MEASUREMENT REPORT
FCC PART 15.407 DFS

Company Name: Samsung Electronics Co., Ltd.
129, Samsung-ro,
Yeongtong-gu, Suwon-si Gyeonggi-do, 16677, Korea

Date of Testing: 3/10-4/28/2016
Test Site/Location: PCTEST Lab. Columbia, MD, USA
Test Report Serial No.: 0Y1603110509.A3L

FCC ID: COMPANY:

A3LSMT585 Samsung Electronics Co., Ltd.

Model(s): EUT Type: Type of Device: Frequency Range:
Output Power:
FCC Classification: FCC Rule Part(s): Test Procedure(s):

SM-T585, SM-T587 Portable Tablet Client Only Device, No Radar Detection Capability 5260 ­ 5320 MHz (UNII-2A Band) 5500 ­ 5720 MHz (UNII-2C Band) 34.995 mW (15.44 dBm) Conducted (802.11a UNII Band 2A) 35.075 mW (15.45 dBm) Conducted (802.11n UNII Band 2C) Unlicensed National Information Infrastructure (UNII) Part 15.407(UNII) KDB 905462 D02 v02

This equipment has been shown to be capable of compliance with the applicable technical standards as indicated in the measurement report and was tested in accordance with the measurement procedures specified in KDB 905462 D02 v02 Compliance Measurement Procedures for Unlicensed-National Information Infrastructure Devices Operating in the 5.25 ­ 5.35 GHz and 5.47 ­ 5.725 GHz Bands Incorporating Dynamic Frequency Selection. Test results reported herein relate only to the item(s) tested.
I attest to the accuracy of data. All measurements reported herein were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them.

FCC ID: A3LSMT585

Test Report S/N:

Test Dates:

0Y1603110509.A3L

3/10-4/28/2016

© 2016 PCTEST Engineering Laboratory, Inc.

FCC Pt. 15.407 DFS TEST REPORT (CERTIFICATION)
EUT Type: Portable Tablet

Reviewed by: Quality Manager
Page 1 of 16
V 3.3 12/01/2015

TABLE OF CONTENTS
FCC PART 15.407 MEASUREMENT REPORT .................................................................................................. 3 1.0 INTRODUCTION......................................................................................................................................4
1.1 Scope ............................................................................................................................................................. 4 1.2 Evaluation Procedure ..................................................................................................................................... 4 1.3 Summary of Test Results ............................................................................................................................... 4
2.0 PRODUCT INFORMATION .....................................................................................................................5
2.1 Equipment Description ................................................................................................................................... 5 2.2 EUT Capabilities............................................................................................................................................. 5 2.3 Modifications .................................................................................................................................................. 5
3.0 DESCRIPTION OF DYNAMIC FREQUENCY SELECTION TEST .........................................................6
3.1 Applicability .................................................................................................................................................... 6 3.2 Requirements ................................................................................................................................................. 6 3.3 DFS Detection Threshold Values ................................................................................................................... 8 3.4 Parameters of DFS Test Signals .................................................................................................................... 8 3.5 Procedure....................................................................................................................................................... 9
4.0 TEST EQUIPMENT................................................................................................................................10
4.1 Additional Equipment ................................................................................................................................... 10
5.0 TEST RESULTS ....................................................................................................................................11 6.0 CONCLUSION .......................................................................................................................................16

FCC ID: A3LSMT585

Test Report S/N:

Test Dates:

0Y1603110509.A3L

3/10-4/28/2016

© 2016 PCTEST Engineering Laboratory, Inc.

FCC Pt. 15.407 DFS TEST REPORT (CERTIFICATION)
EUT Type: Portable Tablet

Reviewed by: Quality Manager
Page 2 of 16
V 3.3 12/01/2015

DFS MEASUREMENT REPORT
FCC Part 15.407

§ 2.1033 General Information

APPLICANT: APPLICANT ADDRESS:

Samsung Electronics Co., Ltd. 129, Samsung-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16677, Korea

TEST SITE: TEST SITE ADDRESS:

PCTEST ENGINEERING LABORATORY, INC. 7185 Oakland Mills Road, Columbia, MD 21046 USA

FCC RULE PART(S): BASE MODEL:

Part 15.407(h) SM-T585

FCC ID: Test Device Serial No.:

A3LSMT585 19695

Production Pre-Production

DEVICE CLASSIFICATION: Client Only, No Radar Detection

DATE(S) OF TEST: TEST REPORT S/N:

3/10-4/28/2016 0Y1603110509.A3L

Engineering

Test Facility / Accreditations
Measurements were performed at PCTEST Engineering Lab located in Columbia, MD 21045, U.S.A.
 PCTEST facility is an FCC registered (PCTEST Reg. No. 159966) test facility with the site description report on file and has met all the requirements specified in Section 2.948 of the FCC Rules and Industry Canada (2451B-1).
 PCTEST Lab is accredited to ISO 17025 by U.S. National Institute of Standards and Technology (NIST) under the National Voluntary Laboratory Accreditation Program (NVLAP Lab code: 100431-0) in EMC, FCC and Telecommunications.
 PCTEST Lab is accredited to ISO 17025-2005 by the American Association for Laboratory Accreditation (A2LA) in Specific Absorption Rate (SAR) testing, Hearing Aid Compatibility (HAC) testing, CTIA Test Plans, and wireless testing for FCC and Industry Canada Rules.
 PCTEST Lab is a recognized U.S. Conformity Assessment Body (CAB) in EMC and R&TTE (n.b. 0982) under the U.S.-EU Mutual Recognition Agreement (MRA).
 PCTEST TCB is a Telecommunication Certification Body (TCB) accredited to ISO/IEC Guide 65 by the American National Standards Institute (ANSI) in all scopes of FCC Rules and Industry Canada Standards (RSS).
 PCTEST facility is an IC registered (2451B-1) test laboratory with the site description on file at Industry Canada.
 PCTEST is a CTIA Authorized Test Laboratory (CATL) for AMPS, CDMA, and EvDO wireless devices and for Over-the-Air (OTA) Antenna Performance testing for AMPS, CDMA, GSM, GPRS, EGPRS, UMTS (W-CDMA), CDMA 1xEVDO, and CDMA 1xRTT.

FCC ID: A3LSMT585

Test Report S/N:

Test Dates:

0Y1603110509.A3L

3/10-4/28/2016

© 2016 PCTEST Engineering Laboratory, Inc.

FCC Pt. 15.407 DFS TEST REPORT (CERTIFICATION)
EUT Type: Portable Tablet

Reviewed by: Quality Manager
Page 3 of 16
V 3.3 12/01/2015

1.0 I N T R O D U C T I O N
1.1 Scope
This report has been prepared to demonstrate compliance with the requirements for Dynamic Frequency Selection (DFS) as stated in KDB 905462 D02 V02. Testing was performed on the Samsung Portable Tablet FCC ID: A3LSMT585. As of July 20, 2007 all devices operating in the 5250 ­ 5350 MHz and/or the 5470 ­ 5725 MHz bands must comply with the DFS requirements. As the EUT does not have radar detection capability it was evaluated as a Client Only Device. All test results reported herein are applicable to the sample selected for testing. The unit used for testing was supplied by Samsung Electronics Co., Ltd..
1.2 Evaluation Procedure
Conducted test methodology was used for the DFS evaluation procedure of the Samsung Portable Tablet FCC ID: A3LSMT585. No deviations to the test procedure and test methods occurred during the evaluation of the EUT.
1.3 Summary of Test Results
The Samsung Portable Tablet FCC ID: A3LSMT585 was found to be compliant with the requirements for DFS as required for a Client Device per Part 15.407(h) and KDB 905462 D02 V02. The following table lists the measured parameters. The actual data and plots can be found in Section 5 and 6 of this report.

5260 ­ 5320 MHz UNII ­ 2A Band

Parameter

Measured

Limit

Result

Channel Move Time

9.21 s

10 seconds

Channel Closing Transmission Time Client beacon test

< 200ms + 0.63 ms (aggregate)
Monitored for 10 minutes with no client transmission

200ms + aggregate of 60ms over remaining 10 second period
No client transmission occurred

Channel Move Time

9.91 s

10 seconds

< 200ms

200ms + aggregate of

Channel Closing Transmission Time + 12.29 ms

60ms over remaining

(aggregate)

10 second period

Client beacon test

Monitored for 10 minutes with no client transmission

No client transmission occurred

Table 1-1. DFS Test Results Summary

Pass Pass Pass Pass Pass Pass

5470 ­ 5725 MHz
UNII ­ 2C Band

FCC ID: A3LSMT585

Test Report S/N:

Test Dates:

0Y1603110509.A3L

3/10-4/28/2016

© 2016 PCTEST Engineering Laboratory, Inc.

FCC Pt. 15.407 DFS TEST REPORT (CERTIFICATION)
EUT Type: Portable Tablet

Reviewed by: Quality Manager
Page 4 of 16
V 3.3 12/01/2015

2.0 P R O D U C T I N F O R M A T I O N
2.1 Equipment Description
The Equipment Under Test (EUT) is the Samsung Portable Tablet FCC ID: A3LSMT585. Mode of Operation:
Master Device Client Device (No radar detection) Client Device with Radar Detection

Parameters of EUT: Frequency

5260 ­ 5320 MHz 5500 ­ 5720 MHz

Output Power:

34.995 mW (15.44 dBm) Conducted (802.11a UNII Band 2A) 35.075 mW (15.45 dBm) Conducted (802.11n UNII Band 2C)

Modulation:

OFDM

Channel Bandwidth: 20, 40, 80 MHz

2.2 EUT Capabilities
This device contains the following capabilities:
850/1900 GSM/GPRS/EDGE, 850/1900 WCDMA/HSPA, Single-band LTE, 802.11b/g/n WLAN, 802.11a/n/ac UNII, Bluetooth (1x, EDR, LE), ANT+
2.3 Modifications
No modifications to the EUT were required in order to comply with the DFS specifications.

FCC ID: A3LSMT585

Test Report S/N:

Test Dates:

0Y1603110509.A3L

3/10-4/28/2016

© 2016 PCTEST Engineering Laboratory, Inc.

FCC Pt. 15.407 DFS TEST REPORT (CERTIFICATION)
EUT Type: Portable Tablet

Reviewed by: Quality Manager
Page 5 of 16
V 3.3 12/01/2015

3.0 D E S C R I P T I O N O F D Y N A M I C F R E Q U E N C Y S E L E C T I O N T E S T

3.1 Applicability
The following table from KDB 905462 D02 V02 lists the applicable requirements for the DFS testing. The device evaluated in this report is considered a client device without radar detection capability.

Requirement

Operational Mode

Non-Occupancy Period
DFS Detection Threshold Channel Availability Check Time Uniform Spreading

Master Yes Yes Yes Yes

Client Without Radar Detection
Not required

Client With Radar Detection
Yes

Not required

Yes

Not required

Not required

Not required

Not required

U-NII Detection Bandwidth

Yes

Not required

Yes

Table 3-1. DFS Applicability

Requirement

Operational Mode

DFS Detection Threshold

Master Yes

Client Without Radar
Detection
Not required

Channel Closing Transmission Time

Yes

Yes

Channel Move Time

Yes

Yes

U-NII Detection Bandwidth

Yes

Not required

Client Beacon Test

N/A

Yes

Table 3-2. DFS Applicability During Normal Operation

3.2 Requirements

Per KDB 905462 D02 V02 the following are the requirements for Client Devices:

Client With Radar Detection
Yes
Yes
Yes
Yes
Yes

a) A Client Device will not transmit before having received appropriate control signals from a Master Device.
b) A Client Device will stop all its transmissions whenever instructed by a Master Device to which it is associated and will meet the Channel Move Time and Channel Closing Transmission Time requirements.

FCC ID: A3LSMT585

Test Report S/N:

Test Dates:

0Y1603110509.A3L

3/10-4/28/2016

© 2016 PCTEST Engineering Laboratory, Inc.

FCC Pt. 15.407 DFS TEST REPORT (CERTIFICATION)
EUT Type: Portable Tablet

Reviewed by: Quality Manager
Page 6 of 16
V 3.3 12/01/2015

The Client Device will not resume any transmissions until it has again received control signals from a Master Device.
c) If a Client Device is performing In-Service Monitoring and detects a Radar Waveform above the DFS Detection Threshold, it will inform the Master Device. This is equivalent to the Master Device detecting the Radar Waveform and d) through f) of section 5.1.1 apply.
d) Irrespective of Client Device or Master Device detection the Channel Move Time and Channel Closing Transmission Time requirements remain the same.

Channel Move Time and Channel Closing Transmission Time requirements are listed in the following table.

Parameter

Value

Non-occupancy period

Minimum 30 minutes

Channel Availability Check Time

60 seconds

Channel Move Time Channel Closing Transmission Time

10 seconds
See Note 1. 200 milliseconds + an aggregate of 60 milliseconds over

U-NII Detection Bandwidth

remaining 10 second period. See Notes 1 and 2.
Minimum 80% of the UNII 99% transmission power bandwidth. See Note 3.

Note 1: The instant that the Channel Move Time and the Channel Closing Transmission Time begins is as follows: · For the Short Pulse Radar Test Signals this instant is the end of the Burst. · For the Frequency Hopping radar Test Signal, this instant is the end of the last radar Burst generated. · For the Long Pulse Radar Test Signal this instant is the end of the 12 second period defining the Radar Waveform. Note 2: The Channel Closing Transmission Time is comprised of 200 milliseconds starting at the beginning of the Channel Move Time plus any additional intermittent control signals required to facilitate a Channel move (an aggregate of 60 milliseconds) during the remainder of the 10 second period. The aggregate duration of control signals will not count quiet periods in between transmissions. Note 3: During the U-NII Detection Bandwidth detection test, radar type 1 is used and for each
frequency step the minimum percentage of detection is 90 percent. Measurements are performed with no data traffic.
Table 3-3: DFS Response Requirements

FCC ID: A3LSMT585

Test Report S/N:

Test Dates:

0Y1603110509.A3L

3/10-4/28/2016

© 2016 PCTEST Engineering Laboratory, Inc.

FCC Pt. 15.407 DFS TEST REPORT (CERTIFICATION)
EUT Type: Portable Tablet

Reviewed by: Quality Manager
Page 7 of 16
V 3.3 12/01/2015

3.3 DFS Detection Threshold Values
The DFS detection thresholds are defined for Master devices and Client Devices with In-service monitoring. These detection thresholds are listed in the following table.

Maximum Transmit Power

Value (See Notes 1 and 2)

 200 milliwatt

-64 dBm

< 200 milliwatt

-62 dBm

Note 1: This is the level at the input of the receiver assuming a 0 dBi receive antenna.

Note 2: Throughout these test procedures an additional 1 dB has been added to the amplitude of the test transmission waveforms to account for variations in measurement equipment. This will ensure that the test signal is at or above the detection threshold level to trigger a DFS response.
Table 3-4: Detection Thresholds for Master Devices and Client Devices with Radar Detection

3.4 Parameters of DFS Test Signals
As the EUT is a Client Device with no Radar Detection only one type radar pulse is required for the testing. Radar Pulse type 1 was used in the evaluation of the Client device for the purpose of measuring the Channel Move Time and the Channel Closing Transmission Time. Table 3-5 lists the parameters for the Short Pulse Radar Waveforms. A plot of the Radar Pulse Type 1 used for testing is included in Section 5.0 of this report.

Radar Type

Pulse Width (sec)

PRI (sec)

Number of
Pulses

Minimum Percentage of
Successful Detection

Minimum Number of
Trials

1

1

1428

18

60%

30

2

1-5

150-230

23-29

60%

30

3

6-10

200-500

16-18

60%

30

4

11-20

200-500

12-16

60%

30

Aggregate (Radar Types 1-4)

80%

120

Table 3-5: Parameters for Short Pulse Radar Waveforms

Radar Type
5

Pulse Width (sec)

Chirp Width (MHz)

PRI (sec)

Number of Pulses per Burst

Number of Bursts

Minimum Percentage of
Successful Detection

50 - 100

5 - 20

5 ­ 20

1 - 3

8 - 20

60%

Table 3-6. Parameters for Long Pulse Radar Waveforms

Minimum Number of
Trials
30

FCC ID: A3LSMT585

Test Report S/N:

Test Dates:

0Y1603110509.A3L

3/10-4/28/2016

© 2016 PCTEST Engineering Laboratory, Inc.

FCC Pt. 15.407 DFS TEST REPORT (CERTIFICATION)
EUT Type: Portable Tablet

Reviewed by: Quality Manager
Page 8 of 16
V 3.3 12/01/2015

Radar Type
6

Pulse Width (sec)

PRI (sec)

Pulses per Hop

Hopping Rate (kHz)

Hopping Sequence
Length (msec)

Minimum Percentage of
Successful Detection

1

333

9

0.333

300

70%

Table 3-7. Parameters for Frequency Hopping Radar Waveforms

Minimum Number
of Trials
30

3.5 Procedure

KDB 905462 D02 V02 describes a radiated test setup and a conducted test setup. The conducted test setup was used for this testing. Figure 3-1 shows the typical test setup. In Band 2A, one channel selected between 5260 and 5350 MHz is chosen for the testing. In Band 2C, one channel selected between 5500 and 5720 MHz was chosen for testing.

Figure 3-1. Conducted Test Setup for DFS
1. The "Aeroflex PXI DFS Radar Simulator and Analyzer Test Suite" is setup to provide a simulated radar pulse at the frequency that the Master and Client are operating. A Type 0 radar pulse was used.
2. The Client Device (EUT) is set up per the diagram in Figure 3-1 and communications between the Master device and the Client is established.
3. An MPEG or data file that is typical for the device is streamed from the Master to the Client to properly load the network.
4. The "Aeroflex PXI DFS Radar Simulator and Analyzer Test Suite" is set to record and display 12 seconds of time, starting from where the simulated radar is generated. This time domain plot captures any transmissions occurring up to and after 10sec. Aggregate time is computed to ensure compliance. (Note: the channel may be different since the Master and Client have changed channels due to the detection of the initial radar pulse.)
5. After the initial radar burst the channel is monitored for 10 minutes to ensure no transmissions or beacons occur. A second monitoring setup is used to verify that the Master and Client have both moved to different channels.

FCC ID: A3LSMT585

Test Report S/N:

Test Dates:

0Y1603110509.A3L

3/10-4/28/2016

© 2016 PCTEST Engineering Laboratory, Inc.

FCC Pt. 15.407 DFS TEST REPORT (CERTIFICATION)
EUT Type: Portable Tablet

Reviewed by: Quality Manager
Page 9 of 16
V 3.3 12/01/2015

4.0 T E S T E Q U I P M E N T

Test Equipment Calibration is traceable to the National Institute of Standards and Technology (NIST).

Manufacturer Model

Description

Cal Date Cal Interval Cal Due Serial Number

Aeroflex Agilent Seekonk

PXI 82531 PXI DFS Radar Simulator & Analyzer 5/20/2014 Biennial 5/20/2016

E4448A PSA (3Hz-50GHz) Spectrum Analyzer 3/1/2016 Annual 3/1/2017

NC-100

Torque Wrench 5/16", 8" lbs 3/2/2016 Biennial 3/2/2018

Table 4-1. Annual Test Equipment Calibration Schedule

1082329 US42510244
N/A

Note:

For equipment listed above that has a calibration date or calibration due date that falls within the test date range, care was taken to ensure that this equipment was used after the calibration date and before the calibration due date.

4.1 Additional Equipment

The following equipment was used in support of the DFS testing.

Device Manufacturer Model/Description Description

S/N:

Master

Cisco Systems

AIR-CAP2702E-A-K9 AIR-CT2504-K9 V03

Access Point Controller

Table 4-2. Support Equipment

FTX1834S05B PSZ18381P6K

FCC ID: A3LSMT585

Test Report S/N:

Test Dates:

0Y1603110509.A3L

3/10-4/28/2016

© 2016 PCTEST Engineering Laboratory, Inc.

FCC Pt. 15.407 DFS TEST REPORT (CERTIFICATION)
EUT Type: Portable Tablet

Reviewed by: Quality Manager
Page 10 of 16
V 3.3 12/01/2015

5.0 T E S T R E S U L T S
Channel Loading Notes: Per KDB 905462 D02 v02, timing plots are required with calculations demonstrating a minimum channel loading of approximately 17% or greater. For example, you can zero span the spectrum analyzer and approximate the transmission time.

Figure 5-1. Band 2A Pulse Width

Figure 5-2. Band 2A Period Channel Loading = Pulse Width / Period = 1.574 µs / 1.647 µs = 95.6 %

FCC ID: A3LSMT585

Test Report S/N:

Test Dates:

0Y1603110509.A3L

3/10-4/28/2016

© 2016 PCTEST Engineering Laboratory, Inc.

FCC Pt. 15.407 DFS TEST REPORT (CERTIFICATION)
EUT Type: Portable Tablet

Reviewed by: Quality Manager
Page 11 of 16
V 3.3 12/01/2015

Figure 5-3. Band 2C Pulse Width

Figure 5-4. Band 2C Period Channel Loading = Pulse Width / Period = 2.732 µs / 2.889 µs = 94.6 %

FCC ID: A3LSMT585

Test Report S/N:

Test Dates:

0Y1603110509.A3L

3/10-4/28/2016

© 2016 PCTEST Engineering Laboratory, Inc.

FCC Pt. 15.407 DFS TEST REPORT (CERTIFICATION)
EUT Type: Portable Tablet

Reviewed by: Quality Manager
Page 12 of 16
V 3.3 12/01/2015

Move Time and Aggregate Time Notes:
1. Trigger Threshold was configured to only capture client pulses. The pulses shown in the plots below have been determined to be from the Master AP.
2. Marker Info and Aggregate time results are shown on the right side of the plots below.

Figure 5-5. Band 2A Move Time and Aggregate Time

FCC ID: A3LSMT585

Test Report S/N:

Test Dates:

0Y1603110509.A3L

3/10-4/28/2016

© 2016 PCTEST Engineering Laboratory, Inc.

FCC Pt. 15.407 DFS TEST REPORT (CERTIFICATION)
EUT Type: Portable Tablet

Reviewed by: Quality Manager
Page 13 of 16
V 3.3 12/01/2015

Figure 5-6. Band 2C Move Time and Aggregate Time

FCC ID: A3LSMT585

Test Report S/N:

Test Dates:

0Y1603110509.A3L

3/10-4/28/2016

© 2016 PCTEST Engineering Laboratory, Inc.

FCC Pt. 15.407 DFS TEST REPORT (CERTIFICATION)
EUT Type: Portable Tablet

Reviewed by: Quality Manager
Page 14 of 16
V 3.3 12/01/2015

Figure 5-7. Band 2A Client Beacon Test ­ Monitoring live spectrum ­ Elapse time 10 minutes

Figure 5-8. Band 2C Client Beacon Test ­ Monitoring live spectrum ­ Elapse time 10 minutes

FCC ID: A3LSMT585

Test Report S/N:

Test Dates:

0Y1603110509.A3L

3/10-4/28/2016

© 2016 PCTEST Engineering Laboratory, Inc.

FCC Pt. 15.407 DFS TEST REPORT (CERTIFICATION)
EUT Type: Portable Tablet

Reviewed by: Quality Manager
Page 15 of 16
V 3.3 12/01/2015

6.0 C O N C L U S I O N
The data collected relate only to the item(s) tested and show that the Samsung Portable Tablet FCC ID: A3LSMT585 is in compliance with the DFS requirements for a Client Device without radar detection in accordance with Part 15.407 of the FCC Rules.

FCC ID: A3LSMT585

Test Report S/N:

Test Dates:

0Y1603110509.A3L

3/10-4/28/2016

© 2016 PCTEST Engineering Laboratory, Inc.

FCC Pt. 15.407 DFS TEST REPORT (CERTIFICATION)
EUT Type: Portable Tablet

Reviewed by: Quality Manager
Page 16 of 16
V 3.3 12/01/2015


GPL Ghostscript 9.18