Shenzhen Zhaoyang Tianxia Technology CO., Ltd. B08W-5MP-HX IP Camera 2AP56-B08W-5MP-HX 2AP56B08W5MPHX b08w 5mp hx
Test Report FCCID: 2AP56-B08W-5MP-HX Date of issue: Aug. 12, 2019 Report Number: MTi19070107-6E1 Sample Description: IP Camera Model(s): B08W-5MP-HX, B06W-3MP-HX, B06W-5MP-HX, B07W-1080P-HX, B08W-3MP-HX, B16VW-5MP-HX, SD5W-3MP-HX, SD5W-5MP-HX, SD7W-3MP-HX, SD7W-5MP-HX Applicant: Shenzhen Zhaoyang Tianxia Technology CO., Ltd. Address: Room217, Building C1, Bantian International Center, Bantian Street, Longgang District, Shenzhen, China Date of Test: July 10, 2019 to Aug. 12, 2019 Shenzhen Microtest Co., Ltd. http://www.mtitest.com This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen Microtest Co., Ltd. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 2 of 54 - Report No.: MTi19070107-6E1 Table of Contents 1 GENERAL INFORMATION..........................................................................................................................................5 1.1 DESCRIPTION OF EUT ...................................................................................................................................................5 1.2 OPERATION CHANNEL LIST..............................................................................................................................................6 1.3 TEST CHANNEL LIST .......................................................................................................................................................6 1.4 ANCILLARY EQUIPMENT LIST ...........................................................................................................................................6 1.5 DESCRIPTION OF SUPPORT UNITS ....................................................................................................................................6 2 SUMMARY OF TEST RESULTS ....................................................................................................................................8 3 TEST FACILITIES AND ACCREDITATIONS .....................................................................................................................9 3.1 TEST LABORATORY ........................................................................................................................................................9 3.2 ENVIRONMENTAL CONDITIONS ........................................................................................................................................9 3.3 MEASUREMENT UNCERTAINTY ........................................................................................................................................9 3.4 TEST SOFTWARE ...........................................................................................................................................................9 4 EQUIPMENT LIST .................................................................................................................................................... 10 5 TEST RESULT ........................................................................................................................................................... 11 5.1 ANTENNA REQUIREMENT .............................................................................................................................................11 5.1.1 Standard requirement.......................................................................................................................................11 5.1.2 EUT Antenna .....................................................................................................................................................11 5.2 PEAK OUTPUT POWER .................................................................................................................................................12 5.2.1 Limit ..................................................................................................................................................................12 5.2.2 Test setup ..........................................................................................................................................................12 5.2.3 Test procedure...................................................................................................................................................12 5.2.4 Test results.........................................................................................................................................................13 5.3 POWER SPECTRAL DENSITY ...........................................................................................................................................14 5.3.1 Limit ..................................................................................................................................................................14 5.3.2 Test Setup ..........................................................................................................................................................14 5.3.3 Test Procedure...................................................................................................................................................14 5.3.4 Test Results........................................................................................................................................................15 5.4 CONDUCTED EMISSION ................................................................................................................................................19 5.4.1 Limits.................................................................................................................................................................19 5.4.2 Test setup ..........................................................................................................................................................19 5.4.3 Test procedure...................................................................................................................................................20 5.4.4 Test results.........................................................................................................................................................21 5.5 RADIATED SPURIOUS ...................................................................................................................................................25 5.5.1 Limits.................................................................................................................................................................25 5.5.2 Test setup ..........................................................................................................................................................26 5.5.3 Test procedure...................................................................................................................................................27 5.5.4 Test results.........................................................................................................................................................28 5.5.4.1 Radiation emission .......................................................................................................................................28 5.5.4.2 Band edge - radiated ....................................................................................................................................32 5.5.4.3 Spurious Emission in Restricted Band 3260MHz-18000MHz ........................................................................34 5.6 BAND EDGE - CONDUCTED ...........................................................................................................................................35 5.6.1 Limits.................................................................................................................................................................35 5.6.2 Test setup ..........................................................................................................................................................35 5.6.3 Test procedure...................................................................................................................................................35 5.6.4 Test results.........................................................................................................................................................36 5.7 6DB BANDWIDTH .......................................................................................................................................................40 5.7.1 Limit ..................................................................................................................................................................40 5.7.2 Test setup ..........................................................................................................................................................40 5.7.3 Test procedure...................................................................................................................................................40 5.7.4 Test results.........................................................................................................................................................41 5.8 SPURIOUS RF CONDUCTED EMISSIONS ...........................................................................................................................49 5.8.1 Conformance Limit ............................................................................................................................................49 5.8.2 Measuring Instruments .....................................................................................................................................49 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 3 of 54 - Report No.: MTi19070107-6E1 5.8.3 Test Setup ..........................................................................................................................................................49 5.8.4 Test Procedure...................................................................................................................................................49 5.8.5 Test Results........................................................................................................................................................49 PHOTOGRAPHS OF THE TEST SETUP................................................................................................................................52 PHOTOGRAPHS OF THE EUT............................................................................................................................................54 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 4 of 54 - Report No.: MTi19070107-6E1 Test Result Certification Applicant's name: Address: Shenzhen Zhaoyang Tianxia Technology CO., Ltd. Room217, Building C1, Bantian International Center, Bantian Street, Longgang District, Shenzhen, China Manufacture's Name: Shenzhen Zhaoyang Shidai Technology Co., Ltd. Address: F6, Block F, JIN HENG RUN Industrial Park, Xintang, Fucheng Street, Longhua District, Shenzhen, China Product name: IP Camera Trademark: SV3C Model name: B08W-5MP-HX, B06W-3MP-HX, B06W-5MP-HX, B07W-1080P-HX, B08W-3MP-HX, B16VW-5MP-HX, SD5W-3MP-HX, SD5W-5MP-HX, SD7W-3MP-HX, SD7W-5MP-HX Standards: FCC Part 15.247 Test Procedure: ANSI C63.10-2013 KDB 558074 D01 DTS Meas Guidance v05r02 This device described above has been tested by Shenzhen Microtest Co., Ltd. and the test results show that the equipment under test (EUT) compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. Tested by: Jone Lee July 26, 2019 Reviewed by: Approved by: Blue Zheng Smith Chen Aug. 12, 2019 Aug. 12, 2019 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 5 of 54 - Report No.: MTi19070107-6E1 1 General information 1.1 Description of EUT Product name: Model name: Serial Model: Model difference: Operation frequency: Modulation type: Bit Rate of transmitter: Antenna type: Antenna gain: Max. output power: Power supply: Battery: Adapter information: Hardware version: Software version: IP Camera B08W-5MP-HX B06W-3MP-HX, B06W-5MP-HX, B07W-1080P-HX, B08W-3MP-HX, B16VW-5MP-HX, SD5W-3MP-HX, SD5W-5MP-HX, SD7W-3MP-HX, SD7W-5MP-HX All the model are the same circuit and RF module, except the pixel and model No.. 802.11b/g/n20:2412~2462 MHz 802.11n40:2422~2452 MHz IEEE 802.11b : DSSS (DBPSK, DQPSK, CCK) IEEE 802.11g/n (HT20/HT40) : OFDM (64QAM, 16QAM, QPSK, BPSK) 802.11b:11/5.5/2/1 Mbps 802.11g:54/48/36/24/18/12/9/6Mbps 802.11n(20MHz) use 800 ns GI: 65.0/58.5/52.0/39.0/26.0/19.5/13.0/6.5 Mbps (MCS0~MCS7) 802.11n(40MHz) use 800 ns GI: 13.5/27/40.5/54/81/108/121.5/135Mbps External Antenna 3.5dBi 13.73dBm DC 12V from adapter N/A Model:KA1201A-1201000US Input:100-240V 50/60Hz 0.4A Max Output: DC 12V 1000mA Hi3516EV300+sony335 V19.1.21.5.3-20190618 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 6 of 54 - Report No.: MTi19070107-6E1 1.2 Operation channel list Channel List for 802.11b/g/n(20) Channel 01 02 03 04 05 06 Frequency (MHz) 2412 2417 2422 2427 2432 2437 Channel 07 08 09 10 11 \ Frequency (MHz) 2442 2447 2452 2457 2462 \ Channel List for 802.11n(40) Channel 03 04 05 06 Frequency (MHz) 2422 2427 2432 2437 Channel 07 08 09 \ Frequency (MHz) 2442 2447 2452 \ 1.3 Test channel list Channel List for 802.11b/g/n(20) Channel Low Middle High Channel 01 06 11 Frequency (MHz) 2412 2437 2462 Channel List for 802.11n(40) Channel Low Middle High Channel 03 06 09 Frequency (MHz) 2422 2437 2452 1.4 Ancillary equipment list Equipment Mobile phone router Model / / S/N Manufacturer Certificate type / / / / / / 1.5 Description of Support Units The EUT has been tested as an independent unit together with other necessary accessories or support units. The following support units or accessories were used to form a representative test configuration during the tests. Item Equipment 1 Adapter Brand / Model/Type No. KA1201A-1201 000US Series No. / Note / Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 7 of 54 - Report No.: MTi19070107-6E1 / / / / / / Note: (1)The support equipment was authorized by Declaration of Confirmation. (2)For detachable type I/O cable should be specified the length in cm inLengthcolumn. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 8 of 54 - Report No.: MTi19070107-6E1 2 Summary of Test Results Test procedures according to the technical standards: No. Standard Section Test Item 1 15.203 Antenna Requirement 2 15.247 (b) Peak Output Power 3 15.247 (e) Power Spectral Density 4 15.207 Conducted Emission 5 15.247 (d) & 15.209 Radiated Spurious Emission 6 15.205 Band Edge Emission 7 15.247 (a)(2) 6dB Bandwidth 8 15.205 Spurious RF Conducted Emissions Result Pass Pass Pass Pass Pass Pass Pass Pass Remark Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 9 of 54 - Report No.: MTi19070107-6E1 3 Test Facilities and Accreditations 3.1 Test laboratory Test Laboratory Location FCC Registration No.: Shenzhen Microtest Co., Ltd No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China 448573 3.2 Environmental conditions Temperature: Humidity Atmospheric pressure 15ºC~35ºC 20%~75% 98kPa~101kPa 3.3 Measurement uncertainty The reported uncertainty of measurement y ±Uwhere expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2providing a level of confidence of approximately 95 % No. Item 1 Conducted Emission Test 2 RF power, conducted 3 Spurious emissions, conducted 4 All emissions, radiated(<1G) 5 All emissions, radiated(>1G) 6 Temperature 7 Humidity Uncertainty ±1.38dB ±0.16dB ±0.21dB ±4.68dB ±4.89dB ±0.5°C ±2% 3.4 Test software Software Name Manufacturer Bluetooth and WiFi Test Shenzhen JS tonscend System co., ltd Model JS1120-3 Version 2.5.77.0418 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 10 of 54 - Report No.: MTi19070107-6E1 4 Equipment list Equipment No. Equipment Name MTI-E004 EMI Test Receiver MTI-E006 TRILOG Broadband Antenna MTI-E014 amplifier MTI-E036 MTI-E038 Single path vehicle AMN(LISN) Low noise active vertical monopole antenna Manufactu rer Rohde&sch warz schwarabe ck Hewlett-Pa ckard Schwarzbe ck Schwarzbe ck MTI-E039 Biconical antenna Schwarzbe ck Model ESPI7 VULB 9163 8447D NNBM 8124 VAMP 9243 BBA 9106 Serial No. 100314 Calibration date Due date 2018/10/09 2019/10/08 9163-872 2018/10/15 2020/10/14 3113A061 50 2018/10/09 2019/10/08 01175 2018/10/09 2019/10/08 #565 2018/10/16 2019/10/15 #164 2018/10/15 2019/10/14 MTI-E041 MTI-E042 MTI-E044 MTI-E062 MTI-E063 MXG Vector Signal Generator ESG Series Analog signal generator Thermometer clock humidity monitor Log Periodic Antenna Log Periodic Dipole Array Antenna Agilent Agilent Schwarzbe ck ETS-LIND GREN N5182A E4421B HTC-1 MY49060 455 GB40051 240 / VUSLP 9111B #312 3148B 00224524 2019/04/16 2020/04/15 2019/05/21 2020/05/20 2019/04/17 2020/04/16 2018/04/11 2020/04/10 2018/04/11 2020/04/10 MTI-E065 Amplifier EMtrace RP06A 00117 2019/04/29 2020/04/28 MTI-E066 MTI-E071 MTI-E076 Comprehensive test instrument PXA Signal Analyzer EMI Test Receiver Rohde&sch warz Agilent Rohde&sch warz CMW500 N9030A ESIB26 149155 MY51350 296 100273 2019/04/16 2018/10/25 2019/04/16 2020/04/15 2019/10/24 2020/04/15 MTI-E078 Synthesized Sweeper Agilent 83752A 3610A019 57 2019/04/16 2020/04/15 MTI-E079 DC Power Supply Agilent E3632A MY40027 695 2019/04/16 2020/04/15 MTI-E093 Artificial mains network 3ctest LISN J50 ES391180 5 2019/04/16 2020/04/15 MTI-E096 MTI-E097 MTI-E098 MTI-E081 Power amplifier Current Probe Loop Sensor EPM Series Power Meter Space-Dtro niccs SOLAR ELECTRO NICS CO. SOLAR ELECTRO NICS CO. Agilent EWLNA0118G -P40 9207-1 7334-1 E4419B 1852001 220095-1 220095-2 MY50000 438 2019/04/29 2020/04/28 2019/04/17 2020/04/16 2019/04/21 2020/04/20 2019/4/16 2021/4/15 Note: the calibration interval of the above test instruments is 12 months and the calibrations are traceable to international system unit (SI). Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 11 of 54 - Report No.: MTi19070107-6E1 5 Test Result 5.1 Antenna requirement 5.1.1 Standard requirement 15.203 requirement: For intentional device, according to 15.203: an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device 5.1.2 EUT Antenna The EUT antenna is External antenna (3.5dBi). It comply with the standard requirement. In case of replacement of broken antenna the same antenna type must be used. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 12 of 54 - Report No.: MTi19070107-6E1 5.2 Peak output power 5.2.1 Limit Section 15.247(b)(3) 5.2.2 Test setup Test Item Peak output power Limit 1 watt or 30dBm EUT Attenuato r Frequency Range (MHz) 2400-2483.5 Power meter 5.2.3 Test procedure The EUT was directly connected to the Power meter. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China 5.2.4 Test results 802.11b Test Channel CH01 CH06 CH11 802.11g Test Channel CH01 CH06 CH11 802.11n20 Test Channel CH01 CH06 CH11 802.11n40 Test Channel CH03 CH06 CH09 Frequency (MHz) 2412 2437 2462 Frequency (MHz) 2412 2437 2462 Frequency (MHz) 2412 2437 2462 Frequency (MHz) 2422 2437 2452 - Page 13 of 54 - Report No.: MTi19070107-6E1 Maximum Peak Conducted Output Power(dBm) 13.38 13.53 12.84 Maximum Peak Conducted Output Power(dBm) 13.32 13.57 12.90 Maximum Peak Conducted Output Power(dBm) 13.73 13.51 12.93 Maximum Peak Conducted Output Power(dBm) 10.87 10.60 10.45 Limit (dBm) 30 30 30 Limit (dBm) 30 30 30 Limit (dBm) 30 30 30 Limit (dBm) 30 30 30 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 14 of 54 - Report No.: MTi19070107-6E1 5.3 Power spectral density 5.3.1 Limit Section Test Item 15.247(e) Power Spectral Density 5.3.2 Test Setup Limit 8 dBm (in any 3kHz) Frequency Range (MHz) 2400-2483.5 5.3.3 Test Procedure a. The EUT tested system was configured as the statements of 2.1 unless otherwise a special operating condition is specified in the follows during the testing. b. Set analyzer center frequency to DTS channel center frequency. c. Set the span to 1.5 times the DTS channel bandwidth. d. Set the RBW 3 kHz. e. Set the VBW 3 x RBW. f. Detector = peak. g. Sweep time = auto couple. h. Trace mode = max hold. i. Allow trace to fully stabilize. j. Use the peak marker function to determine the maximum amplitude level. k. If measured value exceeds limit, reduce RBW (no less than 3 kHz) and repeat. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 15 of 54 - Report No.: MTi19070107-6E1 5.3.4 Test Results Frequency 2412 MHz 2437 MHz 2462 MHz Power Density (dBm/3kHz) -15.052 -15.053 -16.023 802.11b Limit (dBm/3kHz) 8 8 8 Result Pass Pass Pass TX CH01 TX CH06 TX CH11 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 16 of 54 - Report No.: MTi19070107-6E1 802.11g Frequency Power Density (dBm/3kHz) 2412 MHz 2437 MHz 2462 MHz -12.978 -11.701 -13.473 TX CH01 Limit 8(dBm/3kHz) Result 8 Pass 8 Pass 8 Pass TX CH06 TX CH11 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 17 of 54 - Report No.: MTi19070107-6E1 Frequency 2412 MHz 2437 MHz 2462 MHz 802.11n20 Power Density (dBm/3kHz) -12.406 -12.078 -12.847 Limit 8(dBm/3kHz) 8 8 8 Result Pass Pass Pass TX CH01 TX CH06 TX CH11 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 18 of 54 - Report No.: MTi19070107-6E1 802.11n40 Frequency 2422 MHz 2437 MHz 2452 MHz Power Density (dBm/3kHz) -12.793 -12.299 -12.574 Limit 8(dBm/3kHz) 8 8 8 Result Pass Pass Pass TX CH03 TX CH06 TX CH9 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 19 of 54 - Report No.: MTi19070107-6E1 5.4 Conducted emission 5.4.1 Limits According to FCC Part 15.207(a) and KDB 174176 D01 Line Conducted FAQ v01r01. FREQUENCY (MHz) Class B (dBuV) Quasi-peak Average 0.15 -0.5 66 - 56 * 56 - 46 * 0.50 -5.0 56.00 46.00 5.0 -30.0 60.00 50.00 Note (1)The tighter limit applies at the band edges. (2)The limit of " * " marked band means the limitation decreases linearly with the logarithm of the frequency in the range. 5.4.2 Test setup Vertical Reference Ground Plane Test Receiver 40cm EUT LISN 80cm Horizontal Reference Ground Plane Note: 1.Support units were connected to second LISN. 2.Both of LISNs (AMN) are 80 cm from EUT and at least 80 cm from other units and other metal planes support. units. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 20 of 54 - Report No.: MTi19070107-6E1 5.4.3 Test procedure a. EUT Operating Conditions The EUT was configured for testing in a typical fashion (as a customer would normally use it). The EUT has been programmed to continuously transmit during test. This operating condition was tested and used to collect the included data. b. The following table is the setting of the receiver Receiver Parameters Attenuation Start Frequency Stop Frequency IF Bandwidth Setting 10 dB 0.15 MHz 30 MHz 9 kHz c. The EUT was placed 0.8 meters from the horizontal ground plane with EUT being connected to the power mains through a line impedance stabilization network (LISN). All other support equipments powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling impedance for the measuring instrument. d. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back and forth in the center forming a bundle 30 to 40 cm long. e. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the cable may be terminated, if required, using the correct terminating impedance. The overall length shall not exceed 1 m. f. LISN at least 80 cm from nearest part of EUT chassis. For the actual test configuration, please refer to the related Item EUT Test Photos. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 21 of 54 - Report No.: MTi19070107-6E1 5.4.4 Test results EUT Temperature Pressure Test Voltage IP Camera 26 1010hPa DC 12V from adapter AC 120V/60Hz Model Name. Relative Humidity Phase : Test Mode B08W-5MP-HX 54% L Charging+TX Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 22 of 54 - Report No.: MTi19070107-6E1 EUT Temperature Pressure Test Voltage IP Camera 26 1010hPa DC 12V from adapter AC 120V/60Hz Model Name. Relative Humidity Phase : Test Mode B08W-5MP-HX 54% N Charging+TX Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 23 of 54 - Report No.: MTi19070107-6E1 EUT Temperature Pressure Test Voltage IP Camera 26 1010hPa DC 12V from adapter AC 240V/50Hz Model Name. Relative Humidity Phase : Test Mode B08W-5MP-HX 54% L Charging+TX Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 24 of 54 - Report No.: MTi19070107-6E1 EUT Temperature Pressure Test Voltage IP Camera 26 1010hPa DC 12V from adapter AC 240V/50Hz Model Name. Relative Humidity Phase : Test Mode B08W-5MP-HX 54% N Charging+TX Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 25 of 54 - Report No.: MTi19070107-6E1 5.5 Radiated spurious 5.5.1 Limits 20dBc in any 100 kHz bandwidth outside the operating frequency band. In case the emission fall within the restricted band specified on 15.205(a), then the 15.209(a) limit in the table below has to be followed. Frequency Field Strength Measurement Distance (MHz) (micorvolts/meter) (meters) 0.009~0.490 2400/F(KHz) 300 0.490~1.705 24000/F(KHz) 30 1.705~30.0 30 30 30~88 100 3 88~216 150 3 216~960 200 3 Above 960 500 3 Spectrum Parameter Attenuation Start Frequency Stop Frequency RB / VB (emission in restricted band) Setting Auto 1000 MHz 10th carrier harmonic 1 MHz / 1 MHz for Peak, 1 MHz / 10Hz for Average Receiver Parameter Attenuation Start ~ Stop Frequency Start ~ Stop Frequency Start ~ Stop Frequency Setting Auto 9kHz~150kHz / RB 200Hz for QP 150kHz~30MHz / RB 9kHz for QP 30MHz~1000MHz / RB 120kHz for QP Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 26 of 54 - 5.5.2 Test setup Radiated emission test-up frequency below 30MHz Report No.: MTi19070107-6E1 Radiated emission test-up frequency 30MHz~1GHz Radiated emission test-up frequency above 1GHz 3m Turntabl e EUT 1.5 1.5 m m 4m Amplifie r Test Receiver Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 27 of 54 - Report No.: MTi19070107-6E1 5.5.3 Test procedure a. EUT operating conditions. The EUT tested system was configured as the statements of 2.4 unless otherwise a special operating condition is specified in the follows during the testing. b. The measuring distance of at 3 m shall be used for measurements at frequency up to 1GHz. For frequencies above 1GHz, any suitable measuring distance may be used. c. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter open area test site. The table was rotated 360 degrees to determine the position of the highest radiation. d. The height of the equipment or of the substitution antenna shall be 0.8 m; the height of the test antenna shall vary between 1 m to 4 m. Both horizontal and vertical polarizations of the antenna are set to make the measurement. e. For emission measurements above 1 GHz, the EUT shall be placed at a height of 1.5 m above the floor on a support that is RF transparent for the frequencies of interest. Final measurements for the EUT require a measurement antenna height scan of 1 m to 4 m. f. The initial step in collecting conducted emission data is a spectrum analyzer peak detector mode pre-scanning the measurement frequency range. Significant peaks are then marked and then Quasi Peak detector mode re-measured. g. If the Peak Mode measured value compliance with and lower than Quasi Peak Mode Limit, the EUT shall be deemed to meet QP Limits and then no additional QP Mode measurement performed. h. For the actual test configuration, please refer to the related Item EUT Test photos. Note: Both horizontal and vertical antenna polarities were tested and performed pretest to three orthogonal axis. The worst case emissions were reported Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 28 of 54 - Report No.: MTi19070107-6E1 5.5.4 Test results 5.5.4.1 Radiation emission Below 30MHz EUT IP Camera Relative Humidity: 52% Pressure 1010 hPa Test Mode TX Model Name Phase: Test Voltage B08W-5MP-HX H DC 12V from adapter AC 120V/60Hz Freq. Reading Limit Margin State (MHz) (dBuV/m) (dBuV/m) (dB) P/F -- -- -- -- Pass -- -- -- -- Pass Note: The amplitude of spurious emissions which are attenuated by more than 20dB below the permissible value has no need to be reported. Distance extrapolation factor =40 log (specific distance/test distance)(dB); Limit line = specific limits(dBuV) + distance extrapolation factor. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 29 of 54 - Report No.: MTi19070107-6E1 Between 30MHz 1GHz All the modulation modes have been tested, the report only shows the worst mode. The worst mode is 802.11n20 CH01, the worst result was report as below: EUT IP Camera Model Name B08W-5MP-HX Relative Humidity: Pressure Test Mode 52% 1010 hPa Charging+TX Phase: Test Voltage H DC 12V from adapter AC 120V/60Hz Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China EUT Relative Humidity: Pressure Test Mode IP Camera 52% 1010 hPa Charging+TX - Page 30 of 54 - Report No.: MTi19070107-6E1 Model Name Phase: Test Voltage B08W-5MP-HX V DC 12V from adapter AC 120V/60Hz Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 31 of 54 - Report No.: MTi19070107-6E1 1G-25GHz Note: (1) All Readings are Peak Value (VBW=3MHz) and AV Value (VBW=10Hz). (2) Emission Level= Antenna Factor + Cable Loss + Read Level - Preamp Factor (3) All other emissions more than 20dB below the limit. All the modulation modes have been tested, and the worst result was report as below: For 802.11b Frequency Read Level (MHz) (dBV) 4824.161 4824.161 7236.396 7236.396 4824.154 4824.154 7236.168 7236.168 63.28 40.93 59.77 43.38 60.96 42.88 62.79 46.54 4874.112 4874.112 7311.247 7311.247 4874.132 4874.132 7311.085 7311.085 63.05 42.42 59.53 47.43 60.46 47.84 59.40 41.28 4924.169 4924.169 7386.215 7386.215 4924.045 4924.045 7386.132 7386.132 65.66 42.94 60.67 44.43 67.19 47.27 60.61 44.80 Cable Antenna Preamp Emission Limits Margin Remark Comment loss Factor Factor Level (dB) dB/m (dB) (dBV/m) (dBV/m) (dB) Low Channel (2412 MHz)(802.11b)--Above 1G 4.36 32.92 45.53 55.03 74.00 -18.97 Pk Vertical 4.36 32.92 45.53 32.68 54.00 -21.32 AV Vertical 5.02 37.63 45.56 56.86 74.00 -17.14 Pk Vertical 5.02 37.63 45.56 40.47 54.00 -13.53 AV Vertical 4.36 32.92 45.53 52.71 74.00 -21.29 Pk Horizontal 4.36 32.92 45.53 34.63 54.00 -19.37 AV Horizontal 5.02 37.63 45.56 59.88 74.00 -14.12 Pk Horizontal 5.02 37.63 45.56 43.63 54.00 -10.37 AV Horizontal Middle Channel (2437 MHz)( 802.11b)--Above 1G 4.41 33.01 45.76 54.71 74.00 -19.29 Pk Vertical 4.41 33.01 45.76 34.08 54.00 -19.92 AV Vertical 5.02 37.68 45.59 56.64 74.00 -17.36 Pk Vertical 5.02 37.68 45.59 44.54 54.00 -9.46 AV Vertical 4.41 33.01 45.76 52.12 74.00 -21.88 Pk Horizontal 4.41 33.01 45.76 39.50 54.00 -14.50 AV Horizontal 5.02 37.68 45.59 56.51 74.00 -17.49 Pk Horizontal 5.02 37.68 45.59 38.39 54.00 -15.61 AV Horizontal High Channel (2462 MHz)( 802.11b)--Above 1G 4.50 33.26 46.07 57.35 74.00 -16.65 Pk Vertical 4.50 33.26 46.07 34.63 54.00 -19.37 AV Vertical 5.02 37.78 45.77 57.70 74.00 -16.30 Pk Vertical 5.02 37.78 45.77 41.46 54.00 -12.54 AV Vertical 4.50 33.26 46.07 58.88 74.00 -15.12 Pk Horizontal 4.50 33.26 46.07 38.96 54.00 -15.04 AV Horizontal 5.02 37.78 45.77 57.64 74.00 -16.36 Pk Horizontal 5.02 37.78 45.77 41.83 54.00 -12.17 AV Horizontal Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 32 of 54 - Report No.: MTi19070107-6E1 5.5.4.2 Band edge - radiated Note: (1) All Readings are Peak Value (VBW=3MHz) and AV Value (VBW=10Hz). (2)Emission Level= Antenna Factor + Cable Loss + Read Level - Preamp Factor (3) All other emissions more than 20dB below the limit. Frequency Meter Reading (MHz) (dBV) 2310.00 2310.00 2310.00 2310.00 2390.00 2390.00 2390.00 2390.00 2483.50 2483.50 2483.50 2483.50 56.35 43.69 58.29 42.39 57.36 42.36 57.00 41.49 58.12 43.50 58.83 41.45 2310.00 2310.00 2310.00 2310.00 2390.00 2390.00 2390.00 2390.00 2483.50 2483.50 2483.50 2483.50 58.97 43.73 56.68 42.54 57.52 41.99 58.23 43.38 59.23 44.01 58.38 42.00 Cable Loss (dB) 2.40 2.40 2.40 2.40 2.44 2.44 2.44 2.44 2.48 2.48 2.48 2.48 2.40 2.40 2.40 2.40 2.44 2.44 2.44 2.44 2.48 2.48 2.48 2.48 Antenna Preamp Emission Limits Margin Factor Factor Level dB/m (dB) (dBV/m) (dBV/m) (dB) 802.11b 27.70 40.40 46.05 74 -27.95 27.70 40.40 33.39 54 -20.61 27.70 40.40 47.99 74 -26.01 27.70 40.40 32.09 54 -21.91 28.30 40.10 48.00 74 -26.00 28.30 40.10 33.00 54 -21.00 28.30 40.10 47.64 74 -26.36 28.30 40.10 32.13 54 -21.87 28.70 39.80 49.50 74 -24.50 28.70 39.80 34.88 54 -19.12 28.70 39.80 50.21 74 -23.79 28.70 39.80 32.83 54 -21.17 802.11g 27.70 40.40 48.67 74 -25.33 27.70 40.40 33.43 54 -20.57 27.70 40.40 46.38 74 -27.62 27.70 40.40 32.24 54 -21.76 28.30 40.10 48.16 74 -25.84 28.30 40.10 32.63 54 -21.37 28.30 40.10 48.87 74 -25.13 28.30 40.10 34.02 54 -19.98 28.70 39.80 50.61 74 -23.39 28.70 39.80 35.39 54 -18.61 28.70 39.80 49.76 74 -24.24 28.70 39.80 33.38 54 -20.62 Detector Comment Type Pk Horizontal AV Horizontal Pk Vertical AV Vertical Pk Vertical AV Vertical Pk Horizontal AV Horizontal Pk Vertical AV Vertical Pk Horizontal AV Horizontal Pk Horizontal AV Horizontal Pk Vertical AV Vertical Pk Vertical AV Vertical Pk Horizontal AV Horizontal Pk Vertical AV Vertical Pk Horizontal AV Horizontal Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 33 of 54 - Report No.: MTi19070107-6E1 2310.00 2310.00 2310.00 2310.00 2390.00 2390.00 2390.00 2390.00 2483.50 2483.50 2483.50 2483.50 58.48 43.64 59.20 42.12 57.57 42.27 56.61 41.96 58.24 42.72 58.63 41.88 2310.00 2310.00 2310.00 2310.00 2390.00 2390.00 2390.00 2390.00 2483.50 2483.50 2483.50 2483.50 59.11 44.89 56.87 43.84 58.14 41.78 58.08 43.47 58.15 43.73 58.24 42.46 802.11n20 2.40 27.70 40.40 48.18 2.40 27.70 40.40 33.34 2.40 27.70 40.40 48.90 2.40 27.70 40.40 31.82 2.44 28.30 40.10 48.21 2.44 28.30 40.10 32.91 2.44 28.30 40.10 47.25 2.44 28.30 40.10 32.60 2.48 28.70 39.80 49.62 2.48 28.70 39.80 34.10 2.48 28.70 39.80 50.01 2.48 28.70 39.80 33.26 802.11n40 2.40 27.70 40.40 48.81 2.40 27.70 40.40 34.59 2.40 27.70 40.40 46.57 2.40 27.70 40.40 33.54 2.44 28.30 40.10 48.78 2.44 28.30 40.10 32.42 2.44 28.30 40.10 48.72 2.44 28.30 40.10 34.11 2.48 28.70 39.80 49.53 2.48 28.70 39.80 35.11 2.48 28.70 39.80 49.62 2.48 28.70 39.80 33.84 74 -25.82 Pk Horizontal 54 -20.66 AV Horizontal 74 -25.10 Pk Vertical 54 -22.18 AV Vertical 74 -25.79 Pk Vertical 54 -21.09 AV Vertical 74 -26.75 Pk Horizontal 54 -21.40 AV Horizontal 74 -24.38 Pk Vertical 54 -19.90 AV Vertical 74 -23.99 Pk Horizontal 54 -20.74 AV Horizontal 74 -25.19 Pk Horizontal 54 -19.41 AV Horizontal 74 -27.43 Pk Vertical 54 -20.46 AV Vertical 74 -25.22 Pk Vertical 54 -21.58 AV Vertical 74 -25.28 Pk Horizontal 54 -19.89 AV Horizontal 74 -24.47 Pk Vertical 54 -18.89 AV Vertical 74 -24.38 Pk Horizontal 54 -20.16 AV Horizontal Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 34 of 54 - Report No.: MTi19070107-6E1 5.5.4.3 Spurious Emission in Restricted Band 3260MHz-18000MHz All the modulation modes have been tested, and the worst result was report as below: Frequency Reading Cable Antenna Preamp Emission Limits Margin Level Loss Factor Factor Level (MHz) (dBV) (dB) dB/m (dB) (dBV/m) (dBV/m) (dB) Detector Type 3260 3260 3260 3260 3332 3332 3332 60.62 3.27 30.02 38.05 55.24 3.27 30.02 38.05 61.45 3.27 30.02 38.05 55.10 3.27 30.02 38.05 64.56 3.31 30.00 37.91 54.09 3.31 30.00 37.91 63.04 3.31 30.00 37.91 55.86 50.48 56.69 50.34 59.96 49.49 58.44 74 -18.14 Pk 54 -3.52 AV 74 -17.31 Pk 54 -3.66 AV 74 -14.04 Pk 54 -4.51 AV 74 -15.56 Pk 3332 17797 17797 17788 17788 52.79 3.31 30.00 37.91 43.03 8.63 44.23 39.60 32.38 8.63 44.23 39.60 44.11 8.63 44.23 39.60 31.96 8.63 44.23 39.60 48.19 56.29 45.64 57.37 45.22 54 -5.81 AV 74 -17.71 Pk 54 -8.36 AV 74 -16.63 Pk 54 -8.78 AV Comment Vertical Vertical Horizontal Horizontal Vertical Vertical Horizontal Horizontal Vertical Vertical Horizontal Horizontal Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 35 of 54 - Report No.: MTi19070107-6E1 5.6 Band edge - Conducted 5.6.1 Limits In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement, provided the transmitter demonstrates compliance with the peak conducted power limits. If the transmitter complies with the conducted power limits based on the use of RMS averaging over a time interval, as permitted under paragraph (b)(3) of this section, the attenuation required under this paragraph shall be 30 dB instead of 20 dB. Attenuation below the general limits specified in §15.209(a) is not required. In addition, radiated emissions which fall in the restricted bands, as defined in §15.205(a), must also comply with the radiated emission limits specified in §15.209(a) (see §15.205(c)). 5.6.2 Test setup 5.6.3 Test procedure a) Check the calibration of the measuring instrument using either an internal calibrator or a known signal from an external generator. b) Position the EUT without connection to measurement instrument. Turn on the EUT and connect its antenna terminal to measurement instrument via a low loss cable. Then set it to any one measured frequency within its operating range, and make sure the instrument is operated in its linear range. c) Set RBW to 100 kHz and VBW of spectrum analyzer to 300 kHz with a convenient frequency span including 100 kHz bandwidth from band edge. d) Measure the highest amplitude appearing on spectral display and set it as a reference level. Plot the graph with marking the highest point and edge frequency. e) Repeat above procedures until all measured frequencies were complete. EUT OPERATION CONDITIONS The EUT tested system was configured as the statements of 2.4 unless otherwise a special operating condition is specified in the follows during the testing. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China 5.6.4 Test results Test plots: - Page 36 of 54 - Report No.: MTi19070107-6E1 802.11b: Band Edge, Left Side 802.11b: Band Edge, Right Side Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 37 of 54 - 802.11g: Band Edge, Left Side Report No.: MTi19070107-6E1 802.11g: Band Edge, Right Side Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 38 of 54 - Report No.: MTi19070107-6E1 802.11n20: Band Edge, Left Side 802.11n20: Band Edge, Right Side Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 39 of 54 - Report No.: MTi19070107-6E1 802.11n40: Band Edge, Left Side 802.11n40: Band Edge, Right Side Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 40 of 54 - Report No.: MTi19070107-6E1 5.7 6dB bandwidth 5.7.1 Limit Section 15.247(a)(2) 5.7.2 Test setup Test Item Bandwidth Limit >= 500KHz (6dB bandwidth) Frequency Range (MHz) 2400-2483.5 5.7.3 Test procedure a. Set RBW= 100 kHz. b. Set the video bandwidth (VBW) 3 x RBW. c. Detector = Peak. d. Trace mode = max hold. e. Sweep = auto couple. f. Allow the trace to stabilize. g. Measure the maximum width of the emission that is constrained by the frequencies associated with the two outermost amplitude points (upper and lower) that are attenuated by 6 dB relative to the maximum level measured in the fundamental emission. EUT Operation Conditions The EUT tested system was configured as the statements of 2.4 unless otherwise a special operating condition is specified in the follows during the testing. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China 5.7.4 Test results - Page 41 of 54 - Report No.: MTi19070107-6E1 EUT Temperature Pressure Test Mode IP Camera Model Name B08W-5MP-HX 25 1012 hPa Relative Humidity 60% Test Voltage DC 12V from adapter AC 120V/60Hz TX b Mode /CH01, CH06, CH11 Channel Low Middle High Frequency (MHz) 2412 2437 2462 6dB bandwidth (MHz) 10.11 10.08 10.10 TX CH 01 Limit (kHz) 500 500 500 Result Pass Pass Pass Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 42 of 54 - TX CH 06 Report No.: MTi19070107-6E1 TX CH 11 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 43 of 54 - Report No.: MTi19070107-6E1 EUT Temperature Pressure Test Mode IP Camera Model Name B08W-5MP-HX 25 1012 hPa Relative Humidity 60% Test Voltage DC 12V from adapter AC 120V/60Hz TX g Mode /CH01, CH06, CH11 Channel Low Middle High Frequency (MHz) 2412 2437 2462 6dB bandwidth (MHz) 16.41 16.40 16.38 TX CH 01 Limit (kHz) 500 500 500 Result Pass Pass Pass Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 44 of 54 - TX CH 06 Report No.: MTi19070107-6E1 TX CH 11 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 45 of 54 - Report No.: MTi19070107-6E1 EUT Temperature Pressure Test Mode IP Camera Model Name B08W-5MP-HX 25 1012 hPa Relative Humidity 60% Test Voltage DC 12V from adapter AC 120V/60Hz TX n20 Mode /CH01, CH06, CH11 Channel Low Middle High Frequency (MHz) 2412 2437 2462 6dB bandwidth (MHz) 17.35 17.32 16.93 TX CH 01 Limit (kHz) 500 500 500 Result Pass Pass Pass Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 46 of 54 - TX CH 06 Report No.: MTi19070107-6E1 TX CH 11 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 47 of 54 - Report No.: MTi19070107-6E1 EUT Temperature Pressure Test Mode IP Camera Model Name B08W-5MP-HX 25 Relative Humidity 60% 1012 hPa Test Voltage DC 12V from adapter AC 120V/60Hz TX n40 Mode /CH03, CH06, CH09 Channel Low Middle High Frequency (MHz) 2422 2437 2452 6dB bandwidth (MHz) 35.31 35.19 35.15 TX CH 03 Limit (kHz) 500 500 500 Result Pass Pass Pass Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 48 of 54 - TX CH 06 Report No.: MTi19070107-6E1 TX CH 09 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 49 of 54 - Report No.: MTi19070107-6E1 5.8 Spurious RF Conducted Emissions 5.8.1 Conformance Limit Below -20dB of the highest emission level in operating band. 5.8.2 Measuring Instruments The Measuring equipment is listed in the section 6.3 of this test report. 5.8.3 Test Setup Please refer to Section 6.1 of this test report. 5.8.4 Test Procedure The Spurious RF conducted emissions compliance of RF radiated emission should be measured by following the guidance in ANSI C63.10-2013 with respect to maximizing the emission by rotating the EUT, measuring the emission while the EUT is situated in three orthogonal planes (if appropriate), adjusting the measurement antenna height and polarization etc. Set RBW=100kHz and VBW= 300KHz to measure the peak field strength, and measure frequency range from 9KHz to 26.5GHz. 5.8.5 Test Results Remark: The measurement frequency range is from 9KHz to the 10th harmonic of the fundamental frequency. The lowest, middle and highest channels are tested to verify the spurious emissions and band edge measurement data. Note1: The three modulated high, medium and low channels have been tested. The report only shows the worst mode. The worst mode is 802.11n20. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 50 of 54 - Report No.: MTi19070107-6E1 802.11n20 on Channel 01 802.11n20 on Channel 01 802.11n20 on Channel 01 802.11n20 on Channel 06 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China 802.11n20 on Channel 06 - Page 51 of 54 - Report No.: MTi19070107-6E1 802.11n20 on Channel 06 802.11n20 on Channel 11 802.11n20 on Channel 11 802.11n20 on Channel 11 / / Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photographs of the Test Setup - Page 52 of 54 - Radiated emission Report No.: MTi19070107-6E1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 53 of 54 - Conducted emission Report No.: MTi19070107-6E1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China - Page 54 of 54 - Report No.: MTi19070107-6E1 Photographs of the EUT See the APPENDIX 1: EUT PHOTO in the report No.: MTi19070107-6E1-1. ----END OF REPORT---- Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, ChinaMicrosoft Word 2016 Microsoft Word 2016