Shenzhen Zidoo Technology Co., Ltd. ZD24P 8K UHD MEDIA PLAYER 2AGN7-ZD24P 2AGN7ZD24P zd24p
Page 1 of 38 Report No.: AITSZ24052403FW1 TEST REPORT Client Information: Applicant: Shenzhen Zidoo Technology Co., Ltd. Room 1301,1302,1303,1307, Chentian R&D Building, No. 50 Baotian First Road, Applicant add.: Chentian Community, Xixiang Street, Baoan District, Shenzhen, China Manufacturer: Shenzhen Zidoo Technology Co., Ltd. Room 1301,1302,1303,1307, Chentian R&D Building, No. 50 Baotian First Road, Manufacturer add.: Chentian Community, Xixiang Street, Baoan District, Shenzhen, China Product Information: Product Name: 8K UHD MEDIA PLAYER Model No.: ZD24P Serial Model: UHD8000,Z3000 PRO Brand Name: ZIDOO Test samples.: AITSZ24052403-1 FCC ID: 2AGN7-ZD24P Applicable standards: FCC CFR Title 47 Part 15 Subpart C Section 15.247 Prepared By: Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel.: +86 0755-230967639 Fax.: +86 0755-230967639 Date of Receipt: May 24, 2024 Date of Test: May 24, 2024 ~ July. 01, 2024 Date of Issue: July. 01, 2024 Test Result: Pass This device described above has been tested by Guangdong Asia Hongke Test Technology Limited and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. Note: This report shall not be reproduced except in full, without the written approval of Guangdong Asia Hongke Test Technology Limited, this document may be altered or revised by Guangdong Asia Hongke Test Technology Limited, personal only, and shall be noted in the revision of the document. This test report must not be used by the client to claim product endorsement. Reviewed by: Leon.yi Approved by: Sean She Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Page 2 of 38 Report No.: AITSZ24052403FW1 1 Contents COVER PAGE Page 1 CONTENTS .................................................................................................................................................................... 2 2 TEST SUMMARY .......................................................................................................................................................... 4 2.1 Statement of the Measurement Uncertainty ....................................................................................... 4 2.2 Measurement Uncertainty ................................................................................................................... 4 3 TEST FACILITY ............................................................................................................................................................. 5 3.1 Deviation from standard ...................................................................................................................... 5 3.2 Abnormalities from standard conditions .............................................................................................. 5 3.3 Test Location ....................................................................................................................................... 5 4 GENERAL INFORMATION ......................................................................................................................................... 6 4.1 Test frequencies .................................................................................................................................. 7 4.2 EUT Peripheral List ............................................................................................................................. 8 4.3 Test Peripheral List .............................................................................................................................. 8 4.4 TEST METHODOLOGY ...................................................................................................................... 9 4.5 Description of Test Modes ................................................................................................................. 10 5 EQUIPMENT USED DURING TEST ........................................................................................................................ 11 6 TEST RESULTS AND MEASUREMENT DATA .................................................................................................... 12 6.1 Antenna requirement ......................................................................................................................... 12 6.2 Peak Power Measurement ................................................................................................................ 13 6.3 Frequency Separation and 20 dB Bandwidth ................................................................................... 15 6.4 Number of Hopping Frequency ......................................................................................................... 17 6.5 Time of Occupancy (Dwell Time) ...................................................................................................... 18 6.6 Conducted Spurious Emissions and Band Edges Test..................................................................... 20 6.7 Radiated Emissions and Radiation Restricted band Measurement ................................................. 22 6.8 Conducted Emissions........................................................................................................................ 34 6.9 Pseudorandom frequency hopping sequence .................................................................................. 37 7 TEST SETUP PHOTOGRAPHS OF EUT................................................................................................................ 38 8 EXTERNAL PHOTOGRAPHS OF EUT................................................................................................................... 38 9 INTERNAL PHOTOGRAPHS OF EUT .................................................................................................................... 38 Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Revision 01 Page 3 of 38 Revision History Report No.: AITSZ24052403FW1 Issue Date July. 01, 2024 Revisions Initial Issue Revised By Sean She Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Page 4 of 38 Report No.: AITSZ24052403FW1 2 Test Summary Test Item Section in CFR 47 Result Maximum Conducted Output Power §15.247(b) Pass 20dB Bandwidth §15.247(a) Pass Frequency Separation §15.247(a) Pass Number Of Hopping Frequency Time Of Occupancy (Dwell Time) Conducted Spurious Emissions and Band Edges Emissions Radiated Spurious Emissions §15.247(a) §15.247(a) §15.205, §15.247(d) §15.209, §15.247(d) Pass Pass Pass Pass Emissions at Restricted Band §15.205 Pass AC Mains Conducted Emissions §15.207(a) Pass Antenna Requirements §15.203 Note 1. Test according to ANSI C63.10:2013 and RSS-Gen. 2. The measurement uncertainty is not included in the test result. 3. Test results in other test report (RF Exposure Evaluation Report) Pass 2.1 Statement of the Measurement Uncertainty The data and results referenced in this document are true and accurate. The reader is cautioned that there may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was calculated for all measurements listed in this test report acc. To CISPR 16 4 "Specification for radio disturbance and immunity measuring apparatus and methods Part 4: Uncertainty in EMC Measurements" and is documented in the AiT quality system acc. To DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar to that tested may result in additional deviation. The manufacturer has the sole responsibility of continued compliance of the device. 2.2 Measurement Uncertainty Test Item Frequency Range Measurement Uncertainty Notes Radiated Emission 0.009MHz-30MHz 3.10dB (1) Radiated Emission 30MHz-1GHz 3.75dB (1) Radiated Emission 1GHz-18GHz 3.88dB (1) Radiated Emission 18GHz-40GHz 3.88dB (1) AC Power Line Conducted Emission 0.15MHz ~ 30MHz 1.20dB (1) Note (1): The measurement uncertainty is for coverage factor of k=2 and a level of confidence of 95%. Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Page 5 of 38 Report No.: AITSZ24052403FW1 3 Test Facility The test facility is recognized, certified or accredited by the following organizations: FCC-Registration No.: 251906 Designation Number: CN1376 Guangdong Asia Hongke Test Technology Limited has been registered and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files. IC --Registration No.: 31737 CAB identifier: CN0165 The 3m Semi-anechoic chamber of Guangdong Asia Hongke Test Technology Limited has been registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 31737 A2LA-Lab Cert. No.: 7133.01 Guangdong Asia Hongke Test Technology Limited has been accredited by A2LA for technical competence in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025: 2017 General Requirements for the Competence of Testing and Calibration Laboratories and any additional program requirements in the identified field of testing. 3.1 Deviation from standard None 3.2 Abnormalities from standard conditions None 3.3 Test Location Guangdong Asia Hongke Test Technology Limited Address: B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel.: +86 0755-230967639 Fax.: +86 0755-230967639 Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Page 6 of 38 Report No.: AITSZ24052403FW1 4 General Information EUT Name: Model No: Brand Name: Serial Model: Sample(s) Status: Operation frequency: Channel Number: Channel separation: Modulation Technology: Antenna Type: Antenna gain: Hardware version.: Software version.: Adapter: Model different: Note: 8K UHD MEDIA PLAYER ZD24P ZIDOO UHD8000,Z3000 PRO Engineer sample 2402MHz-2480MHz 79 Channels 1MHz GFSK, /4-DQPSK, 8DPSK stick antenna 3.18dBi N/A N/A Input: 100-240V 50/60Hz 0.8A Output: 12V2A 24W Different model names For a more detailed features description, please refer to the manufacturer's specifications or the User's Manual. Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Page 7 of 38 Report No.: AITSZ24052403FW1 4.1 Test frequencies EUT channels and frequencies list: Channel 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 Frequency (MHz) 2402 2403 2404 2405 2406 2407 2408 2409 2410 2411 2412 2413 2414 2415 2416 2417 2418 2419 2420 2421 2422 2423 2424 2425 2426 2427 2428 Channel 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 Frequency (MHz) 2429 2430 2431 2432 2433 2434 2435 2436 2437 2438 2439 2440 2441 2442 2443 2444 2445 2446 2447 2448 2449 2450 2451 2452 2453 2454 2455 Channel 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 --- Frequency (MHz) 2456 2457 2458 2459 2460 2461 2462 2463 2464 2465 2466 2467 2468 2469 2470 2471 2472 2473 2474 2475 2476 2477 2478 2479 2480 --- Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Page 8 of 38 Report No.: AITSZ24052403FW1 4.2 EUT Peripheral List No. Equipment 1 N/A Manufacturer N/A EMC Compliance N/A Model No. N/A Serial No. Power cord Signal cord N/A N/A N/A 4.3 Test Peripheral List No. Equipment 1 Notebook USB 2 Cable Mfr/Brand DELL N/A EMC Model No. Compliance VOSTRO.3 800 DELL N/A 100cm Serial No. N/A N/A Power cord Signal cord N/A N/A N/A N/A Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Page 9 of 38 Report No.: AITSZ24052403FW1 4.4 TEST METHODOLOGY The tests documented in this report were performed in accordance with ANSI C63.10-2013, FCC CFR PART 15C 15.207, 15.209, 15.247 and DA 00-705. EUT Configuration The EUT configuration for testing is installed on RF field strength measurement to meet the Commissions requirement and operating in a manner that intends to maximize its emission characteristics in a continuous normal application. EUT Exercise The EUT was operated in the normal operating mode for Hopping Numbers and Dwell Time test and a continuous transmits mode for other tests. According to its specifications, the EUT must comply with the requirements of the Section 15.203, 15.205, 15.207, 15.209, 15.247, ANSI C63.10-2013 under the FCC Rules Part 15 Subpart C General Test Procedures Conducted Emissions The EUT is placed on the turntable, which is 0.8 m above ground plane. According to the requirements in Section 6.2.1 of ANSI C63.10-2013 Conducted emissions from the EUT measured in the frequency range between 0.15 MHz and 30MHz using Quasi-peak and average detector modes. Radiated Emissions The EUT is placed on a turn table, which is 0.8 m above ground plane. The turntable shall rotate 360 degrees to determine the position of maximum emission level. EUT is set 3m away from the receiving antenna, which varied from 1m to 4m to find out the highest emission. And also, each emission was to be maximized by changing the polarization of receiving antenna both horizontal and vertical. In order to find out the maximum emissions, exploratory radiated emission measurements were made according to the requirements in Section 6.3 of ANSI C63.10-2013. Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Page 10 of 38 Report No.: AITSZ24052403FW1 4.5 Description of Test Modes The EUT has been tested under operating condition. AC main conducted emission pre-test voltage at both AC 120V/60Hz and AC 240V/50Hz, recorded worst case; AC main conducted emission pre-test at charge from power adapter modes, recorded worst case; Worst-case mode and channel used for 150 KHz-30 MHz power line conducted emissions was the mode and channel with the highest output power that was determined to be TX (1Mbps). Worst-case mode and channel used for 9 KHz-1000 MHz radiated emissions was the mode and channel with the highest output power, that was determined to be TX(1Mbps-Low Channel). This test was performed with EUT in X, Y, Z position and the worst case was found when EUT in X position. In section 15.31(m), regards to the operating frequency range over 10 MHz, the Lowest frequency, the middle frequency, and the highest frequency of channel were selected to perform the test, and the selected channel see below: Transmitting mode Keep the EUT in continuously transmitting mode. Test software: *#*#9646633#*#* Frequency Parameters(1Mbps) Parameters(2Mbps) Parameters(3Mbps) 2402 MHz Default Default Default 2441 MHz Default Default Default 2480 MHz Default Default Default Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Page 11 of 38 Report No.: AITSZ24052403FW1 5 Equipment Used during Test No Test Equipment 1 Spectrum Analyzer 2 Spectrum Analyzer Manufacturer R&S Keysight Model No FSV40 N9020A Serial No 101470 MY51280643 Cal. Date 2023.09.08 2023.09.08 Cal. Due Date 2024.09.07 2024.09.07 3 EMI Measuring Receiver R&S ESR 101660 2023.09.08 2024.09.07 4 Low Noise Pre-Amplifier HP 5 Low Noise Pre-Amplifier Tsj 6 Passive Loop ETS TRILOG Super Broadband 7 SCHWARZBECK test Antenna 8 Broadband Horn Antenna SCHWARZBECK SHF-EHF Horn Antenna 9 SCHWARZBECK 15-40GHz 10 EMI Measuring Receiver R&S 11 LISN SCHWARZBECK 12 Pulse Limiter R&S HP8447E MLA-0120-A02- 34 6512 VULB9160 1937A01855 2648A04738 00165355 9160-3206 BBHA9120D 452 BBHA9170 BBHA9170367d ESR NNLK 8129 ESH3-Z2 101160 8130179 102789 2023.09.08 2023.09.08 2022.09.04 2021.08.29 2021.08.29 2021.08.29 2023.09.13 2023.10.29 2023.09.13 2024.09.07 2024.09.07 2024.09.03 2024.08.28 2024.08.28 2024.08.28 2024.09.12 2024.10.28 2024.09.12 13 Pro.Temp&Humi.chamber MENTEK MHP-150-1C MAA08112501 2023.09.08 2024.09.07 14 RF Automatic Test system MW MW100-RFCB 21033016 2023.09.08 2024.09.07 15 Signal Generator Wideband Radio 16 communication tester 17 RF Automatic Test system Agilent R&S MW N5182A MY50143009 2023.09.08 2024.09.07 CMW500 1201.0002K50 2023.09.08 2024.09.07 MW100-RFCB 21033016 2023.09.08 2024.09.07 18 DC power supply ZHAOXIN RXN-305D-2 28070002559 N/A N/A 19 RE Software EZ EZ-EMC_RE Ver.AIT-03A N/A N/A 20 CE Software EZ EZ-EMC_CE Ver.AIT-03A N/A N/A 21 RF Software MW MTS 8310 2.0.0.0 N/A N/A temporary antenna 22 connector(Note) NTS R001 N/A N/A N/A Note: The temporary antenna connector is soldered on the PCB board in order to perform conducted tests and this temporary antenna connector is listed in the equipment list. Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Page 12 of 38 Report No.: AITSZ24052403FW1 6 Test results and Measurement Data 6.1 Antenna requirement 6.1.1 Standard requirement: An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this Section. The manufacturer may design the unit so that a broken antenna can be re-placed by the user, but the use of a standard antenna jack or electrical connector is prohibited. This requirement does not apply to carrier current devices or to devices operated under the provisions of Sections 15.211, 15.213, 15.217, 15.219, or 15.221. Further, this requirement does not apply to intentional radiators that must be professionally installed, such as perimeter protection systems and some field disturbance sensors, or to other intentional radiators which, in accordance with Section 15.31(d), must be measured at the installation site. However, the installer shall be responsible for ensuring that the proper antenna is employed so that the limits in this Part are not exceeded. And according to §15.247(4)(1), system operating in the 2400-2483.5MHz bands that are used exclusively for fixed, point-to-point operations may employ transmitting antennas with directional gain greater than 6dBi provided the maximum peak output power of the intentional radiator is reduced by 1 dB for every 3 dB that the directional gain of the antenna exceeds 6dBi. 6.1.2 EUT Antenna: The antenna is stick antenna, the best case gain of the antenna is 3.18dBi reference to the Internal photos for details Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Page 13 of 38 6.2 Peak Power Measurement Report No.: AITSZ24052403FW1 6.2.1 Standard requirement: According to §15.247(b)(1), For frequency hopping systems operating in the 24002483.5 MHz band employing at least 75 non-overlapping hopping channels, and all frequency hopping systems in the 57255850 MHz band: 1 watt. For all other frequency hopping systems in the 24002483.5 MHz band: 0.125 watts. 6.2.2 Measuring Instruments: Please refer to equipment's list in this report. 6.2.3 Test Procedures: The transmitter output (antenna port) was connected to the spectrum analyzer. According to ANSI C63.10:2013 Output power test procedure for frequency-hopping spread-spectrum (FHSS) devices; this is an RF-conducted test to evaluate maximum peak output power. Use a direct connection between the antenna port of the unlicensed wireless device and the spectrum analyzer, through suitable attenuation. The hopping shall be disabled for this test: a) Use the following spectrum analyzer settings: 1) Span: Approximately five times the 20 dB bandwidth, centered on a hopping channel. 2) RBW > 20 dB bandwidth of the emission being measured. 3) VBW RBW. 4) Sweep: Auto. 5) Detector function: Peak. 6) Trace: Max hold. b) Allow trace to stabilize. c) Use the marker-to-peak function to set the marker to the peak of the emission. d) The indicated level is the peak output power, after any corrections for external attenuators and cables. 6.2.4 Test Setup Layout 6.2.5 EUT Operation during Test The EUT was programmed to be in continuously transmitting mode. Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. 6.2.6 Test result Please refer to Appendix A Page 14 of 38 Report No.: AITSZ24052403FW1 Remark: 1. Test results including cable loss; 2. Measured output power at difference Packet Type for each mode and recorded worst case for each mode. Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Page 15 of 38 6.3 Frequency Separation and 20 dB Bandwidth Report No.: AITSZ24052403FW1 6.3.1 Standard requirement: According to §15.247(a) (1), Frequency hopping systems shall have hopping channel carrier frequencies separated by a minimum of 25 kHz or the 20 dB bandwidth of the hopping channel, whichever is greater. Alternatively, frequency hopping systems operating in the 2400-2483.5 MHz band may have hopping channel carrier frequencies that are separated by 25 kHz or two-thirds of the 20 dB bandwidth of the hopping channel, whichever is greater, provided the systems operate with an output power no greater than 125 mW. 6.3.2 Measuring Instruments: Please refer to equipment's list in this report. 6.3.3 Test Procedures Frequency separation test procedure 1). Place the EUT on the table and set it in transmitting mode. 2). Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port to the Spectrum Analyzer. 3). Set center frequency of Spectrum Analyzer = middle of hopping channel. 4). Set the Spectrum Analyzer as RBW = 100 kHz, VBW =300 kHz, Span = wide enough to capture the peaks of two adjacent channels, Sweep = auto. 5). Max hold, mark 2 peaks of hopping channel and record the 2 peaks frequency. 20dB bandwidth test procedure 1). Span = approximately 2 to 3 times the 20 dB bandwidth, centered on a hopping channel. 2). RBW 1% of the 20 dB bandwidth, VBW RBW. 3). Detector function = peak. 4). Trace = max hold. 6.3.4 Test Setup Layout Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Page 16 of 38 Report No.: AITSZ24052403FW1 6.3.5 EUT Operation during Test The EUT was programmed to be in continuously transmitting mode. 6.3.6 Test result PASS Please refer to Appendix A for 20 dB bandwidth Please refer to Appendix A for Frequency separation Remark: 1). Test results including cable loss; 2). Measured at difference Packet Type for each mode and recorded worst case for each mode. Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Page 17 of 38 6.4 Number of Hopping Frequency Report No.: AITSZ24052403FW1 6.4.1 Standard requirement: According to §15.247(a)(1)(ii), Frequency hopping systems operating in the band 2400-2483.5 MHz shall use at least 15 hopping channels. 6.4.2 Measuring Instruments and Setting: Please refer to equipment's list in this report. 6.4.3 Test Procedures 1). Place the EUT on the table and set it in transmitting mode. 2). Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port to the Spectrum Analyzer. 3). Set Spectrum Analyzer Start=2400MHz, Stop = 2483.5MHz, Sweep = auto. 4). Set the Spectrum Analyzer as RBW/VBW=100KHz/300KHz. 5). Max hold, view and count how many channel in the band. 6.4.4 Test Setup Layout 6.4.5 EUT Operation during Test The EUT was programmed to be in continuously transmitting mode. 6.4.6 Test result PASS Please refer to Appendix A Remark: 1). Test results including cable loss; 2). Measured at difference Packet Type for each mode and recorded worst case for each mode. Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Page 18 of 38 6.5 Time of Occupancy (Dwell Time) Report No.: AITSZ24052403FW1 6.5.1 Standard requirement: According to §15.247(a)(1)(iii), Frequency hopping systems operating in the 2400MHz- 2483.5 MHz bands. The average time of occupancy on any channels shall not greater than 0.4 s within a period 0.4 s multiplied by the number of hopping channels employed. 6.5.2 Measuring Instruments and Setting: Please refer to equipment's list in this report. The following table is the setting of Spectrum Analyzer. 6.5.3 Test Procedures 1). Place the EUT on the table and set it in transmitting mode. 2). Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port to the Spectrum Analyzer. 3). Set center frequency of Spectrum Analyzer = operating frequency. 4). Set the Spectrum Analyzer as RBW=1MHz, VBW=3MHz, Span = 0Hz, Sweep = auto. 5). Repeat above procedures until all frequency measured was complete. 6.5.4 Test Setup Layout 6.5.5 EUT Operation during Test The EUT was programmed to be in continuously transmitting mode. 6.5.6 Test result PASS Please refer to Appendix A Remark: 1). Test results including cable loss; 2). Measured at difference Packet Type for each mode and recorded worst case for each mode. 3). The Dwell Time=Burst Width*Total Hops. The detailed calculations are showed as follows: The duration for dwell time calculation: 0.4[s]*hopping number=0.4[s]*79[ch]=31.6[s*ch]; The burst width [ms/hop/ch], which is directly measured, refers to the duration on one channel hop. The hops per second for all channels: The selected EUT Conf uses a slot type of 5-Tx&1-Rx and a Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Page 19 of 38 Report No.: AITSZ24052403FW1 hopping rate of 1600 [ch*hop/s] for all channels. So the final hopping rate for all channels is 1600/6=266.67 [ch*hop/s] The hops per second on one channel: 266.67 [ch*hops/s]/79 [ch]=3.38 [hop/s]; The total hops for all channels within the dwell time calculation duration: 3.38 [hop/s]*31.6[s*ch]=106.67 [hop*ch]; The dwell time for all channels hopping: 106.67 [hop*ch]*Burst Width [ms/hop/ch]. Dwell Time Calculate formula: DH1: Dwell time=Pulse time (ms) × (1600 ÷2 ÷79) ×31.6 Second DH3: Dwell time=Pulse time (ms) × (1600 ÷4 ÷79) ×31.6 Second DH5: Dwell time=Pulse Time (ms) × (1600 ÷6 ÷79) ×31.6 Second 4). Measured at low, middle and high channel, recorded the worst case. 5). Only Recorded DH5. Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Page 20 of 38 Report No.: AITSZ24052403FW1 6.6 Conducted Spurious Emissions and Band Edges Test 6.6.1 Standard requirement: In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement. Attenuation below the general limits specified in Section 15.209(a) is not required. 6.6.2 Measuring Instruments and Setting: Please refer to equipment list in this report. The following table is the setting of the spectrum analyzer. Spectrum Parameter Detector Attenuation RB / VB (Emission in restricted band) RB / VB (Emission in non-restricted band) Setting Peak Auto 100KHz/300KHz 100KHz/300KHz 6.6.3 Test Procedures Conducted RF measurements of the transmitter output were made to confirm that the EUT antenna port conducted emissions meet the specified limit and to identify any spurious signals that require further investigation or measurements on the radiated emissions site. The transmitter output is connected to the spectrum analyzer. The resolution bandwidth is set to 100 KHz. The video bandwidth is set to 300 KHz. Measurements are made over the 9kHz to 25GHz range with the transmitter set to the lowest, middle, and highest channels. 6.6.4 Test Setup Layout 6.6.5 EUT Operation during Test The EUT was programmed to be in continuously transmitting mode. 6.6.6 Test result PASS Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Page 21 of 38 Report No.: AITSZ24052403FW1 No non-compliance noted. Only record the worst test result in this report. The test data refer to the following page. PASS Please refer to Appendix A for conducted spurious emission. Please refer to Appendix A for conducted band edge. Remark: 1. Test results including cable loss; 2. Measured at difference Packet Type for each mode and recorded worst case for each mode. Worst case data at DH5 for GFSK, 2DH5 for /4-DQPSK and 3DH5 for 8DPSK modulation type; 3. "---"means that the fundamental frequency not for 15.209 limits requirement. Not recorded emission from 9 KHz to 30 MHz as emission level at least 20dBc lower than emission limit. Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Page 22 of 38 Report No.: AITSZ24052403FW1 6.7 Radiated Emissions and Radiation Restricted band Measurement 6.7.1 Standard requirement: According to §15.247 (d): 20dBc in any 100 kHz bandwidth outside the operating frequency band. In case the emission fall within the restricted band specified on 15.205(a), then the 15.209(a) limit in the table below has to be followed. Frequencies (MHz) 0.009~0.490 0.490~1.705 1.705~30.0 30~88 88~216 216~960 Above 960 Field Strength (microvolts/meter) 2400/F(KHz) 24000/F(KHz) 30 100 150 200 500 6.7.2 Measuring Instruments and Setting: Measurement Distance (meters) 300 30 30 3 3 3 3 Please refer to equipment list in this report. The following table is the setting of spectrum analyzer and receiver. Spectrum Parameter Attenuation Start Frequency Stop Frequency RB / VB (Emission in restricted band) RB / VB (Emission in non-restricted band) Setting Auto 1000 MHz 10th carrier harmonic 1MHz / 1MHz for Peak, 1 MHz / 1/B kHz for Average 1MHz / 1MHz for Peak, 1 MHz / 1/B kHz for Average Receiver Parameter Attenuation Start ~ Stop Frequency Start ~ Stop Frequency Start ~ Stop Frequency Setting Auto 9kHz~150kHz / RB/VB 200Hz/1KHz for QP/AVG 150kHz~30MHz / RB/VB 9kHz/30KHz for QP/AVG 30MHz~1000MHz / RB/VB 120kHz/1MHz for QP Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Page 23 of 38 Report No.: AITSZ24052403FW1 6.7.3 Test Procedures 1) Sequence of testing 9 kHz to 30 MHz Setup: --- The equipment was set up to simulate a typical usage like described in the user manual or described by manufacturer. --- If the EUT is a tabletop system, a rotatable table with 0.8 m height is used. --- If the EUT is a floor standing device, it is placed on the ground. --- Auxiliary equipment and cables were positioned to simulate normal operation conditions. --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable. --- The measurement distance is 3 meter. --- The EUT was set into operation. Premeasurement: --- The turntable rotates from 0°to 315°using 45°steps. --- The antenna height is 1.5 meter. --- At each turntable position the analyzer sweeps with peak detection to find the maximum of all emissions Final measurement: --- Identified emissions during the premeasurement the software maximizes by rotating the turntable position (0°to 360°) and by rotating the elevation axes (0°to 360°). --- The final measurement will be done in the position (turntable and elevation) causing the highest emissions with QPK detector. --- The final levels, frequency, measuring time, bandwidth, turntable position, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of the premeasurement and the limit will be stored. Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Page 24 of 38 Report No.: AITSZ24052403FW1 2) Sequence of testing 30 MHz to 1 GHz Setup: --- The equipment was set up to simulate a typical usage like described in the user manual or described by manufacturer. --- If the EUT is a tabletop system, a table with 0.8 m height is used, which is placed on the ground plane. --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both. --- Auxiliary equipment and cables were positioned to simulate normal operation conditions --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable. --- The measurement distance is 3 meter. --- The EUT was set into operation. Premeasurement: --- The turntable rotates from 0°to 315°using 45°steps. --- The antenna is polarized vertical and horizontal. --- The antenna height changes from 1 to 3 meter. --- At each turntable position, antenna polarization and height the analyzer sweeps three times in peak to find the maximum of all emissions. Final measurement: --- The final measurement will be performed with minimum the six highest peaks. --- According to the maximum antenna and turntable positions of premeasurement the software maximize the peaks by changing turntable position (±45°) and antenna movement between 1 and 4 meter. --- The final measurement will be done with QP detector with an EMI receiver. --- The final levels, frequency, measuring time, bandwidth, antenna height, antenna polarization, turntable angle, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of the premeasurement with marked maximum final measurements and the limit will be stored. Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Page 25 of 38 Report No.: AITSZ24052403FW1 3) Sequence of testing 1 GHz to 18 GHz Setup: --- The equipment was set up to simulate a typical usage like described in the user manual or described by manufacturer. --- If the EUT is a tabletop system, a rotatable table with 1.5 m height is used. --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both. --- Auxiliary equipment and cables were positioned to simulate normal operation conditions --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable. --- The measurement distance is 3 meter. --- The EUT was set into operation. Premeasurement: --- The turntable rotates from 0°to 315°using 45°steps. --- The antenna is polarized vertical and horizontal. --- The antenna height scan range is 1 meter to 2.5 meter. --- At each turntable position and antenna polarization the analyzer sweeps with peak detection to find the maximum of all emissions. Final measurement: --- The final measurement will be performed with minimum the six highest peaks. --- According to the maximum antenna and turntable positions of premeasurement the software maximize the peaks by changing turntable position (±45°) and antenna movement between 1 and 4 meter. This procedure is repeated for both antenna polarizations. --- The final measurement will be done in the position (turntable, EUT-table and antenna polarization) causing the highest emissions with Peak and Average detector. --- The final levels, frequency, measuring time, bandwidth, turntable position, EUT-table position, antenna polarization, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of the premeasurement with marked maximum final measurements and the limit will be stored. Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Page 26 of 38 Report No.: AITSZ24052403FW1 4) Sequence of testing above 18 GHz Setup: --- The equipment was set up to simulate a typical usage like described in the user manual or described by manufacturer. --- If the EUT is a tabletop system, a rotatable table with 1.5 m height is used. --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both. --- Auxiliary equipment and cables were positioned to simulate normal operation conditions --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable. --- The measurement distance is 1 meter. --- The EUT was set into operation. Premeasurement: --- The antenna is moved spherical over the EUT in different polarisations of the antenna. Final measurement: --- The final measurement will be performed at the position and antenna orientation for all detected emissions that were found during the premeasurements with Peak and Average detector. --- The final levels, frequency, measuring time, bandwidth, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of the premeasurement and the limit will be stored. 6.7.4 Test Setup Layout Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Page 27 of 38 Report No.: AITSZ24052403FW1 Above 18 GHz shall be extrapolated to the specified distance using an extrapolation factor of 20 dB/decade form 3m to 1m. Distance extrapolation factor = 20 log (specific distance [3m] / test distance [1m]) (dB); Limit line = specific limits (dBuV) + distance extrapolation factor [6 dB]. 6.7.5 EUT Operation during Test The EUT was programmed to be in continuously transmitting mode. 6.7.6 Test result . Temperature 26 Humidity 54% Configurations BT Remarks: 1. Only the worst case Main Antenna test data. 2. Pre-scan all kind of the place mode (X-axis, Y-axis, Z-axis), and found the Y-axis which it is worse case. Results of Radiated Emissions (9 KHz~30MHz) Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Freq. (MHz) - Page 28 of 38 Level (dBuV) - Over Limit (dB) - Report No.: AITSZ24052403FW1 Over Limit (dBuV) - Remark See Note Note: The emission from 9 kHz to 30MHz was pre-tested and found the result was 20dB lower than the limit, and the permissible value has no need to be reported. Distance extrapolation factor = 40 log (specific distance / test distance) (dB); Limit line = specific limits (dBuV) + distance extrapolation factor. Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Page 29 of 38 Report No.: AITSZ24052403FW1 Results of Radiated Emissions (30MHz~1GHz) Pre-scan all test modes, found worst case at 8DPSK (MCH), and so only show the test result of 8DPSK (MCH). Model name: ZD24P Test Date : 2024-05-27 Polarization : Vertical Test Result: Pass Fail Remark: Emission Level = Reading + Factor; Factor = Antenna Factor + Cable Loss Pre-amplifier; Margin= Emission Level - Limit. Frequency Reading Factor Level Limit Margin No. Det. (MHz) (dBuV) (dB/m) (dBuV/m) (dBuV/m) (dB) 1 31.1688 35.71 -17.48 18.23 40.00 -21.77 QP 2 68.2231 36.40 -18.63 17.77 40.00 -22.23 QP 3 178.0078 37.46 -18.02 19.44 43.50 -24.06 QP 4 264.3745 38.36 -18.05 20.31 46.00 -25.69 QP 5 608.6398 35.20 -9.53 25.67 46.00 -20.33 QP 6 * 940.1504 36.47 -3.77 32.70 46.00 -13.30 QP Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Model name: Polarization : ZD24P Horizontal Page 30 of 38 Report No.: AITSZ24052403FW1 Test Date : Test Result: 2024-05-27 Pass Fail Remark: Emission Level = Reading + Factor; Factor = Antenna Factor + Cable Loss Pre-amplifier; Margin= Emission Level - Limit. Frequency Reading Factor Level Limit Margin No. Det. (MHz) (dBuV) (dB/m) (dBuV/m) (dBuV/m) (dB) 1 39.4925 33.99 -16.52 17.47 40.00 -22.53 QP 2 153.3616 33.60 -16.52 17.08 43.50 -26.42 QP 3 262.8955 35.36 -18.09 17.27 46.00 -28.73 QP 4 386.2273 33.10 -14.86 18.24 46.00 -27.76 QP 5 647.1586 35.88 -8.91 26.97 46.00 -19.03 QP 6 * 953.7645 35.23 -3.50 31.73 46.00 -14.27 QP Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Page 31 of 38 Report No.: AITSZ24052403FW1 Results for Radiated Emissions (1- 26 GHz) Test channel: Lowest channel H Frequency (MHz) 4804 4804 7206 7206 V Frequency (MHz) 4804 4804 7206 7206 Meter Reading (dBV) 47.58 36.19 44.10 31.05 Meter Reading (dBV) 46.60 35.47 40.60 31.35 Factor (dB/m) 5.06 5.06 7.03 7.03 Factor (dB/m) 5.06 5.06 7.03 7.03 Emission Level (dBV/m) 52.64 41.25 51.13 38.08 Limits (dBV/m) 74 54 74 54 Emission Level (dBV/m) 51.66 40.53 47.63 38.38 Limits (dBV/m) 74 54 74 54 Margin (dB) -21.36 -12.75 -22.87 -15.92 Detector Type PEAK AVG PEAK AVG Margin (dB) -22.34 -13.47 -26.37 -15.62 Detector Type PEAK AVG PEAK AVG Test channel: Middle channel H Frequency (MHz) 4882 4882 7323 7323 V Frequency (MHz) 4882 4882 7323 7323 Meter Reading (dBV) 47.83 37.40 41.66 32.22 Meter Reading (dBV) 46.51 34.45 40.71 31.00 Factor (dB/m) 5.14 5.14 7.52 7.52 Factor (dB) 5.14 5.14 7.52 7.52 Emission Level (dBV/m) 52.97 42.54 49.18 39.74 Limits (dBV/m) 74 54 74 54 Emission Level (dBV/m) 51.65 39.59 48.23 38.52 Limits (dBV/m) 74 54 74 54 Margin (dB) -21.03 -11.46 -24.82 -14.26 Detector Type PEAK AVG PEAK AVG Margin (dB) -22.35 -14.41 -25.77 -15.48 Detector Type PEAK AVG PEAK AVG Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Page 32 of 38 Report No.: AITSZ24052403FW1 Test channel: Highest channel H Frequency (MHz) 4960 4960 7440 7440 V Frequency (MHz) 4960 4960 7440 7440 Meter Reading (dBV) 47.65 35.69 39.89 30.39 Meter Reading (dBV) 46.37 35.99 41.97 31.01 Factor (dB/m) 5.22 5.22 8.06 8.06 Factor (dB) 5.22 5.22 8.06 8.06 Emission Level (dBV/m) 52.87 40.91 47.95 38.45 Limits (dBV/m) 74 54 74 54 Emission Level (dBV/m) 51.59 41.21 50.03 39.07 Limits (dBV/m) 74 54 74 54 Margin (dB) -21.13 -13.09 -26.05 -15.55 Detector Type PEAK AVG PEAK AVG Margin (dB) -22.41 -12.79 -23.97 -14.93 Detector Type PEAK AVG PEAK AVG Remarks: 1). Measuring frequencies from 9 KHz - 10th harmonic or 26.5GHz (which is less), No emission found between lowest internal used/generated frequency to 30MHz. 2). Radiated emissions measured in frequency range from 9 KHz~10th harmonic or 26.5GHz (which is less) were made with an instrument using Peak detector mode. 3). Data of measurement within this frequency range shown "---" in the table above means the reading of emissions are attenuated more than 20dB below the permissible limits or the field strength is too small to be measured. 4). Margin= Emission Level Limit 5). Emission Level = Reading + Factor 6). Factor = Antenna Factor + Cable Loss Pre-amplifier 7). All the modes have been tested and the only shows the worst case 8DPSK mode Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Radiation Restricted band Frequency No. (MHz) 1 2386.02 2 2390 3 2400 Page 33 of 38 Reading (dBuV) 41.31 40.82 40.06 Horizontal-L Factor Level (dB/m) (dBuV/m) -5.66 35.65 -5.72 35.1 -5.61 34.45 Report No.: AITSZ24052403FW1 Limit (dBuV/m) 74 74 74 Margin (dB) -38.35 -38.9 -39.55 Det. peak peak peak Vertical-L Frequency Reading Factor Level Limit Margin No. (MHz) (dBuV) (dB/m) (dBuV/m) (dBuV/m) (dB) 1 2385.23 42.77 -5.95 36.82 74 -37.18 2 2390 40.92 -5.94 34.98 74 -39.02 3 2400 39.44 -5.65 33.79 74 -40.21 Det. peak peak peak Horizontal-H Frequency Reading Factor Level Limit Margin No. (MHz) (dBuV) (dB/m) (dBuV/m) (dBuV/m) (dB) 1 2483.5 36.33 -5.05 31.28 74 -42.72 2 2485.5 38.39 -5.07 33.32 74 -40.68 Det. peak peak Vertical-H Frequency Reading Factor Level Limit Margin No. (MHz) (dBuV) (dB/m) (dBuV/m) (dBuV/m) (dB) 1 2483.5 36.09 -4.73 31.36 74 -42.64 2 2485.22 37.8 -5.05 32.75 74 -41.25 Det. peak peak Remarks: 1). Margin= Emission Level Limit 2). Emission Level = Reading + Factor 3). Factor = Antenna Factor + Cable Loss Pre-amplifie 4). All the modes have been tested and the only shows the worst case 8DPSK mode. 5).The PEAK value is less than the AVG limit, the AVG result no need be show in this report. Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. 6.8 Conducted Emissions Page 34 of 38 Report No.: AITSZ24052403FW1 6.8.1 Standard requirement: According to §15.207 (a): For an intentional radiator which is designed to be connected to the public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any frequency or frequencies within the band 150 kHz to 30 MHz shall not exceed 250 microvolts (The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50 MHz). The limits at specific frequency range is listed as follows: Frequency Range (MHz) 0.15 to 0.50 0.50 to 5 5 to 30 Limits (dBV) Quasi-peak 66 to 56 56 60 Average 56 to 46 46 50 * Decreasing linearly with the logarithm of the frequency 6.8.2 Test Procedures The transmitter output is connected to EMI receiver. The resolution bandwidth is set to 9 kHz. The video bandwidth is set to 30 kHz, Sweep time=Auto The spectrum from 150 kHz to 30MHz is investigated with the transmitter set to the lowest, middle, and highest channels. 6.8.3 Test Setup Layout 6.8.4 EUT Operation during Test The EUT was programmed to be in continuously transmitting mode. 6.8.5 Test result PASS The test data please refer to following page. Temperature 26 Humidity 54% Configurations BT Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Page 35 of 38 Report No.: AITSZ24052403FW1 Measurement data: Pre-scan all test modes, found worst case at 8DPSK 2441MHz, and so only show the test result of 8DPSK 2441MHz Model name: ZD24P Test Date : 2024-05-27 ATM Pressure: 101 kPa Test Result: Pass Fail Phase : Line Remark: Correct Factor = Insertion loss of LISN + Cable loss + Insertion loss of Pulse Limiter; Measurement Result = Reading Level +Correct Factor; Margin = Measurement Result- Limit; No. Frequency Reading Correct Result Limit Margin (MHz) (dBuV) (dB) (dBuV) (dBuV) (dB) 1 0.1635 24.43 10.67 35.10 55.28 -20.18 2 0.1770 44.24 10.68 54.92 64.63 -9.71 3 0.2040 22.32 10.70 33.02 53.45 -20.43 4 0.2310 39.65 10.70 50.35 62.41 -12.06 5 0.2310 22.86 10.70 33.56 52.41 -18.85 6 0.2760 41.52 10.70 52.22 60.94 -8.72 7 0.2760 17.44 10.70 28.14 50.94 -22.80 8 0.3209 34.36 10.70 45.06 59.68 -14.62 9 0.4110 31.15 10.69 41.84 57.63 -15.79 10 0.4110 20.43 10.69 31.12 47.63 -16.51 11 0.4830 29.27 10.69 39.96 56.29 -16.33 12 0.4830 18.58 10.69 29.27 46.29 -17.02 Remark AVG QP AVG QP AVG QP AVG QP QP AVG QP AVG Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Model name: ATM Pressure: Phase : ZD24P 101 kPa Neutral Page 36 of 38 Report No.: AITSZ24052403FW1 Test Date : Test Result: 2024-05-27 Pass Fail Remark: Correct Factor = Insertion loss of LISN + Cable loss + Insertion loss of Pulse Limiter; Measurement Result = Reading Level +Correct Factor; Margin = Measurement Result- Limit; No. Frequency Reading Correct Result Limit Margin Remark (MHz) (dBuV) (dB) (dBuV) (dBuV) (dB) 1 0.1632 22.63 10.67 33.30 55.30 -22.00 AVG 2 0.1635 45.04 10.67 55.71 65.28 -9.57 QP 3 0.1844 21.54 10.69 32.23 54.29 -22.06 AVG 4 0.1995 40.13 10.69 50.82 63.63 -12.81 QP 5 0.1995 21.49 10.69 32.18 53.63 -21.45 AVG 6 0.2220 38.01 10.69 48.70 62.74 -14.04 QP 7 0.2220 20.56 10.69 31.25 52.74 -21.49 AVG 8 0.2805 35.34 10.69 46.03 60.80 -14.77 QP 9 0.4154 20.51 10.69 31.20 47.54 -16.34 AVG 10 0.4830 23.48 10.69 34.17 46.29 -12.12 AVG 11 0.4874 33.33 10.69 44.02 56.21 -12.19 QP 12 1.0363 25.40 10.64 36.04 56.00 -19.96 QP Notes: 1. An initial pre-scan was performed on the line and neutral lines with peak detector. 2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission. 3. If the average limit is met when using a quasi-peak detector receiver, the EUT shall be deemed to meet both limits and measurement with the average detector receiver is unnecessary. Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Page 37 of 38 6.9 Pseudorandom frequency hopping sequence Report No.: AITSZ24052403FW1 For 47 CFR Part 15C sections §15.247(a)(1) or RSS-247§5.1 requirement: Frequency hopping systems shall have hopping channel carrier frequencies separated by a minimum of 25 kHz or the 20 dB bandwidth of the hop-ping channel, whichever is greater. Alternatively, frequency hopping systems operating in the 24002483.5 MHz band may have hopping channel carrier frequencies that are separated by 25 kHz or two-thirds of the 20 dB bandwidth of the hopping channel, whichever is greater, provided the systems operate with an output power no greater than 125 mW. The system shall hop to channel frequencies that are selected at the system hopping rate from a pseudo randomly ordered list of hopping frequencies. Each frequency must be used equally on the average by each transmitter. The system receivers shall have input bandwidths that match the hop-ping channel bandwidths of their corresponding transmitters and shall shift frequencies in synchronization with the transmitted signals. EUT Pseudorandom Frequency Hopping Sequence Requirement: The pseudorandom frequency hopping sequence may be generated in a nice-stage shift register whose 5th first stage. The sequence begins with the first one of 9 consecutive ones, for example: the shift register is initialized with nine ones. Number of shift register stages:9 Length of pseudo-random sequence:29-1=511 bits Longest sequence of zeros:8(non-inverted signal) An example of pseudorandom frequency hopping sequence as follows: Each frequency used equally one the average by each transmitter. The system receiver have input bandwidths that match the hopping channel bandwidths of their corresponding transmitter and shift frequencies in synchronization with the transmitted signals. . Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Page 38 of 38 Report No.: AITSZ24052403FW1 7 Test Setup Photographs of EUT Please refer to separated files for Test Setup Photos of the EUT. 8 External Photographs of EUT Please refer to separated files for External Photos of the EUT. 9 Internal Photographs of EUT Please refer to separated files for Internal Photos of the EUT. ------End------ Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China.Microsoft Word 2019