 SPST 10 A @ 120/250 Vac

RIB2401D

·

24

120 1 DPDT 10 A @ 277 Vac

RIB2402D

·

24

208-277 1 DPDT 10 A @ 277 Vac

RIBU1SC

· 10-30

120 1 SPDT 10 A @ 277 Vac

RIBH1SC

·

10-30 208-277 1 SPDT

10 A @ 277 Vac

RIBL1C-DC · 10-30 Vdc only

1 SPDT 10 A @ 277 Vac

RIB2421C

·

24

120-277 1 SPDT 10 A @ 277 Vac

RIBD2421C ~ ·

24

120-277 1 SPDT 10 A @ 277 Vac

RIBU2SC RIBU2S2

· 10-30 · 10-30

120

1 SPST, 1 SPDT

10 A @ 277 Vac

120

2 SPST

10 A @ 277 Vac

Product Selection Guide. For full product information, see our website.

CONTACT RATINGS
MOTOR 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O)

PILOT DUTY

HIGH/LOW OVERRIDE HOUSING SHIPPING SEPARATION SWITCH STYLE * WEIGHT

480 VA @ 240-277 Vac

A

0.300 lb.

480 VA @ 240-277 Vac

A

0.302 lb.

480 VA @ 240-277 Vac

B

0.507 lb.

480 VA @ 240-277 Vac

480 VA @ 240-277 Vac

·

B

0.528 lb.

C

0.742 lb.

480 VA @ 240-277 Vac

·

C

0.890 lb.

1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/2 HP @ 120/240 Vac (N/O) 1/2 HP @ 120/240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O)
1 HP @ 250 Vac 1 HP @ 250 Vac

480 VA @ 277 Vac 480 VA @ 277 Vac 345 VA @ 120/240 Vac 345 VA @ 120/240 Vac
B300 B300 480 VA @ 277 Vac 480 VA @ 277 Vac 480 VA @ 240-277 Vac C300 C300

1

B

0.404 lb.

1

B

0.410 lb.

1+monitor B

0.472 lb.

1+monitor B

0.520 lb.

A

0.336 lb.

A

0.350 lb.

2 +

B

0.445 lb.

2 +

B

0.447 lb.

A

0.285 lb.

A

0.301 lb.

·

C

0.642 lb.

1/3 HP @ 120-240 Vac (N/O) 480 VA @ 277 Vac

1/3 HP @ 120-240 Vac (N/O) 480 VA @ 277 Vac

·

1

B

0.526 lb.

2

C

0.735 lb.

= UL Listed : UL916 Energy Management, UL864 Fire ; USA & Canada

* = See Housing Guide on pages 86-87

~ = Time Delay

+ = SPDT with override requires 2 switches

# = Coil side relay override (requires unit to be powered)

For full product information, see data sheets on website. Shipping weights are approximate and may change due to packaging options.

34

Functional Devices, Inc. | American Made. American Owned.

PILOT RELAYS: 10­15 AMPS

RELAYS

T STYLE PILOT RELAYS

MODEL # RIBTU1C RIBTH1C RIBTU2C RIBTH2C RIBU1CW RIBH1CW RIBTU1S RIBTH1S RIBTU1SC RIBTH1SC RIBT2401D

COIL VOLTAGE

AC/DC

RELAY AC CONTACTS

· 10-30 120

1 SPDT

· 10-30 208-277 1 SPDT

· 10-30 120

2 SPDT

· 10-30 208-277 2 SPDT

· 10-30 120

1 SPDT

· 10-30 208-277 1 SPDT

· 10-30 120

1 SPST

· 10-30 208-277 1 SPST

· 10-30 120

1 SPDT

· 10-30 208-277 1 SPDT

· 24

120

1 DPDT

RESISTIVE 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 15 A @ 150 Vac 15 A @ 150 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac

Product Selection Guide. For full product information, see our website.

CONTACT RATINGS
MOTOR 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/2 HP @ 120-240 Vac (N/O)

PILOT DUTY 480 VA @ 240-277 Vac 480 VA @ 240-277 Vac 480 VA @ 240-277 Vac 480 VA @ 240-277 Vac 480 VA @ 240-277 Vac 480 VA @ 240-277 Vac
480 VA @ 277 Vac 480 VA @ 277 Vac 480 VA @ 277 Vac 480 VA @ 277 Vac
B300

HIGH/LOW OVERRIDE

SEPARATION SWITCH

·

·

·

·

·

·

·

1

·

1

·

2 +

·

2 +

·

HOUSING SHIPPING STYLE * WEIGHT

C

0.568 lb.

C

0.620 lb.

C

0.695 lb.

C

0.705 lb.

C

0.550 lb.

C

0.553 lb.

C

0.573 lb.

C

0.652 lb.

C

0.690 lb.

C

0.661 lb.

C

0.609 lb.

TRACK MOUNT PILOT RELAYS

MODEL # RIBRL1C RIBRL1S RIBR24D RIBR24SD

COIL VOLTAGE
AC/DC AC
· 1 10-30 · 1 10-30 · 1 24 · 1 24

RELAY CONTACTS
1 SPDT 1 SPDT
1 DPDT 1 DPDT

RESISTIVE 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac

RIBAN12C

· 2 12

1 SPDT 10 A @ 277 Vac

RIBAN24C

· 2 24

RIBM12C

· 12

RIBM12S

· 12

RIBM24C

· 24

RIBM24S

· 24

RIBM2401D

· 24

RIBM2402D

· 24

RIBMU1C

· 10-30

RIBMH1C

· 10-30

RIBMU1S

· 10-30

RIBMH1S

· 10-30

RIBMU2C

· 10-30

RIBMH2C

· 10-30

RIBMU1SM-250 · 10-30

RIBMH1SM-250 · 10-30

RIBMU1SC

· 10-30

RIBMH1SC

· 10-30

RIBMN12C

· 12

RIBMN12S

· 12

RIBMN24C

· 24

RIBMN24S

· 24

RIBMN24S-J

· 24

RIBMN24C-4T

·

24

RIBMN24S-4T

·

24

RIBMN2401D

· 24

RIBMNU1C

· 10-30

RIBMNH1C

· 10-30

RIBMNU1S

· 10-30

RIBMNH1S

· 10-30

RIBMNU1SM-250 · 10-30

RIBMNH1SM-250 · 10-30

120 208-277
120 208-277
120 208-277
120 208-277
120 208-277
120 208-277
120 120 208-277 120 208-277 120 208-277

1 SPDT
1 SPDT 1 SPST 1 SPDT 1 SPST 1 DPDT 1 DPDT 1 SPDT 1 SPDT 1 SPST 1 SPST 2 SPDT 2 SPDT 1 SPST 1 SPST 1 SPDT 1 SPDT 1 SPDT 1 SPST 1 SPDT 1 SPST 1 SPST 4 SPDT 4 SPST 1 DPDT 1 SPDT 1 SPDT 1 SPST 1 SPST 1 SPST 1 SPST

10 A @ 277 Vac
15 A @ 125 Vac 15 A @ 125 Vac 15 A @ 125 Vac 15 A @ 125 Vac 10 A @ 277 Vac 10 A @ 277 Vac 15 A @ 150 Vac 15 A @ 150 Vac 15 A @ 150 Vac 15 A @ 150 Vac 15 A @ 150 Vac 15 A @ 150 Vac 15 A @ 125 Vac 15 A @ 125 Vac 15 A @ 150 Vac 15 A @ 150 Vac 15 A @ 125 Vac 15 A @ 125 Vac 15 A @ 125 Vac 15 A @ 125 Vac 15 A @ 125 Vac 15 A @ 125 Vac 15 A @ 125 Vac 10 A @ 277 Vac 15 A @ 150 Vac 15 A @ 150 Vac 15 A @ 150 Vac 15 A @ 150 Vac 15 A @ 125 Vac 15 A @ 125 Vac

Product Selection Guide. For full product information, see our website.

CONTACT RATINGS
MOTOR 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/2 HP @ 120-240 Vac (N/O) 1/2 HP @ 120-240 Vac (N/O)
1 HP @ 250 Vac
1 HP @ 250 Vac
1 HP @ 250 Vac 1 HP @ 250 Vac 1 HP @ 250 Vac 1 HP @ 250 Vac 1/2 HP @ 120/240 Vac (N/O) 1/2 HP @ 120/240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1 HP @ 250 Vac 1 HP @ 250 Vac 1 HP @ 250 Vac 1 HP @ 250 Vac 1 HP @ 250 Vac 1 HP @ 250 Vac 1 HP @ 250 Vac 1/2 HP @ 120/240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O)

PILOT DUTY 480 VA @ 240/277 Vac 480 VA @ 240/277 Vac
B300 B300
C300
C300
C300 C300 C300 C300 B300 B300 480 VA @ 240-277 Vac 480 VA @ 240-277 Vac 480 VA @ 277 Vac 480 VA @ 277 Vac 480 VA @ 240-277 Vac 480 VA @ 240-277 Vac 345 VA @ 120/240 Vac (N/O) 345 VA @ 120/240 Vac (N/O) 480 VA @ 277 Vac 480 VA @ 277 Vac C300 C300 C300 C300 C300 C300 C300 B300 480 VA @ 240-277 Vac 480 VA @ 240-277 Vac 480 VA @ 277 Vac 480 VA @ 277 Vac 345 VA @ 120/240 Vac (N/O) 345 VA @ 120/240 Vac (N/O)

OVERRIDE SWITCH
1 # 1 #
1 1
1 1
1+monitor 1+monitor
2 3 2 3 1 1 1 4
1 1 1+monitor 1+monitor

TRACK SHIPPING MOUNT ^ WEIGHT

DIN Rail

0.184 lb.

DIN Rail

0.194 lb.

DIN Rail

0.285 lb.

DIN Rail

0.285 lb.

MT212 Series & DIN Rail

0.178 lb.

MT212 Series & DIN Rail

0.180 lb.

MT4 Series 0.111 lb.

MT4 Series 0.127 lb.

MT4 Series 0.110 lb.

MT4 Series 0.129 lb.

MT4 Series 0.160 lb.

MT4 Series 0.172 lb.

MT4 Series 0.134 lb.

MT4 Series 0.143 lb.

MT4 Series 0.150 lb.

MT4 Series 0.190 lb.

MT4 Series 0.249 lb.

MT4 Series 0.348 lb.

MT4 Series 0.218 lb.

MT4 Series 0.259 lb.

MT4 Series 0.178 lb.

MT4 Series 0.227 lb.

MT212 Series 0.087 lb.

MT212 Series 0.103 lb.

MT212 Series 0.087 lb.

MT212 Series 0.107 lb.

MT212 Series 0.120 lb.

MT212-6 Included 0.454 lb.

MT212-6 Included 0.550 lb.

MT212 Series 0.132 lb.

MT212 Series 0.136 lb.

MT212 Series 0.141 lb.

MT212 Series 0.177 lb.

MT212 Series 0.221 lb.

MT212 Series 0.263 lb.

MT212 Series 0.248 lb.

= UL Listed : UL916 Energy Management, UL864 Fire ; USA & Canada

1 = UL Listed : UL916 Energy Management ; USA & Canada

2 = UL Listed : UL508 only ; USA & Canada

+ = SPDT with override requires 2 switches

* = See Housing Guide on pages 86-87

^ = Track mount sold separately

# = Coil side relay override (requires unit to be powered)

For full product information, see data sheets on website. Shipping weights are approximate and may change due to packaging options.

(800) 888-5538 | www.functionaldevices.com

35

POWER RELAYS: 20­30 AMPS

RIBT2401D

RIB2421SB

RELAYS

RIB2402B

RIBM2401SBC

RIBM24ZL

Convenient Prepackaging is a Great Time Saver

· LED indicator · Multiple contact ratings · Override / HOA switch options available · High/low voltage separation available

· 20-30 Amp models · Pre-wired · Enclosed or track mount · Time delay models

ENCLOSED POWER RELAYS

MODEL #

RIB2401B ·

RIB2402B ·

RIB2401SB ·

RIB2402SB ·

RIB2421B ·

RIB2421SB ·

RIB2401SBC ·

RIB2402SBC ·

RIB01P

·

RIB02P

·

RIB347P ·

RIB04P

·

RIB013P ·

RIB023P ·

RIB043P ·

RIB243P ·

RIB24Z

·

RIB12P

·

RIB12P30 ·

RIB24P

·

RIB24P30 ·

RIB01P30 ·

RIB01P30-S ·

RIB02P30 ·

COIL VOLTAGE

RELAY AC/DC AC CONTACTS

24

120

1 SPDT

24

208-277

1 SPDT

24

120

1 SPST

24

208-277

1 SPST

24 120/208-277 1 SPDT

24 120/208-277 1 SPST

24

120

1 SPDT

24

208-277

1 SPDT

120

1 DPDT

208-277 1 DPDT

347

1 DPDT

480

1 DPDT

120

1 3PST

208-277

1 3PST

480

1 3PST

24

1 3PST

24

1 SPST N/O, 1 SPST N/C

12

1 DPDT

12

1 DPDT

24

1 DPDT

24

1 DPDT

120

1 DPST

120

1 DPST

208-277

1 DPST

RESISTIVE 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 300 Vac 20 A @ 300 Vac 20 A @ 300 Vac 20 A @ 300 Vac 20 A @ 300 Vac 20 A @ 300 Vac 20 A @ 300 Vac 20 A @ 300 Vac
30 A @ 300 Vac
20 A @ 300 Vac 30 A @ 300 Vac 20 A @ 300 Vac 30 A @ 300 Vac 30 A @ 300 Vac 30 A @ 300 Vac 30 A @ 300 Vac

Product Selection Guide. For full product information, see our website.

CONTACT RATINGS

MOTOR

PILOT DUTY

HIGH/LOW OVERRIDE HOUSING SHIPPING SEPARATION SWITCH STYLE * WEIGHT

2 HP @ 277 Vac

1,110 VA @ 277 Vac

B

0.500 lb.

2 HP @ 277 Vac

1,110 VA @ 277 Vac

B

0.501 lb.

2 HP @ 277 Vac

1,110 VA @ 277 Vac

1

B

0.497 lb.

2 HP @ 277 Vac

1,110 VA @ 277 Vac

1

B

0.510 lb.

2 HP @ 277 Vac

1,110 VA @ 277 Vac

B

0.525 lb.

2 HP @ 277 Vac

1,110 VA @ 277 Vac

1

B

0.540 lb.

2 HP @ 277 Vac

1,110 VA @ 277 Vac

2 +

B

0.565 lb.

2 HP @ 277 Vac

1,110 VA @ 277 Vac

3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac

·

2 +

B

0.598 lb.

C

0.956 lb.

3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac

·

3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac

·

3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac

·

7.5 HP @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac

·

7.5 HP @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac

·

7.5 HP @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac

·

7.5 HP @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac

·

C

0.965 lb.

C

0.952 lb.

C

0.952 lb.

C

1.008 lb.

C

1.020 lb.

C

0.993 lb.

C

0.974 lb.

3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac

B

0.748 lb.

3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac

3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac

3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac

3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac

3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac

·

3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac

·

3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac

·

B

0.725 lb.

B

0.888 lb.

B

0.724 lb.

B

0.874 lb.

C

0.982 lb.

1 #

C

1.013 lb.

C

0.980 lb.

= UL Listed : UL916 Energy Management, UL864 Fire ; USA & Canada

* = See Housing Guide on pages 86-87

+ = SPDT with override requires 2 switches

# = Coil side relay override (requires unit to be powered)

For full product information, see data sheets on website. Shipping weights are approximate and may change due to packaging options.

36

Functional Devices, Inc. | American Made. American Owned.

RELAYS

POWER RELAYS: 20­30 AMPS

T STYLE POWER RELAYS

COIL VOLTAGE

MODEL # RIBT24B

RELAY AC/DC AC CONTACTS RESISTIVE

· 24

1 SPDT 20 A @ 277 Vac

RIBT24SB

· 24

1 SPST 20 A @ 277 Vac

RIBT2401B

· 24

120

1 SPDT 20 A @ 277 Vac

RIBT2402B

· 24 208-277 1 SPDT 20 A @ 277 Vac

RIBT2401SB · 24

120

1 SPST 20 A @ 277 Vac

RIBT2402SB · 24 208-277 1 SPST 20 A @ 277 Vac

RIBT2401SBC · 24

120

1 SPDT 20 A @ 277 Vac

RIBT2402SBC · 24 208-277 1 SPDT 20 A @ 277 Vac

RIBTD2401B ~ · 24

120

1 SPDT 20 A @ 277 Vac

RIBT242B

· 24

2 SPDT 20 A @ 277 Vac

RIBT243B RIBT24P

· 24 · 24

2 SPST, 1 SPDT
1 DPDT

20 A @ 277 Vac 20 A @ 300 Vac

RIBT24Z RIBT243P

· 24 · 1 24

1 SPST N/O, 1 SPST N/C
3PST

30 A @ 300 Vac 20 A @ 300 Vac

Product Selection Guide. For full product information, see our website.

CONTACT RATINGS

MOTOR 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac

PILOT DUTY 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac

HIGH/LOW OVERRIDE HOUSING SHIPPING SEPARATION SWITCH STYLE * WEIGHT

·

C

0.675 lb.

·

1

C

0.673 lb.

·

C

0.663 lb.

·

C

0.670 lb.

·

1

C

0.674 lb.

·

1

C

0.676 lb.

·

2 +

C

0.790 lb.

·

2 +

C

0.806 lb.

·

C

0.735 lb.

·

C

0.863 lb.

2 HP @ 277 Vac

1,110 VA @ 277 Vac

·

C

0.961 lb.

3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac

·

C

0.930 lb.

3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac

·

C

0.983 lb.

7.5 HP @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac

·

C

0.980 lb.

TRACK MOUNT POWER RELAYS

COIL VOLTAGE

MODEL # RIBM2401B

AC/DC

·

24

RELAY AC CONTACTS RESISTIVE

120

1 SPDT 20 A @ 277 Vac

RIBM2402B

·

24

208-277

1 SPDT 20 A @ 277 Vac

RIBM2401SB

·

24

120

1 SPST 20 A @ 277 Vac

RIBM2402SB

·

24

208-277

1 SPST 20 A @ 277 Vac

RIBM2401SBC ·

24

120

1 SPDT 20 A @ 277 Vac

RIBM2402SBC ·

24

208-277

1 SPDT 20 A @ 277 Vac

RIBM24ZN RIBM24ZL RIBMN24ZL

24

·

24

·

24

1 DPDT 1 DPST 1 DPST

30 A @ 300 Vac 30 A @ 300 Vac 30 A @ 300 Vac

RIBM243PN

24

1 3PDT 30 A @ 300 Vac

RIBM013PN

120

1 3PDT 30 A @ 300 Vac

RIBM023PN

208-277

1 3PDT 30 A @ 300 Vac

RIBM043PN

480

1 3PDT 30 A @ 300 Vac

RIBM043PN-HD

480

1 3PDT 30 A @ 300 Vac

Product Selection Guide. For full product information, see our website.

CONTACT RATINGS

MOTOR 2 HP @ 277 Vac

PILOT DUTY 1,110 VA @ 277 Vac

OVERRIDE SWITCH

TRACK SHIPPING MOUNT ^ WEIGHT MT4 Series 0.171 lb.

2 HP @ 277 Vac

1,110 VA @ 277 Vac

MT4 Series 0.178 lb.

2 HP @ 277 Vac

1,110 VA @ 277 Vac

1

MT4 Series 0.208 lb.

2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac

1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac

1

MT4 Series 0.214 lb.

2 +

MT4 Series 0.242 lb.

2 +

MT4 Series 0.248 lb.

3 HP @ 480-600 Vac

NEMA B600

MT4 Series 0.283 lb.

3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac

MT4 Series 0.404 lb.

3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac

MT212 Series 0.403 lb.

7.5 HP @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac

MT4 Series 0.345 lb.

7.5 HP @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac

MT4 Series 0.368 lb.

7.5 HP @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac

MT4 Series 0.396 lb.

7.5 HP @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac

MT4 Series 0.358 lb.

7.5 HP @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac

MT4 Series 0.490 lb.

= UL Listed : UL916 Energy Management, UL864 Fire ; USA & Canada 1 = UL Listed : UL916 Energy Management ; USA & Canada = UL Component Recognized : UL916 Energy Management; USA & Canada

~ = Time Delay + = SPDT with override requires 2 switches

* = See Housing Guide on pages 86-87 ^ = Track mount sold separately

For full product information, see data sheets on website. Shipping weights are approximate and may change due to packaging options.

(800) 888-5538 | www.functionaldevices.com

37

LATCHING RELAYS

RELAYS

RIBL24BM

RIBL24B

RIBL12SB

These relays are switched by pulse commands from an appropriate power source or a controller. The relay contacts are mechanically latched in position, so that the load remains in its last state (on or off) during a loss of power. A pulse of opposing polarity latches the relay in the alternate state.

Product Features
· Prepackaged for quick and easy installation
· Electromechanical relay · Mechanically latching · Status LED and auxiliary ouput
models available · Electronic ballast rating · 20 Amp rating

Typical Application

24 Vac Supply
On Controller Comm
O

Latch Unlatch
N/O Momentary Wall Switch

Local Power
120-277 Vac Lighting
Status to Controller
N/O Momentary Wall Switch

ENCLOSED LATCHING RELAYS

MODEL # RIBL12B RIBL12SB

COIL VOLTAGE

AC/DC

RELAY CONTACTS

RESISTIVE

·

12

1 SPST 20 A @ 120-277 Vac

·

12

1 SPST 20 A @ 120-277 Vac

RIBL12BM ·

12

1 SPST 20 A @ 120-277 Vac

RIBL12SBM ·

12

1 SPST 20 A @ 120-277 Vac

RIBL24B

·

24

RIBL24SB

·

24

1 SPST 1 SPST

20 A @ 120-277 Vac 20 A @ 120-277 Vac

RIBL24BM ·

24

1 SPST 20 A @ 120-277 Vac

RIBL24SBM ·

24

1 SPST 20 A @ 120-277 Vac

Product Selection Guide. For full product information, see our website.

CONTACT RATINGS

MOTOR 3 HP @ 240 Vac 3 HP @ 240 Vac

PILOT DUTY 720 VA @ 120-277 Vac 720 VA @ 120-277 Vac

OVERRIDE SWITCH
·

AUXILIARY OUTPUT

HOUSING STYLE * A
A

SHIPPING WEIGHT 0.420 lb.
0.420 lb.

3 HP @ 240 Vac 720 VA @ 120-277 Vac

·

B

0.490 lb.

3 HP @ 240 Vac 720 VA @ 120-277 Vac

·

·

B

0.490 lb.

3 HP @ 240 Vac 720 VA @ 120-277 Vac

3 HP @ 240 Vac 720 VA @ 120-277 Vac

·

A

0.420 lb.

A

0.420 lb.

3 HP @ 240 Vac 720 VA @ 120-277 Vac

·

B

0.600 lb.

3 HP @ 240 Vac 720 VA @ 120-277 Vac

·

·

B

0.592 lb.

= UL Listed : UL916 Energy Management, UL864 Fire ; USA & Canada

* = See Housing Guide on pages 86-87

For full product information, see data sheets on website. Shipping weights are approximate and may change due to packaging options.

38

Functional Devices, Inc. | American Made. American Owned.

LOW-INPUT / OPTOISOLATED RELAYS

RELAYS

RIBTE24B

RIBME2401B

Optoisolated relays help isolate noisy loads from the controller. Good for controlling power relays from analog outputs.
Product Features
· Prepackaged for quick and easy installation · Extremely low current draw on the input · Control input can connect to AO for
relay control · Protect controller from feedback or
voltage transients

RIBTE02P-S

High Voltage 60 Hz ac

Controller
Digital Out (or Analog Out)

Power Supply

Relay

Opto Input

Opto RIB®

Load

Low Voltage

60 Hz ac

Controller 24 Vac/dc
Analog or Digital Out

Power Supply

Relay

Opto Input

Opto RIB®

Load

ENCLOSED LOW-INPUT / OPTOISOLATED RELAYS

Product Selection Guide. For full product information, see our website.

CONTACT RATINGS

MODEL #

RIBTELC

·

RIBTELS

·

RIBTE24B ·

RIBTE01B ·

RIBTE02B ·

RIBTE24SB ·

RIBTE01SB ·

RIBTE02SB ·

RIBTE24P ·

RIBTE01P ·

RIBTE02P ·

RIBTE01P-S ·

RIBTE02P-S ·

CONTROL INPUT
5-25 Vac/dc 5-25 Vac/dc 5-25 Vac/dc 5-25 Vac/dc 5-25 Vac/dc 5-25 Vac/dc 5-25 Vac/dc 5-25 Vac/dc 5-25 Vac/dc 5-25 Vac/dc 5-25 Vac/dc 5-25 Vac/dc 5-25 Vac/dc

POWER INPUT 10-30 Vac/dc 10-30 Vac/dc 24 Vac/dc 120 Vac 208-277 Vac 24 Vac/dc 120 Vac 208-277 Vac 24 Vac/dc 120 Vac 208-277 Vac 120 Vac 208-277 Vac

RELAY CONTACTS

RESISTIVE

1 SPDT 10 A @ 120-277 Vac

1 SPST 10 A @ 120-277 Vac

1 SPDT 20 A @ 277 Vac

1 SPDT 20 A @ 277 Vac

1 SPDT 20 A @ 277 Vac

1 SPST

20 A @ 277 Vac

1 SPST

20 A @ 277 Vac

1 SPST

20 A @ 277 Vac

1 DPDT 20 A @ 300 Vac

1 DPDT 20 A @ 300 Vac

1 DPDT 20 A @ 300 Vac

1 DPDT 20 A @ 300 Vac

1 DPDT 20 A @ 300 Vac

MOTOR 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O)
2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac 3 HP @ 480-600 Vac 3 HP @ 480-600 Vac 3 HP @ 480-600 Vac 3 HP @ 480-600 Vac 3 HP @ 480-600 Vac

PILOT DUTY 480 VA @ 240-277 Vac 480 VA @ 240-277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,640 VA @ 480 Vac 1,640 VA @ 480 Vac 1,640 VA @ 480 Vac 1,640 VA @ 480 Vac 1,640 VA @ 480 Vac

HIGH/LOW OVERRIDE

SEPARATION SWITCH

·

·

1

·

·

·

·

1

·

1

·

1

·

·

·

·

1 #

·

1 #

HOUSING STYLE * C C C C C C C C C C C C C

SHIPPING WEIGHT 0.578 lb. 0.666 lb. 0.711 lb. 0.730 lb. 0.734 lb. 0.760 lb. 0.743 lb. 0.747 lb. 0.976 lb. 0.995 lb. 1.015 lb. 1.034 lb. 1.068 lb.

TRACK MOUNT LOW-INPUT / OPTOISOLATED RELAYS

Product Selection Guide. For full product information, see our website.

CONTACT RATINGS

MODEL # RIBME2401B RIBME2402B

CONTROL

POWER

RELAY

INPUT

INPUT

CONTACTS RESISTIVE

· 5-25 Vac/dc 24 Vac/dc/120 Vac

1 SPDT 20 A @ 277 Vac

· 5-25 Vac/dc 24 Vac/dc/208-277 Vac 1 SPDT 20 A @ 277 Vac

MOTOR 2 HP @ 277 Vac 2 HP @ 277 Vac

PILOT DUTY 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac

OVERRIDE SWITCH

TRACK MOUNT ^ MT4 Series MT4 Series

SHIPPING WEIGHT 0.197 lb.
0.226 lb.

= UL Listed : UL916 Energy Management, UL864 Fire ; USA & Canada * = See Housing Guide on pages 86-87 ^ = Track mount sold separately # = Coil side relay override (requires unit to be powered) For full product information, see data sheets on website. Shipping weights are approximate and may change due to packaging options.

(800) 888-5538 | www.functionaldevices.com

39

POLARIZED / ALARM RELAYS

RIB24P-FA

RIBT24B-FA

RELAYS

RIB12S-FA

RIBMN12S-FA

RIB24C-FA-RD

These relays are polarized to work in a supervised system and may be turned on and off by reversing polarity. These prepackaged relays make installation quick and easy and can be used in fire alarm systems, smoke control systems, etc.

Product Features
· Coil input is polarity sensitive · For use with fire alarm systems · System supervision for controllers that utilize
end-of-line resistors · Four wire circuit ensures indication of broken
wiring connection with RIB® · Prepackaged for quick and easy installation

Typical Application

Load

Load

RIB24C-FA Coil
+­

RIB24C-FA Coil
+­

Controller

Signaling Circuit

End-ofLine
Resistor

ENCLOSED POLARIZED / ALARM RELAYS

CONTACT RATINGS

MODEL #
RIB12C-FA ·

COIL VOLTAGE
12 Vac/dc

RELAY CONTACTS
1 SPDT

RESISTIVE 10 A @ 277 Vac

MOTOR 1 HP @ 250 Vac

RIB24C-FA ·

24 Vac/dc

1 SPDT

10 A @ 277 Vac

1 HP @ 250 Vac

RIB12S-FA ·

12 Vac/dc

1 SPST

10 A @ 277 Vac

1 HP @ 250 Vac

RIB24S-FA ·

24 Vac/dc

1 SPST

10 A @ 277 Vac

1 HP @ 250 Vac

RIBT24B-FA ·

24 Vac/dc

1 SPDT

20 A @ 277 Vac

2 HP @ 277 Vac

RIB24P-FA ·

24 Vac/dc

1 DPDT

20 A @ 300 Vac 3 HP @ 480-600 Vac

Product Selection Guide. For full product information, see our website.

PILOT DUTY 770 VA @ 250 Vac 770 VA @ 250 Vac 770 VA @ 250 Vac 770 VA @ 250 Vac 1,110 VA @ 277 Vac 1,640 VA @ 480 Vac

HIGH/LOW OVERRIDE HOUSING SEPARATION SWITCH STYLE *
A

A

1

A

1

A

·

C

B

SHIPPING WEIGHT 0.293 lb. 0.291 lb. 0.290 lb. 0.291 lb. 0.660 lb. 0.755 lb.

TRACK MOUNT POLARIZED / ALARM RELAYS

CONTACT RATINGS

MODEL #
RIBMN12C-FA ·

COIL VOLTAGE
12 Vac/dc

RELAY CONTACTS
1 SPDT

RESISTIVE 15 A @ 125 Vac

MOTOR 1 HP @ 250 Vac

RIBMN24C-FA · 24 Vac/dc

1 SPDT

15 A @ 125 Vac

1 HP @ 250 Vac

RIBMN12S-FA · 12 Vac/dc

1 SPST

15 A @ 125 Vac

1 HP @ 250 Vac

RIBMN24S-FA · 24 Vac/dc

1 SPST

15 A @ 125 Vac

1 HP @ 250 Vac

Product Selection Guide. For full product information, see our website.

PILOT DUTY 770 VA @ 250 Vac 770 VA @ 250 Vac 770 VA @ 250 Vac 770 VA @ 250 Vac

OVERRIDE SWITCH
1 1

TRACK MOUNT ^ MT212 Series MT212 Series MT212 Series MT212 Series

SHIPPING WEIGHT 0.113 lb.
0.120 lb.
0.127 lb.
0.127 lb.

= UL Listed : UL916 Energy Management, UL864 Fire ; USA & Canada

* = See Housing Guide on pages 86-87

^ = Track mount sold separately

For full product information, see data sheets on website. Shipping weights are approximate and may change due to packaging options.

40

Functional Devices, Inc. | American Made. American Owned.

DRY CONTACT INPUT RELAYS
RIB01SBCDC

RELAYS

RIBD02BDC-DOB

RIB21CDC

RIBM01ZNDC

Product Features
· Prepackaged for quick and easy installation · Provides low-voltage (Class 2) power needed to activate the
relay (self-powered) by closing the dry contact input · Activated by a wide range of dry contacts such as
thermostats, switches, other relays, solid-state switches, etc. · Power to energize the relay can be brought to the relay on a
separate pair of wires along with the control output of the controller, or can be a local power source near the relay · Relay contacts are isolated from the input power and the dry contact input, so they can be wired to switch any other power-load or low-voltage load (see specifications for contact ratings)

Typical Application

Current sensing may be internal or external

Load Wire

Load 1

Local Power 120, 240, 277 Vac

RIBX Series
Current Sensor Only

(Class 2)

Current Sensor Status

Dry Contact Input RIB®

Load 2

Self-powered current switches of the RIBX Series and relays of the Dry Contact Input RIB® Series may be applied to interlock Load 2 to Load 1.

ENCLOSED DRY CONTACT INPUT RELAYS

MODEL #

RIB21CDC

·

RIB01BDC

·

RIB02BDC

·

RIB01SBDC

·

RIB02SBDC

·

RIB01SBCDC

·

RIB02SBCDC

·

RIBD01BDC ~

·

RIBD02BDC ~

·

RIBD01BDC-DOB ~ ·

RIBD02BDC-DOB ~ ·

POWER INPUT 120-277 Vac 120 Vac 208-277 Vac 120 Vac 208-277 Vac 120 Vac 208-277 Vac 120 Vac 208-277 Vac 120 Vac 208-277 Vac

RELAY CONTACTS
1 SPDT 1 SPDT 1 SPDT 1 SPST 1 SPST 1 SPDT 1 SPDT 1 SPDT 1 SPDT 1 SPDT 1 SPDT

RESISTIVE 10 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac

Product Selection Guide. For full product information, see our website.

CONTACT RATINGS

MOTOR

PILOT DUTY

HIGH/LOW OVERRIDE HOUSING SHIPPING SEPARATION SWITCH STYLE * WEIGHT

1 HP @ 250 Vac 770 VA @ 250 Vac

A

0.314 lb.

2 HP @ 277 Vac 1,110 VA @ 277 Vac

B

0.514 lb.

2 HP @ 277 Vac 1,110 VA @ 277 Vac

B

0.520 lb.

2 HP @ 277 Vac 1,110 VA @ 277 Vac

1

B

0.513 lb.

2 HP @ 277 Vac 1,110 VA @ 277 Vac

1

B

0.518 lb.

2 HP @ 277 Vac 1,110 VA @ 277 Vac

2

B

0.590 lb.

2 HP @ 277 Vac 1,110 VA @ 277 Vac

2 HP @ 277 Vac 1,110 VA @ 277 Vac

·

2

B

0.580 lb.

C

0.781 lb.

2 HP @ 277 Vac 1,110 VA @ 277 Vac

·

C

0.790 lb.

2 HP @ 277 Vac 1,110 VA @ 277 Vac

·

2 HP @ 277 Vac 1,110 VA @ 277 Vac

·

C

0.784 lb.

C

0.805 lb.

TRACK MOUNT DRY CONTACT INPUT RELAYS

Product Selection Guide. For full product information, see our website.

CONTACT RATINGS

MODEL #

POWER INPUT

RELAY CONTACTS

RESISTIVE

MOTOR

PILOT DUTY

OVERRIDE TRACK SHIPPING SWITCH MOUNT ^ WEIGHT

RIBM01ZNDC ·

120 Vac

1 DPDT

30 A @ 300 Vac

3 HP @ 480-600 Vac

B600

MT4 Series 0.352 lb.

RIBM02ZNDC · 208-277 Vac

1 DPDT

30 A @ 300 Vac

3 HP @ 480-600 Vac

B600

MT4 Series 0.356 lb.

RIBM013PNDC ·

120 Vac

1 3PDT

30 A @ 300 Vac 7.5 HP @ 480 Vac, 3 Phase 2122 VA @ 480 Vac, 3 Phase

MT4 Series 0.402 lb.

= UL Listed : UL916 Energy Management; USA & Canada

= UL Component Recognized : UL916 Energy Management; USA & Canada

~ = Time Delay

* = See Housing Guide on pages 86-87

^ = Track mount sold separately

For full product information, see data sheets on website. Shipping weights are approximate and may change due to packaging options.

(800) 888-5538 | www.functionaldevices.com

41

SPECIALTY PERIPHERAL CONTROLS

RIBLB-6

RIBMNLB-2

RELAYS

RIBMN24Q4C-PX

RIBMNA1D0

If we do not already build a device with specifications or packaging configurations you require, we will be happy to quote and design one for you. Functional Devices, Inc. is actively involved in the development, manufacturing, and production of special

peripheral devices. They are either variations of existing Functional Devices products or entirely unique devices. We will help provide you with a product to fit your specific needs. Please contact us so we may review your project and special requirements.

FAN SAFETY ALARM CIRCUITS / GENERAL PURPOSE LOGIC BOARDS

For full product information, see our website.

MODEL #

RIBMNLB

·

RIBLB

·

RIBMNWLB-7-BC ·

RIBMNLB-6

·

RIBMNLB-4

·

RIBMNLB-2

·

RIBMNLB-1

·

RIBLB-6

·

RIBLB-4

·

RIBLB-2

·

RIBMNLB-6NO

·

RIBMNLB-4NO

·

RIBMNLB-2NO

·

POWER INPUT 24 Vac 24 Vac 24 Vac 24 Vac 24 Vac 24 Vac 24 Vac 24 Vac 24 Vac 24 Vac 24 Vac 24 Vac 24 Vac

ALARM CIRCUITS 4 4 7 6 4 2 1 6 4 2 6 4 2

COMPATIBLE
·

HOUSING STYLE * D
D D D

TRACK MOUNT INCLUDED MT212-6
MT212-6 MT212-6 MT212-6 MT212-6 MT212-4
MT212-6 MT212-6 MT212-6

SHIPPING WEIGHT 0.566 lb. 1.127 lb. 0.587 lb. 0.624 lb. 0.516 lb. 0.332 lb. 0.286 lb. 1.187 lb. 1.088 lb. 1.000 lb. 0.637 lb. 0.533 lb. 0.343 lb.

I/O EXPANDERS

MODEL #

RIBMN24Q2C

· 1

RIBMN24Q3C

· 1

RIBMN24Q4C

· 1

RIBMN24Q4C-PX

· 1

POWER INPUT 24 Vac/dc 24 Vac/dc 24 Vac/dc 24 Vac/dc

Product Selection Guide. For full product information, see our website.

RELAY CONTACTS 2 SPDT 3 SPDT 4 SPDT 4 SPDT

TRACK MOUNT INCLUDED MT212-4 MT212-4 MT212-6 MT212-6

SHIPPING WEIGHT 0.296 lb. 0.354 lb. 0.494 lb. 0.493 lb.

MANUAL ANALOG OVERRIDE SWITCH

MODEL # RIBMNA1D0

POWER INPUT 24 Vac/dc

SWITCH Manual / Auto

Product Selection Guide. For full product information, see our website.

TRACK MOUNT ^ MT212 Series

SHIPPING WEIGHT 0.172 lb.

= UL Listed : UL916 Energy Management, UL864 Fire ; USA & Canada

1 = UL Listed : UL916 Energy Management ; USA & Canada

* = See Housing Guide on pages 86-87

^ = Track mount sold separately

For full product information, see data sheets on website. Shipping weights are approximate and may change due to packaging options.

42

Functional Devices, Inc. | American Made. American Owned.

NOTES

RELAYS

(800) 888-5538 | www.functionaldevices.com

43

NOTES

RELAYS

44

Functional Devices, Inc. | American Made. American Owned.

NETWORK COMPATIBLE
DEVICES

RIBTW2401B-BC

RIBTW2401SB-LN

RIBTW24SB-LNT2

NETWORK COMPATIBLE

RIBMW24SB-LNT2

RIBMNWD12-BC

RIBMW24B-44-BC

NETWORK COMPATIBLE DEVICES
Our Network Compatible Devices can be hard wired and used instead of more expensive multioutput controllers when a few more control points are needed, and large controllers are too much for the job. They can also be used when control points are widely spread throughout the job site. These devices have been prepackaged to save the installer the time, trouble, and expense of buying separate components and assembling them on the job.
Product Features
· BACnet®, LonWorks®, Wi-Fi and Modbus protocols · Analog input · Analog output · Binary output · Binary input · Thermistor inputs available · On-board current sensors available · Track mount and enclosed versions · NEMA 4X available · UL Listed

46

Functional Devices, Inc. | American Made. American Owned.

NETWORK COMPATIBLE DEVICES

NETWORK COMPATIBLE

BACNET® DEVICES
POWER INPUT

CONTACT RATINGS

Product Selection Guide. For full product information, see our website.

MODEL #
RIBTW2401B-BC · RIBTW2402B-BC · RIBMNWX2401B-BC · RIBTWX2401B-BC · RIBMNWX2402B-BC · RIBTWX2402B-BC · RIBMNW24B-BCAI · RIBTW24B-BCAI · RIBTW24B-BCAO · RIBMNWD12-BCDI · RIBMNWD12-BC · RIBMW24B-44-BC ·

AC/DC 24 24 24 24 24 24 24 24 24 24 24 24

AC 120 208-277 120 120 208-277 208-277

RELAY CONTACTS 1 SPDT 1 SPDT 1 SPDT 1 SPDT 1 SPDT 1 SPDT 1 SPDT 1 SPDT 1 SPDT
4 SPDT

RESISTIVE 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac
20 A @ 277 Vac

MOTOR 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac
2 HP @ 277 Vac

PILOT DUTY 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac
1,110 VA @ 277 Vac

DRY

TRACK

CONTACT

ACCUMU- INTERNAL PRECON®

MOUNT /

BINARY ANALOG ANALOG LATOR CURRENT THERMISTOR OVERRIDE HOUSING SHIPPING

INPUT INPUT OUTPUT INPUT SENSOR INPUT SWITCH STYLE * WEIGHT

1

#

C 0.846 lb.

1

#

C 0.864 lb.

1

·

# MT212-6 0.532 lb.

1

·

#

D 1.060 lb.

1

·

# MT212-6 0.532 lb.

1

·

#

D 1.092 lb.

2

1

10k Type 2 or 3 # MT212-6 0.522 lb.

2

1

10k Type 2 or 3 #

D 1.096 lb.

1

1

1

10k Type 2 or 3 #

D 1.040 lb.

12

MT212-6 0.512 lb.

12

2

MT212-6 0.540 lb.

4

# MT4-6 0.830 lb.

OTHER BACNET® DEVICES: Fan Safety Alarm Circuit / General Purpose Logic Board (pg. 44) and UPS Kit (pg. 71)

LONMARK® DEVICES

Product Selection Guide. For full product information, see our website.

POWER INPUT

CONTACT RATINGS

MODEL #

AC/DC

RELAY AC CONTACTS RESISTIVE

MOTOR

PILOT DUTY

DRY

CONTACT

INTERNAL PRECON®

BINARY ANALOG CURRENT THERMISTOR OVERRIDE

INPUT INPUT SENSOR INPUT SWITCH

TRACK MOUNT / HOUSING STYLE *

SHIPPING WEIGHT

RIBTW2401B-LN · 24

120 1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac 1

C

0.823 lb.

RIBTW2402B-LN · 24 208-277 1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac 1

C

0.820 lb.

RIBTW2401SB-LN · 24

120 1 SPST 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac 1

1

C

0.840 lb.

RIBTW2402SB-LN · 24 208-277 1 SPST 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac 1

1

C

0.804 lb.

RIBMNWX2401SB-LN · 24

120 1 SPST 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac

·

1

MT212-6 0.530 lb.

RIBTWX2401SB-LN · 24

120 1 SPST 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac

·

1

D

1.065 lb.

RIBMNWX2402SB-LN · 24 208-277 1 SPST 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac

·

1

MT212-6 0.538 lb.

RIBTWX2402SB-LN · 24 208-277 1 SPST 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac

·

1

D

1.024 lb.

RIBMW24SB-LNAI · 24

1 SPST 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac 1

1

1

MT4-4 0.500 lb.

RIBTW24SB-LNAI · 24

1 SPST 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac 1

1

1

D

1.027 lb.

RIBMW24SB-LNT2 · 24

1 SPST 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac 1

10k Type 2

1

MT4-4 0.476 lb.

RIBTW24SB-LNT2 · 24

1 SPST 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac 1

10k Type 2

1

D

1.020 lb.

RIBMW24SB-LNT3 · 24

1 SPST 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac 1

10k Type 3

1

MT4-4 0.476 lb.

RIBTW24SB-LNT3 · 24

1 SPST 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac 1

10k Type 3

1

D

1.056 lb.

WI-FI DEVICES
POWER INPUT

MODEL #

AC/DC AC

RIBTW24B-WI-N4

· 24

RIBTW2401B-WIUI-N4 · 24 120

RELAY CONTACTS
1 SPDT
1 SPDT

RESISTIVE 20 A @ 277 Vac 20 A @ 277 Vac

Product Selection Guide. For full product information, see our website.

CONTACT RATINGS

MOTOR

PILOT DUTY

DRY CONTACT UNIVERSAL OVERRIDE HOUSING SHIPPING

BINARY INPUT INPUT

SWITCH STYLE * WEIGHT

2 HP @ 277 Vac 1,110 VA @ 277 Vac

1

#

D

0.830 lb.

2 HP @ 277 Vac 1,110 VA @ 277 Vac

1

2

#

D

1.454 lb.

MODBUS DEVICES
POWER INPUT

Product Selection Guide. For full product information, see our website. CONTACT RATINGS

PRECON®

RELAY

DRY CONTACT ANALOG THERMISTOR OVERRIDE TRACK MOUNT / SHIPPING

MODEL #

AC/DC AC CONTACTS RESISTIVE

MOTOR

PILOT DUTY BINARY INPUT INPUT

INPUT

SWITCH HOUSING STYLE * WEIGHT

RIBMNW24B-MBAI · 24

1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac

2

1

10k Type 2

#

MT212-6

0.532 lb.

RIBTW24B-MBAI · 24

1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac

2

1

10k Type 2

#

D

1.074 lb.

= UL Listed : UL916 Energy Management; USA & Canada

= UL Component Recognized : UL916 Energy Management; USA & Canada

# = Coil Side Relay Override (requires unit to be powered)

* = See Housing Guide on pages 86-87

^ = Track mount included

Precon® is a registered trademark of Kele and Associates.

For full product information, see data sheets on website. Shipping weights are approximate and may change due to packaging options.

(800) 888-5538 | www.functionaldevices.com

47

NOTES

NETWORK COMPATIBLE

48

Functional Devices, Inc. | American Made. American Owned.

CURRENT SENSORS

RIBMX24BV

RIBX24SBA

RIBHX24BA

CURRENT SENSORS

RIBXGTV10

RIBXKTA

RIB® CURRENT SENSORS, TRANSDUCERS, AND RELAY AND SENSOR COMBOS ARE PREPACKAGED TO MAKE INSTALLATION EASY

· Prepackaged: Sensor, LED indicators, and wires or terminals
· Some models available with 10 Amp or 20 Amp relay
· Sense up to 150 Amps
· Split and solid core models
· Fixed or adjustable thresholds

· Hi/Low voltage separation · Transducers with voltage output
or 4-20mA regulation available · Enclosed or track mount · HOA switches available · UL Listed · Made in the USA

Functional Devices Certified for use with ECMs

· RIBXKA · RIBXKF · RIBXKTA · RIBXKTF · RIBXGA · RIBXGF · RIBXGTA · RIBXGTF

· RIBXG21A · RIBXG21F · RIBXG21TA · RIBXG21TF · RIBXGA-SCAL · RIBXGTA-SCAL · RIBXGFL · RIBXGHA

· RIBXGHF · RIBXGHTA · RIBXGHTF · RIBXGTFL · RIBXA · RIBXF · RIBXJA · RIBXJF

· RIBXRA · RIBXRF · RIBHX24BF · RIBX243PA · RIBX243PF · RIBX24BA · RIBX24BF · RIBX24SBA

· RIBX24SBF · RIBXLCA · RIBXLCF · RIBXLCJA · RIBXLCJF · RIBXLCRA · RIBXLCRF · RIBXLSA

· RIBXLSF · RIBXLSJA · RIBXLSJF · RIBXLSRA · RIBXLSRF · RIBMX24BA · RIBMX24BF · RIBMX24SBA · RIBMX24SBF

50

Functional Devices, Inc. | American Made. American Owned.

CURRENT SENSORS

CURRENT SENSORS

SOLID AND SPLIT CORE AC SENSORS

MODEL # RIBXKF

SENSING

SENSOR CONTACT

RANGE TYPE THRESHOLD

TYPE

· .25-150 A Solid Fixed, .25 Amp Solid State Switch SPST

RIBXKTF

· .25-150 A Solid Fixed, .25 Amp Solid State Switch SPST

RIBXKA

· .50-150 A Solid Adjustable Solid State Switch SPST

RIBXKTA

· .50-150 A Solid Adjustable Solid State Switch SPST

RIBXGHF

· 1 .50-150 A Split Fixed, .50 Amp Solid State Switch SPST

RIBXGHTF

· 1 .50-150 A Split Fixed, .50 Amp Solid State Switch SPST

RIBXGHA

· 1 .75-150 A Split Adjustable Solid State Switch SPST

RIBXGHTA

· 1 .75-150 A Split Adjustable Solid State Switch SPST

RIBXGF

· .35-150 A Split Fixed, .35 Amp Solid State Switch SPST

RIBXGFL

· .75-150 A Split Fixed, .75 Amp Solid State Switch SPST

RIBXGTF

· .35-150 A Split Fixed, .35 Amp Solid State Switch SPST

RIBXGTFL

· .75-150 A Split Fixed, .75 Amp Solid State Switch SPST

RIBXGA

· .75-150 A Split Adjustable Solid State Switch SPST

RIBXGTA

· .75-150 A Split Adjustable Solid State Switch SPST

RIBXGA-SCAL · 3-150 A Split Self-Calibrating Solid State Switch SPST

RIBXGTA-SCAL · 3-150 A Split Self-Calibrating Solid State Switch SPST

RIBXG21F

· 1 .50-150 A Split Fixed, .50 Amp Solid State Switch SPST

RIBXG21TF · 1 .50-150 A Split Fixed, .50 Amp Solid State Switch SPST

RIBXG21A

· 1 .75-150 A Split Adjustable Solid State Switch SPST

RIBXG21TA · 1 .75-150 A Split Adjustable Solid State Switch SPST

RIBXKTV5-10 · 0-10 A Solid Analog

RIBXKTV5-20 · 0-20 A Solid Analog

RIBXKTV5-50 · 0-50 A Solid Analog

RIBXKTV5-100 · 0-100 A Solid Analog

RIBXK420-20 · 0-20 A Solid Analog

RIBXK420-50 · 0-50 A Solid Analog

RIBXK420-100 · 0-100 A Solid Analog

RIBXGTV5 RIBXGTV10 RIBXG420-20

·

0-20 A, 0-50 A, 0-100 A

Split

·

0-20 A, 0-50 A, 0-100 A

Split

· 2 0-20 A Split

Analog Analog Analog

RIBXG420-50 · 2 0-50 A Split Analog

RIBXG420-100 · 2 0-100 A Split Analog

Product Selection Guide. For full product information, see our website.

SWITCHING MAX. SWITCHING VOLTAGE RANGE CURRENT

30 Vac/dc

.4 Amps Max

SENSOR CONTACT TERMINATION
Wht/Yel 16 18 AWG Wire Leads

SENSOR SHIPPING OUTPUT * WEIGHT
0.175 lb.

30 Vac/dc

.4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire

0.146 lb.

30 Vac/dc

.8 Amps Max

Wht/Yel 16 18 AWG Wire Leads

0.175 lb.

30 Vac/dc

.8 Amps Max Terminal Strip, Accepts #14-22 AWG Wire

0.147 lb.

120 Vac only

1 Amp Max

Wht/Blk 16 18 AWG Wire Leads

0.291 lb.

120 Vac only

1 Amp Max Terminal Strip, Accepts #14-22 AWG Wire

0.243 lb.

120 Vac only

1 Amp Max

Wht/Blk 16 18 AWG Wire Leads

0.286 lb.

120 Vac only

1 Amp Max Terminal Strip, Accepts #14-22 AWG Wire

0.249 lb.

30 Vac/dc

.4 Amps Max

Wht/Yel 16 18 AWG Wire Leads

0.273 lb.

30 Vac/dc

.4 Amps Max

Wht/Yel 16 18 AWG Wire Leads

0.280 lb.

30 Vac/dc

.4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire

0.235 lb.

30 Vac/dc

.4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire

0.240 lb.

30 Vac/dc

.4 Amps Max

Wht/Yel 16 18 AWG Wire Leads

0.276 lb.

30 Vac/dc

.4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire

0.243 lb.

30 Vac/dc

.4 Amps Max

Wht/Yel 16 18 AWG Wire Leads

0.292 lb.

30 Vac/dc

.4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire

0.248 lb.

120-277 Vac

1 Amp Max

Wht/Blk 16 18 AWG Wire Leads

0.288 lb.

120-277 Vac

1 Amp Max Terminal Strip, Accepts #14-22 AWG Wire

0.243 lb.

120-277 Vac

1 Amp Max

Wht/Blk 16 18 AWG Wire Leads

0.290 lb.

120-277 Vac

1 Amp Max Terminal Strip, Accepts #14-22 AWG Wire

0.244 lb.

Terminal Strip, Accepts #14-22 AWG Wire 0-5 Vdc 0.148 lb.

Terminal Strip, Accepts #14-22 AWG Wire 0-5 Vdc 0.150 lb.

Terminal Strip, Accepts #14-22 AWG Wire 0-5 Vdc 0.151 lb.

Terminal Strip, Accepts #14-22 AWG Wire 0-5 Vdc 0.149 lb.

Red & Blk 16 18 AWG Wire Leads

4-20 mA 0.178 lb.

Red & Blk 16 18 AWG Wire Leads

4-20 mA 0.180 lb.

Red & Blk 16 18 AWG Wire Leads

4-20 mA 0.180 lb.

Terminal Strip, Accepts #14-22 AWG Wire 0-5 Vdc 0.246 lb.

Terminal Strip, Accepts #14-22 AWG Wire
Red & Blk 16 18 AWG Wire Leads Red & Blk 16 18 AWG Wire Leads Red & Blk 16 18 AWG Wire Leads

0-10 Vdc
4-20 mA 4-20 mA 4-20 mA

0.246 lb.
0.284 lb. 0.276 lb. 0.284 lb.

T STYLE AC SENSORS

MODEL # RIBXF

SENSING RANGE TYPE THRESHOLD
· .50-30 A Internal Fixed, .50 Amp

RIBXA

· .50-30 A Internal Adjustable

RIBXV

· 0-30 A Internal Analog

RIBXRF

· 1.25-150 A Solid Fixed, 1.25 Amp

RIBXRA · 1.25-150 A Solid Adjustable

RIBXJF

· 3-150 A Split Fixed, 3 Amp

RIBXJA

· 3-150 A Split Adjustable

SENSOR CONTACT TYPE Solid State Switch SPST Solid State Switch SPST
Solid State Switch SPST Solid State Switch SPST Solid State Switch SPST Solid State Switch SPST

Product Selection Guide. For full product information, see our website.

SWITCHING MAX. SWITCHING VOLTAGE RANGE CURRENT

SENSOR CONTACT TERMINATION

SENSOR OUTPUT

SHIPPING WEIGHT

30 Vac/dc

.4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire

0.828 lb.

30 Vac/dc

.4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire

0.835 lb.

Terminal Strip, Accepts #14-22 AWG Wire 0-5 Vdc / 0-10 Vdc 0.833 lb.

30 Vac/dc

.4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire

0.684 lb.

30 Vac/dc

.4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire

0.676 lb.

30 Vac/dc

.4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire

0.759 lb.

30 Vac/dc

.4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire

0.759 lb.

= UL Listed : UL916 Energy Management, UL864 Fire ; USA & Canada
* = 4-20 mA is Loop Powered

1 = UL Listed : UL916 Energy Management ; USA & Canada

2 = UL Listed : UL864 Fire, UL508 Industrial Control ; USA & Canada

Refer to Housing Guide on pages 86-87 or product data sheet for housing information.

For full product information, see data sheets on website. Shipping weights are approximate and may change due to packaging options.

(800) 888-5538 | www.functionaldevices.com

51

CURRENT SENSOR & RELAY COMBINATIONS

CURRENT SENSORS

ENCLOSED AC SENSORS WITH RELAYS

MODEL # RIBHX24BF RIBHX24BA RIBXLCF RIBXLCA

COIL

RELAY

VOLTAGE CONTACTS

· 1 24 Vac 1 SPST-N/O

· 1 24 Vac 1 SPST-N/O

· 10-30 Vac/dc 1 SPDT

· 10-30 Vac/dc 1 SPDT

OVERRIDE SWITCH

RESISTIVE 20 A @ 277 Vac 20 A @ 277 Vac 10 A @ 120-277 Vac 10 A @ 120-277 Vac

SENSING RANGE .25-20 A
.25-20 A
.50-10 A
.50-10 A

RIBXLCV

· 10-30 Vac/dc 1 SPDT

10 A @ 120-277 Vac 0-10 A

RIBXLCRF RIBXLCRA RIBXLCJF RIBXLCJA RIBXLCEA

· 10-30 Vac/dc · 10-30 Vac/dc · 10-30 Vac/dc · 10-30 Vac/dc · 10-30 Vac/dc

1 SPDT 1 SPDT 1 SPDT 1 SPDT 1 SPDT

10 A @ 120-277 Vac 10 A @ 120-277 Vac 10 A @ 120-277 Vac 10 A @ 120-277 Vac
5 A @ 277 Vac

1.25-150 A 1.25-150 A 3-150 A 3-150 A .125 - 5 A

RIBXLCEV · 10-30 Vac/dc 1 SPDT

5 A @ 277 Vac

0 - 5 A

RIBXLSF

· 10-30 Vac/dc 1 SPST

1

10 A @ 277 Vac .50-10 A

RIBXLSA

· 10-30 Vac/dc 1 SPST

1

10 A @ 277 Vac .50-10 A

RIBXLSV

· 10-30 Vac/dc 1 SPST

1

10 A @ 277 Vac 0 - 10 A

RIBXLSRF · 10-30 Vac/dc 1 SPST

1

10 A @ 277 Vac 1.25-150 A

RIBXLSRA · 10-30 Vac/dc 1 SPST

1

10 A @ 277 Vac 1.25-150 A

RIBXLSJF · 10-30 Vac/dc 1 SPST

1

10 A @ 277 Vac 3-150 A

RIBXLSJA · 10-30 Vac/dc 1 SPST

1

10 A @ 277 Vac 3-150 A

RIBXLSEA · 10-30 Vac/dc 1 SPST

1

5 A @ 277 Vac .125 - 5 A

RIBXLSEV · 10-30 Vac/dc 1 SPST

1

5 A @ 277 Vac

0 - 5 A

RIBX24BF RIBX24BA

· 24 Vac/dc · 24 Vac/dc

1 SPDT 1 SPDT

20 A @ 277 Vac 20 A @ 277 Vac

.50-20 A .50-20 A

RIBX24BV · 24 Vac/dc 1 SPDT

20 A @ 277 Vac 0-20 A

RIBX24SBF · 24 Vac/dc 1 SPST

1

20 A @ 277 Vac .50-20 A

RIBX24SBA · 24 Vac/dc 1 SPST

1

20 A @ 277 Vac .50-20 A

RIBX24SBV · 24 Vac/dc 1 SPST

1

20 A @ 277 Vac 0-20 A

RIBX243PF · 1 24 Vac/dc RIBX243PA · 1 24 Vac/dc RIBX243PV · 1 24 Vac/dc

1 3PST 1 3PST 1 3PST

20 A @ 300 Vac 20 A @ 300 Vac 20 A @ 300 Vac

.50-20 A .50-20 A 0-20 A

Product Selection Guide. For full product information, see our website.

TYPE * Internal

THRESHOLD Fixed, .25 Amp

SENSOR CONTACT TYPE

SWITCHING MAX. VOLTAGE SWITCHING RANGE CURRENT

Solid State Switch Contact 30 Vac/dc .1 Amps Max

SENSOR OUTPUT

SHIPPING WEIGHT
0.407 lb.

Internal Adjustable Solid State Switch Contact 30 Vac/dc .1 Amps Max

0.407 lb.

Internal Fixed, .50 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max

0.758 lb.

Internal Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max

0.770 lb.

Internal Analog

0-5 Vdc / 0-10 Vdc

0.780 lb.

External Fixed, 1.25 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max

0.820 lb.

External Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max

0.768 lb.

External Fixed, 3 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max

0.913 lb.

External Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max

0.867 lb.

Internal Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max

0.787 lb.

Internal Analog

0-5 Vdc / 0-10 Vdc

0.777 lb.

Internal Fixed, .50 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max

0.786 lb.

Internal Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max

0.792 lb.

Internal Analog

0-5 Vdc / 0-10 Vdc

0.795 lb.

External Fixed, 1.25 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max

0.852 lb.

External Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max

0.768 lb.

External Fixed, 3 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max

0.942 lb.

External Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max

0.898 lb.

Internal Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max

0.856 lb.

Internal Analog

0-5 Vdc / 0-10 Vdc

0.840 lb.

Internal Fixed, .50 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max

0.880 lb.

Internal Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max

0.890 lb.

Internal Analog

0-5 Vdc / 0-10 Vdc

0.887 lb.

Internal Fixed, .50 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max

0.877 lb.

Internal Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max

0.882 lb.

Internal Analog

0-5 Vdc / 0-10 Vdc

0.906 lb.

Internal Fixed, .50 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max

1.190 lb.

Internal Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max

1.190 lb.

Internal Analog

0-10 Vdc 1.207 lb.

TRACK MOUNT AC SENSORS WITH RELAYS

Product Selection Guide. For full product information, see our website.

MODEL # RIBRXLCF

COIL

RELAY

VOLTAGE CONTACTS

· 1 10-30 Vac/dc 1 SPST

OVERRIDE SWITCH

RESISTIVE 10 A @ 277 Vac

SENSING RANGE
.25-10 A

TYPE * Internal

THRESHOLD Fixed, .25 Amp

SENSOR CONTACT TYPE

SWITCHING MAX. VOLTAGE SWITCHING RANGE CURRENT

Solid State Switch Contact 30 Vac/dc .4 Amps Max

SENSOR OUTPUT

TRACK MOUNT SHIPPING
^ WEIGHT
DIN Rail 0.285 lb.

RIBRXLCA · 1 10-30 Vac/dc 1 SPST

10 A @ 277 Vac .25-10 A Internal Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max

DIN Rail 0.285 lb.

RIBRXLSA · 1 10-30 Vac/dc 1 SPST

1 10 A @ 277 Vac .25-10 A Internal Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max

DIN Rail 0.285 lb.

RIBMX24BF · 24 Vac/dc 1 SPDT

20 A @ 277 Vac .50-20 A Internal Fixed, .50 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max

MT4 Series 0.410 lb.

RIBMX24BA · 24 Vac/dc 1 SPDT

20 A @ 277 Vac .50-20 A Internal Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max

MT4 Series 0.410 lb.

RIBMX24SBF · 24 Vac/dc 1 SPST

1 20 A @ 277 Vac .50-20 A Internal Fixed, .50 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max

MT4 Series 0.438 lb.

RIBMX24SBA · 24 Vac/dc 1 SPST

1 20 A @ 277 Vac .50-20 A Internal Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max

MT4 Series 0.446 lb.

RIBMX24SBV · 24 Vac/dc 1 SPST

1 20 A @ 277 Vac 0-20 A Internal Analog

0-5 Vdc / 0-10 Vdc

MT4 Series

0.408 lb.

= UL Listed : UL916 Energy Management, UL864 Fire ; USA & Canada

1 = UL Listed : UL916 Energy Management ; USA & Canada

* = Internal current sensor monitors current through common contact of relay ^ = Track mount sold separately Refer to Housing Guide on pages 86-87 or product data sheet for housing information.

For full product information, see data sheets on website. Shipping weights are approximate and may change due to packaging options.

52

Functional Devices, Inc. | American Made. American Owned.

NOTES

CURRENT SENSORS

(800) 888-5538 | www.functionaldevices.com

53

NOTES

CURRENT SENSORS

54

Functional Devices, Inc. | American Made. American Owned.

POWER SUPPLIES

PSH100A100AB10

PSH300A-LVC

PSH40AB10

POWER SUPPLIES

PSM19A24DAS

PSMN40A24DS

PSP24DA

AC & DC POWER SUPPLIES

· 40 - 500 VA AC models · Single & dual transformers · Prepackaged power supply kits

· Class 2 models · On/off control · Overcurrent protection

· LED power indicator · High/low voltage separation · 120 Vac convenience outlets

500, 300 & 200 VA Power Supplies are Perfect for VAV & Zone and Network Controller Applications

· 5 or 3 isolated 100 VA or 5 isolated 40 VA outputs · On/Off circuit breaker switch for each output · UL Listed Class 2

· Enclosed or sub-panel mount · Low voltage compartment models available · 120 Vac convenience outlet available

Mounting Your Controller and Peripheral Devices is Easy and Convenient in our Prepackaged Power Supply Solutions
Metal Enclosure, Power Supply, and Sub-Panel with Several Options to Fit Your Needs
If you plan to install a controller and other peripheral devices, an important consideration is where the items will be placed within an enclosure and how they will be powered. We have a line of products that can address both of those needs: the MHP Series. These products include a metal enclosure, power supply and a sub-panel with several prepackaged options to meet your specific needs.

56

Functional Devices, Inc. | American Made. American Owned.

AC POWER SUPPLIES

POWER SUPPLIES

AC POWER SUPPLIES: 40-100 VA

MODEL # PSB40AB10 PSB100AB10 PSC40AB10 PSC100AB10 PSMN40A PSMN40AS PSH40A PSH40AW PSH40AB10 PSH40AB10-EXT2 PSH40AWB10 PSH75A PSH75AW PSH75AB10 PSH75AWB10 PSH100A PSH100AW PSH100AB10 PSH100AB10-EXT2 PSH100AWB10 PSH75A75A PSH75A75AW PSH75A75AB10 PSH75A75AWB10 PSH100A100A PSH100A100AW PSH100A100AB10 PSH100A100AWB10

TRANSFORMER(S)

· 1

40 VA

INPUT POWER 120 Vac

HEIGHT 5.200

· 1

100 VA

120 Vac

5.200

· 1

40 VA

120 Vac

6.250

· 1

100 VA

120 Vac

6.250

·

40 VA

120 Vac

3.250

·

40 VA

120 Vac

3.250

· 1

40 VA

120 Vac

4.500

· 1

40 VA

120 Vac

4.500

· 1

40 VA

120 Vac

4.500

·

40 VA

120 Vac

4.500

· 1

40 VA

120 Vac

4.500

·

75 VA 480/277/240/208/120 Vac 4.500

·

75 VA 480/277/240/208/120 Vac 4.500

·

75 VA 480/277/240/208/120 Vac 4.500

·

75 VA 480/277/240/208/120 Vac 4.500

· 1

100 VA

120 Vac

4.500

· 1

100 VA

120 Vac

4.500

· 1

100 VA

120 Vac

4.500

·

100 VA

120 Vac

4.500

· 1

100 VA

120 Vac

4.500

· 75 VA, 75 VA 480/277/240/208/120 Vac 4.500

· 75 VA, 75 VA 480/277/240/208/120 Vac 4.500

· 75 VA, 75 VA 480/277/240/208/120 Vac 4.500

· 75 VA, 75 VA 480/277/240/208/120 Vac 4.500

· 1 100 VA, 100 VA

120 Vac

4.500

· 1 100 VA, 100 VA

120 Vac

4.500

· 1 100 VA, 100 VA

120 Vac

4.500

· 1 100 VA, 100 VA

120 Vac

4.500

WIDTH 5.250 5.250 5.620 5.620 2.750 2.750 5.438 5.438 5.438 5.438 5.438 5.438 5.438 5.438 5.438 5.438 5.438 5.438 5.438 5.438 8.625 8.625 8.625 8.625 8.625 8.625 8.625 8.625

DEPTH 3.750 3.750 4.250 4.250 2.000 2.000 4.500 4.500 4.500 4.500 4.500 4.500 4.500 4.500 4.500 4.500 4.500 4.500 4.500 4.500 4.500 4.500 4.500 4.500 4.500 4.500 4.500 4.500

Product Selection Guide. For full product information, see our website.

AUX

120 VAC OUTPUT MAIN BREAKER ON

OUTLETS WIRE INPUT POWER *

·

· 10 A Switch/Breaker

SECONDARY CONFIGURATION
Ext. Terminal Strip

EXTENSION HOUSING STYLE / CORD TRACK MOUNT
Panel Mount

SHIPPING WEIGHT
3.340 lb.

·

· 10 A Switch/Breaker Ext. Terminal Strip

·

· 10 A Switch/Breaker Ext. Terminal Strip

Panel Mount 4.710 lb. Enclosed 5.727 lb.

·

· 10 A Switch/Breaker Ext. Terminal Strip

Enclosed 7.075 lb.

Terminal Strip

MT212-4 included 1.636 lb.

Terminal Strip

MT212-4 included 1.790 lb.

·

Ext. Terminal Strip

Enclosed 4.013 lb.

·

Internal Wires

Enclosed 4.020 lb.

·

· 10 A Switch/Breaker Ext. Terminal Strip

·

· 10 A Switch/Breaker Ext. Terminal Strip ·

Enclosed Enclosed

4.195 lb. 4.513 lb.

·

· 10 A Switch/Breaker Internal Wires

·

Ext. Terminal Strip

Enclosed Enclosed

4.140 lb. 5.386 lb.

·

Internal Wires

Enclosed 5.160 lb.

·

· 10 A Switch/Breaker Ext. Terminal Strip

Enclosed 5.433 lb.

·

· 10 A Switch/Breaker Internal Wires

Enclosed 5.473 lb.

·

Ext. Terminal Strip

Enclosed 5.352 lb.

·

Internal Wires

Enclosed 5.120 lb.

·

· 10 A Switch/Breaker Ext. Terminal Strip

·

· 10 A Switch/Breaker Ext. Terminal Strip ·

Enclosed Enclosed

5.480 lb. 5.240 lb.

·

· 10 A Switch/Breaker Internal Wires

·

Ext. Terminal Strip

Enclosed Enclosed

5.487 lb. 9.376 lb.

·

Internal Wires

Enclosed 9.440 lb.

·

· 10 A Switch/Breaker Ext. Terminal Strip

Enclosed 9.280 lb.

·

· 10 A Switch/Breaker Internal Wires

Enclosed 9.330 lb.

·

Ext. Terminal Strip

Enclosed 9.227 lb.

·

Internal Wires

Enclosed 9.395 lb.

·

· 10 A Switch/Breaker Ext. Terminal Strip

·

· 10 A Switch/Breaker Internal Wires

Enclosed Enclosed

9.320 lb. 9.440 lb.

AC POWER SUPPLIES: 200-500 VA

MODEL # PSH500A PSH300A PSH200A PSMN500A PSMN300A PSMN200A
PSH500A-LVC

TRANSFORMER

INPUT POWER

· 500 VA (five 100 VA Outputs) 480/277/240/120 Vac

· 300 VA (three 100 VA Outputs) 480/277/240/120 Vac

· 200 VA (five 40 VA Outputs) 480/347/277/240/120 Vac

· 500 VA (five 100 VA Outputs) 480/277/240/120 Vac

· 300 VA (three 100 VA Outputs) 480/277/240/120 Vac

· 200 VA (five 40 VA Outputs) 480/347/277/240/120 Vac

· 500 VA (five 100 VA Outputs) 480/277/240/120 Vac

PSH300A-LVC · 300 VA (three 100 VA Outputs) 480/277/240/120 Vac

PSH200A-LVC · 200 VA (five 40 VA Outputs) 480/347/277/240/120 Vac

PSH500AB10-LVC · 500 VA (five 100 VA Outputs)

120 Vac

PSH300AB10-LVC · 300 VA (three 100 VA Outputs)

120 Vac

PSH200AB10-LVC · 200 VA (five 40 VA Outputs)

120 Vac

HEIGHT
12.125 12.125 12.125 11.330 11.330 11.330 12.125
12.125
12.125
12.125
12.125
12.125

Product Selection Guide. For full product information, see our website.

WIDTH

DEPTH

SECONDARY

120 VAC BREAKER PER CONFIGURA-

OUTLET# OUTPUT

TION

HOUSING STYLE / SUB-PANEL

SHIPPING WEIGHT

12.125 6.000

5 x 4 Amp Terminals

Enclosed

32.368 lb.

12.125 6.000

3 x 4 Amp Terminals

Enclosed

20.922 lb.

12.125 6.000

5 x 2 Amp Terminals

Enclosed

19.440 lb.

11.400 5.000

5 x 4 Amp Terminals Sub-panel Mount 21.126 lb.

11.400 4.500

3 x 4 Amp Terminals Sub-panel Mount 11.300 lb.

11.400 5.000

5 x 2 Amp Terminals Sub-panel Mount 10.540 lb.

12.125 6.000

5 x 4 Amp

Terminals

Enclosed with Low Voltage Compartment

33.080 lb.

12.125 6.000

3 x 4 Amp

Terminals

Enclosed with Low Voltage Compartment

21.500 lb.

12.125 6.000

5 x 2 Amp

Terminals

Enclosed with Low Voltage Compartment

20.300 lb.

12.125 6.000 ·

5 x 4 Amp

Terminals

Enclosed with Low Voltage Compartment

33.280 lb.

12.125 6.000 ·

3 x 4 Amp

Terminals

Enclosed with Low Voltage Compartment

21.620 lb.

12.125 6.000 ·

5 x 2 Amp

Terminals

Enclosed with Low Voltage Compartment

20.916 lb.

= Class 2 (UL Approved UL5085-3) : UL916 Energy Management USA & Canada

1 = Class 2 (UL Approved UL5085-3) : UL916 Energy Management USA & Canada : UL508 Industrial Control Equipment

* = Kills power to entire unit: Outlets, Aux. Output, & Transformer; Total Combined Output 9A

# = Convenience outlet has 4 Amp Breaker

For full product information, see data sheets on website. Shipping weights are approximate and may change due to packaging options.

(800) 888-5538 | www.functionaldevices.com

57

AC & DC POWER SUPPLIES

PREPACKAGED AC POWER SUPPLY KITS

Product Selection Guide. For full product information, see our website.

MODEL # CTRL-PS

TRANSFORMER(S)
40 VA

INPUT POWER
120 Vac

HEIGHT 14.500

WIDTH 7.700

AUX 120 VAC OUTPUT ON/OFF DEPTH OUTLETS WIRE SWITCH

3.900

·

MAIN BREAKER ON INPUT POWER *

SECONDARY CONFIGURATION

METAL HOUSING
MH1000

SUB-PANEL / TRACK MOUNT
MT212-4 included

SHIPPING WEIGHT
9.220 lb.

MHP3903100AB10

100 VA 120 Vac 12.500 24.500 6.500 ·

·

·

10 A Switch/Breaker Ext. Terminal Strip MH3900

SP3803S (Polymetal)

31.000 lb.

MHP3904100AB10

100 VA 120 Vac 12.500 24.500 6.500 ·

·

·

10 A Switch/Breaker Ext. Terminal Strip

MH3900

SP3804S (Perforated)

31.000 lb.

MHP4604100AB10

100 VA 120 Vac 16.150 20.000 6.720 ·

·

·

10 A Switch/Breaker Ext. Terminal Strip

MH4600

SP4604 (Perforated)

31.000 lb.

MHP3903100A100AB10 100 VA, 100 VA 120 Vac 12.500 24.500 6.500 ·

·

·

10 A Switch/Breaker Ext. Terminal Strip MH3900

SP3803S (Polymetal)

33.000 lb.

MHP3904100A100AB10 100 VA, 100 VA 120 Vac 12.500 24.500 6.500 ·

·

·

10 A Switch/Breaker Ext. Terminal Strip

MH3900

SP3804S (Perforated)

33.000 lb.

MHP4604100A100AB10 100 VA, 100 VA 120 Vac 16.150 20.000 6.720 ·

·

·

10 A Switch/Breaker Ext. Terminal Strip

MH4600

SP4604 (Perforated)

33.000 lb.

DC POWER SUPPLIES

MODEL # PSP24DA

VOLTAGE INPUT

·

24 Vac

PSH24DWB10

120 Vac

PSH100A24DWB10

120 Vac

PSMN24DA

·

24 Vac

PSMN24DAS

·

24 Vac

PSM20A12DAS

·

24 Vac

PSM24A24DAS

·

24 Vac

PSM19A24DAS

·

120 Vac

PSMN40A24DS

·

120 Vac

VOLTAGE OUTPUT Adjustable 1.5-28 Vdc ; Non-Isolated
Fixed 24 Vdc ; Isolated Fixed 24 Vdc ; Isolated 100 VA, 24 Vac Adjustable 1.5-28 Vdc ; Non-Isolated Adjustable 1.5-28 Vdc ; Non-Isolated
Adjustable 1.5-14 Vdc ; Isolated Adjustable 1.5-28 Vdc ; Isolated Adjustable 1.5-28 Vdc ; Isolated
Fixed 24 Vdc ; Isolated

Product Selection Guide. For full product information, see our website.

OUTPUT ON/OFF

HOUSING STYLE / SHIPPING

CURRENT SWITCH HEIGHT WIDTH DEPTH TRACK MOUNT WEIGHT

300 mA

2.300 3.200 1.800

Enclosed

0.363 lb.

2.5 Amp

·

4.500 5.438 4.500

Enclosed

3.000 lb.

2.5 Amp

·

4.500 8.625 4.500

Enclosed

6.987 lb.

300 mA

1.750 2.750 1.500 MT212-2 included 0.169 lb.

300 mA

·

1.750 2.750 1.500 MT212-2 included 0.187 lb.

300 mA

·

4.000 2.750 1.625 MT212-4 included 1.169 lb.

300 mA

·

4.000 2.750 1.625 MT212-4 included 1.198 lb.

300 mA

·

4.000 2.750 1.625 MT212-4 included 1.162 lb.

1 Amp

·

5.000 2.750 2.500 MT212-6 included 1.890 lb.

POWER SUPPLIES

= Class 2 (UL Approved UL5085-3) : UL916 Energy Management USA & Canada

* = Kills power to entire unit: Outlets, Aux. Output, & Transformer; Total Combined Output 9A

For full product information, see data sheets on website. Shipping weights are approximate and may change due to packaging options.

58

Functional Devices, Inc. | American Made. American Owned.

NOTES

POWER SUPPLIES

(800) 888-5538 | www.functionaldevices.com

59

NOTES

POWER SUPPLIES

60

Functional Devices, Inc. | American Made. American Owned.

TRANSFORMERS

TR50VA001US

TRANSFORMERS

TR40VA002US

TR100VA009US

US MANUFACTURED TRANSFORMERS

· 40 VA through 96 VA · Single and dual hub · Foot or hub mountable · Circuit breaker models

· Class 2 UL Listed · 24 Vac secondary · Single and multi-tap primaries

US MANUFACTURED TRANSFORMERS: 40-96 VA

MODEL #

MADE IN USA

OVER

VA

CURRENT CLASS

RATING STYLE PROTECTION 2

TR40VA001US · · 40VA 1

Inherent

·

PRIMARY VOLTAGE
(VAC)
120

SEC. VOLTAGE FOOT
(VAC) MOUNT

HUBS

SHIPPING

L

W

H

A

B

C WEIGHT

24

· 1 Threaded 2.380" 2.200" 2.930" 1.720" 1.750" .980" 1.770 lb.

TR40VA002US · · 40VA 4

Inherent

·

120

24

· 2 Threaded 2.380 2.200 2.920 1.720 1.750 .980" 1.780 lb.

TR50VA001US · · 50VA 1

Fuse

·

120

24

· 1 Threaded 2.750" 2.200" 2.910" 2.060" 1.750" 1.330" 2.200 lb.

TR50VA005US · · 50VA 2 Circuit Brkr. ·

120

24

· 1 Threaded 3.270 2.525 3.250 2.210 2.000 1.130 2.668 lb.

TR50VA022US · · 50VA 5 Circuit Brkr. · 480/277/240/208/120 24

· 2 Threaded 3.260 2.525 3.290 2.190 2.000 1.120 2.760 lb.

TR100VA001US · · 96VA 2 Circuit Brkr. ·

120

24

· 1 Threaded 3.780 2.500 3.290 2.740 2.000 1.630 3.570 lb.

TR100VA002US · · 96VA 5 Circuit Brkr. ·

120

24

· 2 Threaded 3.750 2.500 3.290 2.690 2.000 1.600 3.600 lb.

TR100VA009US · · 96VA 5 Circuit Brkr. · 480/277/240/208/120 24

· 2 Threaded 3.500 2.500 3.250 2.720 2.000 1.630 3.732 lb.

For more transformers, see page 64.

= UL Listed : UL5085-2 or UL5085-3 ; USA & Canada

For full product information, see data sheets on website. Shipping weights are approximate and may change due to packaging options.

62

Functional Devices, Inc. | American Made. American Owned.

STYLE 1
Single Hub & Foot Mount
STYLE 3
Single Hub & Foot Mount with Circuit Breaker
STYLE 5
Dual Hub & Foot Mount with Circuit Breaker
STYLE 7
Two Bottom Openings & Foot Mount
STYLE 9
Single Hub & Dual Terminal
Secondary
STYLE 11
Two Side Openings & Foot Mount
STYLE 13
90º Conduit Connector & Mounting Plate Opening

STYLE 2
Single Hub & Foot Mount with Circuit Breaker
STYLE 4
Dual Hub & Foot Mount
STYLE 6
Single Hub & Side Opening with Circuit Breaker
STYLE 8
Single Hub, Side Opening & Foot Mount
STYLE 10
Two End-Bell Openings, & Foot Mount
with Circuit Breaker
STYLE 12
Dual Hub & Foot Mount with Circuit Breaker

TRANSFORMERS

Transformers may be foot mount, hub mount, or both. Transformers with the hub mount option will have either a single threaded hub or dual threaded hubs. Several transformers are provided with a circuit breaker and many are Class 2. Pigtail wires are standard on most models and are typically 8.00 in length. 1
All transformers utilize split-bobbin construction, making them inherently isolated. Custom transformers are also available (contact factory).
Frequency: 50/60 Hz Hub Style: .5 NPT Hub Wire Length: 8 Typical with .5 Strip 1 Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) MTBF: 100,000 Hours @ 77° F Construction: Split-Bobbin Approvals: CE approved, RoHS. See charts for UL approvals.
1 = TR40VA022 = 8 Primary, 30 Secondary, with .5 Strip TR50VA019 = 28 Typical with .5 Strip TR100VA002-20 = 8 Primary, 20 Secondary, with .5 Strip
Instructions inside product box include wire colors/voltages.
Additional information on voltage and wire colors is available on individual data sheets on website.
Dimensions: See charts.
C

B

A

L

W

1 .50" 8.00"

1
H
8.00" .50"

D

(800) 888-5538 | www.functionaldevices.com

63

TRANSFORMERS

TRANSFORMERS

TRANSFORMERS

TRANSFORMERS: 20-375 VA

MODEL #

OVER

VA

CURRENT CLASS

RATING STYLE PROTECTION 2

TR20VA001

· 20VA

1

Inherent

·

TR20VA002

· 20VA 4

Inherent

·

TR20VA003

· 20VA

1

Inherent

TR20VA004

· 20VA 4

Inherent

·

TR20VA007

· 20VA 1

Inherent

·

TR40VA001

· 40VA

1

Inherent

·

TR40VA002

· 40VA 4

Inherent

·

TR40VA003

· 40VA

1

Inherent

·

TR40VA004

· 40VA 4

Inherent

·

TR40VA013

· 40VA 2

Circuit Brkr.

TR40VA015

· 40VA 1 Internal Thermal ·

TR40VA022 # · 40VA 4

Inherent

·

TR40VA040 ^ · 40VA 9 Internal Thermal ·

TR50VA001

· 50VA 1

Fuse

·

TR50VA002

· 50VA 4

Fuse

·

TR50VA003

· 50VA 4

Fuse

·

TR50VA004

· 50VA 5

Circuit Brkr.

·

TR50VA005

· 50VA 2

Circuit Brkr.

·

TR50VA006

· 50VA 1

Fuse

·

TR50VA007

· 50VA 4

Fuse

·

TR50VA008

· 50VA 5

Circuit Brkr.

TR50VA009

· 50VA 5

Circuit Brkr.

·

TR50VA014

· 50VA 2

Circuit Brkr.

·

TR50VA015

· 50VA 2

Circuit Brkr.

·

TR50VA016

· 50VA 2

Circuit Brkr.

·

TR50VA017

· 50VA 2

Circuit Brkr.

·

PRIMARY VOLTAGE
(VAC) 120 208 24 277/240/208/120 277 120 120 24 277/240/208/120 480/277/240/208 240/208/120 120 240/208/120 120 120 240/208 480/277/240/120 120 277 277 480/277/240/208 240/208/120 277 480/277/240/208/120 240/208/120 480/277/208

SEC. VOLTAGE
(VAC) 24 24 24 24 24 24 24 24 24 120 24 24 24 24 24 24 24 24 24 24 120 24 24 24 24 24

TR50VA018

· 50VA 13

480/277/240/208

120

TR50VA019 #

50VA 11

TR75VA001

· 75VA 2

TR75VA002

· 75VA 5

TR75VA003

· 75VA 2

TR75VA004

· 75VA 6

TR75VA005

· 75VA 2

TR75VA007

· 75VA

5

TR100VA001 · 100VA 2

TR100VA002 · 100VA 5

TR100VA002-20 # · 100VA 5

TR100VA004 · 100VA 5

TR100VA005 · 100VA 2

TR100VA008 · 100VA 5

TR100VA009 · 100VA 5

TR100VA015 · 100VA 2

TR150VA001 · 150VA 3

TR150VA002 · 150VA 5

TR150VA008 · 150VA 12

TR175VA001 · 175VA 7

TR175VA002 · 175VA 4

TR175VA003 · 175VA 1

TR240VA001
TR300VA002 TR375VA001

· 240VA 8
300VA 10 · 375VA 7

Inherent Circuit Brkr. Circuit Brkr. Circuit Brkr.
Circuit Brkr.
Circuit Brkr. Circuit Brkr. Circuit Brkr. Circuit Brkr. Circuit Brkr. Circuit Brkr. Circuit Brkr. Circuit Brkr. Circuit Brkr. Circuit Brkr. Circuit Brkr. Circuit Brkr. Circuit Brkr.
Thermal Fuse on Primary
Circuit Brkr.

·

277/120

24

·

120

24

·

120

24

·

277

24

·

480/240/208/120

24

·

480/240/208/120

24

·

480/240/208/120

24

·

120

24

·

120

24

·

120

24

·

480/277/240/120

24

·

480/277/240/120

24

480/277/240/208

120

· 480/277/240/208/120 24

· 480/277/240/208/120 24

120

24

120

24

480/277/240/208

120

240/208

24

120

24

120

24

120

24

480/240/208/120

24

120

24

FOOT MOUNT
· · · · · · · · · · · · · · · · · · · · · · · · · ·
· · · ·
·
· · · · · · · · · · · · · · ·

HUBS 1 Threaded 2 Threaded 1 Threaded 2 Threaded 1 Threaded 1 Threaded 2 Threaded 1 Threaded 2 Threaded 1 Threaded 1 Threaded 2 Threaded 1 Threaded 1 Threaded 2 Threaded 2 Threaded 2 Threaded 1 Threaded 1 Threaded 2 Threaded 2 Threaded 2 Threaded 1 Threaded 1 Threaded 1 Threaded 1 Threaded 1, 90° Conduit Connector, 1 Mounting Plate Opening 2 Side Openings 1 Threaded 2 Threaded 1 Threaded 1 Threaded 1 Side Opening 1 Threaded 2 Threaded 1 Threaded 2 Threaded 2 Threaded 2 Threaded 1 Threaded 2 Threaded 2 Threaded 1 Threaded 1 Threaded 2 Threaded 2 Threaded 2 Bottom Openings 2 Threaded

L 2.226" 2.296" 2.272" 2.310" 2.302" 2.607" 2.634" 2.653" 2.631" 3.267" 2.628" 2.660" 2.728" 2.677" 2.696" 2.695" 3.475" 3.489" 2.763" 2.715" 3.440" 3.412" 3.479" 3.405" 3.345" 3.470"
2.470" 3.743" 3.890" 3.875"
3.802"
3.880" 3.883" 4.085" 4.077" 3.973" 4.173" 4.258" 4.220" 4.270" 4.270" 3.650" 3.620" 4.283" 3.801" 3.800"

W 1.877" 1.902" 1.900" 1.890" 1.895" 2.169" 2.177" 2.171" 2.177" 2.505" 2.175" 2.172" 2.171" 2.178" 2.181" 2.181" 2.513" 2.515" 2.182" 2.173" 2.510" 2.504" 2.509" 2.517" 2.510" 2.520"

H 2.595" 2.616" 2.628" 2.625" 2.607" 2.906" 2.886" 2.882" 2.882" 3.000" 2.907" 2.891" 2.890" 2.879" 2.908" 2.899" 3.014" 3.008" 2.898" 2.886" 3.012" 3.014" 3.009" 3.013" 3.028" 3.031"

A 1.612" 1.604" 1.635" 1.540" 1.608" 2.020" 2.007" 2.033" 1.998" 1.699" 2.040" 1.980" 1.995" 2.109" 2.053" 2.082" 1.858" 1.870" 2.135" 2.148" 1.932" 1.864" 1.873" 1.875" 1.842" 1.880"

SHIPPING B C D WEIGHT 1.619" 1.013" 2.125" 1.331 lb. 1.665" 1.020" 2.114" 1.363 lb. 1.686" 1.023" 2.153" 1.370 lb. 1.625" 1.000" 2.100" 1.422 lb. 1.685" 1.019" 2.107" 1.337 lb. 1.786" 1.204" 2.545" 1.952 lb. 1.775" 1.206" 2.564" 1.980 lb. 1.779" 1.185" 2.580" 2.018 lb. 1.774" 1.189" 2.553" 2.127 lb. 1.986" 1.114" 2.325" 2.588 lb. 1.780" 1.188" 2.590" 2.331 lb. 1.786" 1.201" 2.526" 2.070 lb. 1.792" 1.215" 2.550" 2.315 lb. 1.793" 1.253" 2.664" 2.132 lb. 1.788" 1.278" 2.614" 2.186 lb. 1.778" 1.294" 2.646" 2.219 lb. 1.970" 1.291" 2.490" 2.840 lb. 1.971" 1.294" 2.463" 2.730 lb. 1.790" 1.322" 2.698" 2.164 lb. 1.784" 1.276" 2.661" 2.227 lb. 1.945" 1.346" 2.523" 2.866 lb. 1.961" 1.313" 2.485" 2.842 lb. 1.965" 1.285" 2.480" 2.743 lb. 1.985" 1.316" 2.484" 2.844 lb. 1.978" 1.325" 2.454" 2.804 lb. 1.872" 1.292" 2.460" 2.812 lb.

Refer to data sheet on website.

3.276 lb.

2.170" 2.506" 2.508" 2.507"

2.896" 3.016" 3.013" 3.037"

1.850" 2.256" 2.290" 2.269"

1.740" 1.130" 2.512" 1.974" 1.711" 2.873" 1.952" 1.701" 2.882" 1.978" 1.684" 2.860"

2.026 lb. 3.558 lb. 3.567 lb. 3.576 lb.

2.515" 3.050" 2.244" 1.990" 1.665" 2.850" 3.726 lb.

2.515" 2.504" 2.515" 2.504" 2.518" 2.523" 2.510" 2.525" 2.500" 2.500" 3.800" 3.785" 3.786" 3.790" 3.790"

3.030" 3.034" 3.030" 3.023" 3.033" 3.041" 3.030" 3.022" 4.060" 4.060" 3.183" 3.160" 3.161" 3.163" 3.189"

2.270" 2.287" 2.486" 2.470" 2.486" 2.647" 2.670" 2.690" 2.750" 2.699" 2.560" 2.568" 3.211" 3.264" 3.220"

1.975" 1.700" 2.854" 1.981" 1.708" 2.887" 1.975" 1.900" 3.082" 1.975" 1.888" 3.095" 1.865" 1.924" 3.060" 1.976" 2.086" 3.268" 1.968" 2.065" 3.260" 1.970" 2.082" 3.272" 1.975" 2.000" 2.252" 2.030" 2.065" 2.252" 3.150" 1.438" 3.514" 3.147" 1.456" 3.511" 3.260" 2.116" 4.177" 3.141" 2.151" 4.197" 3.150" 2.100" 4.180"

3.724 lb. 3.727 lb. 3.984 lb. 4.010 lb. 4.082 lb. 4.524 lb. 4.496 lb. 4.313 lb. 4.524 lb. 4.524 lb. 5.073 lb. 5.157 lb. 7.158 lb. 6.980 lb. 7.047 lb.

·

1 Threaded

4.030" 3.786" 3.161" 3.189" 3.155" 2.127" 4.153" 6.935 lb.

·

1 Threaded

3.957" 3.750" 4.530" 3.350" 3.180" 1.932" 4.025" 8.470 lb.

1 Bottom Opening

·

2 End-Bell Openings 5.499" 3.750" 4.500" 3.859" 3.187" 2.526" 4.526" 11.568 lb.

·

2 Bottom Openings 4.592" 3.747" 4.504" 3.933" 3.181" 2.516" 4.630" 11.120 lb.

= UL Listed : UL5085-2 or UL5085-3 ; USA & Canada

= UL Component Recognized : UL5085-2 or UL5085-3 ; USA & Canada # = Refer to website for more wire length information ^ = Dual Terminal Secondary

For full product information, see data sheets on website. Shipping weights are approximate and may change due to packaging options.

64

Functional Devices, Inc. | American Made. American Owned.

NOTES

TRANSFORMERS

(800) 888-5538 | www.functionaldevices.com

65

NOTES

TRANSFORMERS

66

Functional Devices, Inc. | American Made. American Owned.

POWER CONTROL

PSH600-UPS-STAT

POWER CONTROL

PSPT2RB4

PSM2RB10

PSMS1

PSMN24SB10

POWER CONTROL

SIB05S-RD

Enclosed Power Control Centers
· Two 120 Vac grounded convenience outlets · 4 or 10 Amp switch / circuit breaker · Outlets can be continuously powered or controlled
by the switch / circuit breaker. · True override switch on load side of relay · Auxiliary outputs are provided for convenient
control panel installations.
Track Mount Circuit Breaker Switches
· Track mount circuit breaker switches provide a convenient addition to control panels.
· Circuits can be low voltage (24 Vac) or line voltage (120 Vac).
Prepackaged Switches
· Standard configurations to provide simple switching schemes.
· Labels can be ordered with custom content to fit your project.

UPS Power Supplies
· Perfect for applications in hospitals, laboratories and research & surgery centers
· Keep your critical controller powered on during a loss of normal utility power with the ability to hardwire line voltage to the provided UPS, in addition to hardwiring the UPS to the final load.
· Kits include: 600 or 850 VA commercial UPS, NEMA 1 metal enclosure, and interface board
· BACnet® compatible model is BTL Certified and includes six objects: Line or UPS power, UPS percent load, VA load, UPS battery capacity, USB connection, and remaining battery time.
· Cords tuck inside enclosure for clean & neat use of a UPS.
· 600 VA UPS is hot-swappable.
· 120 Vac convenience outlet(s) provided
· 10 Amp circuit breaker / switch can be used to test functionality of UPS.
· Switch controls line voltage

68

Functional Devices, Inc. | American Made. American Owned.

POWER CONTROL

ENCLOSED POWER CONTROL CENTERS

MODEL # PSPT2RB4

120 VAC

OUTLETS

·

2

SWITCH On / Off

CIRCUIT BREAKER 4 Amp

PSPW2RB4

·

2

On / Off

4 Amp

PSPT2RB10

·

2

On / Off

10 Amp

PSPW2RB10

·

2

On / Off

10 Amp

Product Selection Guide. For full product information, see our website.

HEIGHT 4.000 4.000 4.000 4.000

WIDTH 4.000 4.000 4.000 4.000

DEPTH 1.800 1.800 1.800 1.800

WIRES
· ·

TERMINALS
·
·

SHIPPING WEIGHT 0.608 lb. 0.641 lb. 0.616 lb. 0.660 lb.

TRACK MOUNT CIRCUIT BREAKER SWITCHES

MODEL # PSMN01SB4 PSMN01SB10 PSMN24SB4 PSMN24SB10

POWER INPUT

·

120 Vac

·

120 Vac

·

24 Vac

·

24 Vac

SWITCH On / Off On / Off On / Off On / Off

LED CIRCUIT BREAKER

·

4 Amp

·

10 Amp

·

4 Amp

·

10 Amp

Product Selection Guide. For full product information, see our website.

HEIGHT 2.750 2.750 2.750 2.750

WIDTH 1.350 1.350 1.350 1.350

DEPTH 2.061 2.061 2.061 2.061

TRACK MOUNT MT212-2 included MT212-2 included MT212-2 included MT212-2 included

SHIPPING WEIGHT 0.166 lb. 0.180 lb. 0.168 lb. 0.162 lb.

PREPACKAGED SWITCHES

MODEL # PSMS1

RELAY CONTACTS
· 1 SPST

SWITCH Maintained 3 Position

SIB02S

· 1 SPDT

Maintained 3 Position

SIB04S

·

1 SPDT

Maintained 2 Position (On / On)

SIB05S

·

1 SPST Maintained 2 Position (On / Off)

SIBLS

· 1 SPDT

Maintained 3 Position

SWITCH RATING 5 Amp @ 30 Vac/dc 20 Amp @ 277 Vac 20 Amp @ 277 Vac 20 Amp @ 277 Vac 5 Amp @ 30 Vac/dc

Product Selection Guide. For full product information, see our website.

HEIGHT WIDTH DEPTH ENCLOSED

TRACK MOUNT

SHIPPING WEIGHT

1.275 4.000 1.750

MT4 Series sold separately 0.107 lb.

1.700 2.800 1.500

·

0.290 lb.

1.700 2.800 1.500

·

0.292 lb.

1.700 2.800 1.500

·

0.253 lb.

1.700 2.800 1.500

·

0.273 lb.

UPS POWER SUPPLIES

MODEL # PSH600-UPS (Kit)

CIRCUIT 120 VAC

STATUS UPS BREAKER OUTLET(S)

600 VA ·

·

PSH2RB10

·

·

·

PSM2RB10

·

·

·

PSH600-UPS-STAT (Kit)

· 600 VA ·

·

PSH2C2RB10

··

·

·

PSMN2C2RB10

··

·

·

PSH850-UPS-STAT (Kit)

· 850 VA ·

·

PSH2C2RB10-L

··

·

·

PSH600-UPS-BC (Kit)

· 600 VA ·

·

Product Selection Guide. For full product information, see our website.

COMPATIBLE

KIT N/A PSH600-UPS

ENCLOSED
· ·

TRACK MOUNT

SHIPPING HEIGHT WIDTH DEPTH WEIGHT 12.000 14.000 6.000 23.180 lb.
12.000 14.000 6.000 12.560 lb.

PSH600-UPS

N/A

·

PSH600-UPS-STAT

·

MT4-4N included

4.000 12.000 12.000

3.250 1.750 16.000 6.000 16.000 6.000

0.880 lb. 24.100 lb. 14.060 lb.

PSH600-UPS-STAT

MT212-6N included 2.750 6.655 1.750 0.984 lb.

N/A

·

14.000 16.000 6.000 34.800 lb.

PSH850-UPS-STAT

·

14.000 16.000 6.000 16.290 lb.

·

N/A

·

12.000 16.000 6.000 24.262 lb.

POWER CONTROL

= UL Listed : UL916 Energy Management; UL Listed Canada
For full product information, see data sheets on website. Shipping weights are approximate and may change due to packaging options.

(800) 888-5538 | www.functionaldevices.com

69

NOTES

POWER CONTROL

70

Functional Devices, Inc. | American Made. American Owned.

WIRELESS DEVICES

HVAC & Lighting Energy Management

Gateway/BMS
Key Card Switch
controls access to a room and turns on heating and lighting
when entering a room

Position Sensors
set back HVAC when windows are open

Occupancy Sensor
adjusts temperature and turns off lights when a
room is not in use
Batteryless Wireless Switches
control lighting

WIRELESS DEVICES

YOUR PAYBACK/ROI
· 70% COST SAVINGS IN RETROFITS · 40% ENERGY SAVINGS · UNLIMITED FLEXIBILITY
902 MHz · Maintenance-free Flexibility of applications · Time saving Cost savings in installation, renovation, and energy usage

Many hotels keep their rooms at a comfortable temperature for the duration of their guests' stays ­ whether the guests are in or out of their room. With guest comfort as a priority, hotels and motels typically use almost 40 percent of their electricity on heating and cooling rooms, even though studies show that most sold rooms are unoccupied for 12 or more hours a day. Used correctly, the right controls could offer significant energy savings without compromising the comfort of guests.

72

Information from: EnOcean® Alliance & ENERGY STAR Building Upgrade Manual Functional Devices, Inc. | American Made. American Owned.

ENOCEAN® ENABLED WIRELESS DEVICES

WIRELESS DEVICES

RIBW01B-EN3

RIBW01C-EN3

WDWS-EN3

WWS2-EN3

WKC-EN3

WVSCM-EN3

WVSWM-EN3

EnOcean® Enabled Wireless RIB® Relay Receivers & Transceivers work in conjunction with many 902 MHz EnOcean® enabled transmitters.
Wireless wall switches, occupancy sensors, thermostats, key card switches, and patio & door switches are all devices which can activate the RIB® Wireless Control Relays by using EnOcean's "energy harvesting" technology. Energy harvesting refers to the process by which energy is captured and stored, then used to transmit a wireless signal, which in turn is received by the RIB® Wireless Relay.

WIRELESS CONTROL RELAYS

Product Selection Guide. For full product information, see our website.

COIL VOLTAGE

CONTACT RATINGS

MODEL #

RELAY AC/DC AC CONTACTS RESISTIVE

MOTOR

REPEAT DRY CONTACT DIMMER HOUSING

SHIPPING

PILOT DUTY FUNCTION INPUT FUNCTION STYLE * FREQUENCY WEIGHT

RIBW01B-EN3 ·

120 1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac ·

·

B

902 MHz 0.660 lb.

RIBW208B-EN3 ·

208 1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac ·

·

B

902 MHz 0.658 lb.

RIBW240B-EN3 ·

240 1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac ·

·

B

902 MHz 0.660 lb.

RIBW277B-EN3 ·

277 1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac ·

·

B

902 MHz 0.657 lb.

RIBW24B-EN3 · 24

1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac ·

·

B

902 MHz 0.648 lb.

RIBW21BAO-EN3 ·

120-277 1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac ·

·

B

902 MHz 0.660 lb.

RIBW01C-EN3 ·

120 1 SPST 5 A Ballast @ 120/277 Vac; 5 A Elec. Ballast @ 120 Vac ·

Ballast size 902 MHz 0.318 lb.

RIBW02C-EN3 ·

208-277 1 SPST 5 A Ballast @ 120/277 Vac; 5 A Elec. Ballast @ 120 Vac ·

Ballast size 902 MHz 0.280 lb.

WIRELESS TRANSMITTERS

MODEL # WWS2-EN3 WDWS-EN3 WKC-EN3 WVSCM-EN3 WVSWM-EN3

DESCRIPTION Wall switch with barrier & cover plate Door and window switch Keycard switch Occupancy / vacancy sensor, ceiling mount Occupancy / vacancy sensor, wall mount

Product Selection Guide. For full product information, see our website.

POWER INPUT

ENOCEAN® ENERGY HARVESTING

FREQUENCY

COLOR

SHIPPING WEIGHT

Self-Powered

·

902 MHz

White

0.288 lb.

Light-Powered

·

902 MHz

White

0.217 lb.

Self-Powered

·

902 MHz

White

0.360 lb.

Light-Powered

·

902 MHz

White

0.288 lb.

Light-Powered

·

902 MHz

White

0.288 lb.

= UL Listed : UL916 Energy Management ; USA & Canada

* = See Housing Guide on pages 86-87

For full product information, see data sheets on website. Shipping weights are approximate and may change due to packaging options.

(800) 888-5538 | www.functionaldevices.com

73

NOTES

WIRELESS DEVICES

74

Functional Devices, Inc. | American Made. American Owned.

ENCLOSURES

MH5503L

MH3803L

MH4404L

ENCLOSURES
Metal & Plastic Enclosures
· NEMA 1 or NEMA 4/4X rated · Various sizes available · Multiple knockouts on many models · Vertically and horizontally stackable · Available with perforated steel or polymetal
sub-panels or track mount · Several cover and door configurations · Grey finish · Blue housings available (consult factory) · Made in the USA · UL Listed

MH3300

MH1210

ENCLOSURES

76

Functional Devices, Inc. | American Made. American Owned.

ENCLOSURES

ENCLOSURES

MODEL #

PE6000

·

PE6010

·

PE6020

·

PE6000-N4 ·

PE6010-N4 ·

PE6020-N4 ·

MH1000

·

MH1010

·

MH1020

·

MH1200

·

MH1210

·

MH1220

·

MH2204-N4 ·

MH3100-M1 ·

MH3204-N4 ·

MH3300

·

MH3300K ·

MH3303

·

MH3304

·

MH3303K ·

MH3304K ·

MH3500

·

MH3510

·

MH3520

·

MH3800

·

MH3810

·

MH3820

·

MH3803S ·

MH3803L ·

MH3804S ·

MH3804L ·

MH4400

·

MH4403L ·

MH4404L ·

MH4604S ·

MH5500

·

MH5503L ·

MH5504L ·

MH5800

·

MH5803L ·

MH5804L ·

ENCLOSURE PE6000 PE6000 PE6000
PE6000-N4 PE6000-N4 PE6000-N4 MH1000 MH1000 MH1000 MH1200 MH1200 MH1200
MH3300 MH3300K MH3300 MH3300 MH3300K MH3300K MH3500 MH3500 MH3500 MH3800 MH3800 MH3800 MH3800 MH3800 MH3800 MH3800 MH4400 MH4400 MH4400 MH4600 MH5500 MH5500 MH5500 MH5800 MH5800 MH5800

HOUSING

TRACK

MATERIAL SUB-PANEL MOUNT

Plastic

Plastic

MT4-4

Plastic

MT212-6

Plastic

Plastic

MT4-4

Plastic

MT212-6

Metal

Metal

MT4-12

Metal

MT212-12

Metal

Metal

MT4-8

Metal

MT212-8

Metal 14 Gauge Steel

Metal

6 Threaded Studs

Metal 14 Gauge Steel

Metal

Metal

Metal

SP3303 #

Metal

SP3304 ^

Metal

SP3303 #

Metal

SP3304 ^

Metal

Metal

MT4-24

Metal

MT212-24

Metal

Metal

MT4-18

Metal

MT212-18

Metal

SP3803S #

Metal

SP3803L #

Metal

SP3804S ^

Metal

SP3804L ^

Metal

Metal

SP4403L #

Metal

SP4404L ^

Metal Perforated Steel

Metal

Metal

SP5503L #

Metal

SP5504L ^

Metal

Metal

SP5803L #

Metal

SP5804L ^

Product Selection Guide. For full product information, see our website.

NEMA RATING

COVER / DOOR

SHIPPING HEIGHT WIDTH DEPTH GAUGE WEIGHT

NEMA 1

Screw Down Cover

4.28 7.00 2.00

0.645 lb.

NEMA 1

Screw Down Cover

4.28 7.00 2.00

0.743 lb.

NEMA 1

Screw Down Cover

4.28 7.00 2.00

0.769 lb.

NEMA 4/4X

Screw Down Cover

4.28 7.00 2.00

0.656 lb.

NEMA 4/4X

Screw Down Cover

4.28 7.00 2.00

0.717 lb.

NEMA 4/4X

Screw Down Cover

4.28 7.00 2.00

0.769 lb.

NEMA 1

Screw Down Cover

14.50 7.70 3.90 18 5.940 lb.

NEMA 1

Screw Down Cover

14.50" 7.70" 3.90" 18 6.460 lb.

NEMA 1

Screw Down Cover

14.50" 7.70" 3.90" 18 6.000 lb.

NEMA 1

Screw Down Cover

8.30" 7.70" 3.90" 18 3.914 lb.

NEMA 1

Screw Down Cover

8.30" 7.70" 3.90" 18 4.060 lb.

NEMA 1

Screw Down Cover

8.30" 7.70" 3.90" 18 4.000 lb.

NEMA 4/4X

Hinge Key Latch Door

9.84 7.87 3.98 16 7.300 lb.

NEMA 1

Screw Down Cover

12.00 12.00 6.00 16 12.120 lb.

NEMA 4/4X

Hinge Key Latch Door

15.75 11.81 5.91

NEMA 1

Vertical Lift Screw Down Cover 12.50 12.50 7.00

NEMA 1

Vertical Lift Key Latch

12.50 12.50 7.00

NEMA 1

Vertical Lift Screw Down Cover 12.50 12.50 7.00

NEMA 1

Vertical Lift Screw Down Cover 12.50 12.50 7.00

NEMA 1

Vertical Lift Key Latch

12.50 12.50 7.00

NEMA 1

Vertical Lift Key Latch

12.50 12.50 7.00

NEMA 1 Reversible Hook Hinge Key Latch Door 24.50 10.25 3.90

NEMA 1 Reversible Hook Hinge Key Latch Door 24.50 10.25 3.90

NEMA 1 Reversible Hook Hinge Key Latch Door 24.50 10.25 3.90

NEMA 1 Reversible Hook Hinge Key Latch Door 24.50 12.50 6.50

NEMA 1 Reversible Hook Hinge Key Latch Door 24.50 12.50 6.50

NEMA 1 Reversible Hook Hinge Key Latch Door 24.50 12.50 6.50

NEMA 1 Reversible Hook Hinge Key Latch Door 24.50 12.50 6.50

NEMA 1 Reversible Hook Hinge Key Latch Door 24.50 12.50 6.50

NEMA 1 Reversible Hook Hinge Key Latch Door 24.50 12.50 6.50

NEMA 1 Reversible Hook Hinge Key Latch Door 24.50 12.50 6.50

NEMA 1

Full Hinge Key Latch Door

18.00 18.00 7.00

NEMA 1

Full Hinge Key Latch Door

18.00 18.00 7.00

NEMA 1

Full Hinge Key Latch Door

18.00 18.00 7.00

NEMA 1

Hinge Key Latch Door

20.00 16.15 6.72

NEMA 1

Full Hinge Key Latch Door

25.00 25.00 9.50

NEMA 1

Full Hinge Key Latch Door

25.00 25.00 9.50

NEMA 1

Full Hinge Key Latch Door

25.00 25.00 9.50

NEMA 1

Full Hinge Key Latch Door

36.00 25.00 9.50

NEMA 1

Full Hinge Key Latch Door

36.00 25.00 9.50

NEMA 1

Full Hinge Key Latch Door

36.00 25.00 9.50

16 17.070 lb. 18 10.540 lb. 18 10.680 lb. 18 11.740 lb. 18 12.100 lb. 18 11.920 lb. 18 12.520 lb. 18 11.100 lb. 18 11.700 lb. 18 11.540 lb. 18 16.580 lb. 18 16.860 lb. 18 16.800 lb. 18 18.190 lb. 18 18.510 lb. 18 19.630 lb. 18 19.890 lb. 16 22.760 lb. 16 24.866 lb. 16 26.260 lb. 14 31.000 lb. 14 50.700 lb. 14 55.780 lb. 14 59.960 lb. 14 68.480 lb. 14 74.200 lb. 14 79.530 lb.

MH3300 SERIES # Polymetal
11.33"H x 11.40"W
^ Perforated Steel 11.33"H x 11.40"W

MH3800 SERIES
# Polymetal Model S: 19.00"H x 11.75"W Model L: 23.00"H x 11.75"W
^ Perforated Steel Model S: 19.00"H x 11.75"W Model L: 23.00"H x 11.75"W

MH4400 SERIES # Polymetal
16.875"H x 15.75"W
^ Perforated Steel 16.875"H x 15.75"W

MH5500 SERIES # Polymetal
23.00"H x 22.50"W
^ Perforated Steel 23.00"H x 22.50"W

MH5800 SERIES # Polymetal
34.125"H x 22.50"W
^ Perforated Steel 34.125"H x 22.50"W

= UL Listed : UL916 Energy Management ; USA & Canada
For full product information, see data sheets on website. Shipping weights are approximate and may change due to packaging options.

(800) 888-5538 | www.functionaldevices.com

77

ENCLOSURES

NOTES

ENCLOSURES

78

Functional Devices, Inc. | American Made. American Owned.

ACCESSORIES

SP3303

MT4-6

ADIN35 & ADIN35ES

SP3804S

ACCESSORIES

ACCESSORIES
Sub-Panels
Two types of sub-panel material are available: polymetal and perforated steel. Both the polymetal and perforated steel sub-panels are Plenum Rated and designed to mount in "MH" metal housing models. The mounting holes are pre-drilled and ready to install. Sub-panels can be ordered pre-installed in your choice of "MH" enclosure. See general specifications of pre-assembled enclosure models on page 77.
Replacement Parts
Replacement parts are available for several products including remote sensors, socket relays, and more.

Mounting Supplies
Mounting options include plastic track for snap-mounting circuit boards. One style of track can be mounted to the back surface of any cabinet and is available in 4.00" or 2.75" widths. Another style of track, AdapTrack®, snaps onto any of the three most popular DIN rails. In turn, it can accomodate a 4.00" wide circuit board. Perforated DIN rail and end stops are also available.

80

Functional Devices, Inc. | American Made. American Owned.

ACCESSORIES

SUB-PANELS

MODEL # SP3303 SP3304 SP3803S SP3803L SP3804S SP3804L SP4403L SP4404L SP5503L SP5504L SP5803L SP5804L

USE WITH ENCLOSURE MH3300 or MH3300K MH3300 or MH3300K
MH3800 MH3800 MH3800 MH3800 MH4400 MH4400 MH5500 MH5500 MH5800 MH5800

MOUNTING SUPPLIES

MODEL #

MT212-2

·

MT212-4

·

MT212-6

·

MT212-8

·

MT212-12

·

MT212-18

·

MT212-24

·

MT212-48

·

MT4-2

·

MT4-4

·

MT4-6

·

MT4-8

·

MT4-10

·

MT4-12

·

MT4-18

·

MT4-24

·

MT4-48

·

AT4-2

·

AT4-6

·

AT4-12

·

AT4-24

·

AT4-48

·

ADIN35

WIDTH 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 35 mm

MATERIAL Polymetal Perforated Steel Polymetal Polymetal Perforated Steel Perforated Steel Polymetal Perforated Steel Polymetal Perforated Steel Polymetal Perforated Steel
LENGTH 2.00" 4.00" 6.00" 8.00" 12.00" 18.00" 24.00" 48.00" 2.00" 4.00" 6.00" 8.00" 10.00" 12.00" 18.00" 24.00" 48.00" 2.00" 6.00" 12.00" 24.00" 48.00"
7.5 mm

Product Selection Guide. For full product information, see our website.

HEIGHT 11.330 11.330 19.000 23.000 19.000 23.000 16.875 16.875 23.000 23.000 34.125 34.125

WIDTH 11.400 11.400 11.750 11.750 11.750 11.750 15.750 15.750 22.500 22.500 22.500 22.500

THICKNESS .130 .250 .130 .130 .250 .250 .130 .250 .130 .250 .130 .250

MOUNTING AREA 129.16 square inches 129.16 square inches 223.25 square inches 270.25 square inches 223.25 square inches 270.25 square inches 265.78 square inches 265.78 square inches 517.50 square inches 517.50 square inches 767.81 square inches 767.81 square inches

SHIPPING WEIGHT 0.847 lb. 1.662 lb. 1.705 lb. 2.140 lb. 2.940 lb. 3.520 lb. 2.100 lb. 3.415 lb. 3.940 lb. 6.560 lb. 5.875 lb. 9.720 lb.

Product Selection Guide. For full product information, see our website.

TRACK TYPE Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track
AdapTrack® for DIN rail AdapTrack® for DIN rail AdapTrack® for DIN rail AdapTrack® for DIN rail AdapTrack® for DIN rail
Perforated DIN rail

DISTANCE BETWEEN HOLE CENTERS 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center
3 Most Common for AT4 Series # 3 Most Common for AT4 Series # 3 Most Common for AT4 Series # 3 Most Common for AT4 Series # 3 Most Common for AT4 Series #
25 mm Center to Center

REPLACEMENT & MISCELLANEOUS PARTS

Product Selection Guide. For full product information, see our website.

MODEL # ADIN35ES APS53-TC AR24D ARL1C AWSTFM AXG AXGT AXK AXKT DS80625 KEYSET MKL-1 MKL-2 MKL-3 MKL-4 TS-AN

DESCRIPTION Pair of End Stops for 35mm DIN Rail Primary voltage terminal cover Replacement relays (3-pack) Replacement relays (3-pack) Flush surface mount backplate kit Split ring remote current sensor assembly (Wire Output) Split ring remote current sensor assembly (Terminal Output) Remote mini current sensor assembly (Wire Output) Remote mini current sensor assembly (Terminal Output) No. 8 x 5/8 Self-Tapping Drill Screws One set of 2 keys Locking key latch assembly Locking key-hook latch assembly Metal locking key latch assembly Coin locking key latch assembly Pluggable terminal strips

FOR USE WITH MODEL(S) ADIN35
Functional Devices 300 VA and 500 VA power supplies RIBR24D, RIBR24SD
RIBRL1C, RIBRL1S, RIBRXLCA, RIBRXLCF, RIBRXLSA WWS2-EN3
RIBXJA, RIBXJF, RIBXLCJA, RIBXLCJF, RIBXLSJA, RIBXLSJF RIBXJA, RIBXJF, RIBXLCJA, RIBXLCJF, RIBXLSJA, RIBXLSJF RIBXLCRA, RIBXLCRF, RIBXLSRA, RIBXLSRF, RIBXRA, RIBXRF RIBXLCRA, RIBXLCRF, RIBXLSRA, RIBXLSRF, RIBXRA, RIBXRF
Functional Devices polymetal sub-panels Functional Devices key latch metal enclosures Functional Devices metal enclosures except MH3300K Functional Devices MH3300K metal enclosures Functional Devices metal enclosures except MH3300K Functional Devices metal enclosures except MH3300K
RIBAN12C, RIBAN24C

= UL Component Recognized ; USA & Canada

# = 32 mm x 15 mm asymmetrical DIN rail EN50035; 35 mm x 7.5 mm symmetrical DIN rail EN50022; 22.4 mm x 6.9 mm symmetrical NEMA A Series rail

For full product information, see data sheets on website. Shipping weights are approximate and may change due to packaging options.

(800) 888-5538 | www.functionaldevices.com

81

ACCESSORIES

NOTES

ACCESSORIES

82

Functional Devices, Inc. | American Made. American Owned.

ENERGY SAVING DEVICES

HAF3

CLC212-D15 CLC106

Magnetic switch set included with CLC106 models

ACLCMAGSM

ACLCMAGDJ

ENERGY SAVING DEVICES
Half-Light® Ballast Controllers
For Multiple Ballast Fixtures, Step Dimming Control & Alternate Fixture Control Applications
Providing independent control for multiple ballast light fixtures from a single existing wall switch or from a lighting controller output, Half-Light® Ballast Controllers can significantly reduce a building's light output. This enables professional lighting users to enjoy the cost-effective benefits of lighting control with just a simple toggle of their wall-based light switch. Easy to use and install, Half-Light® Ballast Controllers from Functional Devices are fully compatible with the market's range of popular fluorescent and HID lamps. Half-Light® Ballast Controllers are a simple and affordable alternative to the industry's costlier and more complicated dimming systems and components.

HALF-LIGHT® BALLAST CONTROLLERS

MODEL # HAF2

POWER INPUT

BALLAST

RELAY

SIZE

TWO OR

CONTACTS ENCLOSURE THREE STAGE

· 120 / 208-277 Vac 1 SPST

·

2

HAF3

· 120 / 208-277 Vac 2 SPST

·

3

Product Selection Guide. For full product information, see our website.

4 BULB FIXTURES
·

6 BULB FIXTURES

MULTIPLE BALLAST FIXTURES
·

STEP DIMMING CONTROL
·

ALTERNATE FIXTURE CONTROL
·

SHIPPING WEIGHT
0.250 lb.

·

·

·

·

0.277 lb.

SEE DATA SHEETS FOR MORE INFORMATION ON APPLICATIONS.

= UL Listed : UL916 Energy Management ; USA & Canada
For full product information, see data sheets on website. Shipping weights are approximate and may change due to packaging options.

84

Functional Devices, Inc. | American Made. American Owned.

ENERGY SAVING

ENERGY SAVING DEVICES

Closet Light Controllers
For Use in Closets, Pantries, Walk-ins, and Cabinets
Our Light Controllers are designed to switch lighting loads on and off by the closing or opening of a variety of switches, including door jamb, magnetic, and ball switches. Models are available for
retrofit and new contruction jobs, with or without an energy-saving time out setting.

Retrofits

Retaining Clip

120 Vac Supply Neutral

To Light Fixture

Switched Leg

Normally Open Magnetic Door Switch

Octagonal Junction Box with Knockout

· 5 Amp relay

· 120 Vac power

· Fits easily inside junction box

· Includes retaining clip

· No transformer needed (dry contact input)

· Model CLC106, CLC106-NC

· Includes magnetic door jamb switch

New Construction

Class 2 Wiring CLC212
Closet Light
N/C Dry Contact Door Switch (not included)

Light Fixture Junction Box
Class 2 Wiring

120 Vac Power
Line Neutral

Closet Door

Light Fixture Blk Junction Box
Wht Red

15 Minute Time Out 60 Minute Time Out

· 10 Amp N/O relay · 120-277 Vac power · No transformer needed (dry contact input) · Light 18 AWG wire used to control relay, instead of
armored cable · Models CLC212, CLC212-D15, CLC212-D60 · Switch sold separately (ACLCMAGSM, ACLCMAGDJ)

CLOSET LIGHT CONTROLLERS

MODEL # CLC106 CLC106-NC CLC212 CLC212-D15 CLC212-D60

POWER INPUT

·

120 Vac

·

120 Vac

· 120-277 Vac

· 120-277 Vac

· 120-277 Vac

RELAY CONTACTS 1 SPST-N/O 1 SPST-N/C 1 SPST-N/O 1 SPST-N/O 1 SPST-N/O

Product Selection Guide. For full product information, see our website.

ACCESSORY SWITCH REQUIRED ^ N/O # N/C # N/C N/O N/O

TIME OUT N/A N/A N/A
15 min. 60 min.

OUTPUT WHEN SWITCH OPENS
On Off Off On On

HOUSING STYLE *
See data sheet See data sheet
A A A

SHIPPING WEIGHT 0.271 lb. 0.266 lb. 0.301 lb. 0.310 lb. 0.301 lb.

MAGNETIC SWITCHES

MODEL # ACLCMAGSM ACLCMAGDJ

VOLTAGE MAX. 30 Vac/dc 200 Vdc

CURRENT MAX. 0.2 Amp 0.5 Amp

Product Selection Guide. For full product information, see our website.

RELAY CONTACTS 1 SPDT (Form C) 1 SPDT (Form C)

MOUNT Surface Recessed

OPERATING GAP (MIN.) 1.125" 0.375"

SHIPPING WEIGHT 0.240 lb. 0.033 lb.

= UL Listed : UL916 Energy Management ; USA & Canada # = Integral switch included

^ = Normal state is when no outside forces (like a magnet) are acting on it. * = See Housing Guide on pages 86-87

For full product information, see data sheets on website. Shipping weights are approximate and may change due to packaging options.

(800) 888-5538 | www.functionaldevices.com

85

ENERGY SAVING

HOUSING GUIDE

HOUSING A
22..8800"" 11..7700""
0.50" NPT
11.5.500""

HOUSING B
33..2200""

HOUSING C
44..0000""

2..3300""

0.50" or 0.75" NPT 11..8811""

0.50" NPT

44..0000"" 44..5577""

11.81"

HOUSING D

7.00"

2.00""

INDEX & REFERENCES
4.28"

4.28"
0.75" NPT
RED ("-RD") and NEMA 4 ("-N4") HOUSINGS AVAILABLE.
See our website for details.

86

Functional Devices, Inc. | American Made. American Owned.

HOUSING GUIDE

SOLID CORE CURRENT SENSOR
11.4.466"0"

0.50" Diameter

11.8.6836" 3" 22..00550"0"

1.10.00088"" 22.0.05500" "

SPLIT CORE CURRENT SENSOR

2.000"

2.5200"

0.52" x 0.52" Opening
2.520"

11..11000" 1.7500""

SINGLE POWER SUPPLY

DUAL POWER SUPPLY

55.4.43388" 55.1.15500""

44.5.50000"

ON 44..550000""

RESET

OFF

44.2.25500""

OFF

55..1150"

88.662255"" 88.225500""

44..55000"

ON

ON 44..550000""

OFF

OFF

RESET

44..2250""

OFF

88.2500""

INDEX & REFERENCES

(800) 888-5538 | www.functionaldevices.com

87

NOTES

INDEX & REFERENCES

88

Functional Devices, Inc. | American Made. American Owned.

NOTES

INDEX & REFERENCES

(800) 888-5538 | www.functionaldevices.com

89

NOTES

INDEX & REFERENCES

90

Functional Devices, Inc. | American Made. American Owned.

ACLCMAGDJ ACLCMAGSM ADIN35 ADIN35ES APS53-TC ARL1C AR24D AT4-12 AT4-2 AT4-24 AT4-48 AT4-6 AWSTFM AXG AXGT AXK AXKT CLC106 CLC106-NC CLC212 CLC212-D15 CLC212-D60 CTRL-PS DS80625 HAF2 HAF3 KEYSET MH1000 MH1010 MH1020 MH1200 MH1210 MH1220 MH2204-N4 MH3100-M1 MH3204-N4 MH3300 MH3300K MH3303 MH3303K MH3304 MH3304K MH3500 MH3510 MH3520 MH3800 MH3803L MH3803S MH3804L MH3804S MH3810 MH3820 MH4400 MH4403L MH4404L MH4604S

INDEX

85 MH5500

77 PSH24DWB10

58 RIB01SBDC

41 RIBL24SBM

38

85 MH5503L

77 PSH2C2RB10

69 RIB023P

36 RIBL3C

34

81 MH5504L

77 PSH2C2RB10-L

69 RIB02BDC

41 RIBL4C

34

81 MH5800

77 PSH2RB10

69 RIB02P

36 RIBLB

42

81 MH5803L

77 PSH300A

57 RIB02P30

36 RIBLB-2

42

81 MH5804L

77 PSH300A-LVC

57 RIB02SBCDC

41 RIBLB-4

42

81 MHP3903100A100AB10 58 PSH300AB10-LVC

57 RIB02SBDC

41 RIBLB-6

42

81 MHP3903100AB10

58 PSH40A

57 RIB043P

36 RIBM013PN

37

81 MHP3904100A100AB10 58 PSH40AB10

57 RIB04P

36 RIBM013PNDC

41

81 MHP3904100AB10

58 PSH40AB10-EXT2

57 RIB12C-FA

40 RIBM01ZNDC

41

81 MHP4604100A100AB10 58 PSH40AW

57 RIB12P

36 RIBM023PN

37

81 MHP4604100AB10

58 PSH40AWB10

57 RIB12P30

36 RIBM02ZNDC

41

81 MKL-1

81 PSH500A

57 RIB12S-FA

40 RIBM043PN

37

81 MKL-2

81 PSH500A-LVC

57 RIB21CDC

41 RIBM043PN-HD

37

81 MKL-3

81 PSH500AB10-LVC

57 RIB2401B

36 RIBM12C

35

81 MKL-4

81 PSH600-UPS

69 RIB2401D

34 RIBM12S

35

81 MT212-12

81 PSH600-UPS-BC

69 RIB2401SB

36 RIBM2401B

37

85 MT212-18

81 PSH600-UPS-STAT

69 RIB2401SBC

36 RIBM2401D

35

85 MT212-2

81 PSH75A

57 RIB2402B

36 RIBM2401SB

37

85 MT212-24

81 PSH75A75A

57 RIB2402D

34 RIBM2401SBC

37

85 MT212-4

81 PSH75A75AB10

57 RIB2402SB

36 RIBM2402B

37

85 MT212-48

81 PSH75A75AW

57 RIB2402SBC

36 RIBM2402D

35

58 MT212-6

81 PSH75A75AWB10

57 RIB2421B

36 RIBM2402SB

37

81 MT212-8

81 PSH75AB10

57 RIB2421C

34 RIBM2402SBC

37

84 MT4-10

81 PSH75AW

57 RIB2421SB

36 RIBM243PN

37

84 MT4-12

81 PSH75AWB10

57 RIB243P

36 RIBM24C

35

81 MT4-18

81 PSH850-UPS-STAT

69 RIB24C-FA

40 RIBM24S

35

77 MT4-2

81 PSM19A24DAS

58 RIB24P

36 RIBM24ZL

37

77 MT4-24

81 PSM20A12DAS

58 RIB24P-FA

40 RIBM24ZN

37

77 MT4-4

81 PSM24A24DAS

58 RIB24P30

36 RIBME2401B

39

77 MT4-48

81 PSM2RB10

69 RIB24S-FA

40 RIBME2402B

39

77 MT4-6

81 PSMN01SB10

69 RIB24Z

36 RIBMH1C

35

77 MT4-8

81 PSMN01SB4

69 RIB347P

36 RIBMH1S

35

77 PE6000

77 PSMN200A

57 RIBAN12C

35 RIBMH1SC

35

77 PE6000-N4

77 PSMN24DA

58 RIBAN24C

35 RIBMH1SM-250

35

77 PE6010

77 PSMN24DAS

58 RIBD01BDC

41 RIBMH2C

35

77 PE6010-N4

77 PSMN24SB10

69 RIBD01BDC-DOB

41 RIBMN12C

35

77 PE6020

77 PSMN24SB4

69 RIBD02BDC

41 RIBMN12C-FA

40

77 PE6020-N4

77 PSMN2C2RB10

69 RIBD02BDC-DOB

41 RIBMN12S

35

77 PSB100AB10

57 PSMN300A

57 RIBD2421C

34 RIBMN12S-FA

40

77 PSB40AB10

57 PSMN40A

57 RIBH1C

34 RIBMN2401D

35

77 PSC100AB10

57 PSMN40A24DS

58 RIBH1CW

35 RIBMN24C

35

77 PSC40AB10

57 PSMN40AS

57 RIBH1S

34 RIBMN24C-4T

35

77 PSH100A

57 PSMN500A

57 RIBH1SC

34 RIBMN24C-FA

40

77 PSH100A100A

57 PSMS1

69 RIBH1SM-250

34 RIBMN24Q2C

42

77 PSH100A100AB10

57 PSP24DA

58 RIBH2C

34 RIBMN24Q3C

42

77 PSH100A100AW

57 PSPT2RB10

69 RIBHX24BA

52 RIBMN24Q4C

42

77 PSH100A100AWB10 57 PSPT2RB4

69 RIBHX24BF

52 RIBMN24Q4C-PX

42

77 PSH100A24DWB10

58 PSPW2RB10

69 RIBL12B

38 RIBMN24S

35

77 PSH100AB10

57 PSPW2RB4

69 RIBL12BM

38 RIBMN24S-4T

35

77 PSH100AB10-EXT2

57 RIB013P

36 RIBL12SB

38 RIBMN24S-FA

40

77 PSH100AW

57 RIB01BDC

41 RIBL12SBM

38 RIBMN24S-J

35

77 PSH100AWB10

57 RIB01P

36 RIBL1C-DC

34 RIBMN24ZL

37

77 PSH200A

57 RIB01P30

36 RIBL24B

38 RIBMNA1D0

42

77 PSH200A-LVC

57 RIB01P30-S

36 RIBL24BM

38 RIBMNH1C

35

77 PSH200AB10-LVC

57 RIB01SBCDC

41 RIBL24SB

38 RIBMNH1S

35

(800) 888-5538 | www.functionaldevices.com

91

INDEX & REFERENCES

INDEX

RIBMNH1SM-250

35 RIBT24Z

37 RIBW277B-EN3

73 RIBXLSEA

52 TR40VA003

64

RIBMNLB

42 RIBTD2401B

37 RIBX243PA

52 RIBXLSEV

52 TR40VA004

64

RIBMNLB-1

42 RIBTE01B

39 RIBX243PF

52 RIBXLSF

52 TR40VA013

64

RIBMNLB-2

42 RIBTE01P

39 RIBX243PV

52 RIBXLSJA

52 TR40VA015

64

RIBMNLB-2NO

42 RIBTE01P-S

39 RIBX24BA

52 RIBXLSJF

52 TR40VA022

64

RIBMNLB-4

42 RIBTE01SB

39 RIBX24BF

52 RIBXLSRA

52 TR40VA040

64

RIBMNLB-4NO

42 RIBTE02B

39 RIBX24BV

52 RIBXLSRF

52 TR50VA001

64

RIBMNLB-6

42 RIBTE02P

39 RIBX24SBA

52 RIBXLSV

52 TR50VA001US

62

RIBMNLB-6NO

42 RIBTE02P-S

39 RIBX24SBF

52 RIBXRA

51 TR50VA002

64

RIBMNU1C

35 RIBTE02SB

39 RIBX24SBV

52 RIBXRF

51 TR50VA003

64

RIBMNU1S

35 RIBTE24B

39 RIBXA

51 RIBXV

51 TR50VA004

64

RIBMNU1SM-250

35 RIBTE24P

39 RIBXF

51 SIB02S

69 TR50VA005

64

RIBMNW24B-BCAI

47 RIBTE24SB

39 RIBXG21A

51 SIB04S

69 TR50VA005US

62

RIBMNW24B-MBAI

47 RIBTELC

39 RIBXG21F

51 SIB05S

69 TR50VA006

64

RIBMNWD12-BC

47 RIBTELS

39 RIBXG21TA

51 SIBLS

69 TR50VA007

64

RIBMNWD12-BCDI

47 RIBTH1C

35 RIBXG21TF

51 SP3303

81 TR50VA008

64

RIBMNWLB-7-BC

42 RIBTH1S

35 RIBXG420-100

51 SP3304

81 TR50VA009

64

RIBMNWX2401B-BC 47 RIBTH1SC

35 RIBXG420-20

51 SP3803L

81 TR50VA014

64

RIBMNWX2401SB-LN 47 RIBTH2C

35 RIBXG420-50

51 SP3803S

81 TR50VA015

64

RIBMNWX2402B-BC 47 RIBTU1C

35 RIBXGA

51 SP3804L

81 TR50VA016

64

RIBMNWX2402SB-LN 47 RIBTU1S

35 RIBXGA-SCAL

51 SP3804S

81 TR50VA017

64

RIBMU1C

35 RIBTU1SC

35 RIBXGF

51 SP4403L

81 TR50VA018

64

RIBMU1S

35 RIBTU2C

35 RIBXGFL

51 SP4404L

81 TR50VA019

64

RIBMU1SC

35 RIBTW2401B-BC

47 RIBXGHA

51 SP5503L

81 TR50VA022US

62

RIBMU1SM-250

35 RIBTW2401B-LN

47 RIBXGHF

51 SP5504L

81 TR75VA001

64

RIBMU2C

35 RIBTW2401B-WIUI-N4 47 RIBXGHTA

51 SP5803L

81 TR75VA002

64

RIBMW24B-44-BC

47 RIBTW2401SB-LN

47 RIBXGHTF

51 SP5804L

81 TR75VA003

64

RIBMW24SB-LNAI

47 RIBTW2402B-BC

47 RIBXGTA

51 TR100VA001

64 TR75VA004

64

RIBMW24SB-LNT2

47 RIBTW2402B-LN

47 RIBXGTA-SCAL

51 TR100VA001US

62 TR75VA005

64

RIBMW24SB-LNT3

47 RIBTW2402SB-LN

47 RIBXGTF

51 TR100VA002

64 TR75VA007

64

RIBMX24BA

52 RIBTW24B-BCAI

47 RIBXGTFL

51 TR100VA002-20

64 TS-AN

81

RIBMX24BF

52 RIBTW24B-BCAO

47 RIBXGTV10

51 TR100VA002US

62 WDWS-EN3

73

RIBMX24SBA

52 RIBTW24B-MBAI

47 RIBXGTV5

51 TR100VA004

64 WKC-EN3

73

RIBMX24SBF

52 RIBTW24B-WI-N4

47 RIBXJA

51 TR100VA005

64 WVSCM-EN3

73

RIBMX24SBV

52 RIBTW24SB-LNAI

47 RIBXJF

51 TR100VA008

64 WVSWM-EN3

73

RIBR24D

35 RIBTW24SB-LNT2

47 RIBXK420-100

51 TR100VA009

64 WWS2-EN3

73

RIBR24SD

35 RIBTW24SB-LNT3

47 RIBXK420-20

51 TR100VA009US

62

RIBRL1C

35 RIBTWX2401B-BC

47 RIBXK420-50

51 TR100VA015

64

RIBRL1S

35 RIBTWX2401SB-LN

47 RIBXKA

51 TR150VA001

64

RIBRXLCA

52 RIBTWX2402B-BC

47 RIBXKF

51 TR150VA002

64

RIBRXLCF

52 RIBTWX2402SB-LN

47 RIBXKTA

51 TR150VA008

64

RIBRXLSA

52 RIBU1C

34 RIBXKTF

51 TR175VA001

64

RIBT2401B

37 RIBU1CW

35 RIBXKTV5-10

51 TR175VA002

64

RIBT2401D

35 RIBU1S

34 RIBXKTV5-100

51 TR175VA003

64

RIBT2401SB

37 RIBU1SC

34 RIBXKTV5-20

51 TR20VA001

64

RIBT2401SBC

37 RIBU1SM-250

34 RIBXKTV5-50

51 TR20VA002

64

RIBT2402B

37 RIBU2C

34 RIBXLCA

52 TR20VA003

64

RIBT2402SB

37 RIBU2S2

34 RIBXLCEA

52 TR20VA004

64

RIBT2402SBC

37 RIBU2SC

34 RIBXLCEV

52 TR20VA007

64

RIBT242B

37 RIBW01B-EN3

73 RIBXLCF

52 TR240VA001

64

RIBT243B

37 RIBW01C-EN3

73 RIBXLCJA

52 TR300VA002

64

RIBT243P

37 RIBW02C-EN3

73 RIBXLCJF

52 TR375VA001

64

RIBT24B

37 RIBW208B-EN3

73 RIBXLCRA

52 TR40VA001

64

RIBT24B-FA

40 RIBW21BAO-EN3

73 RIBXLCRF

52 TR40VA001US

62

RIBT24P

37 RIBW240B-EN3

73 RIBXLCV

52 TR40VA002

64

RIBT24SB

37 RIBW24B-EN3

73 RIBXLSA

52 TR40VA002US

62

INDEX & REFERENCES

92

Functional Devices, Inc. | American Made. American Owned.

Functional Devices, Inc. · 101 Commerce Drive · Sharpsville, IN 46068 Sales: 800.888.5538 · Office: 765.883.5538 · Fax: 765.883.7505 sales@functionaldevices.com · www.functionaldevices.com
All rights reserved.
The following trademarks used herein are owned by Functional Devices, Inc. : RIB®, Relay in a Box®, RIB® logo, Adaptrack®, Half-Light® & Functional Devices, Inc.® Copyright © 2019 Functional Devices, Inc.


Adobe InDesign CC 14.0 (Macintosh) Adobe PDF Library 15.0