Shenzhen Cudy Technology Co., Ltd. RT02 2APRGRT02 2APRGRT02 rt02
Page 1 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED FCC TEST REPORT For Shenzhen Cudy Technology Co., Ltd. Wi-Fi Router Test Model: WR3000 Additional Model No.: Please Refer to Page 6 Prepared for Address : Shenzhen Cudy Technology Co., Ltd. Room A606, Gaoxinqi Industrial Park, Liuxianyi Road, Baoan District, : Shenzhen, China Prepared by Address Tel Fax Web Mail : Shenzhen LCS Compliance Testing Laboratory Ltd. 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, : Shajing Street, Baoan District, Shenzhen, 518000, China : (+86)755-82591330 : (+86)755-82591332 : www.LCS-cert.com : webmaster@LCS-cert.com Date of receipt of test sample Number of tested samples Sample No. Serial number Date of Test Date of Report : March 17, 2023 : 2 : A031723030-1, A031723030-2 : Prototype : March 17, 2023 ~ April 10, 2023 : April 10, 2023 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 2 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED FCC TEST REPORT FCC CFR 47 PART 15 E (15.407) Report Reference No. ................. : LCSA031723030ED Date of Issue ................................. : April 10, 2023 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Address ......................................... : Shajing Street, Baoan District, Shenzhen, 518000, China Full application of Harmonised standards Testing Location/ Procedure .......... : Partial application of Harmonised standards Other standard testing method Applicant's Name.......................... : Shenzhen Cudy Technology Co., Ltd. Address ......................................... : Room A606, Gaoxinqi Industrial Park, Liuxianyi Road, Baoan District, Shenzhen, China Test Specification Standard........................................ : FCC CFR 47 PART 15E (15.407) Test Report Form No. ................... : LCSEMC-1.0 TRF Originator ............................... : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. EUT Description............................ : Wi-Fi Router Trade Mark .................................... : Cudy Test Model..................................... : WR3000 Ratings .......................................... : Input: 12V 1A For AC Adapter Input: 100-240V~, 50/60Hz, 0.5A MAX Adapter Output: 12.0V 1.0A, 12.0W Result .......................................... : Positive Compiled by: Supervised by: Approved by: Li Huan/Administrator Cary Luo/ Technique principal Gavin Liang/ Manager Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 3 of 227 FCC ID: 2APRGRT02 FCC -- TEST REPORT Report No.: LCSA031723030ED Test Report No. : LCSA031723030ED April 10, 2023 Date of issue EUT......................................... : Wi-Fi Router Test Model............................... : WR3000 Applicant............................... Address.................................. Telephone............................... Fax.......................................... : Shenzhen Cudy Technology Co., Ltd. Room A606, Gaoxinqi Industrial Park, Liuxianyi Road, Baoan : District, Shenzhen, China : / : / Manufacturer........................ Address................................... Telephone............................... Fax.......................................... : Shenzhen Cudy Technology Co., Ltd. Room A606, Gaoxinqi Industrial Park, Liuxianyi Road, Baoan : District, Shenzhen, China : / : / Factory................................... Address................................... Telephone............................... Fax.......................................... : Shenzhen Cudy Technology Co., Ltd. Room A606, Gaoxinqi Industrial Park, Liuxianyi Road, Baoan : District, Shenzhen, China : / : / Test Result: Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 4 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Report Version 000 Revision History Issue Date April 10, 2023 Revision Content Initial Issue Revised By --- Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 5 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED TABLE OF CONTENTS 1. GENERAL INFORMATION............................................................................................................................................ 6 1.1. DESCRIPTION OF DEVICE (EUT) ................................................................................................................................... 6 1.2. HOST SYSTEM CONFIGURATION LIST AND DETAILS ..................................................................................................... 8 1.3. EXTERNAL I/O CABLE .................................................................................................................................................... 8 1.4. DESCRIPTION OF TEST FACILITY ................................................................................................................................... 8 1.5. STATEMENT OF THE MEASUREMENT UNCERTAINTY ..................................................................................................... 8 1.6. MEASUREMENT UNCERTAINTY ...................................................................................................................................... 8 1.7. DESCRIPTION OF TEST MODES ..................................................................................................................................... 9 1.8. CHANNEL LIST AND FREQUENCY ................................................................................................................................. 10 1.9. CONDUTED OUTPUT POWER AND EIRP ..................................................................................................................... 11 2. TEST METHODOLOGY .................................................................................................................................................. 12 3. SYSTEM TEST CONFIGURATION............................................................................................................................... 12 3.1. EUT EXERCISE SOFTWARE......................................................................................................................................... 12 3.2. SPECIAL ACCESSORIES ............................................................................................................................................... 12 3.3. BLOCK DIAGRAM/SCHEMATICS.................................................................................................................................... 12 3.4. EQUIPMENT MODIFICATIONS ....................................................................................................................................... 12 3.5. TEST SETUP ................................................................................................................................................................. 12 4. SUMMARY OF TEST RESULTS ................................................................................................................................... 13 5. DESCRIPTION OF DYNAMIC FREQUENCY SELECTION TEST........................................................................... 14 5.1. REQUIREMENTS ............................................................................................................................................. 14 5.2. RESPONSE REQUIREMENTS ...................................................................................................... ..........15 6. DFS DETECTION THRESHOLD VALUES .................................................................................................................. 16 7. DFS TEST SIGNALS ....................................................................................................................................................... 16 8. TEST RESULT .................................................................................................................................................................. 22 9. LIST OF MEASURING EQUIPMENTS ....................................................................................................................... 225 10. TEST SETUP PHOTOGRAPHS OF EUT ................................................................................................................ 227 11. EXTERIOR PHOTOGRAPHS OF THE EUT............................................................................................................ 227 12. INTERIOR PHOTOGRAPHS OF THE EUT ............................................................................................................. 227 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 6 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED 1. GENERAL INFORMATION 1.1. Description of Device (EUT) EUT Test Model Additional Model No. Model Declaration Power Supply Hardware Version Software Version WIFI(2.4G Band) Frequency Range Channel Number Channel Spacing Modulation Type Antenna Description WIFI(5.2G Band) Frequency Range Channel Number Modulation Type Antenna Description 5.3G WLAN Frequency Range : Wi-Fi Router : WR3000 WR3000 Plus, WR1500, TR3000, M3000, RE3000, AP3000, AP3000 : Outdoor PCB board, structure and internal of these model(s) are the same, So no : additional models were tested : Input: 12V 1A For AC Adapter Input: 100-240V~, 50/60Hz, 0.5A MAX Adapter Output: 12.0V 1.0A, 12.0W : V1 : 1.15.3 : : 2412MHz~2462MHz : 11 Channels for 20MHz bandwidth (2412~2462MHz) 7 Channels for 40MHz bandwidth (2422~2452MHz) : 5MHz : IEEE 802.11b: DSSS (CCK, DQPSK, DBPSK) IEEE 802.11g: OFDM (64QAM, 16QAM, QPSK, BPSK) IEEE 802.11n: OFDM (64QAM, 16QAM, QPSK, BPSK) IEEE 802.11ax: OFDM (1024QAM, 256QAM, 64QAM, 16QAM, QPSK, BPSK) : Antenna0: External Antenna, 3.61dBi(Max.) Antenna1: External Antenna, 2.35dBi(Max.) : : 5150MHz~5250MHz : 4 channels for 20MHz bandwidth(5180MHz~5240MHz) 2 channels for 40MHz bandwidth(5190MHz~5230MHz) 1 channels for 80MHz bandwidth(5210MHz) 1 channels for 160MHz bandwidth(5250MHz) : IEEE 802.11a: OFDM (64QAM, 16QAM, QPSK, BPSK) IEEE 802.11n: OFDM (64QAM, 16QAM, QPSK, BPSK) IEEE 802.11ac: OFDM (256QAM, 64QAM, 16QAM, QPSK, BPSK) IEEE 802.11ax: OFDM (1024QAM, 256QAM, 64QAM, 16QAM, QPSK, BPSK) : Antenna0: External Antenna, 3.68dBi(Max.) Antenna1: External Antenna, 4.43dBi(Max.) Antenna2: External Antenna, 4.26dBi(Max.) : 5250-5350MHz Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 7 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Channel Number Modulation Type Antenna Description 5.5G WLAN Frequency Range Channel Number Modulation Type Antenna Description WIFI(5.8G Band) Frequency Range Channel Number Modulation Type Antenna Description : 4 Channels for 20MHz bandwidth(5260MHz-5320MHz) 2 channels for 40MHz bandwidth(5270MHz~5310MHz) 1 channels for 80MHz bandwidth(5290MHz) 1 channels for 160MHz bandwidth(5250MHz) : IEEE 802.11a: OFDM (64QAM, 16QAM, QPSK, BPSK) IEEE 802.11n: OFDM (64QAM, 16QAM, QPSK, BPSK) IEEE 802.11ac: OFDM (256QAM, 64QAM, 16QAM, QPSK, BPSK) IEEE 802.11ax: OFDM (1024QAM, 256QAM, 64QAM, 16QAM, QPSK, BPSK) : Ant0: External Antenna, 3.91dBi(Max.) Ant1: External Antenna, 4.5dBi(Max.) Ant2: External Antenna, 4.16dBi(Max.) : 54700-5725MHz : 11 Channels for 20MHz bandwidth(5500MHz-5700MHz) 5 Channels for 40MHz bandwidth(5510MHz-5670MHz) 2 Channels for 80MHz bandwidth(5530MHz, 5610MHz) 1 channels for 160MHz bandwidth(5570MHz) : IEEE 802.11a: OFDM (64QAM, 16QAM, QPSK, BPSK) IEEE 802.11n: OFDM (64QAM, 16QAM, QPSK, BPSK) IEEE 802.11ac: OFDM (256QAM, 64QAM, 16QAM, QPSK, BPSK) IEEE 802.11ax: OFDM (1024QAM, 256QAM, 64QAM, 16QAM, QPSK, BPSK) : Ant0: External Antenna, 4.29dBi(Max.) Ant1: External Antenna, 4.87dBi(Max.) Ant2: External Antenna, 4.24dBi(Max.) : : 5725MHz~5850MHz : 5 channels for 20MHz bandwidth(5745MHz~5825MHz) 2 channels for 40MHz bandwidth(5755MHz~5795MHz) 1 channels for 80MHz bandwidth(5775MHz) : IEEE 802.11a: OFDM (64QAM, 16QAM, QPSK, BPSK) IEEE 802.11n: OFDM (64QAM, 16QAM, QPSK, BPSK) IEEE 802.11ac: OFDM (256QAM, 64QAM, 16QAM, QPSK, BPSK) IEEE 802.11ax: OFDM (1024QAM, 256QAM, 64QAM, 16QAM, QPSK, BPSK) : Ant0: External Antenna, 3.92dBi(Max.) Ant1: External Antenna, 4.57dBi(Max.) Ant2: External Antenna, 4.3dBi(Max.) Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 8 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED 1.2. Host System Configuration List and Details Manufacturer DEE VAN ENTERPRISE CO., LTD Description AC ADAPTER Model DSA-12PF11-12 FUS 120100 Serial Number Certificate --- FCC 1.3. External I/O Cable I/O Port Description LAN Port DC Input Port Quantity 4 1 Cable N/A N/A 1.4. Description of Test Facility NVLAP Accreditation Code is 600167-0. FCC Designation Number is CN5024. CAB identifier is CN0071. CNAS Registration Number is L4595. Test Firm Registration Number: 254912. The 3m-Semi anechoic test site fulfils CISPR 16-1-4 according to ANSI C63.4:2014 and CISPR 16-1-4:2010 SVSWR requirement for radiated emission above 1GHz. 1.5. Statement of the Measurement Uncertainty The data and results referenced in this document are true and accurate. The reader is cautioned that there may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was calculated for all measurements listed in this test report acc. To CISPR 16 4 "Specification for radio disturbance and immunity measuring apparatus and methods Part 4: Uncertainty in EMC Measurements" and is documented in the LCS quality system acc. To DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar to that tested may result in additional deviation. The manufacturer has the sole responsibility of continued compliance of the device. 1.6. Measurement Uncertainty No. Item Uncertainty 1 DFS Threshold (radiated) ±1.50dB 2 DFS Threshold (conducted) ±1.45dB 3 Temperature ±0.5°C 4 Humidity ±2% (1). This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2. Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 9 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED 1.7. Description of Test Modes The EUT has been tested under operating condition. Worst-Case data rates were utilized from preliminary testing of the Chipset, worst-case data rates used during the testing are as follows: IEEE 802.11a Mode: 6 Mbps, OFDM. IEEE 802.11n HT20 Mode: MCS0, OFDM. IEEE 802.11n HT40 Mode: MCS0, OFDM. IEEE 802.11ac VHT20 Mode: MCS0 IEEE 802.11ac VHT40 Mode: MCS0, OFDM. IEEE 802.11ac VHT80 Mode: MCS0, OFDM. IEEE 802.11ac VHT160 Mode: MCS0, OFDM. IEEE 802.11 ax HEW 20 IEEE 802.11 ax HEW 40 IEEE 802.11 ax HEW 80 IEEE 802.11 ax HEW 160 802.11ax HEW20_Nss1,(MCS0),RU 26,#RU 0 802.11ax HEW20_Nss1,(MCS0),RU 26,#RU 4 802.11ax HEW20_Nss1,(MCS0),RU 26,#RU 8 802.11ax HEW20_Nss1,(MCS0),RU 52,#RU 37 802.11ax HEW20_Nss1,(MCS0),RU 52,#RU 40 802.11ax HEW20_Nss1,(MCS0),RU 106,#RU 53 802.11ax HEW20_Nss1,(MCS0),RU 106,#RU 54 802.11ax HEW40_Nss1,(MCS0),RU 242,#RU 61 802.11ax HEW40_Nss1,(MCS0),RU 242,#RU 62 802.11ax HEW80_Nss1,(MCS0),RU 484,#RU 65 802.11ax HEW80_Nss1,(MCS0),RU 484,#RU 66 802.11ax HEW160_Nss1,(MCS0),RU 996,#RU 67 802.11ax HEW160_Nss1,(MCS0),RU 996,#RU 195 Antenna & Bandwidth Antenna Chain0 (Ant0) Bandwidth Mode 20 M Hz 40 M Hz 80 MH z 160 MH z IEEE 802.11a IEEE 802.11n IEEE 802.11ac IEEE 802.11ax Chain1 (Ant1) 20M Hz 40 MH z 80 MH z 160 MHz Chain1 (Ant2) 20 40 80 16 MH MH MH 0M z z z Hz Simultane ously / Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 10 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED 1.8. Channel List and Frequency U-NI-1 Frequency Band Channel No. Frequency (MHz) Channel No. Frequency (MHz) 36 5180 44 5220 5150~5250MHz 38 40 5190 5200 46 48 5230 5240 42 5210 50 5250 For IEEE 802.11a/n HT20/ac VHT20/ax HE20, Channel 36, 40 and 48 were tested. For IEEE 802.11n HT40/ac VHT40/ax HE40, Channel 38 and 46 were tested. For IEEE 802.11ac VHT80/ ax HE80, Channel 42 was tested. For IEEE 802.11ac VHT160/ ax HE160, Channel 50 was tested. U-NI-2A Frequency Band Channel No. Frequency (MHz) Channel No. Frequency (MHz) 50 5250 58 5290 5250-5350MHz 52 54 5260 5270 60 62 5300 5310 56 5280 64 5320 For IEEE 802.11a/n HT20/ac VHT20/ax HE20, Channel 52, 60 and 64 were tested. For IEEE 802.11n HT40/ac VHT40/ax HE40, Channel 54 and 62 were tested. For IEEE 802.11ac VHT80/ax HE80, Channel 58 was tested. For IEEE 802.11ac VHT160/ax HE160, Channel 50 was tested. U-NI-2C Frequency Band Channel No. Frequency (MHz) Channel No. Frequency (MHz) 100 5500 118 5590 102 5510 120 5600 104 5520 122 5610 106 5530 124 5620 5470-5725MHz 108 110 5540 5550 126 128 5630 5640 112 5560 132 5660 114 5570 134 5670 116 5580 136 5680 -- -- 140 5700 For IEEE 802.11a/n HT20/ac VHT20/ax HE20, Channel 100, 116 and 140 were tested. For IEEE 802.11n HT40/ac VHT40/ax HE40, Channel 102, 110 and 134 were tested. For IEEE 802.11ac VHT80/ax E80, Channel 106, 122 were tested. For IEEE 802.11ac VHT160/ax HE160, Channel 114 were tested. Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 11 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED 1.9. Conduted Output Power and EIRP Mode Frequency Band (MHz) IEEE 802.11a IEEE 802.11n HT20 IEEE 802.11ac VHT20 IEEE 802.11ax VHT20 IEEE 802.11n HT40 IEEE 802.11ac VHT40 IEEE 802.11ax VHT40 IEEE 802.11ac VHT80 IEEE 802.11ax VHT80 IEEE 802.11ac VHT160 IEEE 802.11ax VHT160 IEEE 802.11ac VHT160 IEEE 802.11ax VHT160 5260 5320 5500 5700 5260 5320 5500 5700 5260 5320 5500 5700 5260 5320 5500 5700 5270 5310 5510 5670 5270 5310 5510 5670 5270 5310 5510 5670 5290 5530-5610 5290 5530-5610 5250 5250 5570 5570 Maximum Conducted Output Power (dBm) 19.36 20.24 17.44 16.9 17.84 16.96 17.92 16.79 17.61 16.98 17.87 17.08 17.92 17.01 16.13 17.23 16.96 17.52 10.19 10.68 9.53 8.84 Antenna Gain (dBi) 4.5 4.29 8.97 9.24 8.97 9.24 8.97 9.24 8.97 9.24 8.97 9.24 8.97 9.24 8.97 9.24 8.97 9.24 8.97 Maximum EIRP Maximum EIRP (dBm) (mW) 23.86 24.53 26.41 26.14 26.81 26.2 26.89 26.03 26.58 26.22 26.84 26.32 26.89 26.25 25.10 26.47 25.93 26.76 19.16 243.22 283.79 437.52 411.15 479.73 416.87 488.65 400.87 454.99 418.79 483.06 428.55 488.65 421.70 323.59 443.61 391.74 474.24 82.41 8.97 19.65 92.26 9.24 18.77 75.34 9.24 18.08 64.27 Remark: 1. A TPC mechanism is not required for systems with an e.i.r.p. of less than 500 mW; Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 12 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED 2. TEST METHODOLOGY This report has been prepared to demonstrate compliance with the requirements for Dynamic Frequency Selection (DFS) as stated in FCC CFR 47 PART 15E(15.407). Testing was performed in accordance with the measurement procedure described in FCC KDB 905462 D02 v02 3. SYSTEM TEST CONFIGURATION 3.1. EUT Exercise Software The system was configured for testing in a continuous transmits condition and change test channels by software provided by application. 3.2. Special Accessories N/A 3.3. Block Diagram/Schematics Please refer to the related document 3.4. Equipment Modifications Shenzhen LCS Compliance Testing Laboratory Ltd. has not done any modification on the EUT. 3.5. Test Setup Figure 7-1. Test Setup Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 13 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED 4. SUMMARY OF TEST RESULTS Applied Standard: FCC CFR 47 PART 15.407 Operational Mode Requirement Master Client with radar Client without detection radar detection Non-Occupancy Period Required Required Not required DFS Detection Threshold Required Required Not required Channel Availability Check Time Required Not required Not required Channel Closing Transmission Time Required Required Required Channel Move Time Required Required Required U-NII Detection Bandwidth Required Required Not required RESULTS Pass Pass Pass Pass Pass Pass Note:The device belongs to Master with radar detection categorys. Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 14 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED 5. DESCRIPTION OF DYNAMIC FREQUENCY SELECTION TEST 5.1. Requirements Per FCC KDB 905462 D02 UNII DFS Compliance Procedures New Rules v02 the following are the requirements for Master Devices: (a) The Master Device will use DFS in order to detect Radar Waveforms with received signal strength above the DFS Detection Threshold in the 5250 ~ 5350 MHz and 5470 ~ 5725 MHz bands. DFS is not required in the 5150 ~ 5250 MHz or 5725 ~ 5825 MHz bands. (b) Before initiating a network on a Channel, the Master Device will perform a Channel Availability Check for a specified time duration (Channel Availability Check Time) to ensure that there is no radar system operating on the Channel, using DFS described under subsection a) above. (c) The Master Device initiates a U-NII network by transmitting control signals that will enable other U-NII devices to Associate with the Master Device. (d) During normal operation, the Master Device will monitor the Channel (In-Service Monitoring) to ensure that there is no radar system operating on the Channel, using DFS described under a). (e) If the Master Device has detected a Radar Waveform during In-Service Monitoring as described under d), the Operating Channel of the U-NII network is no longer an Available Channel. The Master Device will instruct all associated Client Device(s) to stop transmitting on this Channel within the Channel Move Time. The transmissions during the Channel Move Time will be limited to the Channel Closing Transmission Time. (f) Once the Master Device has detected a Radar Waveform it will not utilize the Channel for the duration of the Non-Occupancy Period. (g) If the Master Device delegates the In-Service Monitoring to a Client Device, then the combination will be tested to the requirements described under d) through f) above Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 15 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED 5.2. RESPONSE REQUIREMENTS Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 16 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED 6. DFS DETECTION THRESHOLD VALUES The DFS detection thresholds are defined for Master devices and Client Devices with In-service monitoring. These detection thresholds are listed in the following table. Maximum Transmit Power EIRP 200 milliwatt EIRP< 200 milliwatt and Power pectral < 10 dBm/MHz EIRP<200 milliwatt that do not meet the power spectral density requirement Value (See Notes 1 and 2) -64 dBm -62 dBm -64 dBm Note 1: This is the level at the input of the receiver assuming a 0 dBi receive antenna. Note 2: Throughout these test procedures an additional 1 dB has been added to the amplitude of the test transmission waveforms to account for variations in measurement equipment. This will ensure that the test signal is at or above the detection threshold level to trigger a DFS response. Note 3: EIRP is based on the highest antenna. For MIMO devices refer to KDB Publication 662911 D01. 7. DFS TEST SIGNALS This section provides the parameters for required test waveforms, minimum percentage of successful detections, and the minimum number of trials that must be used for determining DFS conformance. Step intervals of 0.1 microsecond for Pulse Width, 1 microsecond for PRI, 1 MHz for chirp width and 1 for the number of pulses will be utilized for the random determination of specific test waveforms. Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 17 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Table 5 Short Pulse Radar Test Waveforms A minimum of 30 unique waveforms are required for each of the Short Pulse Radar Types 2 through 4. If more than 30 waveforms are used for Short Pulse Radar Types 2 through 4, then each additional waveform must also be unique and not repeated from the previous waveforms. If more than 30 waveforms are used for Short Pulse Radar Type 1, then each additional waveform is generated with Test B and must also be unique and not repeated from the previous waveforms in Tests A or B. Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 18 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Table 6 Long Pulse Radar Test Waveform The parameters for this waveform are randomly chosen. Thirty unique waveforms are required for the Long Pulse Radar Type waveforms. If more than 30 waveforms are used for the Long Pulse Radar Type waveforms, then each additional waveform must also be unique and not repeated from the previous waveforms. Each waveform is defined as follows: 1) The transmission period for the Long Pulse Radar test signal is 12 seconds. 2) There are a total of 8 to 20 Bursts in the 12 second period, with the number of Bursts being randomly chosen. This number is Burst Count. 3) Each Burst consists of 1 to 3 pulses, with the number of pulses being randomly chosen. Each Burst within the 12 second sequence may have a different number of pulses. 4) The pulse width is between 50 and 100 microseconds, with the pulse width being randomly chosen. Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 19 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Each pulse within a Burst will have the same pulse width. Pulses in different Bursts may have different pulse widths. 5) Each pulse has a linear frequency modulated chirp between 5 and 20 MHz, with the chirp width being randomly chosen. Each pulse within a transmission period will have the same chirp width. The chirp is centered on the pulse. For example, with a radar frequency of 5300 MHz and a 20 MHz chirped signal, the chirp starts at 5290 MHz and ends at 5310 MHz. 6) If more than one pulse is present in a Burst, the time between the pulses will be between 1000 and 2000 microseconds, with the time being randomly chosen. If three pulses are present in a Burst, the random time interval between the first and second pulses is chosen independently of the random time interval between the second and third pulses. 7) The 12 second transmission period is divided into even intervals. The number of intervals is equal to Burst Count. Each interval is of length (12,000,000 / Burst Count) microseconds. Each interval contains one Burst. The start time for the Burst, relative to the beginning of the interval, is between 1 and [(12,000,000 / Burst Count) (Total Burst Length) + (One Random PRI Interval)] microseconds, with the start time being randomly chosen. The step interval for the start time is 1 microsecond. The start time for each Burst is chosen randomly. A representative example of a Long Pulse Radar Type waveform: 1) The total test waveform length is 12 seconds. 2) Eight (8) Bursts are randomly generated for the Burst Count. 3) Burst 1 has 2 randomly generated pulses. 4) The pulse width (for both pulses) is randomly selected to be 75 microseconds. 5) The PRI is randomly selected to be at 1213 microseconds. 6) Bursts 2 through 8 are generated using steps 3 5. 7) Each Burst is contained in even intervals of 1,500,000 microseconds. The starting location for Pulse 1, Burst 1 is randomly generated (1 to 1,500,000 minus the total Burst 1 length + 1 random PRI interval) at the 325,001 microsecond step. Bursts 2 through 8 randomly fall in successive 1,500,000 microsecond intervals (i.e. Burst 2 falls in the 1,500,001 3,000,000 microsecond range). Table 7 Frequency Hopping Radar Test Waveform For the Frequency Hopping Radar Type, the same Burst parameters are used for each waveform. The hopping sequence is different for each waveform and a 100-length segment is selected from the hopping sequence defined by the following algorithm: The first frequency in a hopping sequence is selected randomly from the group of 475 integer frequencies from 5250 5724 MHz. Next, the frequency that was just chosen is removed from the group and a frequency is randomly selected from the remaining 474 frequencies in the group. This process continues until all 475 frequencies are chosen for the set. For selection of a random frequency, the frequencies remaining within the group are always treated as equally likely. Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 20 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Manufacturer's Statement Regarding Uniform Channel Spreading The end product implements an automatic channel selection feature at startup such that operation commences on channels distributed across the entire set of allowed 5GHz channels. This feature will ensure uniform spreading is achieved while avoiding non-allowed channels due to prior radar events. TEST AND MEASUREMENT SYSTEM System Overview The measurement system is based on a conducted test method. The short pulse and long pulse signal generating system utilizes the NTIA software and the same manufacturer / model Vector Signal Generator as the NTIA. The hopping signal generating system utilizes the simulated hopping method. The software selects waveform parameters from within the bounds of the signal type on a random basis using uniform distribution. The short pulse types 2, 3 and 4, and the long pulse type 5 parameters are randomized at run-time. The hopping type 6 pulse parameters are fixed while the hopping sequence is based on the August 2005 NTIA Hopping Frequency List, with the initial starting point randomized at run-time. The signal monitoring equipment consists of a spectrum analyzer with the capacity to display 8192 bins on the horizontal axis. A time-domain resolution of 2 msec / bin is achievable with a 16 second sweep time, meeting the 10 second short pulse reporting criteria. The aggregate ON time is calculated by multiplying the number of bins above a threshold during a particular observation period by the dwell time per bin, with the analyzer set to peak detection and max hold. A time-domain resolution of 3 msec / bin is achievable with a 24 second sweep time, meeting the 22 second long pulse reporting criteria and allowing a minimum of 10 seconds after the end of the long pulse waveform. Frequency Hopping Signal Generation The hopping burst generator is a High Speed Digital I/O card plugged into the control computer. This card utilizes an independent hardware clock reference therefore the output pulse timing is unaffected by host computer operating system latency times. The software selects the hopping sequence as a 100-length segment of the August 2005 NTIA hopping frequency list. This list contains 274 unique pseudorandom sequences. Each such sequence contains 475 frequencies ordered on a random without replacement basis. Each successive trial uses a contiguous 100length segment from within each successive 475-length sequence in the list. The initial starting point within the list is randomized at run-time such that the first 100-length segment is entirely contained within the first 475-length sequence. The starting point of each successive trial is incremented by 475. Each frequency in the 100-length segment is compared to the boundaries of the EUT Detection Bandwidth and the software creates a hopping burst pattern in accordance with Section 7.4.1.3 Method #2 Simulated Frequency Hopping Radar Waveform Generating Subsystem of FCC 06-96 APPENDIX. The frequency of the signal generator is incremented in 1 MHz steps from FL to FH for each successive trial. This incremental sequence is repeated as required to generate a minimum of 30 total trials and to maintain a uniform frequency distribution over the entire Detection Bandwidth. Conducted Method System Block Diagram Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 21 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Measurement System Frequency Reference Lock the signal generator and the spectrum analyzer to the same reference source as follows: Connect the 10 MHz OUT (SWITCHED) on the spectrum analyzer to the 10 MHz IN on the signal generator and set the spectrum analyzer 10 MHz Out to On. System Calibration Connect the spectrum analyzer to the test system in place of the master device. Set the signal generator to CW mode. Adjust the amplitude of the signal generator to yield a measured level of 62 dBm on the spectrum analyzer. Without changing any of the instrument settings, reconnect the spectrum analyzer to the Common port of the Spectrum Analyzer Combiner/Divider and connect a 50 ohm load to the Master Device port of the test system. Measure the amplitude and calculate the difference from 62 dBm. Adjust the Reference Level Offset of the spectrum analyzer to this difference. Confirm that the signal is displayed at 62 dBm. Readjust the RBW and VBW to 3 MHz, set the span to 10 MHz, and confirm that the signal is still displayed at 62 dBm. The spectrum analyzer displays the level of the signal generator as received at the antenna ports of the Master Device. The interference detection threshold may be varied from the calibrated value of 62 dBm and the spectrum analyzer will still indicate the level as received by the Master Device. Set the signal generator to produce a radar waveform, trigger a burst manually and measure the level on the spectrum analyzer. Readjust the amplitude of the signal generator as required so that the peak level of the waveform is at a displayed level equal to the required or desired interference detection threshold. Separate signal generator amplitude settings are determined as required for each radar type. Interference Detection Threshold Adjustment Download the applicable radar waveforms to the signal generator. Select the radar waveform, trigger a burst manually and measure the amplitude on the spectrum analyzer. Readjust the amplitude of the signal generator as required so that the peak level of the waveform is at a displayed level equal to the required or desired interference detection threshold. Separate signal generator amplitude settings are determined as required for each radar type. Adjustment Of Displayed Traffic Level Establish a link between the Master and Slave, adjusting the Link Step Attenuator as needed to provide a suitable received level at the Master and Slave devices. Stream the video test file to generate WLAN traffic. Confirm that the WLAN traffic level, as displayed on the spectrum analyzer, is at lower amplitude than the radar detection threshold. Confirm that the displayed traffic is from the Master Device. For Master Device testing confirm that the displayed traffic does not include Slave Device traffic. For Slave Device testing confirm that the displayed traffic does not include Master Device traffic. If a different setting of the Master Step Attenuator is required to meet the above conditions, perform a new System Calibration for the new Master Step Attenuator setting. Test Setup Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 22 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED 8. TEST RESULT 8.1. CHANNEL LOADING Test Mode 802.11ax-HE20 Test Frequency 5500 Packet Ratio 19.81% Requirement Ratio 17% Test resuelt PASS 802.11ax-HE40 5510 19.65% 17% PASS 802.11ax-HE80 5530 19.27% 17% PASS 802.11ax-HE160 5570 19.54% 17% PASS Note: System testing was performed with the designated iperf test file. This file is used by IP and Frame based systems for loading the test channel during the In-service compliance testing of the U-NII device. Packet ratio = Time On / (Time On + Off Time). 802.11ax-HE20 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 23 of 227 FCC ID: 2APRGRT02 802.11ax-HE40 Report No.: LCSA031723030ED 802.11ax-HE80 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 24 of 227 FCC ID: 2APRGRT02 802.11ax-HE160 Report No.: LCSA031723030ED 8.2. PLOTS OF RADAR WAVEFORMS Radar Singal 0 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 25 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Radar Singal 1A Radar Singal 1B Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 26 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Radar Singal 2 Radar Singal 3 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 27 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Radar Singal 4 Radar Singal 5 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 28 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Radar Singal 6 Trial ID 0 1 2 3 4 5 6 7 8 9 10 11 Radar Type Type 0 Type 0 Type 0 Type 0 Type 0 Type 0 Type 0 Type 0 Type 0 Type 0 Type 0 Type 0 Radar Singal 0 Pulse Width (us) PRI (us) 1 1426 1 1426 1 1426 1 1426 1 1426 1 1426 1 1426 1 1426 1 1426 1 1426 1 1426 1 1426 Number of Pulses 16 16 16 16 16 16 16 16 16 16 16 16 Waveform Legth (us) 25702 25702 25702 25702 25702 25702 25702 25702 25702 25702 25702 25702 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 29 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED 12 Type 0 13 Type 0 14 Type 0 15 Type 0 16 Type 0 17 Type 0 18 Type 0 19 Type 0 20 Type 0 21 Type 0 22 Type 0 23 Type 0 24 Type 0 25 Type 0 26 Type 0 27 Type 0 28 Type 0 29 Type 0 1 1426 16 1 1426 16 1 1426 16 1 1426 16 1 1426 16 1 1426 16 1 1426 16 1 1426 16 1 1426 16 1 1426 16 1 1426 16 1 1426 16 1 1426 16 1 1426 16 1 1426 16 1 1426 16 1 1426 16 1 1426 16 25702 25702 25702 25702 25702 25702 25702 25702 25702 25702 25702 25702 25702 25702 25702 25702 25702 25702 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 30 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Trial ID 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 Radar Type Type A Type A Type A Type A Type A Type A Type A Type A Type A Type A Type A Type A Type A Type A Type A Type B Type B Type B Type B Type B Type B Type B Type B Type B Type B Type B Type B Type B Type B Type B Pulse Width (us) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Radar Singal 1 Number of PRI (us) Pulses 935 57 695 76 615 86 535 99 875 61 3063 18 635 83 915 58 835 63 855 62 795 67 715 74 575 92 595 89 555 95 2533 21 963 55 824 64 2498 22 2592 21 1111 48 1299 41 3042 18 1621 33 2875 19 1024 52 2482 22 1597 33 1169 46 1174 45 Waveform Legth (us) 53463 53045 53145 53259 53555 55185 52951 53241 52791 53193 53463 53129 53173 53219 53007 53253 53127 52925 55019 54492 53469 53379 54807 53589 54679 53401 54667 52797 53909 52962 Pulse Repection Frequency (Pulses Per Second) 1066.0 1432.5 1617.9 1858.6 1138.8 326.0 1567.2 1089.2 1193.2 1165.6 1253.0 1392.6 1730.0 1672.0 1792.0 Pulse Repection Interval (Microseconds) 935 695 615 535 875 323 1564 1086 1190 1162 1250 1390 1727 1669 1789 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 31 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Trial ID 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 Radar Type Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Radar Singal 2 Pulse Width (us) PRI (us) 3.2 176 1.1 204 2.1 227 4.8 197 3.9 211 2.9 219 3.2 201 2.5 189 3.1 161 1.2 153 3.9 207 4.6 198 3.2 159 2.2 194 4.5 160 3 200 5 165 2.4 214 2.9 188 2.3 163 3.7 147 2.2 173 4.9 192 2.9 199 2.5 175 1.1 203 3.8 152 4.8 154 2.4 221 4.2 156 Number of Pulses 24 21 22 21 26 24 21 23 26 21 25 27 24 23 26 24 21 23 24 23 26 23 27 24 23 21 26 27 23 26 Waveform Legth (us) 4651 4758 5517 5797 5989 5769 5301 4797 4261 3585 5667 5826 4209 4922 4724 5275 4869 5422 4963 4147 4047 4397 5652 5249 4447 4735 4182 4550 5597 4449 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 32 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Trial ID 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 Radar Type Type 3 Type 3 Type 3 Type 3 Type 3 Type 3 Type 3 Type 3 Type 3 Type 3 Type 3 Type 3 Type 3 Type 3 Type 3 Type 3 Type 3 Type 3 Type 3 Type 3 Type 3 Type 3 Type 3 Type 3 Type 3 Type 3 Type 3 Type 3 Type 3 Type 3 Radar Singal 3 Pulse Width (us) PRI (us) 8.1 352 5.9 484 7.0 341 9.6 285 8.8 227 7.8 429 8.2 204 7.3 440 8.0 436 6.1 220 8.7 205 9.4 460 8.2 438 7.0 320 9.3 294 7.8 409 9.9 321 7.2 268 7.8 346 7.1 406 8.5 370 7.2 251 9.8 271 7.9 275 7.4 314 6.0 257 8.6 208 9.6 269 7.2 261 9.0 281 Number of Pulses 14 13 13 15 15 14 14 14 14 13 15 15 14 13 15 14 15 14 14 13 15 13 15 14 14 13 15 15 14 15 Waveform Legth (us) 6032 7789 5501 5181 4137 7341 3516 7528 7460 3565 3741 8331 7494 5165 5343 7001 5829 4604 5930 6541 6711 4061 5929 4723 5386 4157 3795 4893 4485 5109 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 33 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Trial ID 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 Radar Type Type 4 Type 4 Type 4 Type 4 Type 4 Type 4 Type 4 Type 4 Type 4 Type 4 Type 4 Type 4 Type 4 Type 4 Type 4 Type 4 Type 4 Type 4 Type 4 Type 4 Type 4 Type 4 Type 4 Type 4 Type 4 Type 4 Type 4 Type 4 Type 4 Type 4 Radar Singal 4 Pulse Width (us) PRI (us) 15.9 352 11.1 486 13.4 363 19.2 287 17.3 232 15.1 431 15.8 206 14.2 462 15.7 438 11.3 222 17.3 237 18.9 462 15.9 445 13.7 322 18.9 296 15.4 311 19.8 323 14.1 260 15.1 348 13.7 408 17.0 362 13.6 253 19.6 233 15.2 277 14.4 316 11.1 265 17.2 210 19.1 261 14.0 263 18.0 282 Number of Pulses 14 11 12 15 14 14 13 12 13 111 14 15 13 14 15 13 11 12 13 30 14 14 15 13 12 11 13 15 11 14 Waveform Legth (us) 4945 5819 4447 4583 3425 6023 2873 5734 6120 2651 3095 7383 6149 4174 4727 5743 5159 3498 4861 5292 5570 3277 4359 3867 4096 3095 3140 4327 3407 4235 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 34 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Radar Singal 5_5530MHz Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 35 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 36 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 37 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 38 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 39 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 40 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 41 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 42 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 43 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 44 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 45 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 46 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 47 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 48 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 49 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 50 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 51 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 52 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 53 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 54 of 227 FCC ID: 2APRGRT02 Radar Singal 5_5540MHz Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 55 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 56 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 57 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 58 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 59 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 60 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 61 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 62 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 63 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 64 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 65 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 66 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 67 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 68 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 69 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 70 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 71 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 72 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 73 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 74 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 75 of 227 FCC ID: 2APRGRT02 Radar Singal 5_5550MHz Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 76 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 77 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 78 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 79 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 80 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 81 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 82 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 83 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 84 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 85 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 86 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 87 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 88 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 89 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 90 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 91 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 92 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 93 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 94 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 95 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 96 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED Trial ID 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 Radar Type Type 6 Type 6 Type 6 Type 6 Type 6 Type 6 Type 6 Type 6 Type 6 Type 6 Type 6 Type 6 Type 6 Type 6 Type 6 Type 6 Type 6 Type 6 Type 6 Type 6 Type 6 Type 6 Type 6 Type 6 Type 6 Type 6 Type 6 Type 6 Type 6 Type 6 Radar Singal 6 Pulse PRI (us) Width (us) Number of Pulses Waveform Legth (us) 1 334 9 0.3336 1 334 9 0.3336 1 334 9 0.3336 1 334 9 0.3336 1 334 9 0.3336 1 334 9 0.3336 1 334 9 0.3336 1 334 9 0.3336 1 334 9 0.3336 1 334 9 0.3336 1 334 9 0.3336 1 334 9 0.3336 1 334 9 0.3336 1 334 9 0.3336 1 334 9 0.3336 1 334 9 0.3336 1 334 9 0.3336 1 334 9 0.3336 1 334 9 0.3336 1 334 9 0.3336 1 334 9 0.3336 1 334 9 0.3336 1 334 9 0.3336 1 334 9 0.3336 1 334 9 0.3336 1 334 9 0.3336 1 334 9 0.3336 1 334 9 0.3336 1 334 9 0.3336 1 334 9 0.3336 Pulse Repection Frequency (Pulses Per Second) 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 Pulse Repection Interval (Microseconds) 15 12 15 18 10 13 12 15 14 16 13 22 21 15 14 15 12 15 18 10 13 12 15 14 16 13 22 21 15 14 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 97 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED 7.3. CHANNEL AVAILABILITY CHECK TIME The EUT shall perform a Channel Availability Check to ensure that there is no radar operating on the channel. After power-up sequence, receive at least 1 minute on the intended operating frequency Initial Channel Availability Check Time (802.11ax-HE160 mode - 5250MHz) Note: The EUT does not transmit any beacon or data transmissions until at least 1 minute after the completion of the power-on cycle (34.61sec). Initial beacons/data transmissions are indicated by marker 1 (94.61 sec). Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 98 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED 7.4. Radar Burst at the Beginning of the Channel Availability Check Time Measurement Beginning of the Channel Availability Check Time (802.11ax-160 mode - 5250MHz) In beginning of the Channel Availability Check (CAC) Time, radar is detected on this channel, select another intended channel and perform a CAC on that channel. Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 99 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED 7.5. Radar Burst at the End of the Channel Availability Check Time Measurement In the end of Channel Availability Check (CAC) Time, radar is detected on this channel, select another intended channel and perform a CAC on that channel. End of the Channel Availability Check Time (802.11ax-HE160 mode - 5250MHz) Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity Page 100 of 227 FCC ID: 2APRGRT02 Report No.: LCSA031723030ED 7.6. In-Service Monitoring for Channel Move Time, Channel Closing Transmission Time and Non-Occupancy Period Measurement The EUT has In-Service Monitoring function to continuously monitor the radar signals. If the radar is detected, must leave the channel (Shutdown). The Channel Move Time to cease all transmissions on the current channel upon detection of a Radar Waveform above the DFS Detection Threshold within 10 sec. The total duration of Channel Closing Transmission Time is 260ms, consisting of data signals and the aggregate of control signals, by a U-NII device during the Channel Move Time. The Non-Occupancy Period time is 30 minute during which a Channel will not be utilized after a Radar Waveform is detected on that Channel. Mode Frequen cy (MHz) Channel Move Time (s) Limit Channel Move Time (s) Close Transmission Time (s) Limit Close Transmission Time (s) Close Transmission Time after 200ms(s) Limit Close Transmission Time after 200ms (s) 802.11ax-HE160 5570 0.6489 10 0.0084 0.26 0.004 0.06 Verdict pass Channel Move Time and Channel Closing Transmission Time Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticityMicrosoft Word 2010