IMPORTANT NOTE: Thank you for purchasing our air conditioner. Please read this manual carefully before operating your new air conditioning unit. Make sure to save this manual for future reference.

Remote Controller Specifications

ModelRG51A(2)/E, RG51A(2)/EU1, RG51A(2)/CE, RG51A10(2)/E, RG51B(2)/E, RG51B(2)/EU1, RG51B(2)/CE, RG51B10(2)/E, RG51B10(2)/CE, RG51Y7(2)/E, RG51Y8(2)/E
Rated Voltage3.0V (Dry batteries R03/LR03×2)
Signal Receiving Range8m
Environment-5°C~60°C (23°F~140°F)

NOTE: For models of RG51Y7(2)/E and RG51Y8(2)/E, if the unit is turned off under COOL, AUTO, or DRY mode with the set temperature less than 24°C, the set temperature will be automatically set to 24°C when you turn on the unit again. If the unit is turned off under HEAT mode with the set temperature more than 24°C, the set temperature will be automatically set to 24°C when you turn on the unit again.

Quick Start Guide

  1. FIT BATTERIES: Slide the back cover from the remote control downward to expose the battery compartment. Insert batteries, matching the (+) and (-) ends with the symbols inside. Slide the cover back into place.
  2. SELECT MODE: Press the [MODE] button to cycle through operation modes: AUTO, COOL, DRY, HEAT, FAN.
  3. SELECT TEMPERATURE: Use the [TEMP ▲] or [TEMP ▼] buttons to set the desired temperature.
  4. SELECT FAN SPEED: Press the [FAN SPEED] button to select fan speed: AUTO, LOW, MED, HIGH.
  5. POINT REMOTE TOWARD UNIT: Ensure the remote is pointed towards the air conditioning unit.
  6. PRESS POWER BUTTON: Press the [ON/OFF] button to start the unit.

NOT SURE WHAT A FUNCTION DOES? Refer to the "How to Use Basic Functions" and "How to Use Advanced Functions" sections of this manual for a detailed description.

SPECIAL NOTE

Handling the Remote Controller

Inserting and Replacing Batteries

Your air conditioning unit may come with two batteries (some units). Put the batteries in the remote control before use.

  1. Slide the back cover from the remote control downward, exposing the battery compartment.
  2. Insert the batteries, paying attention to match up the (+) and (-) ends of the batteries with the symbols inside the battery compartment.
  3. Slide the battery cover back into place.

BATTERY NOTES

BATTERY DISPOSAL

Do not dispose of batteries as unsorted municipal waste. Refer to local laws for proper disposal of batteries.

TIPS FOR USING REMOTE CONTROL

CAUTIONS FOR USING REMOTE CONTROL

The device could comply with local national regulations.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Consult the dealer or an experienced radio/TV technician for help.

Changes or modifications not expressly approved by the party responsible for compliance could void user's authority to operate the equipment.

Buttons and Functions

Before you begin using your new air conditioner, make sure to familiarize yourself with its remote control. The following is a brief introduction to the remote control itself. For instructions on how to operate your air conditioner, refer to the "How to Use Basic Functions" section of this manual.

Remote Control Layout and Functions

Model: RG51A(2)/E, RG51A(2)/EU1, RG51Y7(2)/E, RG51A10(2)/E (20-28°C/68-82°F); RG51A(2)/CE (Cooling only models, AUTO mode and HEAT mode are not available)

Model: RG51B(2)/E, RG51B(2)/EU1, RG51Y8(2)/E, RG51B10(2)/E & RG51B10(2)/CE (20-28°C/68-82°F); RG51B(2)/CE & RG51B10(2)/CE (Cooling only models, AUTO mode and HEAT mode are not available)

Remote Screen Indicators

Information is displayed when the remote controller is powered up.

Mode Display

Fan Speed Indication

Note: All indicators shown in the figure are for the purpose of clear presentation. But during actual operation, only the relative function signs are shown on the display window.

How to Use Basic Functions

Basic Operation

ATTENTION! Before operation, please ensure the unit is plugged in and power is available.

SETTING TEMPERATURE

The operating temperature range for units is 16-30°C (60-86°F) / 20-28°C (68-82°F). You can increase or decrease the set temperature in 1°C (1°F) increments.

AUTO Mode

In AUTO mode, the unit will automatically select the COOL, FAN, or HEAT operation based on the set temperature.

  1. Press the [MODE] button to select AUTO.
  2. Set your desired temperature using the [TEMP ▲] or [TEMP ▼] button.
  3. Press the [ON/OFF] button to start the unit.

NOTE: FAN SPEED can't be set in AUTO mode.

COOL Mode

  1. Press the [MODE] button to select COOL mode.
  2. Set your desired temperature using the [TEMP ▲] or [TEMP ▼] button.
  3. Press the [FAN SPEED] button to select the fan speed: AUTO, LOW, MED or HIGH.
  4. Press the [ON/OFF] button to start the unit.

How to Use Basic Functions (Continued)

DRY Mode (dehumidifying)

  1. Press the [MODE] button to select DRY.
  2. Set your desired temperature using the [TEMP ▲] or [TEMP ▼] button.
  3. Press the [ON/OFF] button to start the unit.

NOTE: FAN SPEED cannot be changed in DRY mode.

FAN Mode

  1. Press the [MODE] button to select FAN mode.
  2. Press the [FAN SPEED] button to select the fan speed: AUTO, LOW, MED or HIGH.
  3. Press the [ON/OFF] button to start the unit.

NOTE: You can't set temperature in FAN mode. As a result, your remote control's LCD screen will not display temperature.

HEAT Mode

  1. Press the [MODE] button to select HEAT mode.
  2. Set your desired temperature using the [TEMP ▲] or [TEMP ▼] button.
  3. Press the [FAN SPEED] button to select the fan speed: AUTO, LOW, MED or HIGH.
  4. Press the [ON/OFF] button to start the unit.

NOTE: As outdoor temperature drops, the performance of your unit's HEAT function may be affected. In such instances, we recommend using this air conditioner in conjunction with other heating appliances.

Setting the TIMER

TIMER ON/OFF - Set the amount of time after which the unit will automatically turn on/off.

TIMER ON Setting

  1. Press the [TIMER ON] button to initiate the ON time sequence.
  2. Press [TEMP ▲] or [TEMP ▼] buttons multiple times to set the desired time to turn on the unit.
  3. Point the remote to the unit and wait 1 second; the TIMER ON will be activated.

TIMER OFF Setting

  1. Press the [TIMER OFF] button to initiate the OFF time sequence.
  2. Press [TEMP ▲] or [TEMP ▼] buttons multiple times to set the desired time to turn off the unit.
  3. Point the remote to the unit and wait 1 second; the TIMER OFF will be activated.

NOTE:

  1. When setting the TIMER ON or TIMER OFF, the time will increase by 30-minute increments with each press, up to 10 hours. After 10 hours and up to 24, it will increase in 1-hour increments. (For example, press 5 times to get 2.5h, and press 10 times to get 5h.) The timer will revert to 0.0 after 24.
  2. Cancel either function by setting its timer to 0.0h.

TIMER ON & OFF Setting (Example)

Keep in mind that the time periods you set for both functions refer to hours after the current time.

Example: If the current time is 1:00 PM, to set the timer as above steps, the unit will turn on 2.5 hours later (3:30 PM) and turn off at 6:00 PM.

How to Use Advanced Functions

Swing Function

Press the [SWING] button. The horizontal louver will swing up and down automatically. Press again to make it stop.

Keep pressing the [SWING] button for more than 2 seconds; the vertical louver swing function is activated (Model dependent).

Airflow Direction

Each time you press the [DIRECT] button, it will adjust the louver by 6°. Press the button until the direction you prefer is reached.

LED DISPLAY

Press the [LED DISPLAY] button to turn on and turn off the display on the indoor unit.

Press this button for more than 5 seconds (some units). The indoor unit will display the actual room temperature. Press for more than 5 seconds again to revert back to displaying the setting temperature.

Advanced Functions (Continued)

ECO Function

Press this button under COOL Mode to enter the energy efficient mode. (For models RG51A(2)/E, RG51A(2)/EU1, RG51A(2)/CE, RG51A10(2)/E, RG51Y7(2)/E)

Note: This function is only available under COOL mode.

Under cooling mode, pressing this button adjusts the temperature automatically to 24°C/75°F and fan speed to Auto to save energy (only when the set temperature is less than 24°C/75°F). If the set temperature is above 24°C/75°F, pressing the [ECO] button changes the fan speed to Auto, while the set temperature remains unchanged.

NOTE: Pressing the [ECO] button, or modifying the mode, or adjusting the set temperature to less than 24°C/75°F will stop ECO operation. Under ECO operation, the set temperature should be 24°C/75°F or above; otherwise, it may result in insufficient cooling. If you feel uncomfortable, just press the [ECO] button again to stop it.

SHORTCUT Function

Used to restore the current settings or resume previous settings. (For models RG51B(2)/E, RG51B(2)/EU1, RG51B(2)/CE, RG51B10(2)/E, RG51B10(2)/CE, RG51Y8(2)/E)

Push this button when the remote controller is on; the system will automatically revert back to the previous settings including operating mode, setting temperature, fan speed level, and sleep feature (if activated). If pushing for more than 2 seconds, the system will automatically restore the current operation settings including operating mode, setting temperature, fan speed level, and sleep feature (if activated).

SLEEP Function

The [SLEEP] function is used to decrease energy use while you sleep (and don't need the same temperature settings to stay comfortable). This function can only be activated via remote control. The sleep function is not available in Fan or Dry mode. Please refer to the OWNER'S MANUAL for more details.

Additional Functions

Silence Function

Keep pressing the [FAN SPEED] button for more than 2 seconds to activate/disable Silence function (some units).

Due to low frequency operation of the compressor, it may result in insufficient cooling and heating capacity. Pressing [ON/OFF], [MODE], [SLEEP], [TURBO], or [CLEAN] buttons while operating will cancel the silence function.

FP Function

The unit will operate at high fan speed (while compressor is on) with the temperature automatically set to 8°C/46°F.

Note: This function is for heat pump air conditioner only. Press the [FP] button 2 times within one second under HEAT Mode and setting temperature of 16°C/60°F or 20°C/68°F (for models RG51A10(2)/E, RG51B10(2)/E, RG51B10(2)/CE) to activate FP function. Pressing [ON/OFF], [SLEEP], [MODE], [FAN SPEED], and [TEMP] buttons while operating will cancel this function.

Contact Information & Disclaimer

The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details.

Model Number: CR256-RG51A-B(2)

Koppel, Inc.

A Tradition of leadership and excellence for over 50 years

Koppel Head Office:

106 Industry Drive, Carmelray Industrial Park I, Brgy. Canlubang, Calamba City, Laguna 4028

Tel no: (02) 8823-88-83

Website: www.koppel.ph

Iloilo Office:

NSB Bldg., Rizal Street, Iloilo City

Tel No.: (033) 330-2926

Cel No.: 0933-867-2907

Cebu Office:

A. Cortez Avenue, Mandaue City

Tel No.: (032) 346-7279

Fax No.: (032) 346-7865

Davao Office:

J.P. Cabaguio Avenue, Davao City

Tel Nos.: (082) 221-6419

Fax No.: (082) 221-6418

Cagayan De Oro Office:

2nd Floor 28-B, Brgy. Cugman, Cagayan De Oro City

Tel Nos.: (088) 880-6326

*All specifications are subject to change without prior notice for continuous product improvement. PDED REV. No.: 01-0419

Models: RG51A Ceiling Cassette Super Inverter, RG51A, Ceiling Cassette Super Inverter, Cassette Super Inverter, Super Inverter, Inverter

File Info : application/pdf, 16 Pages, 3.48MB

PDF preview unavailable. Download the PDF instead.

Koppel-Ceiling-Cassette-Super-Inverter-Remote-Controller-Manual-KV60CC-ARF21D Adobe PDF library 10.01 Adobe Illustrator CS6 (Windows)

Related Documents

PreviewKoppel Remote Controller Owner's Manual
This owner's manual provides detailed instructions for operating the Koppel remote controller for air conditioning units, covering basic and advanced functions, specifications, and troubleshooting.
PreviewKoppel Air Conditioner Remote Controller Owner's Manual
This owner's manual provides comprehensive instructions for operating and understanding the Koppel remote controller for air conditioning units, covering basic and advanced functions, specifications, and handling tips.
PreviewKoppel Remote Controller Owner's Manual
This owner's manual provides detailed information on the Koppel remote controller for air conditioning units, including specifications, button functions, screen indicators, and operating instructions for basic and advanced features.
PreviewKoppel Remote Controller Owner's Manual: Features and Operation
Comprehensive owner's manual for Koppel remote controllers, detailing specifications, button functions, screen indicators, basic and advanced operation modes, and timer settings for Koppel air conditioning units.
PreviewKoppel Ceiling Concealed Inverter Air Conditioner Specifications and Features
Explore the Koppel Ceiling Concealed Inverter air conditioner series, featuring models KV36DH, KV48DH, and KV60DH. This brochure details key specifications, performance data, and essential features like R410A refrigerant, self-diagnosis, 24-hour timer, anti-rust body, wired remote control, and auto protection for efficient cooling solutions.
PreviewKoppel Window Type Room Air Conditioner User's Manual - Operation, Installation, Safety
Comprehensive user's manual for Koppel Window Type Room Air Conditioners (KWR-09R4A2, KWR-12R4A2, KWR-18R4A2). Learn about safety precautions, operating instructions, installation guides, troubleshooting tips, and technical specifications.
PreviewKoppel Wall Mounted Super Inverter III: Energy-Efficient Air Conditioning Specifications
Discover the Koppel Wall Mounted Super Inverter III air conditioner series, featuring advanced technologies like ECO MODE, 3D Airflow, 4D Air Cleaning, and Refrigerant Leakage Detection. This brochure provides detailed technical specifications for various models, highlighting energy savings and performance.
PreviewKoppel Super iMatch Multi Split Type Inverter Air Conditioner Specifications and Features
Explore the Koppel Super iMatch Multi Split Type Inverter air conditioner, featuring advanced technology for flexible cooling, energy savings, and individual room control. View detailed specifications and features for various models.