Contractor Information | Thermo Pride | Built Tough For Lifetime Comfort
Support - Thermo Pride | Built Tough For Lifetime Comfort
Parts and Specification Catalog There are no prices in this book Table of Contents Thermo Pride products have been the name for high-quality, handcrafted, hometown values, and high-efficiency for 76 years. We offer a full line of oil and gas-fired warm air furnaces, coils and accessories. Product specifications may change. Please refer to www.thermopride.com for the most current product specifications. TABLE OF CONTENTS Oil Furnaces and Accessories Oil Furnaces - OH6, OL6, OD6, OH8, OL8, OT11, OT16, OL20 Oil Furnace Accessories Gas Furnaces and Accessories Gas Furnaces - CLQS1 Gas Furnace Accessories Mobile Home/Cottage Furnaces and Accessories Mobile Home/Cottage Furnaces - OME, GMD2, CMA4, CMC2 Series Mobile Home Accessories Air Conditioning Evaporator Coils AC Evaporator Coils and Cabinets Air Handlers Air Handlers with Optional Hydronic Heating Coil Plenums and Transitions Plenums and Transitions Spirit Oil Furnaces & Accessories Spirit Oil Furnaces Spirit Oil Furnace Accessories Spec Sheets OH6 Oil Highboy Specs OL6 Oil Lowboy Specs OD6 Oil Counterflow/Horizontal Specs OH8 Oil Highboy Specs OL8 Oil Lowboy Specs OL20 Oil Lowboy Specs OT11, OT16 Oil Specs CLQS1 Gas Multi-Position Specs OME Oil Mobile Home Specs GMD2 Gas Mobile Home Specs CMA4 Gas Mobile Home Specs CMC2 Gas Mobile Home Specs Air Handlers Specs Spirit Oil Spec Table - All Models Terms and Conditions Terms and Conditions PAGE NO. 2 3 4 4 5 5 6 7 8 9 9 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 1 MODEL NO. Oil Furnaces Furnace and Burner Must Be Ordered Separately Prices effective: May 2, 2022 DESCRIPTION AFUE% BECKETT/ CARLIN AFUE% RIELLO BTU/H OUTPUT SHIPPING WEIGHT 380692 380835 380693 OH6FA072D48 OH6FA072DV4 OL6FA072D48 OL6RA072D48 OL6FA072DV5 OL6RA072DV5 OD6FA072D48 OD6RA072D48 OD6FA072DV5 OD6RA072DV5 TP2501 - Beckett AFG Oil Burner for 6 Series Carlin EZ-1 Oil Burner for 6 Series Riello BF3 Oil Burner for 6 Series Low-Profile Highboy, Front Flue Low-Profile Highboy, Front Flue Lowboy, Front Flue Lowboy, Rear Flue Lowboy, Front Flue Lowboy, Rear Flue Counterflow/Horizontal, Front Flue Counterflow/Horizontal, Rear Flue Counterflow/Horizontal, Front Flue Counterflow/Horizontal, Rear Flue 86 86.1 60,000/72,000/90,000 280 86 86.1 60,000/72,000/90,000 280 86.5/86 87 60,000/72,000/90,000 315 86.5/86 87 60,000/72,000/90,000 315 86.5/86 87 60,000/72,000/90,000 315 86.5/86 87 60,000/72,000/90,000 315 85.7/85 85.7 60,000/72,000/90,000 250 85.7/85 85.7 60,000/72,000/90,000 250 85.7/85 85.7 60,000/72,000/90,000 250 85.7/85 85.7 60,000/72,000/90,000 250 380754 380836 380756 OH8FA119D60 OH8FA119DV5 OL8FA119T60 OL8RA119T60 TP2502 - Beckett AFG Oil Burner for 8 Series Carlin EZ-1 Oil Burner for 8 Series Riello BF3 Oil Burner for 8 Series Highboy, Front Flue Highboy, Front Flue Lowboy, Front Flue Lowboy, Rear Flue 85.8/85 86 101,000/120,000/132,000 390 85.8/85 86 101,000/120,000/132,000 390 85 85 101,000/119,000/132,000 315 85 85 101,000/119,000/132,000 315 380737 TP1011 - Beckett AFG Oil Burner for 11 Series ROB-11 OT11-105FBP OT11-105RBP Riello ROB-11 Oil Burner for 11 Series Horizontal, Front Flue, Exposed Burner Horizontal, Rear Flue, Exposed Burner 83 83 101,000 445 83 83 101,000 445 380738 TP1021 - Beckett AFG Oil Burner for 16 Series ROB-16 OT16-125FBP OT16-125RBP Riello ROB-16 Oil Burner for 16 Series Horizontal, Front Flue, Exposed Burner Horizontal, Rear Flue, Exposed Burner 83 83 125,000 500 83 83 125,000 500 380739 TP1031 - Beckett AFG Oil Burner for 20 Series ROB-20 OL20FA151T60 OL20RA151T60 Riello ROB-20 Oil Burner for 20 Series Lowboy, Front Flue Lowboy, Rear Flue 85 85 153,000 600 85 85 153,000 600 2 Oil Accessories Prices effective: May 2, 2022 DESCRIPTION PART NO. FURNACE or ACCESSORY MODEL SHIPPING WT. (lbs.) 4" Clean Out Assembly (Cover, Gasket, T-Bar, Nut) - Pair AOPS7586 OC2-5, OH2-16, OL2-39, OT5-16 2 Clean Out Plug Assembly - Each S00S4489 OH6, OD6F, OL6, OH8, OD6R, OME 1 D6 Base D6-BASE OD6 Counterflow Applications Only 36 D6 Cottage Base D6COT-BASE OD6 Counterflow Applications Only 46 Optional Fan Timer AOPS7433 Only used with models using a 2 combination fan limit control Combustion Air Intake Hood Kit AOPS7402 General Application 3 Combusion Air Kit PVB-2 5, 11, 16, 20 Series 14 Field Direct Vent Termination Kit (includes vent hood & 15' flexible vent pipe) AOPS8393 OH6, OL6 & OD6 41 Field Direct Vent Termination Kit (includes vent hood & 15' flexible vent pipe) AOPS8414 OH8, OL8 42 Sidewall Vent Accessory Kit for Beckett Burner* AOPS8394 OH6, OH8, OL6, OL8 & OD6 4 Sidewall Vent Accessory Kit for Beckett NX Burner* AOPS8412 OH6 4 Sidewall Vent Accessory Kit for Riello Burner* AOPS8395 OH6, OH8, OL6, OL8 & OD6 3 Sidewall Vent Accessory Kit for Carlin Burner* AOPS8432 OH6, OH8, OL6, OL8 & OD6 3 Blocked Vent Switch (Canadian Applications) 350156 All Oil 2 Combustion Air Kit for combustion air only w/Beckett AF/AFG burner AOPS8397 OH8, OH6, OD6, OL5, OL6, OL8 6 Combustion Air Kit for combustion air only w/ Beckett NX Burner AOPS8413 OH6 6 Combustion Air Kit for combustion air only w/Riello Burner AOPS8416 OH6, OH8, OL6, OL8 & OD6 6 Combustion Air Kit for combustion air only w/Carlin Burner AOPS8433 OH6, OH8, OL6, OL8 & OD6 3 2 Line System Kit for Riello 380705 Used on BF3/BF5 burner 1 Filter Rack, 16 x 25 in., takes 1" filter AOPS7547 OH5, OH6, OH11 6 Filter Rack, 20 x 20 in. AOPS8385 General Use 4 Filter Rack, 20 x 25 in. AOPS8386 General Use 4 Filter Rack, 20 x 25 x 6 in. AOPS7375 OH8, OH16 4 #5F Replacement Chamber w/rock wool and gaskets AOPS7323 5, 11 Series 11 #16F Replacement Chamber w/rock wool and gaskets AOPS7324 16, 20 Series 14 Note: Blower conversion kits available. Please call customer service with model number and serial number for pricing and availability. *Required when using Field Direct Vent Termination Kit 3 Gas Furnaces Prices effective: May 2, 2022 MODEL NO. AFUE% MAXIMUM A/C CAPACITY (tons) BTU/H INPUT SHIPPING WT. (lbs.) GAS SINGLE-STAGE CONDENSING MULTI-POSITION MODELS (Upflow, Downflow, Horizontal) HIGH EFFICIENCY CONSTANT TORQUE ECM BLOWER MOTOR CLQS1-050T36N 95 3 50,000 155 CLQS1-075T42N 95 3.5 75,000 166 CLQS1-100T48N 95 4 100,000 183 CLQS1-125T60N 95 5 125,000 196 All above gas furnaces supplied as natural gas with a propane kit included. For Energy Star qualified units, go to www.energystar.gov. GAS ACCESSORIES DESCRIPTION Concentric Vent Kit - 2" Concentric Vent Kit - 3" Sidewall Vent Cap LP Conversion Kit Nat. Conversion Kit Neutralizer Kit Mini Condensate Pump 50CLQ Base 125CLQ Base PART NO. AOPS7488 AOPS7489 370191 AOPS7749 AOPS7745 320095 AOPS7614 50CLQ-Base 125CLQ-Base FURNACE CLQS1-050, 075 CLQS1-100, 125 CLQS1 CLQS1 CLQS1 CLQS1 CLQS1 CLQS1-050 CCLQS1-075, 100, 125 SHIPPING WT. (lbs.) 11 11 2 1 1 6 5 15 18 CHX3, CDX3, CHB1, CDB1, CMA, CMC, CLHS1, CLQS1 4 Mobile Home/Cottage Furnaces Accessories Prices effective: May 2, 2022 MODEL NO. AFUE% BTU/H OUTPUT SHIPPING WT. (lbs.) OIL MOBILE HOME/COTTAGE FURNACES OME-72D36 (with PSC blower motor and Beckett AFG Burner) 86 60,000/72,000 OME-72T36 (with ECM blower motor and Beckett AFG Burner) 86 60,000/72,000 GMD2-60N GMD2-80N CMA4-50D36N CMA4-75D36N GAS MOBILE HOME/COTTAGE FURNACES 81.6 50,000 81 65,000 95 48,000 95 72,000 CMC2-50D36N with PSC blower motor and integrated coil cabinet 95 48,000 CMC2-75D36N with PSC blower motor and integrated coil cabinet 95 72,000 CMC2-50DV3N with ECM blower motor and integrated coil cabinet 95 48,000 CMC2-75DV3N with ECM blower motor and integrated coil cabinet 95 72,000 DESCRIPTION 70-Base Cottage Base 4" Stainless Steel Vent Pipe (34" long) 1' Roof Jack 2' Roof Jack 3' Roof Jack Slope Adapter for roof pitch 2-1/2"--12" Slope Adapter for roof pitch 3-1/2"--12" 2" Concentric Vent Kit with 4" Adapter for 4" Roof Jack 2" Concentric Vent Kit with 5" Adapter for 5" Roof Jack Dual Pipe Flashing Kit Combustion Air Intake Hood Roof Jack Combustion Air Kit Flexible Stainless Steel Offset Vent Kit High Altitude Orifice Kit - 2001-4500 ft High Altitude Orifice Kit - 4501-6500 ft High Altitude Orifice Kit - 6501-8500 ft GMD1-80N Upgrade Blower Kit for 3 Ton AC Neutralizing Kit Mini Condensate Pump Transition Boot with Screen MOBILE HOME ACCESSORIES PART NO. 70-BASE 01COT-BASE VP-1 TRJ-1 TRJ-2 TRJ-3 TSA-25 TSA-30 AOPS7483 AOPS7544 AOPS7484 AOPS7402 AOPS7512 AOPS7518 AOPS7732 AOPS7733 AOPS7734 AOPS2677 320095 AOPS7614 AOPS8419 FURNACE or ACCESSORY MODEL OME, GMD, CMA OME, GMD, CMA OME, GMD OME, GMD OME, GMD OME, GMD OME, GMD, CMA, CMC OME, GMD, CMA, CMC CMA, CMC CMA, CMC CMA, CMC OME, GMD OME OME, GMD CMA, CMC CMA, CMC CMA, CMC GMD1-80 CMA, CMC CMA, CMC OME, GMD 210 210 185 185 185 185 220 220 220 220 SHIPPING WT. (lbs) 25 35 6 30 30 36 8 8 20 12 10 3 16 3 1 1 1 42 6 3 6 5 AC Evaporator Coils and Cabinets Prices effective: May 2, 2022 *All coils come with TXV suitable for AC & HP applications* THERMO PRIDE COLOR-MATCHED CASED COILS FOR UPFLOW FURNACES CASED COIL MODEL NO. HE33936PA212 HE47936PA212 HE50960PA212 CABINET DIM. W X D X H (in.) 21.25 X 21.25 X 19 21.25 X 21.25 X 29 21.25 X 21.25 X 29 PLENUM OPENING W X D (in.) 19.8 X 19.8 19.8 X 19.8 19.8 X 19.8 SHIPPING WEIGHT (lbs.) 50 72 72 CABINET NO. CE112S CE312T CE215T CE216T CE217T DOWNFLOW CABINET APPLICATIONS FURNACE APPLICATION OD6 Downflow OD6 Downflow CLQS1-050 CLQS1-075, 100, 125 CLQS1-125 CABINET DIMENSIONS W X D X H (in.) 20 X 30 X 18 23.25 X 30 X 29.5 17.75 X 27.8 X 18.5 21.25 X 27.8 X 28.5 24.75 X 27.8 X 28.5 Uncased Coil Part No. (See Uncased Coil Pricing Below) HE33936UA170 HE47936UA205 HE50960UA205 HE33936UA170 HE33936UA200 HE50960UA205 HE47936UA205 HE33936UA200 HE50960UA205 HE47936UA205 SHIPPING WEIGHT (lbs.) 36 48 30 42 44 MOBILE HOME CABINET APPLICATONS CABINET NO. CE111S FURNACE APPLICATION OME, GMD, CMA CABINET DIMENSIONS W X D X H (in.) 18.75 X 24.75 X 20 Uncased Coil Part No. (See Uncased Coil Pricing Below) HE33936UA170 SHIPPING WEIGHT (lbs.) 35 YOU MUST ORDER THE CABINET AND COIL SEPARATELY FOR THE APPLICATIONS ABOVE. THE CABINETS ABOVE ARE FOR USE WITH UNCASED COILS ONLY. COILS NOT INCLUDED WITH CABINET. SEE BELOW FOR UNCASED COIL PRICE. UNCASED COILS UNCASED COIL MODEL NO. HE33936UA170 HE33936UA200 HE47936UA205 HE50960UA205 TONS 2 to 3 2 to 3 2 to 3 3.5 to 5.0 DIMENSIONS W X D X H (in.) 17 X 19.5 X 17 20 X 19.5 X 17 20.5 X 19.5 X 27 20.5 X 19.5 X 27 SHIPPING WEIGHT (lbs.) 32 32 50 50 All Thermo Pride coils are made by ADP and use the same model numbers that match with many other condenser manufactures. Please visit www.ahridirectory.org to match a Thermo Pride coil with one of those many condensers. 6 Air Handlers with Optional Hydronic Heating Coils Prices effective: May 2, 2022 The Advantage of our Air Handler System The Thermo Pride air handlers are designed to be used as a stand-alone cooling, stand-alone heating or combination heating and cooling air handler. The air handlers can be installed in a upflow or horizontal applications. The cooling coil comes factory installed. In heating mode, our air handler provides up to 70° temperature rise (at 180°F entering water temperature), which provides warmer air than many air handlers on the market. All units operate on 115V and coils use 410A refrigerant. Our air handler requires little maintenance and provides efficiency, longevity, and worry-free comfort. It also comes with our standard 10-year coil and 5-year parts warrany. MODEL NO. COOLING BTU/H CAPACITY COMPONENTS AH2436AE1 (cabinet with factory installed A/C coil) 2-3 Ton, 115V, ECM Blower Motor HC1-B (Hydronic Coil), Inlet Temperature Range (F) 140-180 UA1-C (Upflow Adapter Cabinet) 1 24,000-36,000 -- HEATING BTU/H OUTPUT 2 SHIPPING WT. (lbs.) -- 130 32,000-75,000 21 -- 43 AH4260AE1 (cabinet with factory installed A/C coil) 3.5-5.0 Tons 36,000-60,000 -- 180 HC2-A (Hydronic Coil), Inlet Temperature Range (F) 140-180 -- 55,000-120,000 34 UA2-C (Upflow Adapter Cabinet) 1 -- 48 1 Return base including filter rack for upflow applications 2 Based on 180°F boiler water temperature and 7 GPM circulator 7 Plenums and Transitions FURNACE MODEL PART NO. DIMENSIONS WxDxH (in.) OH6 AH4260AE1, OH8, OL6, OT11, VH8, VL8, VLR, VLF, CLQS1-075T42N, 100T48N, 125T60N SUPPLY PLENUMS PK181X191 18 x 19 x 36 PK202X202 20 x 20 x 36 CLQS1-050T36N OD6 OT16 VC VHF PK164X202 14 x 20 x 36 PK181X201 18 x 20 x 36 PK201X221 20 x 22 x 36 PK163X163 16 x 16 x 36 PK192X192 19 x 19 x 36 RETURN PLENUMS OL6 VL8 OT11 OT16 OD6 VC VLR, VLF PK181X201 PK161X201 PK202X202 PK201X221 PK181X191 PK163X163 PK126X202 18 x 20 x 36 20 x 16 x 36 20 x 20 x 36 20 x 22 x 36 18 x 19 x 36 16 x 16 x 36 12-1/2 x 20 x 36 TRANSITIONS OH6, VHF PT1819X2020 N/A Transition from 18 x 19 plenum flanges to 20 x 20 6" high, includes S-Locks Prices effective: May 2, 2022 RETURN BOOT AND DROP KIT OH6, VHF, CLQS1-050T, 075T, 100T RD2510X2516 N/A Fits factory supplied optional filter rack (25 x 16), includes 25 x 10 x 60 drop, 90 degree boot and flexible starting collar OH8, VH8, CLQS1-125T60N RD2512X2520 N/A Fits factory supplied optional filter rack (25 x 20), includes 25 x 12 x 60 drop, 90 degree boot and flexible starting collar Note: Plenums ship knocked down 8 Spirit Oil Furnaces Prices effective: May 2, 2022 MODEL NO. AFUE% BTU/H OUTPUT SHIPPING WT. (lbs.) OIL LOW PROFILE HIGHBOY FURNACES PSC DIRECT DRIVE BLOWER MOTOR VHF-ABP (with Beckett AFG) 85 VHF-ACP (with Carlin EZ-1HP) 86 CONSTANT TORQUE ECM BLOWER MOTOR 60,000/72,000/90,000 240 60,000/72,000/90,000 240 VHF-ABT (with Beckett AFG)* VHF-ACT (with Carlin EZ-1HP)* * Energy Star Qualified 85 60,000/72,000/90,000 275 86 60,000/72,000/90,000 275 OIL HIGHBOY FURNACES PSC DIRECT DRIVE BLOWER MOTOR WITH BECKETT AFG BURNER VH8FA119P60B 85 101,000/119,000/132,000 335 ECM BLOWER MOTOR WITH BECKETT AFG BURNER VH8FA119T60B * * Energy Star Qualified 85 101,000/119,000/132,000 335 OIL LOWBOY FURNACES (Higher Capacity) PSC DIRECT DRIVE BLOWER MOTOR VLF-DBP (Front Flue with Beckett AFG) 85 70,000/88,000/98,000/114,000 305 VLR-DBP (Rear Flue with Beckett AFG) 85 70,000/88,000/98,000/114,000 305 VLF-DCP (Front Flue with Carlin EZ-1HP) 86 70,000/88,000/98,000/114,000 305 VLR-DCP (Rear Flue with Carlin EZ-1HP) 86 70,000/88,000/98,000/114,000 305 HIGH CAPACITY VL8FA119P60B (front flue) VL8RA119P60B (rear flue) 85 101,000/119,000/132,000 345 85 101,000/119,000/132,000 345 OIL COUNTERFLOW / HORIZONTAL FURNACES PSC DIRECT DRIVE BLOWER MOTOR WITH BECKETT AFG BURNER VC-CBP 85 69,000/88,000/97,000 300 ACCESSORIES DESCRIPTION PART NO. FURNACE SHIPPING WT. (lbs.) Combustible Floor Base VC-Base VC-CBP 23 4 Ton Upgrade Blower Kit S00S4140 VC-CBP 44 4 Ton Upgrade Blower Kit S00S4141 VLF-CBP, VLR-CBP 44 Field Direct Vent Termination Kit (includes vent hood & 15' flexible vent pipe) for Beckett and Carlin AOPS8393 VHF-AB*, VHF-AC* 41 Field Direct Vent Termination Kit (includes vent hood & 15' flexible vent pipe) AOPS8414 VH8, VL8 42 Sidewall Vent Accessory Kit for Beckett Burner (Required when using Field Direct Vent Termination AOPS8394 VHF-AB*, VH8, VL8 4 Kits above.) Sidewall Vent Accessory Kit for Carlin Burner (Required when using Field Direct Vent AOPS8432 VHF-AC* 3 Termination Kits above.) Blocked Vent Switch for (Canadian Applications) 350156 All Models 2 Combustion Air Kit for Beckett AFG Burner for Combustion Air Kit for Carlin EZ-1 Burner Combustion Air Kit for combustion air only AOPS8397 VHF-AB*, VH8, VL8 6 AOPS8433 VHF-AC* 6 AOPS7482 VL*-CBP, VL*-DBP, VL*-DCP, VC-CBP 6 For Energy Star qualified units, go to www.energystar.gov. 9 Spec Sheets Full specifications and manuals are available online at www.thermopride.com. Scan for all Current and Discontinued Specifications 10 OIL FIRED UPFLOW FURNACE SPECIFICATIONS MODEL NO. OH6FA072D48 / DV4 B OH6FA072D48 / DV4 R OH6FA072D48 / DV4 C HEATING CAPACITY HEAT INPUT RATE (BTUH) OUTPUT BTUH1 SEASONAL EFFICIENCY2 LARGEST REC A/C3 NOMINAL TEMP RISE HEAT EXCHANGER AREA CASING HEIGHT (IN.): CASING WIDTH (IN.): CASING DEPTH (IN.): NOMINAL FLUE OUTLET DIA. APPROX SHIPPING WEIGHT LBS APPROVAL STANDARDS QTY AND SIZE OF PERMANENT FILTERS ELECTRICAL REQUIREMENTS VAC/HZ/PH MAX FUSE SIZE (AMPS) PSC/ECM TOTAL CURRENT (AMPS) PSC/ECM HEIGHT FROM FLOOR TO CENTER OF FLUE High Fire 106,250 89,000 66 Med Fire 85,000 72,000 86.0% 4 Tons 66 Low Fire High Fire 70,000 106,250 60,000 90,000 66 66 Med Fire 85,000 73,000 86.1% 4 Tons 66 Low Fire 70,000 60,000 66 High Fire 106,250 90,000 66 Med Fire 85,000 71,000 86.0% 4 Tons 66 Low Fire 70,000 60,000 66 45" 20" 30" 5" 250 UL727 CAN/CSA B140.4 (1) 24 3/4" X 15 3/4" 120/60/1 15 / 15 8.7 / 12.1 40 3/4" 45" 20" 30" 5" 250 UL727 CAN/CSA B140.4 (1) 24 3/4" X 15 3/4" 120/60/1 15 / 15 8.7 / 12.1 40 3/4" 45" 20" 30" 5" 250 UL727 CAN/CSA B140.4 (1) 24 3/4" X 15 3/4" 120/60/1 15 / 15 8.7 / 12.1 40 3/4" SUPPLY AIR OUTLET SIZE (W-IN. X D-IN.) 18" X 19" (20" X 20")5 18" X 19" (20" X 20")5 18" X 19" (20" X 20")5 RETURN AIR DUCTWORK CONNECTION FLANGE SIZE ON FILTER RACK (D-IN. X H-IN.) RETURN AIR INLET OPENING SIZE IN SIDE CASING (TO BE CUTOUT BY DEALER) (D-IN. X H-IN.) 2-LINE SYSTEM KIT FOR RIELLO COMBUSTION AIR KIT FIELD VENT TERMINATION KIT SIDEWALL VENT ACCESSORIES KIT BLOCKED VENT KIT4 OIL BURNER SUPPLY PLENUM RETRUN BOOT & DROP KIT CASED COIL 2-3 TON CASED COIL 2-3 TON HIGH EFF. CASED COIL 3.5-4 TON 24 1/2" X 15" 23" X 14" N/A AOPS8397 AOPS8393 AOPS8394 AOPS2686 BECKETT AFG (380692) PK181X191 RD2510X2516 HE33936PA212 HE47936PA212 HE50960PA212 24 1/2" X 15" 23" X 14" ACCESSORY ITEMS 380705 AOPS8416 AOPS8393 AOPS8395 AOPS2686 RIELLO BF3 (380693) PK181X191 RD2510X2516 HE33936PA212 HE47936PA212 HE50960PA212 24 1/2" X 15" 23" X 14" N/A AOPS8433 AOPS8393 AOPS8432 AOPS2686 CARLIN EZ-1HP (380835) PK181X191 RD2510X2516 HE33936PA212 HE47936PA212 HE50960PA212 1 OUTPUT BTUH BASED ON ANNUAL FUEL UTILIZATION EFFICIENCY RATED BY MANUFACTURER. 2 SEASONAL EFFICIENCY (ALSO CALLED AFUE - ANNUAL FUEL UTILIZATION EFFICIENCY) RATINGS ARE BASED ON TESTS FOLLOWING U.S. DEPARTMENT OF ENERGY TEST PROCEDURES. 3 TO PERMIT LARGEST RECOMMENDED AIR CONDITIONING (AT .5 STATIC PRESSURE), SELECTION OF THE HIGHEST MOTOR SPEED IS REQUIRED. 4 NOT TO BE USED IN SIDEWALL VENT APPLICATIONS, USE ONLY WHEN CHIMNEY VENTED. 5 PLENUM ADAPTERS INCLUDED WITH UNIT MUST BE INSTALLED FOR 20"x20" PLENUM. PS020001 11 ECN 5713-MA 220406 OIL FIRED UPFLOW FURNACE SPECIFICATIONS MODEL NO. HEATING CAPACITY HEAT INPUT RATE (BTUH) OUTPUT BTUH1 SEASONAL EFFICIENCY2 LARGEST REC A/C3 NOMINAL TEMP RISE HEAT EXCHANGER AREA CASING HEIGHT (IN.): CASING WIDTH (IN.): CASING DEPTH (IN.): NOMINAL FLUE OUTLET DIA. APPROX SHIPPING WEIGHT LBS APPROVAL STANDARDS QTY AND SIZE OF PERMANENT FILTERS OL6*A072D48/DV5 B OL6*A072D48/DV5 R OL6*A072D48/DV5 C High Fire Med Fire Low Fire 106,250 85,000 70,000 89,000 72,000 60,000 86.5% 4 Tons / 5 Tons 66 66 66 High Fire Med Fire Low Fire 106,250 85,000 70,000 90,000 73,000 60,000 87.0% 4 Tons / 5 Tons 66 66 66 High Fire Med Fire Low Fire 106,250 85,000 70,000 89,000 72,000 60,000 86.0% 4 Tons / 5 Tons 66 66 66 34-3/4" 20" 50" 5" 250 UL727 CAN/CSA B140.4 (2) 19-3/4" X 13-3/4" 34-3/4" 20" 50" 5" 250 UL727 CAN/CSA B140.4 (2) 19-3/4" X 13-3/4" 34-3/4" 20" 50" 5" 250 UL727 CAN/CSA B140.4 (2) 19-3/4" X 13-3/4" ELECTRICAL REQUIREMENTS VAC/HZ/PH MAX FUSE SIZE (AMPS) PSC/ECM TOTAL CURRENT (AMPS) PSC/ECM 120/60/1 15 / 15 8.7 / 12.3 120/60/1 15 / 15 8.7 / 12.3 120/60/1 15 / 15 8.7 / 12.3 HEIGHT FROM FLOOR TO CENTER OF FLUE 28-3/8" 28-3/8" 28-3/8" SUPPLY AIR OUTLET SIZE (W-IN. X D-IN.) RETURN AIR INLET OPENING SIZE (W-IN. X D-IN.) 2-LINE SYSTEM KIT FOR RIELLO COMBUSTION AIR KIT FIELD VENT TERMINATION KIT SIDEWALL VENT ACCESSORIES KIT BLOCKED VENT KIT4 OIL BURNER SUPPLY PLENUM RETRUN PLENUM CASED COIL 2-3 TON CASED COIL 2-3 TON HIGH EFF. CASED COIL 3.5-5 TON 18" X 20" (20" X 20")5 18" X 18" (20" X 18")5 N/A AOPS8397 AOPS8393 AOPS8394 AOPS2686 BECKETT AFG (380692) PK202X202 PK181X201 HE33936PA212 HE47936PA212 HE50960PA212 18" X 20" (20" X 20")5 18" X 18" (20" X 18")5 ACCESSORY ITEMS 380705 AOPS8416 AOPS8393 AOPS8395 AOPS2686 RIELLO BF3 (380693) PK202X202 PK181X201 HE33936PA212 HE47936PA212 HE50960PA212 18" X 20" (20" X 20")5 18" X 18" (20" X 18")5 N/A AOPS8433 AOPS8393 AOPS8432 AOPS2686 CARLIN EZ-1HP (380835) PK202X202 PK181X201 HE33936PA212 HE47936PA212 HE50960PA212 1 OUTPUT BTUH BASED ON ANNUAL FUEL UTILIZATION EFFICIENCY RATED BY MANUFACTURER. 2 SEASONAL EFFICIENCY (ALSO CALLED AFUE - ANNUAL FUEL UTILIZATION EFFICIENCY) RATINGS ARE BASED ON TESTS FOLLOWING U.S. DEPARTMENT OF ENERGY TEST PROCEDURES. 3 TO PERMIT LARGEST RECOMMENDED AIR CONDITIONING (AT .5 STATIC PRESSURE), SELECTION OF THE HIGHEST MOTOR SPEED IS REQUIRED. 4 NOT TO BE USED IN SIDEWALL VENT APPLICATIONS, USE ONLY WHEN CHIMNEY VENTED. 5 PLENUM ADAPTERS, INCLUDED WITH UNIT, MUST BE INSTALLED FOR 20" PLENUM WIDTH. PS020017 12 ECN 5713-MA 220406 OIL FIRED COUNTERFLOW/*HORIZONTAL FURNACE SPECIFICATIONS MODEL NO. HEATING CAPACITY HEAT INPUT RATE (BTUH) OUTPUT BTUH1 SEASONAL EFFICIENCY2 LARGEST REC A/C3 NOMINAL TEMP RISE HEAT EXCHANGER AREA CASING HEIGHT (IN.): CASING WIDTH (IN.): CASING DEPTH (IN.): NOMINAL FLUE OUTLET DIA. APPROX SHIPPING WEIGHT LBS APPROVAL STANDARDS QTY AND SIZE OF PERMANENT FILTERS OD6F/RA072D48(V5)B OD6F/RA072D48(V5)R OD6F/RA072D48(V5)C High Fire Med Fire Low Fire High Fire Med Fire Low Fire High Fire Med Fire Low Fire 106,250 85,000 70,000 106,250 85,000 70,000 106,250 85,000 70,000 89,000 72,000 60,000 85.7% 4 Tons (5 Tons) 66 66 66 89,000 72,000 60,000 85.7% 4 Tons (5 Tons) 66 66 66 89,000 72,000 60,000 85.0% 4 Tons (5 Tons) 66 66 66 45" 20" 30" 5" 250 UL727 CAN/CSA B140.4 (2) 18-3/4" X 12-3/4" 45" 20" 30" 5" 250 UL727 CAN/CSA B140.4 (2) 18-3/4" X 12-3/4" 45" 20" 30" 5" 250 UL727 CAN/CSA B140.4 (2) 18-3/4" X 12-3/4" ELECTRICAL REQUIREMENTS VAC/HZ/PH MAX FUSE SIZE (AMPS) PSC/ECM TOTAL CURRENT (AMPS) PSC/ECM HEIGHT FROM FLOOR TO CENTER OF FLUE (F/R) SUPPLY AIR OUTLET SIZE (W-IN. X D-IN.) RETURN AIR INLET OPENING SIZE (W-IN. X D-IN.) 120/60/1 15 / 15 8.7 / 12.3 20-1/2" / 20-1/2" 18" X 20" 18" X 19" 2-LINE SYSTEM KIT FOR RIELLO COMBUSTION AIR KIT FIELD VENT TERMINATION KIT SIDEWALL VENT ACCESSORIES KIT COM BUSTIBLE FLOOR BASE COTTAGE BASE COIL CABINET BLOCKED VENT KIT4 OIL BURNER SUPPLY PLENUM RETURN PLENUM COUNTERFLOW CABINET / COIL 2-3TON CABINET / COIL 2-3TON HIGH EFF. CABINET / COIL 3.5-5 TON HORIZONTAL CASED COIL 2-3TON CASED COIL 2-3TON HIGH EFF. CASED COIL 3.5-5 TON N/A AOPS8397 AOPS8393 AOPS8394 D6-BA SE D6COT-BASE CE112S, CE312T AOPS2686 BECKETT AFG (380692) PK181X201 PK181X191 CE112S / HE33936UA170 CE312T / HE47936UA205 CE312T / HE50960UA205 HE33936CH210 HE47936CH210 HE50960CH210 120/60/1 15 / 15 8.7 / 12.3 20-1/2" / 20-1/2" 18" X 20" 18" X 19" ACCESSORY ITEMS 380705 A OPS8416 A OPS8393 A OPS8395 D6-BASE D6COT-BASE CE112S, CE312T A OPS2686 RIELLO BF3 (380693) PK181X201 PK181X191 CE112S / HE33936UA170 CE312T / HE47936UA205 CE312T / HE50960UA205 HE33936CH210 HE47936CH210 HE50960CH210 120/60/1 15 / 15 8.7 / 12.3 20-1/2" / 20-1/2" 18" X 20" 18" X 19" N/A AOPS8433 AOPS8393 AOPS8432 D6-BA SE D6COT- BA SE CE112S, CE312T AOPS2686 CARLIN EZ-1HP (380835) PK181X201 PK181X191 CE112S / HE33936UA170 CE312T / HE47936UA205 CE312T / HE50960UA205 HE33936CH210 HE47936CH210 HE50960CH210 *Horizontal installation for left or right supply. 1 OUTPUT BTUH BASED ON ANNUAL FUEL UTILIZATION EFFICIENCY RATED BY MANUFACTURER. 2 SEASONAL EFFICIENCY (ALSO CALLED AFUE - ANNUAL FUEL UTILIZATION EFFICIENCY) RATINGS ARE BASED ON TESTS FOLLOWING U.S. DEPARTMENT OF ENERGY TEST PROCEDURES. 3 TO PERMIT LARGEST RECOMMENDED AIR CONDITIONING (AT .5 STATIC PRESSURE), SELECTION OF THE HIGHEST MOTOR SPEED IS REQUIRED. 4 NOT TO BE USED IN SIDEWALL VENT APPLICATIONS, USE ONLY WHEN CHIMNEY VENTED. PS020004 13 ECN 5753143-MA 21290490260 OIL FIRED UPFLOW FURNACE SPECIFICATIONS MODEL NO. OH8FA119D60/DV5B OH8FA119D60/DV5R OH8FA119D60/DV5C HEATING CAPACITY HEAT INPUT RATE (BTUH) OUTPUT BTUH1 SEASONAL EFFICIENCY2 LARGEST REC A/C3 NOMINAL TEMP RISE High Fire 156,250 132,000 66 Med Fire 140,000 120,000 85.8% 5 Tons 66 Low Fire High Fire 119,000 156,250 101,000 132,000 66 66 Med Fire 140,000 120,000 86.0% 5 Tons 66 Low Fire 119,000 101,000 66 High Fire 156,250 132,000 66 Med Fire 140,000 120,000 85.0% 5 Tons 66 Low Fire 119,000 101,000 66 HEAT EXCHANGER AREA CASING HEIGHT (IN.): CASING WIDTH (IN.): CASING DEPTH (IN.): NOMINAL FLUE OUTLET DIA. APPROX SHIPPING WEIGHT LBS APPROVAL STANDARDS QTY AND SIZE OF PERMANENT FILTERS 50 1/8" 24 1/2" 36 1/2" 7" 310 UL727 CAN/CSA B140.4 (1) 24 3/4" X 19 3/4" 50 1/8" 24 1/2" 36 1/2" 7" 310 UL727 CAN/CSA B140.4 (1) 24 3/4" X 19 3/4" 50 1/8" 24 1/2" 36 1/2" 7" 310 UL727 CAN/CSA B140.4 (1) 24 3/4" X 19 3/4" ELECTRICAL REQUIREMENTS VAC/HZ/PH MAX FUSE SIZE (AMPS) PSC/ECM TOTAL CURRENT (AMPS) PSC/ECM 120/60/1 20/20 120/60/1 20/20 120/60/1 20/20 HEIGHT FROM FLOOR TO CENTER OF FLUE 42 1/2" 42 1/2" 42 1/2" SUPPLY AIR OUTLET SIZE (W-IN. X D-IN.) 20" X 20" 20" X 20" 20" X 20" RETURN AIR DUCTWORK CONNECTION FLANGE SIZE ON FILTER RACK (D-IN. X H-IN.) RETURN AIR INLET OPENING SIZE IN SIDE CASING (TO BE CUTOUT BY DEALER) (D-IN. X H-IN.) 23 3/4" X 19" 23" X 14" 23 3/4" X 19" 23" X 14" 23 3/4" X 19" 23" X 14" OPTIONAL REAR RETURN AIR OPENING (DIN X H-IN) 22" X 14" 22" X 14 22" X 14 2-LINE SYSTEM KIT FOR RIELLO FIELD VENT TERMINATION KIT5 SIDEWALL VENT ACCESSORIES KIT5 COMBUSTION AIR KIT BLOCKED VENT SWITCH4 OIL BURNER N/A AOPS8414 AOPS8394 AOPS8397 350156 BECKETT AFG ACCESSORY ITEMS 380705 AOPS8414 AOPS8395 AOPS8416 350156 RIELLO BF5 N/A N/A N/A N/A 350156 CARLIN EZ-1HP 1 OUTPUT BTUH BASED ON ANNUAL FUEL UTILIZATION EFFICIENCY RATED BY MANUFACTURER. 2 SEASONAL EFFICIENCY (ALSO CALLED AFUE - ANNUAL FUEL UTILIZATION EFFICIENCY) RATINGS ARE BASED ON TESTS FOLLOWING U.S. DEPARTMENT OF ENERGY TEST PROCEDURES. 3 TO PERMIT LARGEST RECOMMENDED AIR CONDITIONING (AT .5 STATIC PRESSURE), SELECTION OF THE HIGHEST MOTOR SPEED IS REQUIRED. 4 NOT TO BE USED IN SIDEWALL VENT APPLICATIONS, USE ONLY WHEN CHIMNEY VENTED. 5 NOT TO BE USED WITH CARLIN BURNER. PS020003 14 ECN 5583-MA 190617 OIL FIRED UPFLOW FURNACE SPECIFICATIONS MODEL NO. HEATING CAPACITY HEAT INPUT RATE (BTUH) OUTPUT BTUH1 SEASONAL EFFICIENCY2 LARGEST REC A/C3 NOMINAL TEMP RISE HEAT EXCHANGER AREA CASING HEIGHT (IN.): CASING WIDTH (IN.): CASING DEPTH (IN.): NOMINAL FLUE OUTLET DIA. APPROX SHIPPING WEIGHT LBS APPROVAL STANDARDS QTY AND SIZE OF PERMANENT FILTERS ELECTRICAL REQUIREMENTS VAC/HZ/PH MAX FUSE SIZE (AMPS) TOTAL CURRENT (AMPS) OL8*A119T60 B OL8*A119T60 R OL8*A119T60 C High Fire Med Fire Low Fire High Fire Med Fire Low Fire High Fire Med Fire Low Fire 156,250 140,000 119,000 156,250 140,000 119,000 156,250 140,000 119,000 132,000 67 119,000 85.0% 5 Tons 67 101,000 67 132,000 67 119,000 85.0% 5 Tons 67 101,000 67 132,000 67 119,000 85.0% 5 Tons 67 101,000 67 37-1/2" 24-1/2" 55-1/2" 7" 315 UL727 (2) 11-3/4" X 21-3/4" 120/60/1 20 16 37-1/2" 24-1/2" 55-1/2" 7" 315 UL727 (2) 11-3/4" X 21-3/4" 120/60/1 20 16 37-1/2" 24-1/2" 55-1/2" 7" 315 UL727 (2) 11-3/4" X 21-3/4" 120/60/1 20 16 HEIGHT FROM FLOOR TO CENTER OF FLUE 30-1/4" 30-1/4" 30-1/4" SUPPLY AIR OUTLET SIZE (W-IN. X D-IN.) RETURN AIR INLET OPENING SIZE (W-IN. X D-IN.) 2-LINE SYSTEM KIT FOR RIELLO COMBUSTION AIR INTAKE HOOD KIT FIELD VENT TERMINATION KIT SIDEWALL VENT ACCESSORIES KIT OIL BURNER 20" X 20" 20" X 16" N/A AOPS8397 AOPS8414 AOPS8394 BECKETT AFG 380754 20" X 20" 20" X 16" ACCESSORY ITEMS 380705 AOPS8416 AOPS8414 AOPS8395 RIELLO BF5 380756 20" X 20" 20" X 16" N/A AOPS8433 AOPS8414 AOPS8432 CARLIN EZ-1HP 380836 1 OUTPUT BTUH BASED ON ANNUAL FUEL UTILIZATION EFFICIENCY RATED BY MANUFACTURER. 2 SEASONAL EFFICIENCY (ALSO CALLED AFUE - ANNUAL FUEL UTILIZATION EFFICIENCY) RATINGS ARE BASED ON TESTS FOLLOWING U.S. DEPARTMENT OF ENERGY TEST PROCEDURES. 3 TO PERMIT LARGEST RECOMMENDED AIR CONDITIONING (AT .5 STATIC PRESSURE), SELECTION OF THE HIGHEST MOTOR SPEED IS REQUIRED. . PS020026 15 ECN 5447-MA 200129 OIL FIRED UPFLOW FURNACE SPECIFICATIONS MODEL NO. HEATING CAPACITY HEAT INPUT RATE (BTUH) OUTPUT BTUH1 SEASONAL EFFICIENCY2 LARGEST REC A/C3 NOMINAL TEMP RISE HEAT EXCHANGER AREA CASING HEIGHT (IN.): CASING WIDTH (IN.): CASING DEPTH (IN.): NOMINAL FLUE OUTLET DIA. APPROX SHIPPING WEIGHT LBS APPROVAL STANDARDS QTY AND SIZE OF PERMANENT FILTERS ELECTRICAL REQUIREMENTS VAC/HZ/PH MAX FUSE SIZE (AMPS) TOTAL CURRENT (AMPS) OL20*A151T60 B 185,000 153,000 85.0% 5 Tons 70 7525 SQ IN 50-1/2" 27" 58-1/2" 7" 600 UL727 (2) 14" X 25" 120/60/1 20 18.9 OL20*A151T60 R 185,000 153,000 85.0% 5 Tons 70 7525 SQ IN 50-1/2" 27" 58-1/2" 7" 600 UL727 (2) 14" X 25" 120/60/1 20 18.9 HEIGHT FROM FLOOR TO CENTER OF FLUE 44-1/4" 44-1/4" SUPPLY AIR OUTLET SIZE (W-IN. X D-IN.) RETURN AIR INLET OPENING SIZE (W-IN. X D-IN.) COMBUSTION AIR INTAKE HOOD KIT OIL BURNER 22" X 22" 22" X 22" 22" X 18" 22" X 18" ACCESSORY ITEMS PVB-2 N/A BECKETT AFG 380739 RIELLO F5 ROB-20 1 OUTPUT BTUH BASED ON ANNUAL FUEL UTILIZATION EFFICIENCY RATED BY MANUFACTURER. 2 SEASONAL EFFICIENCY (ALSO CALLED AFUE - ANNUAL FUEL UTILIZATION EFFICIENCY) RATINGS ARE BASED ON TESTS FOLLOWING U.S. DEPARTMENT OF ENERGY TEST PROCEDURES. 3 TO PERMIT LARGEST RECOMMENDED AIR CONDITIONING (AT .5 STATIC PRESSURE), SELECTION OF THE HIGHEST MOTOR SPEED IS REQUIRED. PS020027 16 ECN 5647-MA 200813 OIL FIRED FURNACE SPECIFICATIONS MODEL SERIES BTU OUTPUT BECKETT AFG RIELLO CARLIN HEIGHT OF CASING WIDTH OF CASING DEPTH OF CASING WARM AIR OUTLET (WxD in inches) RETURN AIR INLET (WxD in inches) DIAMETER OF FLUE FLOOR TO CENTER OF FLUE (IN.) STANDARD BLOWER MOTOR OPTIONAL ECM BLOWER MTR CFM @ 0.2 &0.5 W.C. BELT DRIVE STANDARD D.D. HI SPEED PSC MH SPEED MED. SPEED ML SPEED LOW SPEED A/C CAPACITY BELT3 D.D. PSC D.D. PSC UPGRADE BECKETT NOZZLE SIZE GPH SPRAY ANGLE/PATTERN PUMP PRESSURE RIELLO NOZZLE SIZE SPRAY ANGLE/PATTERN PUMP PRESSURE SHIPPING WEIGHT (LBS.) SEASONAL AFUE BECKETT4 SEASONAL AFUE RIELLO OT11-1051 HORIZONTAL OT16-1251 101,000 101,000 N/A 123,000/134,550 123,000 N/A 24" 74" 24 1/2" 20"x20" 20"x20" 26" 74" 26" 22"x20" 22"x20" 6" 7" 1/2 HP 4-speed N/A 3/4 HP 4-speed N/A 0.2" 0.5" 0.2" 0.5" 1596 1329 1069 863 1408 1162 940 742 2237 2062 2020 1897 1877 1789 NOT RECOMMENDED 3 1/2 Ton 4 Ton 0.90 80° A 100 PSI 0.75 80° A 145 445 83% 83% 5 Ton 1.10 1.25 80° A 120 PSI 0.90 80° A 145 500 83% 83% 1)Alternate plenum flanges supplied with furnace, must be installed for 20" width.. All models on Chart are UL Listed. All specifications subject to change without notice. PS020019 Rev 050222 17 SINGLE STAGE CONDENSING GAS MULTI-POSITION FURNACE SPECIFICATIONS MODEL NO. FUEL CLQS1-050T36N GAS NAT/LP 4 CLQS1-075T42N CLQS1-100T48N CLQS1-125T60N GAS NAT/LP 4 GAS NAT/LP 4 GAS NAT/LP 4 INPUT BTUH 50,000 75,000 OUTPUT BTUH1 SEASONAL EFFICIENCY2 LARGEST REC A/C3 NOMINAL TEMP RISE APPROX EFFECTIVE HEATING SURFACE APPROX SHIPPING WEIGHT APPROVAL AGENCY DIA OF FLUE (PVC) DIA OF COMBUSTION AIRINTAKE (PVC) SUPPLY AIR OUTLET SIZE (W-IN x D-IN) RETURN AIR DUCTWORK CONNECTION ON FRIELTTUERRNRAAICRKIN(DL-EINT xOPHE-INNI)NG IN SIDE CASING (TO BE CUTOUT BY DEALER) (D-IN x H-IN) QTY AND SIZE OF PERMANENT FILTERS ELECTRICAL RATING MAX FUSE SIZE COMBUSTIBLE FLOOR BASE CE COIL CABINET FILTER RACK CONCENTRIC VENT KIT SIDEWALL VENT CAP NEUTRALIZER KIT MINI CONDENSATE PUMP KIT SUPPLY PLENUM RETURN AIR DROP FURNACE PARTS KIT 48,000 95.0% 3 T 60° 4225 SQ IN. 155 LBS ETL 2" 2" 16-1/2" x 20" (20"x20")5 24-1/2" x 15" 23-1/8" x 14-1/8" ONE 1" x 25" x 16" 115V 60HZ 1PH 15 AMP 50CLQ-BASE CE215T AOPS7547 AOPS7488 370191 320095 AOPS7614 PK164X202 RD2510X2516 AOPS7768 73,000 95.0% 3.5 T 60° 4490 SQ IN. 166 LBS ETL 2" 2" 20" x 20" 24-1/2" x 15" 23-1/8" x 14-1/8" ONE 1" x 25" x 16" 115V 60HZ 1PH 15 AMP ACCESSORY ITEMS 125CLQ-BASE CE216T AOPS7547 AOPS7488 370191 320095 AOPS7614 PK202X202 RD2510X2516 AOPS7768 100,000 96,000 95.0% 4 T 60° 5550 SQ IN. 183 LBS ETL 3" 3" 20" x 20" 24-1/2" x 15" 23-1/8" x 14-1/8" ONE 1" x 25" x 16" 115V 60HZ 1PH 15 AMP 125CLQ-BASE CE216T AOPS7547 AOPS7489 370191 320095 AOPS7614 PK202X202 RD2510X2516 AOPS7768 125,000 120,000 95.0% 5 T 60° 5815 SQ IN. 196 LBS ETL 3" 3" 20" x 20" 23-3/4" x 19" 23-1/8" x 14-1/8" ONE 1" x 25" x 20" 115V 60HZ 1PH 15 AMP 125CLQ-BASE CE217T AOPS7375 AOPS7489 370191 320095 AOPS7614 PK202X202 RD2512X2520 AOPS7768 1 OUTPUT BTUH BASED ON AHRI LISTING. 2 SEASONAL EFFICIENCY (ALSO CALLED AFUE - ANNUAL FUEL UTILIZATION EFFICIENCY) RATINGS ARE BASED ON TESTS FOLLOWING U.S. DEPARTMENT OF ENERGY TEST PROCEDURES. 3 TO PERMIT LARGEST RECOMMENDED AIR CONDITIONING (AT .5 STATIC PRESSURE), SELECTION OF THE HIGHEST MOTOR SPEED IS REQUIRED. 4 LP CONVERSION KIT SHIPPED WITH FURNACE. 5 PLENUM ADAPTERS INCLUDED WITH UNIT MUST BE INSTALLED FOR 20"x20" PLENUM. ALL SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. PS030010 ECN 5555-MA 181024 18 OIL-FIRED MOBILE HOME FURNACE SPECIFICATIONS MODEL NO. HEAT INPUT RATE (BTUH) OUTPUT (BTUH)1 SEASONAL EFFICIENCY2 FUEL NOMINAL TEMP. RISE CASING HEIGHT (IN.) CASING WIDTH (IN.) CASING DEPTH (IN.) FLUE DIAMETER (IN.) NOMINAL FLUE OUTLET DIAMETER (IN.) APPROX. SHIPPING WEIGHT (LBS.) APPROVAL AGENCY SIZE OF PERM. FILTER ELECTRICAL REQUIREMENTS MAX FUSE SIZE TOTAL RATED CURRENT AMPS. SUPPLY AIR OUTLET SIZE (W-IN X D-IN) RETURN AIR INLET OPENING SIZE NOMINAL HEAT ANTICIPATOR SETTING MOBILE HOME BASE COTTAGE BASE COIL CABINET FOR 2-3 TON ROOF JACK 12" OR LESS ROOF JACK 13" TO 24" ROOF JACK 25" TO 36" VENT PIPE SLOPE ADAPTOR 2-1/2-12 SLOPE ADAPTOR 3-1/2-12 COMBUSTION AIR INTAKE HOOD TRANSITION BOOT w\ SCREEN BLOCKED VENT KIT3 ROOF JACK COMBUSTION AIR KIT OFFSET VENT KIT OME-72D36 / OME-72T36 LOW FIRE HIGH FIRE 70,000 85,000 60,000 72,000 86% 86% #2 FUEL OIL 66º 57" 18" 24-3/4" 4" 4" 240 LBS. ETL 18" X 24" 115 VAC / 60 HZ / 1 PHASE 15 AMPS 11 12" X 12" 14" X 22" (LOUVERED) 0.2mA ACCESSORY ITEMS 70-BASE 01COT-BASE CE111S TRJ-1 TRJ-2 TRJ-3 VP-1 TSA-25 TSA-30 AOPS7402 AOPS8419 AOPS2686 AOPS7512 AOPS7518 1 OUTPUT BTUH BASED ON ANNUAL FUEL UTILIZATION EFFICIENCY RATED BY MANUFACTURER. 2 SEASONAL EFFICIENCY (ALSO CALLED AFUE-ANNUAL FUEL UTILIZATION EFFICIENCY) RATINGS ARE BASED ON TESTS FOLLOWING U.S. DEPARTMENT OF ENERGY TEST PROCEDURES. 3 NOT TO BE USED IN MOBILE HOME APPLICATIONS WITH A ROOF-JACK. PS040004 ECN 5583-MA 190617 19 GAS-FIRED MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS MODEL NO. HEAT INPUT RATE (BTUH) OUTPUT (BTUH)1 SEASONAL EFFICIENCY2 LARGEST REC A/C3 FUEL BURNER ORIFICE GAS SUPPLY PRESSURE (IN W.G.) MINIMUM REQUIRED MAXIMUM ALLOWED GAS MANIFOLD PRESSURE (IN W.G.) NOMINAL TEMP. RISE VENT PIPE SIZE (IN.) CASING HEIGHT (IN.) CASING WIDTH (IN.) CASING DEPTH (IN.) APPROX. SHIPPING WEIGHT (LBS.) APPROVAL AGENCY SIZE OF PERM. FILTER ELECTRICAL REQUIREMENTS MAX FUSE SIZE TOTAL RATED CURRENT AMPS. SUPPLY AIR OUTLET SIZE (W-IN X D-IN) RETURN AIR INLET OPENING SIZE NOMINAL HEAT ANTICIPATOR SETTING MOBILE HOME BASE COTTAGE BASE COIL CABINET 3 TON A/C UPGRADE KIT (GMD2-80 ONLY) ROOF JACK 12" OR LESS ROOF JACK 13" TO 24" ROOF JACK 25" TO 36" SLOPE ADAPTOR 2-1/2-12 SLOPE ADAPTOR 3-1/2-12 4" STAINLESS STEEL VENT PIPE (34" LG) COMBUSTION AIR INTAKE HOOD FLEXIBLE STAINLESS STEEL OFFSET VENT KIT TRANSITION BOOT W/ SCREEN GMD2-60 60,000 50,000 81.6 2.5 TONS NAT LP #38 #52 GMD2-80 80,000 65,000 81 2.5 TONS (AS SHIPPED) 3 TONS WITH UPGRADE KIT NAT LP 2.45mm #53 5.5 11 5.5 14.0 14.0 14.0 3.5±0.3 10±0.3 3.5±0.3 60º 70º 4" 57" 18" 25 ¾" 165 LBS. ETL 18" X 24" 115 VAC/ 60 HZ/ 1 PHASE 15 AMPS 7.15 12" X 12" 14" X 22" 0.8 mA ACCESSORY ITEMS 70-BASE 01COT-BASE CE111S AOPS2677 TRJ-1 TRJ-2 TRJ-3 TSA-25 TSA-30 VP-1 AOPS7402 11 14.0 10±0.3 AOPS7518 AOPS8419 1 OUTPUT BTUH BASED ON ANNUAL FUEL UTILIZATION EFFICIENCY RATED BY MANUFACTURER. 2 SEASONAL EFFICIENCY (ALSO CALLED AFUE-ANNUAL FUEL UTILIZATION EFFICIENCY) RATINGS ARE BASED ON TESTS FOLLOWING U.S. DEPARTMENT OF ENERGY TEST PROCEDURES. 3 TO PERMIT LARGEST RECOMMENDED AIR CONDITIONING (AT .5 STATIC PRESSURE), SELECTION OF THE HIGHEST MOTOR SPEED IS REQUIRED. PS040008 ECN 5580-MA 20 GAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS MODEL NO. HEAT INPUT RATE (BTUH) OUTPUT (BTUH)1 SEASONAL EFFICIENCY2 LARGEST REC A/C3 FUEL BURNER ORIFICE GAS SUPPLY PRESSURE (IN W.G.) MINIMUM REQUIRED MAXIMUM ALLOWED GAS MANIFOLD PRESSURE (IN W.G.) NOMINAL TEMP. RISE VENT PIPE SIZE (IN.) CASING HEIGHT (IN.) CASING WIDTH (IN.) CASING DEPTH (IN.) APPROX. SHIPPING WEIGHT (LBS.) APPROVAL AGENCY SIZE OF PERM. FILTER ELECTRICAL REQUIREMENTS MAX FUSE SIZE TOTAL RATED CURRENT AMPS. SUPPLY AIR OUTLET SIZE (W-IN X D-IN) NOMINAL HEAT ANTICIPATOR SETTING MOBILE HOME BASE COTTAGE BASE COIL CABINET FOR 2-3 TON CONCENTRIC VENT KIT (FOR 4" FLUE RJ) CONCENTRIC VENT KIT (FOR 5" FLUE RJ) DUAL PIPE FLASHING KIT BAYVENT SIDE WALL VENT KIT SLOPE ADAPTER 2-1/2 / 12 SLOPE ADAPTER 3-1/2 / 12 MINI CONDENSATE PUMP KIT NEUTRALIZING KIT CMA4-50D36 50,000 48,000 95% 3 TONS NAT LP #42 #54 CMA4-75D36 75,000 72,000 95% 3 TONS NAT LP #42 #54 4.5 11 4.5 11 14 14 14 14 3.5±0.3 10±0.3 3.5±0.3 10±0.3 55º 65º 2" PVC 2" PVC 57" 57" 18" 18" 25 3/4" 25 3/4" 175 LBS. 185 LBS. ETL ETL 18" X 24" 18" X 24" 115 VAC/ 60 HZ/ 1 PHASE 115 VAC/ 60 HZ/ 1 PHASE 15 AMPS 15 AMPS 7.15 7.15 12" X 12" 12" X 12" 0.8mA 0.8mA ACCESSORY ITEMS 70BASE 70BASE 01COT-BASE 01COT-BASE CE111S CE111S AOPS7483 AOPS7483 AOPS7544 AOPS7544 AOPS7484 AOPS7484 370191 370191 TSA-25 TSA-25 TSA-30 TSA-30 AOPS7614 320095 AOPS7614 320095 1 OUTPUT BTUH BASED ON ANNUAL FUEL UTILIZATION EFFICIENCY RATED BY MANUFACTURER. 2 SEASONAL EFFICIENCY (ALSO CALLED AFUE-ANNUAL FUEL UTILIZATION EFFICIENCY) RATINGS ARE BASED ON TEST FOLLOWING U.S. DEPARTMENT OF ENERGY TEST PROCEDURES. 3 TO PERMIT LARGEST RECOMMENDED AIR CONDITIONING (AT .5 STATIC PRESSURE), SELECTION OF THE HIGHEST MOTOR SPEED IS REQUIRED. PS040009 ECN 5580-MA 21 GAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS MODEL NO. HEAT INPUT RATE (BTUH) OUTPUT (BTUH)1 SEASONAL EFFICIENCY2 LARGEST REC A/C3 FUEL BURNER ORIFICE GAS SUPPLY PRESSURE (IN W.G.) MINIMUM REQUIRED MAXIMUM ALLOWED GAS MANIFOLD PRESSURE (IN W.G.) NOMINAL TEMP. RISE VENT PIPE SIZE (IN.) CASING HEIGHT (IN.) CASING WIDTH (IN.) CASING DEPTH (IN.) APPROX. SHIPPING WEIGHT (LBS.) APPROVAL AGENCY SIZE OF PERM. FILTER ELECTRICAL REQUIREMENTS MAX FUSE SIZE TOTAL RATED CURRENT AMPS. SUPPLY AIR OUTLET SIZE (W-IN X D-IN) NOMINAL HEAT ANTICIPATOR SETTING CONCENTRIC VENT KIT (FOR 4" FLUE RJ) CONCENTRIC VENT KIT (FOR 5" FLUE RJ) DUAL PIPE FLASHING KIT BAYVENT SIDE WALL VENT KIT SLOPE ADAPTER 2-1/2 / 12 SLOPE ADAPTER 3-1/2 / 12 MINI CONDENSATE PUMP KIT NEUTRALIZING KIT CMC2-50D36 (DV3) 50,000 48,000 95% 3 TONS NAT LP #42 #54 CMC2-75D36 (DV3) 75,000 72,000 95% 3 TONS NAT LP #42 #54 4.5 11 4.5 11 14 14 14 14 3.5±0.3 10±0.3 3.5±0.3 10±0.3 55º 65º 2" PVC 2" PVC 76 1/8" 76 1/8" 18 3/4" 18 3/4" 25 3/4" 25 3/4" 195 LBS. 205 LBS. ETL ETL 18" X 24" 18" X 24" 115 VAC/ 60 HZ/ 1 PHASE 115 VAC/ 60 HZ/ 1 PHASE 15 AMPS 15 AMPS 7.15 7.15 12" X 12" 12" X 12" 0.8mA 0.8mA ACCESSORY ITEMS AOPS7483 AOPS7483 AOPS7544 AOPS7544 AOPS7484 AOPS7484 370191 370191 TSA-25 TSA-25 TSA-30 TSA-30 AOPS7614 AOPS7614 320095 320095 1 OUTPUT BTUH BASED ON ANNUAL FUEL UTILIZATION EFFICIENCY RATED BY MANUFACTURER. 2 SEASONAL EFFICIENCY (ALSO CALLED AFUE-ANNUAL FUEL UTILIZATION EFFICIENCY) RATINGS ARE BASED ON TEST FOLLOWING U.S. DEPARTMENT OF ENERGY TEST PROCEDURES. 3 TO PERMIT LARGEST RECOMMENDED AIR CONDITIONING (AT .5 STATIC PRESSURE), SELECTION OF THE HIGHEST MOTOR SPEED IS REQUIRED. PS040010 ECN 5580-MA 22 Air Handlers with Optional Hydronic Heating Coils The Thermo Pride air handlers are designed to be used as a stand-alone cooling, stand-alone heating or combination heating and cooling air handler. The air handlers can be installed in a upflow or horizontal applications. The cooling coil comes factory installed. In heating mode, our air handler provides up to 70° temperature rise (at 180°F entering water temperature), which provides warmer air than many air handlers on the market. All units operate on 115V and coils use 410A refrigerant. Our air handler requires little maintenance and provides efficiency, longevity, and worry-free comfort. It also comes with our standard 10-year coil and 5-year parts warrany. 23 MODEL SERIES DESCRIPTION BURNER BTU OUTPUT HEIGHT OF CASING WIDTH OF CASING DEPTH OF CASING WARM AIR OUTLET (WxD) RETURN AIR INLET (WxD) DIAMETER OF FLUE FLOOR TO CENTER OF FLUE BLOWER MOTOR CFM @ 0.2 & 0.5 W.C. STANDARD LOW SPEED ML SPEED MED. SPEED MH SPEED HIGH SPEED A/C CAPACITY BECKETT NOZZLE SIZE GPH CARLIN NOZZLE SIZE GPH SPRAY ANGLE/PATTERN PUMP PRESSURE VHF-ABP HIGHBOY Beckett 60,000 / 72,000 90,000 VHF-ACP HIGHBOY Carlin 60,000 / 72,000 90,000 SPIRIT OIL FIRED FURNACE SPECIFICATIONS VHF-ABT HIGHBOY Beckett 60,000 / 72,000 90,000 VHF-ACT HIGHBOY Carlin 60,000 / 72,000 90,000 VH8FA119P60B HIGHBOY Beckett 101,000 / 119,000 132,000 VH8FA119T60B HIGHBOY Beckett 101,000 / 119,000 132,000 VLF-DBP VLR-DBP LOWBOY Beckett 70,000 / 88,000 98,000 / 114,000 VLF-DCP VLR-DCP LOWBOY Carlin 70,000 / 88,000 98,000 / 114,000 VL8FA119P60B VL8RA119P60B LOWBOY Beckett 101,000 / 119,000 132,000 VC-CBP HORIZONTAL/ COUNTERFLOW Beckett 69,000 / 88,000 97,000 45" 21" 30" 19" x 19" 24" x 14 1/4" 5" 40 11/16" 45" 21" 30" 19" x 19" 24" x 14 1/4" 5" 40 11/16" 45" 21" 30" 19" x 19" 24" x 14 1/4" 5" 40 11/16" 45" 21" 30" 19" x 19" 24" x 14 1/4" 5" 40 11/16" 50 1/8" 24 1/2" 36 1/2" 20" x 20" 23-3/4" x 19" 7" 42 3/4" 50 1/8" 24 1/2" 36 1/2" 20" x 20" 23-3/4" x 19" 7" 42 3/4" 41 1/2" 22 1/4" 47" 20" x 20" 20" x 12 1/2" 6" 30 3/8" 41 1/2" 22 1/4" 47" 20" x 20" 20" x 12 1/2" 6" 30 3/8" 38 1/2" 24 1/2" 55 1/2" 20" x 20" 20" x 16" 7" 29 1/2" 61 1/4" 22 1/4" 22 1/4" 16" x 16" 16" x 16" 6 29 7/8" 1/2HP-4SPD-PSC 1/2HP-4SPD-PSC 1/2HP-5SPD-ECM 1/2HP-5SPD-ECM 3/4HP-4SPD-PSC 0.2 0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.2 0.5 915 1152 1432 1762 822 1085 1334 1569 915 1152 1432 1762 822 1085 1334 1569 1012 1172 1303 1498 1650 821 1037 1205 1399 1561 1012 1172 1303 1498 1650 821 1037 1205 1399 1561 1300 1526 1874 2228 1237 1458 1746 2069 1 HP-5SPD-ECM 0.2 0.5 1429 1593 1693 1766 2185 1222 1422 1520 1596 2045 3/4HP-4SPD-PSC 0.2 0.5 CFM for Front Flue, see specs for Rear Flue 1106 1023 1339 1216 3/4HP-4SPD-PSC 0.2 0.5 CFM for Front Flue, see specs for Rear Flue 1106 1023 1339 1216 1 HP-4SPD-PSC, Front Flue 3/4HP-4SPD-PSC, Rear Flue 0.2 0.5 CFM for Front Flue, see specs for Rear Flue 1344 1234 1611 1496 1572 1822 1376 1564 1572 1822 1376 1564 1868 2235 1710 2012 1/2HP-4SPD-PSC 0.2 0.5 1139 1274 1397 1550 1017 1111 1209 1347 4 Ton 4 Ton 4 Ton 4 Ton 5 Ton 5 Ton 4 Ton 4 Ton 5 Ton 3.5 Ton .50 .60 .75 N/A 80° A 120 PSI N/A .50 .60 .75 60° A 120 PSI .50 .60 .75 N/A 80° A 120 PSI N/A .50 .60 .75 60° A 120 PSI .85 1.00 1.10 N/A 80° A 120 PSI .85 1.00 1.10 N/A 80° A 120 PSI .60 .75 .85 1.00 N/A 80° A 130 PSI N/A .60 .75 .85 1.00 60° A 140 PSI .85 1.00 1.10 N/A 80° A 120 PSI .60 .75 .85 N/A 80° A 130 PSI SHIPPING WEIGHT SEASONAL AFUE BECKETT SEASONAL AFUE CARLIN 270 LBS. 85% N/A 270 LBS. N/A 86% 270 LBS. 85% N/A 270 LBS. N/A 86% 335 LBS. 85% N/A For complete specifications see specifications on line at www.thermopride.com/products/spiritfurnace/manuals-specifications-literature/specifications/ All specifications subject to change without notice 335 LBS. 85% N/A 305 LBS 85% N/A 305 LBS N/A 86% 345 LBS 85% N/A 300 LBS 85% N/A Rev 120420 Scan this code with your smart phone to visit our website. www.thermopride.com Thermo Products, LLC Healing & Air Conditioning Thermo Products, LLC P.O. Box237 Denton, NC 27239 800-348-5130 or 800-476-4328 www.thermopride.com www.spiritfurnace.com MS601002 Rev.050222Adobe Acrobat Pro DC (32-bit) 21.1.20149