lkeene

Click Here

Contractor Information | Thermo Pride | Built Tough For Lifetime Comfort

Support - Thermo Pride | Built Tough For Lifetime Comfort

PDF preview unavailable. Download the PDF instead.

Thermo-Products-Parts-Book-106-082322
Parts and Specification Catalog
There are no prices in this book

Table of Contents

Thermo Pride products have been the name for high-quality, handcrafted, hometown values, and high-efficiency for 76 years. We offer a full line of oil and gas-fired warm air furnaces, coils and accessories.

Product specifications may change. Please refer to www.thermopride.com for the most current product specifications.

TABLE OF CONTENTS
Oil Furnaces and Accessories
Oil Furnaces - OH6, OL6, OD6, OH8, OL8, OT11, OT16, OL20 Oil Furnace Accessories Gas Furnaces and Accessories
Gas Furnaces - CLQS1 Gas Furnace Accessories Mobile Home/Cottage Furnaces and Accessories
Mobile Home/Cottage Furnaces - OME, GMD2, CMA4, CMC2 Series Mobile Home Accessories Air Conditioning Evaporator Coils
AC Evaporator Coils and Cabinets Air Handlers
Air Handlers with Optional Hydronic Heating Coil Plenums and Transitions
Plenums and Transitions Spirit Oil Furnaces & Accessories
Spirit Oil Furnaces Spirit Oil Furnace Accessories Spec Sheets OH6 Oil Highboy Specs OL6 Oil Lowboy Specs OD6 Oil Counterflow/Horizontal Specs OH8 Oil Highboy Specs OL8 Oil Lowboy Specs OL20 Oil Lowboy Specs OT11, OT16 Oil Specs CLQS1 Gas Multi-Position Specs OME Oil Mobile Home Specs GMD2 Gas Mobile Home Specs CMA4 Gas Mobile Home Specs CMC2 Gas Mobile Home Specs Air Handlers Specs Spirit Oil Spec Table - All Models Terms and Conditions Terms and Conditions

PAGE NO.
2 3
4 4
5 5
6
7
8
9 9
11 12 13 14 15 16 17 18 19 20 21 22 23 24
25

1

MODEL NO.

Oil Furnaces Furnace and Burner Must Be Ordered Separately

Prices effective: May 2, 2022

DESCRIPTION

AFUE% BECKETT/
CARLIN

AFUE% RIELLO

BTU/H OUTPUT

SHIPPING WEIGHT

380692 380835 380693 OH6FA072D48 OH6FA072DV4 OL6FA072D48 OL6RA072D48 OL6FA072DV5 OL6RA072DV5 OD6FA072D48 OD6RA072D48 OD6FA072DV5 OD6RA072DV5

TP2501 - Beckett AFG Oil Burner for 6 Series Carlin EZ-1 Oil Burner for 6 Series Riello BF3 Oil Burner for 6 Series Low-Profile Highboy, Front Flue Low-Profile Highboy, Front Flue Lowboy, Front Flue Lowboy, Rear Flue Lowboy, Front Flue Lowboy, Rear Flue Counterflow/Horizontal, Front Flue Counterflow/Horizontal, Rear Flue Counterflow/Horizontal, Front Flue Counterflow/Horizontal, Rear Flue

86

86.1 60,000/72,000/90,000

280

86

86.1 60,000/72,000/90,000

280

86.5/86 87

60,000/72,000/90,000

315

86.5/86 87

60,000/72,000/90,000

315

86.5/86 87

60,000/72,000/90,000

315

86.5/86 87

60,000/72,000/90,000

315

85.7/85 85.7 60,000/72,000/90,000

250

85.7/85 85.7 60,000/72,000/90,000

250

85.7/85 85.7 60,000/72,000/90,000

250

85.7/85 85.7 60,000/72,000/90,000

250

380754 380836 380756 OH8FA119D60 OH8FA119DV5 OL8FA119T60 OL8RA119T60

TP2502 - Beckett AFG Oil Burner for 8 Series Carlin EZ-1 Oil Burner for 8 Series Riello BF3 Oil Burner for 8 Series Highboy, Front Flue Highboy, Front Flue Lowboy, Front Flue Lowboy, Rear Flue

85.8/85 86 101,000/120,000/132,000

390

85.8/85 86 101,000/120,000/132,000

390

85

85 101,000/119,000/132,000

315

85

85 101,000/119,000/132,000

315

380737

TP1011 - Beckett AFG Oil Burner for 11 Series

ROB-11 OT11-105FBP OT11-105RBP

Riello ROB-11 Oil Burner for 11 Series Horizontal, Front Flue, Exposed Burner Horizontal, Rear Flue, Exposed Burner

83

83

101,000

445

83

83

101,000

445

380738

TP1021 - Beckett AFG Oil Burner for 16 Series

ROB-16 OT16-125FBP OT16-125RBP

Riello ROB-16 Oil Burner for 16 Series Horizontal, Front Flue, Exposed Burner Horizontal, Rear Flue, Exposed Burner

83

83

125,000

500

83

83

125,000

500

380739

TP1031 - Beckett AFG Oil Burner for 20 Series

ROB-20 OL20FA151T60 OL20RA151T60

Riello ROB-20 Oil Burner for 20 Series Lowboy, Front Flue Lowboy, Rear Flue

85

85

153,000

600

85

85

153,000

600

2

Oil Accessories

Prices effective: May 2, 2022

DESCRIPTION

PART NO.

FURNACE or ACCESSORY MODEL

SHIPPING WT. (lbs.)

4" Clean Out Assembly (Cover, Gasket, T-Bar, Nut) - Pair AOPS7586

OC2-5, OH2-16, OL2-39, OT5-16

2

Clean Out Plug Assembly - Each

S00S4489 OH6, OD6F, OL6, OH8, OD6R, OME

1

D6 Base

D6-BASE

OD6 Counterflow Applications Only

36

D6 Cottage Base

D6COT-BASE OD6 Counterflow Applications Only

46

Optional Fan Timer

AOPS7433

Only used with models using a

2

combination fan limit control

Combustion Air Intake Hood Kit

AOPS7402

General Application

3

Combusion Air Kit

PVB-2

5, 11, 16, 20 Series

14

Field Direct Vent Termination Kit (includes vent hood & 15' flexible vent pipe)

AOPS8393

OH6, OL6 & OD6

41

Field Direct Vent Termination Kit (includes vent hood & 15' flexible vent pipe)

AOPS8414

OH8, OL8

42

Sidewall Vent Accessory Kit for Beckett Burner*

AOPS8394

OH6, OH8, OL6, OL8 & OD6

4

Sidewall Vent Accessory Kit for Beckett NX Burner*

AOPS8412

OH6

4

Sidewall Vent Accessory Kit for Riello Burner*

AOPS8395

OH6, OH8, OL6, OL8 & OD6

3

Sidewall Vent Accessory Kit for Carlin Burner*

AOPS8432

OH6, OH8, OL6, OL8 & OD6

3

Blocked Vent Switch (Canadian Applications)

350156

All Oil

2

Combustion Air Kit for combustion air only w/Beckett AF/AFG burner

AOPS8397

OH8, OH6, OD6, OL5, OL6, OL8

6

Combustion Air Kit for combustion air only w/

Beckett NX Burner

AOPS8413

OH6

6

Combustion Air Kit for combustion air only w/Riello Burner AOPS8416

OH6, OH8, OL6, OL8 & OD6

6

Combustion Air Kit for combustion air only w/Carlin Burner AOPS8433

OH6, OH8, OL6, OL8 & OD6

3

2 Line System Kit for Riello

380705

Used on BF3/BF5 burner

1

Filter Rack, 16 x 25 in., takes 1" filter

AOPS7547

OH5, OH6, OH11

6

Filter Rack, 20 x 20 in.

AOPS8385

General Use

4

Filter Rack, 20 x 25 in.

AOPS8386

General Use

4

Filter Rack, 20 x 25 x 6 in.

AOPS7375

OH8, OH16

4

#5F Replacement Chamber w/rock wool and gaskets

AOPS7323

5, 11 Series

11

#16F Replacement Chamber w/rock wool and gaskets

AOPS7324

16, 20 Series

14

Note: Blower conversion kits available. Please call customer service with model number and serial number for pricing and availability.

*Required when using Field Direct Vent Termination Kit

3

Gas Furnaces

Prices effective: May 2, 2022

MODEL NO.

AFUE%

MAXIMUM A/C CAPACITY (tons)

BTU/H INPUT

SHIPPING WT. (lbs.)

GAS SINGLE-STAGE CONDENSING MULTI-POSITION MODELS (Upflow, Downflow, Horizontal) HIGH EFFICIENCY CONSTANT TORQUE ECM BLOWER MOTOR

CLQS1-050T36N

95

3

50,000

155

CLQS1-075T42N

95

3.5

75,000

166

CLQS1-100T48N

95

4

100,000

183

CLQS1-125T60N

95

5

125,000

196

All above gas furnaces supplied as natural gas with a propane kit included. For Energy Star qualified units, go to www.energystar.gov.

GAS ACCESSORIES

DESCRIPTION Concentric Vent Kit - 2"
Concentric Vent Kit - 3" Sidewall Vent Cap
LP Conversion Kit Nat. Conversion Kit Neutralizer Kit Mini Condensate Pump 50CLQ Base 125CLQ Base

PART NO.
AOPS7488 AOPS7489
370191 AOPS7749 AOPS7745
320095 AOPS7614 50CLQ-Base 125CLQ-Base

FURNACE
CLQS1-050, 075 CLQS1-100, 125
CLQS1 CLQS1 CLQS1 CLQS1 CLQS1 CLQS1-050 CCLQS1-075, 100, 125

SHIPPING WT. (lbs.) 11 11 2
1 1 6
5
15 18

CHX3, CDX3, CHB1, CDB1, CMA, CMC, CLHS1, CLQS1
4

Mobile Home/Cottage Furnaces Accessories

Prices effective: May 2, 2022

MODEL NO.

AFUE%

BTU/H OUTPUT

SHIPPING WT. (lbs.)

OIL MOBILE HOME/COTTAGE FURNACES

OME-72D36 (with PSC blower motor and Beckett AFG Burner)

86

60,000/72,000

OME-72T36 (with ECM blower motor and Beckett AFG Burner)

86

60,000/72,000

GMD2-60N GMD2-80N CMA4-50D36N CMA4-75D36N

GAS MOBILE HOME/COTTAGE FURNACES

81.6

50,000

81

65,000

95

48,000

95

72,000

CMC2-50D36N with PSC blower motor and integrated coil cabinet

95

48,000

CMC2-75D36N with PSC blower motor and integrated coil cabinet

95

72,000

CMC2-50DV3N with ECM blower motor and integrated coil cabinet

95

48,000

CMC2-75DV3N with ECM blower motor and integrated coil cabinet

95

72,000

DESCRIPTION
70-Base Cottage Base 4" Stainless Steel Vent Pipe (34" long) 1' Roof Jack 2' Roof Jack 3' Roof Jack Slope Adapter for roof pitch 2-1/2"--12" Slope Adapter for roof pitch 3-1/2"--12" 2" Concentric Vent Kit with 4" Adapter for 4" Roof Jack 2" Concentric Vent Kit with 5" Adapter for 5" Roof Jack Dual Pipe Flashing Kit Combustion Air Intake Hood Roof Jack Combustion Air Kit Flexible Stainless Steel Offset Vent Kit High Altitude Orifice Kit - 2001-4500 ft High Altitude Orifice Kit - 4501-6500 ft High Altitude Orifice Kit - 6501-8500 ft GMD1-80N Upgrade Blower Kit for 3 Ton AC Neutralizing Kit Mini Condensate Pump Transition Boot with Screen

MOBILE HOME ACCESSORIES

PART NO.
70-BASE 01COT-BASE
VP-1 TRJ-1 TRJ-2 TRJ-3 TSA-25 TSA-30 AOPS7483 AOPS7544 AOPS7484 AOPS7402 AOPS7512 AOPS7518 AOPS7732 AOPS7733 AOPS7734 AOPS2677 320095 AOPS7614 AOPS8419

FURNACE or ACCESSORY MODEL
OME, GMD, CMA OME, GMD, CMA
OME, GMD OME, GMD OME, GMD OME, GMD OME, GMD, CMA, CMC OME, GMD, CMA, CMC CMA, CMC CMA, CMC CMA, CMC OME, GMD
OME OME, GMD CMA, CMC CMA, CMC CMA, CMC GMD1-80 CMA, CMC CMA, CMC OME, GMD

210 210
185 185 185 185
220
220
220
220
SHIPPING WT. (lbs) 25 35 6 30 30 36 8 8 20 12 10 3 16 3 1 1 1 42 6 3 6

5

AC Evaporator Coils and Cabinets

Prices effective: May 2, 2022

*All coils come with TXV suitable for AC & HP applications*

THERMO PRIDE COLOR-MATCHED CASED COILS FOR UPFLOW FURNACES

CASED COIL MODEL NO.
HE33936PA212 HE47936PA212 HE50960PA212

CABINET DIM. W X D X H (in.)
21.25 X 21.25 X 19 21.25 X 21.25 X 29 21.25 X 21.25 X 29

PLENUM OPENING W X D (in.)
19.8 X 19.8 19.8 X 19.8 19.8 X 19.8

SHIPPING WEIGHT (lbs.)
50 72 72

CABINET NO. CE112S CE312T CE215T CE216T
CE217T

DOWNFLOW CABINET APPLICATIONS

FURNACE APPLICATION OD6 Downflow OD6 Downflow CLQS1-050 CLQS1-075, 100, 125
CLQS1-125

CABINET DIMENSIONS W X D X H (in.) 20 X 30 X 18
23.25 X 30 X 29.5 17.75 X 27.8 X 18.5 21.25 X 27.8 X 28.5
24.75 X 27.8 X 28.5

Uncased Coil Part No. (See Uncased Coil Pricing
Below) HE33936UA170 HE47936UA205 HE50960UA205 HE33936UA170 HE33936UA200 HE50960UA205 HE47936UA205 HE33936UA200 HE50960UA205 HE47936UA205

SHIPPING WEIGHT (lbs.)
36 48 30 42
44

MOBILE HOME CABINET APPLICATONS

CABINET NO. CE111S

FURNACE APPLICATION
OME, GMD, CMA

CABINET DIMENSIONS
W X D X H (in.) 18.75 X 24.75 X 20

Uncased Coil Part No.
(See Uncased Coil Pricing Below)
HE33936UA170

SHIPPING
WEIGHT (lbs.) 35

YOU MUST ORDER THE CABINET AND COIL SEPARATELY FOR THE APPLICATIONS ABOVE. THE CABINETS ABOVE ARE FOR USE WITH UNCASED COILS ONLY. COILS NOT INCLUDED WITH CABINET. SEE BELOW FOR UNCASED COIL PRICE.

UNCASED COILS

UNCASED COIL MODEL NO.
HE33936UA170 HE33936UA200 HE47936UA205 HE50960UA205

TONS 2 to 3 2 to 3 2 to 3 3.5 to 5.0

DIMENSIONS W X D X H (in.)
17 X 19.5 X 17 20 X 19.5 X 17 20.5 X 19.5 X 27 20.5 X 19.5 X 27

SHIPPING WEIGHT (lbs.)
32 32 50 50

All Thermo Pride coils are made by ADP and use the same model numbers that match with many other condenser manufactures. Please visit www.ahridirectory.org to match a Thermo Pride coil with one of those many condensers.

6

Air Handlers with Optional Hydronic Heating Coils

Prices effective: May 2, 2022

The Advantage of our Air Handler System
The Thermo Pride air handlers are designed to be used as a stand-alone cooling, stand-alone heating or combination heating and cooling air handler. The air handlers can be installed in a upflow or horizontal applications. The cooling coil comes factory installed. In heating mode, our air handler provides up to 70° temperature rise (at 180°F entering water temperature), which provides warmer air than many air handlers on the market. All units operate on 115V and coils use 410A refrigerant.
Our air handler requires little maintenance and provides efficiency, longevity, and worry-free comfort. It also comes with our standard 10-year coil and 5-year parts warrany.

MODEL NO.

COOLING BTU/H CAPACITY

COMPONENTS
AH2436AE1 (cabinet with factory installed A/C coil) 2-3 Ton, 115V,
ECM Blower Motor
HC1-B (Hydronic Coil), Inlet Temperature Range (F) 140-180 UA1-C (Upflow Adapter Cabinet) 1

24,000-36,000 --

HEATING BTU/H OUTPUT 2

SHIPPING WT. (lbs.)

--

130

32,000-75,000

21

--

43

AH4260AE1 (cabinet with factory installed A/C coil) 3.5-5.0 Tons

36,000-60,000

--

180

HC2-A (Hydronic Coil), Inlet Temperature Range (F) 140-180

--

55,000-120,000

34

UA2-C (Upflow Adapter Cabinet) 1

--

48

1 Return base including filter rack for upflow applications 2 Based on 180°F boiler water temperature and 7 GPM circulator

7

Plenums and Transitions

FURNACE MODEL

PART NO.

DIMENSIONS WxDxH (in.)

OH6
AH4260AE1, OH8, OL6, OT11, VH8, VL8, VLR, VLF, CLQS1-075T42N, 100T48N, 125T60N

SUPPLY PLENUMS

PK181X191

18 x 19 x 36

PK202X202

20 x 20 x 36

CLQS1-050T36N OD6 OT16 VC VHF

PK164X202

14 x 20 x 36

PK181X201

18 x 20 x 36

PK201X221

20 x 22 x 36

PK163X163

16 x 16 x 36

PK192X192

19 x 19 x 36

RETURN PLENUMS

OL6 VL8 OT11 OT16 OD6 VC VLR, VLF

PK181X201 PK161X201 PK202X202 PK201X221 PK181X191 PK163X163 PK126X202

18 x 20 x 36 20 x 16 x 36 20 x 20 x 36 20 x 22 x 36 18 x 19 x 36 16 x 16 x 36 12-1/2 x 20 x 36 TRANSITIONS

OH6, VHF

PT1819X2020

N/A

Transition from 18 x 19 plenum flanges to 20 x 20 6" high, includes S-Locks

Prices effective: May 2, 2022

RETURN BOOT AND DROP KIT

OH6, VHF, CLQS1-050T, 075T, 100T

RD2510X2516

N/A

Fits factory supplied optional filter rack (25 x 16), includes 25 x 10 x 60 drop, 90 degree boot and flexible starting collar

OH8, VH8, CLQS1-125T60N

RD2512X2520

N/A

Fits factory supplied optional filter rack (25 x 20), includes 25 x 12 x 60 drop, 90 degree boot and flexible starting collar

Note: Plenums ship knocked down

8

Spirit Oil Furnaces

Prices effective: May 2, 2022

MODEL NO.

AFUE%

BTU/H OUTPUT

SHIPPING WT. (lbs.)

OIL LOW PROFILE HIGHBOY FURNACES

PSC DIRECT DRIVE BLOWER MOTOR

VHF-ABP (with Beckett AFG)

85

VHF-ACP (with Carlin EZ-1HP)

86

CONSTANT TORQUE ECM BLOWER MOTOR

60,000/72,000/90,000

240

60,000/72,000/90,000

240

VHF-ABT (with Beckett AFG)*
VHF-ACT (with Carlin EZ-1HP)*
* Energy Star Qualified

85

60,000/72,000/90,000

275

86

60,000/72,000/90,000

275

OIL HIGHBOY FURNACES

PSC DIRECT DRIVE BLOWER MOTOR WITH BECKETT AFG BURNER

VH8FA119P60B

85

101,000/119,000/132,000

335

ECM BLOWER MOTOR WITH BECKETT AFG BURNER

VH8FA119T60B * * Energy Star Qualified

85

101,000/119,000/132,000

335

OIL LOWBOY FURNACES (Higher Capacity)

PSC DIRECT DRIVE BLOWER MOTOR

VLF-DBP (Front Flue with Beckett AFG)

85

70,000/88,000/98,000/114,000

305

VLR-DBP (Rear Flue with Beckett AFG)

85

70,000/88,000/98,000/114,000

305

VLF-DCP (Front Flue with Carlin EZ-1HP)

86

70,000/88,000/98,000/114,000

305

VLR-DCP (Rear Flue with Carlin EZ-1HP)

86

70,000/88,000/98,000/114,000

305

HIGH CAPACITY

VL8FA119P60B (front flue) VL8RA119P60B (rear flue)

85

101,000/119,000/132,000

345

85

101,000/119,000/132,000

345

OIL COUNTERFLOW / HORIZONTAL FURNACES
PSC DIRECT DRIVE BLOWER MOTOR WITH BECKETT AFG BURNER

VC-CBP

85

69,000/88,000/97,000

300

ACCESSORIES

DESCRIPTION

PART NO.

FURNACE

SHIPPING WT. (lbs.)

Combustible Floor Base

VC-Base

VC-CBP

23

4 Ton Upgrade Blower Kit

S00S4140

VC-CBP

44

4 Ton Upgrade Blower Kit

S00S4141

VLF-CBP, VLR-CBP

44

Field Direct Vent Termination Kit (includes vent hood & 15' flexible vent pipe) for Beckett and Carlin

AOPS8393

VHF-AB*, VHF-AC*

41

Field Direct Vent Termination Kit (includes vent hood

& 15' flexible vent pipe)

AOPS8414

VH8, VL8

42

Sidewall Vent Accessory Kit for Beckett Burner

(Required when using Field Direct Vent Termination

AOPS8394

VHF-AB*, VH8, VL8

4

Kits above.)

Sidewall Vent Accessory Kit for Carlin Burner

(Required when using Field Direct Vent

AOPS8432

VHF-AC*

3

Termination Kits above.)

Blocked Vent Switch for (Canadian Applications)

350156

All Models

2

Combustion Air Kit for Beckett AFG Burner for Combustion Air Kit for Carlin EZ-1 Burner
Combustion Air Kit for combustion air only

AOPS8397

VHF-AB*, VH8, VL8

6

AOPS8433

VHF-AC*

6

AOPS7482

VL*-CBP, VL*-DBP, VL*-DCP, VC-CBP

6

For Energy Star qualified units, go to www.energystar.gov. 9

Spec Sheets
Full specifications and manuals are available online at www.thermopride.com. Scan for all Current and Discontinued Specifications
10

OIL FIRED UPFLOW FURNACE SPECIFICATIONS

MODEL NO.

OH6FA072D48 / DV4 B OH6FA072D48 / DV4 R OH6FA072D48 / DV4 C

HEATING CAPACITY HEAT INPUT RATE (BTUH) OUTPUT BTUH1 SEASONAL EFFICIENCY2 LARGEST REC A/C3 NOMINAL TEMP RISE HEAT EXCHANGER AREA CASING HEIGHT (IN.): CASING WIDTH (IN.): CASING DEPTH (IN.): NOMINAL FLUE OUTLET DIA. APPROX SHIPPING WEIGHT LBS APPROVAL STANDARDS
QTY AND SIZE OF PERMANENT FILTERS ELECTRICAL REQUIREMENTS VAC/HZ/PH MAX FUSE SIZE (AMPS) PSC/ECM TOTAL CURRENT (AMPS) PSC/ECM
HEIGHT FROM FLOOR TO CENTER OF FLUE

High Fire 106,250 89,000
66

Med Fire 85,000 72,000 86.0% 4 Tons
66

Low Fire High Fire 70,000 106,250 60,000 90,000

66

66

Med Fire 85,000 73,000 86.1% 4 Tons
66

Low Fire 70,000 60,000
66

High Fire 106,250 90,000
66

Med Fire 85,000 71,000 86.0% 4 Tons
66

Low Fire 70,000 60,000
66

45" 20" 30" 5" 250 UL727 CAN/CSA B140.4 (1) 24 3/4" X 15 3/4" 120/60/1 15 / 15 8.7 / 12.1
40 3/4"

45" 20" 30" 5" 250 UL727 CAN/CSA B140.4 (1) 24 3/4" X 15 3/4" 120/60/1 15 / 15 8.7 / 12.1
40 3/4"

45" 20" 30" 5" 250 UL727 CAN/CSA B140.4 (1) 24 3/4" X 15 3/4" 120/60/1 15 / 15 8.7 / 12.1
40 3/4"

SUPPLY AIR OUTLET SIZE (W-IN. X D-IN.)

18" X 19" (20" X 20")5

18" X 19" (20" X 20")5

18" X 19" (20" X 20")5

RETURN AIR DUCTWORK CONNECTION FLANGE SIZE ON FILTER RACK (D-IN. X H-IN.) RETURN AIR INLET OPENING SIZE IN SIDE CASING (TO BE CUTOUT BY DEALER) (D-IN. X H-IN.)
2-LINE SYSTEM KIT FOR RIELLO COMBUSTION AIR KIT FIELD VENT TERMINATION KIT SIDEWALL VENT ACCESSORIES KIT BLOCKED VENT KIT4 OIL BURNER SUPPLY PLENUM RETRUN BOOT & DROP KIT CASED COIL 2-3 TON CASED COIL 2-3 TON HIGH EFF. CASED COIL 3.5-4 TON

24 1/2" X 15"
23" X 14"
N/A AOPS8397 AOPS8393 AOPS8394 AOPS2686 BECKETT AFG (380692) PK181X191 RD2510X2516 HE33936PA212 HE47936PA212 HE50960PA212

24 1/2" X 15"
23" X 14"
ACCESSORY ITEMS 380705
AOPS8416 AOPS8393 AOPS8395 AOPS2686 RIELLO BF3 (380693) PK181X191 RD2510X2516 HE33936PA212 HE47936PA212 HE50960PA212

24 1/2" X 15"
23" X 14"
N/A AOPS8433 AOPS8393 AOPS8432 AOPS2686 CARLIN EZ-1HP (380835) PK181X191 RD2510X2516 HE33936PA212 HE47936PA212 HE50960PA212

1 OUTPUT BTUH BASED ON ANNUAL FUEL UTILIZATION EFFICIENCY RATED BY MANUFACTURER. 2 SEASONAL EFFICIENCY (ALSO CALLED AFUE - ANNUAL FUEL UTILIZATION EFFICIENCY) RATINGS ARE BASED ON TESTS FOLLOWING U.S. DEPARTMENT OF ENERGY TEST
PROCEDURES. 3 TO PERMIT LARGEST RECOMMENDED AIR CONDITIONING (AT .5 STATIC PRESSURE), SELECTION OF THE HIGHEST MOTOR SPEED IS REQUIRED. 4 NOT TO BE USED IN SIDEWALL VENT APPLICATIONS, USE ONLY WHEN CHIMNEY VENTED. 5 PLENUM ADAPTERS INCLUDED WITH UNIT MUST BE INSTALLED FOR 20"x20" PLENUM.

PS020001

11

ECN 5713-MA 220406

OIL FIRED UPFLOW FURNACE SPECIFICATIONS

MODEL NO.
HEATING CAPACITY HEAT INPUT RATE (BTUH) OUTPUT BTUH1 SEASONAL EFFICIENCY2 LARGEST REC A/C3 NOMINAL TEMP RISE HEAT EXCHANGER AREA CASING HEIGHT (IN.): CASING WIDTH (IN.): CASING DEPTH (IN.): NOMINAL FLUE OUTLET DIA. APPROX SHIPPING WEIGHT LBS APPROVAL STANDARDS
QTY AND SIZE OF PERMANENT FILTERS

OL6*A072D48/DV5 B OL6*A072D48/DV5 R OL6*A072D48/DV5 C

High Fire Med Fire Low Fire

106,250 85,000 70,000

89,000 72,000 60,000

86.5%

4 Tons / 5 Tons

66

66

66

High Fire Med Fire Low Fire

106,250 85,000 70,000

90,000 73,000 60,000

87.0%

4 Tons / 5 Tons

66

66

66

High Fire Med Fire Low Fire

106,250 85,000 70,000

89,000 72,000 60,000

86.0%

4 Tons / 5 Tons

66

66

66

34-3/4" 20" 50" 5" 250
UL727 CAN/CSA B140.4
(2) 19-3/4" X 13-3/4"

34-3/4" 20" 50" 5" 250
UL727 CAN/CSA B140.4
(2) 19-3/4" X 13-3/4"

34-3/4" 20" 50" 5" 250
UL727 CAN/CSA B140.4
(2) 19-3/4" X 13-3/4"

ELECTRICAL REQUIREMENTS VAC/HZ/PH MAX FUSE SIZE (AMPS) PSC/ECM TOTAL CURRENT (AMPS) PSC/ECM

120/60/1 15 / 15 8.7 / 12.3

120/60/1 15 / 15 8.7 / 12.3

120/60/1 15 / 15 8.7 / 12.3

HEIGHT FROM FLOOR TO CENTER OF FLUE

28-3/8"

28-3/8"

28-3/8"

SUPPLY AIR OUTLET SIZE (W-IN. X D-IN.) RETURN AIR INLET OPENING SIZE (W-IN. X D-IN.)
2-LINE SYSTEM KIT FOR RIELLO COMBUSTION AIR KIT FIELD VENT TERMINATION KIT SIDEWALL VENT ACCESSORIES KIT BLOCKED VENT KIT4 OIL BURNER SUPPLY PLENUM RETRUN PLENUM CASED COIL 2-3 TON CASED COIL 2-3 TON HIGH EFF. CASED COIL 3.5-5 TON

18" X 20" (20" X 20")5
18" X 18" (20" X 18")5
N/A AOPS8397 AOPS8393 AOPS8394 AOPS2686 BECKETT AFG (380692) PK202X202 PK181X201 HE33936PA212 HE47936PA212 HE50960PA212

18" X 20" (20" X 20")5
18" X 18" (20" X 18")5
ACCESSORY ITEMS 380705
AOPS8416 AOPS8393 AOPS8395 AOPS2686 RIELLO BF3 (380693) PK202X202 PK181X201 HE33936PA212 HE47936PA212 HE50960PA212

18" X 20" (20" X 20")5
18" X 18" (20" X 18")5
N/A AOPS8433 AOPS8393 AOPS8432 AOPS2686 CARLIN EZ-1HP (380835) PK202X202 PK181X201 HE33936PA212 HE47936PA212 HE50960PA212

1 OUTPUT BTUH BASED ON ANNUAL FUEL UTILIZATION EFFICIENCY RATED BY MANUFACTURER. 2 SEASONAL EFFICIENCY (ALSO CALLED AFUE - ANNUAL FUEL UTILIZATION EFFICIENCY) RATINGS ARE BASED ON TESTS FOLLOWING U.S. DEPARTMENT OF ENERGY TEST
PROCEDURES. 3 TO PERMIT LARGEST RECOMMENDED AIR CONDITIONING (AT .5 STATIC PRESSURE), SELECTION OF THE HIGHEST MOTOR SPEED IS REQUIRED. 4 NOT TO BE USED IN SIDEWALL VENT APPLICATIONS, USE ONLY WHEN CHIMNEY VENTED. 5 PLENUM ADAPTERS, INCLUDED WITH UNIT, MUST BE INSTALLED FOR 20" PLENUM WIDTH.

PS020017

12

ECN 5713-MA 220406

OIL FIRED COUNTERFLOW/*HORIZONTAL FURNACE SPECIFICATIONS

MODEL NO.
HEATING CAPACITY HEAT INPUT RATE (BTUH) OUTPUT BTUH1 SEASONAL EFFICIENCY2 LARGEST REC A/C3 NOMINAL TEMP RISE HEAT EXCHANGER AREA CASING HEIGHT (IN.): CASING WIDTH (IN.): CASING DEPTH (IN.): NOMINAL FLUE OUTLET DIA. APPROX SHIPPING WEIGHT LBS APPROVAL STANDARDS
QTY AND SIZE OF PERMANENT FILTERS

OD6F/RA072D48(V5)B OD6F/RA072D48(V5)R OD6F/RA072D48(V5)C

High Fire Med Fire Low Fire High Fire Med Fire Low Fire High Fire Med Fire Low Fire

106,250 85,000 70,000 106,250 85,000 70,000 106,250 85,000 70,000

89,000 72,000 60,000

85.7%

4 Tons (5 Tons)

66

66

66

89,000 72,000 60,000

85.7%

4 Tons (5 Tons)

66

66

66

89,000 72,000 60,000

85.0%

4 Tons (5 Tons)

66

66

66

45" 20" 30" 5" 250 UL727 CAN/CSA B140.4
(2) 18-3/4" X 12-3/4"

45" 20" 30" 5" 250 UL727 CAN/CSA B140.4
(2) 18-3/4" X 12-3/4"

45" 20" 30" 5" 250 UL727 CAN/CSA B140.4
(2) 18-3/4" X 12-3/4"

ELECTRICAL REQUIREMENTS VAC/HZ/PH MAX FUSE SIZE (AMPS) PSC/ECM TOTAL CURRENT (AMPS) PSC/ECM HEIGHT FROM FLOOR TO CENTER OF FLUE (F/R)
SUPPLY AIR OUTLET SIZE (W-IN. X D-IN.) RETURN AIR INLET OPENING SIZE (W-IN. X D-IN.)

120/60/1 15 / 15 8.7 / 12.3 20-1/2" / 20-1/2"
18" X 20"
18" X 19"

2-LINE SYSTEM KIT FOR RIELLO COMBUSTION AIR KIT FIELD VENT TERMINATION KIT SIDEWALL VENT ACCESSORIES KIT COM BUSTIBLE FLOOR BASE COTTAGE BASE COIL CABINET BLOCKED VENT KIT4 OIL BURNER SUPPLY PLENUM RETURN PLENUM COUNTERFLOW CABINET / COIL 2-3TON CABINET / COIL 2-3TON HIGH EFF. CABINET / COIL 3.5-5 TON HORIZONTAL CASED COIL 2-3TON CASED COIL 2-3TON HIGH EFF. CASED COIL 3.5-5 TON

N/A AOPS8397 AOPS8393 AOPS8394 D6-BA SE D6COT-BASE CE112S, CE312T AOPS2686 BECKETT AFG (380692) PK181X201 PK181X191
CE112S / HE33936UA170 CE312T / HE47936UA205 CE312T / HE50960UA205
HE33936CH210 HE47936CH210 HE50960CH210

120/60/1 15 / 15 8.7 / 12.3
20-1/2" / 20-1/2"
18" X 20"
18" X 19"
ACCESSORY ITEMS 380705
A OPS8416 A OPS8393 A OPS8395 D6-BASE D6COT-BASE CE112S, CE312T A OPS2686 RIELLO BF3 (380693) PK181X201 PK181X191
CE112S / HE33936UA170 CE312T / HE47936UA205 CE312T / HE50960UA205
HE33936CH210 HE47936CH210 HE50960CH210

120/60/1 15 / 15 8.7 / 12.3 20-1/2" / 20-1/2"
18" X 20"
18" X 19"
N/A AOPS8433 AOPS8393 AOPS8432 D6-BA SE D6COT- BA SE CE112S, CE312T AOPS2686 CARLIN EZ-1HP (380835) PK181X201 PK181X191
CE112S / HE33936UA170 CE312T / HE47936UA205 CE312T / HE50960UA205
HE33936CH210 HE47936CH210 HE50960CH210

*Horizontal installation for left or right supply.
1 OUTPUT BTUH BASED ON ANNUAL FUEL UTILIZATION EFFICIENCY RATED BY MANUFACTURER. 2 SEASONAL EFFICIENCY (ALSO CALLED AFUE - ANNUAL FUEL UTILIZATION EFFICIENCY) RATINGS ARE BASED ON TESTS FOLLOWING U.S. DEPARTMENT OF ENERGY TEST
PROCEDURES. 3 TO PERMIT LARGEST RECOMMENDED AIR CONDITIONING (AT .5 STATIC PRESSURE), SELECTION OF THE HIGHEST MOTOR SPEED IS REQUIRED. 4 NOT TO BE USED IN SIDEWALL VENT APPLICATIONS, USE ONLY WHEN CHIMNEY VENTED.

PS020004

13

ECN 5753143-MA 21290490260

OIL FIRED UPFLOW FURNACE SPECIFICATIONS

MODEL NO.

OH8FA119D60/DV5B OH8FA119D60/DV5R OH8FA119D60/DV5C

HEATING CAPACITY
HEAT INPUT RATE (BTUH) OUTPUT BTUH1 SEASONAL EFFICIENCY2 LARGEST REC A/C3
NOMINAL TEMP RISE

High Fire 156,250 132,000
66

Med Fire 140,000 120,000 85.8% 5 Tons
66

Low Fire High Fire 119,000 156,250 101,000 132,000

66

66

Med Fire 140,000 120,000 86.0% 5 Tons
66

Low Fire 119,000 101,000
66

High Fire 156,250 132,000
66

Med Fire 140,000 120,000 85.0% 5 Tons
66

Low Fire 119,000 101,000
66

HEAT EXCHANGER AREA CASING HEIGHT (IN.): CASING WIDTH (IN.): CASING DEPTH (IN.): NOMINAL FLUE OUTLET DIA. APPROX SHIPPING WEIGHT LBS APPROVAL STANDARDS
QTY AND SIZE OF PERMANENT FILTERS

50 1/8" 24 1/2" 36 1/2"
7" 310 UL727 CAN/CSA B140.4 (1) 24 3/4" X 19 3/4"

50 1/8" 24 1/2" 36 1/2"
7" 310 UL727 CAN/CSA B140.4 (1) 24 3/4" X 19 3/4"

50 1/8" 24 1/2" 36 1/2"
7" 310 UL727 CAN/CSA B140.4 (1) 24 3/4" X 19 3/4"

ELECTRICAL REQUIREMENTS VAC/HZ/PH MAX FUSE SIZE (AMPS) PSC/ECM TOTAL CURRENT (AMPS) PSC/ECM

120/60/1 20/20

120/60/1 20/20

120/60/1 20/20

HEIGHT FROM FLOOR TO CENTER OF FLUE

42 1/2"

42 1/2"

42 1/2"

SUPPLY AIR OUTLET SIZE (W-IN. X D-IN.)

20" X 20"

20" X 20"

20" X 20"

RETURN AIR DUCTWORK CONNECTION FLANGE SIZE ON FILTER RACK (D-IN. X H-IN.)
RETURN AIR INLET OPENING SIZE IN SIDE CASING (TO BE CUTOUT BY DEALER) (D-IN. X H-IN.)

23 3/4" X 19" 23" X 14"

23 3/4" X 19" 23" X 14"

23 3/4" X 19" 23" X 14"

OPTIONAL REAR RETURN AIR OPENING (DIN X H-IN)

22" X 14"

22" X 14

22" X 14

2-LINE SYSTEM KIT FOR RIELLO FIELD VENT TERMINATION KIT5 SIDEWALL VENT ACCESSORIES KIT5
COMBUSTION AIR KIT BLOCKED VENT SWITCH4
OIL BURNER

N/A AOPS8414 AOPS8394 AOPS8397
350156 BECKETT AFG

ACCESSORY ITEMS 380705
AOPS8414 AOPS8395 AOPS8416
350156 RIELLO BF5

N/A N/A N/A N/A 350156 CARLIN EZ-1HP

1 OUTPUT BTUH BASED ON ANNUAL FUEL UTILIZATION EFFICIENCY RATED BY MANUFACTURER. 2 SEASONAL EFFICIENCY (ALSO CALLED AFUE - ANNUAL FUEL UTILIZATION EFFICIENCY) RATINGS ARE BASED ON TESTS FOLLOWING U.S. DEPARTMENT OF ENERGY TEST
PROCEDURES. 3 TO PERMIT LARGEST RECOMMENDED AIR CONDITIONING (AT .5 STATIC PRESSURE), SELECTION OF THE HIGHEST MOTOR SPEED IS REQUIRED. 4 NOT TO BE USED IN SIDEWALL VENT APPLICATIONS, USE ONLY WHEN CHIMNEY VENTED. 5 NOT TO BE USED WITH CARLIN BURNER.

PS020003

14

ECN 5583-MA 190617

OIL FIRED UPFLOW FURNACE SPECIFICATIONS

MODEL NO.
HEATING CAPACITY HEAT INPUT RATE (BTUH) OUTPUT BTUH1 SEASONAL EFFICIENCY2 LARGEST REC A/C3 NOMINAL TEMP RISE HEAT EXCHANGER AREA CASING HEIGHT (IN.): CASING WIDTH (IN.): CASING DEPTH (IN.): NOMINAL FLUE OUTLET DIA. APPROX SHIPPING WEIGHT LBS APPROVAL STANDARDS
QTY AND SIZE OF PERMANENT FILTERS
ELECTRICAL REQUIREMENTS VAC/HZ/PH MAX FUSE SIZE (AMPS) TOTAL CURRENT (AMPS)

OL8*A119T60 B

OL8*A119T60 R

OL8*A119T60 C

High Fire Med Fire Low Fire High Fire Med Fire Low Fire High Fire Med Fire Low Fire 156,250 140,000 119,000 156,250 140,000 119,000 156,250 140,000 119,000

132,000 67

119,000 85.0% 5 Tons
67

101,000 67

132,000 67

119,000 85.0% 5 Tons
67

101,000 67

132,000 67

119,000 85.0% 5 Tons
67

101,000 67

37-1/2" 24-1/2" 55-1/2"
7" 315 UL727
(2) 11-3/4" X 21-3/4"
120/60/1 20 16

37-1/2" 24-1/2" 55-1/2"
7" 315 UL727
(2) 11-3/4" X 21-3/4"
120/60/1 20 16

37-1/2" 24-1/2" 55-1/2"
7" 315 UL727
(2) 11-3/4" X 21-3/4"
120/60/1 20 16

HEIGHT FROM FLOOR TO CENTER OF FLUE

30-1/4"

30-1/4"

30-1/4"

SUPPLY AIR OUTLET SIZE (W-IN. X D-IN.) RETURN AIR INLET OPENING SIZE (W-IN. X D-IN.)
2-LINE SYSTEM KIT FOR RIELLO COMBUSTION AIR INTAKE HOOD KIT FIELD VENT TERMINATION KIT SIDEWALL VENT ACCESSORIES KIT OIL BURNER

20" X 20"
20" X 16"
N/A AOPS8397 AOPS8414 AOPS8394 BECKETT AFG 380754

20" X 20"
20" X 16"
ACCESSORY ITEMS 380705
AOPS8416 AOPS8414 AOPS8395 RIELLO BF5 380756

20" X 20"
20" X 16"
N/A AOPS8433 AOPS8414 AOPS8432 CARLIN EZ-1HP 380836

1 OUTPUT BTUH BASED ON ANNUAL FUEL UTILIZATION EFFICIENCY RATED BY MANUFACTURER. 2 SEASONAL EFFICIENCY (ALSO CALLED AFUE - ANNUAL FUEL UTILIZATION EFFICIENCY) RATINGS ARE BASED ON TESTS FOLLOWING U.S. DEPARTMENT OF ENERGY TEST
PROCEDURES. 3 TO PERMIT LARGEST RECOMMENDED AIR CONDITIONING (AT .5 STATIC PRESSURE), SELECTION OF THE HIGHEST MOTOR SPEED IS REQUIRED. .

PS020026

15

ECN 5447-MA 200129

OIL FIRED UPFLOW FURNACE SPECIFICATIONS

MODEL NO.
HEATING CAPACITY HEAT INPUT RATE (BTUH) OUTPUT BTUH1 SEASONAL EFFICIENCY2 LARGEST REC A/C3 NOMINAL TEMP RISE HEAT EXCHANGER AREA CASING HEIGHT (IN.): CASING WIDTH (IN.): CASING DEPTH (IN.): NOMINAL FLUE OUTLET DIA. APPROX SHIPPING WEIGHT LBS APPROVAL STANDARDS
QTY AND SIZE OF PERMANENT FILTERS
ELECTRICAL REQUIREMENTS VAC/HZ/PH MAX FUSE SIZE (AMPS) TOTAL CURRENT (AMPS)

OL20*A151T60 B
185,000 153,000 85.0% 5 Tons
70 7525 SQ IN
50-1/2" 27"
58-1/2" 7" 600
UL727 (2) 14" X 25"
120/60/1 20 18.9

OL20*A151T60 R
185,000 153,000 85.0% 5 Tons
70 7525 SQ IN
50-1/2" 27"
58-1/2" 7" 600
UL727 (2) 14" X 25"
120/60/1 20 18.9

HEIGHT FROM FLOOR TO CENTER OF FLUE

44-1/4"

44-1/4"

SUPPLY AIR OUTLET SIZE (W-IN. X D-IN.) RETURN AIR INLET OPENING SIZE (W-IN. X D-IN.)
COMBUSTION AIR INTAKE HOOD KIT OIL BURNER

22" X 22"

22" X 22"

22" X 18"

22" X 18"

ACCESSORY ITEMS

PVB-2

N/A

BECKETT AFG 380739

RIELLO F5 ROB-20

1 OUTPUT BTUH BASED ON ANNUAL FUEL UTILIZATION EFFICIENCY RATED BY MANUFACTURER. 2 SEASONAL EFFICIENCY (ALSO CALLED AFUE - ANNUAL FUEL UTILIZATION EFFICIENCY) RATINGS ARE BASED ON TESTS FOLLOWING U.S. DEPARTMENT OF ENERGY TEST
PROCEDURES. 3 TO PERMIT LARGEST RECOMMENDED AIR CONDITIONING (AT .5 STATIC PRESSURE), SELECTION OF THE HIGHEST MOTOR SPEED IS REQUIRED.

PS020027

16

ECN 5647-MA 200813

OIL FIRED FURNACE SPECIFICATIONS

MODEL SERIES BTU OUTPUT

BECKETT AFG RIELLO CARLIN

HEIGHT OF CASING WIDTH OF CASING DEPTH OF CASING WARM AIR OUTLET (WxD in inches) RETURN AIR INLET (WxD in inches) DIAMETER OF FLUE FLOOR TO CENTER OF FLUE (IN.)

STANDARD BLOWER MOTOR OPTIONAL ECM BLOWER MTR

CFM @ 0.2 &0.5 W.C.

BELT DRIVE

STANDARD D.D. HI SPEED

PSC

MH SPEED

MED. SPEED

ML SPEED

LOW SPEED

A/C CAPACITY

BELT3 D.D. PSC D.D. PSC UPGRADE

BECKETT

NOZZLE SIZE GPH SPRAY ANGLE/PATTERN PUMP PRESSURE

RIELLO

NOZZLE SIZE SPRAY ANGLE/PATTERN PUMP PRESSURE

SHIPPING WEIGHT (LBS.) SEASONAL AFUE BECKETT4 SEASONAL AFUE RIELLO

OT11-1051

HORIZONTAL

OT16-1251

101,000 101,000
N/A

123,000/134,550 123,000 N/A

24" 74" 24 1/2" 20"x20" 20"x20"

26" 74" 26" 22"x20" 22"x20"

6"

7"

1/2 HP 4-speed N/A

3/4 HP 4-speed N/A

0.2"

0.5"

0.2"

0.5"

1596 1329 1069 863

1408 1162 940 742

2237

2062

2020

1897

1877

1789

NOT RECOMMENDED

3 1/2 Ton 4 Ton
0.90 80° A 100 PSI
0.75 80° A 145
445 83% 83%

5 Ton
1.10 1.25 80° A
120 PSI
0.90 80° A 145
500 83% 83%

1)Alternate plenum flanges supplied with furnace, must be installed for 20" width.. All models on Chart are UL Listed. All specifications subject to change without notice.

PS020019 Rev 050222

17

SINGLE STAGE CONDENSING GAS MULTI-POSITION FURNACE SPECIFICATIONS

MODEL NO.
FUEL

CLQS1-050T36N
GAS NAT/LP 4

CLQS1-075T42N CLQS1-100T48N CLQS1-125T60N

GAS NAT/LP 4

GAS NAT/LP 4

GAS NAT/LP 4

INPUT BTUH

50,000

75,000

OUTPUT BTUH1 SEASONAL EFFICIENCY2 LARGEST REC A/C3 NOMINAL TEMP RISE APPROX EFFECTIVE HEATING SURFACE APPROX SHIPPING WEIGHT APPROVAL AGENCY DIA OF FLUE (PVC) DIA OF COMBUSTION AIRINTAKE (PVC) SUPPLY AIR OUTLET SIZE (W-IN x D-IN) RETURN AIR DUCTWORK CONNECTION ON FRIELTTUERRNRAAICRKIN(DL-EINT xOPHE-INNI)NG IN SIDE CASING (TO BE CUTOUT BY DEALER) (D-IN x H-IN)
QTY AND SIZE OF PERMANENT FILTERS ELECTRICAL RATING MAX FUSE SIZE
COMBUSTIBLE FLOOR BASE CE COIL CABINET FILTER RACK CONCENTRIC VENT KIT SIDEWALL VENT CAP NEUTRALIZER KIT MINI CONDENSATE PUMP KIT SUPPLY PLENUM RETURN AIR DROP FURNACE PARTS KIT

48,000 95.0%
3 T 60° 4225 SQ IN. 155 LBS ETL 2" 2" 16-1/2" x 20" (20"x20")5
24-1/2" x 15"
23-1/8" x 14-1/8"
ONE 1" x 25" x 16" 115V 60HZ 1PH
15 AMP
50CLQ-BASE CE215T
AOPS7547 AOPS7488
370191 320095 AOPS7614 PK164X202 RD2510X2516 AOPS7768

73,000 95.0% 3.5 T
60° 4490 SQ IN.
166 LBS ETL 2" 2"
20" x 20"
24-1/2" x 15"
23-1/8" x 14-1/8"
ONE 1" x 25" x 16" 115V 60HZ 1PH
15 AMP ACCESSORY ITEMS
125CLQ-BASE CE216T
AOPS7547 AOPS7488
370191 320095 AOPS7614 PK202X202 RD2510X2516 AOPS7768

100,000
96,000 95.0%
4 T 60° 5550 SQ IN. 183 LBS ETL 3" 3" 20" x 20" 24-1/2" x 15"
23-1/8" x 14-1/8"
ONE 1" x 25" x 16" 115V 60HZ 1PH
15 AMP
125CLQ-BASE CE216T
AOPS7547 AOPS7489
370191 320095 AOPS7614 PK202X202 RD2510X2516 AOPS7768

125,000
120,000 95.0%
5 T 60° 5815 SQ IN. 196 LBS ETL 3" 3" 20" x 20" 23-3/4" x 19"
23-1/8" x 14-1/8"
ONE 1" x 25" x 20" 115V 60HZ 1PH
15 AMP
125CLQ-BASE CE217T
AOPS7375 AOPS7489
370191 320095 AOPS7614 PK202X202 RD2512X2520 AOPS7768

1 OUTPUT BTUH BASED ON AHRI LISTING. 2 SEASONAL EFFICIENCY (ALSO CALLED AFUE - ANNUAL FUEL UTILIZATION EFFICIENCY) RATINGS ARE BASED ON TESTS FOLLOWING U.S. DEPARTMENT OF ENERGY TEST PROCEDURES. 3 TO PERMIT LARGEST RECOMMENDED AIR CONDITIONING (AT .5 STATIC PRESSURE), SELECTION OF THE HIGHEST MOTOR SPEED IS REQUIRED. 4 LP CONVERSION KIT SHIPPED WITH FURNACE. 5 PLENUM ADAPTERS INCLUDED WITH UNIT MUST BE INSTALLED FOR 20"x20" PLENUM. ALL SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
PS030010 ECN 5555-MA 181024

18

OIL-FIRED MOBILE HOME FURNACE SPECIFICATIONS

MODEL NO.
HEAT INPUT RATE (BTUH) OUTPUT (BTUH)1 SEASONAL EFFICIENCY2 FUEL NOMINAL TEMP. RISE CASING HEIGHT (IN.) CASING WIDTH (IN.) CASING DEPTH (IN.) FLUE DIAMETER (IN.) NOMINAL FLUE OUTLET DIAMETER (IN.) APPROX. SHIPPING WEIGHT (LBS.) APPROVAL AGENCY SIZE OF PERM. FILTER ELECTRICAL REQUIREMENTS MAX FUSE SIZE TOTAL RATED CURRENT AMPS. SUPPLY AIR OUTLET SIZE (W-IN X D-IN) RETURN AIR INLET OPENING SIZE NOMINAL HEAT ANTICIPATOR SETTING
MOBILE HOME BASE COTTAGE BASE COIL CABINET FOR 2-3 TON ROOF JACK 12" OR LESS ROOF JACK 13" TO 24" ROOF JACK 25" TO 36" VENT PIPE SLOPE ADAPTOR 2-1/2-12 SLOPE ADAPTOR 3-1/2-12 COMBUSTION AIR INTAKE HOOD TRANSITION BOOT w\ SCREEN BLOCKED VENT KIT3 ROOF JACK COMBUSTION AIR KIT OFFSET VENT KIT

OME-72D36 / OME-72T36

LOW FIRE

HIGH FIRE

70,000

85,000

60,000

72,000

86%

86%

#2 FUEL OIL

66º

57"

18"

24-3/4"

4"

4"

240 LBS.

ETL

18" X 24"

115 VAC / 60 HZ / 1 PHASE

15 AMPS

11

12" X 12"

14" X 22" (LOUVERED)

0.2mA

ACCESSORY ITEMS

70-BASE

01COT-BASE

CE111S

TRJ-1

TRJ-2

TRJ-3

VP-1

TSA-25

TSA-30

AOPS7402

AOPS8419

AOPS2686

AOPS7512

AOPS7518

1 OUTPUT BTUH BASED ON ANNUAL FUEL UTILIZATION EFFICIENCY RATED BY MANUFACTURER. 2 SEASONAL EFFICIENCY (ALSO CALLED AFUE-ANNUAL FUEL UTILIZATION EFFICIENCY) RATINGS ARE BASED ON TESTS FOLLOWING U.S. DEPARTMENT OF ENERGY TEST PROCEDURES. 3 NOT TO BE USED IN MOBILE HOME APPLICATIONS WITH A ROOF-JACK.

PS040004 ECN 5583-MA 190617
19

GAS-FIRED MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION)
FURNACE SPECIFICATIONS

MODEL NO.
HEAT INPUT RATE (BTUH) OUTPUT (BTUH)1 SEASONAL EFFICIENCY2
LARGEST REC A/C3
FUEL BURNER ORIFICE GAS SUPPLY PRESSURE (IN W.G.) MINIMUM REQUIRED MAXIMUM ALLOWED GAS MANIFOLD PRESSURE (IN W.G.) NOMINAL TEMP. RISE VENT PIPE SIZE (IN.) CASING HEIGHT (IN.) CASING WIDTH (IN.) CASING DEPTH (IN.) APPROX. SHIPPING WEIGHT (LBS.) APPROVAL AGENCY SIZE OF PERM. FILTER ELECTRICAL REQUIREMENTS MAX FUSE SIZE TOTAL RATED CURRENT AMPS. SUPPLY AIR OUTLET SIZE (W-IN X D-IN) RETURN AIR INLET OPENING SIZE
NOMINAL HEAT ANTICIPATOR SETTING
MOBILE HOME BASE COTTAGE BASE COIL CABINET 3 TON A/C UPGRADE KIT (GMD2-80 ONLY) ROOF JACK 12" OR LESS ROOF JACK 13" TO 24" ROOF JACK 25" TO 36" SLOPE ADAPTOR 2-1/2-12 SLOPE ADAPTOR 3-1/2-12 4" STAINLESS STEEL VENT PIPE (34" LG) COMBUSTION AIR INTAKE HOOD FLEXIBLE STAINLESS STEEL OFFSET VENT KIT TRANSITION BOOT W/ SCREEN

GMD2-60
60,000 50,000
81.6

2.5 TONS

NAT

LP

#38

#52

GMD2-80
80,000 65,000
81

2.5 TONS (AS SHIPPED) 3 TONS WITH UPGRADE KIT

NAT

LP

2.45mm

#53

5.5

11

5.5

14.0

14.0

14.0

3.5±0.3

10±0.3

3.5±0.3

60º

70º

4"

57"

18"

25 ¾"

165 LBS.

ETL

18" X 24"

115 VAC/ 60 HZ/ 1 PHASE

15 AMPS

7.15

12" X 12"

14" X 22"

0.8 mA

ACCESSORY ITEMS

70-BASE 01COT-BASE
CE111S
AOPS2677 TRJ-1 TRJ-2 TRJ-3 TSA-25 TSA-30 VP-1
AOPS7402

11 14.0 10±0.3

AOPS7518 AOPS8419

1 OUTPUT BTUH BASED ON ANNUAL FUEL UTILIZATION EFFICIENCY RATED BY MANUFACTURER. 2 SEASONAL EFFICIENCY (ALSO CALLED AFUE-ANNUAL FUEL UTILIZATION EFFICIENCY) RATINGS ARE BASED ON TESTS FOLLOWING U.S. DEPARTMENT OF ENERGY TEST PROCEDURES. 3 TO PERMIT LARGEST RECOMMENDED AIR CONDITIONING (AT .5 STATIC PRESSURE), SELECTION OF THE HIGHEST MOTOR SPEED IS REQUIRED.
PS040008 ECN 5580-MA
20

GAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE
SPECIFICATIONS

MODEL NO.
HEAT INPUT RATE (BTUH) OUTPUT (BTUH)1 SEASONAL EFFICIENCY2 LARGEST REC A/C3 FUEL BURNER ORIFICE GAS SUPPLY PRESSURE (IN W.G.) MINIMUM REQUIRED MAXIMUM ALLOWED GAS MANIFOLD PRESSURE (IN W.G.) NOMINAL TEMP. RISE VENT PIPE SIZE (IN.) CASING HEIGHT (IN.) CASING WIDTH (IN.) CASING DEPTH (IN.) APPROX. SHIPPING WEIGHT (LBS.) APPROVAL AGENCY SIZE OF PERM. FILTER ELECTRICAL REQUIREMENTS MAX FUSE SIZE TOTAL RATED CURRENT AMPS. SUPPLY AIR OUTLET SIZE (W-IN X D-IN) NOMINAL HEAT ANTICIPATOR SETTING
MOBILE HOME BASE COTTAGE BASE COIL CABINET FOR 2-3 TON CONCENTRIC VENT KIT (FOR 4" FLUE RJ) CONCENTRIC VENT KIT (FOR 5" FLUE RJ) DUAL PIPE FLASHING KIT BAYVENT SIDE WALL VENT KIT SLOPE ADAPTER 2-1/2 / 12 SLOPE ADAPTER 3-1/2 / 12 MINI CONDENSATE PUMP KIT NEUTRALIZING KIT

CMA4-50D36

50,000

48,000

95%

3 TONS

NAT

LP

#42

#54

CMA4-75D36

75,000

72,000

95%

3 TONS

NAT

LP

#42

#54

4.5

11

4.5

11

14

14

14

14

3.5±0.3

10±0.3

3.5±0.3

10±0.3

55º

65º

2" PVC

2" PVC

57"

57"

18"

18"

25 3/4"

25 3/4"

175 LBS.

185 LBS.

ETL

ETL

18" X 24"

18" X 24"

115 VAC/ 60 HZ/ 1 PHASE 115 VAC/ 60 HZ/ 1 PHASE

15 AMPS

15 AMPS

7.15

7.15

12" X 12"

12" X 12"

0.8mA

0.8mA

ACCESSORY ITEMS

70BASE

70BASE

01COT-BASE

01COT-BASE

CE111S

CE111S

AOPS7483

AOPS7483

AOPS7544

AOPS7544

AOPS7484

AOPS7484

370191

370191

TSA-25

TSA-25

TSA-30

TSA-30

AOPS7614 320095

AOPS7614 320095

1 OUTPUT BTUH BASED ON ANNUAL FUEL UTILIZATION EFFICIENCY RATED BY MANUFACTURER. 2 SEASONAL EFFICIENCY (ALSO CALLED AFUE-ANNUAL FUEL UTILIZATION EFFICIENCY) RATINGS ARE BASED ON TEST FOLLOWING U.S. DEPARTMENT OF ENERGY TEST PROCEDURES. 3 TO PERMIT LARGEST RECOMMENDED AIR CONDITIONING (AT .5 STATIC PRESSURE), SELECTION OF THE HIGHEST MOTOR SPEED IS REQUIRED.

PS040009
ECN 5580-MA 21

GAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE
SPECIFICATIONS

MODEL NO. HEAT INPUT RATE (BTUH) OUTPUT (BTUH)1 SEASONAL EFFICIENCY2 LARGEST REC A/C3 FUEL BURNER ORIFICE GAS SUPPLY PRESSURE (IN W.G.) MINIMUM REQUIRED MAXIMUM ALLOWED GAS MANIFOLD PRESSURE (IN W.G.) NOMINAL TEMP. RISE VENT PIPE SIZE (IN.) CASING HEIGHT (IN.) CASING WIDTH (IN.) CASING DEPTH (IN.) APPROX. SHIPPING WEIGHT (LBS.) APPROVAL AGENCY SIZE OF PERM. FILTER
ELECTRICAL REQUIREMENTS MAX FUSE SIZE TOTAL RATED CURRENT AMPS. SUPPLY AIR OUTLET SIZE (W-IN X D-IN) NOMINAL HEAT ANTICIPATOR SETTING
CONCENTRIC VENT KIT (FOR 4" FLUE RJ) CONCENTRIC VENT KIT (FOR 5" FLUE RJ) DUAL PIPE FLASHING KIT BAYVENT SIDE WALL VENT KIT SLOPE ADAPTER 2-1/2 / 12 SLOPE ADAPTER 3-1/2 / 12 MINI CONDENSATE PUMP KIT NEUTRALIZING KIT

CMC2-50D36 (DV3)

50,000

48,000

95%

3 TONS

NAT

LP

#42

#54

CMC2-75D36 (DV3)

75,000

72,000

95%

3 TONS

NAT

LP

#42

#54

4.5

11

4.5

11

14

14

14

14

3.5±0.3

10±0.3

3.5±0.3

10±0.3

55º

65º

2" PVC

2" PVC

76 1/8"

76 1/8"

18 3/4"

18 3/4"

25 3/4"

25 3/4"

195 LBS.

205 LBS.

ETL

ETL

18" X 24"

18" X 24"

115 VAC/ 60 HZ/ 1 PHASE

115 VAC/ 60 HZ/ 1 PHASE

15 AMPS

15 AMPS

7.15

7.15

12" X 12"

12" X 12"

0.8mA

0.8mA

ACCESSORY ITEMS

AOPS7483

AOPS7483

AOPS7544

AOPS7544

AOPS7484

AOPS7484

370191

370191

TSA-25

TSA-25

TSA-30

TSA-30

AOPS7614

AOPS7614

320095

320095

1 OUTPUT BTUH BASED ON ANNUAL FUEL UTILIZATION EFFICIENCY RATED BY MANUFACTURER. 2 SEASONAL EFFICIENCY (ALSO CALLED AFUE-ANNUAL FUEL UTILIZATION EFFICIENCY) RATINGS ARE BASED ON TEST FOLLOWING U.S. DEPARTMENT OF ENERGY TEST PROCEDURES. 3 TO PERMIT LARGEST RECOMMENDED AIR CONDITIONING (AT .5 STATIC PRESSURE), SELECTION OF THE HIGHEST MOTOR SPEED IS REQUIRED.

PS040010 ECN 5580-MA
22

Air Handlers with Optional Hydronic Heating Coils
The Thermo Pride air handlers are designed to be used as a stand-alone cooling, stand-alone heating or combination heating and cooling air handler. The air handlers can be installed in a upflow or horizontal applications. The cooling coil comes factory installed. In heating mode, our air handler provides up to 70° temperature rise (at 180°F entering water temperature), which provides warmer air than many air handlers on the market. All units operate on 115V and coils use 410A refrigerant. Our air handler requires little maintenance and provides efficiency, longevity, and worry-free comfort. It also comes with our standard 10-year coil and 5-year parts warrany.
23

MODEL SERIES DESCRIPTION BURNER BTU OUTPUT
HEIGHT OF CASING WIDTH OF CASING DEPTH OF CASING WARM AIR OUTLET (WxD) RETURN AIR INLET (WxD) DIAMETER OF FLUE FLOOR TO CENTER OF FLUE
BLOWER MOTOR
CFM @ 0.2 & 0.5 W.C.
STANDARD LOW SPEED ML SPEED MED. SPEED MH SPEED HIGH SPEED
A/C CAPACITY
BECKETT NOZZLE SIZE GPH CARLIN NOZZLE SIZE GPH SPRAY ANGLE/PATTERN PUMP PRESSURE

VHF-ABP
HIGHBOY
Beckett 60,000 / 72,000
90,000

VHF-ACP
HIGHBOY
Carlin 60,000 / 72,000
90,000

SPIRIT OIL FIRED FURNACE SPECIFICATIONS

VHF-ABT
HIGHBOY
Beckett 60,000 / 72,000
90,000

VHF-ACT
HIGHBOY
Carlin 60,000 / 72,000
90,000

VH8FA119P60B
HIGHBOY
Beckett 101,000 / 119,000
132,000

VH8FA119T60B
HIGHBOY
Beckett 101,000 / 119,000
132,000

VLF-DBP VLR-DBP
LOWBOY
Beckett 70,000 / 88,000 98,000 / 114,000

VLF-DCP VLR-DCP
LOWBOY
Carlin 70,000 / 88,000 98,000 / 114,000

VL8FA119P60B VL8RA119P60B
LOWBOY
Beckett 101,000 / 119,000
132,000

VC-CBP
HORIZONTAL/ COUNTERFLOW
Beckett
69,000 / 88,000 97,000

45" 21" 30" 19" x 19" 24" x 14 1/4" 5" 40 11/16"

45" 21" 30" 19" x 19" 24" x 14 1/4" 5" 40 11/16"

45" 21" 30" 19" x 19" 24" x 14 1/4" 5" 40 11/16"

45" 21" 30" 19" x 19" 24" x 14 1/4" 5" 40 11/16"

50 1/8" 24 1/2" 36 1/2" 20" x 20" 23-3/4" x 19"
7" 42 3/4"

50 1/8" 24 1/2" 36 1/2" 20" x 20" 23-3/4" x 19"
7" 42 3/4"

41 1/2" 22 1/4"
47" 20" x 20" 20" x 12 1/2"
6" 30 3/8"

41 1/2" 22 1/4"
47" 20" x 20" 20" x 12 1/2"
6" 30 3/8"

38 1/2" 24 1/2" 55 1/2" 20" x 20" 20" x 16"
7" 29 1/2"

61 1/4" 22 1/4" 22 1/4" 16" x 16" 16" x 16"
6 29 7/8"

1/2HP-4SPD-PSC 1/2HP-4SPD-PSC 1/2HP-5SPD-ECM 1/2HP-5SPD-ECM 3/4HP-4SPD-PSC

0.2

0.5

0.2

0.5

0.2

0.5

0.2

0.5

0.2

0.5

915 1152
1432 1762

822 1085
1334 1569

915 1152
1432 1762

822 1085
1334 1569

1012 1172 1303 1498 1650

821 1037 1205 1399 1561

1012 1172 1303 1498 1650

821 1037 1205 1399 1561

1300 1526
1874 2228

1237 1458
1746 2069

1 HP-5SPD-ECM

0.2

0.5

1429 1593 1693 1766 2185

1222 1422 1520 1596 2045

3/4HP-4SPD-PSC

0.2

0.5

CFM for Front Flue, see specs for Rear
Flue

1106

1023

1339

1216

3/4HP-4SPD-PSC

0.2

0.5

CFM for Front Flue, see specs for Rear
Flue

1106

1023

1339

1216

1 HP-4SPD-PSC,

Front Flue

3/4HP-4SPD-PSC,

Rear Flue

0.2

0.5

CFM for Front Flue, see specs for Rear
Flue

1344

1234

1611

1496

1572 1822

1376 1564

1572 1822

1376 1564

1868 2235

1710 2012

1/2HP-4SPD-PSC

0.2

0.5

1139 1274
1397 1550

1017 1111
1209 1347

4 Ton

4 Ton

4 Ton

4 Ton

5 Ton

5 Ton

4 Ton

4 Ton

5 Ton

3.5 Ton

.50 .60 .75 N/A 80° A
120 PSI

N/A .50 .60 .75
60° A 120 PSI

.50 .60 .75 N/A 80° A
120 PSI

N/A .50 .60 .75
60° A 120 PSI

.85 1.00 1.10 N/A 80° A
120 PSI

.85 1.00 1.10 N/A 80° A
120 PSI

.60 .75 .85 1.00 N/A 80° A
130 PSI

N/A .60 .75 .85 1.00
60° A 140 PSI

.85 1.00 1.10 N/A 80° A
120 PSI

.60 .75 .85 N/A 80° A
130 PSI

SHIPPING WEIGHT SEASONAL AFUE BECKETT SEASONAL AFUE CARLIN

270 LBS. 85% N/A

270 LBS. N/A 86%

270 LBS. 85% N/A

270 LBS. N/A 86%

335 LBS. 85% N/A

For complete specifications see specifications on line at www.thermopride.com/products/spiritfurnace/manuals-specifications-literature/specifications/

All specifications subject to change without notice

335 LBS. 85% N/A

305 LBS 85% N/A

305 LBS N/A 86%

345 LBS 85% N/A

300 LBS 85% N/A

Rev 120420

Scan this code with your smart phone to visit our website. www.thermopride.com


Thermo Products, LLC Healing & Air Conditioning

Thermo Products, LLC P.O. Box237
Denton, NC 27239 800-348-5130 or 800-476-4328
www.thermopride.com www.spiritfurnace.com
MS601002 Rev.050222

